FIRE MANAGEMENTPRODUCTS
TRACK 1000
TECHNICAL PRODUCT GUIDE
Effective September 1, 2014
FAS TRACK 1000™
ARCHITECT SPECIFIED CONTRACTOR PREFERRED
RE-THINK FIRE CAULKING:FAS Track 1000 requires NO fire sealant or fire spray when used on solid concrete construction or when used with spray applied fireproofing at fluted pan decks for 1 and 2 hour fire rated walls.
FAS Track costs up to 25% LESS than other brands claiming the same type of fire/acoustical/sound abatement.
With FAS Track 1000 you are guaranteed that once installed the intumescent tape will not wear off, tear off, or fall off, making it the most reliable intumescent track on the market.
On fluted deck applications mineral wool can be replaced with spray applied fireproofing, this assembly will not require any additional fire spray or fire caulking
CODE COMPLIANCEFAS Track 1000 meets current building codes and its unique profile design provides industry solutions for meeting deflection requirements where other materials or systems are restricted by design, compressibility, elasticity, or bond strength characteristics.
FAS Track 1000 has no restrictions providing 100% unencumbered movement. FAS Track 1000 has been tested for compliance with Section 713.3 of the 2009 and 2012 IBC and 2010 CBC and is listed with UL Underwriters Laboratories in accordance with:
n UL 2079: Tests for Fire Resistance of Building Joint Systems.
n ASTM E 1966: Standard Test Method of Fire Tests of Firestop Systems.
n ULC S115-M95: Standard Method of Fire Tests of Firestop Systems.
n ICC-ESR 2012 *Pending
n ASTM E-119 Standard Test Methods for Fire Tests of Building Construction and Materials
n Sound tested in accordance to ASTM E90-09
SEISMIC REQUIREMENTSFAS Track 1000 is approved for Class III cycling requirements, 500 cycles at 30 cycles per minute,meeting seismic building codes requirements. The class III movement provides design advantages over mastic reliant systems which are currently limited to class II (wind sway) capabilities of 500 cycles at 10 cycles per minute.
AIR LEAKAGE RATINGAir leakage tests conducted for compliance with Section 713.6 of the 2009 and 2012 IBC and 2010 CBC are witnessed by UL on conditions using FAS Track as the joint treatment established L-Ratings of less than 1 CFM per lineal foot. Any rating below 1 CFM is also considered the best possible L-Rating. This is achieved with the FAS Track 1000 profile which provides a consistent seal against the drywall.
TECHNICAL ASSISTANCEFor technical questions and assistance please call 1.800.775.2362 or 1.800.416.2278. Email [email protected] or visit our website at www.cemcosteel.com
SOUND BENEFITS: Whether the protection you need is Fire, Air (Smoke), or Sound FAS Track 1000 is all the protection you need in one easy application.
Sound tests were performed at Western Electro-Acoustic Laboratory in Southern California to prove that the FAS Track 1000 profile will maintain maximum STC ratings without secondary acoustic sealant applications. In fact several sound tests were conducted with a ½” to ¾” open joint at the head-of-wall and with a sealed head-of-wall joint on the same wall assembly. Both open and closed joints rendered the exact same STC rating proving that no sound is lost through the open head of wall joint.
Sound tests were also conducted on a 2-1/2” wide stud double wall a.k.a. plumbing-wall or chase-wall with a single layer on both sides rendered an STC rating of 60. Adding one layer to only one side of the double wall increased the STC rating to 63.
The UBC requires Sound Transmission Class (STC) ratings and Impact Insulation Class (IIC) ratings for dwelling units, which include hotels, motels, apartments, condominiums, dormitories, and monasteries to be at a minimum 50 STC or IIC rating. Sound ratings can be greatly reduced through sound flanking paths. To reduce flanking paths drywall should be sealed tight to the framing member around the perimeter.
