TENDER FORMFor the purchase of
Scientific Equipments / Instruments
Department of Pharmaceutical Sciences,
Saurashtra UniversityRajkot-360005
Form No._________
To,Registrar,Saurashtra University,Rajkot-360005
Dear Sir
1. In response to the Tender Notice published in the daily newspaper ________________,
dated___________, I/We submit herewith the tender form for supply of Scientific
Equipments/ Instruments. I/We have download the tender application form and here with
I/We attach tender form fees Rs 500/- in form of DD no___________________ of
Bank_____________________________dated________________.
2. I/We have thoroughly examined and understood the terms and conditions of the tender
contained in form and I/We agree to abide by them in full.
3. I/We offer to undertake the supply of scientific equipments/ Instruments and quoted the
rates inclusive of all taxes, freight, etc. F.O.R. Department of Pharmaceutical sciences,
Saurashtra University, Rajkot-360 005, Gujarat, INDIA, as given in Form. It is agreed that no
additional charges other than those mentioned in word be payable to me/us.
4. I/We accept that the rates offered shall remain valid for a period of 120 days from the date
of execution of agreement. I/We further agree that if the date up to which the offer would
remain open be declared as holiday for office, then offer will remain open for acceptance till
next working day.
5. I/We shall be bound by communication of acceptance of the offer, dispatched within
prescribed time.
6. I/We accept that the right to accept or reject whole or part of the tender without assigning
any reason is reserved with the Registrar of the University. The decision of the Registrar will
be final and shall be binding on me/us.
7. As required by the terms and conditions of tender an amount of Rs. ____________ (3% of
quoted price for instrument/Equipment, not less than Rs. 5000/-), paid by me/us as Earnest
Money Deposit (E.M.D.) through Fixed Deposit (FD) (DD will not be accepted) of
Rs._______________bearing No.____________________ & Bank Name
_______________________________________ dated _____________ in the joint names of
Party/ Supplier and Registrar, Saurashtra University, Rajkot-360 005. I/We aware that the
submitted Earnest Money Deposit will not be returned till completion of warranty period of
minimum two years if instrument/ equipment selected for purchase.
8. I/We agree to undertake to supply the instrument/ equipment at Department of
Pharmaceutical sciences, Saurashtra University, Rajkot-360 005, Gujarat, INDIA as
mentioned in final supply order and as per the specifications of the final orders within
stipulated time specified in the order from the date of firm order.
9. As per the terms and conditions, I/We am/are submitting our offer in envelope, includes
rates quoted by me/us as per the terms & conditions.
11. I/We hereby declare that the entries made in this Tender Form, are binding for me/us. I/We
shall be bound by the Act to my/our authorized representative duly constituted Attorney
Shri.___________________________________________ whose signature is appended
hereto in the place specified for the purpose and of any other person who in future may be
appointed by me/us in his place to carry on the business of this concern/agency/firm. The
intimation of such change will be given to the Registrar, Saurashtra University, Rajkot-360
005.
12. I/We hereby take the responsibility of commissioning with free demo and training and
maitaining the equipments at their location at free of cost during the warranty period. I/We
hereby take the responsibility to provide after sales services as per the terms and conditions
mutually aggreable to both the parties till the instrument/equipment is in use.
The following documents duly filled in and signed are enclosed along with terms and
conditions are retained by me/us for my/our information and record.
Name , Signature and Seal of Attorney Name , Signature and Seal of Supplier
Place: ____________
Date: ____________
Capacity in which signing: ___________________________________________
Name and Address of the firm/supplier: _________________________________
Registration No. of Supplier: _________________________________________
List of Documents:
i.
ii.
iii.
iv.
v.
vi.
Earnest Money Deposit (E.M.D.) through Fixed Deposit (FD) of Rs._____________ (3% of
quoted price for instrument/Equipment, not ltss than Rs. 5000/-) bearing No. & Bank Name
_______________________________________ dated _______________
TERMS & CONDITIONS
1. Sealed Tenders are invited from Manufacturers/ Authorized Reseller/ Authorized Dealers of Manufactures/or Authorized Suppliers for supply of scientific equipments/ lab equipmentsas per the specifications mentioned in Tender form. Complete tender form duly filled along with all details with non‐refundable tender form fee DD of Rs. 500/- for each instrument in favour of ‘Registrar Saurashtra University, Rajkot’, and EMD (FD only) as per terms and condition. The sealed cover duly superscripted with the name of instrument must reach on/before 22/11/2011 through Reg. A.D./Speed Post only to Head, Dept. Pharma. Sci., Saurashtra University, Rajkot-360005
2. The intending supplier shall also have to mention the name of manufacturer/ make, model of the article and has to enclose the pamphlets/ pictures of the equipments offered, for which the rates are quoted. In the absence of the above details of items offered may not beconsidered. The preference will be given to the party decided by the university authority without mentioning any reason. The decision of the university authority will be considered as final.
3. University will accept the tender for items mentioned Tender form from only(a)Manufacturers, (b)Authorized Reseller or dealer of overseas manufactures, (c)Authorized Dealers of manufactures and (d) any other Authorized Agency which is having adequate experience in supply and maintenance of equipments. Such agencies must enclose adequate documents to prove their claims. University authority reserves the rights to accept or reject tenders of these agencies. The decision of the University authority regarding this will be final and shall be binding to the party.
4. All the tenders must be delivered in sealed covers super-scribing the equipments name andtender number.
5. The tenderer should provide the following documents with superscription
TENDER FOR SUPPLY OF SCIENTIFIC EQUIPMENTS/ LAB EQUIPMENTS":
a) Certificate of Authorized Manufacturers/ Authorized Reseller/ Dealer of overseascompanies/ Authorized Dealers of manufactures/ Authorized Service Centers.
b) Clients list of Company/ Dealer and total experience in this field.
c) Sale Tax Registration No.
d) Undertaking by tenderer
6. Tenderer should furnish complete details of the latest technology available with full
documentation & descriptive literature and point out any special features of their system. Please note that changing of model after opening of tender will be liable to rejection of the offer.
7. Tenderer shall furnish details of the Back-up engineering and system support that will bemade available to Saurashtra University by the Manufacturers/ Authorized Reseller/ Authorized Dealers of Manufactures/or Authorized Suppliers.
8. The Registrar, Saurashtra University, Rajkot-360 005 reserves the right to revise or alter thespecifications of the equipment before the acceptance of tender and may ask for anydocument related with purchase at any point of time before issue of order.
9. The equipment must be capable of withstanding power failures and equipment should notbe damaged due to trip outs. The normal voltage and frequency conditions available at thesite are as follows: Normal voltage 230 + 10, 3 Phase 4 wire system unless stated other wiseFrequency 50 ±5%.
10. Electrical/ Electronic circuits are to be invariably made available at the time of supply along with service manuals.
11. Spare parts: Tenderer should include in their tender, provisions for adequate consumabletools and sufficient stock of maintenance spares as are essential for proper operation andmaintenance of the equipment and full particulars of the spare parts should be providedseparately. Estimated requirements of spares consumption per annum should be indicated.The successful Tenderer shall warranty that spare parts for the system would be available for a minimum period of 10 years after acceptance of the system/equipment. And thereafter before going out the production of the spare parts they will give a notice prior to suchdiscontinuation.
12. The tenderer shall be responsible for installation of the equipment at destination site and for making it fully operational. The DQ, IQ, PQ, OQ will be provided, where mandatory the equipment must be complying with the CFR-21 (relevant parts) & other regulatory requirements. The tenderer must provide complete details regarding space and all infrastructure needed for installation of the equipment which Saurashtra University should arrange before its arrival.
13. The tenderer shall be fully responsible for the manufacturers warranty in respect of properdesign, quality and workmanship of the equipment, accessories etc. covered by the tenderfor a period of 24 months from the date of installation of the system or other conditionsdecided mutually.
14. Tenderer shall make provision for imparting training to our technical team, faculty onoperation and use of equipment, its accessories and software for the intended applicationsand trouble shooting repair and maintenance. Cost of such training (if any) and the detailsregarding the course covered and its duration should be specified. Specify component of free training, duration, location & number of years training available for academics.
15. The supplier should issue a certificate that the equipment is of latest technology and will be upgraded as and when required by Saurashtra University and the equipment will bepromptly and properly serviced by them whenever desired by Saurashtra University.
16. All our imports will be under OGL and are exempted from payment of custom duty. However, current rules will be applicable as the case maybe. Any duty or surcharge leviedmust be mentioned in offer.
