1 Fatima Jinnah Medical University Lahore Tender Document Tender No. IT-0004 Supply & Installation of LAN & WLAN Equipment at Fatima Jinnah Medical University Lahore TENDER DOCUMENT TENDER No. IT- 0003

Upload: others

Post on 23-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

1

Fatima Jinnah Medical University

Lahore

Tender Document

Tender No. IT-0004

Supply & Installation of LAN & WLAN Equipment

at

Fatima Jinnah Medical University

Lahore

TENDER DOCUMENT

TENDER No. IT- 0003

Page 2: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

2

Supply & Installation of LAN & WLAN Equipment

at

Fatima Jinnah Medical University Lahore

TENDER PRICE Rs. 500/-

Last date of submission: __________________

FOR OFFICE USE ONLY

Serial No

Sold to: M/S

Date of Sale

Bank Challan No.

Date

Page 3: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

3

1. Overview

Fatima Jinnah Medical University, Lahore intends to purchase “Supply & Installation of LAN

& WLAN Equipment” as provided at Annex ‘A’. The supplier will be responsible for Supply,

delivery, installation and commissioning of all specified items, wherever required, at the

Fatima Jinnah Medical University Lahore. This document provides complete instructions for

bidders intending to participate in this Tender. 2. Instructions for Bidders

2.1. Response to the Tender (Bid) should be submitted in one part which shall include

two separately sealed envelopes of Technical Proposal and Financial Proposal before

11:00 AM on 04-01-2019. Technical Proposals will be opened on same day at 11:30 AM

in the presence of representatives of responding bidders, if any, and Financial Proposals

will be opened after completion of technical evaluation. The exact time and place for

opening of financial proposals will be informed to technically qualified bidders.

2.2. Responding bidder shall deliver two sealed copies of the bid. Each copy being

physically separate, bound, sealed andc labeled. Proposals shall be delivered at the

address given below.

Registrar

Fatima Jinnah Medical University, Lahore

2.3. Any queries regarding this proposal should be directed to the designated Technical

Contact Person listed below.

IT Department, FJMU

2.4. All bids must be submitted by filling the Annex ‘B’. Same should be enclosed in the

financial proposal. Bidder must use the same numbers and labels used in this Request for

Proposal.

Page 4: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

4

2.5. The original Tender Document duly signed and officially sealed by the bidder must be

submitted in whole with the proposals. Any conditional, ambiguous, incomplete,

supplementary or revised offer after the opening of tender shall not be entertained.

3. Technical Proposal Format

Bidders are required to include the following documents/information in their technical

proposals in the order given below:

i. The Name and Address

ii. Profile of company (Including Financial Profile)

iii. List of Previous/Current customers of related supplies, with contact person and

telephone/fax numbers.

iv. Detailed product design information

v. Copy of National Tax Registration Certificate

vi. Copy of Sales Tax Registration Certificate

vii. Bank letter of financial standing

viii. An affidavit on Rs 100/- Stamp Paper that currently they are not black listed or de-

barred by any Government/Semi-Government Department to participate in bidding and

to supply equipment. Failure to submit such affidavit may lead to disqualification.

ix. Any additional information the bidder may like to furnish e.g. repair/maintenance

other concerned facility

x. Detailed item specifications matched corresponding to the BOQ as given at Annex ‘A’

xi. Detailed project implementation schedule/Completion Schedule which includes the

delivery of items mentioned in the BOQ

xii. Signed and stamped Tender document

xiii. Bank Draft of the Earnest Money

4. Financial Proposal Format

Financial Proposal must include the following in the order given below:

i. Equipment prices duly entered on the form in the attached BOQ

ii. Validity period of the quoted price

iii. Any other Terms and Conditions

Page 5: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

5

5. Terms & Conditions

5.1. This invitation for bids is open to all national original Manufacturers/ Distributors/Agents

in Pakistan for Supply and installation.

5.2. All prices should be quoted in Pak Rupees and inclusive of all Government Taxes

& Levies.

5.3. A bank draft equal to 2% of the estimated cost should accompany the Tender as

Earnest Money drawn in favor of Fatima Jinnah Medical University, Lahore. The

Tender shall not be considered without Earnest Money. Bank guarantee will not be

accepted. Bank draft for Earnest Money should be placed with the Technical proposal.

