final designated substances survey report · survey report women’s residence 674 dundas street...

65
© 2017 Pinchin Ltd. FINAL Designated Substances Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55 John Street, 2 nd Floor Toronto, Ontario, M5V 3C6 Attention: Sara Reid Environmental Project Manager July 20, 2017 Pinchin File: 113698.002

Upload: others

Post on 08-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

© 2017 Pinchin Ltd.

FINAL

Designated Substances Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario

Prepared for:

The City of Toronto Facilities Management 55 John Street, 2nd Floor Toronto, Ontario, M5V 3C6

Attention: Sara Reid Environmental Project Manager

July 20, 2017

Pinchin File: 113698.002

Page 2: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page ii

Issued to: Contact: Issued on: Pinchin file: Issuing Office: Primary Contact:

The City of Toronto Sara Reid Environmental Project Manager July 20, 2017 113698.002 50 Wellington Street East, Suite 200, Toronto, ON M5E 1C8 Juliette McIntyre

Author: Tanya Stanisic, B.Sc. Hons. Project Manager 647.502.6665 [email protected]

Reviewer: Juliette McIntyre Senior Project Manager 416.368.6555 ext. 1910 [email protected]

Page 3: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page iii

EXECUTIVE SUMMARY

The City of Toronto (Client) retained Pinchin Ltd. (Pinchin) to conduct a Designated Substance survey of

Women’s Residence located at 674 Dundas Street West, Toronto, Ontario. The survey was performed on

October 18, 2016.

The objective of the survey was to document the locations of specified Designated Substances,

polychlorinated biphenyls (PCBs) and mould, evaluate their condition, and develop corrective action plans

as required for the purposes of long term management. The results of this survey are not intended for

construction, renovation, demolition or project tendering purposes.

The survey area consisted of the entire building. The building was occupied at the time of the survey.

SUMMARY OF FINDINGS

Asbestos: Asbestos-containing materials (ACM) were confirmed or assumed to be present as follows:

Roofing materials

Exterior window caulking.

Lead: Lead was confirmed present in select paints and is present in emergency light batteries.

Silica: Crystalline silica is present in concrete, mortar, brick, masonry, ceramics, etc., where present in the

building.

Mercury: Mercury vapour is present in fluorescent lamps throughout the building. Liquid mercury is

present in thermostat ampules throughout the building.

Polychlorinated Biphenyls (PCBs): PCBs may be present in light ballasts.

Mould: Mould-impacted materials were not found.

SUMMARY OF RECOMMENDATIONS

The following is a summary of significant recommendations; refer to the body of the report for detailed

recommendations.

1. Perform a pre-construction survey and remove all ACM prior to alteration or maintenance

work or if ACM may be disturbed by the work.

2. Remove and dispose of PCB ballasts and mercury-containing items when taken out of

service.

Page 4: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page iv

3. Follow appropriate safe work procedures when handling or disturbing asbestos, lead,

mercury and silica.

4. Remediate the following materials:

o Remove pink flaking paint on the 2nd Floor of the Main Stairwell (Location S1) using

Type 2a Lead Operations.

Please refer to Section 4.0 of this report for detailed recommendations regarding administrative actions.

This Executive Summary is subject to the same standard limitations as contained in the report and must be read in conjunction with the entire report.

Page 5: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page v

TABLE OF CONTENTS

1.0  INTRODUCTION AND SCOPE ....................................................................................................... 1 

1.1  Scope of Survey ................................................................................................................... 1 

2.0  BACKGROUND INFORMATION ..................................................................................................... 2 

2.1  Building Description .............................................................................................................. 2 

3.0  FINDINGS ........................................................................................................................................ 2 

3.1  Inaccessible Locations ......................................................................................................... 2 3.2  Asbestos ............................................................................................................................... 2 3.3  Lead ...................................................................................................................................... 8 3.4  Silica ..................................................................................................................................... 9 3.5  Mercury ............................................................................................................................... 10 3.6  Polychlorinated Biphenyls .................................................................................................. 10 3.7  Mould .................................................................................................................................. 10 

4.0  RECOMMENDATIONS .................................................................................................................. 10 

4.1  General ............................................................................................................................... 10 4.2  Remedial Work ................................................................................................................... 10 4.3  On-going Management and Maintenance .......................................................................... 11 

5.0  LIMITATIONS ................................................................................................................................. 12 

6.0  REFERENCES ............................................................................................................................... 12 

APPENDICES

APPENDIX I   Drawings 

APPENDIX II-A   Asbestos Analytical Certificates 

APPENDIX II-B   Lead Analytical Certificates 

APPENDIX II-C   PCB Analytical Certificates (No Information to Report) 

APPENDIX III   Methodology 

APPENDIX IV   Survey Form 

Page 6: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 1 of 12

1.0 INTRODUCTION AND SCOPE

The City of Toronto (Client) retained Pinchin Ltd. (Pinchin) to conduct a Designated Substances Survey of

Women’s Residence, located at 674 Dundas Street West, Toronto, Ontario.

The survey was performed by Tanya Stanisic, B.Sc. Hons., Project Manager, on October 18, 2016. The

surveyor was accompanied by a representative of the Women’s Residence during the survey. The

building was occupied at the time of the survey.

The objective of the survey was to document any changes in condition and quantity of specified

Designated Substances, polychlorinated biphenyls (PCBs) and mould, identified in the previous

Designated Substances Survey (Pinchin File 103037), and develop corrective action plans as required.

This survey is only to be used for the purposes of long term management and routine maintenance. The

results of this survey are not to be used for construction, renovation, demolition or project tendering

purposes.

1.1 Scope of Survey

For the purpose of the survey and this report, hazardous building materials include the following

Designated Substances:

Asbestos

Lead

Silica

Mercury

The survey also included:

Polychlorinated Biphenyls (PCBs)

Mould

The following Ontario Designated Substances are not typically found in building materials in a

composition/state that is hazardous and were not included in this survey:

Arsenic

Acrylonitrile

Benzene

Coke oven emissions

Ethylene oxide

Isocyanates

Page 7: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 2 of 12

Vinyl chloride monomer

2.0 BACKGROUND INFORMATION

2.1 Building Description

Item Details

Building Use Shelter and Housing Services

Number of Floors/Levels Four stories plus one below grade

Total Area of Building Approximately 10,000 square feet

Year of Construction   1911

Structure Structural steel, concrete

Exterior Cladding Pre-cast concrete, brick

HVAC Forced-Air, Boiler

Roof Built-up roofing

Flooring Vinyl floor tiles, vinyl sheet flooring, ceramic, concrete

Interior Walls Drywall, plaster, concrete

Ceilings Drywall, acoustic ceiling tiles, plaster

3.0 FINDINGS

3.1 Inaccessible Locations

The following rooms or areas of the building were not accessible to the surveyor and are therefore not

included in the report:

Area or Room Reason

Location E-1, Elevator Pit Only Accessible by Elevator Maintenance Personnel

3.2 Asbestos

3.2.1 Suspect Building Materials Not Found

The following types of building materials may historically contain asbestos but were not observed in the

building and are not discussed in the report findings:

Page 8: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 3 of 12

Spray-applied fireproofing or thermal insulation

Vermiculite

Asbestos cement products

Firestopping

3.2.2 Texture Finishes (Acoustic/Decorative)

Texture finish is located on the plaster ceiling in the Dining Room (Location 1-05). The decorative texture

finish was sampled during this survey (samples 2016-A0001A-C) and determined not to contain asbestos.

Photo 1: Non-asbestos decorative texture finish on the ceiling

in the Dining Room (Location 1-05).

3.2.3 Thermal Systems Insulation (TSI)

3.2.3.1 Pipe Insulation

Parging cement is present on pipe fittings (elbows, valves, tees, hangers etc.) of various pipe systems in

the Basement Storage Room (Location B-27) (samples 2014-A0005A-C). Parging cement was sampled

and determined not to contain asbestos.

Remaining pipes observed throughout the building were insulated with non-asbestos insulation (e.g.

fibreglass, Armaflex).

3.2.3.2 Duct Insulation

Ducts are either uninsulated or insulated with non-asbestos fibreglass and jacketed with either canvas or

foil.

3.2.3.3 Mechanical Equipment Insulation

Mechanical equipment is insulated with non-asbestos fibreglass or not insulated.

Page 9: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 4 of 12

3.2.4 Acoustic Ceiling Tiles

Three distinct types of acoustic ceiling tile are present in the assessed area, as follows:

Size, Type, Pattern, Photo #

Locations Sample Number Asbestos Type

24” x 48” lay-in, fissure and pinhole pattern, Photo 2

*See Survey Form in Appendix IV for Locations

2015-A0001A-C None Detected

24” x 48” lay-in, small and large pinhole pattern, Photo 3

*See Survey Form in Appendix IV for Locations

2014-A0006A-C None Detected

24” x 48” lay-in, widthwise fissure and pinhole pattern, Photo 4

*See Survey Form in Appendix IV for Locations

2015-A0002A-C None Detected

Photo 2: Non-asbestos ceiling tile, 24’x48’ fissure and pinhole

pattern (samples 2015-A0001A-C).

Photo 3: Non-asbestos ceiling tile, 24”x48” small and large

pinhole pattern (samples 2014-A0006A-C).

Photo 4: Non-asbestos ceiling tile, 24”x48” widthwise fissure and pinhole pattern (samples 2015-A0002A-C).

3.2.5 Plaster

Plaster is present on walls and ceilings in the building. Plaster does not contain asbestos (samples 2014-

A0008A-G).

Page 10: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 5 of 12

3.2.6 Drywall Joint Compound

Drywall (gypsum board) and drywall joint compound is present as a wall and ceiling finish throughout the

building. Nine samples of drywall joint compound were previously collected (samples 2012-A0002A-C,

2013-14375-A17-03-A-C, 2014A-0003A-C) and determined not to contain asbestos.

3.2.7 Vinyl Sheet Flooring

Vinyl sheet flooring is present as follows:

Pattern, Colour and Photo Number

Paper Backing (Yes/No)

Locations Sample Number

Asbestos Type

Beige/Tan/White and Blue Lines, Photo 5

No *See Survey Form in Appendix IV for Locations

2015-A0006A-C

None Detected

Grey with blue flecks, Photo 6

No *See Survey Form in Appendix IV for Locations

2015-A0003A-C

None Detected

Grey, Photo 7 No *See Survey Form in Appendix IV for Locations

2015-A0004A-C

None Detected

Orange/Brown, Photo 8

No *See Survey Form in Appendix IV for Locations

2015-A0007A-C

None Detected

Orange, Photo 7 No *See Survey Form in Appendix IV for Locations

2015-A0005A-C

None Detected

Photo 5: Non-asbestos vinyl sheet flooring beige/tan/white and

blue lines (samples 2015-A0006A-C).

