experimental studies of a single story …release unlimited 19. security class (this report)...

220
REPORT NO. UCB/EERC-89/15 AUGUST 1989 PB91-229211 EARTHQUAKE ENGINEERING RESEARCH CENTER ---- EXPERIMENTAL STUDIES OF A SINGLE STORY STEEL STRUCTURE WITH FIXED, SEMI-RIGID AND FLEXIBLE CONNECTIONS by MARWAN N. NADER ABOLHASSAN ASTANEH-ASL Report to the National Science Foundation ----------tl----L.---------- --- COLLEGE OF ENGINEERING UNIVERSITY OF CALIFORNIA AT BERKELEY REPRODUCED BY U.S. DEPARTMENT OF COMMERCE NATIONAL TECHNICAl INFORMATION SERVICE SPRINGFIELD, VA 22161

Upload: others

Post on 17-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

REPORT NO.

UCB/EERC-89/15

AUGUST 1989

PB91-229211

EARTHQUAKE ENGINEERING RESEARCH CENTER

-------+-----------------~ ----

EXPERIMENTAL STUDIES OF ASINGLE STORY STEEL STRUCTUREWITH FIXED, SEMI-RIGID ANDFLEXIBLE CONNECTIONS

by

MARWAN N. NADER

ABOLHASSAN ASTANEH-ASL

Report to the National Science Foundation

----------tl----L.------------ -

COLLEGE OF ENGINEERING

UNIVERSITY OF CALIFORNIA AT BERKELEY

REPRODUCED BYU.S. DEPARTMENT OF COMMERCE

NATIONAL TECHNICAlINFORMATION SERVICESPRINGFIELD, VA 22161

Page 2: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

'0

--J- b

For sale by the National Technical Information

Service, U.S. Department of Commerce,

Springfield, Virginia 22161

See back of report for up to date listing of

EERC reports.

DISCLAIMERAny OpIniOnS, findings, and conclusions or

recommendations expressed in this publica­

tion are those of the authors and do not nec­

essarily reflect the views of the National Sci­ence Foundation or the Earthquake

Engineering Research Center, University of

California at Berkeley.

Page 3: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30272 -101

REPORT DOCUMENTATION \1. REPORT NO.

PAGE NSF/ENG-89027PB91-229211

-

5. Report Date

August 1989... Title and Subtitle

Experimental Studies of a Single Story Steel Structure with fixed,Semi-Rigid and Flexible Connections r~-------------------------;

7. Author{s)

M.N. Nader and A. Astaneh-Asl9. Performing Organization Name and Address

Earthquake Engineering Research CenterUniversity of California, Berkeley1301 S 46th St.Richmond, CA 94804

12. Sponsoring Organization Name and Address

National Science Foundation1800 G. St. NWWashington, DC 20550

15. Supplementary Notes

8. Performing Orvanlution Rept. No.

UCB/EERC-89/1510. Project/Task/Work Unit No.

11. Contract(C) or Grant(G) No.

(C)

(G) CES-8818786

13. TYf)4i of Report & Period Covered

14.

16. Abstract (Umit:200 words) This report describes recent experimental results on the dynamic behav- I

ior of a one story steel structure tested with fixed, semi-rigid, and flexible connections.The structure was subjected to various intensities of three historical earthquake accel­eration time histories by means of the shaking table at the Earthquake Engineering ResearchCenter at the University of California, Berkeley.

The details of the structure are presented together with the instrumentation programs;the extent of the data collected in the tests is described. In addition, to the dynamicproperties of the structure, moment-rotation, shear-rotation, and several other responseparameters of the three different connections are presented.

The global responses of the structure with the three different connections under threetypes of excitations are examined. The behavior of the structure in these tests rangedfrom elastic to inelastic. Local responses of the structure such as force and deformationtime histories, hysteresis diagrams and tabulated extreme values are shown. Importantobservations are made on the test results in each of the tests.

The behavior of flexible and semi-rigid structures under dynamic loading is studied,and their respective responses are compared to that of the fixed structure subjected tosimilar earthquakes. The use of flexible and semi-rigid structures in low to moderateearthquake zones is investigated and commented on.

17. Document Analysis a. Descriptors

b. Identifiel'!;/Open-Ended Terms

c. COSATI Field/Group

IS. Availability Statemen~

Release Unlimited19. Security Class (This Report)

unclassified20. Security Class (This Page)

unclassified

21. No. of Pa ges

21722. Price

(See ANSI-Z39.18) See Instructions on Rever".. • OPTIONAL FORM 272 (4-77)(Formerly NTIS-35)Oe)artment of Commerce

Page 4: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price
Page 5: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

EXPERIMENTAL STUDIES OF A SINGLE STORY

STEEL STRUCTURE WITH FIXED, SEMI-RIGID

AND FLEXIBLE CONNECTIONS

by

Marwan N. Nader

Graduate Student

Department of Civil Engineering

University of California, Berkeley

and

Abolhassan Astaneh-Asl

Associate Professor of Civil Engineering

Earthquake Engineering Research Center

University of California, Berkeley

Report to National Science Foundation

Project No. CES-8818786

Report No. UCBjEERC-89j15

Earthquake Engineering Research Center

College of Engineering

University of California, Berkeley

August 1989

Page 6: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price
Page 7: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

ABSTRACT

This report describes recent experimental results on the dynamic behavior of

a one story steel structure tested with fixed, semi-rigid, and flexible connections.

The structure was subjected to various intensities of three historical earthquake

acceleration time histories by means of the shaking table at the Earthquake

Engineering Research Center at the University of California, Berkeley.

The details of the structure are presented together with the instrumentation

programs; the extent of the data collected in the tests is described. In addition, to

the dynamic properties of the structure, moment- rotation, shear-rotation, and.

several other response parameters of the three different connections are presented.

The global responses of the structure with the three different connections

under three types of excitations are examined. The behavior of the structure in

these tests ranged from elastic to inelastic. Local responses of the structure such as

force and deformation time histories, hysteresis diagrams, and tabulated extreme

values are shown. Important observations are made on the test results in each of

the tests.

The behavior of flexible and semi-rigid structures under dynamic loading is

studied, and their respective responses are compared to that of the fixed structure

subjected to similar earthquakes. The use of flexible and semi-rigid structures in

low to moderate earthquake zones is investigated and commented on.

-i- c..

Page 8: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Acknowledgments

The research described in this report was supported by the National Science

Foundation through Grant No. CES-8818786. The support of Dr. Shih-Chi Liu,

programs director for the National Science Foundation is greatly appreciated.

Any opinions, findings, and conclusions are those of the authors and do not neces­

sarily reflect the views of the sponsor.

The assistance provided by research assistants Jie-hua Shen, and Ricardo J.

Azcarate in conducting the experiments is acknowledged. The staff of the Earth­

quake Engineering Research Center, particularly Don Clyde, has provided invalu­

able assistance and support over the course of the experimental program; these

contributions are acknowledged.

-ii-

Page 9: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Table of Contents

ABSTRACT .ACKNOWLEDGMENTS iiT.ABLE OF CONTENTS iiiLIST OF TABLES vLIST OF FIGURES VI

1. INTRODUCTION 11.1 Introduction 11.2 Literature Review 21.3 Objective and Scope of the Research 3

2. TEST SET-UP 42.1 Shaking Table Facility and Data Acquisition System 42.2 Test Structure

2.2.1 Geometry of the Structure 52.2.2 Material and Section Properties of the Structure 62.2.3 Design Criteria 62.2.4 Safety Considerations 7

3. INSTRUMENTATION 83.1 Introduction 83.2 Types of Transducers 9

3.2.1 Accelerometers 93.2.2 Potentiometers 93.2.3 DCDT's 103.2.4 Electric Strain Gages 10

3.3 Structural Response Measurement3.3.1 Floor Acceleration and Displacement 113.3.2 Connection Deformation Measurement 123.3.3 Force Measurement 12

3.4 Instrumentation Channel Schedule 134. TEST PROGRAM 14

4.1 Introduction 144.2 Test Sequence 144.3 Runs Selected For Presentation 15

5. DATA REDUCTION 165.1 Introduction 165.2 Data Noise 175.3 Sign Convention 185.4 Data Reduction

-iii-

Page 10: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

5.4.1 Table Motion Data 185.4.2 Structural Response 19

6. TEST'RESULTS 236.1 Introduction 236.2 0.35g Taft Earthquake 23

6.2.1 Checking Performance of the Structure during Testing 246.2.2 Global Response of the Structure 256.2.3 Connection Response 276.2.4 Other Significant Responses 30

'6.3 Test Data of the Selected Test Runs6.3.1 Introduction :.......................................................... 316.3.2 Important Observations During Testing 316.3.3 Tables of Extreme Response Values 346.3.4 Description of the Schedule of Plots 35

7. SUM:MARY AND CONCLUSIONS 36REFERENCES 38APPENDIX A 103APPENDIX B 205

-IV-

Page 11: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

List of Tables

Table 2.1. Section Properties 40Table 2.2. Weight of the Structure 41Table 3.1. Allocation of Various Transducers to Specific 42

ChannelsTable 4.1.a. Sequence of Testing 43Table 4.1.b. Sequence.of Testing 44Table 4.1.c. Sequence of Testing 45Table 4.2. Contents of Magnetic Tapes that Save Data 46Table 6.1. Elastic Dynamic Properties 47Table 6.2. Base Shear and Lateral Drift 47Table 6.3. Extreme Response Values For 0.15g El Centro 48Table 6.4. Extreme Response Values For 0.25g EI Centro 48Table 6.5. Extreme Response Values For 0.35g El Centro .•............................ 49Table 6.6. Extreme Response Values For 0.15g Taft 49Table 6.7. Extreme Response Values For 0.35g Taft 50Table 6.8. Extreme Response Values For a.50g Taft 50Table 6.9. Extreme Response Values For 0.35g Mexico 51Table 6.10. Extreme Response Values For 0.50g Mexico 51Table 6.11. Structure Stiffnesses 52Table 6.12. Natural Periods of Vibration 53

-v-

Page 12: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

List of Figures

Figure 1.1 Test Structure 54Figure 2.1 Test Structure Mounted on the Shaking Table 54Figure 2.2 Dimensions of the Test Structure 55Figure 2.3 Floor System and Floor-to-Beam Connection Detail 56Figure 2.4 Flexible Connection Detail 57Figure 2.5 Semi-Rigid Connection Detail 58Figure 2.6 Fixed Connection Detail 59Figure 2.7 Base Plate Detail 60Figure 2.8 Added Mass on Structure 61Figure 2.9 Safety Considerations 61Figure 3.1 Location of Accelerometers 62Figure 3.2 Location of Potentiometers 63Figure 3.3 Method of Measuring Connection Rotation 64Figure 3.4 Location of DCDT's 64Figure 3.5 Location of Strain Gages on Columns .. 65Figure 3.6 Location of Strain Gages on Diagonal Bracings 66Figure 4.1 Acceleration Time History of EI Centro Earthquake 67Figure 4.2 Acceleration Time History of Taft Earthquake 68

Figure 4.3 Acceleration Time History of Mexico Earthquake 69Figure 5.1 Fast Fourier Transform of a Typical Shaking Table 70

Ground Motion InputFigure 5.2 Typical Time History of Floor Acceleration Response 71

before and after the Ormsby Lowpass Filterwas applied

Figure 5.3 Global Sign Convention 72Figure 5.4 Connection Sign Convention 72Figure 5.5 Member Designations 73Figure 5.6 (a) Comparison of Stiffness Calculated by Strain 74

Gages and AccelerometersFigure 5.6 (b) Time History Comparison of Base Shear Calculated 75

by Strain Gages and AccelerometersFigure 6.1 Time Histories of Floor Acceleration and Added Mass 76

AccelerationFigure 6.2 Acceleration Time History of Different Components of 77

the Response of the Flexible StructureFigure 6.3 Acceleration Time History of Different Qomponents of 78

the Response of the Semi-Rigid StructureFigure 6.4 Acceleration Time History of Different Components of 79

the Response of the Fixed Structure

-vi-

Page 13: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Figure 6.5 Comparison of Displacement Time History of the 80Two Parallel Frames

Figure 6.6 Rotational Acceleration Time History for Flexible, 81Semi-Rigid, and Fixed Structures

Figure 6.7 Time History of Floor Lateral Drift of Flexible, 82Semi-Rigid, and Fixed Structures

Figure 6.8 Time History of Base Shear of Flexible, Semi-Rigid, 83and Fixed Structures

Figure 6.9 Comparison of Stiffness of Flexible, Semi-Rigid, 84and Fixed Structures

Figure 6.10 Typical Fast Fourier Transform of Flexible, 85Semi-Rigid, and Fixed Structures

Figure 6.11 Axial Forces versus Axial Deformation of Connection =#= 4 86Figure 6.12 Inelastic Deformation of The Connection Angles 87Figure 6.13 Shear Forces versus Shear Deformation of Connection =#= 4 88Figure 6.14 Moment versus Rotation of Connection =#= 4 89Figure 6.15 Schematic Diagram of Moment-Rotation Relationship 90

in Flexible ConnectionsFigure 6.16 Moment versus Shear of Connection =#= 4 91Figure 6.17 Relation Between the Slope in Moment vs Shear 92

Plot and the Location of the point of Inflectionin the Moment Diagram

Figure 6.18 Shear Force versus Rotation of Connection =#= 4 93Figure 6.19 Time History of the Axial Force in the Diagonal.............................. 94

Braces of the Flexible StructureFigure 6.20 Time History of the Axial Force in the Diagonal.............................. 95

Braces of the Semi-Rigid StructureFigure 6.21 Time History of the Axial Force in the Diagonal.............................. 96

Braces of The Fixed StructureFigure 6.22 Maximum Deflection of S-W Column For the Three 97

Structures under Dynamic LoadingFigure 6.23 Time History of The Moment in Base Plate =#= 4 98Figure 6.24 Yielding in The Columns of Semi-Rigid Structure 99

Mter 0.35g EI-CentroFigure 6.25 Plastic Deformation in Semi-Rigid Connections 100

after 0.5g TaftFigure 6.26 Slippage in Flexible Connection 101Figure 6.27 Yielding in The N-W Column of Fixed Structure after 102

0.35g Taft

-vii-

Page 14: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price
Page 15: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER ONE

INTRODUCTION

1.1 Introduction

Steel frames are constructed using three types of connections: fixed, semi­

rigid, flexible. Flexible and semi-rigid steel structures are limited to areas of low

seismicity by the Uniform Building Code (16). The reason for this limitation may

be the belief that excessive deformations will occur in structures with semi-rigid

and flexible connections, or that buckling under the structures own weight and the

P-o effect might take place during strong earthquakes. It is possible however, that

in low-rise buildings (up to 5 stories), the flexibility provided by the connections

might attract lesser inertia forces, and thus lesser deformations.

In order to investigate the effects of connection flexibility on the dynamic

response of structures, the behavior of a one story steel structure with flexible,

semi-rigid, and fixed connections was studied when subjected to three different

base excitations. Figure 1.1 gives a schematic illustration of the test specimen.

The three earthquakes are, the 1940 EI-Centro, the 1952 Taft, and the 1985

Mexico-City earthquakes. The responses of flexible and semi-rigid structures were

studied and compared with these of fixed structures subjected to similar earth­

quake loadings.

-1-

Page 16: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

1.2 Liter~tureReview

A survey of the literature on the behavior of flexible and semi-rigid struc­

tures, resulted in a number of relevant papers, some of which are summarized

here.

Shing, Gerstle, and Harsoyo (12) studied the dynamic response of low-rise

steel building frames designed by the " Type 2 Construction " method and sub­

jected to moderate earthquakes. In this study, typical flexibly connected Type 2

frames were analyzed for seismic resistance using the 1988 Uniform Building Code

(16). This study showed that these frames are adequate for seismic forces not

greater than those of zone 2B, of the UBC, but that they may not have adequate

lateral stiffness.