5.4. Earnest Money for bidders not selected will be returned a minimum of two weeks after

announcement of award and returned to successful bidder after signing the contract. If the

selected bidder fails to sign the contract with in stipulated time, Earnest Money will be

forfeited.

5.5. A Bank draft of 5% of the total amount as Performance Guarantee will be provided by

the supplier in favor of Fatima Jinnah Medical University, Lahore within 10 days

after signing of the contract on judicial stamp paper of the value PKR. 1200/-which shall

remain valid for 12 months beyond delivery period. This performance guarantee will

be released after the completion of warranty/guarantee period, along with the

satisfactory completion report which will be intimated to the Seller and the Registrar

Fatima Jinnah Medical University, Lahore for their onward issuance of No Objection

Certificate (NOC) for the release of performance guarantee.

5.6. Fatima Jinnah Medical University reserves the right to accept / reject any or all

proposals without assigning any reason thereof.

5.7. The quantity of an order may vary depending on the quoted prices and the allocated

funds.

5.8. The decision of the FJMU procurement committee will be binding on all concerned and will

in no case be challenged in any forum.

5.9. FJMU Lahore reserves the right to modify the conditions / specifications of the Tender

Document with written intimation to all the participants who have purchased the

Tender Document.

5.10. Delivery period will be 30 days from the date of issuance of purchase order/supply

order.

Page 6: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

6

5.11. Delivery shall be completed according to the agreed upon schedule.

5.12. In case the selected bidder fails to execute the contract strictly in accordance with the terms

and conditions laid down in the contract, the Performance Guarantee shall be forfeited.

5.13. The University will get the item inspected at Fatima Jinnah Medical University, Lahore

and reject the item, if not found according to the stated specifications.

5.14. The University reserves the right to claim compensation for the losses caused by delay in the

delivery of equipment.

5.15. It is the sole responsibility of the bidder to comply with local, national and international

laws.

5.16. In case any supplies/material are found not in conformity with the specifications provided in

the tender, either on account of inferior quality, defective workmanship, faulty design, faulty

packing or is short supplied, or wrongly supplied, the supplier will replace the same

free of charges or pay the full cost of replacement.

5.17. All the proposals submitted will become the property of the University.

5.18. All prices should be valid for at least 60 days. Withdrawal or any modification of the

original offer within the validity period shall entitle the Fatima Jinnah Medical

University, Lahore to forfeit the Earnest Money in favor of the Fatima Jinnah Medical

University, Lahore and/or putting a ban on the future inquires or taking any other suitable

action against the bidder.

5.19. Delivery of the items will be free of charge at Fatima Jinnah Medical University, Lahore

during the office hours with a copy of Delivery Challan.

5.20. Items being ordered should be brand-new and according to order specification from the

current production and covered under normal warranty/guarantee etc. as mentioned in the

quote. Brochures mentioned and product details must be attached.

6. Tender Evaluation Criteria

All bids shall be evaluated on technical and financial merit. The Company Evaluation

Criteria is attached at Annex ‘C’ for reference. Technical evaluation process may include,

but not limited to the consideration of the following with respect to the functional requirements

given ahead:

a. Technical specifications of proposed item

Page 7: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

7

b. Company Profile

I. Age of the company

II. Financial strength of the bidder

Financial Evaluation process will be based on the consideration of the quoted price.

7. Undertaking On behalf of the company it is certified that we agree to the all the Instructions and Terms &

Conditions given in this Tender Document

Name of bidder…………………………………………………………………………………

Authorized person………………………………………………………………………………...

Authorized signature………………………………………………………………………………

Stamp………………………………………………………………………………………………

Office Address……………………………………………………………………………………

Tel No ………………………………………………………………………………………………

Fax No ……………………………………………………………………………………………

Page 8: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

8

Annex ‘A’

TECHNICAL SPECIFICATIONS

LOT 1

Network Switches & SFP Modules

SR. NO.

ITEM DESCRIPTION QTY.

