february 19, 2016 williams...
TRANSCRIPT
![Page 1: FEBRUARY 19, 2016 WILLIAMS AVENUEfacilities.nmsu.edu/wp-content/uploads/sites/57/2016/03/AiM-2836... · 1014 SOUTH MAIN STREET LAS CRUCES P 575 528 0022 WILLIAMS DESIGN GROUP INC](https://reader031.vdocuments.us/reader031/viewer/2022011918/5ffd87c3bf60933d9301e762/html5/thumbnails/1.jpg)
RE
SE
AR
CH
D
RIV
E
W
I
L
L
I
A
M
S
A
V
E
N
U
E
O
F
F
I
C
E
C
E
N
T
E
R
G
E
N
E
S
I
S
3
9
5
C
E
N
T
E
R
D
R
I
V
E
S
A
M
S
T
E
E
L
W
A
Y
420 CENTER DR, LAS CRUCES, NM
CERVANTES COMMUNITY CENTER
DRAWING INDEX
SITE LOCATION MAP
PROJECT
LOCATION
TRUE
NORTH
DESIGN DEVELOPMENT
T1.1
JQ
MO
NORTH BUILDING RENOVATIONS
SHEET NO.
CHECKED BY:
DRAWN BY:
F 575 528 0023
NEW MEXICO 88005
1014 SOUTH MAIN STREETLAS CRUCES
P 575 528 0022
WILLIAMS DESIGN GROUP INC
RE
VIS
ION
S
PROJECT NO.
206-87
DE
SC
RIP
TIO
ND
ATE
SYM
BO
L
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit written permissionof Williams Design Group, Inc.
All reports, plans, specifications,computer files, field data and otherdocuments and instruments preparedby the Architect as instruments ofservice shall remain the property ofthe Architect. The Architect shallretain all common law, statutory, andother reserved rights, including thecopyright thereto.
Copyright © 2016 Williams DesignGroup, Inc. All rights reserved.
CE
RVA
NTE
S C
OM
MU
NIT
Y C
EN
TER
LA
S C
RU
CE
S, N
M 8
8005
NE
W M
EXI
CO
STA
TE U
NIV
ER
SIT
Y N
MS
U F
AC
ILIT
IES
DE
SIG
N42
0 C
EN
TER
DR
.
DE
SIG
N D
EVE
LOP
ME
NT
02/2
6/16
NO
RTH
BU
ILD
ING
RE
NO
VATI
ON
SD
D
TITLE SHEET
CODE EVALUATION
PROJECT DATA
NEW MEXICO STATE UNIVERSITY
FEBRUARY 19, 2016
WDG PROJECT NO: 206-87
ARCHITECT
WDG ARCHITECTS
WILLIAMS DESIGN GROUP, INC.
1014 S. MAIN
LAS CRUCES, NM 88005
P. 575.528.0022
F. 575.528.0023
CONTACT: DAVID CLARKE
CONSULTANTS
RBM ENGINEERING
ph. (575) 647-1554
1065 SOUTH MAIN STREET BLDG D SUITE A
MECHANICAL / PLUMBING / ELECTRICAL
LAS CRUCES, NM 88005
Contact: BOB BEASLEY
TITLE SHEET
T1.1 PROJECT DATA, VICINITY MAP, INDEX
ARCHITECTURAL
A1.1 DEMOLITION PLANS AND REVISED PLANS
A2.1 SCHEDULES AND DOOR DETAILS
MECHANICAL
M1.1 HVAC PLANS AND NOTES
ELECTRICAL
E0.1 ELECTRICAL RISER, NOTES AND DETAILS
E1.1 ELECTRICAL PLANS COMMUNITY BUILDING
OWNER
![Page 2: FEBRUARY 19, 2016 WILLIAMS AVENUEfacilities.nmsu.edu/wp-content/uploads/sites/57/2016/03/AiM-2836... · 1014 SOUTH MAIN STREET LAS CRUCES P 575 528 0022 WILLIAMS DESIGN GROUP INC](https://reader031.vdocuments.us/reader031/viewer/2022011918/5ffd87c3bf60933d9301e762/html5/thumbnails/2.jpg)
100
102
103
104
101
KEYED NOTES
GENERAL NOTES
1/4" = 1'-0"
DEMOLITION FLOOR PLAN
A1.1
1
PROJECT
NORTH
DEMO KEYED NOTES
DEMOLITION,
REVISED FLOOR
PLAN & CEILING
PLAN
A1.1
JQ
MO
1/4" = 1'-0"
REVISED FLOOR PLAN
A1.1
2
PROJECT
NORTH
1/4" = 1'-0"
REFLECTED CEILING PLAN
A1.1
4
PROJECT
NORTH
SHEET NO.
