Page 1: Fabrication Process PDMS Electrode Array

Fabrication Process PDMS Electrode

Array

ME342 MEMS Laboratory

Jennifer Blundo

Gretchen Chua

Yong-Lae Park

Ali Rastegar

Page 2: Fabrication Process PDMS Electrode Array

Project Goal

• Design a bioMEMs substrate to apply and

measure electromechanical forces in the

differentiation of human embryonic stem cell-

derived (hESC)-cardiac myocytes (CM)

Undifferentiated hESCs-Fluc-eGFP

(DAPI nuclear stain)

hESC-CMs organized in embryoid body

bioMEMS device

Contractility

Electrophysiology

Mechanical force

Page 3: Fabrication Process PDMS Electrode Array

Current Microscale Devices

Thin-film stretchable (0—15%) gold electrodes (25nm) on PDMS. Lacour et al, 2005.

Thin-film gold strain gauges (200nm) encapsulated in PDMS (50μm). Wen et al, 2005.

64 Electrode array for extracellular recording, Multi Channel Systems

Pressure actuated PDMS membrane (120μm) with S-shaped SiO2 traces. Lee et al, 2004.

Page 4: Fabrication Process PDMS Electrode Array

BioMEMS: Engineering Specs

Device Requirement Target Value

1. Apply mechanical strain Up to 10%

2. Apply electric field ~O(1) V/cm

3. Measure electric potential (ECG) 100μV—1mV

4. Area of mechanical deformation A < 1cm2

5. Size of electrodes diameter = 20μm

6. Inter-electrode spacing spacing = 250μm

7. Area of cell culture A > 1cm2

8. Thickness of substrate t < 1mm

Page 5: Fabrication Process PDMS Electrode Array

BioMEMS: Device Design

A. Unstrained state B. Strained state

Glass/Quartz: Optically transparent baseplate PDMS: A biocompatible elastomeric polymer