BW-S-0024
FAS Track 1000
WW-D-0104
Bottom of Wall Static Joint Assembly Rating 2 Hour
HW-D-0624 (Option 1)
Vertical Wall Tie Into Concrete Slab Assembly Rating 2 Hour
FAS TRACK 1000 DETAILS ¾” JOINT PROTECTION FOR 1* AND 2 HOUR FIRE RATED WALLS
CEMCOFAS TRACK 1000BT
5/8" TYPE "X"DRYWALL
12" JOINT
PROTECTION
#8 x 1/2" FRAMINGSCREW
CONCRETE SLAB
METAL STUDBY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
DRYWALL SCREW
5/8" TYPE "X" DRYWALL
CONCRETE
METAL STUDBY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
CEMCOFAS TRACK DL 1000
“A”Track Member Width
(inch)Flange Size
(inch)Length
(ft)Steel Thickness
mils (gauge)
2 ½, 3 5/8, 4, 6 and 8 2” 10 33 (20)43 (18) 54 (16)
US Patent 8,640,415 B2
“A”Track Member Width
(inch)Flange Size
(inch)Length
(ft)Steel Thickness
mils (gauge)
2 ½, 3 5/8, 4,6 and 8 1 ¼” 10
30 (20) 43 (18) 54 (16)
US Patent 8,640,415 B2
FAS Track 1000 DL / FAS Track 1000 (BT)
HW-D-0554 CHASE WALL
#8 x 1/2" FRAMINGSCREWCEMCO FAS TRACK 1000
(TAPE ON FINISH SIDE ONLY)
5/8" TYPE "X"DRYWALL
METAL STUDSPACING BY DESIGN
CONCRETE SLAB
3/4" JOINTPROTECTION
DRYWALL SCREW1" LOWER THANTRACK LEG
FAS TRACK 1000
5/8" TYPE "X" DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
CONCRETE SLAB
METAL STUDBY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
“A”Track Member Width
(inch)Flange Size
(inch)Length
(ft)
Steel Thickness mils
(gauge)
2 ½, 3 5/8, 4, 6 and 8 2 ¾” 10 20, 18, 16
US Patent # 8,640,415,B2
*Single Layer of 5/8” type “X” Gypsum Panel For 1 Hour Fire Rating
Standard Chase Wall, Concrete Slab Assembly Rating 2 Hour
Concrete Slab Assembly Rating 2 Hour
FAS J-TRACK (SHAFT WALL) ¾” JOINT PROTECTION FOR 1* AND 2 HOUR FIRE RATED WALLSAdditional joint systems can be found @ www.cemcosteel.com
HW-D-0525 HW-D-0525 (2)
HW-D-0622 HW-D-0625
Shaft Wall, Directly Under Beam Assembly Rating 2 Hours
Additional UL Joint System for FAS J-Track can be found at www.cemcosteel.com
“A”
Track Member Width(inch)
Flange Size (inch)
Length(ft)
Steel Thickness mils (gauge)
2 ½, 4, and 6 1 ½” short leg 2 ½” long leg
10 33 20
US Patent #8,640,415 B2
HW-D-0653FAS J-Track
Shaft Wall, Concrete Slab Assembly Rating 2 Hours
Shaft Wall, Perpendicular To Fluted Deck Assembly Rating 2 Hours
Shaft Wall, Perpendicular To Fluted Deck Assembly Rating 2 Hours
CEMCO FASJ- TRACK
1" SHAFT LINER
MINERAL WOOL
CONCRETE SLAB
5/8" TYPE "X" DRYWALL
34" JOINT PROTECTION
CONCRETE SLABOR FLUTED METALDECK WITHCONCRETE FILL
STEEL BEAM
STRUCTURALFIREPROOFING(THICKNESS BY OTHERS)
EXPANDED METALLATH
1/2" x 20 GA. Z-BAR OR16 GA. CRC @ 16" O.C.
