final tender form 2011-12 auto saved)

35
TENDER FORM For the purchase of Scientific Equipments / Instruments Department of Pharmaceutical Sciences, Saurashtra University Rajkot-360005 Form No._________

Upload: devvaishnav

Post on 14-Sep-2014

57 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Final Tender Form 2011-12 Auto Saved)

TENDER FORMFor the purchase of

Scientific Equipments / Instruments

Department of Pharmaceutical Sciences,

Saurashtra UniversityRajkot-360005

Form No._________

Page 2: Final Tender Form 2011-12 Auto Saved)

To,Registrar,Saurashtra University,Rajkot-360005

Dear Sir

1. In response to the Tender Notice published in the daily newspaper ________________,

dated___________, I/We submit herewith the tender form for supply of Scientific

Equipments/ Instruments. I/We have download the tender application form and here with

I/We attach tender form fees Rs 500/- in form of DD no___________________ of

Bank_____________________________dated________________.

2. I/We have thoroughly examined and understood the terms and conditions of the tender

contained in form and I/We agree to abide by them in full.

3. I/We offer to undertake the supply of scientific equipments/ Instruments and quoted the

rates inclusive of all taxes, freight, etc. F.O.R. Department of Pharmaceutical sciences,

Saurashtra University, Rajkot-360 005, Gujarat, INDIA, as given in Form. It is agreed that no

additional charges other than those mentioned in word be payable to me/us.

4. I/We accept that the rates offered shall remain valid for a period of 120 days from the date

of execution of agreement. I/We further agree that if the date up to which the offer would

remain open be declared as holiday for office, then offer will remain open for acceptance till

next working day.

5. I/We shall be bound by communication of acceptance of the offer, dispatched within

prescribed time.

6. I/We accept that the right to accept or reject whole or part of the tender without assigning

any reason is reserved with the Registrar of the University. The decision of the Registrar will

be final and shall be binding on me/us.

7. As required by the terms and conditions of tender an amount of Rs. ____________ (3% of

quoted price for instrument/Equipment, not less than Rs. 5000/-), paid by me/us as Earnest

Money Deposit (E.M.D.) through Fixed Deposit (FD) (DD will not be accepted) of

Rs._______________bearing No.____________________ & Bank Name

Page 3: Final Tender Form 2011-12 Auto Saved)

_______________________________________ dated _____________ in the joint names of

Party/ Supplier and Registrar, Saurashtra University, Rajkot-360 005. I/We aware that the

submitted Earnest Money Deposit will not be returned till completion of warranty period of

minimum two years if instrument/ equipment selected for purchase.

8. I/We agree to undertake to supply the instrument/ equipment at Department of

Pharmaceutical sciences, Saurashtra University, Rajkot-360 005, Gujarat, INDIA as

mentioned in final supply order and as per the specifications of the final orders within

stipulated time specified in the order from the date of firm order.

9. As per the terms and conditions, I/We am/are submitting our offer in envelope, includes

rates quoted by me/us as per the terms & conditions.

11. I/We hereby declare that the entries made in this Tender Form, are binding for me/us. I/We

shall be bound by the Act to my/our authorized representative duly constituted Attorney

Shri.___________________________________________ whose signature is appended

hereto in the place specified for the purpose and of any other person who in future may be

appointed by me/us in his place to carry on the business of this concern/agency/firm. The

intimation of such change will be given to the Registrar, Saurashtra University, Rajkot-360

005.

12. I/We hereby take the responsibility of commissioning with free demo and training and

maitaining the equipments at their location at free of cost during the warranty period. I/We

hereby take the responsibility to provide after sales services as per the terms and conditions

mutually aggreable to both the parties till the instrument/equipment is in use.

The following documents duly filled in and signed are enclosed along with terms and

conditions are retained by me/us for my/our information and record.

Name , Signature and Seal of Attorney Name , Signature and Seal of Supplier

Place: ____________

Date: ____________

Page 4: Final Tender Form 2011-12 Auto Saved)

Capacity in which signing: ___________________________________________

Name and Address of the firm/supplier: _________________________________

Registration No. of Supplier: _________________________________________

List of Documents:

i.

ii.

iii.

iv.

v.

vi.

Earnest Money Deposit (E.M.D.) through Fixed Deposit (FD) of Rs._____________ (3% of

quoted price for instrument/Equipment, not ltss than Rs. 5000/-) bearing No. & Bank Name

_______________________________________ dated _______________

Page 5: Final Tender Form 2011-12 Auto Saved)

TERMS & CONDITIONS

1. Sealed Tenders are invited from Manufacturers/ Authorized Reseller/ Authorized Dealers of Manufactures/or Authorized Suppliers for supply of scientific equipments/ lab equipmentsas per the specifications mentioned in Tender form. Complete tender form duly filled along with all details with non‐refundable tender form fee DD of Rs. 500/- for each instrument in favour of ‘Registrar Saurashtra University, Rajkot’, and EMD (FD only) as per terms and condition. The sealed cover duly superscripted with the name of instrument must reach on/before 22/11/2011 through Reg. A.D./Speed Post only to Head, Dept. Pharma. Sci., Saurashtra University, Rajkot-360005

2. The intending supplier shall also have to mention the name of manufacturer/ make, model of the article and has to enclose the pamphlets/ pictures of the equipments offered, for which the rates are quoted. In the absence of the above details of items offered may not beconsidered. The preference will be given to the party decided by the university authority without mentioning any reason. The decision of the university authority will be considered as final.

3. University will accept the tender for items mentioned Tender form from only(a)Manufacturers, (b)Authorized Reseller or dealer of overseas manufactures, (c)Authorized Dealers of manufactures and (d) any other Authorized Agency which is having adequate experience in supply and maintenance of equipments. Such agencies must enclose adequate documents to prove their claims. University authority reserves the rights to accept or reject tenders of these agencies. The decision of the University authority regarding this will be final and shall be binding to the party.

4. All the tenders must be delivered in sealed covers super-scribing the equipments name andtender number.

5. The tenderer should provide the following documents with superscription

TENDER FOR SUPPLY OF SCIENTIFIC EQUIPMENTS/ LAB EQUIPMENTS":

a) Certificate of Authorized Manufacturers/ Authorized Reseller/ Dealer of overseascompanies/ Authorized Dealers of manufactures/ Authorized Service Centers.

b) Clients list of Company/ Dealer and total experience in this field.

c) Sale Tax Registration No.

d) Undertaking by tenderer

6. Tenderer should furnish complete details of the latest technology available with full

Page 6: Final Tender Form 2011-12 Auto Saved)

documentation & descriptive literature and point out any special features of their system. Please note that changing of model after opening of tender will be liable to rejection of the offer.

7. Tenderer shall furnish details of the Back-up engineering and system support that will bemade available to Saurashtra University by the Manufacturers/ Authorized Reseller/ Authorized Dealers of Manufactures/or Authorized Suppliers.

8. The Registrar, Saurashtra University, Rajkot-360 005 reserves the right to revise or alter thespecifications of the equipment before the acceptance of tender and may ask for anydocument related with purchase at any point of time before issue of order.

9. The equipment must be capable of withstanding power failures and equipment should notbe damaged due to trip outs. The normal voltage and frequency conditions available at thesite are as follows: Normal voltage 230 + 10, 3 Phase 4 wire system unless stated other wiseFrequency 50 ±5%.

10. Electrical/ Electronic circuits are to be invariably made available at the time of supply along with service manuals.

11. Spare parts: Tenderer should include in their tender, provisions for adequate consumabletools and sufficient stock of maintenance spares as are essential for proper operation andmaintenance of the equipment and full particulars of the spare parts should be providedseparately. Estimated requirements of spares consumption per annum should be indicated.The successful Tenderer shall warranty that spare parts for the system would be available for a minimum period of 10 years after acceptance of the system/equipment. And thereafter before going out the production of the spare parts they will give a notice prior to suchdiscontinuation.

12. The tenderer shall be responsible for installation of the equipment at destination site and for making it fully operational. The DQ, IQ, PQ, OQ will be provided, where mandatory the equipment must be complying with the CFR-21 (relevant parts) & other regulatory requirements. The tenderer must provide complete details regarding space and all infrastructure needed for installation of the equipment which Saurashtra University should arrange before its arrival.

13. The tenderer shall be fully responsible for the manufacturers warranty in respect of properdesign, quality and workmanship of the equipment, accessories etc. covered by the tenderfor a period of 24 months from the date of installation of the system or other conditionsdecided mutually.

14. Tenderer shall make provision for imparting training to our technical team, faculty onoperation and use of equipment, its accessories and software for the intended applicationsand trouble shooting repair and maintenance. Cost of such training (if any) and the detailsregarding the course covered and its duration should be specified. Specify component of free training, duration, location & number of years training available for academics.