PPS: A biocompatible elastomeric polymer

Ti: Adhesion layer for electrodes

Gold: Biocompatible thin film electrodes

SU-8: Transparent polymer

Page 6: Fabrication Process PDMS Electrode Array

Fabrication: Baseplate

Step 1: Clean Pyrex 7740 4” glass wafer (300μm thick), dehydrate

5min @ 200°C

Equipment: Acetone/Methanol/IPA/DI rinse Location: MERL

Glass

Page 7: Fabrication Process PDMS Electrode Array

Fabrication: SU-8 Processing

Glass

Channels to apply vacuum pressure to PDMS membraneGlass

Exposed SU-8

Unexposed SU-8

Step 2: Spin 1st layer SU-8-100 (100μm thick), prebake 10min @

65°C, softbake 30min @ 95°C, expose, postbake 1min @ 65°C,

10 min @ 95°C

Equipment: Spin coater, hot plate, UV Location: MERL

Page 8: Fabrication Process PDMS Electrode Array

Fabrication: SU-8 Processing

Step 3: Spin 2nd layer SU-8 (100μm thick), prebake, expose,

postbake

Equipment: Spin coater, hot plate, UV Location: MERL

Loading post to support PDMS membrane

Glass

Exposed SU-8

Unexposed SU-8

Page 9: Fabrication Process PDMS Electrode Array

Fabrication: SU-8 Processing

Step 4: Spin 3rd layer SU-8 (100μm thick), prebake, expose,

postbake

Equipment: Spin coater, hot plate, UV Location: MERL

Glass

Exposed SU-8

Unexposed SU-8

Page 10: Fabrication Process PDMS Electrode Array

Fabrication: SU-8 Processing

Step 5: Spin 4th layer SU-8 (80μm thick), prebake, expose,

postbake

Equipment: Spin coater, hot plate, UV Location: MERL

Glass

Exposed SU-8

Unexposed SU-8

Page 11: Fabrication Process PDMS Electrode Array

Fabrication: SU-8 Processing

Step 6: Develop SU-8, IPA/DI rinse

Equipment: Location: MERL

Glass

Exposed SU-8

Page 12: Fabrication Process PDMS Electrode Array

Fabrication: SU-8 Processing

Step 7: Pipette tetrafluoropolymer (PS200 or T2494) to prevent

PDMS membrane stiction

Equipment: Location: MERL

Glass

Exposed SU-8

Tetrafluoropolymer

Page 13: Fabrication Process PDMS Electrode Array

Fabrication: Baseplate Assembly

Step 8: Laser cut quartz 4” wafer (300μm thick) and bond quartz

over SU-8

Equipment: Laser cutter Location: MERL

Glass/Quartz

Exposed SU-8

20μm clearance between loading post and PDMS membrane

Page 14: Fabrication Process PDMS Electrode Array

Process Option 1—Top to Bottom

Photoresist

PDMS Electrode Array

Page 15: Fabrication Process PDMS Electrode Array

Fabrication: PDMS Membrane

Step 1: Clean 4” silicon wafers

Equipment: wbdiff Location: SNF

Silicon

Page 16: Fabrication Process PDMS Electrode Array

Fabrication: PDMS Membrane

Step 2: Spin sacrificial layer 5% (w/v) poly(acrylic acid) (PAA)

(3000 rpm, 15 s) and bake (150C, 2 min)

Equipment: Spin coater, Hot plate Location: MERL

Silicon

PAA

¼” Kapton tape at edge, removed after bake to prevent lift-off of PDMS during processing

Page 17: Fabrication Process PDMS Electrode Array

• Advantages of water-soluble films – Deposited by spin-coating– The solvent removed at a low temperature (95–150C)– The resulting layer can be dissolved in water– No corrosive reagents or organic solvents– Faster release of features by lift-off

• Compatible with a number of fragile materials, such as organic polymers, metal oxides and metals—materials that might be damaged during typical surface micromachining processes

Sacrificial Layers—PDMS Micromachining

Page 18: Fabrication Process PDMS Electrode Array

Sacrificial Layers—PAA & Dextran

Page 19: Fabrication Process PDMS Electrode Array

BioMEMS: Fabrication

Step 3: Spin thick photo resist ~ 10μm

Equipment: SVGcoat Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 20: Fabrication Process PDMS Electrode Array

BioMEMS: Fabrication

Step 4: Expose, develop, postbake

Equipment: KarlSuss, SVGdev Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

20μm diameter electrodes

200μm interelectrode distance

Page 21: Fabrication Process PDMS Electrode Array

BioMEMS: Fabrication

Step 5: Gold deposition (2μm thick)

Equipment: Metallica Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 22: Fabrication Process PDMS Electrode Array

BioMEMS: Fabrication

Step 6: Resist strip

Equipment: Wbgeneral2 Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 23: Fabrication Process PDMS Electrode Array

BioMEMS: Fabrication

Step 7: Spin photo-patternable silicone (PPS) WL5153 30sec @

2500rpm (6μm thick), prebake 110°C

Equipment: Headway Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 24: Fabrication Process PDMS Electrode Array

BioMEMS: Fabrication

Step 8: Expose*, postbake @ 150°C**, develop, hardbake 150°C

Equipment: Metallica Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 25: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 9: O2 plasma (several min)* to etch and round PPS as well as

promote adhesion of metal deposition

Equipment: Gasonics

Silicon

PAA

PDMS

Shadow Mask

Ti

Au *Requires characterization

PPS

Page 26: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 10: Align beryllium copper shadow mask and temporarily

bond.