Hwang, Chang, Lee, and R. L. Ketter (11) investigated the seismic behavior

of a pinned-base steel gable frame structure designed according to the AISC

Manual (17). The inelastic lateral strength was evaluated and quantified. The

story drifts were up to 7% at moderate to severe damage levels, and the observed

experimental ultimate lateral strength was very close to the value of a 5% damp­

ing linear elastic response spectrum of the measured table acceleration.

Leon (13) conducted four full-scale tests on semi-rigid connections incor­

porating a composite floor slab at the University of Minnesota. These types of

connections were found to exhibit bilinear moment-rotation curves with large ini­

tial stiffness, excellent ductility and predictable ultimate moment capacity.

A study of an eccentrically braced dual steel system (EBDS) subjected to

severe earthquake ground motions was carried out by Whittaker, Uang, and Ber­

tero on the earthquake simulator at the University of California at Berkeley. A six

story EBDS system was analyzed according to current earthquake resistant regula­

tions and codes. The results of these tests showed that these dual systems have a

substantial overstrength when compared to its nominal yielding strength. The

-2-

Page 17: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

UBC requirement that a ductile moment resisting frame be designed to resist 25%

of the design base shear was found to be questionable, because such frames lack

the strength and stiffness to be compatible with the braced frames.

1.3 Objectives and Scope of the Research

The investigation reported here had the following objectives:

(1) To compare the lateral deflections of flexible and semi-rigid frames with those

of fixed frames when the structure is subjected to large base excitations

(O.5g), similar to those that occur during severe earthquakes.

(2) To compare the base shear forces that prevail in the structure for different

connections when subjected to similar earthquake loads.

(3) To investigate the moment-rotation hysteresis loops of the flexible, semi­

rigid, and fixed connections.

(4) To study the effects of plastification in the connection on the overall behavior

of the structure.

To achieve the above objectives, a single story steel frame was constructed.

The beam to column connections were changed, from simple (flexible), to semi­

rigid, to fixed. For each of the cases, three types of ground motions were used as

input motions to the structure, each applied at progressively increasing intensities,

making a total of forty four dynamic test runs. From this complete sequence of

test data, twenty four were chosen for investigation. These tests represent the full

range of performance of the structure in these experiments. The data collected is

presented in this report.

-3-

Page 18: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER TWO

TEST SET-UP

2.1 Shaking Table Facility and Data Acquisition System

The 20 feet by 20 feet shaking table is located at the Earthquake Engineering

Research Center (EERC) of the University of California at Berkeley. The shaking

table is capable of moving in the vertical direction and one horizontal direction in

such a way that strong-motion earthquakes can be simulated accurately. The

maximum displacement and velocity that can be achieved by the table are 5

inches and 25 in/sec., respectively. The shaking table may be used to subject a

structure weighing up to 100 kips to a table acceleration of 1.0 g in the horizontal

direction. The useful frequency range is from 0 to 20 Hz.

The earthquake motions, which are in the form of digitized acceleration time

histories, cannot be used directly to excite the shaking table, since the input

requires displacement time histories. Acceleration is converted to analog form

using a digital to analog converter and then changed to displacement by integrat­

ing twice using an electronic analog integrator. The amplitude scaling of the dis­

placement recording during a test is controlled using a "span" setting. A span of

1000 will give a displacement time history that has a nominal peak of 5 inches,

the capacity of the table. The table facility is described in detail by Rea and Pen­

zien (18); the data acquisition system is also described thoroughly in that report.

-4-

Page 19: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

2.2 Test Structure

A one-story one-bay structure was used in the experiments. The following

sections describe the properties of this test structure.

2.2.1 Geometry of the Structure

The test structure consisted of two parallel one bay single story frames. The

frames were connected to each other by a horizontal channel at floor level, and by

two sets of diagonal X bracing. The structure is shown in Figure 2.1 mounted on

the shaking table..The dimensions of the test structure are given in Figure 2.2.

The ground excitation was applied to the table along the unbraced frames, Figure

2.2. As mentioned earlier the beam-to-column joints were changed from simple,

to semi-rigid, to fixed connections, thus providing three different test structures.

The floor diaphragm, which was made of channels and W-shape beams, was con­

nected to the girders by heavy structural tubes. Figure 2.3 gives a detail of the

floor system and the floor-to-girder connections. As can be seen the inertia forces

developed were transferred by six reinforced heavy 12x6x1/2 inch structural tubes

to the girders of the two frames. It is evident that the concrete blocks could not

interfere with the girder deformation.

Figures 2.4, 2.5, and 2.6 show details of the flexible, semi-rigid, and fixed

beam-to-column connections, respectively. In the case of the flexible connection,

two 2x2x3/16 inch angles were used with eight A325 1/2 inch diameter bolts

bolted to the column flange and the beam web. The semi-rigid connection con­

sisted of the same double-angle connection, with additional seated 2x3-1/2x3/16

inch angles which were added on the top and bottom flanges of the beam. In this

case also 1/2 inch diameter A325 bolts were used. The fixed connection consisted

of the same shear connection detail, but the double angles were welded to the

beam to insure rigidity. Also, the flanges of the beams were welded to the columns

-5-

Page 20: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

by a full penetration field weld (E70XX) using backup plates, see Figure 2.6.

Base plates were lOxlOxl inch plates. Each base plate was bolted to another

10x1Oxl-3/4 inch plate by four 1 inch A490 bolts. The 1-3/4 inch base plate was

in turn prestressed to the table by high strength steel rods. To insure fixity of

columns to the base plates, a pair of triangular plates was used at the base of

each column. Figure 2.7 shows a detail of column base connection.

2.2.2 Material and Section Properties of the Structure

The columns were fabricated from standard rolled shapes of steel having a

yield strength of about 49 ksi according to the coupon tests. The beams were

made of W10x15 section, while the columns were made of W4x13. Table 2.1 gives

section properties of the beams and columns. The channels used to connect the

two frames along the weak axis of the columns, were C-9x15, while the diagonal

cross bracings were 2x2x1/4 angles. Table 2.1 gives the geometric properties of

these sections.

2.2.3 Design Criteria

In order to develop a period of vibration in the range of periods of actual

steel structures, six blocks of concrete were added to the structure. As shown in

Figure 2.8 the concrete blocks were prestressed to the floor framing level so as to

prevent any sliding,thus making the blocks a fully reactive mass. The concrete

blocks were set in such a way so as to have the center of mass close to the center

line of the floor framing level. The extent to which this vertical eccentricity may

affect the earthquake response is thought to be small. Estimated weights of the

steel components and the concrete blocks are listed in Table 2.3. The total weight

of the structure was calculated to be 27,423 pounds.

-6-

Page 21: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

The test structure was designed as an actual structural system and not as a

scale model of a specific prototype. The relatively small dimensions of the

members was due to the limitations of the shaking table dimensions. Member sec­

tions and, correspondingly, connection sizes were scaled down. In designing the

structure the intent was to test and observe the effect of inelasticity in the connec­

tions on the overall response of the structure. Obviously, yielding was expected in

the simple and semi-rigid connections only. Since the plastic moment of the semi­

rigid connection is larger than that of the simple, the column and beam section

moduli were controlled by the semi-rigid connection plastic moment.

2.2.4 Safety Considerations

The structures tested were planned to be subjected to severe ground motion

accelerations. Since flexible and semi-rigid frames are rarely tested under these

conditions, and their behavior is still unpredictable, two safety procedures were

adopted:

(1) A block of timber beams was built under the structure so as to protect the

table if the structure were to fail.

(2) The mass was attached loosely to a 40 kip capacity crane that would be able

to hold up the mass.

Figure 2.9 shows a detail of the above two safety procedures.

-7-

Page 22: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER THREE

INSTRUMENTATION

3.1 Introduction

To monitor the local as well as the global behavior of the structure four

types of measuring devices were mounted on the structure. In principal, it should

be sufficient to measure the behavior of one connection and to monitor the

response of one frame. However, variability in the geometry and material proper­

ties is unavoidable; hence it was necessary to include sufficient instrumentation to

verify the degree of symmetry in the structure. It was also necessary to include

some degree of redundancy in the instrumentation, so as to have some backup in

case one element of the instrumentation malfunctioned. In general, each quantity

reported here was measured and checked by means of two independent instrumen­

tation systems.

The following quantities were measured by direct instrumentation:

(1) Rotation response of three of the connections

(2) Shear displacement of the four connections

(3) Axial displacement of the four connections

(4) Shearforces in the columns in both directions

(5) Moment in each column at 24 inches from the bottom

-8-

Page 23: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(6) Axial forces in the columns

(7) Acceleration of the floor level in the vertical, and the two horizontal direc­

tions, and the rotational acceleration.

3.2 Types of Transducers

Four types of transducers were used to monitor the behavior of the structure.

Accelerometers, potentiometers, DCDT's, and strain gages were the basic measur­

ing devices used in this investigation. There were 88 data channels activated, 10 of

which were allocated to monitor the performance of the shaking table, the other

78 were used to measure the behavior of the structure . There were 16 channels

allocated for DCDT's, while 9 channels were allocated for potentiometers.

Accelerometers were allocated 5 channels, and the rest of the data channels (48)

were allocated for electric strain gages. Because various structural response quanti­

ties would eventually be determined from the data produced by these transducers,

it was necessary to understand the physical performance characteristics of these

transducers, as summarized here.

3.2.1 Accelerometers

The accelerometer was a model 141 made by Setre System, Inc. This model is

a linear accelerometer that produces a high level instantaneous DC output signal

proportional to sensed accelerations. The range of the accelerometer used is (-4g to

+4g) with 0.1% nonlinearity error.

3.2.2 Potentiometers

The potentiometer used was a model PT-101 position or displacement trans­

ducer designed for measurement from 0 to 30 inches made by Celesco Transducer

-9-

Page 24: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Products. It provides an electrical signal proportional to the linear extension of

the stainless steel cable. Nonlinearity errors are less than 0.1% of full range. Its

frequency response is up to 60 Hz, and its sensitivity is 32 mVIVlinch.

3.2.3 DCDT's

DCDT stands for Direct Current Displacement Transducer. The DCDT used

was a model 240 made by Trans Tek. Of the sixteen DCDT's used twelve had a

range of (-1 inch to +1 inch), while the other four had a range of (-0.5 inch to

+0.5 inch). Nonlinearity errors were less than 0.5%.

3.2.4 Electric Strain Gages

Two types of strain gages were used; shear strain gages and uniaxial strain

gages. The shear strain gages were model EA-13250TD-120 made by Micro­

Measurements, for which the resistance was 120 ohms and the nonlinearity error

was 0.6%. Two brands of strain gages were used to measure axial strains. On the

columns, model YFLA·2 made by Tokyo Sokki Kenkyuju Co.LTD, with a resis­

tance of 120 ohms, and a nonlinearity error of 0.5% were used. On the diagonal

bracings, CEA-06-125UW-120 model strain gages made by Micro-Measurements,

with a resistance of 120 ohms, and a nonlinearity error of 0.6% were used.

All of these gages are capable of measuring strains up to 20% according to

their respective manufacturers specifications. All were bonded to the test struc­

ture with fast setting adhesives. A synthetic rubber coating was applied on the

top of the strain gages. This coating was intended to protect the gage from humi­

dity, and chemical intrusions.

-1~

Page 25: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

3.3 Structural Response Measurement

The position of the 78 transducers used to monitor the behavior of the struc­

ture is described in the following section.

3.3.1 Floor Acceleration and Displacement

The five accelerometers that were employed in this investigation were distri­

buted as follows. Two accelerometers measured the horizontal floor response in the

direction of excitation in each of the two frames. The third accelerometer was

oriented upwards so as to detect any vertical component in the response of the

structure, while the fourth was oriented in the transverse direction of excitation to

detect any horizontal transverse component in the response. These four accelerom­

eters were all attached to the structure at the floor level center line. The fifth

accelerometer was attached to the concrete blocks at an elevation of 7 ft 5-1/2

inches, this accelerometer was used to measure the horizontal response of the mass

in the direction of excitation, and to check for any difference between the mass

and structural responses. Figure 3.1 shows the location of each of the accelerome­

ters.

Potentiometers, attached to the independent reference frame erected outside

the pit wall of the shaking table, were employed to measure the absolute displace­

ment of the floor. Very light stainless steel cables were used to connect the poten­

tiometers to their targets on the structure. Two potentiometers were used to

measure the displacement of each of the frames at floor level. Another two poten­

tiometers were used to measure the displacements of the concrete blocks. Five

potentiometers were used to measure the deformation of the S-W column. Figure

3.2 shows the location of each of the potentiometers.

-11-

Page 26: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

3.3.2 Connection Deformation Measurement

To measure the rotation of the connection four DCDT's were used as shown

in Figure 3.3. The rotation is thus given by:

e = ( 181 I + 182 I ) / h (3.1)

Since the vertical deformation of the connection was thought to be of impor­

tance, it was also measured. Figure 3.4 shows. the location of the DCDT's.

Because of the limited number of available DCDT's the rotation was only meas­

ured for three connections, while the vertical deformation was measured for all

four connections.

3.3.3 Force Measurement

Two types of strain gages were used to measure moments, shears, and axial

loads: shear strain gages, and uniaxial strain gages. Ten strain gages were

attached on each column at 24 inches from the top of the base plate. Four of

these strain gages were uniaxial resistors and were installed at the column flanges,

two on each side. Two shear strain gages were mounted on the centerline of the

column web. The other four shear strain gages were installed at the centerline of

the column flange, two on either side. Figure 3.5 shows the location of the strain

gages.

Also, uniaxial strain gages were installed on the diagonal bracings between

the two frames. Each brace had two strain gages installed at 26 inches, from the

edge of the beam, along its length. Figure 3.6 shows the location of the strain

gages.

-12-

Page 27: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

3.4 Instrumentation Channel Schedule

Table 3.1 lists the allocation of various transducers to specific channels of the

data acquisition system. As can be seen in the table , the first 10 channels were

reserved to monitor the performance of the shaking table, the next 5 channels

were used for the accelerometers. The following 16 channels were allocated for

DCDT's, the next 9 channels were allocated for potentiometers, after which the

remaining 48 channels were allocated to strain gages.

-13-

Page 28: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER FOUR

TEST PROGRAM

4.1 Introduction

In this chapter the testing sequence and the different ground motions that the

structure was subjected to are summarized. In Chapter Five the experimental

results are presented, and in Chapter Six conclusions and remarks about the

investigation are given.

4.2 Test Sequence

As discussed earlier, the steel structure was tested with three different connec­

tions, simple (flexible), semi-rigid, and fixed. Details of the steel structure are

given in Chapter Two. The intent in selecting a' test sequence was to subject each

of the three different structures to exactly the same sequence of earthquake load­

ing. For each of the three structures a sequence of tests was selected. First a tie­

back test was conducted to measure the elastic stiffness, as well as to compute the

dynamic properties of the structure. Then the structure was subjected to white

noise of intensity 0.05g, to find its natural period of vibration more precisely.

Then, a series of forced ground motions was applied. Three different historical

earthquake ground motions were used to observe the behavior of the structure

under different ground motions, and thus a variety of frequency ranges. The 1940

EI Centro SOOE earthquake, the 1952 Taft N21E earthquake, and the 1985 Mexico

-14-

Page 29: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

City (Set.) S60E earthquake were chosen. Each of the earthquakes was increased

in intensity from 0.05g to 0.5g. This resulted in a total of 44 shaking table tests.

Table 4.1 lists the sequence which was followed in testing each structure. Usually,

the data for an earthquake is collected every 0.02 seconds. Looking at column five

in Table 4.1, one can see that all of the signals were inputed at a full time scale,

except for the Mexico earthquake, which was squeezed so that the earthquake

response spectra would have a peak close to the natural period of the structure.

In column six of this table, the span of each signal is listed. A span of 5 seconds

corresponds to a horizontal table displacement of 5 inches. The experimental data

was recorded on two tapes. The contents of these two tapes with the file name for

each run are listed in Table 4.2. Figures 4.1, 4.2, and 4.3 show different accelera­

tion time histories of the ground motions that were used.