17. The Prices quoted must be firm and on CIF, Saurashtra University, Rajkot preferably.Different components of the price for insurance, freight installation and commissioning atdestination site should be shown separately. Discount offered, if any, should be indicatedprominently.
18. Prices should be shown separately for each item foreign exchange component, rupeeelement, basic unit, its accessories, computer, software, no. of units of consumables given,critical spares, components, etc.
19. Prices: submit your latest price catalogue.
20. The offer should be valid for a period of minimum 120 days from the specified date of opening. Delivery schedule may be indicated clearly in the tender.
21. The tenderer shall have to deposit Earnest Money Deposit (E.M.D.) through Fixed Deposit (FD) of Rs._____________ (3% of quoted price for instrument/Equipment, not less than Rs. 5000/-) bearing No. & Bank Name _______________________________________ dated _________ in the joint names of Party/ Supplier and Registrar, Saurashtra University, Rajkot-360005.
22. Wherever specifications are not given, the tenderer will quote for optional own specification & configurations flexibility.
23. Tender received without EMD shall be summarily rejected.
24. EMD of unsuccessful tenderer shall be released at the earliest possible after the award ofcontract/order on submission of plain application with Money Receipt in original.
25. Printed terms and conditions or the tenders will not be considered as forming part of theirtenders. In case terms and conditions of the contract applicable to this tender are not acceptable to any tenderer, he should clearly specify deviation in his tender.
26. All the tender documents must be duly stamped & signed by the Principals. If the IndianAgent/ Representative submits tender, then he will have to produce a certificate of suchauthority for making quotation on manufacturer's behalf.
27. Indian representatives of foreign suppliers shall have to submit their authorization certificate from the principals.
28. If the ordered Equipments are not provided within stipulated time limits, deduction @ 1% of the total cost order value per week for extra time taken will be done from the bill. However,
Registrar, Saurashtra university, Rajkot-360 005 may condone/ relax this penalty and may grant extension up to the time limit as deem fit by him, provided the tenderer applies and satisfies about genuineness of the reasons for delay in supply of instruments/equipments.
29. On acceptance of the rates as per the approved tender and after completing officialnecessary formalities, the tenderer will be informed about the acceptance of his tender. The supply order will be placed by respective officers of Saurashtra University, Rajkot.
30. As soon as the tenderer delivers the tender in the office of the undersigned, it shall bebinding on him and he shall not be able to withdraw or amend the offer.
31. The Registrar, Saurashtra university, Rajkot-360 005 also reserves the right to obtain the instruments/equipments by negotiations from one or more of the tenderer, if in case the rates, quality, make, specifications or other terms and conditions etc. of tenderer are not found suitable, to Saurashtra University.
32. The undersigned also reserves the right to accept or reject the supplies in full or in part which do not strictly stick up to the specifications or to accept the material/articles supplied with slight variations in specifications or with a condition that the rates accepted shall be reduced at such rates as the competent authority of the University may deem fit, looking to the variations and that such rates shall be binding on the tenderer.
33. University reserves the right to accept or reject - higher version of equipment/ instrument etc. or any other items under the same terms and conditions and same price quoted bytenderer in tender form
34. Bidders are required to submit terms, conditions and charges (special discounted academicprice) quoted for Annual Maintenance Contract (with & without spares parts) for next fiveyears after guarantee/warranty period is over or on call basis. Extension of warranty period after 2 years will also equally taken in to a consideration as other instrumental criteria like specification, price, model Etc.
35. While preparing the tender the following may please be mentioned clearly. Tender No., Description of items, price (whether inclusive/exclusive of taxes and duties), etc.
36. All the tenders should be addressed to The Registrar, C/o Head, Department of Pharmaceutical Sciences, Saurashtra University, Rajkot-360 005 Gujarat, India.
37. Late, delayed, incomplete, conditional tenders and amendments & additions to tender afteropening will not be accepted.
38. The University may arrange for a Technical Discussion meeting of the bidders preferably with the experts and/or of Advisory Committee Members of Department of Pharmaceutical Sciences, Saurashtra University, Rajkot, Where specifications offered by suppliers will be analyzed and clarifications, if any, sought. The exact date and time will be communicated to the bidders well in advance by Saurashtra University.
39. Orders for equipment will be dispatched to the successful party in two copies and the party
has to return one copy duly stamped and signed as a token of the acceptance of the order. In case the order confirmation is not received within time period of three weeks, it shall bepresumed that the vendor has not accepted the order and will be liable to be cancelled.
40. The credit bill should be presented in triplicate in the name of respective authority as quoted in final supply order is made. For any delay in payment, interest or any other kind of compensation, etc. the University will not make extra payment.
41. This contract will be governed as per terms and conditions mentioned above. Delay in supply within the prescribed time limit or the extended time limit, making of supplies not up to thestandard specification and performance or non-observance or non-acceptance of theseterms and conditions by the tenderer, shall constitute breach of contract and the security deposit or any other deposit of the tenderer shall be forfeited by the University besidesother actions of reduction in bills of supplies and/or other legal actions and finally thedecision of the University shall be binding on the tenderer
Registrar,Saurashtra University,
Rajkot-360005
SPECIFICATION FOR EQUIPMENTS/INSTRUMENTS
Sr. No. Description of Material Quantity
1. Differential Scanning Calorimeter (DSC) OneThermal Analysis System Software and Interface,
True compliance to GLP / GMP Preparation & management of reports using OLE. Networking
capability Customized reporting function
Differential Scanning Calorimeter, Heat Flux type measurement, Temperature Range:
-1400C to 6000C with liquid N2 supply(Built-in Devar) , Measuring Range: + 40 mW, Heating /
Cooling Program Rate: 0 to 99.9 0C/min or 0C/Hr, Hold Time: 0 to 999 min/Hr, 1 min to 999
hours Setting at 1 min or 1 hour increment. When temperature is more than 1000oC, hold
time should be less than 5 min. Cooling Time: Approx. 6 mins from to 6000C to 400C, Noise
Level: 1W, Measurement Atmosphere: Oxidative or Inert Gas
Type K (chromel–alumel) for sample section temperature, Type K (chromel–alumel) for
furnace section temperature, Type E (chromel–constantan) for heat flow (differential
measurement)
Furnace material: Copper plating with silver, Gas Flow Connection: 3 Flow Lines (Purge, Dry
& Cleaning Gas)
Auto cleaning of furnace and sensor, highly sensitive DTA detector inside the furnace
Cooling time:
In-built fan: ~ ca.20 minutes (600 to 50C) Cooling rate of –10C/min can be controlled from
600 to 1000C, Liquid N2: ~ 4 minutes from 100 to 0oC, ~ 6 minutes from 600 to 40oC, ~
10 minutes from 25 to –100oC Cooling rate of –10oC/min can be controlled from 600 to -700C,
Maximum cooling rate at -100oC is -7oC/min
30 minutes from room temperature to –50oC Cooling rate at –30oC is -5oC/min
Controlled cooling at 10 deg.C/min to -80 deg.C Spontaneous cooling rate of about 230 deg
C/min can be achieved if starting temperature is about 450 deg C
Time to reach 150C and hold: less than 1 min.
Heat flow noise: 1 µWRMS (Polypropylene, isothermal at 100C, 3µW)
Sensitivity: 2 µW/mm3
Minimum detectable peak: 2 µW, digital resolution: 0.001µW, Reproducibility: 0.1 %
Accuracy 0.5 % Temperature Accuracy + 0.50oC (Indium melting point)
Temperature Precision ± 0.15oC (Indium melting point)
Temperature Reproducibility ± 0.2oC (Indium melting point)
Temperature Resolution ± 0.01oC
Calorimetric Accuracy ± 1% (Indium endothermic peak)
Calorimetric Precision ± 1.3% (Indium)
Calorimetric Precision ± 0.5% (Indium endothermic peak)
Calorimetric Reproducibility ± 0.5% (Indium endothermic peak)
Calorimetric Resolution 1 µW Safety Check if sample pan is suitable for analysis temperature
range
Gas Inlet One each for:
Purging – inert gases supplied at 30 to 50 ml/min. Auto-switching of gases
Cleaning - air at 200 to 500 ml/min shold be supplied to bake and clean the furnace and
detector. On/off control with solenoid valve.
