features of new incyte™ software facilitate sophisticated flow cytometry analysis

6
Data Sheet Introduction Advances in flow cytometry applications and new instrument technologies such as plate-based automation have enabled experiments with much larger scope. However, this rapid expansion of technology has outpaced the functionality of traditional analysis tools and creates a bottleneck by forcing the user to analyze data on a tedious, run-by-run basis. Users must also frequently export data to other programs to obtain their data, limiting real-time determinations of significant data trends. EMD Millipore’s new InCyte™ software enables users to focus on their experiments as a whole, while still providing the details in a clear format. Extensive use of drag-and-drop features simplifies the setup & manipulation of plots, while automated compensation makes it easy to perform complex, multi-color assays. Entire plates of data can now be analyzed in the time it would previously require to analyze a single sample, and the instant update feature responds immediately in real time to change analysis conditions for viewing. These features provide a simple and rapid means to attain a macroscopic view of experiment “hits” and easily compare different experiments in real time. The Application Note Features of New InCyte Software Facilitate Sophisticated Flow Cytometry Analysis following overview of InCyte™ software illustrates examples of analyses made possible by the many unique capabilities of the new InCyte™ software. These capabilities provide users with experiment-level visualization, facilitating the rapid assessment of the biological significance of data. EMD Millipore is a division of Merck KGaA, Darmstadt, Germany

Upload: emd-millipore-bioscience

Post on 22-Oct-2014

50 views

Category:

Documents


1 download

DESCRIPTION

EMD Millipore’s new InCyte™ software enables users to focus on their experiments as a whole, while still providing the details in a clear format. Extensive use of drag-and-drop features simplifies the setup & manipulation of plots, while automated compensation makes it easy to perform complex, multi-color assays. Entire plates of data can now be analyzed in the time it would previously require to analyze a single sample, and the instant update feature responds immediately in real time to change analysis conditions for viewing. These features provide a simple and rapid means to attain a macroscopic view of experiment “hits” and easily compare different experiments in real time. The following overview of InCyte™ software illustrates examples of analyses made possible by the many unique capabilities of the new InCyte™ software. These capabilities provide users with experiment-level visualization, facilitating the rapid assessment of the biological significance of data.

TRANSCRIPT

Page 1: Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

Data Sheet

IntroductionAdvances in flow cytometry applications and new instrument technologies such as plate-based automation have enabled experiments with much larger scope. However, this rapid expansion of technology has outpaced the functionality of traditional analysis tools and creates a bottleneck by forcing the user to analyze data on a tedious, run-by-run basis. Users must also frequently export data to other programs to obtain their data, limiting real-time determinations of significant data trends.

EMD Millipore’s new InCyte™ software enables users to focus on their experiments as a whole, while still providing the details in a clear format. Extensive use of drag-and-drop features simplifies the setup & manipulation of plots, while automated compensation makes it easy to perform complex, multi-color assays. Entire plates of data can now be analyzed in the time it would previously require to analyze a single sample, and the instant update feature responds immediately in real time to change analysis conditions for viewing. These features provide a simple and rapid means to attain a macroscopic view of experiment “hits” and easily compare different experiments in real time. The

Application Note

Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

following overview of InCyte™ software illustrates examples of analyses made possible by the many unique capabilities of the new InCyte™ software. These capabilities provide users with experiment-level visualization, facilitating the rapid assessment of the biological significance of data.

EMD Millipore is a division of Merck KGaA, Darmstadt, Germany

Page 2: Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

flow cytometer and analyzed in InCyte™ 2.1 software. Analyzing data as shown allows the user to quickly identify hit compounds or broad patterns of change with respect to perturbation of experimental conditions.

Example Methods and Data 1. Screening of Cytoactive CompoundsJurkat cells in microtiter plates were treated with multiple cytotoxic compounds for 4 h and 24 h. Cells were stained using EMD Millipore’s FlowCellect™ MitoDamage, FlowCellect™ Cytochrome c, or guava® Caspase 8 & 9 kits. Data were acquired on an guava easyCyte™ 8HT benchtop

Figure 1. Cells were analyzed on a guava easyCyte™ flow cytometer and percent population data were compared in a heat map format using EMD Millipore’s InCyte™ Software. InCyte™ software allowed for rapid identification of hit compounds and comparison of all 6 parameters simultaneously, as shown in the pie charts above. The data show 80 of the 160 compounds analyzed.