4.3 Runs Selected for Presentation

As stated earlier, one of the major purposes of this report is to present

detailed data on the structural response for a variety of test conditions. Out of

the 44 shaking table tests, 24 test runs were selected for detailed evaluation. These

24 tests give a full representation of all the tests performed. These 24 tests include

the three earthquake loadings with three different intensities for which the

behavior of the structure ranged from elastic to largely inelastic.

-15-

Page 30: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER FIVE

DATA REDUCTION

-16-

Page 31: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

5.2 Data Noise

Recorded data containing noise is an inevitable phenomenon when using an

electronic data acquisition system. Significant noise was mixed with the true signal

especially in the data collected by the accelerometers. Two kinds of undesirable

noise were encountered during the tests.

(1) High Frequency Noise: The high frequency noise could easily be identified.

A numerical filtering technique was used throughout the data reduction pro­

cedure. The Ormsby low-pass filter, was adopted and implemented into the S

computer program to remove the high frequency noise. A cut-off frequency of

20 Hz was used for the following reasons: (i) the frequency of vibration of the

structure was far lower than 20 Hz; (ii) the Fourier Amplitude of the input

excitation showed very little energy associated with frequencies higher than

20 Hz as shown in Figure 5.1; (iii) the oil column of the shaking table

changes the input frequency content at frequencies higher than 20 Hz, thus

introducing significant errors. A typical example of the time history response

before and after applying the Ormsby low-pass filter is shown in Figure 5.2.

(2) Low Frequency Noise: The low frequency noise was not filtered in general.

Filtering low frequency noise would have been wrong because of permanent

deformations or plastic strains and therefore, strain gages and DCDT's as

well as linear potentiometers were not filtered. On the other hand, accelerom­

eters were not allowed to show any permanent non-zero readings at the end

of each test run. The data recorded by the accelerometers were of very good

quality.

-17-

Page 32: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

5.3 Sign ~onvention

The following sign convention is used throughout the report:

(I) The lateral drift is positive to the right (south). Refer to Figure 5.3.

(2) The rotation of the connections corresponding to a positive lateral drift is

positive. Refer to Figure 5.4.

(3) Axial strains for elongation of the brace member are positive.

(4) Positive column shear and axial forces are induced by positive floor drift,

refer to Figure 5.3.

(5) The moment sign convention for the section at which the strain gages were

- mounted on the column is shown in Figure 5.3.

(6) The sign convention for shear and moment for the connections is shown in

Figure 5.4.

5.4 Data Reduction

5.4.1 Table Motion Data

The table motion records are an important record, for they represent the

excitations the structure was subjected to. This information will be needed for

making analytical predictions. The acceleration time histories are thought to be

the important parameter. The basic table motion for each of eight different shak­

ing table tests is presented in the form of a time history plot of acceleration, see

Figures 4.1, 4.2, and 4.3. These plots were directly obtained by plotting the

readout of the respective channels versus time, specifically, Channel 3.

-18-

Page 33: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

5.4.2 Structural Response

The global response of the structure is indicated basically by the accelerome-

ter, potentiometer, and the shear strain gage measurements. The member desig-

nation for the subsequent discussion is shown in Figure 5.5. In the following the

data reduction process for the main parameters is described.

(1) Base Shear: Since the structure under investigation had a single degree of

freedom, the shear force obtained by using the shear strain gages on each

column should agree with the shear force obtained from the accelerometers

attached to the structure. The formula by which the shear value was

obtained using the accelerometers is:

Sbase - W (ac 1 +ac 2 ) / 2

where,

Sbase = base shear in kips

W = weight of the structure in kips

ac1 = accelerometer 1 in units of g's

ac2.= accelerometer 2 in units of g's.

The formula for shear using the shear strain gages is:

Sbase - Shear 1 + Shear 2 + Shear 3 + Shear 4

where,

Sh (.) h f . I " . ". k·ear I = sear orce III co umn 1 III IpS.

-19-

(5.1)

(5.2)

Page 34: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

The shear force in column " i " can be evaluated as follows:

Shear(i) - (I/Q) tw G (sgi5-sgi4) 10- 6

where,

I = moment of inertia of the column (in4 )

Q = moment area of the column about the center

of gravity (in3 )

tw = web thickness in inches

(5.3)

G = shear modulus of elasticity (11200 ksi)

sgi5 = strain gage i5 for column" i " in micro-strains

sgi4 = strain gage i4 for column " i " in micro-strains.

A comparison of these two shear forces, shows very good agreement between

the two independently measured values. Figures 5.6(a) and 5.6(b) show a com­

parison between shear force measured by these two methods. In the data

presented, the shear forces that are used are the ones obtained from the shear

strain gages attached to the columns. The reason for using the shear strain gages

was that no low-pass filter was needed for the strain gages, besides, the shear

values obtained by both methods were the same.

In all of the plots that contain the base shear, the absolute accelerations (in

g's) of the floor can be obtained by dividing the base shear values by the weight

of the floor which was 27.42 kips.

-20-

Page 35: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(2) Relative Lateral Floor Displacement: The relative floor displacement was

obtained by subtracting the table motions from the absolute floor level

motions. The displacements were calculated using the following formula:

where,

Disp - ((pot 8 +pot 5 ) / 2 ) - ((h 1 +h 2 ) / 2 ) (5.4)

Disp = lateral displacement of the floor in inches

pot8 = potentiometer 8 in inches

pot5 = potentiometer 5 in inches

hI = horizontal displacement of shaking table (inches)

h2 = horizontal displacement of shaking table (inches)

(3) Axial Force in the columns: The axial force in the columns consisted of

two parts, static, which was equal to the weight of the structure divided by

four, and a dynamic part which was calculated as follows:

where,

Axial (i) - A E ((sgi 0 +sgi 3 +sgi 6 +sgi 9) /4) 10- 6

Axial(i) = Axial force in column "i" in kips

A = area of column cross section (in2 )

(5.5) .

E = modulus of elasticity (29000 ksi)

sg = strain gage in micro-strains

(4) Local moment in the columns: The moment in the columns at the loca­

tion where the strain gages were attached, was calculated using the following

formula:

-21-

Page 36: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Moment (i) - S E ((sgi 0 +sgi 3 -sgi 6 -sgi 9) / 4) 10-6 (5.6)

where,

Moment(i) = moment in column It i If at 24 inches from the

bottom (k -in)

S = column section modulus (in3 )

E = modulus of elasticity (29000 ksi)

sg = strain gage in micro-strains

(5) Moment at the connection: The moment at the connection was easily

. derived from the local moment and shear in each column. The following for­

mula describes the statics equation:

Moment (connection 1) = (48. 7 5) Shear 1 - Moment 1 (5.7)

(6) Connection Rotation: The method by which the connection rotation was

calculated was described earlier in section 3.3.2. The following formula shows

how the rotation was calculated for connection 1:

e = ((de 5 +dc 4 -de 3 -de 2 ) / 2 ) / 1 6. 8 7

-22"-

(5.8)

Page 37: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER SIX

TEST RESULTS

6.1 Introduction

In this chapter, the results obtained from the 24 selected shaking table tests

are presented. The chapter is divided into two parts. In the first part, an investi­

gation of the three structures (flexible, semi-rigid, and fixed) when subjected to a

simulated O.35g Taft ground motion is presented. The second part considers the

major response parameters of the structures. In this part, a description of the

behavior of each structure in each of the 24 tests is summarized, then extreme

values of various response variables are tabulated, after which time history plots,

as well as hysteresis plots, are presented.

6.2 0.35 g Taft Earthquake

A complete investigation of the three structures when subjected to a simu­

lated O.35g Taft Earthquake is presented in this section. This part of the investi­

gation had three objectives:

(1) To study the complete response of the structures, globally as well as locally,

in order to identify the parameters that affect the response significantly. The

behavior of these parameters in the 24 shaking table tests was later investi­

gated.

-23-

Page 38: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(2) For certain response parameters, one series of tests (for the three different

structures: flexible, semi-rigid, and fixed) was deemed to be sufficient for com­

parative studies of the behavior. The data collected from the O.35g Taft test

provided some of the the most dependable and significant data.

(3) Comparisons of data collected from different channels were important in

checking the validity of such assumptions as (i) the mass does not slip during

testing, and (ii) the structures tested have one major degree of freedom.

6.2.1 Checking Performance of the Structure during Tests

Using the experimental data an investigation was conducted to study the

adequacy of the structure tested. The reason for this investigation was that in

designing and constructing the test structure certain objectives were set and

assumptions were made. Therefore, it was necessary to investigate the validity of

the assumptions, and how well the structure fulfilled its function. Some of the

objectives were:

(i) to rigidly connect the mass to the floor system;

(ii) to build the structure to have one major dynamic degree of freedom;

(iii) to add some stiffness to the structure in the direction of the weak axis of

bending of the columns.

The following three plots were generated for this purpose, these are:

(a) A comparison of the time histories of accelerometers 1 and 4, for the semi­

rigid frame, see Figure 6.1. Accelerometer 1 was attached to the structure,

while accelerometer 4 was attached to the concrete blocks, refer to Figure 3.1.

This comparison was essential, because a difference between the two readings

would mean that the mass was not rigidly connected to the floor diaphragm,

and probably the mass was slipping. Figure 6.1 shows almost exact replicas,

-24-

Page 39: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

which indicates that the mass was a dynamic reactive mass, and was almost

completely in tune with the rest of the structure.

(b) Although the response of the structure to the ground excitation would have

three components, one vertical, and two horizontal, the horizontal component

perpendicular to excitation and the vertical component were expected to be

very small as compared to the horizontal component parallel to excitation.

Figures 6.2, 6.3 and 6.4 show that, indeed, the response of the structure was

mainly in the direction of excitation, and the other two components are rela­

tively very small. Before testing, there was a concern about development of a

significant second torsional mode. To control torsion, diagonal braces were

added tothe structure in the direction perpendicular to the direction of exci­

tation.

(c) During testing, it was noticed that the response of the structure included a

minor torsional component. Figure 6.5 shows a comparison of the responses

of the two parallel semi-rigid frames. It can be seen that the two time his­

tories of the two frames are not similar, and that a torsional component is

present. Figure 6.6 shows time histories of the rotational acceleration of the

response of the flexible, semi-rigid, and fixed structures.

6.2.2 Global Response of the Structure

The global response of the structure is presented by the following three plots.

(a) A time history plot of the lateral horizontal drift of the floor in the direction

of excitation. The time history plots in Figure 6.7 indicate that for this case,

the drift response of the three structures; flexible, semi-rigid, and rigid did

not have large variations in amplitude. However, the period of vibration were

dominated by the natural periods of the structures.

-25-

Page 40: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(b) A timE;l history plot of the base shear of the structure. Figure 6.8 shows these

plots. Unlike drift response, the three structures with increasing level of con-

nection stiffness, showed distinctly different base shear responses. As Figure

6.8 indicates, as stiffness of connection increased the base shear value also

increased. Again, because of the dominant first mode of vibration, the fre­

quency of the base ,shear response was governed by the natural frequency of

the structure.

(c) A plot of base shear versus lateral drift, refer to Figure 6.9. This plot is an

indicator of structural stiffness, strength, and energy dissipation characteris-

tics. The following observations could be made

(i) The response of the rigid frame was almost elastic with very small hys­

teresis loops. In addition, the lateral stiffness of the structure was rela­

tively stable and equal to about 22.5 k/in. Maximum values of shear

and drift were 25.88 kips, and 1.22 inches, respectively.

(ii) The semi-rigid frame showed more inelastic hysteresis response than the

rigid structure. However, the stiffness did not show significant deteriora-/

tion. The stiffness was about 13.5 k/in. Maximum values of shear and

drift were 20.00 kips, and 1.41 inches, respectively.

(iii) The response of the flexible frame was significantly nonlinear. The ini­

tial stiffness was about 10.14 k/in., while the stiffness at later cycles was

close to 5.27 k/in.. Maximum values of shear and drift were 9.52 kips

and 1.57 inches, respectively.

(d) A fast Fourier transform was performed on the horizontal response of the

structure, to find its natural frequency of vibrations. Figure 6.10 shows the

FFT for the three structures. The fundamental frequencies of vibration for

the three structures were established at 2 Hz, 2.5 Hz, and 2.87 Hz, respec­

tively. As Figure 6.10 (b) indicates, the semi-rigid frame had a pronounced

-26-

Page 41: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

second mode of vibration at 4.7 Hz. This mode was torsional and is also

shown in Figure 6.6.

6.2.3 Connection Response

Connection forces and deformations, are plotted against each other as listed

below. In the following, connection 4 (N-W) is investigated for the three different

structures.

(a) Axial Force versus Axial Displacement. Figure 6.11 shows typical plots of

axial force versus axial deformation, for the three connections. The following

observations can be made from the experimental data:

(i) In the rigid structure, the connection showed a symmetric axial response

with initial stiffness of about 540 k/in. During large deformations, non­

linearities were observed that are related to cyclic yielding of steel in the

connection area.

(ii) In the semi-rigid connections, Figure 6.11 (b), the response was

significantly unsymmetric. The compressive side response (left half of the

plot) was almost elastic with some nonlinearity for cycles that were pre­

ceded by large tension cycles. However, the tension side of the hysteresis

loops (right half of the plot) showed significant nonlinearity. The non­

linearity is mainly attributed to gap openings due to inelastic deforma­

tion of the connection angles, as shown in Figure 6.12.

(iii) The response of the flexible connection was completely unsymmetric and

nonlinear. The nonlinearity is attributed mainly to two sources: (a) gap

openings due to bending of the outstanding legs of the web angles; and

(b) slip in the bolt holes. It should be mentioned that observation of

connection angles during and after the tests of the flexible frames, clearly

indicated that considerable slip was taking place in bolt holes of back-

-27-

Page 42: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

to-back legs. An examination of web angles after the test indicated

minor hole elongation as well, that might have contributed to develop­

ment of larger slips. The response of the flexible connections showed cer­

tain hardening and increase of axial force, when deformations were large.

The main component of hardening is believed to be kinematic and due

to formation of catenary forces when angle legs undergo large deforma­

tions.

(b) Shear Force versus Shear Deformation. Figure 6.13 shows typical plots of

shear force versus shear deformation, for the three connections. These plots

indicate that the energy dissipation due to shear was more pronounced in the

semi-rigid connections, than in either the flexible or rigid. The approximate

shear stiffness of the connections could be established as 80, 390, and 392

k/in. for flexible, semi-rigid, and fixed connections, respectively.

(c) Moment versus Rotation. Figure 6.14 shows typical plots of moment versus

rotation, for the three connections. In these plots the response resembles very

closely, the lateral load versus lateral displacement response of the three

structures shown in Figure 6.9. The moment-rotation response of the rigid

connection was almost elastic whereas a pronounced" pinching" effect could

be observed in the semi-rigid connection response. In the case of the flexible

connection, large rotations imposed by the column deformation resulted in a

rotation in the opposite direction of the connection moment. Figure 6.15

gives a schematic explanation.

(d) Moment versus Shear. Figure 6.16 shows typical plots of moment versus

shear, for the three connections. I~ this plot, the intent is to demonstrate the

relation between moment and shear, and to see how connection yielding

affects this relationship. The slope in this plot, represents the distance of the

point of inflection of the beam from the center line of the column, in inches.

-28-

Page 43: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Refer to Figure 6.17 for a schematic explanation. The plot of the flexible

connection shows that there was a lot of slippage, and that the point of

inflection moved back and forth in the vicinity of the connection center line.

The plot in the semi-rigid case shows some slippage in the connection, but an

approximate slope of 26 inches is dominant. In the plot for the fixed connec-

tion, the relation between shear and moment is very consistent, and shows a

slope of 27 inches. The irregular behavior that prevails in this plot is due to

the mass slipping at the end of the test. The slope in these plots also

represents the path of the load on the column in the interaction diagram.