Page 7: Final Tender Form 2011-12 Auto Saved)

15. The supplier should issue a certificate that the equipment is of latest technology and will be upgraded as and when required by Saurashtra University and the equipment will bepromptly and properly serviced by them whenever desired by Saurashtra University.

16. All our imports will be under OGL and are exempted from payment of custom duty. However, current rules will be applicable as the case maybe. Any duty or surcharge leviedmust be mentioned in offer.

17. The Prices quoted must be firm and on CIF, Saurashtra University, Rajkot preferably.Different components of the price for insurance, freight installation and commissioning atdestination site should be shown separately. Discount offered, if any, should be indicatedprominently.

18. Prices should be shown separately for each item foreign exchange component, rupeeelement, basic unit, its accessories, computer, software, no. of units of consumables given,critical spares, components, etc.

19. Prices: submit your latest price catalogue.

20. The offer should be valid for a period of minimum 120 days from the specified date of opening. Delivery schedule may be indicated clearly in the tender.

21. The tenderer shall have to deposit Earnest Money Deposit (E.M.D.) through Fixed Deposit (FD) of Rs._____________ (3% of quoted price for instrument/Equipment, not less than Rs. 5000/-) bearing No. & Bank Name _______________________________________ dated _________ in the joint names of Party/ Supplier and Registrar, Saurashtra University, Rajkot-360005.

22. Wherever specifications are not given, the tenderer will quote for optional own specification & configurations flexibility.

23. Tender received without EMD shall be summarily rejected.

24. EMD of unsuccessful tenderer shall be released at the earliest possible after the award ofcontract/order on submission of plain application with Money Receipt in original.

25. Printed terms and conditions or the tenders will not be considered as forming part of theirtenders. In case terms and conditions of the contract applicable to this tender are not acceptable to any tenderer, he should clearly specify deviation in his tender.

26. All the tender documents must be duly stamped & signed by the Principals. If the IndianAgent/ Representative submits tender, then he will have to produce a certificate of suchauthority for making quotation on manufacturer's behalf.

27. Indian representatives of foreign suppliers shall have to submit their authorization certificate from the principals.

28. If the ordered Equipments are not provided within stipulated time limits, deduction @ 1% of the total cost order value per week for extra time taken will be done from the bill. However,

Page 8: Final Tender Form 2011-12 Auto Saved)

Registrar, Saurashtra university, Rajkot-360 005 may condone/ relax this penalty and may grant extension up to the time limit as deem fit by him, provided the tenderer applies and satisfies about genuineness of the reasons for delay in supply of instruments/equipments.

29. On acceptance of the rates as per the approved tender and after completing officialnecessary formalities, the tenderer will be informed about the acceptance of his tender. The supply order will be placed by respective officers of Saurashtra University, Rajkot.

30. As soon as the tenderer delivers the tender in the office of the undersigned, it shall bebinding on him and he shall not be able to withdraw or amend the offer.

31. The Registrar, Saurashtra university, Rajkot-360 005 also reserves the right to obtain the instruments/equipments by negotiations from one or more of the tenderer, if in case the rates, quality, make, specifications or other terms and conditions etc. of tenderer are not found suitable, to Saurashtra University.

32. The undersigned also reserves the right to accept or reject the supplies in full or in part which do not strictly stick up to the specifications or to accept the material/articles supplied with slight variations in specifications or with a condition that the rates accepted shall be reduced at such rates as the competent authority of the University may deem fit, looking to the variations and that such rates shall be binding on the tenderer.

33. University reserves the right to accept or reject - higher version of equipment/ instrument etc. or any other items under the same terms and conditions and same price quoted bytenderer in tender form

34. Bidders are required to submit terms, conditions and charges (special discounted academicprice) quoted for Annual Maintenance Contract (with & without spares parts) for next fiveyears after guarantee/warranty period is over or on call basis. Extension of warranty period after 2 years will also equally taken in to a consideration as other instrumental criteria like specification, price, model Etc.

35. While preparing the tender the following may please be mentioned clearly. Tender No., Description of items, price (whether inclusive/exclusive of taxes and duties), etc.

36. All the tenders should be addressed to The Registrar, C/o Head, Department of Pharmaceutical Sciences, Saurashtra University, Rajkot-360 005 Gujarat, India.

37. Late, delayed, incomplete, conditional tenders and amendments & additions to tender afteropening will not be accepted.

38. The University may arrange for a Technical Discussion meeting of the bidders preferably with the experts and/or of Advisory Committee Members of Department of Pharmaceutical Sciences, Saurashtra University, Rajkot, Where specifications offered by suppliers will be analyzed and clarifications, if any, sought. The exact date and time will be communicated to the bidders well in advance by Saurashtra University.

39. Orders for equipment will be dispatched to the successful party in two copies and the party

Page 9: Final Tender Form 2011-12 Auto Saved)

has to return one copy duly stamped and signed as a token of the acceptance of the order. In case the order confirmation is not received within time period of three weeks, it shall bepresumed that the vendor has not accepted the order and will be liable to be cancelled.

40. The credit bill should be presented in triplicate in the name of respective authority as quoted in final supply order is made. For any delay in payment, interest or any other kind of compensation, etc. the University will not make extra payment.

41. This contract will be governed as per terms and conditions mentioned above. Delay in supply within the prescribed time limit or the extended time limit, making of supplies not up to thestandard specification and performance or non-observance or non-acceptance of theseterms and conditions by the tenderer, shall constitute breach of contract and the security deposit or any other deposit of the tenderer shall be forfeited by the University besidesother actions of reduction in bills of supplies and/or other legal actions and finally thedecision of the University shall be binding on the tenderer

Registrar,Saurashtra University,

Rajkot-360005

Page 10: Final Tender Form 2011-12 Auto Saved)

SPECIFICATION FOR EQUIPMENTS/INSTRUMENTS

Sr. No. Description of Material Quantity

1. Differential Scanning Calorimeter (DSC) OneThermal Analysis System Software and Interface,

True compliance to GLP / GMP Preparation & management of reports using OLE. Networking

capability Customized reporting function

Differential Scanning Calorimeter, Heat Flux type measurement, Temperature Range:

-1400C to 6000C with liquid N2 supply(Built-in Devar) , Measuring Range: + 40 mW, Heating /

Cooling Program Rate: 0 to 99.9 0C/min or 0C/Hr, Hold Time: 0 to 999 min/Hr, 1 min to 999

hours Setting at 1 min or 1 hour increment. When temperature is more than 1000oC, hold

time should be less than 5 min. Cooling Time: Approx. 6 mins from to 6000C to 400C, Noise

Level: 1W, Measurement Atmosphere: Oxidative or Inert Gas

Type K (chromel–alumel) for sample section temperature, Type K (chromel–alumel) for

furnace section temperature, Type E (chromel–constantan) for heat flow (differential

measurement)

Furnace material: Copper plating with silver, Gas Flow Connection: 3 Flow Lines (Purge, Dry

& Cleaning Gas)

Auto cleaning of furnace and sensor, highly sensitive DTA detector inside the furnace

Cooling time:

In-built fan: ~ ca.20 minutes (600 to 50C) Cooling rate of –10C/min can be controlled from

600 to 1000C, Liquid N2: ~ 4 minutes from 100 to 0oC, ~ 6 minutes from 600 to 40oC, ~

10 minutes from 25 to –100oC Cooling rate of –10oC/min can be controlled from 600 to -700C,

Maximum cooling rate at -100oC is -7oC/min

30 minutes from room temperature to –50oC Cooling rate at –30oC is -5oC/min

Controlled cooling at 10 deg.C/min to -80 deg.C Spontaneous cooling rate of about 230 deg

C/min can be achieved if starting temperature is about 450 deg C

Time to reach 150C and hold: less than 1 min.

Heat flow noise: 1 µWRMS (Polypropylene, isothermal at 100C, 3µW)

Sensitivity: 2 µW/mm3

Minimum detectable peak: 2 µW, digital resolution: 0.001µW, Reproducibility: 0.1 %

Accuracy 0.5 % Temperature Accuracy + 0.50oC (Indium melting point)

Temperature Precision ± 0.15oC (Indium melting point)

Temperature Reproducibility ± 0.2oC (Indium melting point)

Temperature Resolution ± 0.01oC

Calorimetric Accuracy ± 1% (Indium endothermic peak)

Calorimetric Precision ± 1.3% (Indium)

Calorimetric Precision ± 0.5% (Indium endothermic peak)

Calorimetric Reproducibility ± 0.5% (Indium endothermic peak)

Calorimetric Resolution 1 µW Safety Check if sample pan is suitable for analysis temperature

range

Page 11: Final Tender Form 2011-12 Auto Saved)

Gas Inlet One each for:

Purging – inert gases supplied at 30 to 50 ml/min. Auto-switching of gases

Cleaning - air at 200 to 500 ml/min shold be supplied to bake and clean the furnace and

detector. On/off control with solenoid valve.