Drying – N gas at 200 to 500 ml/min can be supplied in order to prevent dew/ frost formation
when liquid N2 is used. Dimension 300 mm x 490 mm x 290 mm (W x D x H) Weight ~ 24 kg
Atmosphere Air or inert gas (normally N2) Static or flow (30 to 50 ml/min) Environment
Pressure:Atmospheric pressure, CE Marking Available
Sample Sealer & Crimper, Flow Controller, Aluminum Crimp Cells with Lids (500Pcs/Pkt)
Flow controller:
Primary Source-6 kg/cm2 maximum
Inlet 3 inlets-2 for purge gas, one for dry gas, Purge: 0 to 100 ml/min (calibrated for N2) Dry:
0-500 ml/min (calibrated for N2)
Measurement Of Flow Rate By pressure gauge (calibrated for N2)
Adjustment Of Flow Rate By pressure regulator
Operation Control: Manual or remote control via software
Gas On/Off By solenoid valve
Solenoid valve: brass for body, nitryl rubber for seal
Pipes Material: Connecting pipe for purge outlet: SUS 304
Resistance pipe for dry outlet: polyamide coated quartz capillary tube
suitable and accessories, software for the various type of analysis can be upgraded to Auto
sampler
Software requirements
Channel Controller: Simultaneously control and real time monitor 4 instruments at the same
time
Application: Full 32 bit multitasking operation of measurement and analysis
A/D Converter Resolution (Digital Resolution): 24 bit Transfer rate 10/s, i.e. the data is
acquired every 0.1 second
Digital Resolution: 16 million
Communication Interface: 1 serial port with RS-232 protocol
OS: WindowsTM95/98/2000/XP/vista
Calibration: Heat and temperature calibration by analysing compounds with known
transition temperature (e.g. melting) and heat. Some examples of more common compounds
are Indium, zinc, lead, etc. Up to 10 compounds can be used for calibration (10 point
calibration). The calibration factors are automatically calculated and stored in memory.
Parameter Setting:
99 heating stages
Auto-control of FC-60A, includes switching of gases
Sampling interval time: one data per 0.1 to 999 sec
Hold temperature – to reduce the lag temperature between furnace and
sample temperature
Sample set temperature – if sample is inserted when furnace is cold, frost can
forms on furnace. To prevents this, sample set temperature can be set at
ambient ensures. The furnace is heated rapidly to the set temperature before
the sample pan is inserted.
Types Of Manipulation:
Smoothing
Baseline correction
Heat correction
Temperature correction
Savitzky-Golay (first & second derivative)
Integral (area = heat)
Types Of Analysis:
Temperature, time, DSC signal
Melting point (tangent)
Peak height, temperature and heat, onset and endset temperature, peak area
Glass transition
Signal difference
Auto calculation
Data correction etc…
Functions:
Template files for analysis parameters and report
Auto-naming of files
Can simultaneously analyse 25 data at the same time
Auto-save analysis files in case of power failure
Snap shot function
Snap file – both analysis and post analysis can be carried out at the same time
ASCII conversion
OLE function where thermograms can be inserted into any WindowsTM
compatible software
Records data manipulation
Built-in email function
Cleaning furnace function
Optional Software Programs:
Purity
Specific heat capacity
Kinetics (Ozawa)
Partial area
ORThermal Analysis Software (Common for TGA & DSC) Consisting of Basic configuration of
the S/W: Mathematic Window, Install Plus Window, Purity Window, Multitasking, multicell &
multiuser Operation Using Windows XP/Vista Professional Operating System Integrated
Database INGRES, Database systems, each with possibilities Optimized for thermal analysis,
evaluations, Automatic calibration methods, result files etc. Export of files or database for
back-up on Hard disk or into external network INSTALL Software for system configuration
Containing basic TA Evaluations: Interactive or present automatic use of all Evaluation
functions which can be applied to DSC, TGA, TMA Export of files or database for backup on
hard disk and or into the external network. EVALUATIONS: Interactive or preset automatic
use of all evaluation functions which can be applied to several curves ONSET, ENDSET,
INTEGRATION, PEAK TEMPERATURE, STEP CALC. With horizontal or tangential
regression files, tables SDTA
Maximum measurement performance Through extensive calibration possibilities (Gas,
Taulag, heating rate, crucible) ONSET, ENDSET, Combined ONSET/ENDSET
INTEGRATION, PEAK TEMPERATURE, STEP CALC. With horizontal or tangential
regression lines, Tables, SDTA, normalization, signal deconvolution, X-Scaling with respect to
time, Temperature, sample Temperature, Option result setting using single step, Multistep or
multi-limit, auto limit, choice of different Baselines for DSC Evaluations (line, tangential,
Integral).IQ/OQ Books have to be provided
Software- Easy to use method and experiment editor for Programming of methods upto 10
segments, Introducing samples & loading of sample buffer Start / stop of experiments and
calibrations
DSC software-Evaluation of Glass Transition with/without Enthalpy relaxation Content,
Crystallinity Conversion & Enthalpy)
Temperature range: -140 to 700°C with liquid N2 supply, high-performance DSC measuring
unit, Furnace made of silver, with completely user replaceable Patented sensor with 56 point
AuAuPd thermopile and covered with ceramic protective layer, high resistance against
corrosion; Low-mass furnace permits to run MT Patented Multifrequency Temperature
Modulated DSC without hardware modifications; All types of calibration functions which
allows changes of crucibles, heating rates and gas types without additional calibration,
connectors for purge and reactive gas. Temp. accuracy: ± 0.2º C Temp Precision : ± 0.02º
C Measurement range: ± 350 mW ie 700mW
Resolution : 0.04 µW
Sensitivity : better than 0.1uW
Noise RMS: < 1µW RMS (a few mg indium) Digital Resolution: 16’000’000 Points Signal to
noise Ratio: 16:1 Signal time constant : <1.7s with light AI Crucibles Max. Sampling rate 50Hz
sampling interval 0.02sec. 3.6million data points Measuring cycle: upto 10 Data/sec With
standard accessories: such as Calibration Material (In and Zn), Standard Al.Crucibles with
Lids & cups, 40 µl,500 pcs
DSC Ceramic Sensor, Crucible Sealing Press
Thermostat, Purge Gas and Flow Meter for Operation
ORDSC Type Single furnace, Measurement principle Heat flux, Furnace material Alumina coated
aluminium, Temperature sensors-Thermocouple based. Precisely-machined disc of Chromel
alloy (90% Nickel / 10% Chromium) Modulated Temperature-DSC, Software Includes All
types of latest softwares related to DSC with Isothermal Kinetics, Scanning Kinetics, Specific
Heat and Purity software packages
Cooling accessories Cryofill (liquid N2), Chiller or circulator, Intracooler, Portable cooling
device,
Dual, digital mass flow-controller, Cooling accessory upgrades User exchangeable Includes
facility of Photocalorimetry
Calorimetric performance:
Dynamic range ±175 mW, Accuracy ±2%, Precision ±0.1%
Indium height/width (mW/°C)-8, Indium melting peak height/width at half- height. 1 mg
Indium, 10 °C/min, nitrogen purge. No mathematical treatment to the data or correction
applied.
Indium melting time-3.3 sec, Electronics Digital resolution-0.02 µW,
Temperature Range -180 °C to 450 °C, Accuracy ±0.1 °C, Precision ±0.02 °C, Data
points/sec 10, Controlled heating rates 0.1 to 100 °C/min, Cooling times – Intracooler (100
°C to 0 °C) Under 4 minutes
21 CFR Part 11 Compliance included, Qualification, verification and calibration services
included
Common for allthe parties:A good quality Electrical stabilizer, Crucible or cell sealing press and crimping device, System requires IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS, extra sample crucibles (500 in nos.)All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Thermal Analyzer
can also be considered
2. Spray Dryer One Suitable for: Aqueous / Aqueous + Solvents Feeds
Aceptic GMP unit
System Qualifications: CE Certification issued by international approval authority
(Quality control mark for the equipments)compulsory
Evaporation Rate: 1000ml of water evaporation/hr at max. drying air flow rate in
insulated condition
Drying Temp.: Ambient to 2800 C; Accuracy ± 1C
In steps of 0.1 C through Microcontroller preferable
Air Heater Capacity: 3.0 kw
Spray congealing
N2 inert loop
Aspirator – Blower Capacity: 85 Nm3 /hr; 0 to –250mm of water column vacuum with
variable frequency drive; in steps of 1% of capacity; controlled through VFD Controlled
Microcontroller
Aspirator Blower’s Motor: 0.25 HP x 2700 rpm 3 phase FLP – Motor with Single Phase
230V AC input & Three Phase 230V AC Output
Feed Pump Capacity: 1250ml/ hr with 3mm ID tube with variable speed control in steps
of 1% of pump capacity controlled through Microcontroller
Spray System: co-current as well as counter current spray – 0.7mm,and 0.5mm two
fluid spray nozzle madeup of SS 316
Auto jet Deblocking System for Spray Nozzle: Fitted on Co- current nozzle with variable
stroke interval through Microcontroller
Hot Air Flow: co-current as well as counter current
Main Body (Stand): SS 316 – with dull GMP pharmaceutical external finish by glass
bead shot blasting –Internally buffed to M-I dead mirror finish.
Air Heater Body: SS 316
Air Heater Element: Incolloy 800
Air Distributor: SS 316
Spray Nozzle with “o” rings: 0.5 mm (5 in no.) and 0.7 mm (5 in no.) and 1.0 (5 in no.)
All fluid spray nozzles of SS316
Drying Chamber: 6" Borosilicate glass; annealed- stress Relieved- spark tested two
piece construction for ease of cleaning
-Powder removal in Assembly
Cyclons: Borosilicate glass; annealed- stress relieved– spark tested, High Efficiency
Cyclon, Twin cyclone as well as high efficiency cyclone system
Threaded Couplers: Pure Teflon
Connecting Tubing: Alkathene Tubing
Cover of Product Receivers: Pure Teflon
Adjustable Support Stand for Receiver: Aluminum
Tube for Peristaltic Pump: Silicon Tubing
Scrubber Medii: 5 micron pp- washable
Scrubber bags (02 in nos.)
Teflon membrane scrubber
Teflon tube peristaltic pump
Teflon membrane absolute filter
All necessary software for spray dryer instrument and useful in research work
Teflon membrane with auto dedusting system
Ultrasonic spray nozzle
Fresh Air Filter: Prefilter – 5 microns, Hepa Filter – 0.3 microns
All Sealing gaskets & ‘O’ Rings: Teflon / Silicon
Extra set of all necessary glasswares must be provided
One extra set of Drying chamber(s) and cyclones of SS316 (Preferable)
Air Pressure Regulator Cum Filter for Spray Atomization: Janatics Make 0 - 10 kg/cm2
Built In Control System: Microcontroller based system with RS 485 port with LCD
display & annunciation Panel with audio visual indications with two way communication
between machine & computer configuration
The system must be provided with RS 485/232 port with two way communication with
users PC configuration with an option to operate the spray drier from MMI keypad or
from PC-Printer configuration
Built In Control System: Variable Frequency Drive for Aspirator Motor, The
microcontroller circuit will with 24V power supply for Input interrogation & for powering
DC Relays, ELCB protection is required provided, 2 Pole ELCB for Mains Incoming
220V- Single Phase Supply, 2 Pole MCB for Elect. Heater, Control Panel is provided
with 1 no. isolation relay, SSR is provided for 3.0 kw Elect. Heater, 2nos. Temperature
transmitters are provided for PT 100 resistance input & output 4 -20 MA for inlet/outlet
temp control, The system is provided with RS 485 for data logging of inlet/outlet temp;
hot air flow rate; feed pump flow rate
The software provided should be in compliance with US FDA 21 CFR Part 11
The equipment must be compliant with Health & safety Requirements of the EC
Directives as per EN 61010 - 1 : 2001 & EN 61326 - 1 : 1998 standards & should be CE
or UL ® Certified
The system must be provided with RS 485/232 port with two way communication with
users PC configuration with a option to operate the spray drier from MMI keypad or from
PC configuration
The MMI must have four line alphaneumeric display on online variable parameters / for
setting the variable parameters with display of online inlet / outlet temperature trends
The microprocessor should be upgradable for future additions of relevant accessories like
Inert Loop
Electrical stabilizer, System requires IBM compatible Personal desktop computer and
laser printer with all latest softwares installed,
All necessary accessories must be included with IQ/OQ/PQ documents
Extra Set(s) of “o” rings/Gasket
5 mm tip spray system
All the other necessary accessories must also be provided
Common forall parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPSAll necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents.
ORAny party with the specifications equivalent or higher than above mentioned for Spray Dryer can
also be considered
3. Spheronizer and Extruder OneSpheronizer
For conversion of needles into shperical spheres/pallets. It should be used in conjunction with
any design of extruder
Capacity – 25 to 50 gms
Contact parts – SS 316 L/316
Non contact parts – SS 304
Finishing – Dull Matt or sand (blasting) and internal mirror polish
Simens make 0.5 HP, 2 pole, 3 phase motor
Mitsubish/similar make 0.5 HP VFD for variable speed
Control panel mounted machine fixed
On/Off push button for motor with MCB Emergency Stop RPM display
2 mm pitch chequed plate
3 mm, 4 mm, 5 mm and 6 mm pitch chequed plat
Single screw extruder
Minimum processing capacity-25 gm to continue
All contact parts should be made up of SS 316/316L
Non contact parts should be madeup of SS 304
Surface finishing – Dull matt finishing feom out side or sand blasting and internal mirror polish
Simens/ Bonfiglioli make 0.75 HP, 1400 RPM, 3 phase motor
Bonfiglioli make worm reduction gear box
Control panel should be mounted on machine fixed
On/Off puch button with emergency switch MCB
Perforated plate – 1 mm (2 sets), 0.5 mm (2 sets), 0.8 mm (2 sets), 1.2 mm (2 sets), 1.5 mm
(2 sets), 2 mm (2 sets), 3 mm (2 sets), VFD attachment
All other necessary accessories and Tool Kit should be provided.
ORSpheronizer
All Spheronizer bowls made up of SS 316 (Preferable) of 250mm, 120mm, 85mm and 60mm
all interchangeable on the same base
Compatible with axial or screw type of extruders
Batch sizes from 1g to 150gm can be spheronized
Automatic recording of operational data and product temperature
Permanent records of every run can be made
PTFE/FEP coating on discs, Non-stick coating on drum(s)
Automatic run timer
Cabinet - 304 stainless steel
Non-stick coating of discs and bowls
Addition of Fines air required
Safety cover
All Spheronizer cross hatch discs of all the types and sizes with all different cut patterns
Heating/cooling water jacket on the spheronizer drum
Full IQ/OQ pharmaceutical regulatory packages and certified copies of mill materials
Oprational data collection package
Training at college site after delivery
Fully safety interlocked
Infinitely variable speed between approximately 600 to 3000 rpm
Integrated speed display
Storage facility of parameters directly and automatically on Computer
All types of kits/tools
Insert sleeve for insert kit
180W AC motor (or higher is preferred)
and
Extruder
Screen type extruser for dry and wet mass
0.8 to 3 mm (preferable) screen hole size
Automatic data recording
Different screen heights and roler sets
Different screen holes diameters (0.5mm to 2.5 mm)
Convenient batch size
Automatic data collection
Full pharmaceutical documentation
Fully safety interlocked
or
Extruder
Screw type
All different die(s) type must be provided.
Batch size starting from about 5g
All Interchangeable dies from 0.7mm to 2.0mm diameter with 0.1mm increments
Datastor facility
Motor 250 W AC
Contact parts: 316SS, Non contact parts 304SS
Standard extrusion dies with 1mm holes which can be substituted for other hole diameters
and designs also
Visual check of operation during extrusion
Manually loaded directly into the extrusion chamber
Extrusion by rotating screw thread in a fluted barrel with falling into the collecting tray
A direct reading tachometer for recording of extruder rotation speed, product temperature,
power consumption
Clear cover with safety interlock
Heating/cooling water jacket on the extruder barrel
or
Extruder
Variable die hole diameter and depth with both radial and axial extrusion
Should control density of the extrudate produced
Radial and axial extrusion in a single bench-top unit
Hole diameters ranging from 0.2 to 2.0mm must be provided (Preferable)
Hole depths ranging from 0.5mm to 8mm must be provided (Preferable)
All product contact components should be made up of 316 stainless steel,
and FDA approved polymers.
Fully safety interlocked.
Operating parameters should be manual and directly controlled by the user
Jacketed Screw Casing must be provided to heat or cool the product
Common for all the parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPSAll necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents.
OR
Any party with the specifications equivalent or higher than above mentioned for Spheronizer and Extruder can also be considered
4. Polarizing Microscope with Heating stage OneMain Body - Optical System: CFI60 infinity
Main Body -Illumination: 6V-30W halogen lamp; 6V-30W DC transformer built-in;
Diascopic/Episcopic illumination changeover switch; Fly-eye lens; NCB11, ND8 filters built-in;
Eyepiece: 10x (F.O.V. 22mm), CM type with crosshair and micrometer scale.
Eyepiece Tube: P-TT Trinocular Tube for polarizing microscopy; P-TB Binocular Tube for
polarizing microscopy
Intermediate Tube: Built-in focusable Bertrand lens removable from optical path; Switchable
Conoscopic/Orthoscopic observations; Analyzer built-in; Plate/compensator slot
Analyzer: 360° rotary dial; Minimum reading angle 0.1°
Nosepiece: Reversed centering quintuple nosepiece (detachable); DIN slot.
Stage: Top-grade dedicated circular graduated stage. Rotatable 360° horizontally; can be
fixed at a specific position. Graduated 360° (in 1° increments); Click stops each 45°.
Attachable mechanical stage: 35 x 25mm travel; vernier 0.1mm
Condenser: Dedicated strain-free swing-out type; P Achromat N.A. 0.9
Polarizer: Fixed to the bottom of the condenser holder; Scale
Objectives: CFI LU Plan Fluor Epi P 5X (N.A. 0.15/W.D. 23.5mm),
CFI LU Plan Fluor Epi P 10X (N.A. 0.3/W.D. 17.5mm),
CFI LU Plan Epi ELWD 20XA (NA/WD:0.40/13.00mm),
CFI LU Plan Epi ELWD 50XA (NA/WD:0.55/10.10mm)
Episcopic Illuminator: LV-UEPI Universal Epi-illuminator accommodates a 12V-50W
illumination transformer.
Compensators: Standard 1/4 λ & tint plate, quartz wedge.
Power Consumption: 1.2A/75W
IMAGE ANALYSIS SOFTWARE
Imaging Software for acquisition and device control upto three dimensional image
acquisition, Image Acquistion, Time Lapse Imaging, Z-Stack, Annotation, ND Viewer, Filter,
Large Image, Macro Report Generator facility, Vector layer & Multi-Dimensional File Format
(ND format)
Heating & Cooling Stage
Temperature Range -196°C to 420°C
Sample area of 53.5x43mm
32 Ramp temperature profile programming
15mm XY manipulation as standard
Sample holder for standard 76x26mm microscope slides
Gas tight chamber for atmospheric control
Swing out lid for easy sample loading
Can be used with transmitted or reflected light
Mounts directly to microscope table or substage
Stage body size: 160x80x24mm
100 Ohm platinum sensor
Temperature stability <0.1°C
Inner lid to increase temperature stability
Direct injection of coolant into block
Highly conductive metal for improved heat transfer
Minimum Heating Rate 0.01°C/min
Maximum heating rate of 50°C/min
Response time of <1 second at 5°C/min at 50°C
Objective lens minimum working distance: 6mm
Condenser lens minimum working distance: 13.2mm
Digital Camera: Fast 1394 CCD Colour - Bayer Mosaic, 12-bit, non-cooled
Cooling Systems: Automatic Control Cooling Systems (standard 39cm tubing incl. 2 litre
Dewar)For fast cooling to -196C
Liquid Crystal Pro System - This stage contains electrical spring clip terminals in the stage
chamber and a Liquid crystal cell holder with LC cells (5um gap ITO coated).
Comprising: Large Sample Area Stage with Electrical Connector, Standalone System
Controller, Liquid Crystal Cell Holder, Liquid Crystal Cells 5um gap, ITO Coated, Condenser
extension lens, Condenser extension lens, for Achromat swing out condenser MBL11300
Common for all the parties:Computer: Branded i3 Processorwith 2 GB RAM, 320GB HDD, Keyboard, Optical Mouse, Multimedia Kit, DVD Writer, 18.5" TFT Colour Monitor along with UPS, laser printer with all latest softwares installed, good quality electrical stabilizerAll necessary accessories must be included with IQ/OQ/PQ documents
Any party with the specifications equivalent or higher than above mentioned for Polarizing
Microscope with Heating stage can also be considered
5. Lyophilizer One Condenser capacity – minimum 4 liter
Condenser Material- It should be seamless stainless steel
Temperature- Enable processing of a full range of samples (-55, -75, -85 and - 105°C)
Auto Start-up, Pressure Controller, Compact Benchtop Footprint, Digital Display,
Microprocessor Control System, tube of vacuum grease required
Drain-Provision for easy drainage, Defrost-By hot gas, Drying chamber required
Safety-Power outage, condenser overload & Vacuum Safety alarms
SS manifold & Stainless steel adapter plate for high percentages of water as well as
organic solvents
CFC free refrigerant
Minimum 3 shelves (preferable) and internal condenser
Patented Quick seal valves
Minimum 600ml flask required with adapter
Vial capacity – 2 to 100 ml
Ampoule pack with ampoule adapter & sealing torch for Ampoules.
System should contains vacuum brake solenoid
Stoppering rack
Maximum deposition capacity – 0.13L/hour or more
No. of compressor – 1,2 or more (preferable)
Optional components required (Manifold, shelf rack)
System should be equipped with microprocessor based controller
Vacuum pump should be more than 100 LPM
System must achieve required vacuum in about 15 min
System Warranty remains for 1 years & 2 years of refrigeration warranty (preferable)
Pre Freezing Attachment, Voltage Stabilizer should be required
Expanded alarm capability, Product temperature and shelf temperature indication
Ability to condense up to 2 liters of ice in 24 hours
Vacuum Indication (Millitorr or Millibar selectable)- 760 Torr to 1 Millitorr, Vacuum
Regulation, Temperature–Vapor Pressure Conversion-Push Button type, System
Maintenance required
Optional top-down stoppering system, wizard work station required
Common for all the parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
OR
Any party with the specifications equivalent or higher than above mentioned for Lyophilizer/Freeze dryer can also be considered
6. High Speed Homogenizer One LCD display
Port for PC connection
LED speed indicator
Soft-starter
Digital speed controller, speed- 100 to 30,000 rpm
Stabilizer/ control knob
Different operation mode-standard, time, automatic and other mode also
Quiet drive system
Temperature controller
New quick coupling for low noise operation and for Dispersing aggregates, easy
cleaning dispersing aggregates
Volume capacity- 0.1 to 1000ml
Special shaft length possible inside
Tablet crushing tools
Drive unit, Stands and equipments (stand, vessel holder, safety positioning ring)
Dispersing vessels- 10 ml to 2000 ml
Interchangeable dispersing aggregates from 1 mm to 25 mm in diameter
CE label, compliant with RoHS, UL/CSA, CIP/SIP standards
Inline re-circulating dispersing system
Super fine generators for finer emulsions/ suspensions (nano in size)
Handle at end
Stroke withdrawing capacity
Having variety of application (batch size, mixing, dispensing)
Common for all the parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
OR
Any party with the specifications equivalent or higher than above mentioned for High Speed Homoginizer can also be considered
7. HPLC-MS OneHigh Sensitive LC-Ms system to quoted for pharmaceutical application like impurity profiling, forced degradation, stress studies, high potent drug quantitation, cleaning validation, dissolution profiling, peak tracking during method development
Solvent delivery Type: Quaternary Gradient analysis. Low pressure Proportionating, high
pressure was mixing HPLC.
Flow Rate of Pump: Up to 5 mL/min meeting all pharmaceutical applications and suitable for
Mass spectroscopy.
System Pressure requirement: At-least 5000 psi.
Solvent delivery hardware: Built in on line degassing chamber, vent valve in the pump for
priming, dry prime facility, only 2 inlet check valve for lesser maintenance, built in inline filter
for better and cleaner solvent delivery.
Sample management unit: Vials capacity ::> 110 vials in more than 4 different formats to
select any vial during ongoing run.
Must be temperature controlled for 4 to 40 Deg. C.
Injection mechanism: Must be flow through needle design and should have auto addition
and dilution facility.
Injector Features: Must be rotating vial carriage mechanism for changing of vial trays during
run is progressing.
Injector Loops: Injector Loops of different sizes to be quoted along with injector syringes.
Column Heater: System must have built in column heater assembly to connect MS suitable
columns like 1 mm ID, 2.1 mm ID and 4.6 mm ID columns. System must have built in pre
heater to avoid thermal gradient during analysis.