(e) Shear versus Rotation. Figure 6.18 shows typical plots of shear versus rota­

tion. For the flexible and most likely in the semi-rigid connections, the shear

force is the major force affecting the behavior of the connection, and not the

moment as in the case of the fixed connection. This type of relation has been

investigated by Astaneh and Nader (15). The slope in the shear-rotation plots

represents the off-diagonal term relating shear to rotation in the 3x3 stiffness

matrix of moment, shear, and axial forces.

where,

[~1-x V WV Y tJW tJ Z

(6.1)

M = moment on the connection

V = shear on the connection

N= axial force on the connection

e - rotation of the connection

~ - shear displacement of the connection

-29-

Page 44: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

a = axial displacement of the connection

To properly understand and represent the behavior of a connection, one

should treat it as a structure and develop the complete 3x3 stiffness matrix as

given by equation (6.1).

6.2.4 Other Significant Responses

Other structural and local parameters that were studied are summarized in

the following section:

(a) The forces in the braces were of interest, because they represent the torsional

. effect on the structure. Figures 6.19, 6.20, and 6.21, clearly indicate that con­

siderable torsional effects were present in the semi-rigid frame. The torsional

mode was also observed in other tests of semi-rigid structure. As noted in

the case of the fixed structure the braces show permanent deformation, also

the time at which the mass slipped can be easily noted.

(b) The deformation of the column during severe dynamic loading was of

interest, so a plot of extreme column deflection with the corresponding forces,

for each of the three structures, is shown in Figure 6.22.

(c) The time history of the moment at the base plate of column 4 for each of the

structures is plotted in Figure 6.23. The base plate moment response was the

same for the three structures. Again the period of vibrations were dominated

by the natural period of the structure. The maximum values of the base plate

moment for the flexible, semi-rigid, and fixed frames were 200.8, 165.9, and

254.9 k-in. respectively. It is believed that the base plate moment of the

semi-rigid structure was less than that of the flexible structure, because of the

slight rocking that was observed in the base plates when the semi-rigid struc­

ture was being tested.

-30-

Page 45: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

6.3 Test Data of the Selected Test Runs

6.3.1 Introduction

In this section, results from representative tests are presented. Table 4.1 pro­

vides information on shaking table tests that were conducted. For each of the

three structures, a free vibration tie-back test was conducted to obtain the

dynamic properties of the structures. The dynamic test runs selected, present the

full range of the experiments. Of the different plots that were presented in previ­

ous section (6.2), a number of plots were found to be necessary to generate for all

the selected tests, mainly:

(1) Connection 4: Moment versus Rotation

(2) Connection 4: Shear versus Rotation

(3) Connection 4: Moment versus Shear

(4) Time history of moment of base plate 4

(5) Plot of the fast Fourier amplitude versus frequency

(6) Time history of the base shear

(7) Time history of the lateral drift

(8) Plot of stiffness

Locations of connection 4 and base plate 4 are shown in Figure 5.5.

6.3.2 Important Observations During Testing

In this part a descriptive behavior of the structure response is given. Each of

the structures was subjected to similar sequences of dynamic loading. The follow­

ing sections give important observations that were noted during the testing of

each of the structures. As the discussion proceeds, the reader is advised to refer to

Tables 4.1, and 4.2.

-31-

Page 46: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(i) Semi-Rigid Frame

The semi-rigid frame was the first structure tested. The initial test was a

Pull-Back test, in which the structure was displaced 0.1 inch, followed by White

Noise Shaking of intensity of O.OSg. The structure response was elastic as

expected, and very small drifts were observed when the White Noise was applied.

White Noise was followed by EI Centro, Taft, and Mexico-City earthquakes,

respectively.

The EI Centro Earthquake was applied with different intensities (0.05g,

0.15g, 0.20g, 0.25g, O.3Sg peak accelerations). In the EI Centro Earthquake series,

the structure behaved almost elastically, and no significant yielding could be

observed, until an intensity of O.35g was applied. The semi-rigid connections did

not experience significant rotation, and behaved almost as fixed connections.

When the 0.3Sg intensity was applied, yielding was observed in all the columns at

the areas immediately beneath the connections. Also, the seated bottom angle in

both south columns showed a slip of about 1/8 inch. Figure 6.24 shows the

observed yielding.

The Taft Earthquake was applied after the EI Centro Earthquake. The

Taft earthquake was also applied with increasing intensities (O.OSg, O.lSg, 0.2Sg,

O.3Sg, O.SOg). At 0.25g peak accelerationvery thin yield lines were observed at the

N-W column at the same location as shown in Figure 6.24. At O.35g peak base

acceleration, the base plates were observed to be slightly rocking, which meant

that the prestressing of the plates to the shaking table was not enough. Also, at

this intensity the torsional mode was clearly apparent. The behavior of the struc­

ture was inelastic at 0.5g, and significant yielding and plastic deformations could

be observed in the same locations as in Figure 6.24.

The Mexico Earthquake was applied with three intensities, O.OSg, O.35g,

O.SOg. At O.3Sg intensity the S-W connection showed clear signs of plastic

-32-

Page 47: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

deformations. The shear connection slipped 3/16 inch, and the top and bottom

seated angles were bent about 1/8 inch in the out-of-plane direction. Figure 6.25

shows the connection. At O.50g the N-W and N-E connections also experienced

plastic deformations similar to the S-W connection, but more pronounced.

(ii) Flexible Frame

Shaking table tests of the flexible frame were conducted after the tests of the

semi-rigid frame. As mentioned in section 4.2 each of the three structures was sub­

jected to the same sequence of dynamic loading.

Tie-back and White Noise: In the pull-back test, higher damping was

observed for the flexible frame compared with that of the semi-rigid frame. The

response of the structure was very flexible when the White Noise was applied.

EI Centro Earthquake: The column deflection under lateral loads was a

single curvature deflection, and not a double curvature as in the case of the semi­

rigid connection. At O.35g intensity significant lateral drift was taking place. Also

the simple connections showed large slippage and almost no yielding, see to Figure

6.26.

Taft Earthquake: No yielding was observed in the structure during this

test even under O.5g intensity. However, ever-increasing slippage took place in the

connections, as the intensity was increased from O.05g to O.5g. The slip in shear

was about 3/16 inch, while the slip in rotation was about 3/32 inch. The bolt

holes on the web of the beam were suspected to be undergoing bearing deforma­

tions.

Mexico Earthquake: The behavior of the structure under the Mexico

Earthquake was very similar to its behavior under the Taft Earthquake.

-33-

Page 48: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(iii) Fixed Frame

The flexible structure tests were followed by the same sequence of tests of the

fixed frame.

Tie-back and White Noise: In the pull-back test, the structure was noted

to have lesser damping and higher natural frequency of vibration.

EI Centro: At O.25g intensity, some yielding was observed at the weld of the

stiffeners in the N-W column at the connection location. At O.35g yielding was

observed in the N-W column, as shown in Figure 6.27.

Taft Earthquake: At O.25g intensity more yielding in all the columns was

noted (Figure 6.27). At O.35g a very loud noise occurred due to slippage of the

concrete blocks acting as the mass. This slip resulted from the very violent

response of the structure. At this point, it was decided to stop the test for the fol­

lowing reasons:

(1) There was concern for the safety of the personnel and instrumentation.

(2) At this point enough data had been collected.

(3) The slip of the mass meant that it was no longer a fully reactive mass.

6.3.3 Tables of Extreme Response Values

The data collected is presented in two forms; first, in the form of tables of

extreme values of various response parameters, and second, in the form of plots

showing variation of important variables.

In Table 6.1, the dynamic properties of the three structures are presented.

These values are determined from the tie-back tests, and thus represent the elas­

tic dynamic properties of the structures.

In Table 6.2 a comparison between the maximum values of the base shear

and lateral drift for flexible, semi-rigid, and fixed structures for different tests, is

-34-

Page 49: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

given.

Tables 6.3 through 6.10 list the maximum values of moment, shear, and

rotation that occurred in connection 4, as well as, the moment of base plate 4.

In Table 6.11 a comparison of stiffnesses of the three structures, subjected to

different earthquakes, is given. Since the behavior of a structure ranges from elas­

tic to inelastic, the stiffnesses recorded vary. To show the range of stiffness, an

elastic stiffness is given, which represents the unloading cycle; followed by an ine­

lastic stiffness, which is the slope of the inelastic portion of the loading branch.

Table 6.12 gives the Fast Fourier Transform reading for the lateral and tor­

sional harmonic periods of vibration of the three structures under different earth­

quake loads.

6.3.4 Description of the Schedule of Plots

As mentioned earlier, only 8 plots were developed for the 24 selected shaking

table tests. These plots are presented in Appendix A. For each of the test runs

the the following plots are presented:

(1) Connection 4: Moment versus Rotation

(2) Connection 4: Shear versus Rotation

(3) Connection 4: Moment versus Shear

(4) Time history of the moment of base plate 4

(5) Time history of the base shear

(6) Time history of the lateral drift

(7) Plot of stiffness

(8) Plot of the fast Fourier amplitude versus frequency

-35-

Page 50: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

CHAPTER SEVEN

SUMMARY AND CONCLUSIONS

The purpose of this investigation was to study and explore the behavior of

flexible and semi-rigid structures under dynamic loading. The potential for using

semi-rigid structures in low seismic zones was the main drive behind this experi­

mental research. Also, the effect of yielding in the connection zones on the

response of different structures was of great interest.

From the data collected and presented in Chapter Six and Appendix A, the

following remarks can be made.

(1) As the stiffness of the connection increased, the base shear resulting from the

same ground motion increased, while the corresponding lateral drift did not

decrease in a similar manner. This type of structural behavior leads to the

idea of optimal design and how it can be approached. To design a structure

to resist a certain dynamic load, one should search for the optimum system

of beam-to-column connections so that the structure would develop the least

possible amount of base shear, and yet not have large lateral deformations.

In this case of a single story structure, having a fixed connection is not the

optimal solution.

(2) To understand and incorporate the real behavior of a connection, a 3x3

stiffness matrix should be established for the connection. This matrix would

relate moment, shear, and axial force to rotation, displacement, and elonga­

tion.

-36-

Page 51: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

(3) Energy can be dissipated in a connection in different ways and not only by

moment-rotation hysteresis loops. The energy can also be dissipated by axial

force - axial displacement hysteresis loops, and shear force - shear displace­

ment hysteresis loops.

(4) Changing the connection type in a structure can drastically change the

response characteristics of the structure. This was demonstrated when the

torsional mode was actually excited in the case of the semi-rigid structure,

although it was not as apparent in the other two types of structures.

(5) The semi-rigid connections behaved almost as a rigid connection in most of

the dynamic tests. The moment capacity of the semi-rigid connections turned

out to be higher than expected. The catenary forces that were developed in

the seated connections, could double the expected plastic moment of such

connections. Semi-rigid connections have considerable potential for resisting

earthquake loading, and need further study.

Need for Further Research

As can be noted from the experimental results presented in this report, flexi­

ble and semi-rigid connections have considerable potential for resisting dynamic

loading in low to medium earthquake zones. The behavior of such connections

can drastically change the response of a structure. To understand how such con­

nections can be used in optimal design of structural systems, more research is

needed. The research should include testing structures with more degrees of free­

dom and various configurations of connections. It is also necessary to include

non-structural elements in the structure under investigation.

-37-

Page 52: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

References

[1] Krawinkler, H., and Popov, E. P. (1982). "Seismic behavior of moment con­nections and joints." J. Struct. Engrg., ASCE, 108(2), 372-391.

[2] Popov, E. P., and Pinkney, R. B. (1969). "Cyclic yield reversal in steel build­ing connections." J. Struct. Engrg., ASCE, 95(ST#), 327-353.

[3] Stelmack, T. W., Marley, M. J., and Gerstle, K. H. (1986). "Analysis andtests of flexibly connected steel frames." J. Struct. Engrg., ASCE, 112(7),1573-1586.

[4] Stelmack, T. W. (1983). "Analytical and experimental response of flexibly­connected steel frames. ' Report to AlSI CEAE Dept., Univ. of Colorado,Boulder, Colo.

[5] Azizinamini, A., Bradburn, J. R.,and Radziminski, J. B. (1985). "Static and-Cyclic behavior of semi-rigid steel beam-column connections." Dept. of Cic.Engrg., Univ. of South Carolina, Columbia, S.C.

[6] Frye, M. J., and Morris, G. A. (1975). "Analysis of flexibly connected steelframes." Can. J. Civ. Engrg., 2, 280-291.

[7] Goverdhan, A. V. (1983). "A collection of experimental moment-rotationcurves and evaluation of prediction equations for semi-rigid connections."Thesis presented to Vanderbilt University, at Nashville, Tenn., in partialfulfillment of the requirements for the degree of masters of science.

[8] Kishi, N., and Chen, W. F. (1986)."Steel connection data bank program."CE-STR-86-26, School of Civ. Engrg., Purdue Univ., W. Lafayette, Ind.

[9] Kishi, N., et al. (1987). ''Moment-rotation relation of top- and bottom seat­angle with double web-angle connections." CE-STR-87-16, School of Civ.Engrg., Purdue Univ., W. Lafayette, Ind. (Proc. of the State-of-the-ArtWorkshop on Connections and the Behavior, Strength and Design of SteelStructures, R. Bjorhovde, J. Brozzetti, and A. Colson, eds., Ecole NormaleSuperieure de Cachan, France, May 25-27, 1987).

[10] Kishi, N., et al. (1987). ''Moment-rotation relation of single/double web-angleconnections." CE-STR-87-18, School of Civ. Engrg., Purdue Univ., W. Lafay­ette, Ind. (Proc. of the State-of-the-Art Workshop on Connections and theBehavior, Strength and Design of Steel Structures, R. Bjorhovde, J. Brozzetti,and A. Colson, eds., Ecole Normale Superieure de Cachan, France, May 25­27, 1987).

[11] Hwang, J. S., Chang, K. C., Lee, G. C'l Ketter, R. L. (1988). "Shaking tabletests of a pinned-base steel gable frame. ' Dept. of Civ. Engrg. State Univ. ofNew York at Buffalo.

-38-

Page 53: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

[12] Shing, B., Gerstle, K., and Harsoyo, (1989). "Seismic response of FlexiblyConnected Steel Frames," Proceedings of The Session Related to Steel Struc­tures, ASCE Structures Congress, San Francisco 1989.

[13] Leon T. R., (1987). "Semi-Rigid Composite Steel Frames," Proceedings, AISCNational Engineering Conference, New Orleans,1987.

[14] Whttaker, A. S., Uang, C.-M.,and Bertero, V. V.. " An Experimental Studyof The Behavior of Dual Steel Systems," UCB/EERC-88/14,Sept., 1988.

[15} Astaneh, A. and Nader, M., " Behavior and Design of Steel Tee FramingConnections," Report No. UCB/SEMM-88/11, Department of Civil Engineer­ing, University of California, Berkeley, July 1988.

[16} Uniform Building Code. ''International Conference of Building Officials,"Whittier, California, 1988.

[17} 8th Edition, American Institute of Steel Construction, Chicago, 1980.

[18] Rea, D., and Penzien, J., "Structural Research Using an Earthquake Simula­tor," Proceedings, Structural Engineers Association of California,October,1972.

[19] Becker, A. R., and Chambers, M. J., "s, An Interactive Environment ForData Analysis and Graphics,".

-39-

Page 54: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 2.1. Section Properties

SECTION PROPERTIES

FRAME MEMBERS I TRANSVERSE MEMBERS

PROPERTIES Column Girder Channel Bracing

W4x13 W10x15 C9x15 L2x2x1/4

A (in2 ) 3.83 4.41 4.41 0.94

d (in) 4.16 9.99 9.00 2.00

t w (in) 0.28 0.23 0.29 0.25

bf (in) 4.06 4.00 2.49 2.00

tf (in) 0.35 0.27 0.41 0.25

wt /ft (#/ft) 13.00 15.00 15.00 3.19

Ixx (in4 ) 11.30 68.90 51.00 0.35

Sx (in3 ) 5.46 13.80 11.30 0.25

Iyy (in4 ) 3.86 2.89 1.93 0.35

Sx (in3 ) 1.90 1.45 1.01 0.25

J (in4 ) 0.15 0.10 ... ...Zx (in3 ) 6.28 16.00 ... ...Zy (in3 ) 2.92 2.30 ... ...

-40-

Page 55: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 2.2. Weight of the Structure

WEIGHT OF STRUCTURE

MemberWeight/foot Length * Weight

(lbs/ft) (feet) (lbs)

Column 13.0 13.33 173.3

Beam 15.0 11.20 168.0

Channel 15.0 18.70 280.5

Bracing 3.2 22.40 71.7

Connections ... ... 30.0

Floor ... ... 2300.0Diaphragm

Added Mass ... ... 24400.0

TOTAL WEIGHT - 27423.5

* length included for columns and diagonal bracings are from mid height of structure to floor level

-41-

Page 56: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 3.1. Allocation of Various Transducers to Specific Channels

CHANNEL ALLOCATIONCHANNEL # NAME UNITS

1 Horizontal Disp.l inches2 Horizontal Disp.2 inches3 Av. Horizontal Ace. g's4 Av. Vertical Ace. g's5 Pitch Acceleration radjsec2

6 Roll Acceleration radjsec2

7 not activated ...8 Vertical Disp.l inches9 Vertical Disp.2 inches

10 Vertical Disp.3 inches11 Horizantal Velocity inches/sec

Channels 12 through 25 were not activated

26 Accelerometer 1 g's27 Accelerometer 2 g's28 Accelerometer 3 g's29 Accelerometer 4 g's30 Accelerometer 5 g'S

Channels 31 through 33 were .not activated

34 DCDT 1 inches35 DCDT 2 inches36 DCDT3 inches37 DCDT4 inches38 DCDT5 inches39 DCDT6 inches40 DCDT 7 inches41 DCDT8 inches42 DCDT9 inches43 DCDT 10 inches44 DCDT 11 inches45 DCDT 12 inches46 DCDT 13 inches47 DCDT 14 inches48 DCDT 15 inches49 DSDT 16 inches50 Potentiometer 1 inches51 Potentiometer 2 inches52 Potentiometer 3 inches53 Potentiometer 4 inches54 Potentiometer 5 inches55 Potentiometer 6 inches56 Potentiometer 7 inches57 Potentiometer 8 inches58 Potentiometer 9 inches59 Strain Gage 10 mstrain60 Strain Gage 11 mstrain

-42-

CHANNEL ALLOCATIONCHANNEL # NAME UNITS

61 Strain Gage 12 mstrain62 Strain Gage 13 mstrain63 Strain Gage 14 mstrain64 Strain Gage 15 mstrain65 Strain Gage 16 mstrain66 Strain Gage 17 mstrain67 Strain Gage 18 mstrain68 Strain Gage 19 mstrain69 Strain Gage 20 mstrain70 Strain Gage 21 mstrain71 Strain Gage 22 mstrain72 Strain Gage 23 mstrain73 Strain Gage 24 mstrain74 Strain Gage 25 mstrain75 Strain Gage 26 mstrain76 Strain Gage 27 mstrain77 Strain Gage 28 mstrain78 Strain Gage 29 mstrain79 Strain Gage 30 mstrain80 Strain Gage 31 mstrain81 Strain Gage 32 mstrain82 Strain Gage 33 mstrain83 Strain Gage 34 mstrain84 Strain Gage 35 mstrain85 Strain Gage 36 mstrain86 Strain Gage 37 mstrain87 Strain Gage 38 mstrain88 Strain Gage 39 mstrain89 Strain Gage 40 mstrain90 Strain Gage 41 mstrain91 Strain Gage 42 mstrain92 Strain Gage 43 mstrain93 Strain Gage 44 mstrain94 Strain Gage 45 mstrain95 Strain Gage 46 mstrain96 Strain Gage 47 mstrain97 Strain Gage 48 mstrain98 Strain Gage 49 mstrain99 Strain Gage 51 mstrain

100 Strain Gage 52 mstrain101 Strain Gage 53 mstrain102 Strain Gage 54 mstrain103 Strain Gage 55 mstrain104 Strain Gage 56 mstrain105 Strain Gage 57 mstrain106 Strain Gal!:e 58 mstrain

Page 57: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Table 4.l.a. Sequence of Testing

SEQUENCE OF TESTING

Semi-Rigid Connection

EXCITATION DURATIONREMARKS

RATEFILENAME of SIGNAL

SIGNAL ** INTERVALSPAN ***

(sec) (sec) (sec)

880705.01 * f.v. 20 .005 ... ...880705.02 r.30.d 35 .005 ... 250

880705.03 ec2 35 .005 0.02 55

880705.04 * ec2 35 .005 0.02 110

880705.05 ec2 35 .005 0.02 275

880705.06 * ec2 35 .005 0.02 362

880705.07 * ec2 35 .005 0.02 551

880705.08 r.30.d 35 .005 ... 110

880705.09 taft2 35 .005 0.02 104

880705.10 * taft2 35 .005 0.02 312

880705.11 taft2 35 .005 0.02 520

880705.12 * taft2 35 .005 0.02 758

880705.13 * taft2 35 .005 0.02 1000

880705.14 sct.o 13 .005 0.0035 50

880705.15 * sct.o 13 .005 0.0035 116

880705.16 * sct.o 13 .005 0.0035 166

* selected tests reported here

** f.v. = Free Vibration

r.30.d = Random White Noise

ec2 = El-Centro SOOE Earthquake

taft2 = Taft N21E Earthquake

sct.O = SCT S60E Mexico City Earthquake

*** a span of 1000 corresponds to 5 inches of shaking table displacement

-43-

Page 58: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 4.l.b. Sequence of Testing

SEQUENCE OF TESTING

Flexible Connection

EXCITATION DURATIONREMARKS

RATEFILENAME of SIGNAL

SIGNAL ** INTERVALSPAN ***

(sec) (sec) (sec)

880706.01 f.v. 20 .005 ... ...880706.02 r.30.d 35 .005 ... 250

880706.03 ec2 35 .005 0.02 55

880706.04 ec2 35 .005 0.02 110

Retightened the prestress rods attached to the base plates to 60 ksi.

880706.05 * f.v. 20 .005 ... ...880706.06 r.30.d 35 .005 ... 110

880706.07 ec2 35 .005 0.02 55

880706.08 * ec2 35 .005 0.02 110

880706.09 ec2 35 .005 0.02 275

880706.10 * ec2 35 .005 0.02 362

880706.11 * ec2 35 .005 0.02 551

880706.12 r.30.d 35 .005 ... 110

880706.13 taft2 35 .005 0.02 104

880706.14 * taft2 35 .005 0.02 312

880706.15 taft2 35 .005 0.02 520

880706.16 * taft2 35 .005 0.02 758

880706.17 * taft2 35 .005 0.02 1000

880706.18 sct.o 13 .005 0.0035 50

880706.19 * sct.o 13 .005 0.0035 116

880706.20 * sct.o 13· .005 0.0035 166

* selected tests reported here

** same notation are used as in Table 4.1.a

*** a span of 1000 corresponds to 5 inches of shaking table displacement

-44-

Page 59: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 4.l.c. Sequence of Testing

SEQUENCE OF TESTING

Fixed Connection

EXCITATION DURATIONREMARKS

RATEFILENAME of SIGNAL

SIGNAL ** INTERVALSPAN ***

(sec) (sec) (sec)

880707.01 * f.v. 20 .005 ... ...880707.02 r.30.d 35 .005 ... 250

880707.03 ec2 35 .005 0.02 55

880707.04 * ec2 35 .005 0.02 110

880707.05 ec2 35 .005 0.02 275

880707.06 * ec2 35 .005 0.02 362

880707.07 * ec2 35 .005 0.02 551

880707.08 r.30.d 35 .005 ... 250

880707.09 taft2 35 .005 0.02 104

880707.10 * taft2 35 .005 0.02 312

880707.11 taft2 35 .005 0.02 520

880707.12 * taft2 35 .005 0.02 758

* selected tests reported here

** f.Y. = Free Vibration

r.30.d = Random White Noise

ec2 = EI-Centro SOOE Earthquake

taft2 = Taft N21E Earthquake

sct.O = SCT S60E Mexico City Earthquake

*** a span of 1000 corresponds to 5 inches of shaking table displacemrnt

-45-

Page 60: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Table 4.2. Contents of Magnetic Tapes

Which Save the Data

CONTENTS OF TAPES

Tape 1 Tape 2

Semi-rigid Flexible Fixed

880701.01 * 880706.01 880707.01

880701.02 * 880706.02 880707.02

880701.03 * 880706.03 880707.03

880701.04 * 880706.04 880707.04

880701.05 * 880706.05 880707.05

880705.01 880706.06 880707.06

880705.02 1/ 880706.07 880707.07

880705.03 880706.08 880707.08

880705.04 880706.09 880707.09

880705.05 880706.10 880707.10

880705.06 880706.11 880707.11

880705.07 880706.12 880707.12

880705.08 880706.13

880705.09 880706.14 .

880705.10 880706.15

880705.11 880706.16

880705.12 880706.17

880705.13 880706.18

880705.14 880706.19

880705.15 880706.20

880705.16

* pre! iminary tests with load cells

-46-

Page 61: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.1. Elastic Dynamic Properties

FREE VIBRATION

Damping Period of Vibration (sec)Structure

(%) FFT Cycles/time

Flexible 1.87 0.44 0.44

Semi-rigid 0.50 0.33 0.31

Fixed 0.67 0.30 0.31

TABLE 6.2. Base Shear and Lateral Drift

MAXIMUM VALVES OF BASE SHEAR AND LATERAL DRIFT

Earthquake Flexible Semi-rigid Fixed

Structure Structure StructureSignal and

Shear Drift Shear Drift Shear DriftIntensity

(kips) (in.) (kips) (in.) (kips) (in.)

EI-Centro 0.15g 4.14 0.42 4.62 0.20 5.40 0.23

EI-Centro 0.25g 8.10 1.09 11.76 0.56 14.95 0.61

EI-Centro 0.35g 10.00 2.08 18.81 1.15 18.12 0.82

Taft 0.15g 5.35 0.61 9.14 0.55 16.82 0.60

Taft 0.35g 9.52 1.57· 20.00 1.41 25.88 1.22

Taft 0.50g 11.49 2.00 24.28 2.35 N.C N.C

Mexico 0.35g 9.22 1.45 21.2 2.00 N.C N.C

Mexico 0.50g 12.26 2.05 22.26 2.30 N.C N.C

N.C = test was not conducted

-47-

Page 62: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.3. Extreme Response Values For O.15g El Centro

O.15g EI .. Centro Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *14.0 44.1 48.5

(k-in.)

Connection Shear *1.08 1.94 1.90

(kips)

Connection Rotation *0.0071 0.0007 0.0006

(radians)

Base Moment (k-in) ** 77.3 51.2 57.8

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

TABLE 6.4. Extreme Response Values For O.25g EI-Centro

O.25g EI Centro Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *33.9 123.2 146.0

(k-in.)

Connection Shear *2.16 4.61 4.59

(kips)

Connection Rotation *0.022 0.0020 0.0016

(radians)

Base Moment (k-in) ** 166.9 123.6 151.4

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

-48-

Page 63: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.5. Extreme Response Values For O.S5g El,Centro

O.S5g EI Centro Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *112.5 183.8 175.9

(k-in.)

Connection Shear *2.11 7.34 5.62

(kips)

Connection Rotation *0.040 0.008 0.0018

(radians)

Base Moment (k-in) ** 247.6 214.3 167.7

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

TABLE 6.6. Extreme Response Values For O.15g Taft

O.15g Taft Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *27.4 107.5 161.2

(k-in. )

Connection Shear *1.34 4.25 5.50

(kips)

Connection Rotation *0.015 0.003 0.0018

(radians)

Base Moment (k-in) ** 111.9 101.4 152.9

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

-49-

Page 64: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.7. Extreme Response Values For O.35g Taft

O.35g Taft Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *44.6 200.7 251.2

(k-in.)

Connection Shear *1.93 7.86 11.97

(kips)

Connection Rotation *0.026 0.008 0.0033

(radians)

Base Moment (k-in) ** 200.8 165.9 254.9

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

TABLE 6.8. Extreme Response Values For O.50g Taft

O.50g Taft Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *59.5 228.0 N.C

(k-in.)

Connection Shear *2.47 8.70 N.C

(kips)

Connection Rotation *0.037 0.031 N.C

(radians)

Base Moment (k-in) ** 239.9 292.0 N.C

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

N.C = test was not conducted

-50-

Page 65: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.9. Extreme Response Values For 0.35g Mexico

0.35g Mexico Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *40.8 203.2 N.C

(k-in.)

Connection Shear *1.58 7.67 N.C

(kips)

Connection Rotation *0.027 0.024 N.C

(radians)

Base Moment (k-in) ** 196.4 238.7 N.C

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

N.C = test was not conducted

TABLE 6.10. Extreme Response Values For 0.50g Mexico

0.50g Mexico Earthquake

Variable Flexible Semi-rigid Fixed

Connection Moment *59.5 225.6 N.C

(k-in.)

Connection Shear *2.26 9.46 N.C

(kips)

Connection Rotation *0.033 0.030 N.C

(radians)

Base Moment (k-in) ** 253.6 281.0 N.C

* Moment, shear, and rotation for connection # 1

** Moment for base plate # 1

N.C = test was not conducted

-51-

Page 66: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.11. Structure Stiffnesses

STIFFNESS OF THE THREE STRUCTURES

Earthquake Flexible Semi-rigid Fixed

Structure Structure StructureSignal and

Elastic Inelastic Elastic Inelastic Elastic Inelastic

Intensity Unloading' ''Loading' Unloading' ''Loading' Unloading' 'Loading'

(k/in) (k/in) (k/in) (k/in) (k/in) (k/in)

EI-Centro 0.15g 10.33 10.33 22.57 22.57 25.2 25.2

EI-Centro 0.25g 10.33 6.49 23.14 19.06 24.0 24.0

EI-Centro 0.35g 7.77 4.30 19.81 16.1 23.5 23.5

Taft 0.15g 9.88 7.43 17.46 17.46 24.05 24.05

Taft a.35g 10.14 5.27 14.58 12.4 23.65 21.38

Taft 0.50g 8.16 5.21 18.00 13.20 N.C N.C

Mexico 0.35g 8.47 5.42 18.38 8.38 N.C N.C

Mexico a.50g 9.62 5.39 16.81 7.61 N.C N.C

N.C = test was not conducted

-52-

Page 67: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE 6.12. Natural Periods of Vibration

PERIODS OF VIBRATION USING FFT *

Earthquake Flexible Semi-rigid Fixed

Structure Structure StructureSignal and

Lateral Torsional Lateral Torsional Lateral TorsionalIntensity

(sec) (sec) (sec) (sec) (sec) (sec)

EI-Centro 0.15g 0,47 0.23 0.33 0.17 0.36 0.17

EI-Centro 0.25g 0,48 0.24 0.35 0.19 0.38 0.18

EI-Centro 0.35g 0.52 0.23 0.35 0.19 0.38 0.17

Taft 0.15g 0,48 0.22 0,40 0.20 0.32 0.17

Taft 0.35g 0.50 0.25 0,40 0.21 0.36 0.18

Taft 0.50g 0.53 0.25 0,46 0.23 N.C N.C

Mexico 0.35g 0,49 0.25 0,48 0.22 N.C N.C

Mexico 0.50g 0.53 0.25 0.44 0.25 N.C N.C

N.C = test was not conducted

-53-

Page 68: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TEST STRUCTURE

__B_AS_E_E_X_C_IT:_T_IO_~_D_IR_E_C_T_IO_N /

Figure 1.1 Test Structure

Figure 2.1 Test Structure Mounted on the Shaking Table

-54-

Page 69: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Weight

e- li II iI c-

..,m /~

f-

W 10X15 /

/.Connection

Beam

~"-.