MINERAL WOOL ORSPRAY FIREPROOFING
CH STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
MINERAL WOOL
38" NOMINAL GAP
(3 4" JOINT PROTECTION)
CEMCO FAS J-TRACK
8"
Standard Shaft Wall, Parallel & Cantilever Under Beam Assembly Rating 2 Hours
WITH CONCRETE FILL
MINERAL WOOL
TYPICAL STEELFASTENERS BY DESIGN
RECTORSEALFLAMESAFE/BIOSTOPSPRAY OVER MINERALWOOL (12" OVERLAPMETAL) ON ONE SIDEONLY
CH STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
CEMCO FAS J-TRACK
38" NOMINAL GAP
(3 4" JOINT PROTECTION)
FLUTED METAL DECKWITH CONCRETE FILL
MINERAL WOOL
TYPICAL STEELFASTENERS BY DESIGN
CH STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
CEMCO FAS J-TRACK
38" NOMINAL GAP
(3 4" JOINT PROTECTION)
SPRAY FIREPROOFING
STEEL BEAM
MINERAL WOOL ORSPRAY FIREPROOFING
CONCRETE SLAB OR FLUTEDMETAL DECK WITH CONCRETE FILL
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
1/2" x 20 GA. Z-BAR OR16 GA. CRC @ 16" O.C.
CH STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
MINERAL WOOL
38" NOMINAL GAP
(34" JOINT PROTECTION)
CEMCO FAS J-TRACK
*Single Layer of 5/8” type “X” Gypsum Panel For 1 Hour Fire Rating
FAS Track 1000 Fluted Deck Details For 1* And 2 Hour Fire Rated Walls Additional joint systems can be found @ www.cemcosteel.com
HW-D-0620 (2)
HW-D-0620
HW-D-0550
HW-D-0652
Standard Wall, Parallel And Directly Under Fluted Deck Assembly Rating 2 Hour
HW-D-0514
Standard Wall, Perpendicular To Fluted Deck Assembly Rating 2 Hour
Standard Wall, Parallel & Offset Under Fluted Deck Assembly Rating 2 Hour
Standard Wall, Gypsum Wallboard Ceiling Assembly Rating 2 Hour
WITH CONCRETE
SPRAY FIREPROOFING
CEMCOFAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
38" NOMINAL GAP
(34" JOINT PROTECTION)
#8 x 1/2" FRAMING SCREW
METAL STUDBY DESIGN
SPACING BY DESIGN
5/8" TYPE "X"DRYWALL
#8 x 1/2" FRAMINGSCREW
3/4" JOINT PROTECTION
CEMCO FAS TRACK 1000
CONCRETE DECK
DRYWALL SCREW1" LOWER THANTRACK LEG
METAL STUDSPACING BY DESIGN
5/8" TYPE "X"DRYWALL
#8 x 1/2" FRAMINGSCREW
3/4" JOINT PROTECTION
CEMCO FAST RACK 1000
MINERAL WOOL
CONCRETE DECK
DRYWALL SCREW1" LOWER THANTRACK LEG
FASTENERS BY DESIGN CONCRETE SLAB
OPEN WEB TRUSS ORJOIST
FURRING CHANNEL @24" O.C.
58" TYPE "C" GYPSUM
WALLBOARD
CEMCOFAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
38" NOMINAL GAP
(34" JOINT PROTECTION)
#8 x 1/2" FRAMING SCREW
METAL STUDBY DESIGN
HW-D-0518
FLUTED METAL DECK WITHCONCRETE FILL
1/2" x 20 GA. Z-BAR OR16 GA. CRC BY DESIGN
5/8" TYPE"X" DRYWALL
FIREPROOFING ORMINERAL WOOL
3.4 EXPANDEDRIB LATH
METAL STUDBY DESIGN
STEEL BEAM
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
CEMCO FASTRACK 1000
TYPICAL STEELFASTENERS BY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
Standard Wall, Cantilevered Under Beam Assembly Rating 2 Hour
Standard Wall, Perpendicular To Fluted Deck Assembly rating 2 Hours
FLUTED METAL DECKWITH CONCRETE FILL
MINERAL WOOLRECTORSEALFLAMESAFE/BIOSTOPSPRAY (1/2" OVERLAPMETAL) ON ONE SIDEONLY
TYPICAL STEELFASTENERS BY DESIGN
CEMCOFAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
*Single Layer of 5/8” type “X” Gypsum Panel For 1 Hour Fire Rating
FAS Track 1000 Fluted Deck Details For 1* and 2 Hour Fire Ratings Additional joint systems can be found @ www.cemcosteel.com
HW-D-0551 HW-D-0553
HW-D-0573 HW-D-0623 I-Beam Penetration at Shaft Wall
Standard Wall, @ Fluted Deck Beam Penetration Assembly Rating 2 Hours
Shaft Wall, @ Fluted Deck Beam Penetration Assembly Rating 2 Hours
HW-D-0524
Standard Chase Wall, Perpendicular To Fluted Deck Assembly Rating 2 Hours
Standard Wall, Centered Directly Under Beam Assembly Rating 2 Hours
FIRE PROOFING ORMINERAL WOOL
STEEL BEAM
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
1/2" x 20 GA. Z-BAR OR16 GA. CRC BY DESIGN.