Optical Detector: Optical detector with 3D Scanning and 2D wavelength selection must be
quote. It must have flow cell with lower slit and bigger exit to minimize refractive index effect.
Detector must have faster data above 50 Hz.
Total system Volume: Must be <650 micro liter without hardware changes. Factory fit
specifications. System Band Spread should be <25uL for better MS Performance.
System Type: Single quadruple MS system.
Mass Range: From 2 – 3000 Da. With high resolution & Mass accuracy and Mass axis
stability of ±0.1 amu or better/24 hr; 3°c
Ionization Chamber: Dual orthogonal design with built in isolation valve for easy cleaning of
the system without venting the vacuum. It should have sampling cone and extraction cone for
better cleaning.
In source CID: Facility should be available to do in source fragmentation for better some
qualitative analysis.
Ion Source: Vendor must quote in standard quote both ESi and combined (Multimode)
source for both ESi and APCi facility for screening of new chemical entities. Software must
give complete information about PDA / UV, ESI +ve , ESI -ve , APCI, +ve and APCI –ve data
in single injection. It should also be able to have ELSD data if we procure in future in same
run.
ESI- pneumatically assisted electrospray to cover flow rates ≥ 1200 μl/min without split is
preferable.
System Speed: System must be capable of integrating HPLC / Fast LC / UPLC / UHPLC
analysis without splitting the flow. Polarity switching should be 20 ms, dwell time < 3 to 5 ms,
inter channel delay – 5 ms, inter scan delay – 5 ms. Scan Speed – 10000 amu/sec
System Sensitivity: 5 uL injection of 0.2 pg/uLfor more than 250 uL/min flow rate for
Reserpine should give Signal Noise ratio of 50:1 In ESi +ve mode with Root Mean square
(RMS) calculation. 5 uL injection of 0.2 pg/uL for more than 250 uL/min flow rate for
Reserpine should give Signal Noise ratio of 50:1 In ACPI +ve mode with Root Mean square
(RMS) calculation. System should have a dynamic rate of 10 e5
Detector: Detector should be 8kV conversion dynode dependent on Ion polarity and +9kV for
both modes with phosphor. It must be long life detector for lesser replacement on regular
interval. Vendor must guarantee the life of detector.
Vacuum System: Split Flow air cooled turbo molecular Pump with high efficiency and with
minimum maintenance and utility requirement.
System Fluidic Intelligence: Since this is academic institute and going to be used by
students, system must be extremely easy to use in terms of calibration using built in fluidics
with 2 different reservoirs. It should be able to check the health, run calibration, tuning for
scanning and SIR mode. It should also perform QC check for better confidence. Direct
infusion and mix with column flow facility should be available
Other Facility: Vendor must quote direct injection probe for liquid, semi solid and solid
samples, as we have synthetic lab to monitor reaction kinetics. It should also help us find out
counter fit drugs without any sample preparation.
Software: It should be provided with CPU of any make HP/Dell/ Lenovo with Windows XP SP
3 operating system having all required software and controls preferable to have required
preinstalled library. Software must be 21 CFR Part 11 compliance ready with software
validation should be given. Own software of 3rd party Software with relational data base has
to be quoted along which can control both LC and MS. System must have Chromatography
and MS Spectra to be compared in same software. Software must be pass word protected for
multilevel users. Software must have Secured audit trials for entire chromatography and MS.
It should have comprehensive data management tool in ORACLE database.
Utility Requirement: Required Gas supply like N2 Generator (With or without compressor)
must be quoted. If vendor is offering Generator without Compressor, they must quote in their
commercial bid. Required UPS with 1 hours battery backup has to be quoted. Please specify
and quote any other utility requirement.
Columns: 2.1 X 50 mm, 2.5 micron, C18, C8, Silica column with column tag facility to be
quoted. 4.6 X 150 mm, 3.5 micron C18 and Silica column to be quoted.
Operating modes: Manual and automated instrument optimization, automated instrument
calibration and resolution optimization (Auto tuning). Along with HPLC eluent connection into
MS; an external or built in syringe provision for direct infusion facility is require to operate MS
in standalone mode. Likewise facility for operating HPLC alone should be possible.
Proofs:
Vendor must give all pharmaceutical application proofs mentioned in the heading the
tender.
Vendor must give required specification sheets, proofs of specifications, videos, graphics
etc. in technical offer either hard copy or in CD.
Installation Base
Vendor must have installation of same system in Gujarat with reference name, address.
Email ID and telephone no. of customer for our confidence.
Warranty
System warranty must be mentioned
AMC cost
Required AMC cost must be mentioned in offer separately.
Spares and Consumables
Required consumables must be quoted along with system for both HPLC and MS system
for trouble free operation
Utility Requirement
As mentioned above
Training
Vendor must conduct in house training for students and faculties for LCMS operation and
as when required; they have to visit for further training.
Vendor shall also offer LCMS schools for certifying our trainers in our premises. Any other
training if required must be mentioned in the offer
Common for all the parties:Computer: Branded i3 Processorwith 2 GB RAM, 320GB HDD, Keyboard, Optical Mouse, Multimedia Kit, DVD Writer, 18.5" TFT Colour Monitor along with UPS, laser printer with all latest softwares installedAll necessary accessories must be included with IQ/OQ/PQ documents
OR
Any party with the specifications equivalent or higher than above mentioned for HPLC-MS can also be considered
8. Photo Stability Chamber Two Temperature Range: Upto 60 oC
Accuracy : +/- 0.1 oC
Lux Meter & Uv Meter
As per ICH Q1B-Option 2: TWO Different Florescent lamps for Visible and near UV
exposure which can be operated simultaneously or sequentially.
As per ICH Guidelines-1.2 Million Lux Hours of visible light and 200 watt hr/m2 of UV light.
Auto shut off after specified exposure level.
Side duck air circulation is provided to avoid interruption between both zones.
Individual timer is providing to ON/OFF UV and Florescent lights as required.
UV light get switched off automatically once you open the door
You can test samples on Fluorescent light or U.V. lights separately as well as combinely.
Controller System: PLC Based control System
Communication via Ethernet
Online monitoring on Graphical LCD Touch Screen Display
PLC Based Safety control to protect the chamber from overshoot of temp. and undershoot
of temp.
Auto changeover of Master sensor in case of failure
Changing Set value of Master controller from HMI with password protection with auto log
off
Password protected restores factory setting
Construction
Body & Door INSULATION: Poly urethane foam (PUF)
Chamber illumnination: Fluorescent tube & UV tube will be provided
Pore Holes: 60 mm Dia porthole is provided in the chamber for validation
HEATING SYSTEM - S.S. Nichrome Wire Embedded ‘U’ Shaped Air Heater.
REFRIGERATION SYSTEM - Cooling System Consists Of Condensor & Compressor.
COMPRESSOR - Hermetically Sealed Compressor
Tray
S.S. perforated type tray duly electro- polished
Capacity 200 to 400 ltrs
Safety Features
Temperature high cut off (°C.THC1) means the value you entered plus actual set point of
temperature, when the process value goes above the limit it cut off the STEAM GENERATOR
and DRY HEATER.
Temperature high cut off (°C.THC2) means the value you entered plus actual set point of
temperature, when the process value goes above the limit it cut off the MAIN CONTACTOR.
Temperature low cut off (°C.TLC1) means the value you entered plus actual set point of
temperature, when the process value goes below the limit it cut off the COMPRESSOR.
Temperature low cut off (°C.TLC2) means the value you entered plus actual set point of
temperature, when the process value goes below the limit it cut off the MAIN CONTACTOR.
SOFTWARE
21-CFR PART 11 COMPLIANCE SOFTWARE
Browser Based Software
Unlimited Equipment Connectivity
Secured audit trail (User, Equipment, Alarm SMS, Events).
Real time analysis
Online/Offline Graphical analysis for temp. and humidity
Open door with reason master
Automatically calculate MKT ( Mean Kinetic Temperature
OR
Material of Construction: Standard model or G.M.P. Model
Insulation: 3” Thick PUF Insulation.
Air Circulation: Blower to have uniformity of condition under chamber loaded condition.
Observation Door: Inside observation glass door with special neoprene gasket.
Handle / hinges: Imported French make handle and hinges for positive sealing with lock
and key arrangement.
Port Hole: 50 mm Port Hole with rubber seal to insert sensors for validation purpose.
Lighting: Interior illumination for working area.
Heating System: U shaped S.S. Nichrome wire air heaters.