CHECKED BY:
DRAWN BY:
F 575 528 0023
NEW MEXICO 88005
1014 SOUTH MAIN STREETLAS CRUCES
P 575 528 0022
WILLIAMS DESIGN GROUP INC
RE
VIS
ION
S
PROJECT NO.
206-87
DE
SC
RIP
TIO
ND
ATE
SYM
BO
L
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit written permissionof Williams Design Group, Inc.
All reports, plans, specifications,computer files, field data and otherdocuments and instruments preparedby the Architect as instruments ofservice shall remain the property ofthe Architect. The Architect shallretain all common law, statutory, andother reserved rights, including thecopyright thereto.
Copyright © 2016 Williams DesignGroup, Inc. All rights reserved.
CE
RVA
NTE
S C
OM
MU
NIT
Y C
EN
TER
LA
S C
RU
CE
S, N
M 8
8005
NE
W M
EXI
CO
STA
TE U
NIV
ER
SIT
Y N
MS
U F
AC
ILIT
IES
DE
SIG
N42
0 C
EN
TER
DR
.
DE
SIG
N D
EVE
LOP
ME
NT
02/2
6/16
NO
RTH
BU
ILD
ING
RE
NO
VATI
ON
SD
D
1/4" = 1'-0"
DEMOLITION CEILING PLAN
A1.1
3
PROJECT
NORTH
![Page 3: FEBRUARY 19, 2016 WILLIAMS AVENUEfacilities.nmsu.edu/wp-content/uploads/sites/57/2016/03/AiM-2836... · 1014 SOUTH MAIN STREET LAS CRUCES P 575 528 0022 WILLIAMS DESIGN GROUP INC](https://reader031.vdocuments.us/reader031/viewer/2022011918/5ffd87c3bf60933d9301e762/html5/thumbnails/3.jpg)
1
SOLID CORE DOOR TO
MATCH EXISTING
1A
ALUMINUM FRAME TO
MATCH EXISTING
SOUND BATT.
INSULATION
FRAMING AT 16" O.C.
EACH SIDE
5/8" GYP.-BRD.
INT. PARTITION WALL
5
8
" 3
1
2
"
5
8
"
4
3
4
"
3
1
2
"
5
8
"
5
8
"
4
3
4
"
SECTION
PLAN VIEW
6"
2"x4" WOOD STUD
BASE
SOUND BATT.
INSULATION
2"x4" WOOD STUDS
5/8" GYP. BOARD
CEILING GRID
SUSPENDED ACOUSTICAL
CEILING
TO DECK - TYP
WOOD STUD
RUNNER TRACK TO
BOTTOM OF DECK
A2.1
J.Q.
DWC
SCHEDULES,DOOR AND
WALL DETAILS
DOOR SCHEDULE
MATERIALTYPENO.
DOOR
SIZE THK. TYPESET
HDW
ROOM FINISH SCHEDULE
NOTES
BASE
RM. NAMERM.#
FLOOR CEILING
WALLS
SN E W
CEILING
HEIGHT
FRAME
DEPTH
REMARKS
NOTES
REMARKS
ROOM FINISH CODES
KEYED NOTES
1. 2"x4" WOOD STUDS @ 16" O.C.
2.
5
8
" GYPSUM BOARD.
3. METAL CORNER BEAD.
4. R-19 SOUND ATTENUATION INSULATION.
5. CONTINUOUS SEALANT.
6. KAWNEER "ENCORE" ALUMINUM FRAME OR APPROVED
EQUAL.
7. 2X6 WOOD STUD HEADER.
8. DOUBLE WOOD STUD @ ALL JAMBS-TYP.
9. DOOR AS SCHEDULED.
10. WOOD SHIM AS REQUIRED.
11. 4" BASE AS SCHEDULED.
12. 3/4" PLYWOOD SHELVES-PAINTED.
13. PAINTED GYPSUM BOARD WALL.
14. WOOD CLEATS-TYP.
DOOR HEAD DETAIL DOOR JAMB DETAIL
1. DOOR HARDWARE TO MATCH EXISTING .
SHEET NO.
CHECKED BY:
DRAWN BY:
F 575 528 0023
NEW MEXICO 88005
1014 SOUTH MAIN STREETLAS CRUCES
P 575 528 0022
WILLIAMS DESIGN GROUP INC
RE
VIS
ION
S
PROJECT NO.
206-87
DE
SC
RIP
TIO
ND
ATE
SYM
BO
L
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit written permissionof Williams Design Group, Inc.
All reports, plans, specifications,computer files, field data and otherdocuments and instruments preparedby the Architect as instruments ofservice shall remain the property ofthe Architect. The Architect shallretain all common law, statutory, andother reserved rights, including thecopyright thereto.
Copyright © 2016 Williams DesignGroup, Inc. All rights reserved.
CE
RVA
NTE
S C
OM
MU
NIT
Y C
EN
TER
LA
S C
RU
CE
S, N
M 8
8005
NE
W M
EXI
CO
STA
TE U
NIV
ER
SIT
Y N
MS
U F
AC
ILIT
IES
DE
SIG
N42
0 C
EN
TER
DR
.
DE
SIG
N D
EVE
LOP
ME
NT
02/2
6/16
NO
RTH
BU
ILD
ING
RE
NO
VATI
ON
SD
D
SCALE: 1" = 1'-0"
INTERIOR ELEVATION
![Page 4: FEBRUARY 19, 2016 WILLIAMS AVENUEfacilities.nmsu.edu/wp-content/uploads/sites/57/2016/03/AiM-2836... · 1014 SOUTH MAIN STREET LAS CRUCES P 575 528 0022 WILLIAMS DESIGN GROUP INC](https://reader031.vdocuments.us/reader031/viewer/2022011918/5ffd87c3bf60933d9301e762/html5/thumbnails/4.jpg)
DRAWING KEYED NOTES:
1065 S. MAIN ST. BLDG D STE. A
LAS CRUCES, NM 88005
(575) 647-1554
FAX (575) 647-1563
SHEET NO.
CHECKED BY:
DRAWN BY:
F 575 528 0023
NEW MEXICO 88005
1014 SOUTH MAIN STREETLAS CRUCES
P 575 528 0022
WILLIAMS DESIGN GROUP INC
RE
VIS
ION
S
PROJECT NO.
206-87
DE
SC
RIP
TIO
ND
ATE
SYM
BO
L
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit written permissionof Williams Design Group, Inc.
All reports, plans, specifications,computer files, field data and otherdocuments and instruments preparedby the Architect as instruments ofservice shall remain the property ofthe Architect. The Architect shallretain all common law, statutory, andother reserved rights, including thecopyright thereto.
Copyright © 2016 Williams DesignGroup, Inc. All rights reserved.
CE
RVA
NTE
S C
OM
MU
NIT
Y C
EN
TER
LA
S C
RU
CE
S, N
M 8
8005
NE
W M
EXI
CO
STA
TE U
NIV
ER
SIT
Y N
MS
U F
AC
ILIT
IES
DE
SIG
N42
0 C
EN
TER
DR
.
DE
SIG
N D
EVE
LOP
ME
NT
02/1
9/16
NO
RTH
BU
ILD
ING
RE
NO
VATI
ON
SD
D
HVAC PLANS
& NOTES
M1.1
CAD
RBM
NEW HVAC & PLUMBING PLANEXISTING / DEMOLITION HVAC & PLUMBING PLAN
DUCT CONNECTION SCHEMATIC
DIFFUSER SCHEDULE HVAC & PLUMBING SYMBOL LEGEND
HVAC & PLUMBING GENERAL NOTES:
DOCUMENT GENERAL NOTES:
![Page 5: FEBRUARY 19, 2016 WILLIAMS AVENUEfacilities.nmsu.edu/wp-content/uploads/sites/57/2016/03/AiM-2836... · 1014 SOUTH MAIN STREET LAS CRUCES P 575 528 0022 WILLIAMS DESIGN GROUP INC](https://reader031.vdocuments.us/reader031/viewer/2022011918/5ffd87c3bf60933d9301e762/html5/thumbnails/5.jpg)
1065 S. MAIN ST. BLDG D STE. A
LAS CRUCES, NM 88005
(575) 647-1554
FAX (575) 647-1563
SHEET NO.
CHECKED BY:
DRAWN BY:
F 575 528 0023
NEW MEXICO 88005
1014 SOUTH MAIN STREETLAS CRUCES
P 575 528 0022
WILLIAMS DESIGN GROUP INC
RE
VIS
ION
S
PROJECT NO.
206-87
DE
SC
RIP
TIO
ND
ATE
SYM
BO
L
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit written permissionof Williams Design Group, Inc.
All reports, plans, specifications,computer files, field data and otherdocuments and instruments preparedby the Architect as instruments ofservice shall remain the property ofthe Architect. The Architect shallretain all common law, statutory, andother reserved rights, including thecopyright thereto.
Copyright © 2016 Williams DesignGroup, Inc. All rights reserved.
CE
RVA
NTE
S C
OM
MU
NIT
Y C
EN
TER
LA
S C
RU
CE
S, N
M 8
8005
NE
W M
EXI
CO
STA
TE U
NIV
ER
SIT
Y N
MS
U F
AC
ILIT
IES
DE
SIG
N42
0 C
EN
TER
DR
.
DE
SIG
N D
EVE
LOP
ME
NT
02/1
9/16
NO
RTH
BU
ILD
ING
RE
NO
VATI
ON
SD
D
PARTIAL POWER RISER DIAGRAM
SHORT CIRCUIT CALC.
LOAD SUMMARY CALC.:
GENERAL NOTES:
STATE OF NEW MEXICO:
RISER KEYED NOTES:
is greater than or equal to zero, the building
______________________________________________________________
___________________________________________________________________________________
Fixture Lamp Description / Wattage Per Lamp / BallastID
minus the Section 3: Compliance Calculation
Design
Total Allowed Watts
Lighting PASSES:
If the complies.
Total Actual Watts
2
2
Interior Lighting Application WorksheetSoftware Version 3.9.0
Section 1: Allowed Lighting Power Calculation
Section 2: Proposed Lighting Power Calculation
Building Type
AFixture Fixture Description /
Total Allowed Watts =Office/Corridor (North Wing Bldg.)
check
2009
Office (North Wing Bldg.)
COM
Lamps/B
FloorArea(ft2)700
B
(C x D)Watt.Fixtures
Total Actual Watts =
Project Compliance =Total Actual Watts =Total Allowed Watts =
________________________
TotalAllowed
C# of
DFixture
(watts/ft2)Watts
1.0
Allowed
(B x C)Watts.
700
E
C D
2
4
64
64
128
256Office (700 sq. ft.)
Linear Fluorescent 1: A: 2' X 4' Lensed Troffer 2-Lamp/48" T8 32W (Super T8)/ Electronic
Linear Fluorescent 2: B/BE: 2' X 4' Lensed Fixture 2-Lamp/
700603
97
603
700
14% better than code
IECC
48" T8 32W (Super T8)/ Electronic2 3 64 192Linear Fluorescent 3: C/CE: 1' X 4' Wraparound 2-Lamp/
48" T8 32W/ Electronic1 1 27 27Linear Fluorescent 4: D: 1' X 3' Wraparound 1-Lamp/
36" T8 25W/ Electronic
ELECTRICAL
LEGEND, RISER,
NOTES AND
DETAILS
E0.1
CAD
RBM
ELECTRICAL SYMBOL LEGEND
LIGHT FIXTURE
CONDUIT, RACEWAYS, AND WIRING
WIRING DEVICES
HEIGHTS NOTED ARE TO
CENTER LINE FROM FLOOR.
MISCELLANEOUS
COMMUNICATION SYSTEMS
HEIGHTS NOTED ARE TO
CENTER LINE FROM FLOOR.
EQUIPMENT
![Page 6: FEBRUARY 19, 2016 WILLIAMS AVENUEfacilities.nmsu.edu/wp-content/uploads/sites/57/2016/03/AiM-2836... · 1014 SOUTH MAIN STREET LAS CRUCES P 575 528 0022 WILLIAMS DESIGN GROUP INC](https://reader031.vdocuments.us/reader031/viewer/2022011918/5ffd87c3bf60933d9301e762/html5/thumbnails/6.jpg)
NO WORK IN
THIS AREA
NO WORK IN
THIS AREA
NO WORK IN
THIS AREA
1065 S. MAIN ST. BLDG D STE. A
LAS CRUCES, NM 88005
(575) 647-1554
FAX (575) 647-1563
SHEET NO.
CHECKED BY:
DRAWN BY:
F 575 528 0023
NEW MEXICO 88005
1014 SOUTH MAIN STREETLAS CRUCES
P 575 528 0022
WILLIAMS DESIGN GROUP INC
RE
VIS
ION
S
PROJECT NO.
206-87
DE
SC
RIP
TIO
ND
ATE
SYM
BO
L
This document may not bereproduced in whole or part by anymeans, electronic or otherwisewithout the explicit written permissionof Williams Design Group, Inc.
All reports, plans, specifications,computer files, field data and otherdocuments and instruments preparedby the Architect as instruments ofservice shall remain the property ofthe Architect. The Architect shallretain all common law, statutory, andother reserved rights, including thecopyright thereto.
Copyright © 2016 Williams DesignGroup, Inc. All rights reserved.
CE
RVA
NTE
S C
OM
MU
NIT
Y C
EN
TER
LA
S C
RU
CE
S, N
M 8
8005
NE
W M
EXI
CO
STA
TE U
NIV
ER
SIT
Y N
MS
U F
AC
ILIT
IES
DE
SIG
N42
0 C
EN
TER
DR
.
DE
SIG
N D
EVE
LOP
ME
NT
02/1
9/16
NO
RTH
BU
ILD
ING
RE
NO
VATI
ON
SD
D
NEW WORK LIGHTING PLAN
NEW WORK POWER / SS PLAN
KEY PLAN
EXIST/DEMO ELECTRICAL PLAN
ELECTRICAL
PLANS
NORTH
BUILDING
E1.1
CAD
RBM
DEMO KEYED NOTES:
BOX DETAIL
DATA / OUTLET
OUTLET DETAIL
BACK-TO-BACK
DEMO GENERAL NOTES:
NEW WORK KEYED NOTES:
DATA/PHONE GEN. NOTES: