SPECIFICATIONS F125, F200 & F450 Furnaces The manufacturer shall provide a heating appliance tested to the current standard for burning waste oils, UL 296A (in the United States); Canadian Standard Association’s standard B140.4 and meets the requirements of the European Economic Community. The efficiency shall not be less than 80%, and the emissions shall not exceed a number 2 Bacharach spot test, when combined with an INOV8 approved unit heater or boiler and burning listed fuels. The safety system shall be rated for commercial or industrial (as distinguished from residential). CATEGORY SPECIFICATIONS F125 F200 F450 FUEL CONSUMPTION Gallons per hour (GPH) .84 1.68 3.6 BTUH Input/Output (x100) 125/100 240/200 450/382 TESTED FUELS Grade #2 Oil Yes Yes Yes Used Crankcase Oils Yes Yes Yes Transmission & Hydraulic Oils Yes Yes Yes Crankcase oil with 10% gasoline Yes Yes Yes 90 Weight Gear Box Oil Yes Yes Yes 175 weight Heat Transfer Oil Yes Yes Yes Mineral Spirits Solvent Yes Yes Yes Machine Shop Cutting Oil Yes Yes Yes Vegetable Oils Yes Yes Yes ADDITIONAL FUELS Synthetic oils Yes Yes Yes Commercial & military jet fuels Yes Yes Yes Grades #1, #3, and #4 heating oils Yes Yes Yes INDUSTRIAL SAFETY Fireye Combustion Control Yes Yes Yes CONTROLS Ultra-violet Flame detector Yes Yes Yes 90 Second pre-purge Yes Yes Yes Continual proof of atomizing air Yes Yes Yes Continual proof of combustion air Yes Yes Yes Safe-start sequence Yes Yes Yes Trial for ignition timing (in seconds) 10 10 10 Flame failure response timing (in seconds) 3 3 3 Safety Shut-down indicator (visual) Yes Yes Yes Fuel shut-off by electrically operated valve & mechanically driven needle into oil nozzle Yes Yes Yes Line Voltage thermostat controlling all burner Yes Yes Yes power DIMENSIONS (standard) Height (with burner on F450) 24" 36" 40” / 54" Width / (with burner on F200): 24" 38" 40" Length (with blower & burner on F125): 84" 37" 55” / 79" STACK Inches of diameter 6" 8" 8" Height (without elbows) 10' 12' 14' Draft (inches of water) -0.03 to-.04 -0.03 to -.04 -0.03 to -.04

Upload: calelec-heating

Post on 25-Mar-2016

218 views

Category:

Documents


4 download

DESCRIPTION

F-125, F-200, F-450 Furnace Specification Sheet

TRANSCRIPT

SPECIFICATIONS

F125, F200 & F450 Furnaces The manufacturer shall provide a heating appliance tested to the current standard for burning waste oils, UL 296A (in the United States); Canadian Standard Association’s standard B140.4 and meets the requirements of the European Economic Community. The efficiency shall not be less than 80%, and the emissions shall not exceed a number 2 Bacharach spot test, when combined with an INOV8 approved unit heater or boiler and burning listed fuels. The safety system shall be rated for commercial or industrial (as distinguished from residential).

CATEGORY SPECIFICATIONS F125 F200 F450 FUEL CONSUMPTION Gallons per hour (GPH) .84 1.68 3.6 BTUH Input/Output (x100) 125/100 240/200 450/382 TESTED FUELS Grade #2 Oil Yes Yes Yes Used Crankcase Oils Yes Yes Yes Transmission & Hydraulic Oils Yes Yes Yes Crankcase oil with 10% gasoline Yes Yes Yes 90 Weight Gear Box Oil Yes Yes Yes 175 weight Heat Transfer Oil Yes Yes Yes Mineral Spirits Solvent Yes Yes Yes Machine Shop Cutting Oil Yes Yes Yes Vegetable Oils Yes Yes Yes ADDITIONAL FUELS Synthetic oils Yes Yes Yes Commercial & military jet fuels Yes Yes Yes Grades #1, #3, and #4 heating oils Yes Yes Yes INDUSTRIAL SAFETY Fireye Combustion Control Yes Yes Yes CONTROLS Ultra-violet Flame detector Yes Yes Yes 90 Second pre-purge Yes Yes Yes Continual proof of atomizing air Yes Yes Yes Continual proof of combustion air Yes Yes Yes Safe-start sequence Yes Yes Yes Trial for ignition timing (in seconds) 10 10 10 Flame failure response timing (in seconds) 3 3 3 Safety Shut-down indicator (visual) Yes Yes Yes Fuel shut-off by electrically operated valve & mechanically driven needle into oil nozzle Yes Yes Yes Line Voltage thermostat controlling all burner Yes Yes Yes power DIMENSIONS (standard) Height (with burner on F450) 24" 36" 40” / 54" Width / (with burner on F200): 24" 38" 40" Length (with blower & burner on F125): 84" 37" 55” / 79" STACK Inches of diameter 6" 8" 8" Height (without elbows) 10' 12' 14' Draft (inches of water) -0.03 to-.04 -0.03 to -.04 -0.03 to -.04

Page 2 - Furnace Specifications

CATEGORY SPECIFICATION F125 F200 F450

COMPRESSED AIR SCFM (maximum) 2 2 2 REQUIREMENTS PSIG 30 30 30 AIR CONNECTION Fitting size to air regulator ¼ NPT ¼ NPT ¼ NPT FLAME LENGTH Changes with oil pressure (average) 2’ 3 ½’ 4’ FLAME DIAMETER Approximate 10” 12” 18” MOUNTING FLANGE Standard 3 bolt pattern DIAMETER OF AIR TUBE Enters into combustion chamber 4” 4” 5” LENGTH OF AIR TUBE Inside of combustion chamber 1 5/8” 1 5/8” 4 ½” OPENING FOR AIR TUBE Into combustion chamber of furnace 4 ¼” 4 ¼” 5 ¼” CONVENIENCE Additional attempts to establish flame Yes Yes Yes CONTROLS Automatic nozzle clean-out Yes Yes Yes Hour meter Yes Yes Yes Dirty filter indicator Yes Yes Yes Switch to test spark ignition Yes Yes Yes CABINET Material gauge, aluminized 12 14 14 CONSTRUCTION Weight (pounds) 350 450 850 FURNACE AIR MOVEMENT Blower motor (horsepower)* 1/3 1/2 1 ½ VIA PROP OR SQUIRREL Capacity - CFM (max) 1,000 2,400 4,000 CAGE BLOWER Motor speed (RPM) 1,100 1,100 1,725 Outlet openings 6” 25" 36” x 35” Static pressure - blower unit only (In. - H

2O) n/a n/a .25 - .4

ELECTRICAL Total current draw (in amps) - maximum 17 17 17 Volts 120 120 240 Required circuit protection (in amps) 20 20 20 Frequency - Hz 60 60 60 Thermostat Voltage 120 120 120 Ignition Transformer, 23 ma secondary, 10,000 V 10,000V 10,000V continuous duty shielded transformer Intermittent spark ignition (10 seconds) Yes Yes Yes BURNER MOTOR Horsepower 1/5 1/5 1/5 RPM 3,450 3,450 3,450 FUEL PUMP Suntec Model A2RA Waste Oil Pump Yes Yes Yes OIL NOZZLE Delavan Aspirated Nozzle #30609-3.1 #30609-3.1 #30609-5 EQUIPMENT PROVIDED Vapor elimination from oil Yes Yes Yes Filtration after oil heating Yes Yes Yes Heater switch Included Included Included Line voltage thermostat Included Included Included Barometric damper Included Included Included Floating oil pickup assembly Included Included Included Check valve Included Included Included Return flow vent system Included Included Included Installation & Maintenance Manual Included Included Included WARRANTY One year full warranty on parts (not labor), 10 year limited on furnace cabinet ** The F200 with squirrel cage blower has 1 horsepower motor