Controller System: PLC Based control System
PHOTOSTABILITY EFFECT: Fluorescent Tubes for day light effect and UV tubes for ultra
violet ray in accordance to the ICH guidelines requirement of a lighting energy mounting to
1.2 W x 106 L x H (1.2 mil Lux hours) and an integrated UV energy share of 200 watts
hours/m2.
Refrigeration System: CFC Free Emerson (Kirloskar) Compressor with R 134 A (Eco
Friendly) refrigerant having state of art. By pass system for continues run of compressor
Stand by Refrigeration System: Ready for use refrigeration system in case the regular
system fails. Complete with Compressor, Condensor, Evaporator and Other Accessories with
Gas Charging.
Control System Imported Japanese Fuji make Microprocessor based PID controller with
digital display of temperature in deg. Centigrade and Humidity in Direct % RH.
Printer Interface: Facility to print records on printer with set values, actual values, date and
time with variable print time interval.
PC Interface: Facility to connect to a PC for data management with software. Compliance
to 21 CFR part 11.
Safety Features:
o Dedicated safety controller with separate sensor to cut off the supply in case of overshoot
and undershoot of Temperature giving audio visual alarm.
o Additional safety thermostat (Jumo German Make) to cut off the supply in case of
overshoot of temperature.
o 2 min. compressor ‘ON’ delay timer to safe guard the compressor.
Standard Model: Inside S. S. 304 mirror polished & Outside powder coated M.S.
G.M.P. Model: Inside S. S 316 mirror polish & Outside S. S 304 dull smooth buff.
Capacity: 400 Liters
Temperature Range 20 0 C to 600 C
Temperature Set Point 25 0 C
Temperature Accuracy ± 0.2 0 C
Temperature Uniformity ± 2 0 C
Complete with: Indication of light intensity in Lux. (Lux meter + UV Meter.)
Common for all the parties
A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
OR
Any party with the specifications equivalent or higher than above mentioned for Photo Stability Chamber can also be considered
9. Ultra Sonic Homogenizer One
Ultrasonic Power output: 750W
Ultrasonic Frequency: 20kHz
13 mm (1/2”) probe with threaded end and replaceable tip (Tips are autoclavable)
Extra probe for the volume ranging from 250µL to 1L
Automatic tuning, Energy (joules) Monitor, energy controller, digital wattmeter controller,
Temperature controller, Microprocessor based programmable LCD Screen with user
prompts alpha numeric display
Programmable process timer
Variable amplitude controller,
Full functional pulsar –ON and OFF cycle independently controllable from 1 to 59
seconds
Overload protection circuit
Remote actuation connector
Jack type sample holder.
Switch: for hands-free operation,10’ cable with plug.
Sound abating cabinet
Instruction manual
Tool kit
Common for All the PartiesA good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Ultra sonic
Homoginizer can also be considered
10. Inverted Microscope One Stand: Stand: Rugged and sturdy Inverted stand. It should have low positioned co-axial
coarse and fine focus knobs. It should have built-in electronic power supply for 12V / 30W
illuminator with conveniently positioned ON/OFF switch and regulating knob.
Optics: Microscope should have infinity colour corrected optics with high contrast and
resolution. The optical beam path should be ‘V’ shape with change over beam reflector for
observation and photography. The microscope should be suitable for bright field and phase
contrast techniques in transmitted light.
Nosepiece: Focusable Quadruple revolving objective nosepiece mounted on ball bearing
with highly precise click stops.
Stage: Mechanical stage with X-Y Movement, fixed stage plate with attachable
mechanical stage with inserts for various culture plates and flasks. Common mounting frame
to hold petri dishes of size 35-60mm and for slides. Mounting frame for microtest plates 60,72
and 120 positions for HLA with adhesive scales should be quoted. Auto ON/OFF switch on
stage for Halogen or LED Light for saving life of bulb. Automatically switched off after
15 minutes if unused.
Binocular Tube: Integrated binocular tube 45 with field of view 20mm on the microscope
stand with swiveling eyepiece tube.
Illumination: Built-in illumination to the stand with 12V / 30W tungsten halogen lamp. The
lamp should be easily changeable. Filter slider for day light and green filter. The power
supply for the lamp should be integrated in the stand and should be suitable for 220 - 240V
50Hz power supply. OR LED bulb of 3W white light.
Condenser: Long working Condenser 0.4 with built-in aperture diaphragm for bright field
and phase contrast. The condenser should be suitable for magnification range from 40x to
400x.
Objectives: Plan Achromatic long working distance objectives with high contrast and
resolution
4x/0.12 Ph
10x/0.25 Ph 1
20x/0.30 Ph 1
40x/0.50 Ph 1 or 2
Eyepieces: Wide field focusing eyepieces with minimum 20mm field of view with soft
rubber soft eyecups and is suitable for spectacle wearers. It should be marked with ± 5
diopter settings. The eyepieces should be suitable for graticule insertion.
Camera: 5 Megapixel CMOS Camera with pixel size of 2.2µm X 2.2µm. Integration with
computer through USB. Slot for SD Card, 4GB Storage card, with C-Mount Adapter.
Software: Image analysis software integrated with above camera. Software should
capable to operate above mentioned camera. Live imaging & measurement functions for
captured image. Basic application like colour adjustment, measurement (line, length, circle).
Scale on image.
Note: Fluorescence upgradable
or
Frame: Microscope stand with sextuple revolving nosepiece and two step light path
selector (observation: left side port= 100:0, 20:80), corresponded to near-infrared (700-
1000nm), relay lens, prism, dust proof glass-AW multi coated
Filters: Interference green contrast filters 45mm dia.
Nosepiece: Focusable Quadruple revolving objective nosepiece mounted on ball bearing
with highly precise click stops.
Stage: Stage extension plate. Plain stage. Attachable mechanical stage with flexible right-
hand vertical low drive controls, including scales for 96 micro test plates. Terasaki-plate
holder (72-well/60-well) for IX-MVR, including position scales. Slide glass holder for IX-MVR
Petri-dish holder (65mm dia. hole) for IX-MVR, including adapters with 54mm dia.hole
and35mm dia. hole
Binocular Tube: Binocular tube
Illumination: Illumination pillar for 30WHAL with one filter holder (45mm dia.), including
fixing screws AB5X35SA (4 pcs). Power supply for 30W halogen lamp with output cable
(0.64m) (Made in Philippines) Corresponded to WEEE regulation. 30W Halogen bulb (Philips
No. 5761) for BX40/41/45,IX50/51, CH40,CX31/40/41,CKX31/41, CK30/40,SZX2-
ILLK/ILLB/ILLD (Made in Germany) with power cord and Dust cover Type 020 for IX2,MVX10
( L 620mm x W 250mm x H 660 mm)
Condenser: Long working Condenser 0.4 with built-in aperture diaphragm for bright field
and phase contrast. The condenser should be suitable for magnification range from 40x to
400x.
Objectives: Acromat phase (pre-center) objective 10X/0.25, W.D. 8.8mm. Long working
distance achromat phase contrast (pre-center) objective 20X/0.4, WD 3.2. Long working
distance achromat phase contrast (pre-center) objective 40X/0.55, WD 2.2.
Eyepieces: Widefield eyepiece 10X, focusable with eyecups and suitable for spectacle
wearers.
Camera: 5 mega-pixel CMOS Color-Bayer Mosaic,10-bit, non-cooled, USB 2.0., with C
mount adapter
Software: Image analysis software integrated with above camera. Live imaging &
measurement functions for captured image. Basic application like colour adjustment,
measurement (line, length, circle). Scale on image.
Note: Fluorescence upgradable
or
Optical system: CFI60 infinity system, parfocal distance 60mm
Eyepiece tube: Siedentopf-type trinocular tube (light distribution, bino/photo: 100/0,
0/100)
Eyepiece tube: Interpupillary distance: 50–75 mm, Eyepoint height: 400mm from table,
Inclination: 45° from horizon
Nosepiece: Quintuple nosepiece, backward-facing type
Plain stage: Stage size: 170 x 225 mm, Stage height: 195mm from table, Acrylic window
provided, Auxiliary stage attachable
Illumination: Pre-centered 6V-30W halogen lamp, Filter frame (accepts 2 filters), Heat
absorbing filter and diffuser (Upgradable to 50W Epi fluorescence)
Attachable mechanical stage: Stage movement: 126 x 80 mm Accepts several micro-
test plate holders
Eyepiece lens: 10X
Condenser: ELWD condenser: N.A. 0.3 (O.D. 75mm) Non-centerable Phase Slider
Objectives:Apodized Phase Contrast Objective Lens, Achromat 4X, Achromat 10X,
Achromat 20X, andAchromat 40Xwith cover glass correction 0-2mm
Camera: 5 mega-pixel scientific CCD camera, USB 2.0., with C mount adapter
Note: Fluorescence upgradable
Common for All PartiesA good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
OR
Any party with the specifications equivalent or higher than above mentioned for Inverted Microscope can also be considered
11. Water Purification System OnePre-filtration System, with:
It should consist of 5 & 1 micron depth filter with retention efficiency greater than 80%,
enclosed in a polypropylene housing.
