facial detection and temperature measurement · 2020. 6. 19. · temperature measurement solution...
TRANSCRIPT
An advanced facial detection system that works in conjunction with Biosite access control to safely and efficiently monitor operative temperature on site.
www.biositesystems.com
Facial detection and temperature measurement
WorkforceManagement
Workforce Management / Facial detection and temperature measurement
Effective temperature management on site
Features and benefits
To minimise the transmission of and exposure to infectious diseases on site, regular operative temperature monitoring is recommended. The facial detection system from Biosite is an efficient temperature measurement solution utilising innovative in-vivo detection technology that is 99.8% accurate.
The unit can be installed at entrance and exit points on site to monitor operative temperature
during throughput via forehead readings, meaning operatives can maintain wearing face masks. The system quickly and accurately calculates a temperature reading within 0.3℃ and in less than one second. Putting you in control of operative temperature management on site.
Infrared thermometer and face detection machine Works in conjunction with Biosite card reader or biometric access control system. Monocular in-vivo technology is safe and more efficient than alternative detection technology Delivers an accuracy rate of 99.8% Clearly displays operative temperature on screen Highly visible ‘please wear your mask’ reminder message
Industrial chip platform and system, using a high stability Hayes chip and mini version Linux systemLow power consumption (as low as 4W) Support for temperature interface protocol Multi-scene image exposure and correction algorithm
•
•
•
•••
•
•••
www.biositesystems.com
How does the solution work?
Additional information
Temperature measuring equipment should be used in rooms between room temperature -10℃ to 30℃
For accurate readings, the forehead should be left unobstructed (free of hair or clothing)
Outdoor temperatures can affect the accuracy of readings – if an operative enters from a cold outdoor environment, wait a minute for
their temperature to stabilise before taking a temperature test
Marks or coverage on the forehead area, including wrinkles, oil stains, water, sweat or heavy make-up can impact the accuracy of the temperature reading
Operative temperature and snapshot taken by
the Dual band IR Camera fixed on the turnstile
Proceed with fingerprint/card reader
Email including photo and temperature of
the operative sent to a designated email address
Temperature within normal range?
YES
YES
NO
NO
Normal entry requirement met?
Entry granted
Entry denied
www.biositesystems.com
T / 0121 374 2939E / [email protected]
Biosite Systems Ltd. Lancaster House, Drayton Road, Solihull, B90 4NG
Technical parameters
Conventional parameters
Temperature measurement module parameters
Operating system (OS) Embedded Linux
7” HD IPS Display
<0.5 second (30,000 base)
<0.5 second (30,000 base)
< 1m
DDR3 8GB
200W pixel ,120 degree wide angle lens, support wide dynamic, white night vision
99.8%
99.8%
0.5-0.8m
Maximum support 50,000
Maximum support 50,000
-10-30℃
5.5-14um
Standard 8 built-in GB,128 GB extended with TF card
Support for face detection
Face detection supports a minimum face pupil distance of 20 pixels
Face recognition supports a minimum face pupil distance of 20 pixels
±0.3℃
Support
Support
0.97±0.02
< 1s
Display screen
To
Network
Temp. measurement distance
Optimum distance
Indoor temp. measurement accuracy
Temp. measurement working environment
Effective emmissivity
Wavelength size
Corresponding time
Internal storage
Monocular camera
Face detection rate
Communication mode
Storage capacity
Installation characteristics
SC
Opening the door
Minimum pixel
Supply electricity
Black & White list function
Custom services
Technical data