Drying – N gas at 200 to 500 ml/min can be supplied in order to prevent dew/ frost formation

when liquid N2 is used. Dimension 300 mm x 490 mm x 290 mm (W x D x H) Weight ~ 24 kg

Atmosphere Air or inert gas (normally N2) Static or flow (30 to 50 ml/min) Environment

Pressure:Atmospheric pressure, CE Marking Available

Sample Sealer & Crimper, Flow Controller, Aluminum Crimp Cells with Lids (500Pcs/Pkt)

Flow controller:

Primary Source-6 kg/cm2 maximum

Inlet 3 inlets-2 for purge gas, one for dry gas, Purge: 0 to 100 ml/min (calibrated for N2) Dry:

0-500 ml/min (calibrated for N2)

Measurement Of Flow Rate By pressure gauge (calibrated for N2)

Adjustment Of Flow Rate By pressure regulator

Operation Control: Manual or remote control via software

Gas On/Off By solenoid valve

Solenoid valve: brass for body, nitryl rubber for seal

Pipes Material: Connecting pipe for purge outlet: SUS 304

Resistance pipe for dry outlet: polyamide coated quartz capillary tube

suitable and accessories, software for the various type of analysis can be upgraded to Auto

sampler

Software requirements

Channel Controller: Simultaneously control and real time monitor 4 instruments at the same

time

Application: Full 32 bit multitasking operation of measurement and analysis

A/D Converter Resolution (Digital Resolution): 24 bit Transfer rate 10/s, i.e. the data is

acquired every 0.1 second

Digital Resolution: 16 million

Communication Interface: 1 serial port with RS-232 protocol

OS: WindowsTM95/98/2000/XP/vista

Calibration: Heat and temperature calibration by analysing compounds with known

transition temperature (e.g. melting) and heat. Some examples of more common compounds

are Indium, zinc, lead, etc. Up to 10 compounds can be used for calibration (10 point

calibration). The calibration factors are automatically calculated and stored in memory.

Parameter Setting:

99 heating stages

Auto-control of FC-60A, includes switching of gases

Sampling interval time: one data per 0.1 to 999 sec

Hold temperature – to reduce the lag temperature between furnace and

sample temperature

Sample set temperature – if sample is inserted when furnace is cold, frost can

Page 12: Final Tender Form 2011-12 Auto Saved)

forms on furnace. To prevents this, sample set temperature can be set at

ambient ensures. The furnace is heated rapidly to the set temperature before

the sample pan is inserted.

Types Of Manipulation:

Smoothing

Baseline correction

Heat correction

Temperature correction

Savitzky-Golay (first & second derivative)

Integral (area = heat)

Types Of Analysis:

Temperature, time, DSC signal

Melting point (tangent)

Peak height, temperature and heat, onset and endset temperature, peak area

Glass transition

Signal difference

Auto calculation

Data correction etc…

Functions:

Template files for analysis parameters and report

Auto-naming of files

Can simultaneously analyse 25 data at the same time

Auto-save analysis files in case of power failure

Snap shot function

Snap file – both analysis and post analysis can be carried out at the same time

ASCII conversion

OLE function where thermograms can be inserted into any WindowsTM

compatible software

Records data manipulation

Built-in email function

Cleaning furnace function

Optional Software Programs:

Purity

Specific heat capacity

Kinetics (Ozawa)

Partial area

ORThermal Analysis Software (Common for TGA & DSC) Consisting of Basic configuration of

the S/W: Mathematic Window, Install Plus Window, Purity Window, Multitasking, multicell &

multiuser Operation Using Windows XP/Vista Professional Operating System Integrated

Database INGRES, Database systems, each with possibilities Optimized for thermal analysis,

evaluations, Automatic calibration methods, result files etc. Export of files or database for

Page 13: Final Tender Form 2011-12 Auto Saved)

back-up on Hard disk or into external network INSTALL Software for system configuration

Containing basic TA Evaluations: Interactive or present automatic use of all Evaluation

functions which can be applied to DSC, TGA, TMA Export of files or database for backup on

hard disk and or into the external network. EVALUATIONS: Interactive or preset automatic

use of all evaluation functions which can be applied to several curves ONSET, ENDSET,

INTEGRATION, PEAK TEMPERATURE, STEP CALC. With horizontal or tangential

regression files, tables SDTA

Maximum measurement performance Through extensive calibration possibilities (Gas,

Taulag, heating rate, crucible) ONSET, ENDSET, Combined ONSET/ENDSET

INTEGRATION, PEAK TEMPERATURE, STEP CALC. With horizontal or tangential

regression lines, Tables, SDTA, normalization, signal deconvolution, X-Scaling with respect to

time, Temperature, sample Temperature, Option result setting using single step, Multistep or

multi-limit, auto limit, choice of different Baselines for DSC Evaluations (line, tangential,

Integral).IQ/OQ Books have to be provided

Software- Easy to use method and experiment editor for Programming of methods upto 10

segments, Introducing samples & loading of sample buffer Start / stop of experiments and

calibrations

DSC software-Evaluation of Glass Transition with/without Enthalpy relaxation Content,

Crystallinity Conversion & Enthalpy)

Temperature range: -140 to 700°C with liquid N2 supply, high-performance DSC measuring

unit, Furnace made of silver, with completely user replaceable Patented sensor with 56 point

AuAuPd thermopile and covered with ceramic protective layer, high resistance against

corrosion; Low-mass furnace permits to run MT Patented Multifrequency Temperature

Modulated DSC without hardware modifications; All types of calibration functions which

allows changes of crucibles, heating rates and gas types without additional calibration,

connectors for purge and reactive gas. Temp. accuracy: ± 0.2º C Temp Precision : ± 0.02º

C Measurement range: ± 350 mW ie 700mW

Resolution : 0.04 µW

Sensitivity : better than 0.1uW

Noise RMS: < 1µW RMS (a few mg indium) Digital Resolution: 16’000’000 Points Signal to

noise Ratio: 16:1 Signal time constant : <1.7s with light AI Crucibles Max. Sampling rate 50Hz

sampling interval 0.02sec. 3.6million data points Measuring cycle: upto 10 Data/sec With

standard accessories: such as Calibration Material (In and Zn), Standard Al.Crucibles with

Lids & cups, 40 µl,500 pcs

DSC Ceramic Sensor, Crucible Sealing Press

Thermostat, Purge Gas and Flow Meter for Operation

ORDSC Type Single furnace, Measurement principle Heat flux, Furnace material Alumina coated

aluminium, Temperature sensors-Thermocouple based. Precisely-machined disc of Chromel

alloy (90% Nickel / 10% Chromium) Modulated Temperature-DSC, Software Includes All

types of latest softwares related to DSC with Isothermal Kinetics, Scanning Kinetics, Specific

Heat and Purity software packages

Cooling accessories Cryofill (liquid N2), Chiller or circulator, Intracooler, Portable cooling

device,

Page 14: Final Tender Form 2011-12 Auto Saved)

Dual, digital mass flow-controller, Cooling accessory upgrades User exchangeable Includes

facility of Photocalorimetry

Calorimetric performance:

Dynamic range ±175 mW, Accuracy ±2%, Precision ±0.1%

Indium height/width (mW/°C)-8, Indium melting peak height/width at half- height. 1 mg

Indium, 10 °C/min, nitrogen purge. No mathematical treatment to the data or correction

applied.

Indium melting time-3.3 sec, Electronics Digital resolution-0.02 µW,

Temperature Range -180 °C to 450 °C, Accuracy ±0.1 °C, Precision ±0.02 °C, Data

points/sec 10, Controlled heating rates 0.1 to 100 °C/min, Cooling times – Intracooler (100

°C to 0 °C) Under 4 minutes

21 CFR Part 11 Compliance included, Qualification, verification and calibration services

included

Common for allthe parties:A good quality Electrical stabilizer, Crucible or cell sealing press and crimping device, System requires IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS, extra sample crucibles (500 in nos.)All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Thermal Analyzer

can also be considered

2. Spray Dryer One Suitable for: Aqueous / Aqueous + Solvents Feeds

Aceptic GMP unit

System Qualifications: CE Certification issued by international approval authority

(Quality control mark for the equipments)compulsory

Evaporation Rate: 1000ml of water evaporation/hr at max. drying air flow rate in

insulated condition

Drying Temp.: Ambient to 2800 C; Accuracy ± 1C

In steps of 0.1 C through Microcontroller preferable

Air Heater Capacity: 3.0 kw

Spray congealing

N2 inert loop

Aspirator – Blower Capacity: 85 Nm3 /hr; 0 to –250mm of water column vacuum with

variable frequency drive; in steps of 1% of capacity; controlled through VFD Controlled

Microcontroller

Aspirator Blower’s Motor: 0.25 HP x 2700 rpm 3 phase FLP – Motor with Single Phase

230V AC input & Three Phase 230V AC Output

Feed Pump Capacity: 1250ml/ hr with 3mm ID tube with variable speed control in steps

of 1% of pump capacity controlled through Microcontroller

Spray System: co-current as well as counter current spray – 0.7mm,and 0.5mm two

fluid spray nozzle madeup of SS 316

Auto jet Deblocking System for Spray Nozzle: Fitted on Co- current nozzle with variable

stroke interval through Microcontroller

Page 15: Final Tender Form 2011-12 Auto Saved)

Hot Air Flow: co-current as well as counter current

Main Body (Stand): SS 316 – with dull GMP pharmaceutical external finish by glass

bead shot blasting –Internally buffed to M-I dead mirror finish.

