fe-iisb-14w mercury test report (rohs)

8
8/7/2019 FE-IISB-14w Mercury Test Report (RoHS) http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 1/8  Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 1 of 8 (supplementary) XIAMEN LONGSTAR LIGHTING CO., LTD 165 SIMING YUAN, TONGAN INDUSTRIAL ZONE, XIAMEN, CHINA 361100 Sample Description : ENERGY SAVING LAMP SGS Ref No. : XM12290292EC-18.5 Test Model No. : FE-IISB-14W, FE-IISB-13W, FE-IISB-15W Verification Period : DEC 07, 2009 TO JAN 07, 2010 Verification Requested :With reference to RoHS Directive 2002/95/EC, and its amendment directives Verification Method 1. Review was performed for the samples disjointed from the submitted articles and the related test reports submitted by the Applicant 2. Tests was performed for the samples indicated by the photos in the report with test methods reference to IEC 62321:2008: Procedures for the Determination of Levels of Six Regulated substances in Electrotechnical Products (1) Screening by XRF Spectroscopy (2) Wet Chemical Test Method a. Determination of Mercury by ICP. b. Determination of Hexavalent Chromium by Colorimetric Method. c. Determination of PBBs and PBDEs by GC/MS. Verification Results : Please refer to next page Verification Conclusion : Based on the review of previous reports and verification results of the submitted samples, the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments. Remark : According to declaration from client, the materials of other parts subject to verification in model FE-IISB-14W, FE-IISB-13W & FE-IISB-15W are the same as those in model FE-GU-14W (data and photos are shown on report GZ0912113871/CHEM) Signed for and on behalf of SGS-CSTC Ltd. ______________________ Shining Deng Sr. Engineer

Upload: drunkmunki

Post on 08-Apr-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 1/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 1 of 8

(supplementary) 

XIAMEN LONGSTAR LIGHTING CO., LTD165 SIMING YUAN, TONGAN INDUSTRIAL ZONE, XIAMEN, CHINA 361100

Sample Description : ENERGY SAVING LAMP

SGS Ref No. : XM12290292EC-18.5

Test Model No. : FE-IISB-14W, FE-IISB-13W, FE-IISB-15W

Verification Period : DEC 07, 2009 TO JAN 07, 2010

Verification Requested :With reference to RoHS Directive 2002/95/EC, and its amendment directives

Verification Method 1. Review was performed for the samples disjointed from the submitted articles andthe related test reports submitted by the Applicant

2. Tests was performed for the samples indicated by the photos in the report with

test methods reference to IEC 62321:2008: Procedures for theDetermination of Levels of Six Regulated substances in Electrotechnical Products(1) Screening by XRF Spectroscopy

(2) Wet Chemical Test Methoda. Determination of Mercury by ICP.

b. Determination of Hexavalent Chromium by Colorimetric Method.

c. Determination of PBBs and PBDEs by GC/MS.

Verification Results : Please refer to next page

Verification Conclusion : Based on the review of previous reports and verification results of the submittedsamples, the results comply with the RoHS Directive 2002/95/EC and itssubsequent amendments.

Remark : According to declaration from client, the materials of other parts subject toverification in model FE-IISB-14W, FE-IISB-13W & FE-IISB-15W are the same asthose in model FE-GU-14W (data and photos are shown on reportGZ0912113871/CHEM)

Signed for and on behalf ofSGS-CSTC Ltd.

______________________ Shining DengSr. Engineer

Page 2: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 2/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 2 of 8

(supplementary) 

Details on VerificationIn accordance with the result of material risk assessment, the following disjointed parts in the submitted sample havebeen verified.

PartNo.

Part NameRestricted

Substances

Resultsof

EDXRF(1)

No. of RelatedTest Report

Results inRelated Test

Report(mg/kg) 

Result of WetChemical

Testing(2)

(mg/kg) 

Conclusionon RoHS

SampleSubmitted /

ResubmittedDate

Cd BL \ \ ComplyPb BL \ \ Comply

Hg BL \ \ Comply

Cr6+

BL \ \ Comply

PBBs \ \ Comply

A1

Red plastic w/ black printing

(wire insulation)(connected w/ 

"PCB")PBDEs

BL

\ \ Comply

Dec 07, 2009

Cd BL \ \ Comply

Pb BL \ \ ComplyHg BL \ \ Comply

Cr6+

BL \ \ ComplyPBBs \ \ Comply

A2

Black plastic w/ white printing

(heat shrinkabletube) (on No.A1)

PBDEsBL

\ \ Comply

Dec 07, 2009

Cd BL \ \ Comply

Pb BL \ \ ComplyHg BL \ \ Comply

Cr6+

BL \ \ Comply

PBBs \ N.D. Comply

A3Black body w/ silvery printing(D4 on "PCB")

PBDEsIN

\ N.D. Comply

Dec 07, 2009

Cd BL \ \ ComplyPb BL \ \ Comply

Hg BL \ \ Comply

Cr6+ BL \ \ ComplyPBBs \ \ Comply

A4

Black body w/ 

brown printing(T2 on "PCB")

PBDEsBL

\ \ Comply

Dec 07, 2009

Cd BL \ \ ComplyPb BL \ \ Comply

Hg BL \ \ Comply

Cr6+ IN \ N.D. Comply

PBBs \ \ Comply

A5-C

Dk-green plasticshell w/ silveryprinting (C6 on

"PCB")

PBDEsBL

\ \ Comply

Dec 07, 2009/ Dec 21, 2009

Cd BL \ \ ComplyPb BL \ \ Comply

Hg IN \ 1.36mg/lamp

(See remark[1]

)Comply

Cr6+

BL \ \ Comply

PBBs \ \ \ 

A6Silver-grey metal(in transparent

glass)

PBDEs---

\ \ \ 

Dec 07, 2009

Page 3: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 3/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 3 of 8

(supplementary) 

PartNo.

Part NameRestricted

Substances

Resultsof

EDXRF(1)

No. of RelatedTest Report

Results inRelated Test

Report(mg/kg) 

Result of WetChemical

Testing(2)

(mg/kg) 

Conclusionon RoHS

SampleSubmitted /

ResubmittedDate

Cd BL \ \ Comply

Pb BL \ \ ComplyHg BL \ \ Comply

Cr6+

BL \ \ ComplyPBBs \ \ Comply

B1

Blue plastic w/ white printing

(outer shell) (C1on "PCB")

PBDEsBL

\ \ Comply

Dec 07, 2009

PartNo. Part Name

RestrictedSubstances

Results

ofEDXRF(1)

No. of RelatedTest Report

Results in

Related TestReport(mg/kg) 

Result of Wet

ChemicalTesting(2)

(mg/kg) 

Conclusionon RoHS

SampleSubmitted /

ResubmittedDate

Cd BL \ \ Comply

Pb BL \ \ Comply

Hg BL \ \ Comply

Cr6+

BL \ \ Comply

PBBs \ \ Comply

C1Transparentglass tube w/ white surface

PBDEsBL

\ \ Comply

Dec 07, 2009

Page 4: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 4/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 4 of 8

(supplementary) 

Remark

(1) (a) It is the result on total Br while test item on restricted substances is PBBs/PBDEs. It is the result on total Crwhile test item on restricted substances is Cr

6+.

(b) Results are obtained by EDXRF for primary screening, and further chemical testing by ICP (for Cd, Pb, Hg),UV-VIS (for CrVI) and GCMSD (for PBBs, PBDEs) is recommended to be performed, if the concentrationexceeds the below warning value according to IEC 62321:2008 (unit: mg/kg)

Element Polymer Metal Composite MaterialsCd BL≤ (70-3σ)< X <(130+3σ)≤ OL BL≤ (70-3σ)< X <(130+3σ)≤ OL LOD < X <(150+3σ)≤ OL

Pb BL≤ (700-3σ)< X <(1300+3σ)≤ OL BL≤ (700-3σ)< X <(1300+3σ)≤ OL BL≤ (500-3σ)< X <(1500+3σ)≤ OL Hg BL≤ (700-3σ)< X <(1300+3σ)≤ OL BL≤ (700-3σ)< X <(1300+3σ)≤ OL BL≤ (500-3σ)< X <(1500+3σ)≤ OL

Br BL≤

(300-3σ

)< X --- BL≤

(250-3σ

)< XCr BL ≤ (700-3σ)< X BL ≤ (700-3σ)< X BL≤ (500-3σ)< X

(c) OL = Over Limit, BL = Below Limit, IN = Inconclusive, LOD = Limit of Detection(d) The XRF screening test for RoHS elements – The reading may be different to the actual content in the

sample be of non-uniformity composition

(2) (a) mg/kg = ppm=0.0001%, N.D. = not detected (<MDL), --- = not conducted, \ = not available.(b) Unit and Method Detection Limit (MDL) in wet chemical test

Test Items Pb Cd Hg

Units mg/kg mg/kg mg/kg

MDL 2 2 2

The MDL for single compound of PBBs & PBDEs is 5 mg/kg and MDL of Cr6+

for polymer & compositesample is 2 mg/kg.

(c) According to IEC 62321:2008, result on Cr6+

for metal sample is shown as Positive/Negative. Negative =Absence of Cr

6+coating, Positive = Presence of Cr

6+coating.

Storage conditions and production date of the tested sample are unavailable and thus results of Cr(VI)represent status of the sample at the time of testing.

Remark[1]: According to the declaration from client, the source of Mercury could be from the compact fluorescentlamps, while Mercury in compact fluorescent lamps containing up to 5mg per lamp is exempted by RoHSregulatory (Directive 2002/95/EC of the European Parliament and of the council of 27 January 2003).

Page 5: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 5/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 5 of 8

(supplementary) 

Photo for original product

Photo for supplementary product

A

GZ0912113871/CHEM

GZ0912113875/CHEM

Page 6: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 6/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 6 of 8

(supplementary) 

B

C

GZ0912113875/CHEM

GZ0912113875/CHEM

Page 7: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 7/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 7 of 8

(supplementary) 

GZ0912113875/CHEM

GZ0912113875/CHEM

A3

A1 A5

A6

A2

A4

Page 8: FE-IISB-14w Mercury Test Report (RoHS)

8/7/2019 FE-IISB-14w Mercury Test Report (RoHS)

http://slidepdf.com/reader/full/fe-iisb-14w-mercury-test-report-rohs 8/8

 Verification Report No.: GZ0912113875/CHEM Date: JAN 07, 2010 Page 8 of 8

(supplementary) 

(SGS authenticate the photo on original report only)

*** End of Report *** 

GZ0912113875/CHEM

GZ0912113875/CHEM

B1

C1