field quality working group - stephane sanfilippo at-mtm field quality of mq: warm/cold correlation....
TRANSCRIPT
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Field Quality of MQ:
Warm/cold correlation.
S.Sanfilippo, M.Calvi, N.Sammut, L.Bottura, P.Hagen, E.Todesco
AT-MTM/AT-MAS
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Measurements at 1.9 K (august 2005). 150 arc SSS tested at cold. Field strength : data from 29 MQ’s available
8 first MQ measured with the scanner (rotating coils). 21 MQ measured with the SSW system. SSW system is the reference system at 11850 A.
Field Quality (multipoles) :21 MQ’s cold tested in the SSS. 8 first MQ’s measured with the scanner, 13 MQ with long
shafts. 15 with X-section 1, 6 with X-section 2
6 MQ’s measured since the impact of the high on the W/C correlation was found out (November 2004):
MQ 114, MQ 120, MQ142, MQ145, MQ151,MQ173.
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Warm/cold correlation status for Gdl/i
Data for the scanner shifted by 17 units (offset between the two systems)
(established at nominal current)
58.1
58.2
58.3
58.4
58.5
58 58.1 58.2 58.3 58.4
warm TF (T / kA)
cold
TF
(T
/ kA
)
TF_scannerTF_SSWTF - out of W/C
Series5
17 units
w/c~20 units
w/c~4 units
6 apertures outside the correlation:MQ 120 (x2), MQ 145 (x2),
MQ114 (ap 1),MQ 142 (ap 2).
Criteria (Difference with T.C >>3w/c)
value-fit (unit) ap1 ap2
MQ120 -50 -40
MQ145 -21 -33
MQ114 -28 OK
MQ142 OK -27
T.C
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Warm/cold correlation status for b6(established at nominal current)
6 apertures outside the correlation:
MQ 120 (x2), MQ 145(x2), MQ114 (ap 1),MQ 142 (ap 2),
Criteria (Difference with T.C>>3w/c)
0
2
4
6
8
0 2 4 6 8warm b6- units @ 17 mm
cold
b6 (
unit
s @
17 m
m)
b6
b6 - out of W/C
w/c~ - 0.3 units
w/c~0.26 units
value-fit (unit) ap1 ap2
MQ120 2.74 1.97
MQ145 1.39 2.28
MQ114 1.56 OK
MQ142 OK 2.74
T.C
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Warm/cold correlation status for b6(established at injection current)
7 apertures outside the correlation:
MQ 120 (x2), MQ 145 (x2), MQ114 (ap 1),MQ 142 (x1) MQ 173 (ap1)
Criteria (Difference with T.C>>3w/c)
-5
-3
-1
1
3
5
0 2 4 6 8 10warm b6- units @ 17 mm
cold
b6 (
unit
s @
17 m
m)
b6
b6 - out of W/C
w/c~ - 3.70 units
w/c~0.4 units
value-fit (unit) ap1 ap2
MQ120 2.16 2.20
MQ145 1.34 2.06
MQ114 1.26 OK
MQ142 OK 1.60
MQ173 1.13 OK
T.C
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Warm/cold correlation status for b10(established at nominal current)
6 apertures outside the correlation:
MQ 120(x2), MQ 145(x2), MQ114 (ap 1),MQ 142 (ap2)
Criteria (Difference with T.C >>3w/c)
-0.4
-0.35
-0.3
-0.25
-0.2
-0.15
-0.1
-0.05
0
0.05
0.1
0.15
0.2
-0.4 -0.3 -0.2 -0.1 0 0.1 0.2warm b10- units @ 17 mm
cold
b10 (
unit
s @
17 m
m)
b10 outsideb10
w/c~ - 0.03 units
w/c~0.03 units
value-fit (unit) ap1 ap2
MQ120 -0.23 -0.16
MQ145 -0.1 -0.19
MQ114 -0.14 OK
MQ142 OK -0.22
T.C
Field Quality Working Group - Stephane Sanfilippo AT-MTM
Conclusions 6/58 apertures out of the warm/cold correlation for
TF,b6,b10. Analysis performed with 3 systems of measurements at
1.9 K. Magnets feature b6 close or below 2 units at warm.
Measurements to be performed with magnets where the is known and out of tolerance. reminder :20 SSS to be measured till the end of
2006.