Equipment: EV aligner Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 27: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 11: Evaporate Ti adhesion layer (10nm thick), Au layer

(100nm thick), Ti adhesion layer (10nm thick)

Equipment: Innotec Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

30μm diameter to allow 20μm diameter electrodes

30μm width horseshoe tracks for electrode connections

Maintain 200μm interelectrode distance

Page 28: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 12: Remove shadow mask, O2 plasma to clean and promote

adhesion

Equipment: Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 29: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 13: Spin 20:1 Sylgard 184 poly(dimethylsiloxane) (PDMS)

90sec @ 1200 rpm (50μm thick), bake (60°C, 1 hr)

Equipment: Location: MERL

Silicon

PAA

PPS

Ti

Au

PDMS

Page 30: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 14: Dissolve sacrificial layer PAA in water

Equipment: wbgeneral Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

PPS

Page 31: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 15: Air dry device and transfer with handle wafer (glass)

Equipment: N2 gun Location: SNF

PPS

PDMS

Ti

Au

Glass

Page 32: Fabrication Process PDMS Electrode Array

Fabrication: Assembly

Step 16: O2 plasma PDMS and quartz surfaces

Equipment: Drytek

PDMS

PPS

Ti

Au

Glass/Quartz

SU-8

Page 33: Fabrication Process PDMS Electrode Array

Fabrication: Assembly

Step 2: Bond PDMS membrane to glass

Glass/Quartz PDMS

PPS

Ti

Au

SU-8

Page 34: Fabrication Process PDMS Electrode Array

Process Option 2—Top to Bottom

Skip Photoresist—Pattern PPS right

on PAA, expose, deposit metal

PDMS Electrode Array

Page 35: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 4: Spin photo-patternable silicone (PPS) WL5153 30sec @

2500rpm (6μm thick), prebake 110°C, expose*, postbake @

150°C**, develop, hardbake 150°C

Equipment: Hot plate, Spin coater, Karl Suss*, BlueM oven**,

wbgeneral

Silicon

PAA

PDMS

Shadow Mask

Ti

Au *Proximity exposure

**Need to characterize in BlueM Oven

PPS

Page 36: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 5: O2 plasma (5 min)* to etch and round PPS

Equipment: Gasonics

Silicon

PAA

PDMS

Shadow Mask

Ti

Au *Requires characterization

PPS

Page 37: Fabrication Process PDMS Electrode Array

Process Option 3—Bottom to Top

Pattern PDMS right on PAA, deposit

metal, spin PPS, expose, O2 plasma

etch down OR HCl dip if use Ti layer

PDMS Electrode Array

Page 38: Fabrication Process PDMS Electrode Array

Fabrication: PDMS Membrane

Step 1: Clean 4” silicon wafers

Equipment: wbdiff Location: SNF

Silicon

Page 39: Fabrication Process PDMS Electrode Array

Fabrication: PDMS Membrane

Step 2: Spin sacrificial layer 5% (w/v) poly(acrylic acid) (PAA)

(3000 rpm, 15 s) and bake (150C, 2 min)

Equipment: Spin coater, Hot plate Location: MERL

Silicon

PAA

¼” Kapton tape at edge, removed after bake to prevent lift-off of PDMS during processing

Page 40: Fabrication Process PDMS Electrode Array

Fabrication: PDMS Membrane

Step 3: Spin 20:1 Sylgard 184 poly(dimethylsiloxane) (PDMS)

(50μm thick), bake (60C, 1 hr), O2 plasma (1 min)

Equipment: Location: MERL

Silicon

PAA

PDMS

2mm gap at edge of wafer to prevent lift-off of PDMS during processing

Page 41: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 4: Align beryllium copper shadow mask and temporarily

bond.