Photo 6: Non-asbestos vinyl sheet flooring, grey with blue

flecks (samples 2015-A0003A-C).

Page 11: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 6 of 12

Photo 7: Non-asbestos vinyl sheet flooring, grey and orange

(samples 2015-A0004A-C, and 2015-A0005A-C).

Photo 8: Non-asbestos vinyl sheet flooring, orange/brown

(samples 2015-A0007A-C)

3.2.8 Vinyl Floor Tile and Mastic

Vinyl floor tiles are present as follows:

Size, Pattern, Colour and Photo Number

Locations Sample Number

Asbestos Type (tile)

Asbestos Type (mastic)

12” x 12”, Green *See Survey Form in Appendix IV for Locations

2014-A0001A-C

None Detected

None Detected

12” x 12”, Grey with grey flecks, Photo 9

*See Survey Form in Appendix IV for Locations

2014-A0002A-C

None Detected

None Detected

12” x 12”, Beige, Photo 10

*See Survey Form in Appendix IV for Locations

2014-A0004A-C

None Detected

None Detected

12” x 12”, Dark blue mottled, Photo 11

*See Survey Form in Appendix IV for Locations

2015-A0010A-C

None Detected

None Detected

12” x 12”, Orange mottled, Photo 11

*See Survey Form in Appendix IV for Locations

2015-A0009A-C

None Detected

None Detected

12” x 12”, Yellow mottled, Photo 11

*See Survey Form in Appendix IV for Locations

2015-A0008A-C

None Detected

None Detected

12” x 12”, Cream with beige flecks, Photo 12

*See Survey Form in Appendix IV for Locations

2015-A0011A-C

None Detected

None Detected

12” x 12”, Blue mottled, Photo 13

*See Survey Form in Appendix IV for Locations

2015-A0012A-C

None Detected

None Detected

12” x 12”, Grey with white streaks, Photo 14

*See Survey Form in Appendix IV for Locations

2015-A0013A-C

None Detected

None Detected

12” x 12”, Purple *See Survey Form in Appendix IV for Locations

2015-A0015A-C

None Detected

None Detected

Page 12: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 7 of 12

Photo 9: Non-asbestos VFT (samples 2014-A0002A-C).

Photo 10: Non-asbestos VFT (samples 2014-A0004A-C).

Photo 11: Non-asbestos VFT (samples 2015-A0008A-C, 2015-

A0009A-C and 2015-A0010A-C).

Photo 12: Non-asbestos VFT (samples 2015-A0011A-C).

Photo 13: Non-asbestos VFT (samples 2015-A0012A-C).

Photo 14: Non-asbestos VFT (samples 2015-A0013A-C).

3.2.9 Assumed Asbestos Materials

roofing, felts and tar

concrete floor levelling compound

elevator and lift brakes

electrical components or wiring within control centers, breakers, motors or lights,

insulation on wiring

insulation under metal clad boilers and vessels

vermiculite in concrete block wall cavities

Page 13: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 8 of 12

adhesives and duct mastics

levelling compound

sealants, caulking, and pPutty

paper products under wood flooring

soffit and fascia boards at elevated heights

mechanical packing, ropes and gaskets

fire resistant doors

3.3 Lead

3.3.1 Paints

Two paint samples were collected during this survey. The table below includes the two samples collected

during this assessment, and sample previously collected.

Sample Number

Colour, Substrate Description

Locations Lead (%)

2012-Pb01 Yellow paint on masonry and plaster wall

*See Survey Form in Appendix IV for Locations

0.14

2012-Pb02 Yellow paint on drywall *See Survey Form in Appendix IV for Locations

<0.009

2012-Pb03 Beige paint on masonry wall

*See Survey Form in Appendix IV for Locations

<0.009

2016-L0001, Photo 15

Pink paint on plaster *See Survey Form in Appendix IV for Locations

0.1%

2016-L0002 Blue paint of drywall *See Survey Form in Appendix IV for Locations

<0.006%

Pink paint was flaking/peeling in the following areas on the following items:

Approximately 2 square feet of pink paint, containing 0.1% of lead by weight, was

observed to be peeling from the wall on the 2nd Floor landing in the Main Stairwell

(Location S1).

Page 14: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 9 of 12

Photo 15: Damaged wall paint in Location S1.

3.3.2 Lead Products and Applications

Lead-containing batteries are present in emergency lighting present in the building.

Photo 16: Emergency lighting with lead containing batteries is located throughout the building.

3.3.3 Assumed Lead Materials

Lead may be present in a number of materials which were not assessed and/or sampled. The following

materials, where found, should be considered to contain lead.

electrical components, including wiring connectors, fibre optic cable sheathing, grounding

conductors, and solder

glazing on ceramic tiles

3.4 Silica

Crystalline silica is assumed component of the following building materials where present in the building:

poured or pre-cast concrete

masonry and mortar

ceramic tiles, grout

plaster

Page 15: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 10 of 12

3.5 Mercury

3.5.1 Lamps

Mercury vapour is present in fluorescent lamps throughout the assessed area.

3.5.2 Mercury-Containing Devices

Mercury is present as a liquid in thermostats found throughout the building.

3.6 Polychlorinated Biphenyls

3.6.1 Lighting Ballasts

The building has not been comprehensively re-lamped with new energy efficient light ballasts and lamps,

and as such, a percentage of light ballasts may be pre-1980 and contain PCBs.

3.6.2 Transformers

All transformers in the building are dry type transformers and do not contain PCB-containing dielectric

fluids.

3.7 Mould

Visible mould growth was not found in the assessed area.

4.0 RECOMMENDATIONS

4.1 General

Perform a detailed intrusive survey prior to building renovation or demolition operations. The survey

should include; destructive testing (i.e. coring and/or removal of building finishes and components), and

sampling of materials not previously tested (i.e. roofing materials, caulking, mastics).

4.2 Remedial Work

Perform the following remedial work to comply with existing regulations, due to the condition and location

of the material:

Material and Quantity Location Recommended Procedure

Delaminating pink paint, approximately 2 SF, Photo 15

Location S1 Type 2a Lead Operations

Page 16: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 11 of 12

4.3 On-going Management and Maintenance

The following recommendations are made regarding on-going management and maintenance work

involving the hazardous materials identified.

4.3.1 Asbestos

Perform an assessment of asbestos materials on an annual basis. The next assessment of ACM should

be performed prior to October 2017 to remain in compliance.

Remove all asbestos-containing materials (ACM) prior to alteration or maintenance work or if ACM may

be disturbed by the work. Follow appropriate asbestos precautions for the classification of work being

performed.

Update the asbestos inventory report upon completion of any abatement and removal of asbestos-

containing materials.

4.3.2 Lead

Disturbance of lead in paint and coatings (or other materials) during maintenance activities may result in

over-exposure to lead dust or fumes. The need for work procedures, engineering controls and personal

protective equipment will need to be assessed on a project-by-project basis and must comply with

provincial standards or guidelines. Performing an exposure assessment during work that disturbs lead in

paints and coatings may be able to alleviate the use of some of the precautions specified by these

standards or guidelines.

Lead-containing items (lead-containing batteries) should be recycled when taken out of service.

4.3.3 Silica

Disturbance of silica-containing products during maintenance activities may result in excessive exposures

to airborne silica, especially if performed indoors and dry. Cutting, grinding, drilling or demolition of

materials containing silica should be completed only with proper respiratory protection and other worker

safety precautions that comply with provincial standards or guidelines.

4.3.4 Mercury

Recycle and reclaim mercury from fluorescent light tubes when taken out of service. Do not break lamps.

Light tubes are accepted free of charge at many local recycling depots.

Page 17: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

Women’s Residence, 674 Dundas Street West, Toronto, Ontario Pinchin File: 113698.002

The City of Toronto FINAL

© 2017 Pinchin Ltd. Page 12 of 12

4.3.5 PCBs

When light fixtures are removed from service, examine light ballasts for PCB content. If ballasts are not

clearly labelled as “non-PCB”, or are suspected to contain PCBs; package and ship ballasts for

destruction at a federally permitted facility.

5.0 LIMITATIONS

The work performed by Pinchin was conducted in accordance with the City of Toronto Contract Number

47018468, effective July 31, 2014.

6.0 REFERENCES

The following legislation and documents were referenced in completing the survey and this report:

1. Asbestos on Construction Projects and in Buildings and Repair Operations, Ontario

Regulation 278/05.

2. Designated Substances, Ontario Regulation 490/09.

3. Lead on Construction Projects, Ministry of Labour Guidance Document.

4. Ministry of the Environment Regulation, R.R.O. 1990 Reg. 347 as amended.

5. Surface Coating Materials Regulations, SOR/2005-109, Hazardous Products Act.

6. Silica on Construction Projects, Ministry of Labour Guidance Document.

7. Alert – Mould in Workplace Buildings, Ontario Ministry of Labour.

8. Standard Operating Procedures for Designated Substance Surveys, dated April, 2014,

City of Toronto, Facilities Management.

\\pinchin.com\miss\Job\113000s\113698 CITYOFTORONTO,Multilocation,DSUB,ASSMT\113698.002 CITYOFTORONTO,Shelter,DSUB,ASSMT\Locations\674 Dundas Street West\Report\Final\647 Dundas St W_DSS_2016 FINAL.docx

Template: Master Report City of Toronto, 2016 Designated Substance Survey, Haz, April 21, 2016

Page 18: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX I

Drawings

Page 19: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

NOT ALL KNOWN OR ASSUMED DESIGNATED

SUBSTANCES ARE IDENTIFIED ON THE

DRAWING. REFER TO THE DESIGNATED

SUBSTANCE REPORT FOR A COMPLETE LIST

OF KNOWN AND ASSUMED DESIGNATED

SUBSTANCES.

NO ACCESS TO ROOMNAR

1-01LOCATION NUMBER

ASBESTOS BULK SAMPLE

LEAD BULK SAMPLE

NO ACCESS TO ROOM/AREANAR

B-01

B-02

B-03

B-04

B-05 B-06

B-07a

B-08

B-09

B-10

B-11

B-07b

B-12

B-13

B-14

B-15

B-16

B-17

B-18

B-20

B-19

B-21

B-22

B-24

B-23

B-25

B-26

B-27

E1

S1

B-28

S2

NAR

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:

NTS

CITY OF TORONTO

WOMEN'S RESIDENCE

674 DUNDAS STREET

TORONTO, ONTARIO

DESIGNATED SUBSTANCES

SURVEY

BASEMENT

2016/11/18

BC

TS

113698.002

1 OF 5

Page 20: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

1-01

1-03

1-02

1-04

1-05

1-06

1-07

1-09

1-08

1-10

1-12

1-13

1-11

1-19

1-20

1-21

1-22

1-18

1-17

1-16

1-14

1-15

S1

E1

S2

2016-A0001C

2016-A0001A,B

NAR

NOT ALL KNOWN OR ASSUMED DESIGNATED

SUBSTANCES ARE IDENTIFIED ON THE

DRAWING. REFER TO THE DESIGNATED

SUBSTANCE REPORT FOR A COMPLETE LIST

OF KNOWN AND ASSUMED DESIGNATED

SUBSTANCES.

NO ACCESS TO ROOMNAR

1-01LOCATION NUMBER

ASBESTOS BULK SAMPLE

LEAD BULK SAMPLE

NO ACCESS TO ROOM/AREANAR

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:

NTS

CITY OF TORONTO

WOMEN'S RESIDENCE

674 DUNDAS STREET

TORONTO, ONTARIO

DESIGNATED SUBSTANCES

SURVEY

GROUND FLOOR

2016/11/18

BC

TS

113698.002

2 OF 5

Page 21: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

2-01

2-02

2-03

2-04

2-05 2-06 2-07

2-08

2-09

2-12

2-13

2-10

2-11

2-14

2-15

2-16

2-17

2-18

2-19

2-20

2-21

2-22

2-24

2-25

2-23

2-26

S2

S1

E1

L0001

L0002

NAR

NOT ALL KNOWN OR ASSUMED DESIGNATED

SUBSTANCES ARE IDENTIFIED ON THE

DRAWING. REFER TO THE DESIGNATED

SUBSTANCE REPORT FOR A COMPLETE LIST

OF KNOWN AND ASSUMED DESIGNATED

SUBSTANCES.

NO ACCESS TO ROOMNAR

1-01LOCATION NUMBER

ASBESTOS BULK SAMPLE

LEAD BULK SAMPLE

NO ACCESS TO ROOM/AREANAR

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:

NTS

CITY OF TORONTO

WOMEN'S RESIDENCE

674 DUNDAS STREET

TORONTO, ONTARIO

DESIGNATED SUBSTANCES

SURVEY

SECOND FLOOR

2016/11/18

BC

TS

113698.002

3 OF 5

Page 22: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

3-01 3-02 3-03 3-04 3-05 3-06 3-07 3-08

3-09

3-10

3-15

3-16

3-17

3-13

3-14

3-11

3-12

3-18

3-19

3-22

3-23

3-213-20

3-24

S2

S1

E1

3-25

NAR

NOT ALL KNOWN OR ASSUMED DESIGNATED

SUBSTANCES ARE IDENTIFIED ON THE

DRAWING. REFER TO THE DESIGNATED

SUBSTANCE REPORT FOR A COMPLETE LIST

OF KNOWN AND ASSUMED DESIGNATED

SUBSTANCES.

NO ACCESS TO ROOMNAR

1-01LOCATION NUMBER

ASBESTOS BULK SAMPLE

LEAD BULK SAMPLE

NO ACCESS TO ROOM/AREANAR

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:

NTS

CITY OF TORONTO

WOMEN'S RESIDENCE

674 DUNDAS STREET

TORONTO, ONTARIO

DESIGNATED SUBSTANCES

SURVEY

THIRD FLOOR

2016/11/18

BC

TS

113698.002

4 OF 5

Page 23: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

4-01 4-02 4-03 4-04 4-05 4-06 4-07 4-08

4-09

4-10

4-15

4-16

4-11

4-13 4-14

4-12

4-19

4-18

4-17

4-24

4-23

4-20

4-21

4-22

E1

S1

S2

NAR

NOT ALL KNOWN OR ASSUMED DESIGNATED

SUBSTANCES ARE IDENTIFIED ON THE

DRAWING. REFER TO THE DESIGNATED

SUBSTANCE REPORT FOR A COMPLETE LIST

OF KNOWN AND ASSUMED DESIGNATED

SUBSTANCES.

NO ACCESS TO ROOMNAR

1-01LOCATION NUMBER

ASBESTOS BULK SAMPLE

LEAD BULK SAMPLE

NO ACCESS TO ROOM/AREANAR

DATE:

DRAWN BY:

LOCATION:

CHECKED BY:

CLIENT:

PROJECT # :

DRAWING:

TITLE:

LEGEND:

SCALE:

NTS

CITY OF TORONTO

WOMEN'S RESIDENCE

674 DUNDAS STREET

TORONTO, ONTARIO

DESIGNATED SUBSTANCES

SURVEY

FOURTH FLOOR

2016/11/18

BC

TS

113698.002

5 OF 5

Page 24: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX II-A

Asbestos Analytical Certificates

Page 25: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

By Polarized Light MicroscopyEPA Method: 600/R-93/116 and 600/M4-82-020

113698.002, City of Toronto, 674 Dundas Street WestProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-Fibrous Components

Attributes

Treatment

Tanya StanisicAttn:Customer: Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Analysis ID: 1622058_PLM

Date Amended: 7/19/2017

Date Reported: 11/9/2016

Date Received: 11/7/2016

Lab Order ID: 1622058

None Detected0001ADecorative Textured Finish (Ceiling) - Dinning Room [1-05]

White, YellowNon FibrousHeterogeneous

Dissolved1622058PLM_1

Other100%

None Detected0001BDecorative Textured Finish (Ceiling) - Dinning Room [1-05]

WhiteNon FibrousHeterogeneous

Crushed1622058PLM_2

Other100%

None Detected0001CDecorative Textured Finish (Ceiling) - Dinning Room [1-05]

WhiteNon FibrousHeterogeneous

Crushed1622058PLM_3

Other100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 1

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Sharon Donald (3)

P-F-002 r15 1/15/2018

Page 26: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX II-B

Lead Analytical Certificates

Page 27: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Pinchin Ltd.50 Wellington Street EastSuite 200Toronto, ON M5E 1C8

Customer:

Analysis ID: 1622063_PBP

Attn: Tanya Stanisic

Date Amended: 7/19/2017

Date Reported: 11/11/2016

Date Received: 11/7/2016

Project: 113698.002, 674 Dundas Street West

Lab Order ID: 1622063

Lab Notes

Description

Lab Sample ID

Sample ID

by Flame Atomic Absorption SpectroscopyEPA SW-846 3050B/6010C/7000B

Concentration

(ppm)(g)

Mass Concentration

(% by weight)

1622063PBP_1

Pink wall paint - stairwell (S1)L000110000.0789 0.10%

1622063PBP_2

Blue wall paint - staff room (2-20)L0002< 550.0725 < 0.006%

Unless otherwise noted blank sample correction was not performed on analytical results. Scientific Analytical Institute participates in the AIHA ELPAT program. ELPAT Laboratory ID: 173190. This reportrelates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. Analytical uncertainty available upon request. The quality control samples run with thesamples in this report have passed all EPA required specifications unless otherwise noted. RL: (Report Limit for an undiluted 50ml sample is 4µg Total Pb).

Taylor Davis (2)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Analyst Laboratory DirectorPage 1 of 1pbRpt_4.0.01_pbp001

L-F-021 r15 3/28/2014

Page 28: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX II-C

PCB Analytical Certificates

(No Information to Report)

Page 29: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX III

Methodology

Page 30: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

The City of Toronto Pinchin File: 113698.002

Methodology Appendix III

© 2017 Pinchin Ltd. Page 1 of 4

1.0 GENERAL

The following survey methodology is based on the requirements of the Standard Operation Procedure for

Designated Substance Surveys, dated April, 2014, provided by the City of Toronto (the “SOP”).

Pinchin conducted a room-by-room survey (rooms, corridors, service areas, exterior, etc.) to identify the

hazardous building materials as defined in Section 1.1. Information regarding the approximate quantity,

location, and condition of hazardous building materials encountered and visually estimated quantities

were recorded on the Survey Form, provided by the City of Toronto, found in Appendix V. The locations

of any samples collected were recorded on small-scale plans, found in Appendix I.

Drawings (i.e., floor plans), previous reports, and Survey Forms, were referenced where provided.

1.1 Limitations on Scope

The survey excludes the following:

Owner or occupant articles (e.g. stored items, furniture, appliances, etc.);

Underground materials or equipment (e.g. vessels, drums, underground storage tanks,

pipes, etc.);

Building envelope, structural components, inaccessible or concealed materials or other

items where sampling may cause consequential damage to the property.

Energized systems (e.g. internal boiler components, elevators, mechanical or electrical

components);

Controlled products (e.g. stored chemicals, operational or process-related substances);

and

Materials not typically associated with construction (e.g. settled dust, spills, residual

contamination from prior spills, etc.).

The survey was limited to non-intrusive testing. Concealed spaces such as those above solid ceilings and

within shafts and pipe chases were accessed via existing access panels only. Pinchin did not conduct

demolition of walls, solid ceilings, structural items, interior finishes or exterior building finishes, to

determine the presence of concealed materials.

1.2 Asbestos

Pinchin conducted an inspection for the presence of friable and non-friable asbestos-containing materials

(ACM). A friable material is a material that when dry can be crumbled, pulverized or powdered by hand

pressure.

Page 31: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

The City of Toronto Pinchin File: 113698.002

Methodology Appendix III

© 2017 Pinchin Ltd. Page 2 of 4

Pinchin collected samples at a rate that is in compliance with Table 1 of O.Reg. 278/05. A separate set of

samples was collected of each of homogenous material sampled. A homogenous material is defined by

the US EPA1 as material that is uniform in texture and appearance, was installed at one time, and is

unlikely to consist of more than one type or formulation of material. The homogeneous materials are

determined by visual examination, available information on the phases of the construction and prior

renovations.

The following materials were sampled:

All friable materials historically known to contain asbestos, regardless of year of

installation, not identified in previous reports;

Friable materials previously sampled in insufficient quantity to conclude the materials are

non-asbestos, in accordance with the requirements of O.Reg. 278/05;

Friable materials previously reported to contain less than 1% asbestos, if sampled prior to

the Ministry of Labour defining an asbestos-containing material as a material containing

contains 0.5 percent or more asbestos by weight;

Non-friable acoustic ceiling tiles;

Non-friable vinyl floor tiles and mastic.

The following materials were not sampled:

Materials previously identified in previous reports provided as asbestos-containing;

Materials previously confirmed to be non-asbestos in accordance with O.Reg. 278/05;

Unless damaged the following materials were not sampled: plaster, drywall joint

compound, mastic, window caulking, roofing materials, vinyl sheet flooring. Materials not

sampled are assumed to contain asbestos.

Materials where sampling poses an inherent, imminent danger to the Assessor such as

high voltage wiring, materials present at heights greater than 12 feet, or those in confined

spaces. These materials are assumed to be asbestos-containing.

In some cases, manufactured products such as asbestos cement pipe are visually identified without

sample confirmation.

1 Environmental Protection Agency

Page 32: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

The City of Toronto Pinchin File: 113698.002

Methodology Appendix III

© 2017 Pinchin Ltd. Page 3 of 4

Pinchin submits the bulk samples to a NVLAP2 accredited laboratory for analysis. The analysis is

performed in accordance with Test Method EPA/600/R-93/116: Method for the Determination of Asbestos

in Bulk Building Materials, July 1993.

The asbestos analysis is completed using a stop positive approach. Only one result of greater than the

regulated criteria (0.5%) is required to determine that a material is asbestos-containing, but all samples

must be analyzed to conclusively determine that a material is non-asbestos. The laboratory stops

analyzing samples from a homogeneous material once a result greater than the regulated criteria is

detected in any of the samples of that material. All samples of a homogeneous material are analyzed if no

asbestos is detected. In some cases, all samples are analyzed in the sample set regardless of result.

Where building materials are described in the report as non-asbestos, or described as containing no

asbestos, this is subject to the limitations of the analytical method used, and should be understood to

mean no asbestos was detected.

Asbestos materials are evaluated in order to make recommendations regarding remedial work. The

priority for remedial action is based on several factors:

friability (friable or non-friable).

condition (good, fair, poor, debris, based on definitions in the SOP).

accessibility (ranking from accessible to all building users to inaccessible).

visibility (whether the material is obscured by other building components).

efficiency of the work (for example, if damaged ACM is being removed in an area, it may

be most practical to remove all ACM in the area even if it is in good condition).

This includes friability, condition and efficiency and practicality of the work.

1.3 Lead

Pinchin collected samples of damaged paint not identified in a previous report. Drawings included show

sample locations.

Analysis for lead in paints or surface coatings is performed in accordance with EPA Method No.

3050B/Method No. 7420; flame atomic absorption at an accredited laboratory.

For this report, all paints containing lead at a concentration 0.1% or greater are discussed. Paint was

evaluated for condition.

Lead building products (e.g. batteries, lead sheeting, flashing) are identified by visual observation only.

2 National Voluntary Laboratory Accreditation Program

Page 33: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

Designated Substances Survey Report July 20, 2017

The City of Toronto Pinchin File: 113698.002

Methodology Appendix III

© 2017 Pinchin Ltd. Page 4 of 4

1.4 Silica

Pinchin identifies building materials suspected of containing crystalline silica (e.g. concrete, cement, tile,

brick, masonry, mortar) by knowledge of current and historic applications and visual inspection only.

Pinchin does not perform sampling of these materials for laboratory analysis of crystalline silica content.

1.5 Mercury

Building materials/products/equipment (e.g. thermostats, barometers, pressure gauges, light tubes),

suspected to contain mercury were identified by visual inspection only. Dismantling of equipment

suspected of containing mercury was not performed. Sampling of these materials for laboratory analysis

of mercury content was not performed.

Mercury spills or damaged mercury-containing equipment was recorded where observed.

1.6 Polychlorinated Biphenyls

Pinchin determines the potential for light ballast and wet transformers to contain PCBs based on the age

of the building, a review of maintenance records and examination of labels or nameplates on equipment,

where present and accessible. The information is compared to known ban dates of PCBs and

Environment Canada publications.

Dry type transformers are assumed to be free of dielectric fluids and hence non-PCB.

Pinchin records spills or leakage of suspect PCB-containing fluids where observed.

Fluids (mineral oil, hydraulic or Askaral) in transformers or other equipment are not sampled for PCB

content.

Non-liquid forms of PCBs (i.e. sealants or caulking) are not sampled for PCB content.

1.7 Visible Mould

Pinchin identifies the presence of mould if visibly present in a significant quantity on exposed building

surfaces. If any mould growth is concealed within wall cavities it is not addressed in this survey.

Page 34: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX IV

Survey Form

Page 35: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

0‐00 Building Exterior Roof Roofing Material Asbestos Not Sampled Assumed ACM 5000 ft² Good

0‐00 Building Exterior Windows Window Caulking Asbestos Not Sampled Assumed ACM 100 ft² Good

0‐00 Building Exterior Walls Concrete N/A N/A N/A N/A N/A

E1 Elevator Pit N/A N/A N/A N/A N/A N/A N/A *No access to room

B‐01 Housing Office Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

B‐01 Housing Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐01 Housing Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐01 Housing Office Ceiling  Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

B‐01 Housing Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

Located above ceiling tiles                                                    2012 Pinchin DSS Assessment;                                         2013 ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐01 Housing Office Pipes Fibreglass N/A N/A N/A N/A N/A

B‐01 Housing Office Ducts Not Insulated N/A N/A N/A N/A N/A

B‐01 Housing Office Mechanical N/A N/A N/A N/A N/A N/A

B‐02 Lounge Floor Vinyl Floor Tile Asbestos 2014‐A0002 A‐C None Detected N/A N/A12 x 12 Grey with Grey Fleck and mastic;                                     2014 Pinchin DSS Reassessment

B‐02 Lounge Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐02 Lounge Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐02 Lounge Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

B‐02 Lounge Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

Located above ceiling tiles                                                    2012Pinchin DSS Assessment;                                         2013 ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐02 Lounge Pipes Fibreglass N/A N/A N/A N/A N/A

B‐02 Lounge Ducts Not Insulated N/A N/A N/A N/A N/A

B‐02 Lounge Mechanical N/A N/A N/A N/A N/A N/A

B‐03 Program Office Floor Vinyl Floor Tile Asbestos 2014‐A0002 A‐C None Detected N/A N/A12 x 12 Grey with Grey Fleck and mastic;                                     2014 Pinchin DSS Reassessment

B‐03 Program Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

674 Dundas Street West, Toronto 1 of 31

Page 36: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐03 Program Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐03 Program Office Ceiling  Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

B‐03 Program Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

Located above ceiling tiles                                                    2012Pinchin DSS Assessment;                                         2013 ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐03 Program Office Pipes Fibreglass N/A N/A N/A N/A N/A

B‐03 Program Office Ducts Not Insulated N/A N/A N/A N/A N/A

B‐03 Program Office Mechanical N/A N/A N/A N/A N/A N/A

B‐04 Corridor Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Grey with Grey Fleck and mastic;                                     2014 Pinchin DSS Reassessment

B‐04 Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐04 Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐04 Corridor Ceiling  Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

B‐04 Corridor Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

Located above ceiling tiles                                                    2012Pinchin DSS Assessment;                                         2013 ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐04 Corridor Pipes Fibreglass N/A N/A N/A N/A N/A

B‐04 Corridor Ducts Not Insulated N/A N/A N/A N/A N/A

B‐04 Corridor Mechanical N/A N/A N/A N/A N/A N/A

B‐05 Elevator  Room Floor Concrete N/A N/A N/A N/A N/A

B‐05 Elevator  Room Wall Masonry N/A N/A N/A N/A N/A

B‐05 Elevator  Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐05 Elevator  Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

B‐05 Elevator  Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

Located above ceiling tiles                                                    2012Pinchin DSS Assessment;                                         2013 ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐05 Elevator  Room Pipes N/A N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 2 of 31

Page 37: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐05 Elevator  Room Ducts Not Insulated N/A N/A N/A N/A N/A

B‐05 Elevator  Room Mechanical N/A N/A N/A N/A N/A N/A

B‐06 Storage Room Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

B‐06 Storage Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐06 Storage Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐06 Storage Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

B‐06 Storage Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      None Detected N/A N/A

Located above ceiling tiles                                                    2012Pinchin DSS Assessment;                                         2013 ECHO

B‐06 Storage Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐06 Storage Room Ducts Not Insulated N/A N/A N/A N/A N/A

B‐06 Storage Room Mechanical N/A N/A N/A N/A N/A N/A

B‐07a Washrooms Floor Ceramic N/A N/A N/A N/A N/A

B‐07a Washrooms Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐07a Washrooms Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐07a Washrooms Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐07a Washrooms Pipes Fibreglass N/A N/A N/A N/A N/A

B‐07a Washrooms Ducts N/A N/A N/A N/A N/A N/A

B‐07a Washrooms Mechanical N/A N/A N/A N/A N/A N/A

B‐07b Shower Floor Ceramic N/A N/A N/A N/A N/A

B‐07b Shower Walls  Ceramic N/A N/A N/A N/A N/A

B‐07b Shower Ceiling  Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐07b Shower Pipes Not Insulated N/A N/A N/A N/A N/A

B‐07b Shower Ducts N/A N/A N/A N/A N/A N/A

B‐07b Shower Mechanical N/A N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 3 of 31

Page 38: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐08 Janitor's Closet Floor Ceramic N/A N/A N/A N/A N/A

B‐08 Janitor's Closet Wall Masonry N/A N/A N/A N/A N/A

B‐08 Janitor's Closet Wall Yellow Paint  Lead 2012‐Pb01 0.14% N/A N/A

B‐08 Janitor's Closet Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐08 Janitor's Closet Pipes Not Insulated N/A N/A N/A N/A N/A

B‐08 Janitor's Closet Ducts N/A N/A N/A N/A N/A N/A

B‐08 Janitor's Closet Mechanical N/A N/A N/A N/A N/A N/A

B‐09 Laundry Room Floor Ceramic N/A N/A N/A N/A N/A

B‐09 Laundry Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐09 Laundry Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐09 Laundry Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐09 Laundry Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐09 Laundry Room Ducts Not Insulated N/A N/A N/A N/A N/A

B‐09 Laundry Room Mechanical N/A N/A N/A N/A N/A N/A

B‐10 Storage Room Floor Ceramic N/A N/A N/A N/A N/A

B‐10 Storage Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐10 Storage Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐10 Storage Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐10 Storage Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐10 Storage Room Ducts N/A N/A N/A N/A N/A N/A

B‐10 Storage Room Mechanical N/A N/A N/A N/A N/A N/A

B‐11 Storage Room Floor Ceramic N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 4 of 31

Page 39: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐11 Storage Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐11 Storage Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐11 Storage Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐11 Storage Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐11 Storage Room Ducts Not Insulated N/A N/A N/A N/A N/A

B‐11 Storage Room Mechanical N/A N/A N/A N/A N/A N/A

B‐12Doctor's Office/ Exam Room

Floor Concrete N/A N/A N/A N/A N/A

B‐12Doctor's Office/ Exam Room

Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐12Doctor's Office/ Exam Room

Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐12Doctor's Office/ Exam Room

Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐12Doctor's Office/ Exam Room

Pipes N/A N/A N/A N/A N/A N/A

B‐12Doctor's Office/ Exam Room

Ducts N/A N/A N/A N/A N/A N/A

B‐12Doctor's Office/ Exam Room

Mechanical N/A N/A N/A N/A N/A N/A

B‐13 Electrical Room Floor Concrete N/A N/A N/A N/A N/A12x12 Green vinyl floor tiles Non‐Asbestos (2014‐A0001A‐C), have been removed prior to 2015 Reassessment

B‐13 Electrical Room Walls  Masonry N/A N/A N/A N/A N/A

B‐13 Electrical Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐13 Electrical Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐13 Electrical Room Ducts N/A N/A N/A N/A N/A N/A

B‐13 Electrical Room Mechanical Not Insulated N/A N/A N/A N/A N/A

B‐14 Lounge Floor Concrete N/A N/A N/A N/A N/A

B‐14 Lounge Floor Masonry N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 5 of 31

Page 40: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐14 Lounge Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐14 Lounge Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐14 Lounge Pipes Fibreglass N/A N/A N/A N/A N/A

B‐14 Lounge Ducts N/A N/A N/A N/A N/A N/A

B‐14 Lounge Mechanical N/A N/A N/A N/A N/A N/A

B‐15 Office Floor Concrete N/A N/A N/A N/A N/A

B‐15 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐15 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐15 Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐15 Office Pipes Fibreglass N/A N/A N/A N/A N/A

B‐15 Office Ducts N/A N/A N/A N/A N/A N/A

B‐15 Office Mechanical N/A N/A N/A N/A N/A N/A

B‐16 Kitchen Storage Floor Concrete N/A N/A N/A N/A N/A

B‐16 Kitchen Storage Walls  Masonry N/A N/A N/A N/A N/A

B‐16 Kitchen Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐16 Kitchen Storage Pipes Fibreglass N/A N/A N/A N/A N/A

B‐16 Kitchen Storage Ducts N/A N/A N/A N/A N/A N/A

B‐16 Kitchen Storage Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

B‐17 Men's Changeroom Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

B‐17 Men's Changeroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐17 Men's Changeroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 6 of 31

Page 41: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐17 Men's Changeroom Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐17 Men's Changeroom Pipes Parging Cement  AsbestosVisually Similar to 2014 A0005 

A‐CNone Detected N/A N/A

B‐17 Men's Changeroom Pipes Fibreglass N/A N/A N/A N/A N/A

B‐17 Men's Changeroom Ducts N/A N/A N/A N/A N/A N/A

B‐17 Men's Changeroom Mechanical N/A N/A N/A N/A N/A N/A

B‐18 Women's Changeroom Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

B‐18 Women's Changeroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐18 Women's Changeroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐18 Women's Changeroom Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐18 Women's Changeroom Pipes Fibreglass N/A N/A N/A N/A N/A

B‐18 Women's Changeroom Ducts N/A N/A N/A N/A N/A N/A

B‐18 Women's Changeroom Mechanical N/A N/A N/A N/A N/A N/A

B‐19 Washroom Entrance Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

B‐19 Washroom Entrance Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐19 Washroom Entrance Wall Masonry N/A N/A N/A N/A N/A

B‐19 Washroom Entrance Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐19 Washroom Entrance Ceiling Acoustic Ceiling Tile Asbestos 2014‐A0006 A‐C None Detected N/A N/A2 x 4 Lay‐in Small and Large Pinhole Pattern;                       2014 Pinchin DSS Reassessment 

B‐19 Washroom Entrance Pipes Not Insulated N/A N/A N/A N/A N/A

B‐19 Washroom Entrance Ducts Not Insulated N/A N/A N/A N/A N/A

B‐19 Washroom Entrance Mechanical N/A N/A N/A N/A N/A N/A

B‐20 Corridor Floor Concrete N/A N/A N/A N/A N/A 12x12 Green VFT (2014-A0001A-C) removed before 2015 reassessment

B‐20 Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐20 Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 7 of 31

Page 42: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐20 Corridor Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐20 Corridor Pipes Parging Cement  AsbestosVisually Similar to 2014 A0005 

A‐CNone Detected N/A N/A

B‐20 Corridor Pipes Fibreglass N/A N/A N/A N/A N/A

B‐20 Corridor Ducts N/A N/A N/A N/A N/A N/A

B‐20 Corridor Mechanical N/A N/A N/A N/A N/A N/A

B‐21 Storage/Crawlspace Floor Concrete N/A N/A N/A N/A N/A

B‐21 Storage/Crawlspace Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐21 Storage/Crawlspace Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐21 Storage/Crawlspace Pipes N/A N/A N/A N/A N/A N/A

B‐21 Storage/Crawlspace Ducts N/A N/A N/A N/A N/A N/A

B‐21 Storage/Crawlspace Mechanical N/A N/A N/A N/A N/A N/A

B‐22 Washroom Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

B‐22 Washroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐22 Washroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐22 Washroom Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐22 Washroom Pipes Fibreglass N/A N/A N/A N/A N/A

B‐22 Washroom Ducts N/A N/A N/A N/A N/A N/A

B‐22 Washroom Mechanical N/A N/A N/A N/A N/A N/A

B‐23 Kitchen Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

B‐23 Kitchen Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐23 Kitchen Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐23 Kitchen Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

674 Dundas Street West, Toronto 8 of 31

Page 43: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐23 Kitchen Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0002A‐C None Detected N/A N/A 2 x 4 Lay‐in Widthwise Fissure and Pinhole

B‐23 Kitchen Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

N/A N/A N/A

Located above ceiling tiles                                                    2012Pinchin DSS Assessment;                                         2013 ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐23 Kitchen Pipes Fibreglass N/A N/A N/A N/A N/A

B‐23 Kitchen Ducts N/A N/A N/A N/A N/A N/A

B‐23 Kitchen Mechanical N/A N/A N/A N/A N/A N/A

B‐24 Sprinkler Room Floor Concrete N/A N/A N/A N/A N/A

B‐24 Sprinkler Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐24 Sprinkler Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐24 Sprinkler Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐24 Sprinkler Room Ducts N/A N/A N/A N/A N/A N/A

B‐24 Sprinkler Room Mechanical Not Insulated N/A N/A N/A N/A N/A

B‐25 Electrical Room Floor Concrete N/A N/A N/A N/A N/A

B‐25 Electrical Room Wall Brick N/A N/A N/A N/A N/A

B‐25 Electrical Room Ceiling Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐25 Electrical Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐25 Electrical Room Ducts N/A N/A N/A N/A N/A N/A

B‐25 Electrical Room Mechanical N/A N/A N/A N/A N/A N/A

B‐26 Storage Room Floor Concrete N/A N/A N/A N/A N/A

B‐26 Storage Room Wall Masonry N/A N/A N/A N/A N/A

B‐26 Storage Room Ceiling Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐26 Storage Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐26 Storage Room Pipes PVC N/A N/A N/A N/A N/A

B‐26 Storage Room Ducts N/A N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 9 of 31

Page 44: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

B‐26 Storage Room Mechanical N/A N/A N/A N/A N/A N/A

B‐27 Storage Room Floor Concrete N/A N/A N/A N/A N/A

B‐27 Storage Room Wall Masonry N/A N/A N/A N/A N/A

B‐27 Storage Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;                                         2013ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐27 Storage Room Pipes Parging Cement  Asbestos 2014‐A0005 A‐C None Detected N/A N/A

B‐27 Storage Room Pipes Fibreglass N/A N/A N/A N/A N/A

B‐27 Storage Room Ducts N/A N/A N/A N/A N/A N/A

B‐27 Storage Room Mechanical N/A N/A N/A N/A N/A N/A

B‐28 Rampway / Corridor Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

B‐28 Rampway / Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

B‐28 Rampway / Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

B‐28 Rampway / Corridor Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;                                         2013ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

B‐28 Rampway / Corridor Pipes Fibreglass N/A N/A N/A N/A N/A

B‐28 Rampway / Corridor Ducts N/A N/A N/A N/A N/A N/A

B‐28 Rampway / Corridor Mechanical N/A N/A N/A N/A N/A N/A

1‐01 Office Floor Vinyl Sheet Flooring Asbestos 2015‐A0006A‐C None Detected N/A N/A Beige/Tan/White/Blue Lines 

1‐01 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐01 Office Wall Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐01 Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐01 Office Pipes Not Insulated N/A N/A N/A N/A N/A

1‐01 Office Ducts N/A N/A N/A N/A N/A N/A NAC

1‐01 Office Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐02 Office Floor Vinyl Sheet Flooring Asbestos 2015‐A0006A‐C None Detected N/A N/A Beige/Tan/White/Blue Lines 

674 Dundas Street West, Toronto 10 of 31

Page 45: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐02 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐02 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐02 Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐02 Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0002A‐C None Detected N/A N/A 2 x 4 Lay‐in Widthwise Fissure and Pinhole

1‐02 Office Pipes Not Insulated N/A N/A N/A N/A N/A

1‐02 Office Ducts N/A N/A N/A N/A N/A N/A NAC

1‐02 Office Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐03 Office Floor Vinyl Sheet Flooring Asbestos 2015‐A0006A‐C None Detected N/A N/A Beige/Tan/White/Blue Lines 

1‐03 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐03 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐03 Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐03 Office Pipes Not Insulated N/A N/A N/A N/A N/A

1‐03 Office Ducts N/A N/A N/A N/A N/A N/A NAC

1‐03 Office Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐04 Reception Floor Vinyl Sheet Flooring Asbestos 2015‐A0006A‐C None Detected N/A N/A Beige/Tan/White/Blue Lines 

1‐04 Reception Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐04 Reception Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐04 Reception Wall Beige Paint Lead 2012‐Pb03 <0.009 N/A N/A

1‐04 Reception Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐04 Reception Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0002A‐C None Detected N/A N/A 2 x 4 Lay‐in Widthwise Fissure and Pinhole

1‐04 Reception Pipes Not Insulated N/A N/A N/A N/A N/A

1‐04 Reception Ducts N/A N/A N/A N/A N/A N/A NAC

1‐04 Reception Mechanical N/A N/A N/A N/A N/A N/A NAC

674 Dundas Street West, Toronto 11 of 31

Page 46: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐05 Dining Room Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

1‐05 Dining Room Floor Vinyl Floor Tile Asbestos 2015‐A0008A‐C None Detected N/A N/A 12"x12" yellow mottled and mastic

1‐05 Dining Room Floor Vinyl Floor Tile Asbestos 2015‐A0009A‐C None Detected N/A N/A 12"x12" orange mottled and mastic

1‐05 Dining Room Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark Blue mottled and mastic

1‐05 Dining Room Floor Vinyl Sheet Flooring Asbestos 2015‐A0005A‐C None Detected N/A N/A VSF orange (located underneath vinyl floor tiles)

1‐05 Dining Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐05 Dining Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐05 Dining Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐05 Dining Room Ceiling Texture Finish Asbestos  2016‐A0001A‐C None Detected N/A N/A 2016 Pinchin Reassessment

1‐05 Dining Room Pipes Not Insulated N/A N/A N/A N/A N/A

1‐05 Dining Room Ducts Not Insulated N/A N/A N/A N/A N/A

1‐05 Dining Room Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐06 Dishwashing Room Floor Vinyl Sheet Flooring Asbestos 2015‐A0003A‐C None Detected N/A N/A Grey with blue flecks

1‐06 Dishwashing Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐06 Dishwashing Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐06 Dishwashing Room Ceiling Drywall N/A N/A N/A N/A N/A Drywall panel  ceiling tiles for fire code

1‐06 Dishwashing Room Pipes Not Insulated N/A N/A N/A N/A N/A

1‐06 Dishwashing Room Ducts N/A N/A N/A N/A N/A N/A NAC

1‐06 Dishwashing Room Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐07 Office Floor Vinyl Sheet Flooring Asbestos 2015‐A0003A‐C None Detected N/A N/A Grey with blue flecks

1‐07 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐07 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐07 Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

674 Dundas Street West, Toronto 12 of 31

Page 47: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐07 Office Pipes Not Insulated N/A N/A N/A N/A N/A

1‐07 Office Ducts N/A N/A N/A N/A N/A N/A NAC

1‐07 Office Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐08 Servery Floor Vinyl  Sheet Flooring Asbestos 2015‐A0004A‐C None Detected N/A N/A Grey

1‐08 Servery Floor Vinyl Sheet Flooring Asbestos 2015‐A0005A‐C None Detected N/A N/AOrange  (located  underneath newer vinyl floor tiles and vinyl sheet flooring)

1‐08 Servery Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐08 Servery Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐08 Servery Ceiling Drywall Panels N/A N/A N/A N/A N/A

1‐08 Servery Pipes N/A N/A N/A N/A N/A N/A NAC

1‐08 Servery Ducts N/A N/A N/A N/A N/A N/A NAC

1‐08 Servery Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐09 Dry Goods Storage Room Floor Vinyl Floor Tile Asbestos 2014‐A0002 A‐C None Detected N/A N/A12 x 12 Grey with Grey Fleck and mastic;                                     2014 Pinchin DSS Reassessment

1‐09 Dry Goods Storage Room Wall Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;                                         2013ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

1‐09 Dry Goods Storage Room Ceiling N/A N/A N/A N/A N/A N/A Concrete Deck

1‐09 Dry Goods Storage Room Pipes Fibreglass N/A N/A N/A N/A N/A

1‐09 Dry Goods Storage Room Ducts N/A N/A N/A N/A N/A N/A

1‐09 Dry Goods Storage Room Mechanical N/A N/A N/A N/A N/A N/A

1‐10 Freezer Floor Metal N/A N/A N/A N/A N/A

1‐10 Freezer Wall Metal N/A N/A N/A N/A N/A

1‐10 Freezer Ceiling Metal N/A N/A N/A N/A N/A

1‐10 Freezer Pipes N/A N/A N/A N/A N/A N/A

1‐10 Freezer Ducts N/A N/A N/A N/A N/A N/A

1‐10 Freezer Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

1‐11 Wash Station Floor Vinyl Floor Tile Asbestos 2014‐A0002 A‐C None Detected N/A N/A12 x 12 Grey with Grey Fleck and mastic;                                     2014 Pinchin DSS Reassessment

674 Dundas Street West, Toronto 13 of 31

Page 48: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐11 Wash Station Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐11 Wash Station Wall Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;                                         2013ECHO Reassessment Survey;                                           2014 Pichin DSS Reassessment 

1‐11 Wash Station Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐11 Wash Station Pipes Not Insulated N/A N/A N/A N/A N/A

1‐11 Wash Station Ducts N/A N/A N/A N/A N/A N/A

1‐11 Wash Station Mechanical N/A N/A N/A N/A N/A N/A

1‐12 Kitchen Floor Terrazzo N/A N/A N/A N/A N/A

1‐12 Kitchen Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐12 Kitchen Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐12 Kitchen Ceiling Drywall Panels N/A N/A N/A N/A N/A

1‐12 Kitchen Pipes Not Insulated N/A N/A N/A N/A N/A

1‐12 Kitchen Ducts N/A N/A N/A N/A N/A N/A

1‐12 Kitchen Mechanical N/A N/A N/A N/A N/A N/A

1‐13 Office/Storage Floor Terrazzo N/A N/A N/A N/A N/A

1‐13 Office/Storage Wall Plaster Asbestos 2014‐A0002 A‐C None Detected N/A N/A

1‐13 Office/Storage Ceiling Limited Access Limited Access/View due to Stored Items and Ductwork

1‐13 Office/Storage Pipes Not Insulated N/A N/A N/A N/A N/A

1‐13 Office/Storage Ducts Not Insulated N/A N/A N/A N/A N/A

1‐13 Office/Storage Mechanical N/A N/A N/A N/A N/A N/A

1‐14 Corridor Floor Ceramic N/A N/A N/A N/A N/A

1‐14 Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐14 Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐14 Corridor Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

674 Dundas Street West, Toronto 14 of 31

Page 49: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐14 Corridor Pipes N/A N/A N/A N/A N/A N/A NAC

1‐14 Corridor Ducts N/A N/A N/A N/A N/A N/A NAC

1‐14 Corridor Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐15 Overflow Room Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

1‐15 Overflow Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐15 Overflow Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐15 Overflow Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐15 Overflow Room Pipes N/A N/A N/A N/A N/A N/A

1‐15 Overflow Room Ducts N/A N/A N/A N/A N/A N/A

1‐15 Overflow Room Mechanical N/A N/A N/A N/A N/A N/A

1‐16 Intake Office Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

1‐16 Intake Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐16 Intake Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐16 Intake Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐16 Intake Office Pipes Fibreglass N/A N/A N/A N/A N/A

1‐16 Intake Office Ducts Not Insulated N/A N/A N/A N/A N/A

1‐16 Intake Office Mechanical N/A N/A N/A N/A N/A N/A

1‐17 Manager's Office Floor Vinyl Floor Tile Asbestos  2015‐A0011 A‐C None Detected N/A N/A 12 x 12 Cream with Beige Fleck and mastic

1‐17 Manager's Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐17 Manager's Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐17 Manager's Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐17 Manager's Office Pipes Not Insulated N/A N/A N/A N/A N/A

1‐17 Manager's Office Ducts Not Insulated N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 15 of 31

Page 50: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐17 Manager's Office Mechanical N/A N/A N/A N/A N/A N/A

1‐18 Office Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

1‐18 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐18 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐18 Office Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐18 Office Pipes Fibreglass N/A N/A N/A N/A N/A

1‐18 Office Ducts Not Insulated N/A N/A N/A N/A N/A

1‐18 Office Mechanical N/A N/A N/A N/A N/A N/A

1‐19 Copy Room Floor Ceramic N/A N/A N/A N/A N/A

1‐19 Copy Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐19 Copy Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐19 Copy Room Ceiling Acoustic Ceiling Tile Asbestos 2014‐A0006 A‐C None Detected N/A N/A2 x 4 Lay‐in Small and Large Pinhole Pattern;                       2014 Pinchin DSS Reassessment 

1‐19 Copy Room Pipes Not Insulated N/A N/A N/A N/A N/A

1‐19 Copy Room Ducts Not Insulated N/A N/A N/A N/A N/A

1‐19 Copy Room Mechanical N/A N/A N/A N/A N/A N/A

1‐20 Washroom Floor Ceramic N/A N/A N/A N/A N/A

1‐20 Washroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐20 Washroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐20 Washroom Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐20 Washroom Pipes Not Insulated N/A N/A N/A N/A N/A

1‐20 Washroom Ducts Not Insulated N/A N/A N/A N/A N/A

1‐20 Washroom Mechanical N/A N/A N/A N/A N/A N/A

1‐21 Laundry Room Floor Ceramic N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 16 of 31

Page 51: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐21 Laundry Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐21 Laundry Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐21 Laundry Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in Fissure and Pinhole Pattern

1‐21 Laundry Room Pipes Not Insulated N/A N/A N/A N/A N/A

1‐21 Laundry Room Ducts Not Insulated N/A N/A N/A N/A N/A

1‐21 Laundry Room Mechanical N/A N/A N/A N/A N/A N/A

1‐22a Washroom Floor Ceramic N/A N/A N/A N/A N/A

1‐22a Washroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐22a Washroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐22a Washroom Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐22a Washroom Pipes Not Insulated N/A N/A N/A N/A N/A

1‐22a Washroom Ducts Not Insulated N/A N/A N/A N/A N/A

1‐22a Washroom Mechanical N/A N/A N/A N/A N/A N/A

1‐22b Shower Wall Ceramic N/A N/A N/A N/A N/A

1‐22b Shower Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

1‐22b Shower Pipes N/A N/A N/A N/A N/A N/A NAC

1‐22b Shower Ducts N/A N/A N/A N/A N/A N/A NAC

1‐22b Shower Mechanical N/A N/A N/A N/A N/A N/A NAC

1‐23 Janitor's Closet Floor Ceramic Tiles N/A N/A N/A N/A N/A

1‐23 Janitor's Closet Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

1‐23 Janitor's Closet Wall Drywall Joint Compound Asbestos 2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐23 Janitor's Closet Wall Yellow Paint  Lead 2012‐Pb02 <0.009% N/A N/A

674 Dundas Street West, Toronto 17 of 31

Page 52: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

1‐23 Janitor's Closet Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

1‐23 Janitor's Closet Pipes Fibreglass N/A N/A N/A N/A N/A

1‐23 Janitor's Closet Ducts N/A N/A N/A N/A N/A N/A

1‐23 Janitor's Closet Mechanical N/A N/A N/A N/A N/A N/A

2‐01 Housing Office Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark Blue mottled and mastic

2‐01 Housing Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐01 Housing Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐01 Housing Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐01 Housing Office Pipes Not Insulated N/A N/A N/A N/A N/A

2‐01 Housing Office Ducts Not Insulated N/A N/A N/A N/A N/A

2‐01 Housing Office Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐02 Housing Outreach Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

2‐02 Housing Outreach Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐02 Housing Outreach Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐02 Housing Outreach Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐02 Housing Outreach Pipes N/A N/A N/A N/A N/A N/A

2‐02 Housing Outreach Ducts N/A N/A N/A N/A N/A N/A

2‐02 Housing Outreach Mechanical N/A N/A N/A N/A N/A N/A

2‐03 Washroom Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark Blue mottled and mastic

2‐03 Washroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐03 Washroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 18 of 31

Page 53: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

2‐03 Washroom Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐03 Washroom Pipes Not Insulated N/A N/A N/A N/A N/A

2‐03 Washroom Ducts N/A N/A N/A N/A N/A N/A

2‐03 Washroom Mechanical N/A N/A N/A N/A N/A N/A

2‐04 to       2‐11

Bedrooms Floor Vinyl Floor Tile Asbestos 2015‐A0012A‐C None Detected N/A N/A 12 x 12 Blue mottled and mastic

2‐04 to       2‐11

Bedrooms Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐04 to       2‐12

Bedrooms Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐04 to       2‐13

Bedrooms Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐04 to       2‐14

Bedrooms Pipes Fibreglass N/A N/A N/A N/A N/A

2‐04 to       2‐15

Bedrooms Ducts N/A N/A N/A N/A N/A N/A

2‐04 to       2‐16

Bedrooms Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐12 Storage Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

2‐12 Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐12 Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐12 Storage Pipes Not Insulated N/A N/A N/A N/A N/A

2‐12 Storage Ducts N/A N/A N/A N/A N/A N/A

2‐12 Storage Mechanical N/A N/A N/A N/A N/A N/A

2‐13 Electrical Room Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

2‐13 Electrical Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐13 Electrical Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐13 Electrical Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 19 of 31

Page 54: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

2‐13 Electrical Room Pipes Not Insulated N/A N/A N/A N/A N/A

2‐13 Electrical Room Ducts Not Insulated N/A N/A N/A N/A N/A

2‐13 Electrical Room Mechanical Not Insulated N/A N/A N/A N/A N/A

2‐13 Electrical Room Mechanical Transformer PCBs N/A None Detected N/A N/A Dry  Type Transformer

2‐14 Maintenance / Storage Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

2‐14 Maintenance / Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐14 Maintenance / Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐14 Maintenance / Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐14 Maintenance / Storage Pipes Fibreglass N/A N/A N/A N/A N/A

2‐14 Maintenance / Storage Ducts N/A N/A N/A N/A N/A N/A

2‐14 Maintenance / Storage Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐16 Laundry Room Floor Terrazzo N/A N/A N/A N/A N/A

2‐16 Laundry Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐16 Laundry Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐16 Laundry Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐16 Laundry Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in, Fissure and Pinhole Pattern

2‐16 Laundry Room Pipes Fibreglass N/A N/A N/A N/A N/A

2‐16 Laundry Room Ducts Not Insulated N/A N/A N/A N/A N/A

2‐16 Laundry Room Mechanical N/A N/A N/A N/A N/A N/A

2‐15/2‐17 Washrooms Floor Terrazzo N/A N/A N/A N/A N/A

2‐15/2‐17 Washrooms Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐15/2‐18 Washrooms Wall Drywall Joint Compound Lead  2016‐L0002 <0.006% N/A N/A

2‐15/2‐18 Washrooms Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 20 of 31

Page 55: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

2‐15/2‐19 Washrooms Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐15/2‐20 Washrooms Pipes N/A N/A N/A N/A N/A N/A

2‐15/2‐21 Washrooms Ducts N/A N/A N/A N/A N/A N/A

2‐15/2‐22 Washrooms Mechanical N/A N/A N/A N/A N/A N/A

2‐18 Janitor's Closet Floor Terrazzo N/A N/A N/A N/A N/A

2‐18 Janitor's Closet Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐18 Janitor's Closet Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐18 Janitor's Closet Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐18 Janitor's Closet Pipes Not Insulated N/A N/A N/A N/A N/A

2‐18 Janitor's Closet Ducts N/A N/A N/A N/A N/A N/A

2‐18 Janitor's Closet Mechanical N/A N/A N/A N/A N/A N/A

2‐19 Storage Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark blue mottled and mastic

2‐19 Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐19 Storage Wall Drywall Joint Compound Asbestos 2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐19 Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐19 Storage Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in, Fissure and Pinhole Pattern

2‐19 Storage Pipes Not Insulated N/A N/A N/A N/A N/A

2‐19 Storage Ducts N/A N/A N/A N/A N/A N/A

2‐19 Storage Mechanical N/A N/A N/A N/A N/A N/A

2‐20 Staff Room Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark blue mottled and mastic

2‐20 Staff Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐20 Staff Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 21 of 31

Page 56: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

2‐20 Staff Room Ceiling Drywall Joint Compound Asbestos 2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐20 Staff Room Wall Paint Lead 2016‐L0002 <0.006% N/A N/A blue paint

2‐20 Staff Room Pipes Fibreglass N/A N/A N/A N/A N/A

2‐20 Staff Room Ducts N/A N/A N/A N/A N/A N/A

2‐20 Staff Room Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐21 Balcony Floor Concrete N/A N/A N/A N/A N/A

2‐21 Balcony Wall Concrete N/A N/A N/A N/A N/A

2‐21 Balcony Ceiling Concrete N/A N/A N/A N/A N/A

2‐21 Balcony Pipes N/A N/A N/A N/A N/A N/A

2‐21 Balcony Ducts N/A N/A N/A N/A N/A N/A

2‐21 Balcony Mechanical N/A N/A N/A N/A N/A N/A

2‐22 Office Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark blue mottled and mastic

2‐22 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐22 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐22 Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐22 Office Pipes N/A N/A N/A N/A N/A N/A

2‐22 Office Ducts N/A N/A N/A N/A N/A N/A

2‐22 Office Mechanical N/A N/A N/A N/A N/A N/A

2‐23 Counsellor's Office Floor Vinyl Floor Tile Asbestos 2015‐A0012A‐C None Detected N/A N/A 12 x 12 Blue Mottled and mastic

2‐23 Counsellor's Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐23 Counsellor's Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      None Detected N/A N/A

2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;

2‐23 Counsellor's Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      None Detected N/A N/A

2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;

2‐23 Counsellor's Office Pipes Fibreglass N/A N/A N/A N/A N/A

2‐23 Counsellor's Office Ducts Not Insulated N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 22 of 31

Page 57: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

2‐23 Counsellor's Office Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐24 Office Floor Vinyl Floor Tile Asbestos 2015‐A0012A‐C None Detected N/A N/A 12 x 12 Blue Mottled and mastic

2‐24 Office Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐24 Office Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

2‐24 Office Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A

2‐24 Office Pipes Fibreglass N/A N/A N/A N/A N/A

2‐24 Office Ducts Not Insulated N/A N/A N/A N/A N/A

2‐24 Office Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐25 Meeting Room Floor Vinyl Sheet Flooring Asbestos 2015‐A0007A‐C None Detected N/A N/A Orange/Brown

2‐25 Meeting Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐25 Meeting Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐25 Meeting Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐25 Meeting Room Pipes Fibreglass N/A N/A N/A N/A N/A

2‐25 Meeting Room Ducts Not Insulated N/A N/A N/A N/A N/A

2‐25 Meeting Room Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

2‐26 Corridor Floor Vinyl Floor Tile Asbestos 2015‐A0010A‐C None Detected N/A N/A 12 x 12 Dark blue mottled and mastic

2‐26 Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

2‐26 Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐26 Corridor Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

2‐26 Corridor Pipes Not Insulated N/A N/A N/A N/A N/A

2‐26 Corridor Ducts N/A N/A N/A N/A N/A N/A NAC

2‐26 Corridor Mechanical N/A N/A N/A N/A N/A N/A NAC

674 Dundas Street West, Toronto 23 of 31

Page 58: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

3‐01 to       3‐14

Bedrooms Floor Vinyl Floor Tile Asbestos 2015‐A0012A‐C None Detected N/A N/A 12 x 12 Blue Mottled and mastic

3‐01 to       3‐14

Bedrooms Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐01 to       3‐15

Bedrooms Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐01 to       3‐16

Bedrooms Ceiling Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐01 to       3‐17

Bedrooms Pipes Fibreglass N/A N/A N/A N/A N/A

3‐01 to       3‐18

Bedrooms Ducts N/A N/A N/A N/A N/A N/A

3‐01 to       3‐19

Bedrooms Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

3‐16 Staff Room Floor Vinyl Floor Tile Asbestos  2015‐A0015A‐C None Detected N/A N/A 12 x 12 Purple and mastic

3‐16 Staff Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐16 Staff Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐16 Staff Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐16 Staff Room Pipes Fibreglass N/A N/A N/A N/A N/A

3‐16 Staff Room Ducts N/A N/A N/A N/A N/A N/A

3‐16 Staff Room Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

3‐17 Medical Supplies Floor Vinyl Floor Tile Asbestos  2015‐A0015A‐C None Detected N/A N/A 12 x 12 Purple and mastic

3‐17 Medical Supplies Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐17 Medical Supplies Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐17 Medical Supplies Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐17 Medical Supplies Pipes Fibreglass N/A N/A N/A N/A N/A

3‐17 Medical Supplies Ducts N/A N/A N/A N/A N/A N/A

3‐17 Medical Supplies Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

3‐18 Storage Floor Vinyl Floor Tile Asbestos  2015‐A0013A‐C None Detected N/A N/A 12 x12 Grey with White  Streaks and mastic

674 Dundas Street West, Toronto 24 of 31

Page 59: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

3‐18 Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐18 Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐18 Storage Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0002A‐C None Detected N/A N/A 2 x 4 Lay‐in Widthwise Fissure and Pinhole

3‐18 Storage Pipes Not Insulated N/A N/A N/A N/A N/A

3‐18 Storage Ducts Not Insulated N/A N/A N/A N/A N/A

3‐18 Storage Mechanical N/A N/A N/A N/A N/A N/A

3‐19 Janitor's Closet Floor Terrazzo N/A N/A N/A N/A N/A

3‐19 Janitor's Closet Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐19 Janitor's Closet Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐19 Janitor's Closet Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐19 Janitor's Closet Pipes N/A N/A N/A N/A N/A N/A NAC

3‐19 Janitor's Closet Ducts N/A N/A N/A N/A N/A N/A NAC

3‐19 Janitor's Closet Mechanical N/A N/A N/A N/A N/A N/A NAC

3‐20 Washroom Floor Terrazzo N/A N/A N/A N/A N/A

3‐20 Washroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐20 Washroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐20 Washroom Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐20 Washroom Pipes N/A N/A N/A N/A N/A N/A NAC

3‐20 Washroom Ducts N/A N/A N/A N/A N/A N/A NAC

3‐20 Washroom Mechanical N/A N/A N/A N/A N/A N/A NAC

3‐21 Showers Floor Terrazzo N/A N/A N/A N/A N/A

3‐21 Showers Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 25 of 31

Page 60: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

3‐21 Showers Ceiling Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐21 Showers Pipes N/A N/A N/A N/A N/A N/A NAC

3‐21 Showers Ducts N/A N/A N/A N/A N/A N/A NAC

3‐21 Showers Mechanical N/A N/A N/A N/A N/A N/A NAC

3‐22 Electrical Room Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

3‐22 Electrical Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐22 Electrical Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐22 Electrical Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐22 Electrical Room Pipes Not Insulated N/A N/A N/A N/A N/A

3‐22 Electrical Room Ducts N/A N/A N/A N/A N/A N/A

3‐22 Electrical Room Mechanical N/A N/A N/A N/A N/A N/A

3‐23 Storage Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

3‐23 Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐23 Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐23 Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐23 Storage Pipes Not Insulated N/A N/A N/A N/A N/A

3‐23 Storage Ducts N/A N/A N/A N/A N/A N/A

3‐23 Storage Mechanical N/A N/A N/A N/A N/A N/A

3‐24 Corridor Floor Vinyl Floor Tile Asbestos  2015‐A0015A‐C None Detected N/A N/A 12 x 12 Purple and mastic

3‐24 Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐24 Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 26 of 31

Page 61: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

3‐24 Corridor Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐24 Corridor Pipes Not Insulated N/A N/A N/A N/A N/A

3‐24 Corridor Ducts N/A N/A N/A N/A N/A N/A

3‐24 Corridor Mechanical N/A N/A N/A N/A N/A N/A

3‐25 Maintenance / Storage Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

3‐25 Maintenance / Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

3‐25 Maintenance / Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐25 Maintenance / Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

3‐25 Maintenance / Storage Pipes Not Insulated N/A N/A N/A N/A N/A

3‐25 Maintenance / Storage Ducts N/A N/A N/A N/A N/A N/A

3‐25 Maintenance / Storage Mechanical N/A N/A N/A N/A N/A N/A

4‐01 to       4‐12

Bedrooms Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

4‐01 to       4‐12

Bedrooms Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐01 to       4‐13

Bedrooms Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐01 to       4‐14

Bedrooms Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐01 to       4‐15

Bedrooms Pipes Fibreglass N/A N/A N/A N/A N/A

4‐01 to       4‐16

Bedrooms Ducts N/A N/A N/A N/A N/A N/A

4‐01 to       4‐17

Bedrooms Mechanical Not Insulated N/A N/A N/A N/A N/A Fan Unit

4‐14 Staff Room Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

4‐14 Staff Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐14 Staff Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 27 of 31

Page 62: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

4‐14 Staff Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐14 Staff Room Pipes Not Insulated N/A N/A N/A N/A N/A

4‐14 Staff Room Ducts N/A N/A N/A N/A N/A N/A

4‐14 Staff Room Mechanical N/A N/A N/A N/A N/A N/A

4‐15 Lounge Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

4‐15 Lounge Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐15 Lounge Wall Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐15 Lounge Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐15 Lounge Pipes Not Insulated N/A N/A N/A N/A N/A

4‐15 Lounge Ducts N/A N/A N/A N/A N/A N/A

4‐15 Lounge Mechanical N/A N/A N/A N/A N/A N/A

4‐16 Linen Room Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

4‐16 Linen Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐16 Linen Room Wall Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐16 Linen Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐16 Linen Room Pipes Not Insulated N/A N/A N/A N/A N/A

4‐16 Linen Room Ducts N/A N/A N/A N/A N/A N/A

4‐16 Linen Room Mechanical N/A N/A N/A N/A N/A N/A

4‐17 Laundry Room Floor Terrazzo N/A N/A N/A N/A N/A

4‐17 Laundry Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐17 Laundry Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 28 of 31

Page 63: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

4‐17 Laundry Room Ceiling Drywall Joint Compound N/A2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐17 Laundry Room Ceiling Acoustic Ceiling Tile Asbestos 2015‐A0001A‐C None Detected N/A N/A 2 x 4 Lay‐in, Fissure and Pinhole Pattern

4‐17 Laundry Room Pipes Not Insulated N/A N/A N/A N/A N/A

4‐17 Laundry Room Ducts Not Insulated N/A N/A N/A N/A N/A

4‐17 Laundry Room Mechanical N/A N/A N/A N/A N/A N/A

4‐18 Storage Floor Terrazzo N/A N/A N/A N/A N/A

4‐18 Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐18 Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐18 Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐18 Storage Pipes Not Insulated N/A N/A N/A N/A N/A

4‐18 Storage Ducts N/A N/A N/A N/A N/A N/A

4‐18 Storage Mechanical N/A N/A N/A N/A N/A N/A

4‐19 Washroom Floor Terrazzo N/A N/A N/A N/A N/A

4‐19 Washroom Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐19 Washroom Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐19 Washroom Ceiling Drywall Joint Compound Asbestos 2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐19 Washroom Pipes N/A N/A N/A N/A N/A N/A NAC

4‐19 Washroom Ducts N/A N/A N/A N/A N/A N/A NAC

4‐19 Washroom Mechanical N/A N/A N/A N/A N/A N/A NAC

4‐20 Showers Floor Terrazzo N/A N/A N/A N/A N/A

4‐20 Showers Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐20 Showers Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 29 of 31

Page 64: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

4‐20 Showers Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐20 Showers Pipes N/A N/A N/A N/A N/A N/A NAC

4‐20 Showers Ducts N/A N/A N/A N/A N/A N/A NAC

4‐20 Showers Mechanical N/A N/A N/A N/A N/A N/A NAC

4‐21 Electrical Room Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

4‐21 Electrical Room Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐21 Electrical Room Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐21 Electrical Room Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐21 Electrical Room Pipes Not Insulated N/A N/A N/A N/A N/A

4‐21 Electrical Room Ducts N/A N/A N/A N/A N/A N/A

4‐21 Electrical Room Mechanical N/A N/A N/A N/A N/A N/A

4‐22 Storage Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

4‐22 Storage Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐22 Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐22 Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐22 Storage Pipes Not Insulated N/A N/A N/A N/A N/A

4‐22 Storage Ducts N/A N/A N/A N/A N/A N/A

4‐22 Storage Mechanical N/A N/A N/A N/A N/A N/A

4‐23 Maintenance / Storage Floor Vinyl Floor Tile Asbestos 2014‐A0004 A‐C None Detected N/A N/A12 x 12 Beige and mastic; 2014 Pinchin DSS Reassessment 

4‐23 Maintenance / Storage Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐23 Maintenance / Storage Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

674 Dundas Street West, Toronto 30 of 31

Page 65: FINAL Designated Substances Survey Report · Survey Report Women’s Residence 674 Dundas Street West, Toronto, Ontario Prepared for: The City of Toronto Facilities Management 55

APPENDIX V - Survey Form

Location Number Location Name Building

System Material ObservedPotential

Hazardous Material

Sample ID Analytical Result

Qua

ntity

Con

ditio

n

Notes / Recommended Actions

October 18, 2016

Notes

674 Dundas Street West

Women's Residence Pinchin Ltd - T. Stanisic

Date(s) of Current Survey:

Organization Completing Survey

Building Address

Building Name

4‐23 Maintenance / Storage Pipes Not Insulated N/A N/A N/A N/A N/A

4‐23 Maintenance / Storage Ducts N/A N/A N/A N/A N/A N/A

4‐23 Maintenance / Storage Mechanical N/A N/A N/A N/A N/A N/A

4‐24 Corridor Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

4‐24 Corridor Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

4‐24 Corridor Wall Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐24 Corridor Ceiling Drywall Joint Compound Asbestos2012‐A0002 A‐C;             

2013‐14375‐A17‐03 A‐C;      2014‐A0003 A‐C

None Detected N/A N/A2012 Pinchin DSS Assessment;2013 ECHO Reassessment Survey;2014 Pichin DSS Reassessment 

4‐24 Corridor Pipes Fibreglass N/A N/A N/A N/A N/A

4‐24 Corridor Ducts N/A N/A N/A N/A N/A N/A

4‐24 Corridor Mechanical N/A N/A N/A N/A N/A N/A

S1 Main Stairwell Floor Vinyl Floor Tile Asbestos 2014‐A0001 A‐C None Detected N/A N/A12 x 12 Green and mastic; 2014 Pichin DSS Reassessment 

S1 Main Stairwell Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

S1 Main Stairwell Wall Plaster Lead 2012‐Pb01 0.14% 4 sf Good

S1 Main Stairwell Wall Plaster Lead 2016‐L0001 0.10% 4sf Poor pink flaking paint 

S1 Main Stairwell Ceiling Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

S1 Main Stairwell Pipes N/A N/A N/A N/A N/A N/A

S1 Main Stairwell Ducts N/A N/A N/A N/A N/A N/A

S1 Main Stairwell Mechanical N/A N/A N/A N/A N/A N/A

S2 Stairwell Floor Concrete N/A N/A N/A N/A N/A

S2 Stairwell Wall Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

S2 Stairwell Ceiling Plaster Asbestos 2014‐A0008 A‐G None Detected N/A N/A

S2 Stairwell Pipes N/A N/A N/A N/A N/A N/A

S2 Stairwell Ducts N/A N/A N/A N/A N/A N/A

S2 Stairwell Mechanical N/A N/A N/A N/A N/A N/A

674 Dundas Street West, Toronto 31 of 31