3/4" JOINT PROTECTION
5/8" TYPE"X" DRYWALL
#8 x 1/2" FRAMINGSCREW
FLUTED METAL DECK WITHCONCRETE FILL
CEMCO FASTRACK 1000
METAL STUDBY DESIGN
TYPICAL STEEL FASTENERSBY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
#8 x 1/2" FRAMING
SCREWCEMCO FAS TRACK 1000(TAPE ON FINISH SIDE ONLY)
5/8" TYPE "X"DRYWALL
METAL STUDSPACING BY DESIGN
RECTORSEAL/FLAMESAFE/BIOSTOPSPRAY 1/2" OVERLAPMETAL ( ON ONE SIDEONLY)
MINERAL WOOLFLUTED METAL DECKWITH CONCRETE FILL
3/4" JOINTPROTECTION
DRYWALL SCREW1" LOWER THANTRACK LEG
MINERAL WOOL STUFFEDBETWEEN FRAMING ANDFIREPROOFING 50%COMPRESSED
(2) LAYERSDRYWALL
Z-CLIP
CEMCOFAS TRACK 1000
METAL STUD
DRYWALL CUTAROUND I-BEAM WITH2" GAP
38" NOMINAL GAP
(34" JOINT PROTECTION)
I-BEAM
BIOSTOP SPRAYOVER MINERAL WOOLAND 1/2 OVERLAPONTO DDA BEFOREDRYWALL ISINSTALLED (ONE SIDEOF WALL ONLY)
CEMCOFAS TRACK 1000
FAS STRAP
MINERAL WOOL STUFFEDBETWEEN FRAMING ANDFIREPROOFING 50%COMPRESSED
(2) LAYERSDRYWALL
Z-CLIP
CEMCOFAS J-TRACK
CH STUD
DRYWALL CUTAROUND I-BEAM WITH2" GAP
38" NOMINAL GAP
(34" JOINT PROTECTION)
I-BEAM
BIOSTOP SPRAYOVER MINERAL WOOLAND 1/2 OVERLAPONTO DDA BEFOREDRYWALL ISINSTALLED (ONE SIDEOF WALL ONLY)
CEMCOFAS J-TRACK
Standard Wall, Parallel & Directly Under Deck Flute Assembly Rating 2 Hours
FLUTED METAL DECK
FILLED WITH CONCRETE CEMCO FAS STRAP
MIN. #6 FRAMINGSCREW BY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
CEMCOFAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
1/2" to 1 1/4" intumescent strip
10 3/6"
*Single Layer of 5/8” type “X” Gypsum Panel For 1 Hour Fire Rating
The Innovators of Quality Framing and Lath Systems CEMCO FAS 093X Specification Sheet
CEMCO’s FAS-093X Fire Rated control joint is a composite control joint with intumescent tape factory applied to the back side of the
control joint. The FAS-093X has been tested according to UL-2079 “Test For Fire Resistance of Building Joint Systems” and is used to
relieve stresses of expansion and contraction of drywall interior partitions or ceilings running in a horizontal or vertical direction. The
opening is protected by an orange plastic tape to indicate the fire rating. This tape is removed after joint compound has been applied and
the finish is completed. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade
33 Type H for 33 Ksi yield strength steel 13 mil thickness.
CALIFORNIA EXPANDED METAL LATH PRODUCTS CO.