Equipment: EV aligner Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

30μm diameter to allow 20μm diameter electrodes

30μm width tracks for electrode connections

200μm interelectrode distance

Page 42: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 5: Evaporate Ti adhesion layer (10nm thick) and Au layer

(100nm thick)*

Equipment: Innotec Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

30μm diameter to allow 20μm diameter electrodes

30μm width tracks for electrode connections

*May want second layer of Ti to promote adhesion to PPS on top layer! Use an HCl dip to dissolve this

Page 43: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 6: Remove shadow mask, O2 plasma

Equipment: Drytek Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

Page 44: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 7: Spin photo-patternable silicone (PPS) WL5153 30sec @

2500rpm (6μm thick), prebake 110°C, expose*, postbake @

150°C**, develop, hardbake 150°C

Equipment: Hot plate, Spin coater, Karl Suss*, BlueM oven**,

wbgeneral

Silicon

PAA

PDMS

Shadow Mask

Ti

Au *Proximity exposure

**Need to characterize in BlueM Oven

PPS

Page 45: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 8: O2 plasma (5 min)* to etch and round PPS as well as

promote adhesio

Equipment: Gasonics

Silicon

PAA

PDMS

Ti

Au

PPS *Requires characterization

PPS

Page 46: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 9: Dissolve sacrificial layer PAA in water

Equipment: wbgeneral Location: SNF

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

PPS

Page 47: Fabrication Process PDMS Electrode Array

Fabrication: Electrode Array

Step 10: Air dry device and transfer with handle wafer (glass)

Equipment: N2 gun

Silicon

PAA

PDMS

Shadow Mask

Ti

Au

PPS

Page 48: Fabrication Process PDMS Electrode Array

Fabrication: Assembly

Step 1: O2 plasma PDMS and quartz surfaces

Equipment: Drytek

Silicon

PDMS

PPS

Ti

Au

Glass/Quartz

SU-8

Page 49: Fabrication Process PDMS Electrode Array

Fabrication: Assembly

Step 2: Bond PDMS membrane to glass

Glass/Quartz PDMS

PPS

Ti

Au

SU-8

Page 50: Fabrication Process PDMS Electrode Array

Process Option 4—Entire Device

Pattern PDMS right on top of

baseplate with PAA sacrifical layer,

follow process option 3

PDMS Electrode Array

Page 51: Fabrication Process PDMS Electrode Array

Fabrication: PDMS Membrane

Step 1: Fill baseplate with sacrificial layer—5% (w/v)

poly(acrylic acid) (PAA). Spin, squeegy off, bake (150C, 2

min). O2 plasma (1 min)

Equipment: Spinner Location: MERL

Glass/Quartz

Exposed SU-8

20μm clearance between loading post and PDMS membrane

Page 52: Fabrication Process PDMS Electrode Array

Step 2: Spin 20:1 Sylgard 184 poly(dimethylsiloxane) (PDMS)

(50μm thick), bake (60C, 1 hr), O2 plasma (1 min)

Equipment: Spinner, oven Location: MERL

Glass/Quartz

Exposed SU-8

20μm clearance between loading post and PDMS membrane

Fabrication: PDMS Membrane

Page 53: Fabrication Process PDMS Electrode Array

Final Device: Deposit metal, spin PPS, expose, O2 etch

Glass/Quartz

Exposed SU-8

Fabrication: PDMS Membrane

Page 54: Fabrication Process PDMS Electrode Array

Final Device: Dissolve PAA

Glass/Quartz

Exposed SU-8

Fabrication: PDMS Membrane

Page 55: Fabrication Process PDMS Electrode Array

The Meander Evolution…

Challenge: To maintain electrical

connections under strain

Page 56: Fabrication Process PDMS Electrode Array

Material Properties & Geometry

• Material Properties– PDMS: E = 500kPa, υ = 0.5

– Gold: E = 78GPa, υ = 0.44

• Geometry– PDMS: t = 100μm

– Gold: t =100nm, w = 30μm,

L = 240μm, pitch (p) = 120μm

• Loading Condition– Plane Strain

– Biaxial Loading—10% Strain

G. Yang, et al. Design of Microfabricated Strain Gauge Array to Monitor Bone Deformation In Vitro and In Vivo. Proc. 4th IEEE Symposium on Bioinformatics and Bioengineering. 2004

Page 57: Fabrication Process PDMS Electrode Array

1st Generation: The Sepertine

Strain Contour Plot Stress Contour Plot

Page 58: Fabrication Process PDMS Electrode Array

2nd Generation: The Horseshoe

• Geometry– PDMS: t = 100μm

– Gold: t =100nm, w = 30μm,

R = 60μm , H = 45°

D. Brosteaux, et al.. Elastic Interconnects for Stretchable Electronic Circuits using MID (Moulded Interconnect Device) Technology. Mater. Res. Soc. Symp. Proc. Vol. 926. 2006

Page 59: Fabrication Process PDMS Electrode Array

2nd Generation: The Horseshoe

Strain Contour Plot Stress Contour Plot

Results: Stresses are distributed in a wider region, instead of being concentrated in a small zone at the crests and troughs.

Strains are lower at the boundaries, decreasing potential of delamination

Page 60: Fabrication Process PDMS Electrode Array

The Meander Evolution…

Challenge: What if an electrode breaks?

How do we know if a connection is compromised?

Page 61: Fabrication Process PDMS Electrode Array

3rd Generation: Horseshoe Hairpin

Strain Contour Plot Stress Contour Plot

Results: Stresses are distributed in across the area of the electrode, however, stresses are higher in the immediate turn.

Strains are lower at the electrode.

Page 62: Fabrication Process PDMS Electrode Array

4th Generation: Angled Horseshoe Hairpin

Strain Contour Plot Stress Contour Plot

Page 63: Fabrication Process PDMS Electrode Array

Updates

• Training done: – Wbgeneral – Innotec – Amtetcher– Laser Ablator

• Training still needed: – Litho Solvent Bench

(if PPS is allowed)– EV Aligner

Page 64: Fabrication Process PDMS Electrode Array

Updates

• Fabrication: – Spinning of PDMS on Si Wafer

• 10:1, 50 ums, 1000 RPM, 90 secs (G. Yang, et al.) • O2 Plasma in Gasonics for 25 secs (program A, no lamp)• Problems – PDMS is a challenge to peel off • Possible Solution – PAA sacrificial layer

– Spinning PR on PDMS (Backup method)• SPR 3612 1.6 um, baked in the 90ºC for 30 mins• Problems – cracking of PR• Possible solution – ramping of temperature instead of baking

(suggested by Vikram). Similar to SU-8 stacking

Page 65: Fabrication Process PDMS Electrode Array

Updates

• Fabrication: – Exposure of PR on PDMS

• Karlsuss 2 (down during the weekend ruined 3 wafers)

• Tried exposure times of 1.6-2 seconds. Contact pads were overexposed, but tracks were not defined

– Cr/Au deposition in Innotec• 100 A Cr/ 1000 A Au

• Purpose – check adhesion

• Still need to strip the PR to lift the unwanted metal

Page 66: Fabrication Process PDMS Electrode Array

Updates

• Fabrication: – Spinning of PAA

– Spinning of SU-8

Page 67: Fabrication Process PDMS Electrode Array

Updates

• Masks: – SU-8 Masks are already here

– Shadow Masks Vendors

Company Type

Photosciences Beryllium Copper

Fotofab Stainless Steel

Thin Metal Parts Copper

Page 68: Fabrication Process PDMS Electrode Array

Updates

• Transparency Mask Design:

Page 69: Fabrication Process PDMS Electrode Array

Updates

• Shadow Mask Design:

Page 70: Fabrication Process PDMS Electrode Array

Action Items

• Get training on more machines

• Check actual thickness of PDMS on Dektak

• Send in shadow masks once finalized

• Characterize photo-patternable silicone (MERL)– Still waiting for SPECMAT, looks like yes from MT but

might need an official yes from Ed Meyers and Mahnaz, too

• Laser cut quartz wafers

• Trial of Ti and Au adhesion on PDMS