GSI Electronics Inc. 5200 Armand Frappier Saint-Hubert, Qc Canada J3Z 1G5 Phone: 1-877-926-2777 E-mail: [email protected] EXPERT SERIES II BASIC #891-00395 REV 15 REV 23 Page 1 AP ← [13 -] ← [13 IN] ← [14VDC -] ← [14VDC +] ← [0-10V 2-] ← [0-10V 2 IN] ← [0-10V 1 IN] ← [0-10V 1-] [15 IN] → [14VDC +] → [14 IN] → [14VDC -] → [14VDC +] → L2 (N) L1 20+ 20 - Pot + 22 + 22 - 14Vdc+ 21 + ← 21 - ← 14Vdc + 14Vdc - 4 3 2 1 4 3 2 1 4 3 2 1 [15 IN] → [14VDC +] → L1 L2 (N) GND [11 IN] → [11 -] → [POT +] → Mounting Instructions — Leave a clear- ance of at least 16” (400 mm) to the left of the controller box to allow the cover to be removed for maintenance. Cable Entry — Punch holes at the bottom of the enclosure to allow wires to be introduced in the controller. Do not drill the top or side panels of the enclosure. Alarm System — Installation of a good quality alarm system is strongly suggested to warn of power failures and high/low tem- peratures. Surge Protection — Provide a surge pro- tection (including lightning protection) from the power supply to the controller and from the control to the sensors. Consult a certi- fied electrician if required. 3-Phase Power — Same phases must be used to power the variable fans and the controls on 3 phases power. Low Voltage Wires — Install low voltage ca- bles at least 12 inches (300 mm) away from high voltage cables (120, 230 or 380 Vac or 24 Vdc). Always use twisted shielded cables to wire low voltage devices and always cross high and low voltage cables at a 90° angle. This applies to : - Sensor cables - Potentiometer cables - Communication cables - Computer link cables - 0-10V loads - All other low voltage devices. Water Meter — The water meter out- put should be a dry contact and should not pulse faster than 60 times a second (60Hz). A 22/12 AWG gauge cable no lon- ger than 2000 feet (0.6 km) can be used to connect the water meter. Do not use a cable longer than 2000 feet even if a larger cable is used. Do not run the meter cable outside the building! Relays— Dry Contact, 15 A RES, 50/60 Hz 16 FLA @ 120 Vac (1HP, 746 W) 12 FLA @ 240 Vac (2HP, 1490 W) Load Supplies — 120-240 Vac, 50-60HZ 12-24 Vdc Backup Thermostats — The backup thermostats are shown for illustration pur- poses only. Sufficient backup thermostats must be used to ensure ventilation if the controller loses power. Fuse Box — We recommend installing a fuse box on each stage. Potentiometer’s Color Legend Wire # Commander Actuator VonWeise Actuator 1 White Red 2 Red Black 3 Black White Whisker switch 1 (opt.) Whisker switch 2 (opt.) The controller’s power supply must be connected to a 15A breaker! Communication Port: Insert an A-Com 1 card to use the A-BOX System. Module Port: Insert a Comlink-1 card into the MODULE port if an external module is connected to the controller. EXPERT SERIES II BASIC Feeder 1 (opt.) Feeder 2 (opt.) (See overleaf) Control Power supply 90-240Vac 50/60Hz 30W max White : not used Green Black Red Inside Probe 1 Inside Probe 2 (opt.) Inside Probe 3 (opt.) Inside Probe 4 (opt.) Inside Probe 5 (opt.) Inside Probe 6 (opt.) Inside Probe 7 (opt.) Outisde Probe 1 (opt.) Inside Probe 8 (opt.) Outisde Probe 2 (opt.) Water meter (opt.) Static pressure sensor Dwyer Gauge (optional) Inlet 1 potentiometer 1, 5 or 10 KOhms, 10 turns Refer to the color legend below Inside humidity probe (optional) HP1, HS-100 0-10V Load 1 0-10V Load 2 0-10V Load 1 MODULE Communication (see overleaf) PC Communication (see overleaf) Alarm Power supply Backup thermostat (not included) Load 20 Power Supply On/Off Load Rain sensor (optional) Outside humidity probe (optional) Wind direction sensor (optional) Wind speed sensor (optional) Red dot Red Relative humidity sensor HS-1 Relative humidity sensor HS-1 Weather Station Junction Box (opt.) Black Green Red Black Green 0-10V Load 2 Ferrites (see page 4) Ferrites (see page 4) Please scan the QR Code to access the complete manual or visit the website. AP: http://www.automatedproduction.com WIRING DIAGRAM EN