Corporate Headquarters:
263 North Covina LaneCity of Industry, CA 91744Phone: 800.775.2362Fax: 626.330.7598
1001-A Pittsburg Antioch HwyPittsburg, CA 94565Phone: 925.473.9340Fax: 925.473.9341
490 Osage StreetDenver, CO 80204Phone: 303.572.3626Fax: 303.572.3627
8600 Will Rogers BlvdFt. Worth, TX 76140Phone: 817.568.1525Fax: 817.568.2759
N0 Fire Sealant
No Drywall Rips
NO Mineral Wool
1 and 2 hour Fire Ratings
Single Step Application
US Patent 8,671,632
800.775.2362 WWW.CEMCOSTEEL.COM
Corporate Headquarters &Main Manufacturing Facility
Northern CaliforniaManufacturing Facility
263 North Covina LaneCity of Industry, CA 91744
Phone: 800.775.2362Fax: 626.330.7598
1001-A Pittsburg Antioch HwyPittsburg, CA 94565
Phone: 925.473.9340Fax: 925.473.9341
Denver ColoradoManufacturing Facility
490 Osage StreetDenver, CO 80204
Phone: 303.572.3626Fax: 303.572.3627
8600 Will Rogers BlvdFt. Worth, TX 76140
Phone: 817.568.1525Fax: 817.568.2759
Ft. Worth TexasManufacturing Facility
Effective September 1, 2014
EQ 4.1 LOW-EMITTING MATERIALS – ADHESIVES AND SEALANTS:FAS Track’s intumescent fire-resistive seal is a solid, factory-applied layer, so it is not required to comply with the Adhesives and Sealants VOC limits. Moreover, because BlazeSeal provides all the fire protection required for many partitions, no spray-applied smoke seals or elastomeric fire-resistive sealants are required, so their VOC contributions are eliminated.
IEQ 4.6 LOW-EMITTING MATERIALS – CEILING AND WALL SYSTEMS (LEED FOR SCHOOLS): This credit does not apply to FAS Track. Only the gypsum board and the wall coverings are required to be tested.
IEQ 9 ENHANCED ACOUSTICAL PERFORMANCE (LEED FOR SCHOOLS): FAS Track improves the Sound Transmission Class (STC) of partitions, and can even eliminate the need for acoustical sealant at the head of partitions. Its resilient BlazeSeal layer helps damp sound transmission of partitions around core learning spaces and can help achieve this credit.
For other LEED credit contributions, see HYPERLINK “http://www.cemcosteel.com” www.cemcosteel.com and click “LEED Certification”.
If you have any questions, concerns, or clarifications, please contact our Technical Services Department at (800) 416-2278 or HYPERLINK “http://www.cemcosteel.com” www.cemcosteel.com.
FAS Track™ represents an environmental advancement for interior partition construction. Its resilient intumescent layer of Blaze Seal makes it a one-piece solution to acoustical and fire resistive head assemblies. FAS Track’s partition head assembly eliminates most bridging, elastomeric sealants, mineral wool, and the need to cut drywall to fit the flutes of decking. FAS Track reduces scraps and waste and often does not require any sealant to be applied to the head of wall joint. Resources are saved, and indoor air quality is improved.
FAS Track contributes to a number of LEED credits in the 2009 New Construction, Core and Shell, Commercial Interiors, and Schools rating systems.
RESOURCE CONSERVATION: Because even very short pieces of FAS Track are used in construction, very little is wasted. Scraps as small as 16 inches are often retained. The metal portion of smaller scraps can be recycled, once the BlazeSeal is peeled off by hand. For projects with high targets for MR 2 Construction Waste Management, this method of recycling FAS Track scraps will contribute to this credit.
MR CREDIT 4 RECYCLED CONTENT: Like all of CEMCO’s framing products, FAS Track contributes 32.7% recycled content to this credit.
IEQ 3.2 INDOOR AIR QUALITY MANAGEMENT PLAN – BEFORE OCCUPANCY: If the Air Testing option is selected by the project team, FAS Track is a valuable player in achieving this credit. FAS Track eliminates the need for spray-applied smoke seal and elastomeric fire sealant. It also can take the place of acoustical sealant in some assemblies. With no solvents and very low VOC content, FAS Track significantly reduces indoor air pollution. The Air Testing option is difficult to achieve, and every bit of indoor pollution that FAS Track eliminates from the project increases the chances of success.
FAS TRACK’S ENVIRONMENTAL BENEFITS AND LEED CONTRIBUTIONS