01

24 Port Layer 2 Switch

1. Interfaces: 24 10/100/1000BASE-T + 2 100/1000 Mbps SFP ports 2. Duplex Mode: • Full/Half-duplex for 10/100 Mbps, Full-duplex for 1000 Mbps 3. Media Interface Exchange: Auto MDI/MDIX adjustment for all twisted-pair ports 4. Switching Capacity: minimum 52 Gbps or higher 5. MAC Address Table minimum 8K entries or higher 6. Static MAC Addresses minimum 256 entries or higher 7. Forwarding Rate minimum 38.7 Mpps or higher 8. Packet Buffer minimum 4 MB or higher 9. DRAM minimum DDR3 128 MB or higher 10. NVRAM minimum 32MB or higher 11. Power Input 100 to 240 V AC 50/60 Hz internal universal power supply 12. Should Support Advanced Layer 2 features. 13. Should support IEEE Features including Flow Control and Energy Efficient Ethernet (EEE).

03

02

28 Port PoE+ Switch

1. 24x 10/100/1000 PoE+ ports, 2x 1G RJ45 uplink-ports, 4x 1G SFP uplink-ports upgradable to 4x 10G SFP+ with license. 2. Out of Band Ethernet Port 10/100/1000Mbps RJ45, Console Port RJ45 to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity or Higher. 4. Forwarding Capacity 98Mpps or Higher. 5. Switch must support the following specification minimum 6. Minimum 1 GB DRAM or higher 7. Minimum 2 GB NVRAM or higher 8. Minimum 2MB Packet Buffer or higher 9. Minimum 370W(AC) PoE Power Budget or higher 10. Switch support 16k MAC address entries and 1000 Router entries. Also support the 4K VLAN, 32 PVLAN, 250 STP, 4k ARP and 8 port maximum Trunk. 11. Minimum 320Gbps of Aggregating Stacked Option or Higher

01

Page 9: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

9

12. Should support 12 Switch per Stack at Maximum Distance of 3 Km Capable. 13. Open Flow 1.3 Support for Future Integration with SDN Controller 14. Should support Hybrid Port Mode on all the Switch Ports 15. ISSU (In Service Software Update) 16. Hitless Fail Over to Auto Stand By Master Stack Controller 17. Should Support Basic Layer 3 Protocols (Should have capability to Enhance the Layer Function by adding license for Future Use) 18. QOS ACL Mapping and Marking of ToS/DSCP (CoS), ACL Mapping and Marking of 802.1p, ACL Mapping to Priority Queue, Classifying and Limiting Flows Based on TCP Flags, Honoring DSCP and 802.1p (CoS), Priority Flow Control (per device). 1 year Support Advanced Hardware Replacement (Next Business Day).

03

SFP Modules

Standards: IEEE 802.3u, Compliance: SFP + MSA Compliant, LC duplex connector, Data Transfer Rate: 55 Mbps, Wavelength:1310 nm, Optical Output Power: -20 ~ -10 dBm, Distance: 2 km, Special Features: Hot pluggable, Metal enclosure, Sensitivity: -32 dBm, Power consumption: 439 mW, Operating Temperature: 0 – 70 °C (32 - 158 °F), Operating Humidity: Max. 90% non-condensing, Dimensions: 13 x 53 x 10 mm (0.5 x 2.1 x 0.4 in), Weight: 18 g (0.6 oz.), Certifications: CE, FCC,

8

Note: Bidder must provide Warranty & Support of hardware equipment for atleast 1 year

LOT 2

LAN & WLAN Infrastructure

Sr. No

Item Description QTY.

01

WLAN Controller

1. Controller should be able to support up to 150 access points 2. Controller should support up to 4,000 concurrent users session. 3. 1+1 redundancy with auto synchronization should be Ruckus. 4. Controller must have two Gigabit Ethernet (10/100/1000) ports. 5. Support automatic channel adjustment 6. Support automatic transmits power adjustment on each AP to achieve optimal performance. 7. Controller must support integrated Captive portal 8. Support smart mesh networking and also show the mesh topology on floor plan. 9. Support 256 WLAN SSID on network. 10. Support integrated DHCP server 11. Controller should be able to present a customizable dashboard. 12. Controller should Support HotSpot 2.0 services. 13. System should support Dynamic Pre-shared Key with 63 bit

01

Page 10: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

10

unique Key Generated by Controller 14. System must detect the Rogue Access point and indicate malicious AP and Mac Spoofing. 15. System must prevent the clients to communicate with Malicious Access. 16. Controller should support Guest network and policies with ease of use. 17. Support for per SSID and user based rate limiting. 18. Controller should support WEP, WPA-TKIP, WPA2-AES, 802.11i. 19. Should support authentication via LDAP, Active Directory and RADIUS sever and also have the internal local database. 20. Support 802.1Q (VLAN) per SSID, dynamic VLANs and VLAN Pooling. 21. Controller should support Channel fly to automatically select the RF Channel with greater Throughput. 22. Controller should support ACL (Access list) layer 2, layer 3 and layer 4. 23. Controller should support the OS based policies for iOS, Android, windows and Linux. 24. Support Application visibility. 25. Controller have the ability to tunnel data from the access points to the controllers 26. Controller should support SMTP outbound authentication and TLS encryption. 27. Support SNMP v2 and v3 28. Device must be Wi-Fi Alliance Certified.

02

Wireless Access Points

The AP’s should support 802.11 a/b/g/n/ac standards and should be centrally managed by wireless controller device. 1. Access Point must support 802.11 ac (MU-MIMO) Wave II Standard. 2. The access point should work on 2.4GHz and 5 GHz band simultaneously. 3. Access Point should support 400 Mbps on 2.4 GHz and 867 Mbps on 5 GHz. 4. Access Point should support Channelization of 20 MHz, 40 MHz and 80 MHz 5. Access point must work on 2 x 2 with 2 Spatial Streams (MU-MIMO). 6. Support backward compatibility with legacy 802.11 Clients. 7. Access Point should support dual Polarized Integrated smart Directional antennas 8. Adaptive Polarization Diversity- MRC (PD-MRC) should support. 9. Integrated Antenna elements must support 128 unique antenna patterns for better coverage and interference rejection.

18

Page 11: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

11

10. Support Beamflex and Beamflex+ Technology. 11. Device must support 3 dBi physical antenna gain and 4- 5dB (TX/RX) Beamflex gain. 12. Device should support 10 dB interference rejection 13. Device must support -103 dBm Receive Sensitivity. 14. Transmit power of AP’s: 26 dBm on 2.4 GHz and 25 dBm on 5 GHz Radio. 15. Support automatic RF Channel selection. 16. Access Point should support Space time Block coding (STBC), Low Density Parity Check (LDPC), Maximum Likelihood Decoding (MLD) for Batter Downlink and Uplink Transmission. 17. AP should support 802.3af POE standards. 18. AP must have 2 x Auto MDX, Auto Sensing Gigabit Ethernet Port. 19. AP should have USB Port for IoT technologies. 20. AP should support Ethernet 802.1x port-based authentication. 21. Wireless Security: WEP, WPA-PSK, WPA-TKIP, WPA2 AES, 820.11i 22. Support integrated NAT and DHCP as Standalone Access Point. 23. The access point should support 802.1q VLAN tagging 24. Implement Wi-Fi alliance standards WMM, WMM-PS, 802.11d, 802.11h and 802.11e. 25. Support advance QoS Packet Classification and automatic priority for latency- sensitive traffic. 26. Support up to 30 VO-IP clients. 27. 500 Concurrent clients support. 28. AP should support IP multicast video streaming.

03 PoE Injectors PoE injectors which support above mentioned WAPs to operate 14

Note: Bidder must provide Warranty & Support of hardware equipment for atleast 1 year

PASSIVE MATERIAL

01 UTP Cable Cat-6

Cat 6 UTP, 23AWG 4Pair Cable Roll (305 Meter) Mechanical Characteristics Conductor: Solid Bare Copper AWG: 23 Conductor Dia Norm: 0.574 Insulation: PE Average Thickness (±0.03mm): 0.23 Min. Point Thickness (mm): 0.18 Insulation Dia. (±0.05mm): 1.04 Twisting Lay Length (mm): 30underneath Cabling Lay Length (±10mm): 140 Filler: PE Jacket: PVC Average Thickness (±0.05mm): 0.50 Min. Point Thickness (mm): 0.46 Outer Dia. (±0.15mm): . NVP (%): 68 6.20 Weight (kg/km): 14 Electrical Characteristics UL Listed

Approx1830 M / As per Actual

02 Fiber cable 12 core Single Mode optical fiber G652D, Maximum 12 fibers per tube and solid polyethylene fillers, reinforced plastic (FRP) central strength member, water blocked interstices, taped, polyethylene inner sheathed, corrugated steel tape

Approx. 600 M /As per

Page 12: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

12

armored, polyethylene overall sheathed. Sheath Thickness: 2.2mm average, Operating Temperature:-40°C to +70°C, Storage Temperature:-40°C to +70°C.Electrical/Optical Characteristics: Tensile Strength.

actual *

03 24 port Patch Panel

Material: CRS (cold rolled steel), Thickness: .060” (1.52mm), Coating: Graphite Grey Powdercoat. Dimensions: 44mm H x 483mm W x 98mm D, Interface Resistance: 20 mΩ, Initial Contact Resistance: 2.5 mΩ, Insulation Resistance: >100 MΩ, Plastic Housing: Polycarbonate, UL94V-0 rated or Equivalent, Operating Life: Minimum 750 insertion cycles, Contact Material: Copper Alloy, Contact Plating: 1.27 micrometres Au/Ni, Contact Force: 100g minimum, Plug Retention Force: 15 lbs, IDC Connector: Plastic Housing: Polycarbonate, UL94V-0 rated or Equivalent, Operating Life: Minimum 200 Reterminations, Contact Material: Copper Alloy, IDC Contact Plating: Tin matte finish, Contact Force: 100g minimum, Wire Accommodation: 22-24 AWG solid.

4

04 Multi-mode Patch Cord SC-LC

Cordage O.D.: 2.0mm +/- 0.1mm x 4.1mm +/- 0.2mm, Buffer Diameter: 900μm, Primary Coating: 245μm, Strength Member: Aramid Yarn, Jacket Material: LS0H IEC 61034-1 & 2, IEC-60332-1, IEC-60754- 1 & 2, Minimum Bend Radius: Install: 3.0cm., Long Term Bend Radius: 2.0cm, Operating Temperature: -40°C to +85°C. Color: Orange

15

05 Cat 6 Patch Cord

Conductor size: 26 AWG stranded copper wire, Screen material: Aluminum/polyester shield with tinned copper drain wire, Nom. O.D.: 6.5mm, Sheath: Low Smoke Zero Halogen (LS0H), Bend radius: 8X O.D., Operating temperature range: -20°C to 60°C. MIN operating life: 750 insertion cycles, RJ45 plug material: Clear polycarbonate (PC), Boot material: Clear, polyvinylchloride (PVC), Contact material: 0.35mm thick copper, Contact plating: 1.27um gold, RJ45 plug dimensions compliant with: ISO/IEC 60603-7 and FCC 47 Part 68. Max voltage: 150 VAC (max), Max current: 1.5A @ 25°C

40 Cables of 1 M + 20 Cables of 3M length

06 24 port Cable Management Panel

Panel Material: Cold Rolled Steel, Thickness: 1.5mm (.06”), Finish: Graphite Grey Powdercoat/ Option for Black, Material: Thermoplastic UL94V-0, Cover Material: Graphite Grey, Extruded UV Grade Rigid PVC. Size: 1U

4

07 Multi-Function Fiber Enclosure

Material: Powder Coated Mild Steel, Fibre Termination Options: Direct, Fusion Splice, Mechanical Splice, Pre-Terminated MTP Dimensions: 482mm W x 270mm D x 43mm H Shipping Weight: 3.84Kg.

4

08 Pig Tails SC Pigtails 6 PC X 1 Fibre 50μm (OM3) MM - 1.5M 12

09 Wall Plates Single Shutter with CAT6

Single Face Plates shutter with Cat 6 RJ45. 15

Page 13: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

13

RJ45 Keystone Jack

10 In Wall Boxes Color White 15

11 12 U Data cabinet

Double Section 600x600, 1 Fixed tray, 2 Fans, Wall mounting, glass door and powder coated

3

12 Misc. Materials & Services

Ethernet CAT 6 Cable laying Services Including material i.e. Duct, PVC Pipe Jeddah/Adamjee/Master , Multiple Size According to requirement, Best Quality)etc. in Ft. (Chiseling, Digging, Carpenting and mason work not included)

01

Page 14: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

14

Annex ‘B’

(Bid Form)

LOT 1 Sr. No Item Qty. Unit Rate

(Including all

taxes)

Total Prices

(Including all

taxes)

01 24 Port Layer 2 Switch 03

02 28 Port PoE+ Switch 01

03 SFP Modules 08

Total_________________________

Total in words:_________________________________________________________________

Page 15: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

15

Annex ‘B’

(Bid Form)

LOT 2

Sr. No Item Qty. Unit Rate

(Including all

taxes)

Total Prices

(Including all

taxes)

01 WLAN Controller 01

02 Wireless Access Points 18

03 UTP Cable Cat-6 1830M

04 Fiber cable 600 M

05 24 port Patch Panel 04

06 Multi-mode Patch Cord SC-LC

15

07 Cat 6 Patch Cord 40+20

08 24 port Cable Management Panel

4

09 Multi-Function Fiber Enclosure

4

10 Pig Tails 12

11 Wall Plates Single Shutter with CAT6 RJ45 Keystone Jack

15

12 In Wall Boxes 15

13 12 U Data cabinet 3

14 Misc. Materials & Services

01

15 PoE Injectors 14

Total_________________________

Total in words:_________________________________________________________________

Page 16: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

16

Annex ‘C’

Company Evaluation Criteria

1. Basic Evaluation

i. Profile of company

ii. Detail of Previous/Current customers of related Supplies, Purchase Orders, with contact

person and telephone/cell numbers.

iii. Detailed product information

iv. Copy of National Tax Registration Certificate

v. Copy of Sales Tax Registration Certificate

vi. Bank letter/Certificate of Account Information/financial standing

vii. An affidavit on Rs. 100/- Stamp Paper that currently they are not black listed or de- barred

by any Government/Semi-Government Department to participate in bidding and to supply

equipment. Failure to submit such affidavit may lead to disqualification.

viii. Detailed item specifications matched corresponding to the BOQ as given at Annex ‘A’

ix. Detailed project implementation schedule/Completion Schedule which includes the

delivery of items mentioned in the BOQ

x. Signed and stamped Tender document

Page 17: Fatima Jinnah Medical University Lahore · 3 1. Overview Fatima Jinnah Medical University, ... to USB Type C port, File Transfer USB Port. 3. Switch should support 132Gbps Capacity

17

2. Detailed Evaluation

(Minimum Passing Score Required is 70 Points)

TECHNICAL EVALUATION CRITERIA FOR TENDER

Specifications are available at Annex-A

Sr. No Item Name and Description Marks Max Marks

1 Past Performance/Experience of the Bidder (Reg. with

-- 10 GST/NTN)

1.1 1 – 3 year experience 2 --

1.2 4 – 8 year experience 4 --

1.3 9 – 15 years’ experience 6 --

1.4 Above 15 10 --

2 Relevant Experience -- 10

2.1 1 – 5 years’ experience 3 --

2.2 6 – 10 years’ experience 6 --

2.3 The bidder will Provide details of 03 operational offices in Pakistan 10 --

3 Financial Position/ Status -- 10

3.1 Last sales tax paid Form 4 --

3.2 Bank Certificate (satisfactory) 2 --

3.3 Statement Worth (Min 2 m) 4 --

4 After Sale Services Available -- 10

5 Technical Evaluation of quoted items -- 60

5.1 Specification matched as provided in Annex-A 30

5.2 Literature in printed shape attached 2.5

5.3 Reliability 2.5

5.4 Bidder will submit relevant certification of atleast 05 10

Resources of quoted brand

5.5 Satisfactory letter from clients in favour of such equipment 5

5.6 Guarantee / Warranty (as the case may be) 5

5.7 Provision of Training to concerned user 2.5

5.8 Free Installation (if required) as per requirement 2.5

Total -- 100

REGISTRAR

FATIMA JINNAH MEDICAL UNIVERSITY, LAHORE