Upload: others

Post on 25-Jun-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Expert Series 2 Basic

GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected]

EXPERT SERIES II BASIC

#891-00395 REV 15

REV 23

Page 1

AP

← [13 -]

← [13 IN

]

← [14V

DC

-]

← [14V

DC

+]

← [0-10V 2-]

← [0-10V 2 IN]

← [0-10V 1 IN]

← [0-10V 1-]

[15 IN] → [14VDC +] →

[14 IN] → [14VDC -] → [14VDC +] →

L2 (N)

L1

→ 20+→ 20 -→ Pot +→ 22 +→ 22 -→ 14Vdc+

21 + ← 21 - ←

14Vdc + ← 14Vdc - ←

4

3

2

1

4

3

2

1

4

3

2

1

[15 IN] → [14VDC +] →

L1 L2 (N)

GND

[11 IN] → [11 -] →

[POT +] →

T° T° T° T° T° T° T° T° T° T°

Mounting Instructions — Leave a clear-ance of at least 16” (400 mm) to the left of the controller box to allow the cover to be removed for maintenance.

Cable Entry — Punch holes at the bottom of the enclosure to allow wires to be introduced in the controller. Do not drill the top or side panels of the enclosure.

Alarm System — Installation of a good quality alarm system is strongly suggested to warn of power failures and high/low tem-peratures.

Surge Protection — Provide a surge pro-tection (including lightning protection) from the power supply to the controller and from the control to the sensors. Consult a certi-fied electrician if required.

3-Phase Power — Same phases must be used to power the variable fans and the controls on 3 phases power.

Low Voltage Wires — Install low voltage ca-bles at least 12 inches (300 mm) away from high voltage cables (120, 230 or 380 Vac or 24 Vdc). Always use twisted shielded cables to wire low voltage devices and always cross high and low voltage cables at a 90° angle. This applies to :- Sensor cables- Potentiometer cables- Communication cables- Computer link cables- 0-10V loads- All other low voltage devices.

Water Meter — The water meter out-put should be a dry contact and should not pulse faster than 60 times a second (60Hz). A 22/12 AWG gauge cable no lon-ger than 2000 feet (0.6 km) can be used to connect the water meter. Do not use a cable longer than 2000 feet even if a larger cable is used. Do not run the meter cable outside the building!

Relays— Dry Contact, 15 A RES, 50/60 Hz16 FLA @ 120 Vac (1HP, 746 W)12 FLA @ 240 Vac (2HP, 1490 W)

Load Supplies — 120-240 Vac, 50-60HZ 12-24 Vdc

Backup Thermostats — The backup thermostats are shown for illustration pur-poses only. Sufficient backup thermostats must be used to ensure ventilation if the controller loses power.

Fuse Box — We recommend installing a fuse box on each stage.

Potentiometer’s Color LegendWire

#Commander

ActuatorVonWeise Actuator

1 White Red2 Red Black3 Black White

Whisker sw

itch 1 (opt.)W

hisker switch 2 (opt.)

The controller’s power supply must be connected to a 15A breaker!

Communication Port:Insert an A-Com 1 card to use the A-BOX System.

Module Port:Insert a Comlink-1 card into the MODULE port if an external module is connected to the controller.

EXPERT SERIES II BASIC

Feeder 1 (opt.)Feeder 2 (opt.)

(See overleaf)

Control Power supply

90-240Vac 50/60Hz

30W max

White : not usedGreenBlackRed

Inside Probe 1Inside Probe 2 (opt.)Inside Probe 3 (opt.)Inside Probe 4 (opt.)Inside Probe 5 (opt.)Inside Probe 6 (opt.)Inside Probe 7 (opt.)

Outisde Probe 1 (opt.)

Inside Probe 8 (opt.)

Outisde Probe 2 (opt.)

Water m

eter (opt.)

Static pressuresensor

Dwyer Gauge(optional)

Inlet 1 potentiometer1, 5 or 10 KOhms, 10 turns

Refer to the color legend below

Insidehumidity probe(optional) HP1, HS-100

0-10VLoad 1

0-10VLoad 2

0-10VLoad 1

MODULE Communication (see overleaf)PC Communication (see overleaf)

AlarmPower supply

Backup thermostat (not included)

Load 20Power Supply

On/OffLoad

Rain sensor(optional)

Outside humidity probe(optional)

Winddirectionsensor(optional)

Windspeedsensor(optional)

Red dot

Red

Relative humidity sensor HS-1

Relative humidity sensor

HS-1

Weather StationJunction Box (opt.)

BlackGreenRed

BlackGreen

0-10VLoad 2

Ferrites(see page 4)

Ferrites(see page 4)

Please scan the QR Code to access the complete manual or visit the website. AP: http://www.automatedproduction.com

WIRING DIAGRAM EN

Page 2: Expert Series 2 Basic

EXPERT SERIES II BASIC

#891-00395 REV 15

Page 2

← [M

OD

2]

← [14V

DC

-]

← [M

OD

1]

1 2 GND

COM

← [M

OD

2]

← [M

OD

1]

← [PC1]← [PC2]← [14VDC-]

1 2

COM

← [14VDC -]

← [MOD 1]

← [14VDC +]

← [MOD 2]

12

34

SH

MO

DU

LE

Variable output 2Power supply

Variable output 1Power supply

230Vac, 10A, 1.5HP (230Vac)/0.5HP (115Vac)

230Vac, 10A, 1.5HP (230Vac)/ 0.5HP (115Vac)

EXPERT SERIES II BASIC

WME-8Water meter module (opt.)ID #2

Relay Panel CS (opt.)ID #1(see graph below to connect a non-CS Relay Panel)

Relay Panel Non-CS model ID#1

(see overleaf)

(see overleaf) (see overleaf)

Auxiliary output 1

Auxiliary output 2

Green

Shield

Black

Black

Red

RedG

reen

White

EXPERT SERIES II BASIC

BlackR

ed

Shield

A-BOX System (opt.)

SureLink-2 Module

*Refer to the SureLink-2 manual to set the end of line selectors properly.

Connector A

Wiring Diagram for a Non-CS Relay Panel

ENWIRING DIAGRAM

Page 3: Expert Series 2 Basic

EXPERT SERIES II BASIC

#891-00395 REV 15

Page 3

→ 20+→ 20 -→ Pot +→ 22 +→ 22 -→ 14Vdc+

Expert Series II - #1 Expert Series II - #2

WINDDIRECTION

WINDSPEED

Jct. Box

Wiring Diagram for two Expert Series II in parallel with the same weather station probe

ENWIRING DIAGRAM

(S) Green

(-) Black

(+) Red

(S) Green

(-) Black

(+) Red

Page 4: Expert Series 2 Basic

EXPERT SERIES II BASIC

#891-00395 REV 15

Page 4

20+

22+(S) GREEN(-) BLACK(+) RED

(S) GREEN(-) BLACK(+) RED

21-21+

22-14Vdc+

14Vdc+14Vdc-

21-21+14Vdc+14Vdc-

20-POT+

Ferrite p/n 118-00022(Only Wires, No Jacket and Shield)Jacket

Shieldor

Drain Wire

To Expert Series IIInput Board

To Expert Series IIInput Board

To Expert Series IIInput Board

Connect to Earth

Connect to Earth

Connect to Earth

Cable from WIND DIRECTION

Cable from RAIN SENSOR

Cable from WIND SPEED

Inside Controller (One Cable Per Sensor)

20+

22+(S) GREEN(-) BLACK(+) RED

(S) GREEN(-) BLACK(+) RED

21-21+

22-14Vdc+

14Vdc+14Vdc-

21-21+14Vdc+14Vdc-

20-POT+

Ferrite p/n 118-00022(Only Wires, No Jacket and Shield)

Jacket

Shieldor

Drain WireTo Expert Series II

Input Board

To Expert Series IIInput Board

To Expert Series IIInput BoardConnect to Earth

Cable from WIND DIRECTION, WIND SPEED and RAIN SENSOR

Inside Controller (One Cable For All Sensors)

OR

Ferrite Installation for Lightning Strike and Noisy Environment

ENWIRING DIAGRAM

Page 5: Expert Series 2 Basic

GSI Electronics Inc. • 5200 Armand Frappier Saint-Hubert, Qc • Canada J3Z 1G5 • Phone: 1-877-926-2777 E-mail: [email protected]

EXPERT SERIES II BASIC

#891-00395 REV 15

REV 23

Page 1

AP

← [13 -]

← [13 IN

]

← [14V

DC

-]

← [14V

DC

+]

← [0-10V 2-]

← [0-10V 2 IN]

← [0-10V 1 IN]

← [0-10V 1-]

[15 IN] → [14VDC +] →

[14 IN] → [14VDC -] → [14VDC +] →

L2 (N)

L1

→ 20+→ 20 -→ Pot +→ 22 +→ 22 -→ 14Vdc+

21 + ← 21 - ←

14Vdc + ← 14Vdc - ←

4

3

2

1

4

3

2

1

4

3

2

1

[15 IN] → [14VDC +] →

L1 L2 (N)

GND

[11 IN] → [11 -] →

[POT +] →

T° T° T° T° T° T° T° T° T° T°

Instrucciones de montaje — Deje un es-pacio de por lo menos 400 mm (16“) a la iz-quierda del controlador para poder quitar la cubierta y darle mantenimiento a la unidad.

Conexiones de los cables — Perfore los orificios en la parte inferior de la caja para permitir que se introduzcan los cables en el controlador. No perfore los paneles su-periores ni laterales de la caja.

Sistema de alarma — Se recomienda encarecidamente instalar un sistema de alarma de buena calidad para advertir las fallas de energía y las temperaturas altas y bajas

Corriente trifásica — Se deben usar las mismas fases para energizar los ventila-dores de velocidad variable y los controla-dores de corriente trifásica.

Protección contra sobretensiones — Instale protección contra sobretensiones temporales (incluyendo protección contra rayos) desde la fuente de energía hasta el control y desde el control hasta el sensor extendido de salida. Consulte un electri-cista certificado para las indicaciones par-ticulares.

Cables de bajo voltaje — Separe los cables de baja tensión al menos 300 mm (12”) de los cables de alta tensión (120, 230 o 380 Vca o 24Vcd). Cruce siempre los cables de baja tensión formando ángu-los de 90º y use siempre cables trenzados blindados para conectar los cables de baja tensión. Esto aplica a :- Cables de sondas- Cables de potenciómetro- Cables de communicación- Cables de conexión al computador- Cargas 0-10V. - Otro dispositivo a baja tensión.

Medidor de agua — La salida del medidor de agua debe ser un contacto seco y la ca-dencia de impulsos no deberá ser mayor de 60 por seg (60 hz). Un cable estándar (22/12 awg) puede ser usado para conec-tar el medición de agua. El cable no debe ser mas largo que 600 metros (2,000 pies) aún si un cable más largo es utilizado. ¡Nunca pase el cable de contacto solido por fuera de la estructura!

Relés— Contacto seco, 15 A RES, 50/60 Hz16 FLA @ 120 Vca (1HP, 746 W)12 FLA @ 240 Vca (2HP, 1490 W)

Capacidades de carga — 120-240 Vca, 50-60HZ 12-24 Vcc

Termostatos de respaldo — Los termo-statos que aquí aparecen sólo sirven de ilustración. Se deberá utilizar un número suficiente de termostatos de respaldo que aseguren la ventilación en caso de que se interrumpa la corriente al controlador.

Caja de fusibles — Se recomienda insta-lar una caja de fusibles en cada etapa.

Colores de los cables del potenció-metro

#Actuador

CommanderActuador VonWeise

1 Blanco Rojo2 Rojo Negro3 Negro Blanco

Interruptor whisker 1 (opc.)

Interruptor whisker 2 (opc.)

El suministro de energía del contro-lador debe encon-trarse conectado a un interruptor 15A.

Si un A-BOX se encuentra conectado al controlador, inserte una tarjeta A-Com 1 en conector “PC”.

Si un módulo externo se encuentra conectado al controlador, inserte una tarjeta Comlink-1 en conector “MODULE”.

EXPERT SERIES II BASIC

(Ver a la vuelta)

Fuente de alimentación de

control 90-240Vca

50/60Hz 30W máx

Sensor Int. 1Sensor Int. 2 (opc.)Sensor Int. 3 (opc.)Sensor Int. 4 (opc.)Sensor Int. 5 (opc.)Sensor Int. 6 (opc.)Sensor Int. 7 (opc.)

Sensor Ext. 1 (opc.)Sensor Int. 8 (opc.)

Sensor Ext. 2 (opc.)

Medidor de agua (opc.)

Alimentador 1 (opt.)

Alimentador 2 (opt.)

Blanco : no utilizadoVerdeNegroRojo

Sensor depresión estática

Dwyer Gauge(opcional)

Sensorde humedad

relativa exterior(opcional)

Potenciómetro de la entrada de aire 11, 5 o 10 KOhms, 10 espiras

(ver la inscripción de color que figura a continuación)

Sensorde humedadrelativa interior(opcional) HP1, HS-100

0-10VCarga 1

0-10VCarga 2

Comunicación MÓDULO(ver a la vuelta)Comunicación PC (ver a la vuelta)

Fuente de alimentación de la alarma

0-10VCarga

1

0-10VCarga

2

Thermostato de respaldo (opc.)

Fuente de alimentación

Carga 20

CargaOn/Off

Caja de conexiones de la estación meteorológica (opcional)

NegroVerdeRojo

NegroVerde

Rojo

Sensor de humedad

relativa HS-1

Sensor de humedad relativa HS-1

Sensor de velocidad del

viento(opcional)

Sensor de dirección del

viento(opcional)

Punto Rojo

Ferritas (ver página 4)

Ferritas (ver página 4)

Escanee el código QR para acceder al manual completo o visite el sitio web. AP: http://www.automatedproduction.com

DIAGRAMA DE CABLEADO

Page 6: Expert Series 2 Basic

EXPERT SERIES II BASIC

#891-00395 REV 15

Page 2

← [M

OD

2]

← [14V

DC

-]

← [M

OD

1]

1 2 GND

COM

← [M

OD

2]

← [M

OD

1]

← [PC1]← [PC2]← [14VDC-]

1 2

COM

← [14VDC -]

← [MOD 1]

← [14VDC +]

← [MOD 2]

12

34

SH

MO

DU

LE

Fuente de alimen-tación de la salida variable 2

Fuente de alimen-tación de la salida variable 1

230Vca, 10A, 1.5HP (230Vca) /0.5HP (115Vca)

230Vca, 10A, 1.5HP (230Vca) /0.5HP (115Vca)

EXPERT SERIES II BASIC

WME-8(módulo de medidor de agua (opc.)ID #2

Panel de relés modelo No-CSID #1

Panel de relés CS (opc.)ID #1(ver debajo para conectar un panel de relés que no utiliza la tecnología CS).

(Ver a la vuelta)

(Ver a la vuelta) (Ver a la vuelta)

Salida auxiliar 1

Salida auxiliar 2

Verde

Blindaje

Negro

Negro

Rojo

RojoVerde

Blanco

Conectar un panel de relés no-CS

EXPERT SERIES II BASIC

Negro

Rojo

Blindaje

Sistema A-BOX(Opcional)

Módulo SureLink-2

*Réfierase al manual del SureLink-2 para la disposición adecuada del selectador de fin de linea (EOL).

Conector A

DIAGRAMA DE CABLEADO ES

Page 7: Expert Series 2 Basic

EXPERT SERIES II BASIC

#891-00395 REV 15

Page 3

→ 20+→ 20 -→ Pot +→ 22 +→ 22 -→ 14Vdc+

Expert Series II - #1 Expert Series II - #2

WINDDIRECTION

WINDSPEED

Jct. Box

Caja de conexiones

Diagrama de cableado de dos Expert Series II en paralelo con las mismas sondas de estación meteorológica.

DIAGRAMA DE CABLEADO

Velocidad del viento

Dirección del viento

(S) Verde

(-) Negro

(+) Rojo

(S) Verde

(-) Negro

(+) Rojo

ES

Page 8: Expert Series 2 Basic

EXPERT SERIES II BASIC

#891-00395 REV 15

Page 4

20+

22+(S) GREEN(-) BLACK(+) RED

(S) GREEN(-) BLACK(+) RED

21-21+

22-14Vdc+

14Vdc+14Vdc-

21-21+14Vdc+14Vdc-

20-POT+

Ferrite p/n 118-00022(Only Wires, No Jacket and Shield)Jacket

Shieldor

Drain Wire

To Expert Series IIInput Board

To Expert Series IIInput Board

To Expert Series IIInput Board

Connect to Earth

Connect to Earth

Connect to Earth

Cable from WIND DIRECTION

Cable from RAIN SENSOR

Cable from WIND SPEED

Inside Controller (One Cable Per Sensor)

20+

22+(S) GREEN(-) BLACK(+) RED

(S) GREEN(-) BLACK(+) RED

21-21+

22-14Vdc+

14Vdc+14Vdc-

21-21+14Vdc+14Vdc-

20-POT+

Ferrite p/n 118-00022(Only Wires, No Jacket and Shield)

Jacket

Shieldor

Drain WireTo Expert Series II

Input Board

To Expert Series IIInput Board

To Expert Series IIInput BoardConnect to Earth

Cable from WIND DIRECTION, WIND SPEED and RAIN SENSOR

Inside Controller (One Cable For All Sensors)

OR

DIAGRAMA DE CABLEADO

Cable de DIRECCIÓN DEL VIENTO

Cable de LA VELOCIDAD DEL VIENTO

Cable del SENSOR DE LLUVIA

Conectarse a la Tierra

Conectarse a la Tierra

Conectarse a la Tierra

(-) Negro(S) Verde

(+) Rojo

(-) Negro(S) Verde

(+) Rojo

A la placa de entrada Expert Series II

A la placa de entrada Expert Series II

A la placa de entrada Expert Series II

Solo cables, sin chaqueta y escudo

Blindaje o alambre de drenaje

La envoltura

La envolturaBlindaje o alambre de drenaje

(-) Negro(S) Verde

(+) Rojo

(-) Negro(S) Verde

(+) Rojo

Solo cables, sin chaqueta y escudo

A la placa de entrada Expert Series II

A la placa de entrada Expert Series II

A la placa de entrada Expert Series II

Conectarse a la Tierra

Cable DE DIRECCIÓN DEL VIENTO, VELOCIDAD DEL VIENTO Y SENSOR DE LLUVIA

CONTROLADOR INTERNO (UN CABLE POR SENSOR)

CONTROLADOR INTERIOR (UN CABLE PARA TODOS LOS SENSORES)

Instalación de ferrita para relámpagos y entornos ruidosos