CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TOPREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.WARNING: Before installing or maintaining the luminary, make sure all powers areTURNED OFF.Verify that supply voltage is correct by comparing it with the label information on allfixtures.Make all connections in accordance with the NEC requirements, and make sure allluminaries are properly secured to prevent any wire complications. This luminary isto always be installed with the lens facing down and its not to exceed the maximumambient temperature rating noted on the specification sheet.
FALB Series LED Area Light Installation Sheet
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2017 PacLights All Rights Reserved
LED DRIVER
V(-)
[BLACK]
V(+)
[RED]
TO LOAD
[LED BOARD][WHITE]
[BLACK]ACN [BLUE/WHITE]
ACL [BROWN/BLACK]
GROUND [GREEN]
NEUTRAL [WHITE]
GROUND [GREEN]
HOT [BLACK]
INP
UT
OU
TP
UT
DIM
WH
ITE
(-)
BL
UE
(+)Inside F2SB
PRE-CONNECTED
(DO NOT DISCONNECT)
Using a J-Box (not included), Connect the ACL and the ACN from the driver to the conduit with the AC Power Supply cords.Follow the Wiring Diagram provided.
* LED DRIVER Input Ground (green) wire only available for selected fixtures.
If the Ground Wire is missing and the Power Supply includes a ground wire, connect the power supply ground wire to the fixture.
(FOR DIMMABLE VERSION)
7. Adjust the Tilt Angle on the F2SBluminaire, once the Tilt Angle is asdesired, finish tightening the SocketHead bolt to firmly tighten the F2SB withthe Arm Mount.
Note: Instructions are subject to change at any time without notice
STANDARD INSTALLATION STEPS
DRILLING TEMPLATE
5.5
0 in
4.2
5 in
3.6875 in
.625 in
2. Place mount against round tube.
3. Install the provided [2] Socket headM8-1.25 x 40 mm bolts with lock washerand washer to secure the arm mountfirmly in place, insert the flat-barwith threaded holes inside theround tube and use thethreaded holes to securethe mount. Make sure allbolts are tightened andholes are properly sealed.
1. Use provided Hole Pattern for drilling. Make sure to makean extra notch for the power cables to run through the RoundTube.
4. Once the Arm Mount is properlyfastened to the mounting round pole, runthe power cord cable from the inside ofthe pole and out the notch from the Arm Mount. This cablewill then be inserted intothe F2SB fixture.
5. Run the power cord from thearm mount to the F2SB luminaire,Once the cable has been insertedinside the F2SB, connect the powercable to the LED Driver inside theF2SB. In order to access the LEDDriver cables, the electrician mustfirst remove the [6] screws from the service door using a #2 Phillipsscrew driver and make allconnections inside the luminaire.
6. Once all wiring is complete,Close the service door and usethe M12 bolt to fasten theArm Mount to the F2SB.Do not fasten completely.
02-00002-103117-2
AC-ALB-AM Arm Mount (Round or Square Pole)Includes:FALB080, FALB100, FALB120, FALB150, FALB185, FALB240, FALB300
AC-ALB-AM can be used on a Round Pole or a Square Pole
DRILLINGTEMPLATE
O 0.688” RunPower SupplyCable throughthis holeopening intothe Arm Mount
1
4. Fasten the small bracket to the FALB fixture withthe provided socket head machine screws,lock-washers, and washers.
WIRING DIAGRAM
The LED Driver input cable consists of 3 conductors:ACL (black), ACN (white), and ground (green). These conductors are to be connected to a PowerSupply Cable.
(For Dimmable Fixtures) The Dimming cableconsists of 2 conductors:DIM+ (Blue/ Brown+Gray)DIM- (White/ Blue+ Black)
FALB
DIM+ (BLUE)
DIM- (WHITE)
AC-ALB-AMbracket
Socket HeadMachine Screw
Lock-washer
Washer
Square PoleGasket
Round Pole adapter plate
Round Pole Gasket
Locking Plate
5.531”
6.313”
O 0.375”Clearance holeson pole to alignwith Lockingplate holelocations
2.00”
FALB
DIM+ (BLUE)
DIM- (WHITE)
WIRING DIAGRAMThe LED Driver input cable consists of 3 conductors:ACL (black), ACN (white), and ground (green).These conductors are to be connected to a Power Supply Cable.
(For Dimmable Fixtures)The Dimming cable consists of 2 conductors:DIM+ (Blue/ Brown+Gray) & DIM- (White/ Blue+ Black)
1. Drill holes on the square pole by followingthe Drilling Templateto mount the FALB tothe desired heigh.
2. Remove the Locking Plate from the ArmMount by removing the Socket headmachine screws and
3. (Optional) If the FALB fixture is beinginstalled to a round pole. Skip this step.Otherwise, Remove the Flat-headmachine screws and remove the roundpole adapter plate with it’s gasket.
4. Using a Phillips Screwdriver,remove the [4] Flat-head machinescrews before installing into theFALB fixture.
5. Align the holes from the AC-ALB-AM armmount with the FALB fixture and use theprovided Socket head machine screws withwashers to fasten them together. Run theFALB cables through the nylon gasket insidethe arm mount.
6. Place the lock plate insidethe mounting pole and fastenthe FALB fixture onto the polewith the socket head machinescrews removed in Step 2.
7. Run the Power Supply cable inside the mount polethrough the 3/8” clearance hole and into theAC-ALB-AM. Follow the Wiring Diagram to properlyconnect the FALB fixture.
6b. (optional)If this is being installed to aRound Pole. All steps must befollowed same as a squarepole, except the round poleadapter will still be attached tothe AC-ALB-AM bracket.
8. All wiring mustbe installed by acertified electricianand must becompliant to NECstandards. Once allwiring is properlyinstalled Fasten thecap back to theAC-ALB-AM armmount.