field methods in environmental geology geos 3110

21
FIELD METHODS IN ENVIRONMENTAL GEOLOGY FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110 GEOS 3110

Upload: milly

Post on 07-Jan-2016

24 views

Category:

Documents


1 download

DESCRIPTION

FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110. GROUNDWATER CHARACTERIZATION. Groundwater Characterization. - Introduction - Parameters to be measured - Methodology. Introduction. WHAT IS A SLUG TEST In a slug test, an instantaneous change in water level is caused - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

FIELD METHODS IN ENVIRONMENTAL GEOLOGYFIELD METHODS IN ENVIRONMENTAL GEOLOGYGEOS 3110GEOS 3110

Page 2: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

GROUNDWATER CHARACTERIZATIONGROUNDWATER CHARACTERIZATION

Page 3: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Groundwater Characterization

- Introduction

- Parameters to be measured

- Methodology

Page 4: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Introduction

WHAT IS A SLUG TEST

In a slug test, an instantaneous change in water level is causedin a well, and then the rate at which water level returns to the initiallevel is measured.

TYPES:- falling-head tests- rising-head tests

Page 5: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Slug Test Types

Page 6: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

- Introduction

- Parameters to be measured

- Methodology

Groundwater Characterization

Page 7: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

- Depth-to-water surface

Parameters

Page 8: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Depth-to-water Surface

Electric Cable Water-Level Indicator

Page 9: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Depth-to-water Surface

Page 10: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

- Depth-to-water surface

- Hydraulic conductivity

Parameters

Page 11: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Hydraulic conductivity ( K ) is a measure of the ease with which a porous medium can transmit a fluid (such as water).

The term hydraulic conductivity is sometimes used interchangeblywith the term permeability.

Permeability is a characteristic only of the porous medium Hydraulic conductivity is a characteristic of both the porous mediumand the fluid.

Hydraulic Conductivity

Page 12: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Hydraulic Conductivity Computation

Page 13: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Hydraulic Conductivity Computation

K = r ln(L/R)2

2LT0

K - hydraulic conductivity ( m/sec)r - radius of the well (m)L - length of the saturation portion of the screen (m)R - radius of the screen (m)T - basic time lag which is read from the graph (sec)

For our case: r = 5 cm R = 5 cm L = 30.48 m

0

Page 14: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

- Depth-to-water surface

- Hydraulic conductivity

- Chemical data

Parameters

Page 15: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

See lab.3 - Water Quality Measurements

Perform the same analysis following the same procedures

Chemical Data

Page 16: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

- Introduction

- Parameters to be measured

- Methodology

Groundwater Characterization

Page 17: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

1. SLUG TEST

2. CHEMICAL ANALYSIS

Methodology

Page 18: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Slug Test Methodology- Before beginning the test, measure the depth-to-water level in well

- Measure depth to the bottom of the well to be sure that the well can accommodate the slug and water-level measuring device.

- Remove 4 liters of water using the bailer ( 1bailer = 1 liter )

- Begin measuring and recording the water level immediately after withdrawing the slug. The first object is to measure the lowest water level, which will occur within the first second after the slug is removed.

- Read and record the water level as it returns to normal, along with time of the measurements. Change the reading interval after every 5-10% changes in the readings. Reading interval: 15 sec, 30 sec, 1 min, 5 min.

- Stop the test after 60 % to 80% of the initial head has been recovered.

Page 19: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Slug Test Methodology

Page 20: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110

Slug Test Methodology1. Determine the Ho - the maximum level below the initial level to which the water falls immediately after the slug has been removed. Find Ho from subtracting the depth to water before the test from the depth to water immediately after the slug has been removed.

2. Compute H-Ho and devide the result to Ho. (drawdown)

3. Construct the graph Time vs. Drawdown. The Y axis have to be a logarithmic scale.

4. Define the best linear fit of these points.

5. Determine the To value from the graph. This value correspond to a drawdown equal with 0.37.

6. Use the formula to compute the hydraulic conductivity.

Page 21: FIELD METHODS IN ENVIRONMENTAL GEOLOGY GEOS 3110