Air Heater Body: SS 316

Air Heater Element: Incolloy 800

Air Distributor: SS 316

Spray Nozzle with “o” rings: 0.5 mm (5 in no.) and 0.7 mm (5 in no.) and 1.0 (5 in no.)

All fluid spray nozzles of SS316

Drying Chamber: 6" Borosilicate glass; annealed- stress Relieved- spark tested two

piece construction for ease of cleaning

-Powder removal in Assembly

Cyclons: Borosilicate glass; annealed- stress relieved– spark tested, High Efficiency

Cyclon, Twin cyclone as well as high efficiency cyclone system

Threaded Couplers: Pure Teflon

Connecting Tubing: Alkathene Tubing

Cover of Product Receivers: Pure Teflon

Adjustable Support Stand for Receiver: Aluminum

Tube for Peristaltic Pump: Silicon Tubing

Scrubber Medii: 5 micron pp- washable

Scrubber bags (02 in nos.)

Teflon membrane scrubber

Teflon tube peristaltic pump

Teflon membrane absolute filter

All necessary software for spray dryer instrument and useful in research work

Teflon membrane with auto dedusting system

Ultrasonic spray nozzle

Fresh Air Filter: Prefilter – 5 microns, Hepa Filter – 0.3 microns

All Sealing gaskets & ‘O’ Rings: Teflon / Silicon

Extra set of all necessary glasswares must be provided

One extra set of Drying chamber(s) and cyclones of SS316 (Preferable)

Air Pressure Regulator Cum Filter for Spray Atomization: Janatics Make 0 - 10 kg/cm2

Built In Control System: Microcontroller based system with RS 485 port with LCD

display & annunciation Panel with audio visual indications with two way communication

between machine & computer configuration

The system must be provided with RS 485/232 port with two way communication with

users PC configuration with an option to operate the spray drier from MMI keypad or

from PC-Printer configuration

Built In Control System: Variable Frequency Drive for Aspirator Motor, The

microcontroller circuit will with 24V power supply for Input interrogation & for powering

DC Relays, ELCB protection is required provided, 2 Pole ELCB for Mains Incoming

220V- Single Phase Supply, 2 Pole MCB for Elect. Heater, Control Panel is provided

with 1 no. isolation relay, SSR is provided for 3.0 kw Elect. Heater, 2nos. Temperature

Page 16: Final Tender Form 2011-12 Auto Saved)

transmitters are provided for PT 100 resistance input & output 4 -20 MA for inlet/outlet

temp control, The system is provided with RS 485 for data logging of inlet/outlet temp;

hot air flow rate; feed pump flow rate

The software provided should be in compliance with US FDA 21 CFR Part 11

The equipment must be compliant with Health & safety Requirements of the EC

Directives as per EN 61010 - 1 : 2001 & EN 61326 - 1 : 1998 standards & should be CE

or UL ® Certified

The system must be provided with RS 485/232 port with two way communication with

users PC configuration with a option to operate the spray drier from MMI keypad or from

PC configuration

The MMI must have four line alphaneumeric display on online variable parameters / for

setting the variable parameters with display of online inlet / outlet temperature trends

The microprocessor should be upgradable for future additions of relevant accessories like

Inert Loop

Electrical stabilizer, System requires IBM compatible Personal desktop computer and

laser printer with all latest softwares installed,

All necessary accessories must be included with IQ/OQ/PQ documents

Extra Set(s) of “o” rings/Gasket

5 mm tip spray system

All the other necessary accessories must also be provided

Common forall parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPSAll necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents.

ORAny party with the specifications equivalent or higher than above mentioned for Spray Dryer can

also be considered

3. Spheronizer and Extruder OneSpheronizer

For conversion of needles into shperical spheres/pallets. It should be used in conjunction with

any design of extruder

Capacity – 25 to 50 gms

Contact parts – SS 316 L/316

Non contact parts – SS 304

Finishing – Dull Matt or sand (blasting) and internal mirror polish

Simens make 0.5 HP, 2 pole, 3 phase motor

Mitsubish/similar make 0.5 HP VFD for variable speed

Control panel mounted machine fixed

On/Off push button for motor with MCB Emergency Stop RPM display

2 mm pitch chequed plate

3 mm, 4 mm, 5 mm and 6 mm pitch chequed plat

Single screw extruder

Minimum processing capacity-25 gm to continue

Page 17: Final Tender Form 2011-12 Auto Saved)

All contact parts should be made up of SS 316/316L

Non contact parts should be madeup of SS 304

Surface finishing – Dull matt finishing feom out side or sand blasting and internal mirror polish

Simens/ Bonfiglioli make 0.75 HP, 1400 RPM, 3 phase motor

Bonfiglioli make worm reduction gear box

Control panel should be mounted on machine fixed

On/Off puch button with emergency switch MCB

Perforated plate – 1 mm (2 sets), 0.5 mm (2 sets), 0.8 mm (2 sets), 1.2 mm (2 sets), 1.5 mm

(2 sets), 2 mm (2 sets), 3 mm (2 sets), VFD attachment

All other necessary accessories and Tool Kit should be provided.

ORSpheronizer

All Spheronizer bowls made up of SS 316 (Preferable) of 250mm, 120mm, 85mm and 60mm

all interchangeable on the same base

Compatible with axial or screw type of extruders

Batch sizes from 1g to 150gm can be spheronized

Automatic recording of operational data and product temperature

Permanent records of every run can be made

PTFE/FEP coating on discs, Non-stick coating on drum(s)

Automatic run timer

Cabinet - 304 stainless steel

Non-stick coating of discs and bowls

Addition of Fines air required

Safety cover

All Spheronizer cross hatch discs of all the types and sizes with all different cut patterns

Heating/cooling water jacket on the spheronizer drum

Full IQ/OQ pharmaceutical regulatory packages and certified copies of mill materials

Oprational data collection package

Training at college site after delivery

Fully safety interlocked

Infinitely variable speed between approximately 600 to 3000 rpm

Integrated speed display

Storage facility of parameters directly and automatically on Computer

All types of kits/tools

Insert sleeve for insert kit

180W AC motor (or higher is preferred)

and

Extruder

Screen type extruser for dry and wet mass

0.8 to 3 mm (preferable) screen hole size

Automatic data recording

Different screen heights and roler sets

Different screen holes diameters (0.5mm to 2.5 mm)

Page 18: Final Tender Form 2011-12 Auto Saved)

Convenient batch size

Automatic data collection

Full pharmaceutical documentation

Fully safety interlocked

or

Extruder

Screw type

All different die(s) type must be provided.

Batch size starting from about 5g

All Interchangeable dies from 0.7mm to 2.0mm diameter with 0.1mm increments

Datastor facility

Motor 250 W AC

Contact parts: 316SS, Non contact parts 304SS

Standard extrusion dies with 1mm holes which can be substituted for other hole diameters

and designs also

Visual check of operation during extrusion

Manually loaded directly into the extrusion chamber

Extrusion by rotating screw thread in a fluted barrel with falling into the collecting tray

A direct reading tachometer for recording of extruder rotation speed, product temperature,

power consumption

Clear cover with safety interlock

Heating/cooling water jacket on the extruder barrel

or

Extruder

Variable die hole diameter and depth with both radial and axial extrusion

Should control density of the extrudate produced

Radial and axial extrusion in a single bench-top unit

Hole diameters ranging from 0.2 to 2.0mm must be provided (Preferable)

Hole depths ranging from 0.5mm to 8mm must be provided (Preferable)

All product contact components should be made up of 316 stainless steel,

and FDA approved polymers.

Fully safety interlocked.

Operating parameters should be manual and directly controlled by the user

Jacketed Screw Casing must be provided to heat or cool the product

Common for all the parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPSAll necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents.