DC diaphragms pump to boost water pressure.
Pressure gauges to monitor the health of pre-filter cartridge.
Low pressure switch & high pressure switch to cut-off the system when this there is no
water in the inlet.
Unit should operate at < 50 decibel and should be wall mountable to save lab space.
Analytical Water Purification System with three stage purification,
First Stage: Should consist of a single pretreatment pack having 1 micron depth filter,
anti-scaling compound and silver impregnated activated carbon. The pack should also
have RFID tag for proper traceability.
Second Stage: Should consist of polyamide composite reverse osmosis membrane
with rejection efficiency of 94 – 99%.
Third Stage: Should consist of self-regenerating electrodeionisation module for removal
of ions and organics from RO water. The electrodeionisation module should have an
inbuilt mechanism of preventing scale formation at cathode.
System should have resistivity meter before and after RO module to measure the
percentage rejection. The percentage rejection monitored should be displayed on the
screen.
Built in coaxial type resistivity meter with a cell constant of 0.01 cm-1 and 0.10C
accuracy thermistor to measure resistivity of final purified water.
Should have a safety mechanism after RO to divert low quality permeate to drain and
thus protect downstream purification cartridges.
Should have pump with unique temperature feedback mechanism to ensure constant
flow rate irrespective of external temperature.
Should have an explicit 8 line alphanumeric display for viewing quality parameters and
any error / alarms.
System should be able to handle feed water with following parameters:
Conductivity: 1800 – 2000 µS/cm
Fouling Index (SDI): Upto 12
Total Chlorine: Upto 3 ppm
Product Water Quality:
Flow rate: 3 L/hr
TOC: < 30 ppb
Resisitivity: > 5 MΩ·cm
Conductivity: < 0.2 µS/cm
Silica Content: > 99.9 % retention
Reservoir: Cylindrical PE reservoir with 30 L or better capacity and sensor rod float
switch
Ultrapure Water Purification System, with: Should consist of single Purification pack
tailored to specific feed water source containing mixed bed ion exchange resin/ micro
filter / activated carbon. This should be followed by 0.22 um membrane filter in disc
stacking.
Should have easy plug and use design of purification cartridges
Built in coaxial type resistivity meter with a cell constant of 0.01 cm-1 and 0.10C
accuracy thermistor to measure resistivity of final purified water.
Automatic recirculation when system is not in use, to prevent contamination.
Should have a Preset of fixed volume dispense
Should have a point of use 0.22 micron filter in disc stacking having higher surface
area for filtration.
4 line alphanumeric colored control display showing product water resistivity
/conductivity, product water temperature, error & maintenance messages etc.
Product Water Quality
Flow rate: 1.0 ml/min.
TOC: <10 ppb
Resistivity/Conductivity: 18.2 MΩ·cm / 0.05 µS/cm
Particles: < 1 P/ml
Bacteria Level: < 0.1 cfu/ml
Common for All Parties
A good quality Electrical stabilizer, All necessary accessories apart from mentionedmust be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Inverted
Microscope can also be considered
12. Ultracentrifuge One RCF(x g): more than 1, 00, 000g
Speed control accuracy(rpm): ±50(5000 to max speed)
Max capacity: 1.5ml X 12 tubes
Timer: 1 min to 99 hrs and 59 min, with HOLD function, RTC Function
Vacuum system: oil rotary vacuum pump and oil diffusion pump. Pressure range
under 1.3 Pa
Rotor temp control range: -20-40˚C (1˚C increments)
Rotor cooling method: thermo module cooling system
Screen display: adjustable LCD display
Rotor setting method: quick setting
Operational noise: 46(db(A)*)
Drive unit warranty: 5 years
Common for All Parties
A good quality Electrical stabilizer, All necessary accessories apart from mentionedmust be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Inverted
Microscope can also be considered
13. Physiological data acquisition system for One recording ECG and NIBP
Software package including lession, ECG, NIBP, etc.
Data Acquisition Unit with USB Cable, DC Adapter and Cord
2 x Electrode Lead Sets
Disposable Electrodes (100/pk)
Abrasive Pads (10/pk)
Needle Electrode Bipolar
Needle electrode Unipolar 1.5 cm
Tail cliff apparatus for measuring noninvasive blood pressure:- Noninvasive BP-Sm.
Animal Tail 110/220 V, Tail Cuff/Sensor (specify 9.5/11/13 mm), Variable Range Force
Transducer
All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
OR
Any party with the specifications equivalent or higher than above mentioned for Physiologicaldata acquisition system for recording ECG and NIBP can also be considered
14. Sterotaxic Apparatus One Digital Lab Standard with LED Display
Speed Control Dial, Optional, 220 Volt
Motor Support w/Table Clamp
Drill Bit-1.35 mm
Mouse Adaptor
Rota Rod, mice and rats
Quattro 4 in 1 System, 220 Volt
Steel Brain Matrix, 1.0mm, Coronal, 40-75g
Steel Brain Matrix, 1.0mm, Coronal, 175-300gRodent Surgery Table
All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Sterotaxic
apparatus can also be considered
15. Digital Automatic Karl Fisher Titration apparatus One It should work For Solid, Liquid or Gas Sample
The Microprocessor based circuitry
The Key Board to feed data such as weight of sample in mgs, volume in ml and density
etc.
The Titer factor should be automatically calculated and presented on display
The End point detection by red lamp or alarm
The Moisture content should be calculated and displayed automatically in total moisture,
ppm or in percentage.
The instrument should provided with Connector for printer
All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Digital Automatic
Karl Fisher titration apparatus can also be considered
16. Polarimeter One Dual Scale
Temperature display
Optical density display
Temperature compensation: None, Sugar, Quartz
LED/ Interference filter
Printer and PC connection
Bright Display
Technical Specification:
Angular oA ISS oZ
Range -90 to +90 -225 to +225
Resolution 0.01 0.01
Accuracy ±0.02 ±0.05
Beam Diameter: 4.0 mm
Max. Tube length: 220 mm
Reading time: 15 Sec.
Temperature range: 5-40 oC
Common for All PartiesA good quality Electrical stabilizer, All necessary accessories apart from mentionedmust be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Polarimeter can
also be considered
17. Refractometer One Both refractive index and Brix scales with monitoring and displaying of prism temperature
on the integral display.
Water bath connection for temperature control with 4 decimal places
Brix Disperson measurement of solids material such as glass, contact lenses and fiber
optics.
It should be supplied with a glass calibration plate, contact liquid and instruction manual
and is packed in a hard flight case for easy transportation and storage. Range-1.30-1.70 RI, 0-95o
Resolution-0.0005, 0.25o Brix
Operating Temperature-5-70 oC Temperature Resolution-0.1o
Temperature Accuracy-±1oC
Storage/Ambient temperature - 5-40oC
Power Source - 1* AA alkaline 1.5 V dry cell
Approx. life 122 months continuous usage
Common for All PartiesA good quality Electrical stabilizer, All necessary accessories apart from mentioned
must be included with IQ/OQ/PQ documents
ORAny party with the specifications equivalent or higher than above mentioned for Refrectometer
can also be considered
UNDERTAKING
Undertaking to be given by the tenderer for supply of Scientific Equipments / Instrument Whereas,
The Registrar, Saurashtra University, Rajkot-360 005, has called for tenders for supplies as per the
tender form
I/We hereby offer our tender at the rates given in the tender form duly filled in and signed by me/us
and hereby also affix my/our signature(s) below this tender voluntary and full acceptance of all the
terms and conditions of this tender, which shall be the agreement between the above tender calling
authority and myself/us.
Signature of the Supplier: ______________________________________
Name of the Supplier: ______________________________________
Capacity in which signing: _____________________________________
Full address of the Supplier: ______________________________________
______________________________________
______________________________________
Place: With seal/stamp:Date: