fast training program

27
FAST TRAINING PROGRAM ( SOLIDVIEW VERSION 4.XX TUTORIAL ) August 8, 2020 Matt Ramon

Upload: others

Post on 17-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FAST TRAINING PROGRAM

FAST TRAINING PROGRAM(SOLIDVIEW VERSION 4.XX TUTORIAL)

August 8, 2020Matt Ramon

Page 2: FAST TRAINING PROGRAM

TABLE OF CONTENTS

➢ USER INTERFACE

➢ TROUBLESHOOTING

➢ QUIZ

➢ CONLUSION

Page 3: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User login interface

➢ User1 : w

o Password: w

➢ User2 : service1

o Password: #Service1

Page 4: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User1: w

• Three(4) tabs

1) Logout

2) Operations

3) Event Log

4) Layout Configuration

1 2

3

Page 5: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: w and service1

• Three(4) tabs

1) Operations

➢ Find Trailer

➢ Monitor Info

➢ Sorting Templates

o Normal

o Holidays

o Back To School

➢ Info:

o Selected Trailer,

o Outs Quantity,

o Event Log,

o Layout Configuration

1

5

3

6

4

2

7

Page 6: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: w and service1

• Three(4) tabs

2) Event Log

➢ Time

➢ Barcodes

➢ Walmart Info

o Description

o Sort Lane

➢ Casi

o Confirm Lane

o Additional Info

1 2 3 4 5 6

Page 7: FAST TRAINING PROGRAM

Field Definition

Time The system time of the scan

Barcode The Barcode number on the box

Description DLL reopen and describe what to do with the box

Sort Lane The Lane tie the system

Confirm Lane Verification that the box in the event was sorted to the correct lane

Additional Info Display special sorting instructions

USER INTERFACE (VERSION 4.XX)

The following information

is available on the Event Log Tab:

This is an auto-refreshing

and will scroll up

unless you disable the auto-refresh.

1 2 3 4 5 6

Page 8: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: w and service1

• Three(4) tabs

3) Layout Configuration

➢ Layout Configuration

With 4 sorters

➢ Layout Configuration

With 2 sorters

Page 9: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: service1

• Six(7) tabs

1) Logout

2) Operations

3) Event Log

4) Layout Configuration

5) System Logs

6) PLC Network

7) System

Page 10: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: service1

• Six(7) tabs

4) System Logs

➢ Table Info:

o LogDate

o LogMessage

➢ Heartbeat Info:

o From PLC

o To PLC

o Missed heartbeats

Have to be identical

Page 11: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: service1

• Six(7) tabs

5) PLC Network

➢ IP Subnet Down Stream (Halo to Lane 9): 192.168.1.20-41

➢ IP Subnet UP Stream (Halo to Aflex ELM): 192.168.2.20-31

Page 12: FAST TRAINING PROGRAM

USER INTERFACE (VERSION 4.XX)• User: service1

• Six(7) tabs

6) System

➢ Settings and Troubleshooting

➢ Services

o SolidCommWm

o SolidRead (PLC)

o SolidSettingSVC

o SolidWrite (PLC)

Page 13: FAST TRAINING PROGRAM

THE SYSTEM IS RUNNING !!!

Page 14: FAST TRAINING PROGRAM

TROUBLESHOOTING

The system runs correctly when:

➢ In the “Operation” tab, the version of the application is correct.

➢ All sorters in the “PLC Network” tab are defined and matched the correct sorter

name for the version being pushed.

➢ On the “System” tab, the “Store Number” is correct, the “Environment” is set

to “Prod”, all services are green, and the application version is correct.

Page 15: FAST TRAINING PROGRAM

TROUBLESHOOTING

1) In the “Operation”

tab the version of

the application is

correct.

Page 16: FAST TRAINING PROGRAM

TROUBLESHOOTING

2) All sorters in the

“PLC Network” tab

are defined and

matching the

correct sorter name

for the version

being pushed.

Page 17: FAST TRAINING PROGRAM

TROUBLESHOOTING3) On the “System” tab

the “Store Number” is correct,

the “Environment” is set to “Prod”,

all services are green,

and the application version is correct.

Note:

a) SolidRead and SolidWrite are related

to the PLC. Any issues from should be

resolved through the PLC.

b) Any changes made in this tab should be saved first,

then the user needs to exit and to reopen SolidView

Page 18: FAST TRAINING PROGRAM

WEBVISUALIZATION (WEBVISU)

➢ Webvisu is a web application that helps to visualize and to control the whole system.

The user will have the ability to monitor the system using the features(buttons)

providing by the application.

➢ Webvisu facilitates the testing and the troubleshooting of the system. With webvizu, the

user can easily detect the problem, and proceed to the resolution of the issue.

Page 19: FAST TRAINING PROGRAM

WEBVISUALIZATION (WEBVISU)1. Press the CASI logo

to minimize the

SolidView Window

Page 20: FAST TRAINING PROGRAM

WEBVISUALIZATION (WEBVISU)

Accessing Webvisu

1. Go to the Windows task bar

and select Internet Explore (IE)

2. IE will launch with this screen

3. Select Main

Page 21: FAST TRAINING PROGRAM

WEBVISUALIZATION (WEBVISU)

1. Select “Hide All Man”

the “Green” indicator

will turn off

2. You will see this screen

3. You can then select

manual operation of

zones, 101e, flag

sensors.

Page 22: FAST TRAINING PROGRAM

QUIZ !!!

Page 23: FAST TRAINING PROGRAM

FAST TRAINING (VERSION 4.XX)Can you tell me who logged in based on the images below?

Page 24: FAST TRAINING PROGRAM

FAST TRAINING (VERSION 4.XX)

Can you tell me who logged in based on the images below?

Answer: w Answer: service1

Page 25: FAST TRAINING PROGRAM

FAST TRAINING (VERSION 4.XX)

Can you tell me which system is working or not?

Page 26: FAST TRAINING PROGRAM

FAST TRAINING (VERSION 4.XX)

Can you tell me which system is working or not?

Answer: This system is not working. Answer: This system is working.

Page 27: FAST TRAINING PROGRAM

CONCLUSION

• THE UI

➢ “w” has three(4) tabs

1) Operations

2) Event Log

3) Layout Configuration

➢ “service1” has six(7) tabs

1) Operations

2) Event Log

3) Layout Configuration

4) System Logs

5) PLC Network

6) System

• Troubleshooting

➢ Make sure the version of the application is correct in the

“Operation” tab

➢ Verify All sorters IP Addresses are in sequence and match

in the “PLC Network”

➢ Check the “Store Number”, the “Environment”, and all

services in the “System” Tab