features - solstis...connection pe ±24 vdc ±24 vdc - 5 vdc ls1 ls2 ls3 n 208 vac control circuit...
TRANSCRIPT
-
Features
ULTR
AULTRAGeneRAL SpecificATionScenTRALiZeD moDeLS
ULTRA-700.0-TLULTRA-1050.0-TLULTRA-1400.0-TL
1AURoRA pLUS
The largest solar power inverter in the power-one Aurora product range, the new Ultra 1.4mW unit is designed with large utility-grade installations in mind.
This liquid-cooled, high-powered Aurora inverter is the largest pV inverter available in the market. The compact chassis gives maximum power for the minimum footprint.
industry-leading power conversion efficiencies of up to 98.7%, combined with high-speed maximum power point Tracking (mppT) channels, optimize energy harvesting across a wide array of operating conditions. Up to four independent mppT input channels offer maximum flexibility and energy harvesting.
This large inverter system significantly reduces the wiring requirements and on-site testing thanks to the presence of separated and dedicated compartments for Dc and Ac.
High performance utility grade inverter for large utility pV installations with 98.7% efficiencyoutdoor enclosure for unrestricted use under any environmental conditionspassive liquid cooling with total segregation of internal compartments assuring a 5-year maintenance cycleReduced susceptibility to a single fault. in case of a component failure, a maximum of 350kW will be lostextended mppT input voltage rangeDirect transformerless conversion to the 690 Vac output reduces Ac distribution costmaximum input voltage up to 1100 Vdc, high design flexibility and reduced Dc distribution losses for large scale pV plantsintegrated Dc and Ac distribution and protection. fully equipped for connection, additional accessories not requiredeasy installation and maintenance procedure. front extractible Dc/Ac converters and accessibility to all critical partsethernet communication and two independent RS-485 communication interfaces for inverter and intelligent string combiner monitoringcompliant to BDeW and feRc 661
•••••••••••
-
2 AURoRA pLUS
Block Diagram and Efficiency Curves
PVI-ULTRA
94,5%
95,0%
95,5%
96,0%
96,5%
97,0%
97,5%
98,0%
98,5%
99,0%
650 Vdc
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
E�ci
ency
, %
% of Rated Output Power
BLOCK DIAGRAM OF ULTRA-1400.0-TL
AC BREAKER
TRANSFORMER EXT.
690V/MV (15kW/20kW)1400KVA
RST
MAIN AC POWERCONNECTION
PE
±24 VDC
±24 VDC
- 5 VDC
LS3 NLS2LS1
208 VACCONTROL CIRCUIT
AC BREAKER
RSTN
PE
AUX POWERCONNECTION
TO EACH 350.0 Kw MODULE
DCBREAKER
OVR
CONTROL CIRCUIT
ACFUSE
EMIFILTER
ACFUSE
EMIFILTER
ACFUSE
EMIFILTER
ACFUSE
EMIFILTER
DCBREAKER
OVR
INVERTER MODULE 350kW
AC BREAKER
DCBREAKER
OVR
DCBREAKER
OVR
CONTROL CIRCUIT
INVERTER MODULE 350kW
CONTROL CIRCUIT
INVERTER MODULE 350kW
CONTROL CIRCUIT
INVERTER MODULE 350kW
LINEFILTER
MODULE
ACCONTACTMODULE
BULKCAPS
MODULE
DC / ACINVERTERMODULE
LINEFILTER
MODULE
ACCONTACTMODULE
BULKCAPS
MODULE
DC / ACINVERTERMODULE
LINEFILTER
MODULE
ACCONTACTMODULE
BULKCAPS
MODULE
DC / ACINVERTERMODULE
LINEFILTER
MODULE
ACCONTACTMODULE
BULKCAPS
MODULE
DC / ACINVERTERMODULE
IN 1 (+)
IN 1 (-)
PV ARRAY 1 (+)
APV ARR Y 1 (-)
PV ARRAY 2 (+)
APV ARR Y 2 (-)
PV ARRAY 3 (+)
APV ARR Y 3 (-)
PV ARRAY 24 (+)
APV ARR Y 24 (-)
RECOMBINER
IN 2 (+)
IN 2 (-)
IN 3 (+)
IN 3 (-)
IN 4 (+)
IN 4 (-)
-
3AURoRA pLUS
PARAMETER ULTRA-700.0-TL ULTRA-1050.0-TL ULTRA-1400.0-TL
Input SideMPPT Input Range (VMPPTmin,r...VMPPTmax,r) 350...950 VMPPT Input Range (VMPPTmin,f...VMPPTmax,f) at Full Power 500...900 VAbsolute Maximum Input Voltage (Vmax,abs) 1100 VNumber of Independent MPPT Multi-Master 2 3 4Number of Independent MPPT Master/Slave 1 not applicable not applicableNumber of Independent MPPT Multi-Master/Slave 1 2 2Maximum Combined Input Current (Idcmaxc) 1440 A 1440 A + 720 A 1440 A + 1440 AMaximum Input Current for Each Module (Idcmax,m) 720 ANumber of DC Inputs Pairs 12 18 24DC Connections Type 12 x 50mm2 (m8) 18 x 50mm2 (m8) 24 x 50mm2 (m8) Input ProtectionReverse Polarity Protection Yes, via input breakerInput Over Voltage Protection - Varistor 4 for each module 6 for each module 8 for each modulePhotovoltaic Array Isolation Control According to local standard with alarmFuse Size for Each Input Pair 125 A / 1100 V Output SideAC Grid Connection (Vacmin...Vacmax) Three phaseRated Power (Pac,r) 700 kW 1050 kW 1400 kWRated Grid Voltage (Vac,r) 690 Vac / peAC Voltage Range (Vacmin...Vacmax) 621...759 Vac 1
Maximum Output Current (Iac,max) 590 A 876 A 1168 ARated Frequency (fr) 50/60 HzFrequency Range (fmin... fmax) 47...53 / 57...63 Hz
2
Nominal Power Factor (Cosphiac,r) < 0.995 (adj. ± 0.90)Total Harmonic Distortion < 3% (@ pac,r)AC Connection Type 2 x 240 mm2 (m12) 3 x 240 mm2 (m12) 4 x 240 mm2 (m12)Output ProtectionAnti-Islanding Protection According to local standardOutput Overvoltage Protection - Varistor YesAC Circuit Breaker 3 x 630 A / 40 kANight Time Disconnect YesOperating PerformanceMaximum Efficiency (ηmax) 98.7%Weighted Efficiency (EURO/CEC) 98.2% / 98.2%Stand-by Consumption/Night-time power loss < 90 W < 135 W < 180 WAuxiliary Supply 3 x 400 Vac / n /peAuxiliary Supply Consumption < 0.35% of pac,r < 0.40 % of pac,r < 0.65 % of pac,rAuxiliary Supply Consumption without Cooling < 0.08% of pac,r < 0.08% of pac,r < 0.08% of pac,rInverter Switching Frequency 9 kHzCommunicationWired Local Monitoring
1 x RS485 (inc.)pVi-USB-RS485_232 (opt.)
Remote Monitoring pVi-Aec-eVo (opt.), AURoRA-UniVeRSAL (opt.)AURORA String Combiner 1 x RS485 (inc.) pVi-STRinGcomB (opt.)User Interface TfT LcD 5.7”Environmental
Ambient Temperature Range -20...+ 60°c/-4...140°f with derating above 50°c/122°f -40...+ 60°c/-40...140°f with derating above 50°c/122°f (opt.)Relative Humidity 0...100% condensingNoise Emission < 78 dB(A) @ 1 m Maximum Operating Altitude without Derating 1000 m / 3280 ftPhysical Environmental Protection Rating ip 65Cooling passive liquid and air forcedRequired Air Cooling Flow not applicable
Dimension (H x W x D) 2938mm x 3000mm x 1520mm / 115.7 “ x 118.1” x 59.9”2938mm x 3700mm x 1520mm /
115.7 “ x 145.7” x 59.9”2938mm x 4400mm x 1520mm /
115.7 “ x 173.2” x 59.9”Weight < 2000 kg / 4409 lb < 2500 kg / 5521 lb < 3500 kg / 7716 lbWeight of the module < 50 kg / 100 lbSafetyTransformer no 3
Marking ceSafety and EMC Standard en 50178, en61000-6-2, en61000-6-4, en61000-3-11, en61000-3-12Grid Standard enel Guideline, BDeW, feRc 661
1 The Ac Voltage Range may vary depending on specific country grid standard2 The frequency Range may vary depending on specific country grid standard2 optionally provided within external cabin
-
www.power-one.com
4 AURoRA pLUS
Ver.
2011
-01.
2-en
Power-One Renewable Energy Worldwide Sales OfficesCountry name/Region Telephone emailAustralia Asia pacific +61 2 9735 3111 [email protected] Asia pacific +86 755 2988 5888 ext.5588 [email protected] Asia pacific +65 6896 3363 [email protected] europe 00 800 00287672 choix n°4 [email protected] europe +49 7641 955 2020 [email protected] europe +39 055 9195 396 [email protected] europe +34 629253564 [email protected] Kingdom europe +44 1903 823 323 [email protected] middle east +971 50 100 4142 [email protected] north America +1 877 261-1374 [email protected] East north America +1 877 261-1374 [email protected] Central north America +1 877 261-1374 [email protected] West north America +1 877 261-1374 [email protected]