4 HOUR DATA

24 HOUR DATA

7-AAD MitoSense Red

Annexin VCaspase 9

Cytochromec

Caspase 8

0-20% 20-40% 40-60% 60-80% 80-100%

Screening of cytoactive compounds using multiple cell health markers in combination with InCyte™ software’s heat mapping feature

INTENSITy OF SIGNALS

Page 3: Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

2. IC50/EC50 DeterminationDrag-and-drop gating on InCyte™ software, combined with the EC50/IC50 curve feature, makes quantifying biological responses as easy as a few mouse clicks. Jurkat cells were treated with various concentrations of apoptosis inducers, gambogic acid and etoposide,

for 4 hours at 37 ºC. Following apoptotic induction, cells were stained using EMD Millipore’s FlowCellect™ Cytochrome c kit. Samples were acquired on a guava easyCyte™ 8HT instrument and analyzed in InCyte™ 2.1 software.

Figure 2. InCyte™ software enables drag-and-drop gating, combined with heat map visualization, for easy IC50 determinations. (A) IC50 curve and results for gambogic acid and (B) EC50 curve and results for etoposide, both on Jurkat cells.

IC50/EC50 determination within InCyte™ software

A B

Page 4: Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

3. Sample Pooling For Detecting Rare EventsIn several instances, the population of interest may be a small % of the population such that a statistically significant number of relevant events can be difficult to acquire. InCyte™ software’s new sample pooling feature enables the user to combine multiple wells of the same sample as a single sample to distinguishlow occurring events.

Human adult blood was stained with a cocktail containing CD45 PerCP-Cy5.5, CD3 FITC, and CD19 for 20 minutes at room temperature. Following staining, cells were lysed with guava® lysing solution containing 0.2% paraformaldehyde (PFA) for 20 minutes at room temperature. Data were acquired on a guava easyCyte™ 8HT and analyzed in InCyte™ 2.1 software.

Figure 3. Sample pooling using a population with a low number of occurrences. Data from B cells in adult human blood show the gating strategy for a single well as well as the pooled sample of 3 wells.

Sample pooling: a software-based solution for analyzing low-frequency events

4. Colored Back-gating Locating a specific population within multiparameter analyses can be important for displaying and analyzing data. InCyte™ software’s simplified method for multi-color back-gating allows the user to easily gate populations into other plots. Gating with this feature allows users to monitor distinct populations throughout their experiments.

Human adult blood was stained with CD3 PerCP-Cy5.5 (lymphocytes), CD14 PE (monocytes), and CD15 FITC (granulocytes) for 15 minutes at room temperature. Following staining, cells were lysed with guava® lysing solution containing 0.2% PFA for 15 minutes at room temperature. Data were acquired on a guava easyCyte™ 8HT instrument and analyzed in InCyte™ 2.1 software.

Figure 4. Color back-gating for a standard 3 part differential plot. The data above show the 3-color gating of the lymphocyte (Red events gated in Plot A), monocyte (Yellow events gated in Plot B), and granulocyte (Green events gated in Plot B) populations, as defined by fluorescent antibody staining, into a three-part differential displayed in Plot C as forward vs. side scatter.

Color back-gating: multi-color displays for advanced fluorescent analysis of heterogeneous samples

9000

7000

6000

3000

1000

0

100 101 102 103 104

Side

Sca

tter

(SSC

-HLi

n)

CD15

FIT

C

CD3 PerCP-Cy5.5

9000

7000

6000

3000

1000

0

Side

Sca

tter

(SSC

-HLi

n)

Forward Scatter

Granulocytes

MonocytesLymphocytes

100 101 102 103 104 0 1000 3000 5000 7000 9000

100

101

102

103

104

CD14 PE

A B C

Gated toCD45-PerCP-Cy5.5 cells

CD3 FITCNegative Cells

CD19 APC Positive cells (B Cell Count)

A

1 2 3

B

Low event number

1 well

An adequate number of events for statistically significant results.

3 wells pooled

Gated to

Page 5: Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

5. Semi-automated Compensation Performing compensation prior to acquisition for multi-color experiments is often cumbersome, wastes a large amount of sample, and can lead to false positives or negatives if not performed correctly. InCyte™ software’s post acquisition semi-automated compensation sets up the compensation easily by using single color controls provided by the user, in combination with an established software algorithm. This feature can be combined with compensation during or post acquisitionto set samples up as needed.

Eliminating the complexity of compensation simplifies sample analysis enablesgreater confidence in the acquired results.

Adult Human blood was stained with various combinations of antibodies, then lysed with guava® lysing solution containing 0.2% PFA. Data were acquired on a guava easyCyte™ 8HT instrument and analyzed in InCyte™ 2.1 software.

Figure 5. Automated compensation on various samples. The data show the uncompensated data for various experiments (top panel) and the semi-automated compensation from InCyte™ software (bottom panel). As the data demonstrates, InCyte™ software’s semi-automated compensation performs as expected.

Color back-gating: multi-color displays for advanced fluorescent analysis of heterogeneous samples

100 101 102 103 104

100

101

102

103

104

CD3

PE-C

y5

CD8 APC100 101 102 103 104

100

101

102

103

104

CD15

FIT

C

CD14 PE

100 101 102 103 104

100

101

102

103

104

CD15

FIT

C

CD14 PE

100 101 102 103 104

100

101

102

103

104

CD3

PE-C

y5

CD4 PE100 101 102 103 104

100

101

102

103

104

CD45

PE-

Cy7

CD4 PE

100 101 102 103 104

100

101

102

103

104

CD3

PE-C

y5

CD4 PE100 101 102 103 104

100

101

102

103

104

CD45

PE-

Cy7

CD4 PE

Unco

mpe

nsat

edSe

mi-

auto

mat

edCo

mpe

nsat

ion

A

100 101 102 103 104

100

101

102

103

104

CD3

PE-C

y5

CD8 APC

B C

Page 6: Features of New InCyte™ Software Facilitate Sophisticated Flow Cytometry Analysis

Summary • InCyte™ software features heat maps that enable

comparative analysis of multiparameter data sets. Experiment-level visualization provides rapid identification of hits, trends, controls, and errors.

• Drag-and-drop gating makes both simple and complex gating strategies effortless. On-board IC50 and EC50 quantitation provides greater analysis capabilities within one software package.

• “Instant Update” heat map and IC50/EC50 applications provide immediate feedback to changes in analysis parameters.

• Sample pooling provides for rare event analysis without the need for acquiring high numbers of events.

• Multi-color back-gating enhances the visualization of distinct event subsets in complex cell mixtures.

• Automated compensation, which can be performed before or after acquisition, eliminates the tedium and complexity of compensation to facilitate the performance of more sophisticated experiments.

For more information on InCyte™ software for acquisition and analysis on instruments, please contact your local EMD Millipore sales representative, or visit: www.millipore.com/flowcytometry

EMD Millipore, the M logo, InCyte, easyCyte, and FlowCellect are trademarks of Merck KGaA, Darmstadt, Germany.guava is a registered trademark of Merck KGaA, Darmstadt, Germany.Lit No. AN4478EN00 LS-SBU-12-06395 5/2012 Printed in the USA. © 2012 EMD Millipore Corporation, Billerica, MA USA. All rights reserved.

www.emdmillipore.com/offices

To Place an Order or ReceiveTechnical AssistanceIn the U.S. and Canada, call toll-free 1-800-645-5476

For other countries across Europe and the world, please visit: www.emdmillipore.com/offices

For Technical Service, please visit: www.emdmillipore.com/techservice

Get Connected! Join EMD Millipore Bioscience on your favorite social media outlet for the latest updates, news, products, innovations, and contests!

facebook.com/EMDMilliporeBioscience

twitter.com/EMDMilliporeBio