OR

Any party with the specifications equivalent or higher than above mentioned for Spheronizer and Extruder can also be considered

4. Polarizing Microscope with Heating stage OneMain Body - Optical System: CFI60 infinity

Page 19: Final Tender Form 2011-12 Auto Saved)

Main Body -Illumination: 6V-30W halogen lamp; 6V-30W DC transformer built-in;

Diascopic/Episcopic illumination changeover switch; Fly-eye lens; NCB11, ND8 filters built-in;

Eyepiece: 10x (F.O.V. 22mm), CM type with crosshair and micrometer scale.

Eyepiece Tube: P-TT Trinocular Tube for polarizing microscopy; P-TB Binocular Tube for

polarizing microscopy

Intermediate Tube: Built-in focusable Bertrand lens removable from optical path; Switchable

Conoscopic/Orthoscopic observations; Analyzer built-in; Plate/compensator slot

Analyzer: 360° rotary dial; Minimum reading angle 0.1°

Nosepiece: Reversed centering quintuple nosepiece (detachable); DIN slot.

Stage: Top-grade dedicated circular graduated stage. Rotatable 360° horizontally; can be

fixed at a specific position. Graduated 360° (in 1° increments); Click stops each 45°.

Attachable mechanical stage: 35 x 25mm travel; vernier 0.1mm

Condenser: Dedicated strain-free swing-out type; P Achromat N.A. 0.9

Polarizer: Fixed to the bottom of the condenser holder; Scale

Objectives: CFI LU Plan Fluor Epi P 5X (N.A. 0.15/W.D. 23.5mm),

CFI LU Plan Fluor Epi P 10X (N.A. 0.3/W.D. 17.5mm),

CFI LU Plan Epi ELWD 20XA (NA/WD:0.40/13.00mm),

CFI LU Plan Epi ELWD 50XA (NA/WD:0.55/10.10mm)

Episcopic Illuminator: LV-UEPI Universal Epi-illuminator accommodates a 12V-50W

illumination transformer.

Compensators: Standard 1/4 λ & tint plate, quartz wedge.

Power Consumption: 1.2A/75W

IMAGE ANALYSIS SOFTWARE

Imaging Software for acquisition and device control upto three dimensional image

acquisition, Image Acquistion, Time Lapse Imaging, Z-Stack, Annotation, ND Viewer, Filter,

Large Image, Macro Report Generator facility, Vector layer & Multi-Dimensional File Format

(ND format)

Heating & Cooling Stage

Temperature Range -196°C to 420°C

Sample area of 53.5x43mm

32 Ramp temperature profile programming

15mm XY manipulation as standard

Sample holder for standard 76x26mm microscope slides

Gas tight chamber for atmospheric control

Swing out lid for easy sample loading

Can be used with transmitted or reflected light

Mounts directly to microscope table or substage

Stage body size: 160x80x24mm

100 Ohm platinum sensor

Temperature stability <0.1°C

Inner lid to increase temperature stability

Direct injection of coolant into block

Highly conductive metal for improved heat transfer

Minimum Heating Rate 0.01°C/min

Page 20: Final Tender Form 2011-12 Auto Saved)

Maximum heating rate of 50°C/min

Response time of <1 second at 5°C/min at 50°C

Objective lens minimum working distance: 6mm

Condenser lens minimum working distance: 13.2mm

Digital Camera: Fast 1394 CCD Colour - Bayer Mosaic, 12-bit, non-cooled

Cooling Systems: Automatic Control Cooling Systems (standard 39cm tubing incl. 2 litre

Dewar)For fast cooling to -196C

Liquid Crystal Pro System - This stage contains electrical spring clip terminals in the stage

chamber and a Liquid crystal cell holder with LC cells (5um gap ITO coated).

Comprising: Large Sample Area Stage with Electrical Connector, Standalone System

Controller, Liquid Crystal Cell Holder, Liquid Crystal Cells 5um gap, ITO Coated, Condenser

extension lens, Condenser extension lens, for Achromat swing out condenser MBL11300

Common for all the parties:Computer: Branded i3 Processorwith 2 GB RAM, 320GB HDD, Keyboard, Optical Mouse, Multimedia Kit, DVD Writer, 18.5" TFT Colour Monitor along with UPS, laser printer with all latest softwares installed, good quality electrical stabilizerAll necessary accessories must be included with IQ/OQ/PQ documents

Any party with the specifications equivalent or higher than above mentioned for Polarizing

Microscope with Heating stage can also be considered

5. Lyophilizer One Condenser capacity – minimum 4 liter

Condenser Material- It should be seamless stainless steel

Temperature- Enable processing of a full range of samples (-55, -75, -85 and - 105°C)

Auto Start-up, Pressure Controller, Compact Benchtop Footprint, Digital Display,

Microprocessor Control System, tube of vacuum grease required

Drain-Provision for easy drainage, Defrost-By hot gas, Drying chamber required

Safety-Power outage, condenser overload & Vacuum Safety alarms

SS manifold & Stainless steel adapter plate for high percentages of water as well as

organic solvents

CFC free refrigerant

Minimum 3 shelves (preferable) and internal condenser

Patented Quick seal valves

Minimum 600ml flask required with adapter

Vial capacity – 2 to 100 ml

Ampoule pack with ampoule adapter & sealing torch for Ampoules.

System should contains vacuum brake solenoid

Stoppering rack

Maximum deposition capacity – 0.13L/hour or more

No. of compressor – 1,2 or more (preferable)

Optional components required (Manifold, shelf rack)

System should be equipped with microprocessor based controller

Vacuum pump should be more than 100 LPM

System must achieve required vacuum in about 15 min

Page 21: Final Tender Form 2011-12 Auto Saved)

System Warranty remains for 1 years & 2 years of refrigeration warranty (preferable)

Pre Freezing Attachment, Voltage Stabilizer should be required

Expanded alarm capability, Product temperature and shelf temperature indication

Ability to condense up to 2 liters of ice in 24 hours

Vacuum Indication (Millitorr or Millibar selectable)- 760 Torr to 1 Millitorr, Vacuum

Regulation, Temperature–Vapor Pressure Conversion-Push Button type, System

Maintenance required

Optional top-down stoppering system, wizard work station required

Common for all the parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

OR

Any party with the specifications equivalent or higher than above mentioned for Lyophilizer/Freeze dryer can also be considered

6. High Speed Homogenizer One LCD display

Port for PC connection

LED speed indicator

Soft-starter

Digital speed controller, speed- 100 to 30,000 rpm

Stabilizer/ control knob

Different operation mode-standard, time, automatic and other mode also

Quiet drive system

Temperature controller

New quick coupling for low noise operation and for Dispersing aggregates, easy

cleaning dispersing aggregates

Volume capacity- 0.1 to 1000ml

Special shaft length possible inside

Tablet crushing tools

Drive unit, Stands and equipments (stand, vessel holder, safety positioning ring)

Dispersing vessels- 10 ml to 2000 ml

Interchangeable dispersing aggregates from 1 mm to 25 mm in diameter

CE label, compliant with RoHS, UL/CSA, CIP/SIP standards

Inline re-circulating dispersing system

Super fine generators for finer emulsions/ suspensions (nano in size)

Handle at end

Stroke withdrawing capacity

Having variety of application (batch size, mixing, dispensing)

Common for all the parties:A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

Page 22: Final Tender Form 2011-12 Auto Saved)

OR

Any party with the specifications equivalent or higher than above mentioned for High Speed Homoginizer can also be considered

7. HPLC-MS OneHigh Sensitive LC-Ms system to quoted for pharmaceutical application like impurity profiling, forced degradation, stress studies, high potent drug quantitation, cleaning validation, dissolution profiling, peak tracking during method development

Solvent delivery Type: Quaternary Gradient analysis. Low pressure Proportionating, high

pressure was mixing HPLC.

Flow Rate of Pump: Up to 5 mL/min meeting all pharmaceutical applications and suitable for

Mass spectroscopy.

System Pressure requirement: At-least 5000 psi.

Solvent delivery hardware: Built in on line degassing chamber, vent valve in the pump for

priming, dry prime facility, only 2 inlet check valve for lesser maintenance, built in inline filter

for better and cleaner solvent delivery.

Sample management unit: Vials capacity ::> 110 vials in more than 4 different formats to

select any vial during ongoing run.

Must be temperature controlled for 4 to 40 Deg. C.

Injection mechanism: Must be flow through needle design and should have auto addition

and dilution facility.

Injector Features: Must be rotating vial carriage mechanism for changing of vial trays during

run is progressing.

Injector Loops: Injector Loops of different sizes to be quoted along with injector syringes.

Column Heater: System must have built in column heater assembly to connect MS suitable

columns like 1 mm ID, 2.1 mm ID and 4.6 mm ID columns. System must have built in pre

heater to avoid thermal gradient during analysis.

Optical Detector: Optical detector with 3D Scanning and 2D wavelength selection must be

quote. It must have flow cell with lower slit and bigger exit to minimize refractive index effect.

Detector must have faster data above 50 Hz.

Total system Volume: Must be <650 micro liter without hardware changes. Factory fit

specifications. System Band Spread should be <25uL for better MS Performance.

System Type: Single quadruple MS system.

Mass Range: From 2 – 3000 Da. With high resolution & Mass accuracy and Mass axis

stability of ±0.1 amu or better/24 hr; 3°c

Ionization Chamber: Dual orthogonal design with built in isolation valve for easy cleaning of

the system without venting the vacuum. It should have sampling cone and extraction cone for

better cleaning.

In source CID: Facility should be available to do in source fragmentation for better some

qualitative analysis.

Ion Source: Vendor must quote in standard quote both ESi and combined (Multimode)

source for both ESi and APCi facility for screening of new chemical entities. Software must

give complete information about PDA / UV, ESI +ve , ESI -ve , APCI, +ve and APCI –ve data

in single injection. It should also be able to have ELSD data if we procure in future in same

Page 23: Final Tender Form 2011-12 Auto Saved)

run.

ESI- pneumatically assisted electrospray to cover flow rates ≥ 1200 μl/min without split is

preferable.

System Speed: System must be capable of integrating HPLC / Fast LC / UPLC / UHPLC

analysis without splitting the flow. Polarity switching should be 20 ms, dwell time < 3 to 5 ms,

inter channel delay – 5 ms, inter scan delay – 5 ms. Scan Speed – 10000 amu/sec

System Sensitivity: 5 uL injection of 0.2 pg/uLfor more than 250 uL/min flow rate for

Reserpine should give Signal Noise ratio of 50:1 In ESi +ve mode with Root Mean square

(RMS) calculation. 5 uL injection of 0.2 pg/uL for more than 250 uL/min flow rate for

Reserpine should give Signal Noise ratio of 50:1 In ACPI +ve mode with Root Mean square

(RMS) calculation. System should have a dynamic rate of 10 e5

Detector: Detector should be 8kV conversion dynode dependent on Ion polarity and +9kV for

both modes with phosphor. It must be long life detector for lesser replacement on regular

interval. Vendor must guarantee the life of detector.

Vacuum System: Split Flow air cooled turbo molecular Pump with high efficiency and with

minimum maintenance and utility requirement.

System Fluidic Intelligence: Since this is academic institute and going to be used by

students, system must be extremely easy to use in terms of calibration using built in fluidics

with 2 different reservoirs. It should be able to check the health, run calibration, tuning for

scanning and SIR mode. It should also perform QC check for better confidence. Direct

infusion and mix with column flow facility should be available

Other Facility: Vendor must quote direct injection probe for liquid, semi solid and solid

samples, as we have synthetic lab to monitor reaction kinetics. It should also help us find out

counter fit drugs without any sample preparation.

Software: It should be provided with CPU of any make HP/Dell/ Lenovo with Windows XP SP

3 operating system having all required software and controls preferable to have required

preinstalled library. Software must be 21 CFR Part 11 compliance ready with software

validation should be given. Own software of 3rd party Software with relational data base has

to be quoted along which can control both LC and MS. System must have Chromatography

and MS Spectra to be compared in same software. Software must be pass word protected for

multilevel users. Software must have Secured audit trials for entire chromatography and MS.

It should have comprehensive data management tool in ORACLE database.

Utility Requirement: Required Gas supply like N2 Generator (With or without compressor)

must be quoted. If vendor is offering Generator without Compressor, they must quote in their

commercial bid. Required UPS with 1 hours battery backup has to be quoted. Please specify

and quote any other utility requirement.

Columns: 2.1 X 50 mm, 2.5 micron, C18, C8, Silica column with column tag facility to be

quoted. 4.6 X 150 mm, 3.5 micron C18 and Silica column to be quoted.

Operating modes: Manual and automated instrument optimization, automated instrument

calibration and resolution optimization (Auto tuning). Along with HPLC eluent connection into

MS; an external or built in syringe provision for direct infusion facility is require to operate MS

in standalone mode. Likewise facility for operating HPLC alone should be possible.

Proofs:

Page 24: Final Tender Form 2011-12 Auto Saved)

Vendor must give all pharmaceutical application proofs mentioned in the heading the

tender.

Vendor must give required specification sheets, proofs of specifications, videos, graphics

etc. in technical offer either hard copy or in CD.

Installation Base

Vendor must have installation of same system in Gujarat with reference name, address.

Email ID and telephone no. of customer for our confidence.

Warranty

System warranty must be mentioned

AMC cost

Required AMC cost must be mentioned in offer separately.

Spares and Consumables

Required consumables must be quoted along with system for both HPLC and MS system

for trouble free operation

Utility Requirement

As mentioned above

Training

Vendor must conduct in house training for students and faculties for LCMS operation and

as when required; they have to visit for further training.

Vendor shall also offer LCMS schools for certifying our trainers in our premises. Any other

training if required must be mentioned in the offer

Common for all the parties:Computer: Branded i3 Processorwith 2 GB RAM, 320GB HDD, Keyboard, Optical Mouse, Multimedia Kit, DVD Writer, 18.5" TFT Colour Monitor along with UPS, laser printer with all latest softwares installedAll necessary accessories must be included with IQ/OQ/PQ documents

OR

Any party with the specifications equivalent or higher than above mentioned for HPLC-MS can also be considered

8. Photo Stability Chamber Two Temperature Range: Upto 60 oC

Accuracy : +/- 0.1 oC

Lux Meter & Uv Meter

As per ICH Q1B-Option 2: TWO Different Florescent lamps for Visible and near UV

exposure which can be operated simultaneously or sequentially.

As per ICH Guidelines-1.2 Million Lux Hours of visible light and 200 watt hr/m2 of UV light.

Auto shut off after specified exposure level.

Side duck air circulation is provided to avoid interruption between both zones.

Individual timer is providing to ON/OFF UV and Florescent lights as required.

UV light get switched off automatically once you open the door

You can test samples on Fluorescent light or U.V. lights separately as well as combinely.

Controller System: PLC Based control System

Communication via Ethernet

Page 25: Final Tender Form 2011-12 Auto Saved)

Online monitoring on Graphical LCD Touch Screen Display

PLC Based Safety control to protect the chamber from overshoot of temp. and undershoot

of temp.

Auto changeover of Master sensor in case of failure

Changing Set value of Master controller from HMI with password protection with auto log

off

Password protected restores factory setting

Construction

Body & Door INSULATION: Poly urethane foam (PUF)

Chamber illumnination: Fluorescent tube & UV tube will be provided

Pore Holes: 60 mm Dia porthole is provided in the chamber for validation

HEATING SYSTEM - S.S. Nichrome Wire Embedded ‘U’ Shaped Air Heater.

REFRIGERATION SYSTEM - Cooling System Consists Of Condensor & Compressor.

COMPRESSOR - Hermetically Sealed Compressor

Tray

S.S. perforated type tray duly electro- polished

Capacity 200 to 400 ltrs

Safety Features

Temperature high cut off (°C.THC1) means the value you entered plus actual set point of

temperature, when the process value goes above the limit it cut off the STEAM GENERATOR

and DRY HEATER.

Temperature high cut off (°C.THC2) means the value you entered plus actual set point of

temperature, when the process value goes above the limit it cut off the MAIN CONTACTOR.

Temperature low cut off (°C.TLC1) means the value you entered plus actual set point of

temperature, when the process value goes below the limit it cut off the COMPRESSOR.

Temperature low cut off (°C.TLC2) means the value you entered plus actual set point of

temperature, when the process value goes below the limit it cut off the MAIN CONTACTOR.

SOFTWARE

21-CFR PART 11 COMPLIANCE SOFTWARE

Browser Based Software

Unlimited Equipment Connectivity

Secured audit trail (User, Equipment, Alarm SMS, Events).

Real time analysis

Online/Offline Graphical analysis for temp. and humidity

Open door with reason master

Automatically calculate MKT ( Mean Kinetic Temperature

OR

Material of Construction: Standard model or G.M.P. Model

Insulation: 3” Thick PUF Insulation.

Air Circulation: Blower to have uniformity of condition under chamber loaded condition.

Observation Door: Inside observation glass door with special neoprene gasket.

Page 26: Final Tender Form 2011-12 Auto Saved)

Handle / hinges: Imported French make handle and hinges for positive sealing with lock

and key arrangement.

Port Hole: 50 mm Port Hole with rubber seal to insert sensors for validation purpose.

Lighting: Interior illumination for working area.

Heating System: U shaped S.S. Nichrome wire air heaters.

Controller System: PLC Based control System

PHOTOSTABILITY EFFECT: Fluorescent Tubes for day light effect and UV tubes for ultra

violet ray in accordance to the ICH guidelines requirement of a lighting energy mounting to

1.2 W x 106 L x H (1.2 mil Lux hours) and an integrated UV energy share of 200 watts

hours/m2.

Refrigeration System: CFC Free Emerson (Kirloskar) Compressor with R 134 A (Eco

Friendly) refrigerant having state of art. By pass system for continues run of compressor

Stand by Refrigeration System: Ready for use refrigeration system in case the regular

system fails. Complete with Compressor, Condensor, Evaporator and Other Accessories with

Gas Charging.

Control System Imported Japanese Fuji make Microprocessor based PID controller with

digital display of temperature in deg. Centigrade and Humidity in Direct % RH.

Printer Interface: Facility to print records on printer with set values, actual values, date and

time with variable print time interval.

PC Interface: Facility to connect to a PC for data management with software. Compliance

to 21 CFR part 11.

Safety Features:

o Dedicated safety controller with separate sensor to cut off the supply in case of overshoot

and undershoot of Temperature giving audio visual alarm.

o Additional safety thermostat (Jumo German Make) to cut off the supply in case of

overshoot of temperature.

o 2 min. compressor ‘ON’ delay timer to safe guard the compressor.

Standard Model: Inside S. S. 304 mirror polished & Outside powder coated M.S.

G.M.P. Model: Inside S. S 316 mirror polish & Outside S. S 304 dull smooth buff.

Capacity: 400 Liters

Temperature Range 20 0 C to 600 C

Temperature Set Point 25 0 C

Temperature Accuracy ± 0.2 0 C

Temperature Uniformity ± 2 0 C

Complete with: Indication of light intensity in Lux. (Lux meter + UV Meter.)

Common for all the parties

A good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

OR

Any party with the specifications equivalent or higher than above mentioned for Photo Stability Chamber can also be considered

9. Ultra Sonic Homogenizer One

Page 27: Final Tender Form 2011-12 Auto Saved)

Ultrasonic Power output: 750W

Ultrasonic Frequency: 20kHz

13 mm (1/2”) probe with threaded end and replaceable tip (Tips are autoclavable)

Extra probe for the volume ranging from 250µL to 1L

Automatic tuning, Energy (joules) Monitor, energy controller, digital wattmeter controller,

Temperature controller, Microprocessor based programmable LCD Screen with user

prompts alpha numeric display

Programmable process timer

Variable amplitude controller,

Full functional pulsar –ON and OFF cycle independently controllable from 1 to 59

seconds

Overload protection circuit

Remote actuation connector

Jack type sample holder.

Switch: for hands-free operation,10’ cable with plug.

Sound abating cabinet

Instruction manual

Tool kit

Common for All the PartiesA good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Ultra sonic

Homoginizer can also be considered

10. Inverted Microscope One Stand: Stand: Rugged and sturdy Inverted stand. It should have low positioned co-axial

coarse and fine focus knobs. It should have built-in electronic power supply for 12V / 30W

illuminator with conveniently positioned ON/OFF switch and regulating knob.

Optics: Microscope should have infinity colour corrected optics with high contrast and

resolution. The optical beam path should be ‘V’ shape with change over beam reflector for

observation and photography. The microscope should be suitable for bright field and phase

contrast techniques in transmitted light.

Nosepiece: Focusable Quadruple revolving objective nosepiece mounted on ball bearing

with highly precise click stops.

Stage: Mechanical stage with X-Y Movement, fixed stage plate with attachable

mechanical stage with inserts for various culture plates and flasks. Common mounting frame

to hold petri dishes of size 35-60mm and for slides. Mounting frame for microtest plates 60,72

and 120 positions for HLA with adhesive scales should be quoted. Auto ON/OFF switch on

stage for Halogen or LED Light for saving life of bulb. Automatically switched off after

15 minutes if unused.

Binocular Tube: Integrated binocular tube 45 with field of view 20mm on the microscope

stand with swiveling eyepiece tube.

Page 28: Final Tender Form 2011-12 Auto Saved)

Illumination: Built-in illumination to the stand with 12V / 30W tungsten halogen lamp. The

lamp should be easily changeable. Filter slider for day light and green filter. The power

supply for the lamp should be integrated in the stand and should be suitable for 220 - 240V

50Hz power supply. OR LED bulb of 3W white light.

Condenser: Long working Condenser 0.4 with built-in aperture diaphragm for bright field

and phase contrast. The condenser should be suitable for magnification range from 40x to

400x.

Objectives: Plan Achromatic long working distance objectives with high contrast and

resolution

4x/0.12 Ph

10x/0.25 Ph 1

20x/0.30 Ph 1

40x/0.50 Ph 1 or 2

Eyepieces: Wide field focusing eyepieces with minimum 20mm field of view with soft

rubber soft eyecups and is suitable for spectacle wearers. It should be marked with ± 5

diopter settings. The eyepieces should be suitable for graticule insertion.

Camera: 5 Megapixel CMOS Camera with pixel size of 2.2µm X 2.2µm. Integration with

computer through USB. Slot for SD Card, 4GB Storage card, with C-Mount Adapter.

Software: Image analysis software integrated with above camera. Software should

capable to operate above mentioned camera. Live imaging & measurement functions for

captured image. Basic application like colour adjustment, measurement (line, length, circle).

Scale on image.

Note: Fluorescence upgradable

or

Frame: Microscope stand with sextuple revolving nosepiece and two step light path

selector (observation: left side port= 100:0, 20:80), corresponded to near-infrared (700-

1000nm), relay lens, prism, dust proof glass-AW multi coated

Filters: Interference green contrast filters 45mm dia.

Nosepiece: Focusable Quadruple revolving objective nosepiece mounted on ball bearing

with highly precise click stops.

Stage: Stage extension plate. Plain stage. Attachable mechanical stage with flexible right-

hand vertical low drive controls, including scales for 96 micro test plates. Terasaki-plate

holder (72-well/60-well) for IX-MVR, including position scales. Slide glass holder for IX-MVR

Petri-dish holder (65mm dia. hole) for IX-MVR, including adapters with 54mm dia.hole

and35mm dia. hole

Binocular Tube: Binocular tube

Illumination: Illumination pillar for 30WHAL with one filter holder (45mm dia.), including

fixing screws AB5X35SA (4 pcs). Power supply for 30W halogen lamp with output cable

(0.64m) (Made in Philippines) Corresponded to WEEE regulation. 30W Halogen bulb (Philips

No. 5761) for BX40/41/45,IX50/51, CH40,CX31/40/41,CKX31/41, CK30/40,SZX2-

ILLK/ILLB/ILLD (Made in Germany) with power cord and Dust cover Type 020 for IX2,MVX10

( L 620mm x W 250mm x H 660 mm)

Condenser: Long working Condenser 0.4 with built-in aperture diaphragm for bright field

Page 29: Final Tender Form 2011-12 Auto Saved)

and phase contrast. The condenser should be suitable for magnification range from 40x to

400x.

Objectives: Acromat phase (pre-center) objective 10X/0.25, W.D. 8.8mm. Long working

distance achromat phase contrast (pre-center) objective 20X/0.4, WD 3.2. Long working

distance achromat phase contrast (pre-center) objective 40X/0.55, WD 2.2.

Eyepieces: Widefield eyepiece 10X, focusable with eyecups and suitable for spectacle

wearers.

Camera: 5 mega-pixel CMOS Color-Bayer Mosaic,10-bit, non-cooled, USB 2.0., with C

mount adapter

Software: Image analysis software integrated with above camera. Live imaging &

measurement functions for captured image. Basic application like colour adjustment,

measurement (line, length, circle). Scale on image.

Note: Fluorescence upgradable

or

Optical system: CFI60 infinity system, parfocal distance 60mm

Eyepiece tube: Siedentopf-type trinocular tube (light distribution, bino/photo: 100/0,

0/100)

Eyepiece tube: Interpupillary distance: 50–75 mm, Eyepoint height: 400mm from table,

Inclination: 45° from horizon

Nosepiece: Quintuple nosepiece, backward-facing type

Plain stage: Stage size: 170 x 225 mm, Stage height: 195mm from table, Acrylic window

provided, Auxiliary stage attachable

Illumination: Pre-centered 6V-30W halogen lamp, Filter frame (accepts 2 filters), Heat

absorbing filter and diffuser (Upgradable to 50W Epi fluorescence)

Attachable mechanical stage: Stage movement: 126 x 80 mm Accepts several micro-

test plate holders

Eyepiece lens: 10X

Condenser: ELWD condenser: N.A. 0.3 (O.D. 75mm) Non-centerable Phase Slider

Objectives:Apodized Phase Contrast Objective Lens, Achromat 4X, Achromat 10X,

Achromat 20X, andAchromat 40Xwith cover glass correction 0-2mm

Camera: 5 mega-pixel scientific CCD camera, USB 2.0., with C mount adapter

Note: Fluorescence upgradable

Common for All PartiesA good quality Electrical stabilizer, IBM compatible Personal desktop computer and laser printer with all latest softwares installed, along with UPS All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

OR

Any party with the specifications equivalent or higher than above mentioned for Inverted Microscope can also be considered

11. Water Purification System OnePre-filtration System, with:

It should consist of 5 & 1 micron depth filter with retention efficiency greater than 80%,

Page 30: Final Tender Form 2011-12 Auto Saved)

enclosed in a polypropylene housing.

DC diaphragms pump to boost water pressure.

Pressure gauges to monitor the health of pre-filter cartridge.

Low pressure switch & high pressure switch to cut-off the system when this there is no

water in the inlet.

Unit should operate at < 50 decibel and should be wall mountable to save lab space.

Analytical Water Purification System with three stage purification,

First Stage: Should consist of a single pretreatment pack having 1 micron depth filter,

anti-scaling compound and silver impregnated activated carbon. The pack should also

have RFID tag for proper traceability.

Second Stage: Should consist of polyamide composite reverse osmosis membrane

with rejection efficiency of 94 – 99%.

Third Stage: Should consist of self-regenerating electrodeionisation module for removal

of ions and organics from RO water. The electrodeionisation module should have an

inbuilt mechanism of preventing scale formation at cathode.

System should have resistivity meter before and after RO module to measure the

percentage rejection. The percentage rejection monitored should be displayed on the

screen.

Built in coaxial type resistivity meter with a cell constant of 0.01 cm-1 and 0.10C

accuracy thermistor to measure resistivity of final purified water.

Should have a safety mechanism after RO to divert low quality permeate to drain and

thus protect downstream purification cartridges.

Should have pump with unique temperature feedback mechanism to ensure constant

flow rate irrespective of external temperature.

Should have an explicit 8 line alphanumeric display for viewing quality parameters and

any error / alarms.

System should be able to handle feed water with following parameters:

Conductivity: 1800 – 2000 µS/cm

Fouling Index (SDI): Upto 12

Total Chlorine: Upto 3 ppm

Product Water Quality:

Flow rate: 3 L/hr

TOC: < 30 ppb

Resisitivity: > 5 MΩ·cm

Conductivity: < 0.2 µS/cm

Silica Content: > 99.9 % retention

Reservoir: Cylindrical PE reservoir with 30 L or better capacity and sensor rod float

switch

Ultrapure Water Purification System, with: Should consist of single Purification pack

tailored to specific feed water source containing mixed bed ion exchange resin/ micro

filter / activated carbon. This should be followed by 0.22 um membrane filter in disc

stacking.

Should have easy plug and use design of purification cartridges

Page 31: Final Tender Form 2011-12 Auto Saved)

Built in coaxial type resistivity meter with a cell constant of 0.01 cm-1 and 0.10C

accuracy thermistor to measure resistivity of final purified water.

Automatic recirculation when system is not in use, to prevent contamination.

Should have a Preset of fixed volume dispense

Should have a point of use 0.22 micron filter in disc stacking having higher surface

area for filtration.

4 line alphanumeric colored control display showing product water resistivity

/conductivity, product water temperature, error & maintenance messages etc.

Product Water Quality

Flow rate: 1.0 ml/min.

TOC: <10 ppb

Resistivity/Conductivity: 18.2 MΩ·cm / 0.05 µS/cm

Particles: < 1 P/ml

Bacteria Level: < 0.1 cfu/ml

Common for All Parties

A good quality Electrical stabilizer, All necessary accessories apart from mentionedmust be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Inverted

Microscope can also be considered

12. Ultracentrifuge One RCF(x g): more than 1, 00, 000g

Speed control accuracy(rpm): ±50(5000 to max speed)

Max capacity: 1.5ml X 12 tubes

Timer: 1 min to 99 hrs and 59 min, with HOLD function, RTC Function

Vacuum system: oil rotary vacuum pump and oil diffusion pump. Pressure range

under 1.3 Pa

Rotor temp control range: -20-40˚C (1˚C increments)

Rotor cooling method: thermo module cooling system

Screen display: adjustable LCD display

Rotor setting method: quick setting

Operational noise: 46(db(A)*)

Drive unit warranty: 5 years

Common for All Parties

A good quality Electrical stabilizer, All necessary accessories apart from mentionedmust be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Inverted

Microscope can also be considered

13. Physiological data acquisition system for One recording ECG and NIBP

Software package including lession, ECG, NIBP, etc.

Data Acquisition Unit with USB Cable, DC Adapter and Cord

Page 32: Final Tender Form 2011-12 Auto Saved)

2 x Electrode Lead Sets

Disposable Electrodes (100/pk)

Abrasive Pads (10/pk)

Needle Electrode Bipolar

Needle electrode Unipolar 1.5 cm

Tail cliff apparatus for measuring noninvasive blood pressure:- Noninvasive BP-Sm.

Animal Tail 110/220 V, Tail Cuff/Sensor (specify 9.5/11/13 mm), Variable Range Force

Transducer

All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

OR

Any party with the specifications equivalent or higher than above mentioned for Physiologicaldata acquisition system for recording ECG and NIBP can also be considered

14. Sterotaxic Apparatus One Digital Lab Standard with LED Display

Speed Control Dial, Optional, 220 Volt

Motor Support w/Table Clamp

Drill Bit-1.35 mm

Mouse Adaptor

Rota Rod, mice and rats

Quattro 4 in 1 System, 220 Volt

Steel Brain Matrix, 1.0mm, Coronal, 40-75g

Steel Brain Matrix, 1.0mm, Coronal, 175-300gRodent Surgery Table

All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Sterotaxic

apparatus can also be considered

15. Digital Automatic Karl Fisher Titration apparatus One It should work For Solid, Liquid or Gas Sample

The Microprocessor based circuitry

The Key Board to feed data such as weight of sample in mgs, volume in ml and density

etc.

The Titer factor should be automatically calculated and presented on display

The End point detection by red lamp or alarm

The Moisture content should be calculated and displayed automatically in total moisture,

ppm or in percentage.

The instrument should provided with Connector for printer

All necessary accessories apart from mentioned must be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Digital Automatic

Karl Fisher titration apparatus can also be considered

Page 33: Final Tender Form 2011-12 Auto Saved)

16. Polarimeter One Dual Scale

Temperature display

Optical density display

Temperature compensation: None, Sugar, Quartz

LED/ Interference filter

Printer and PC connection

Bright Display

Technical Specification:

Angular oA ISS oZ

Range -90 to +90 -225 to +225

Resolution 0.01 0.01

Accuracy ±0.02 ±0.05

Beam Diameter: 4.0 mm

Max. Tube length: 220 mm

Reading time: 15 Sec.

Temperature range: 5-40 oC

Common for All PartiesA good quality Electrical stabilizer, All necessary accessories apart from mentionedmust be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Polarimeter can

also be considered

17. Refractometer One Both refractive index and Brix scales with monitoring and displaying of prism temperature

on the integral display.

Water bath connection for temperature control with 4 decimal places

Brix Disperson measurement of solids material such as glass, contact lenses and fiber

optics.

It should be supplied with a glass calibration plate, contact liquid and instruction manual

and is packed in a hard flight case for easy transportation and storage. Range-1.30-1.70 RI, 0-95o

Resolution-0.0005, 0.25o Brix

Operating Temperature-5-70 oC Temperature Resolution-0.1o

Temperature Accuracy-±1oC

Storage/Ambient temperature - 5-40oC

Power Source - 1* AA alkaline 1.5 V dry cell

Approx. life 122 months continuous usage

Common for All PartiesA good quality Electrical stabilizer, All necessary accessories apart from mentioned

Page 34: Final Tender Form 2011-12 Auto Saved)

must be included with IQ/OQ/PQ documents

ORAny party with the specifications equivalent or higher than above mentioned for Refrectometer

can also be considered

Page 35: Final Tender Form 2011-12 Auto Saved)

UNDERTAKING

Undertaking to be given by the tenderer for supply of Scientific Equipments / Instrument Whereas,

The Registrar, Saurashtra University, Rajkot-360 005, has called for tenders for supplies as per the

tender form

I/We hereby offer our tender at the rates given in the tender form duly filled in and signed by me/us

and hereby also affix my/our signature(s) below this tender voluntary and full acceptance of all the

terms and conditions of this tender, which shall be the agreement between the above tender calling

authority and myself/us.

Signature of the Supplier: ______________________________________

Name of the Supplier: ______________________________________

Capacity in which signing: _____________________________________

Full address of the Supplier: ______________________________________

______________________________________

______________________________________

Place: With seal/stamp:Date: