Bulletin No. 2200.4 FILTER REMEDIATION 6739 S. Washington Ave., P.O. Box 469, Whittier, CA 90608 Fax: (562) 693-5257 e-mail: [email protected] Web Site: www.pfdiv.com FIELD SERVICES o Qualified personnel to inspect / troubleshoot existing filtration systems, perform pilot filter study, offer recommendations and a quotation for filter system remediation and recommissioning of filter system UNDERDRAIN REPLACEMENT o Inspect existing filter internals o Replace broken PVC underdrains / laterals with 316 L stainless steel wedgewire components MEDIA REPLACEMENT o Multimedia replacement loads to improve filter performance CONTROLS … VALVES … PRETREATMENT o Replace original control panel with updated microprocessor based design o Replace butterfly valves/actuators o Add pre- or post-treatment equipment including coagulant feed, oxidation/ disinfection equipment, water quality monitors/controls BACKWASH WATER RECLAIM SYSTEM o Reclaim up to 99% of total backwash volume o Reduce or eliminate backwash water discharge PILOT FILTERS o Onsite pilot filter systems (flow rates from 0.50 gpm to 75 gpm) o Pretreatment tests to evaluate various oxidants o Optimize filter efficiency

Upload: others

Post on 30-Apr-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FILTER

Bulletin No. 2200.4

FILTER REMEDIATION6739 S. Washington Ave., P.O. Box 469, Whittier, CA 90608

Fax: (562) 693-5257 e-mail: [email protected] Site: www.pfdiv.com

FIELD SERVICES

o Qualified personnel to inspect / troubleshoot existing filtration systems, perform pilot filter study, offer recommendations and a quotation for filter system remediationand recommissioning of filter system

UNDERDRAIN REPLACEMENT

o Inspect existing filter internalso Replace broken PVC underdrains / laterals with 316 L stainless steel

wedgewire components

MEDIA REPLACEMENT

o Multimedia replacement loads to improve filter performance

CONTROLS … VALVES … PRETREATMENT

o Replace original control panel with updated microprocessor based designo Replace butterfly valves/actuatorso Add pre- or post-treatment equipment including coagulant feed, oxidation/ disinfection equipment, water quality monitors/controls

BACKWASH WATER RECLAIM SYSTEM

o Reclaim up to 99% of total backwash volumeo Reduce or eliminate backwash water discharge

PILOT FILTERS

o Onsite pilot filter systems (flow rates from 0.50 gpm to 75 gpm)o Pretreatment tests to evaluate various oxidantso Optimize filter efficiency

Page 2: FILTER

_

TYPICAL IRON & MANGANESE REMOVAL SYSTEM

FILTER REMEDIATION DATA

● Client's Name / Address _________________________________________________

● Filter Manufacturer __________________ ● Media Type _______________________

● Filter Type □ Pressure □ Gravity

● □ Single Cell □ Multi Cell No. of Cells __________________________________

● Flow Rate ___________________ gpm ● No. of Filter Vessels ________________

● Filter Vessel(s) Size _________" Dia _________" Length

● Inlet / Outlet Pipe Size _____________" No. of Cells / Filter Vessel ________________

● Underdrain Type ___________ Underdrain Material of Construction _______________

● Condition of Underdrains _______________________________________________

● Access Manway(s) Dimensions _________" X _________"

● Water Quality Analysis (Attach Raw and Filtered Water Quality Data) Please refer to Pureflow Bulletin Nos. A2.92101.4 and A2.9422.4.

● System P & ID (Attach) ● Surface Wash / Air Scour Yes □ No □

● Type of Flow Control Valves and Locations _________________________________

● Backwash Water Supply (Source __________________ Flow Rate __________gpm)

● Backwash Water Temp ( __________°F) ● Filter Control: Automatic □ Manual □

● Existing Pretreatment Equipment ________________________________________

07/07 PUREFLOW © FILTRATION Division California Environmental Controls, Inc. Whittier, CA 90601