W 4X13 10IColumn __ (0

FixedBase Plate

""~ - '-., ~ ~

Base Acceleration

~ .... ~6'-0">------

Weight

•• •••• •••• •••• ••

/C9x15

/L2x2x1/4

~"-.

W 4X13 10

'"Column

I(0

FixedBase Plate

~ •

~ g'-O" ~BRACING

Figure 2.2 Dimensions of the Test Structure

-55-

Page 70: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

1/2" E70-XX Fillet Welds

"

Floor Diaphragmto Support Added Mass

~

- / - 6.5"

-

~ 1Wl0 15~2X6X1/2"~Ubes connect~B

x welded to the sideeam . /2'" .with 1 reinforcing plate

-

7.5"

-+ 20.5" ~r---_1_7'_'-----.1__1_7_,._.---+,--_2_0._5'_'----'T-

Figure 2.3 Floor System and Floor-to-Beam

Connection Detail

-56-

Page 71: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

4.16"

A325 1/2" bolts

at 1.5" c-c spacing

2L2x2x3/16"

++W4x13 0.5"Column

10"

W10x15

Beam

Figure 2.4 Flexible Connection Detail

-57-Reproduced frombest available copy.

Page 72: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

4.16"

W4x13Column

++0.5"

A325 1/2" bolts

at 1.5" c-c spacing

2L2x2x3/16"

L2x3-1/2x3/16"

1A"

W10x15

Beam

Figure 2.5 Semi-Rigid Connection Detail

-58-

Page 73: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

4.16"

W4x13Column

/ -++Stiffeners 0.5"

E70XX Welds

A325 1/2" bolts

at 1.5" c-c spacing

E70XX Welds

2L2x2x3/16"

10"

W10x15

Beam

Figure 2.6 Fixed Connection Detail

-59-

Page 74: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

W4x13 Column

Triangular Plate

4-A490 bolts

11 11

+1-3/411

\'----1OIlX 10"

Base Plate

Prestressingto Shaking

Table (60ksi)

Figure 2.7 Base Plate Detail

-60-

Page 75: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

II

•II

Mass C.G

/::a: e= 1.25 11

"Floor C.L

6'-011

-+-----~--=----tt_

Figure 2.8 Added Mass on Structure

II II

Cable Attachedto Crane

IIII

IIII 12 1 x12"

Timber Beams

o

Figure 2.9 Safety Considerations

-61-

Page 76: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

s

, 9'+

I IAcc.5

E321

• 6' W

-tAcC

3Acc.1 ±

Acc.2

N

( Elevation == 8:5.75" )

g'+.......----------i

6' Acc.4 4

Floor diaphragm

(89.5" elevation)

Figure 3.1 Location of Accelerometers

-62-

Page 77: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

E

Potentiometers

s

w

N

Floor Diaphragm Floor Diaphragm

~ pot6 ~ pot92411

2411

• pot5 •22 11

pot4pot8

•20 11 pot3

• 64 11

20 11 pot2• pot1

pot71211

• •11.5 11 11.511

S-W Column S-E Column

Figure 3.2 Location of Potentiometers

-63-

Page 78: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

/2 111 DCDT'sd1

r! 3.5"

••h ••

'1 3.5"

d2

2 111 DCDT's

W4x13 Column +-+ 0.511 DCDT1.2511

Figure 3.3 Method of Measuring Connection Rotation

I IDCDI's 11 to 15 DCDI's 1 to 5

IDCDT 16

tN

IDCDI's 6 to 10

Figure 3.4 Location of DCDT's

-64-

Page 79: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

29 28 27 26 19 18 17 16

20 21 22 23 10 11 12 13

•39 J8 37 36 N -49 -48 -47 -46

30 31 32 33 40 41 42 43

The Strain Gages are at 24" from the Top of the Base Plate

Figure 3.5 Location of Strain Gages on Columns

-65-

Page 80: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Weight

••••••••

sg56

Brace4

I 9'-0"1f.-----South Side Bracing

note: Strain Gages are at 26" from edge of column

Weight

••••••••

sg52

Brace 1

I 9'-0" I1.....--------f-North Side Bracing

note: Strain Gages are at 26" from edge of column

Figure 3.6 Location of Strain Gages on Diagonal Bracings

-66-

Page 81: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

0.6

0.4

0.15q ELCENTRO

0.:1

-0.:1

0.25q ELCENTROAcC 0.:1e1era o. 0 t---+ttHIhJH*'Ht:p.Ill~"""'~~/\fr.ilH+-f.lf~IfJcrI~W~~Nl\,AA~IN~~~I'Itfo~Nl-I+--------~tion'-0.:1

G.s

0.35q ELCENTRO

0.2

- 0.:1

-0.4

-0.6

o 10 :10

TIME, sec

30 40

Figure 4.1 Acceleration Time History of EI Centro Earthquake

-67-

Page 82: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

0.15

0.4

0.2

0.159' TAFT

-o.a

0.35q TAFT

AcC 0.2e1era o. 0 I--JI/ItII/Ut:ion, -0.2

G,

0.0

II

.., ~I--_~~

-0.2

-0.4

-0.15

0.50q TAFT

o 10 20

TIME, sec

30 40

Figure 4.2 Acceleration Time History of Taft Earthquake

-68-

Page 83: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

0.6

0.4

0.359 MEXICO

AcC 0.:2e1era o. 0 1------¥T+~___h.J+_H_+_+f+_i_+_t_iH_'I+\H_+++t_+t++_H+H_+++++t_t++_+_+_'<f+_+_"'_-----_ition, -0.:2

G,s

-0.4

-0.6

0.6

0.4

AcC 0.:2e1era 0.0tion, -0.:2

G,s

-0.4

-0.6

l-

I-

0.50g MEXICO

l-

N J ~

J\ " 1I1~ t\

A n Art ~ AM~AfI~v ~ ~ V \.,

V~ V\vVv'V'vi

l-

I-

l-

Ii I I I I I I I I I I I I

o 1 2 4 5 6

TIME, sec

8 9 10 11 12 13

Figure 4.3 Acceleration Time History of Mexico Earthquake

Page 84: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

O.35g MEXICO

0.07 ,--------------------------------------------,

0.06 -

0.05 -

r0uRt 0.04 -ER

AMP}:. 0.03 -ITUDE

0.01 f-

0.01 f-

~~O. 0 lf~~''~fIT~'~'r~==:±:==±===±:===::1:===:±===l::=:==±===±==d

o 10 20 30 40 50

FREQUENCY ,hertz

60 70 80 90 100

Figure 5.1 Fast Fourier Transform of a Typical Shaking Table

Ground Motion Input

-7~

Page 85: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

1 Before Applicationof Lowpass Filter

Acce1 -1erati0n

0f

F10

0r

Le

After Applicationv1 of Lowpass Filtere

1

G

s

0

-1

10o

-2 L __-L L-.__-l.-__---l --L--'--_---.L ..L..-__~

30 .0

'lIMB, ••a0.359 TAr!

Figure 5.2 Typical Time History of Floor Acceleration Response before

and after the Ormsby Lowpass Filter was applied

-71-

Page 86: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

e e

U1North '" Col. Col.ro

~ 3,4 1,2

D +ve....

South

POSITIVE SIGN CONVENTION

Figure 5.3 Global Sign Convention

~S

~MConnections

3 and 4

V M

+)M V( +. _...C.. :

e I

S~

~M

Connections1 and 2

POSITIVE SIGN CONVENTION

Figure 5.4 Connection Sign Convention

-72-

Page 87: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

2 s 1

E w

3N

4

Figure 5.5 Member Designations

-73-

Page 88: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

-30

Using

Strain Gages

24.2 Klin

FIXED FRAME

Using

Accelerometers

23.5 klin

-1 oLATERAL DRIFT, inches

0.159 TAFT

-1 o 1

Figure 5.6(a) Comparison of Stiffness Calculated by Strain

Gages and Accelerometers

-74-

Page 89: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

20

Using Strain GagesB 10

A5E

5H

~ 0 }--_....,..I\N\:!1F'R

-20

20

B 10A5E

5H

~01---...1'!I'rA'n'WI~R

-20

L

Using Accelerometers

o 10 20

TIME, secO.ISg TAFT

30 40

Figure 5.6(b) Time History Comparison of Base Shear Calculated

by Strain Gages and Accelerometers

-75-

Page 90: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Accelerometer 4 (Added Mass Acc.)

Acce1eration

G

s

-1

/\

Accelerometer 1 (Floor Acc. )

SEMI-RIGID FRAME

-2 tt:.. ...L -L -L ----.1 --l L.... .L- ----'

o 10 20

TIMI:, sec0.359' TAFT

30 40

Figure 6.1 Time Histories of Floor Acceleration and

Added Mass acceleration

-76-

Page 91: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Acce1eration

G

s

1

-1

-2

FLEXIBLE FRAME

Excitation Direction

Transverse Direction

Vertical Direction

o 10 20

TIME, secO,3Sq TAFT

30 40

Figure 6.2 Acceleration Time History of Different Components of the

Response of the Flexi ble Structure

-77-

Page 92: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

1 Excitation Direction

Transverse Direction

Acce1eration

G

s

-1Vertical Direction

o~-----__~_~_~~__~_~ ~ _

-1

40302010o-2 tt:...----..l.------L-----L ---L -l.. --l. --l --l

'lIME, sec0.35, 1'APT

Figure 6.3 Acceleration Time History of Different Components of the­

Response of the Semi-Rigid Structure

-78-

Page 93: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

Excitation Direction

1 1- Transverse DirectionACce1erat 0

i0

n

G

s

-1 vertical Direction

-1

-2 tl::.- ...L -L --.L --l --.J:.-.. L-- ..L- ---'

o 10 20

TIME, sec0.35'1 TAFT

30 40

Figure 6.4 Acceleration Time History of Different Components of the

Response of the Fixed Structure

-79-

Page 94: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

4 f-

2 I-

West Frame

La -2 l-tera1

DisP1acement

inches

·vv

East Frame

-2

-4 =- ----L.. .l.- ----L..__---'_.l.- ---L .L- -L ---J

o 10

TIME, sec0.359 TAPT

30 40

Figure 6.5 Comparison of Displacement Time History of the

Two Parallel Frames

-80-

Page 95: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FlEXIBLE FRAME

0

R

, ~0tati0na

SEMI-RIGID FRAME1

Acce1 0erati0n -2

Rad/

, ~se

FIXED FRAMEc2

-2

-4

-6

o 10 20 30 40

TIME, sec0.35'1 TAFT

Figure 6.6 Rotational Acceleration Time History for Flexible,

Semi-Rigid, and Fixed Structures

-81-

Page 96: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

6

4

FLEXIBLE FRAME

2

-2

LATERA 2L

DI5pLA 0CEMENT

i -2nches

2

'"Max Drift ~ 2.15%

SEMI-RIGID FRAME

'-Max Drift - 1.94'

FIXED FRAME

-2

-4

Note: DRIFT- DIL

~ Max Drift - 1. 68%D

-6 1L .l...- .L- L- ---...Il.- -l ---L --'- -'

o 10 20

TIME, sec0.35'1 TAFT

30 40

Figure 6.7 Time History of Floor Lateral Drift of Flexible,

Semi-Rigid, and Fixed Structures

-82-

Page 97: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

B 10

ASE

SHEAR

20 I-

FLEXIBLE FRAME

------- Max Shear - 9.5 kips

B 10 I-

SEMI-RIGID FRAMEAsE

s,d.H

~ #\~hn~~H

EA ·VVVVV~ I~VVVVR

kiP5-10 I-

-20 r

20

Max Shear - 20.0 kips

FIXED FRAME

B 10

ASE

SHEAR

v

-20

Max Shear - 25.9 kips

-.,.D

W

Note:, w- 27.42 Kips ~

Floor Acceleration - «Base Shear)/ W )* 9-30

o 10 20

TIME, sec0.35g TAFT

30 40

Figure 6.8 Time History of Base Shear for Flexible, Semi-Rigid,

and Fixed Structures

-83-

Page 98: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

v...

25.9 kips1. 22 in

FRAME lri:

SEMI-RIGID FRAME

IV- 20.0 kip!>D- 1.4l. in

1-- D

~~

FLEXIBLE FRAME

~ Iv- 9.52 kipsD- 1. 57 in

-20

5H

~Ol--------------------R

20

30

B 10

A5E

-30 t=... ...L.. -.L ----l L- ..L- _

-4 -2 o

LATERAL DRIFT, inches0.359 TAFT

Figure 6.9 Comparison of Stiffness of Flexible, Semi-Rigid,

and Fixed Structures

-84-

Page 99: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

0.07

FLEXIBLE FRAME

0.20

SEMI-RIGID FRAME

0.20

FIXED FRAME

0.06

0.15 I- 0.15

F0.05

0U

rie 0.04r

A 2 Hz 0.10 ,...:. 2.5 Hz 0.10 2.77 Hzm

P 4.76 Hz1 0.03itude

0.02

0.05 - 0.05

0.01

0.0 ~I " 110.0 0.0

0 10 20 0 10 20 0 10 20

(a) (b) (e)

FRI!:OUENCY,hertz0.35g TAFT

Figure 6.10 Typical Fast Fourier Transform of The Response

of Flexible, Semi-Rigid, and Fixed Structures.

-85-

Page 100: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

10

1\XI1\L

FoR 0r.E

ItiPs

-5

-10

FIXED FRAME

1SEMI-RIGID FRAME

210 k/in

j440 k/in

-0.025 0.0

AXIAL DEPORMATION, inches0.359 TAFT

(al

0.025 -0.025 0.0

AXIAL DEFORMATION, inch.s0.359 TAFT

(b)

0.025

FLEXIBLE FRAME

1\XI1\L

FoR 0CE

Itips

-5

~85 k/in

840 k/in

-0.3 -0.05 -0.025 0.0

AXIAL DEFORMATION, inches0.359 TAFT

(el

0.025 0.05 0.3

Figure 6.11 Axial Force versus Axial Deformation of Connection =IF 4

-86-

Page 101: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

W4X13

Column

Axial Force

Gap Openings

..Axial Force

~AngleS

Figure 6.12 Inelastic Deformation of the

Connection Angles

-87-

Page 102: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

S 5HEAR

FoR 0CE

kips -5

~FLEXIBLE FRAME

80 k/in

10

/S 5HEAR

FoR 0CE

kips -5

SEMI-RIGID FRAME

0.10 .

FIXED FRAME

0.050.0-0.05

-10 ;:'0k/in

18

-10

-0.10

kips -5

FoR 0CE

S 5HEAR

-15

SHEAR DEFORMATION, inches0.359 TAFT

Figure 6.13 Shear Force versus Shear Deformation of Connection # 4

-88-

Page 103: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

ItIN

-100

-200L

-300

FIXED FRAME

I

~69200 k-injrad

I I

30600

SEMI-RIGID FRAME

/

Jk-injraa

200

-0.02 0.0

ROTATION, rad0.359 TAFT

(I. 02

FLEXIBLE FRAME

-0.02 0.0

ROTATION, rad0.359 TAFT

0.02

100

MoKENT 0

ItIN

-100

7600 k-in/rad

-200

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.359 TAFT

Figure 6.14 Moment versus Rotation of Connection =#= 4

-89-

Page 104: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

M'- .......

/ "-/ "-

/ .........

II

/

The plastic moment decreasesas the rotation increases dueto loss of stiffness

cycle 1J cyclic loading

, envelope

e

Figure 6.15. Degradation of M-8 In Flexible

Connection

-90-

Page 105: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

100

MoMENT a

kin

FLt:XIBLE FRAME

-lQO

200

100

MoMENT01----------------------::;kin

-100

-200

200

100

MoMENT 0

kin

-100

-200

k-in/k-300

/SEMI-RIGID FRAME

FIXED FRAME

-15 -10 -5 oSHEAR, kips0.359' TAFT

5 10

Figure 6.16 Moment versus Shear of Connection =#= 4

-91-

Page 106: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

e

Point of Inflection

Moment Diagram

M

Shear

+-+e

Figure 6.17 Relation Between the Slope in Moment vs Shear

Plot and the Location of the point of Inflection

in the Moment Diagram

-92-

Page 107: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

15

10

SHEAR

0

ItiPs

-5

-10

-15 '-----

FIXED FRAME

I

,2450 k/rad

I I

SEMI-RIGID FRAME

/

j1050 k/rad

-0.02 0.0

ROTATION, rad0.359 TAFT

0.02

FLEXIBLE FRAME

0.02 0.0

ROTATION, rad0.359 TAFT

0.02

10 )::""--------------------;;---------------------,

5

SHEAR, 0

ItiPs

-5

~ad

-10

-0.06 -0.04 -0.02 0.0

ROTATION, rad0.3Sq TAFT

0.02 0.04 0.06

Figure 6.18 Shear Force versus Rotation of Connection =#= 4

-93-

Page 108: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

6,---------------------------------------,

2

Brace * 1

-2

2

Brace * 2

0Brace

F -20rce 7'

sBrace * 3

kips 0

-2

Brace * 4

-2

-6 lL.----.l...----_l.- l.- -L---_--l ---l --L --l

10 20 30 40

'1!DlE, sec0.359 TAFT

Figure 6.19 Time History of the Axial Force in the Diagonal

Braces of the Flexible Structure

-94-

Page 109: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

:a

o 1--_WAl-III

SEMI-RIGID FRAME

Brace * 1

Brace * 2

B 0

race

F -:a0rc :aes

kips 0

-:a

:aBrace *4

o t---+H~

-:a

o 10 :ao'fID, sea0.359 TAft

30

Figure 6.20 Time History of the Axial Force in the Diagonal

Braces of the Semi-Rigid Structure

-95-

Page 110: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FI :) 'l,U.

Brace * 1

-2

Brace * 2

0

Brace

F -2

0rce5

k Brace * 3iP5

0

-2

Brace * 4

-2

10 20 30 40

TIME, sec0.359 TAFT

Figure 6.21 Time History of the Axial Force in the Diagonal

Braces of the Fixed Structure

-96-

Page 111: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

1.460"

+-+ -+-+~200.7 k-in~ 44.6 k-in...- 5.08 k ... 2.4 k

IIIIIIII

1.288"

-+-+~251.2 k-in

...- 6.45 kIIIIIIII

~ 6.45 k

~54.g k-in

~5.08 k

~.g k-in

• 2.4 k

~00.8 k-in

Fixed Semi-Rigid Flexible

Maximum Deflection of The S-W Column

Figure 6.22 Maximum Deflection of S-W Column For the Three

Structures Under Dynamic Loading

-97-

Page 112: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

400

200

o

-200

-

-

FLEXIBLE FRAME

A~ A{ ~I 1\ !\~ Ii r A IA~ A IAf IA IAAAAAflliv "VVV I IV IVI I~

IV V III I~ IIV ~\ 'VVV vyv

-

Base

200

SEMI-RIGID FRAME

P1ate

Moment

K

in -200

200

FIXED FRAME

-200

V M

-400 tt:.... --.JL- ----l. -L .L.... ---I -L ..l-~_____J

o 10 20

TIME, sec0.359 TAFT

30 40

Figure 6.23 Time History of the Moment in Base Plate =IF 4

-98-

Page 113: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

1/8" SlipDownwards

T

~I••••

,.. f.. I

Y ~Yield inColumnFlanges

••••••••

Yield in

Column

Figure 6.24 Yielding in the Columns of Semi-Rigid Structure

After O.35g EI-Centro

-99-

Page 114: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Angle

ed Shape1/8

~I•••• 3/1611 Slip

DownwardsI T

~

~I

Seated-tt\I Deform

Figure 6.25 Plastic Deformation in Semi-Rigid

Connections after O.5g Taft

-lOG-

Page 115: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

-~ ------- ----------------.rI H --------------------1

LlII

t 3/16" :--- -------------------~i~- ----------- -----,

Figure 6.26 Slippage in Flexible Connection

-101-Reproduced frombest available copy.

Page 116: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

Yielding

,\ r;

... t'

I

••••

,.. I~ ~ T

I~~. .

Figure 6.27 Yielding in the N-W Column of Fixed Structure after

0.35g Taft

-102-

Page 117: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

APPENDIX A

As mentioned earlier, only 8 plots were developed for the 24 selected shaking

table tests. The plots are presented as follows:

I. FLEXIBLE FRAME

FREE VIBRATION

EL CENTRO E.Q.

O.15g intensity

O.25g intensity

o.35g intensity

TAFT E.Q.

O.15g intensity

O.35g intensity.

O.50g intensity

MEXICO E.Q.

O.35g intensity

O.50g intensity

-103-

II. SEMI-RIGID FRAME

FREE VIBRATION

EL CENTRO E.Q.

O.15g intensity

O.25g intensity

o.35g intensity

TAFT E.Q.

O.15g intensity

O.35g intensity

O.50g intensity

MEXICO E.Q.

O.35g intensity

O.50g intensity

Page 118: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

llI. FIXED FRAME

FREE VIBRATION

EL CENTRO E.Q.

O.15g intensity

O.25g intensity

o.35g intensity

TAFT E.Q.

O.15g intensity

O.35g intensity

NOT AVAlLABLE

lviEXICO E.Q.

NOT AVAlLABLE

NOT AVAlLABLE

For each of the test runs the the following plots are presented:

(1) Connection 4: Moment versus Rotation

(2) Connection 4: Shear versus Rotation

(3) Connection 4: Moment versus Shear

(4) Time history of the moment of base plate 4

(5) Time history of the base shear

(6) Time history of the lateral drift

(7) Plot of stiffness

(8) Plot of the fast Fourier amplitude versus frequency

-104-

Page 119: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

2

BASE

SHEAR

kiPs -1

-2

-3

10 11 12 13 14 15 16 17 18 19 20

0.2 r.....,....._-'....

0.1 I-

LATERAL

oRr 0FT

inches

TIME, secFREE VTBHATION

FLEXIBLE FRAME

-0.1 -

-0.2

\

l----,----,_-'-----"~ __J _"_ _ L_ L __L~-' ~ _-"---' _ L-l_ _I _I __ L _J __~-, ~j10 11 12 13 14 15 16 17 18 19 20

TIME, secFRF:P. VIBRATION

-105-

Page 120: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

BASE

SREAR

1<ips -1 _.

-2

-3 ~

FLEXIBLE FRAME

________. .1 --"-0.2 -0.1 0.0

LATERAL DRIFT, inchesFREE VIBRATION

-106-

0.1 0.2

Page 121: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

K

IN

-100

-200

-300

FLEXIBLE FRAME

l-

I-

i-

l-

I-

l- I I I I

l-

i-

~wdI""

i-

l-

I I I I

-0.06

15

10

5

SHEAR

kiPs

-5

-10

-15-0.06

-0.04

-0.04

-0.02

-0.02

0.0

ROTATION, rad0.15g ELCENTRO

FLEXIBLE FRAME

0.0

ROTATION, rad0.15g ELCENTRO

-107-

0.02

0.02

0.04

0.04

0.06

0.06

Page 122: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENor 0

It

in

-100

-200

-300

FLEXIBLE FRAME

l-

I-

'-

....,:::-,--

'-

l- I I I I

-15 -10 -5

SHEAR, kips0.15g ELCENTRO

FLEXIBLE FRAME

10 15

300

200

BASE

pLAorE

M 00MENT

Ie

IN

-200

-300

10 20

TIME, seco . 15 g ELCENTRO

-108-

30 40

Page 123: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SHEAR

-20

-30

10

FLEXIBLE FRAME

20

TIME, sec0.159 ELCENTRO

FLEXIBLE FRAME

30 40

6

LAT 2ERAL

oRIFT

inch -2es

-4

-6

10 20

TIME, sec0.159 ELCENTRO

-109-

30 40

Page 124: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

-20

-30

FLEXIBLE FRAME

,-!I,

f-

-

/I

-

-

f- I --- I I I

0.08

0.06

FoURIER

AMPLITUDE

0.02

0.0

-6 -4 -2

LATERAL DRIFT, inches0.159 ELCENTRO

FLEXIBLE FRAME

10 20 30 40 50

FREQUENCY, hertz0.159 ELCENTRO

-110-

60 70 80 90 100

Page 125: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMEN

T 0

K

IN

-100

-200

-300

FLEXIBLE FRAME

-0.06

15

10

5

5HEAR

kiPs

-5

-10

-15

-0.06

-0.04

-0.04

-0.02

-0.02

0.0

ROTATION, rad0.25g ELCENTRO

FLEXIBLE FRAME

0.0

ROTATION, rad0.259 ELCENTRO

-111-

0.02

0.02

0.04

0.04

0.06

0.06

Page 126: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

HoHENT 0

k

in

-100

-200

-300

-15 -10 -5

FLEXIBLE FRAME

SHEAR, kips0.259 ELCENTRO

FLEXIBLE FRAME

.L- ~__

10 15

300

200

BA5E:

PLATE

M 0oMENT

IN

-200

-300

-

-

I-

A M IA! ~ ~ In n.~JI ~~~ ~ ~ ~ n~ !

V V II VV v \I IV~V~~~· V I~VVVVV

L

II

l- Ii

il- I I I I I I_J

10 20

TIME, sec0.25g ELCENTRO

-112-

30 40

Page 127: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

SHEAR

-20

-30

FLEXIBLE FRAME

=-- --L.- --.L --l l-- -L L

LAT 2ERAL

10 20

TIME, sec0.2Sg ELCENTRO

FLEXIBLE FRAME

30 40

DRIFT

nch -2es

-4

-6_--'--- ,L.- -"-- --'--__._------.L _

10 20

TIME, seca 25g ELCF:NTRO

-113-

30 40

Page 128: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SHEAR

k

-20

-30

FLEXIBLE FRAME

r--------~--.----------.__-------------

0.07

-6 -4 -2

LATERAL DRIFT, inches0.25g ELCENTRO

FLEXIBLE FRAME

0.06 f-

0.05

FoUR

~R

AMPJ.ITUDE

0.02

0.01

0.0

10 20 30 40 50

FREQUENCY, hertz0.25g ELCENTRO

-114-

60

..w.

70 80 90 100

Page 129: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT

K

IN

-100

-200

-300

-0.06

15

10

5

SHEAR

0

kiPs

-5

-10

-15

-0.06

-0.04

-0.04

-0.02

-0.02

FLEXIBLE FRAME

0.0

ROTATION, rad0.35g ELCENTRO

FLEXIBLE FRAME

0.0

ROTATION, rado 35g ELCENTRO

-115-

0.02

0.02

0.04

0.04

0.06

0.06

Page 130: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT

Ie

in

-100

-200

-300

FLEXIBLE FRAME

-15 -10 -5

SHEAR, kipsO.35g ELCENTRO

FLEXIBLE FRAME

10 15

300

200

BASE

PLATE

M 0oMENT

IN

-200

-300

-

-

f-

A~ ~~ ~ IA~ I\~I II I~ ~AA IAA~ IInAA~~

~ ij~ II 1\ IV~ IVI IVV' VV I ~ VI I~~VVVV

-

-

H- I I I I I I --o 10 20

TIME, seco 150 f'T.rFN'T'JU)

-116-

30 40

Page 131: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5HEAR

i

-20

FLEXIBLE FRAME

-30

10 20

TIME, sec0.35g ELCENTRO

__---l --'- _

30 40

LAT 2ERAL

DRIFT

inch -2e5

-4

-6

FLEXIBLE FRAME

---l J10 20

TIME, secO. 35g ELCENTRO

-117-

30 40

Page 132: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30 r-:·-----------------·----

JB 10A5E

5HEAR

k

-20

FLEXIBLE FRAME

r

- 30 L-=- '-- -.1 ~_ _ L- L- -'

-6 -·4

LATERAL DRIFT I incheso 35g f;LCENTRO

FLEXIBLE FRAME

0.07

0.06 - I

0.05 -

F0URIER

AMPLITUDE

0.02

0.01

0.0

10 20 30 40 50

FREQUENCY, hertzO.35g ELCENTRO

-118-

60 70 80 90 100

Page 133: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

300

200

100

MoMENT

IN

-100

-200

-300

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.159 TAFT

FLEXIBLE FRAME

0.060.040.020.0-0.02-0.04

t-

r-

~.Jj

,;J.?

r-

r-

I I I I-15

-0.06

-10

-5

I<ips

5HEAR, 0

10

15

ROTATION, rad0.159 TAFT

-119-

Page 134: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

Ie

in

-100

-200

-300

FLEXIBLE FRAME

l-

f-

f-

-

-

- I I I I

-15 -10 -5

SI1EAR, kips0.15g TAFT

FLEXIBLE FRAME

10 15

300

200

BASE

PLATE

M 00MENT

IC

IN

-200

-300

o 10 20

TIME, sec0.15g TAFT

-120-

30 40

Page 135: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10

A5E

5H

~ 0R

-20

-30

LATERAL

10

FLEXIBLE FRAME

20

TIME, sec0.15g TAFT

FLEXIBLE FRAME

30 40

oRIFT

inch -2es

-4

-6 __..L._ .... _. IlL- ---.L ..J- --' -L L-__~__'__

10 20

TIME, sec0.15g TAFT

-121-

30 40

Page 136: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

30

20

B 10A5E

5H

~ 0R

-20

-30

-

-

-

l-

I-

l- I I i I

-6 -4 -2 o

LATERAL DRIFT, inches0.15g TAFT

FLEXIBLE FRAME

2

0.07 ,------------------------------------------------,

0.06 I-

0.05

FoUR

~R

AMP~ITUDE

0.02

0.01

0.0

o 10 20 30 40 50

FREQUENCY, hertz0.15g TAFT

-122-

60 70 80 90 100

Page 137: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

I<:IN

-100

-200

-300

FLEXIBLE FRAME

-0.06

15

10

SHEAR

kiPs

-5

-10

-15

-0.06

-0.04

-0.04

-0.02

-0.02

0.0

ROTATION, rad0.359 TAFT

FLEXIBLE FRAME

0.0

ROTATION, rad0.359 TAFT

-123-

0.02

0.02

0.04

0.04

0.06

0.06

Page 138: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

300

200

100

MoMENT 0

kin

-100

-200

-300

-15

300 I-

200 I-

-10 -5 o

SHEAR, kips0.359 TAFT

FLEXIBLE FRAME

10 15

BASl': ~

PLATE

..~~M 00MENT

IC

IN

-200 ~

\II

-300 ll-'l- ---'- L- L- ~ L I . --l..-__. _

10 20

TU!E, secO.35g TAFT

-124-

30 40

Page 139: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

kiP5-10

-20

-30

FLEXIBLE FRAME

o 10 20

TIME, sec0.35'1 TAFT

FLEXIBLE FRAME

30 40

6

4

LATERA 2L

oI5pLACEMENT

i -2nche5

-4

-6

10 20

TIME, sec0.35'1 TAFT

-125-

30 40

Page 140: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

-30

FLEXIBLE FRAME

-6

0.07

0.06 -

0.05

FoUR

iR

AMPJ.ITUDE

0.02

0.01

-4 -2 o

LATERAL DRIFT, inches0.359 TAFT

FLEXIBLE FRAME

2

0.0

10 20 30 40 50

FREQUENCY, hertz0.359 TAFT

-126-

60 70 80 90 100

Page 141: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

IN

-100

-200

FLEXIBLE FRAME

-0.06

15

10

5

SHEAR

0

);

iPs

-5

-10

-15

-0.06

-0.04

-0.04

-0.02

-0.02

0.0

ROTATION, rad0.5g ThFT

FLEXIBLE FRAME

0.0

ROTATION, rad0.5g TAFT

-127-

0.02

0.02

0.04

0.04

0.06

0.06

Page 142: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

k

in

-100

-200

-300

FLEXIBLE FRAME

___-'--__~~_~__.L_ _"_ ~

-15 -10 -5 o

SHEAR, kips0.59 TAFT

FLEXIBLE FRAME

10 15

300

200

BASE

PLATE

M 0oMENT

K

IN

-200

-300

-

-

-

.~A~ \~I .~ I~~ A ~~ 1~~~~AAAvvv ,I'. ~ rV~1 IV !~ VVV v

-

-

-t- I I I -l I

10 20

'tIME, seco 5g TAFT

-128-

30 40

Page 143: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

30

20

B 10ASE

SH

~ °1---AJ'tf~iIit~tt1iTmffi~rttHiffift71itHi1t\th~Tttfttti11tt1f1f1rJWfftJlH1-1i1\fnPrl+m~LtJjrttJ~mtAA/1Jtf'tAJA:-------I

kiP5-10

-20

-30

10 20

TIME, secO,5g TAFT

FLEXIBLE FRAME

30 40

LAT 2ERAL

DRI 0FT

inch -2e5

-4

-6 lL- -L -'--- L- ---.J -.-L ..L._ _J-.. _

o 10 20

TIME, seco 5g TAFT

-129-

30 40

Page 144: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SHEAR

kiP5- 10

-6

0.10 [

0.08

FoURIER

AMPL

fuDE

0.02

-4

FLEXIBLE FRAME

-2

LATERAL DRIFT, incheso 59 TAFT

FLEXIBLE FRAME

0.0

o 10 20 30 40 50

FREQUENCY/hertzo 59 TAFT

-130-

60 70 80 90 100

Page 145: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

300

200

100

MoMENT 0

K

IN

-100

-200

-300

-

-

>-

~ .- ...........

--.-..;: ~

>-

l-

I I I I

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.35", MEXICO

FLEXIBLE FRAME

0.060.040.020.0-0.02-0.04

-15

-0.06

-10

15 .----------------------__--, --,

-5

kiP5

5HEAR, 0

5

10

ROTATION, rad0.35q MEXICO

-131-

Page 146: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT

k

in

-100

-200

-300

FLEXIBLE FRAME

-15 -10 -5

SHEAR, kipsO. 359 MEXICO

FLEXIBLE FRAME

5 10 15

300

200

BASE

PLATE

M 0oMENT

IN

-200

-300

c-

f-

- ~

A AA ! A

f\

A A A /\ AAAf\I\f\/'\f\

v V VJV V VVVVV ~

Vv V V

c-

c-

H- I I I I I ----L.~_l- I .l----.l I I

TIME, SecO.35g MEXICO

-132-

10 11 12 13

Page 147: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

-30

6

2

FLEXIBLE FRAME

6

TIME, sec0.35g MEXICO

FLEXIBLE FRAME

9 10 11 12 13

LAT 2ERAL

DRI 0FT

inch -2es

-4

-6 L ~_--l__---.1__---'-__-L__--'--__-L__.....L_'--.....L__-L....__-L1_--.-1

2

TIME, secO. 35g MEXICO

-133-

10 11 12 13

Page 148: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

kiP5-10

-30

-6

0.12

0.10 '-

F -0URIER

1;. -MPLITU0E t-

0.02 t-

~0.0 1/ ~. "row

-4 -2

FLEXIBLE FRAME

LATERAL DRIFT, inches0.359 MEXICO

FLEXIBLE FRAME

J

2

o 10 20 30 40 soFREQUENCY, hertz

0.359 MEXICO

-134-

60 70 80 90 100

Page 149: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT

ItIN

-100

-200

-300

FLEXIBLE FRAME

r

l-

I-

L~-.

~ .......~..

~ ~

r

l-

I- I I I I

-0.06

15

10

5

SHEAR, 0

kiP5

-5

-10

-15

-0.06

-0.04

-0.04

-0.02

-0.02

0.0

ROTATION, rad0.59 MEXICO

FLEXIBLE FRAME

0.0

ROTATION, rad0.59 MEXICO

-135-

0.02

0.02

0.04

0.04

0.06

0.06

Page 150: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

kin

-100

-200

-300

FLEXIBLE FRAME

-15

300

-10 -5 oSHEAR, kips0.5g MEXICO

FLEXIBLE FRAME

10 15

200

BASE.

pLATE

M 00MENT

Ie

IN

-200

-300

TIME, sec0.50g MEXICO

-136-

10 11 12 13

Page 151: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

ItiP5-10

-20

-30

FLEXIBLE FRAME

TIME, secO.Sg MEXICO

FLEXIBLE FRAME

6

LATER

~ 2

DISp

LACEMENT

i -2nche5

-4

-6

6

TIME, sec0.5g MEXICO

-137-

IO II I2 I3

Page 152: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FLEXIBLE FRAME

30

20

B 10A5E

5H

~ 0R

kiP9-10

~" I~

-30 LL_' ----'- --'- .L- -.l ---'- ---'

-6

0.14

0.12

0.10

FoUR

~.R

AMPJ.ITUDE

0.04

-4 -2

LATERAL DRIFT, inches0.5g MEXICO

FLEXIBLE FRAME

2

0.02

0.0 t10 20 30 40 50

FREQUENCY, hertz0.50g MEXICO

60 70 80 90 100

Page 153: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

B 1ASE

SIlEA1\

I<ips -1

-2

-3

SEMI-RIGID FRAME

r-

I-

~

I-

A~AAAAAAAAAAAAAAAAAAIVVVVVVVVVVVVVVVVVV

r-

I-

- I I I I I I I I I I I ----l I I I I I I I _----"

2 7 10 11 12 13 14 15 16 17 18 19 20

TIME, secFREE VIBRATION

SEMI-RIGID FRAME

0.2

0.1

LAorERAL

o1\IFor

inches

-0.1

-0.2

r-

I-

!.fi fi WA nw !!AAA0n0Ann ~ , n, , " , , , , , , ,r lJ \[~ ~ ~ VVVVlJ VVIJ1J\fV VV1[1[01) VV \[VlJ VV VV01 QIJ

r-

It- I I I I I I I -l I I I I--.L I I I I I I

1 8 9 10 11 12 13 14 15 16 17 18 19 20

TIME, secFREE VIBRATION

-139-

Page 154: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

2

B 1A5E

5HEAR

ItiPs -1

-2

-3

SEMI-RIGID FRAME

-0.2 -0.1 0.0

LATERAL DRIFT, inchesFREE VIBRATION

-140-

0.1 0.2

Page 155: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT 0

IN

-100

-200

-300

-

-

-

f-

-

l- I I I I

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.15g ELCENTRO

SEMI-RIGID FRAME

0.060.040.020.0-0.02-0.04

l-

I-

il

,

l-

I-

I I I I

-10

-5

kips

SHEAR, 0

5

10

-15

-0.06

15

ROTATION, rad0.15g ELCENTRO

-141-

Page 156: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

1<

in

-100

-200

-300

SEMI-RIGID FRAME

-

-

-

//

r-

I-

- I I ·1 I

-15 -10 -5

SHEAR, kips0.159 ELCENTRO

SEMI-RIGID FRAME

5 10 15

300

200

BASE

PLATE

M 00MENT

It

IN

-200

-300

10 20

TIME, sec0.159 ELCENTRO

-142-

30 40

Page 157: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5HEAR

-20

-30

4 -

LAT 2 l-ERAL

DRI 0FT

inch -2 -es

10

SEMI-RIGID FRAME

20

TIME, sec0.159 ELCENTRO

SEMI-RIGID FRAME

30. 40

-6 I I I I J ,0 10 20 30 40

TIME, sec0.159 ELCENTRO

-143-

Page 158: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

-30

SEMI-RIGID FRAME

f-

-

f-

I

/-

f-

l- I I I I

-6

0.05

0.04 -

F0Uk l-IER

AMPLJ. l-TUDE

0.01

0.0

-4 -2 oLATERAL DRIFT, inches

0.15,! ELCENTRO

SEMI-RIGID FRAME

2

10 20 30 40 50

FREQUENCY, hertzO. 15,! EI>CENTRO

-144-

60 70 ao 90 100

Page 159: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT

IN

-100

-200

-300

f-

f-

~ J

f-

J

~

l- I I I -----1________ ..__-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.25g ELCENTRO

SEMI-RIGID FRAME

15

10 ~

5 f-

SHEAR, 0

IkiPs

-5 ~

-10 I-

0.060.040.020.0-0.02-0.04

-15 ~----.L-_-----J-. ._.---J,-- ...l. . L _-0.06

ROTATION, rado 259 ELCENTRO

-145-

Page 160: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

200

100

MoMENT 0

k

in

-100

-200 -.

------------r-----------------------,

-300

-15

300

-10 -5

._._... .1._.. ...~__.. _..1 _

10

SIlF:AR, kips0.259 ELCENTRO

. SEMI-RIGID FRAME

15

200

BASF

PLATE

M 00MENT

I(

IN

-200

-300 lI...'- -'-- -L ...L

10 20

TIME, sec0.25g ELCENTRO

-146-

30 40

Page 161: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI -RIGID FRAME

30r----------------------------- .---.-------------. __ .-

20

B 10

A5E

5HEAR

-20

3b20

_.1 ._. ...1..- ~ ..l.... .._l _

4010

-30 ft._

TIME, secO.2'Jg ELCENTRO

SEMI-RIGID FRAME

LAT 2ERAL

DRI 0FT

inch -2es

-4

-6

10 20 30 40

TTr1E, seco ~5g £LCFNTRO

-147-

Page 162: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

SEMI-RIGID FRAME

-30

-6

0.10

0.08

FoUIIIER

-4 -2

LATERAL DRIfT, inches0.25g ELCENTRO

SEMI-RIGID FRAME

AMPL

4uDE

0.02

~0.0

10 20 30 40 50

FR!·~0!;ENCY,hellzo ') "<J F.LCENTRO

-148-

60 70 BO 90 100

Page 163: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT

K

IN

-100

-200

-300 '--'- -'- -l._~ . ~ _ ._-.l ~I-0.06

15

-0.04 -0.02 0.0

ROTATION, rad0.35g ELCENTRO

SEMI-RIGID FRAME

0.02 0.04 0.06

10 f-

5 r--

~sHE fA

IR0

(f!k

ps

-5 r--

-10 f-

_L-- -.1 ._-15 'l.....--

-0.06 -0.04 -0 02 0.0

ROTl\T rON, r<1df) 35<J ELCf:NTRO

-149-

0.02 0.04 o 06

Page 164: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300---,-----~~--------------------,

200

100

MoMEN

T 0

k

in

-100

-200 -

1510

___, ..~ __i I__~ _

-5-10

-300 l:=- . -L ~.L. . _

-15

SHEAR, kips0.3'9 ELCENTRO

SEMI-RIGID FRAME

300 -

200

BASE

p

LATE

M 00MENT

K

IN

-200

30

-300

10

1 --1- ---'- _

20

---L ~_.

40

TIME, sec0_35g ELCENTRO

-150-

Page 165: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

30 rf----------------------·--------------------.- ---,

20 I-

B 10 I-

ASE

S

~ 1M ~ ~ ~H

~ ~AAE "A VI '~VVRI' \ Ii

kiP5-10 I-

-20 -

-30 lI::--------'-- -'-- -'- -'-- --l L-- -'- ~

10 20

TIME, sec0.35g ELCENTRO

SEMI-RIGID FRAME

30' 40

6 ~------------------------------------.-------__,

LAT 2ERAL

DRI 0FT

inch -2e5

-4

-6

10 20

TIME, sec0.35g ELCENTRO

-151-

30 40

Page 166: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

]0

20

B 10ASE

SH

~ 0R

-20

-]0

-6

0.10

0.08 f-

F0UlR -IER

AMPL

~ -UDE

0.02 -

0.0

-4 -2

SEMI-RIGID FRAME

LATERAL DRIFT, inches0.359 ELCENTRO

SEMI-RIGID FRAME

.1. l .J. J

o 10 20 30 40 50

FREQUENCY, hertzO. 35<] ELCENTRO

-152-

60 70 80 90 100

Page 167: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

0.060.040.0-0.02-0.04

=-

-

I-

~l- If-

l- I I I I I

300

100

200

IN

MoMENT 0

-300

-0.06

-200

-100

ROTATION, rad0.15g TAFT

SEMI-RIGID FRAME

0.060.040.020.0-0.02-0.04

l-

f-

V)

-

l-

I I I I-15

-0.06

-10

-5

kiPs

SHEAR, 0

10

15

ROTATION, radO.15g TAFT

-153-

Page 168: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT

k

in

-100

-200

-300

SEMI-RIGID FRAME

-15 -10 -5

SHEAR, kips0.15g TAFT

SEMI-RIGID FRAME

5 10 15

300

200

BASE

PLATE

MoMENT

Ie

IN

-200

-300

10 20

TIME, sec0.15g TAFT

-154-

30 40

Page 169: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

-20

-30

10

SEMI-RIGID FRAME

20

TIME, sec0.15g TAFT

SEMI-RIGID FRAME

40

6

LAT 2ERAL

DRI 0FT

iDC

h -2es

-4

-6o 10 20

TIME, sec0.15g TAFT

-155-

30 40

Page 170: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

kiP8-10

-20

-30

SEMI-RIGID FRAME

t-

-

-

Vl-

II-

- I I I I

-6

0.10

0.08 -

F0UJl. -IER

AMPL

~ -UDE

0.02

0.0

-4 -2 o

LATERAL DRIFT, inches0.15'1 TAFT

SEMI-RIGID FRAME

.11.

2

10 20 30 40 50

FREQUENCY, hertz0.15'1 TAFT

-156-

60 70 80 90 100

Page 171: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT 0

KIN

-100

-200

r-------------~-------

-300

-0.06 -0.04 -0.02 0.0

ROTATION, rad0.359 TAFT

0.02 0.04 0.06

SEMI-RIGID FRAME

15

10

5HEAR, 0

kiPs

-5

-10

-15

-0.06 -0.04 -0.02 0.0

ROTATION, rad0.359 TAFT

-157-

0.02 0.04 0.06

Page 172: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

kin

-100

-200

-300

SEMI-RIGID FRAME

-15 -10 -5

SHEAR, kips0.359 TAFT

SEMI-RIGID FRAME

10 15

300

200

BASE

PLATE

MoMENT

IC

IN

-200

-300

o 10 20

TIME, sec0.359 TAFT

-158-

30 40

Page 173: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

-30

SEMI-RIGID FRAME

i-

i-

I-

,dJ~ i I~~~~A !~ ~~ ~- V vv vV~ I IV ~V VII

IV 'v V 'v

-

'-

it- I I I I I

o 10 20

TIME, sec0,35g TAFT

SEMI-RIGID FRAME

30 40

6

LATERA 2L

DISPLACEMENT

i -2nches

-4

-6

10 20

TIME, sec0_ 35g TAFT

-159-

30 40

Page 174: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

-20

-30

0.20

0.15 I-

FoURIER

;. ­MPLITUoE

0.05 -

0.0

-4 -2

SEMI-RIGID FRAME

LATERAL DRIFT, inches0.35'1 TAFT

SEMI-RIGID FRAME

.,.1

2

10 20 30 40 50

FREQUENCY, hertzO.35g TAFT

-160-

60 70 80 90 100

Page 175: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT

K

IN

-100

-200

L.-- -L ~ .__. __'____-300

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, radO.Sg TAFT

SEMI-RIGID FRAME

15

10

SHEAR

kiPs

-5

-10

L -'--- J -'-15

-0,06 -0.04 -0 02 0.0 0.02 0,04 0.06

ROTATION, rado 5g TAFT

-161-

Page 176: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT 0

k

in

-100

-200 -.

.l~. .L ~__~__I- 300 tc

-15 -10 -5

_______~ J _

10

SHEAR, kips0.5g TAFT

SEMI-RIGID FRAME

15

300 FI

200

BA5E

PLATE

M 00MENT

It

IN

-200

300 lLff-----l.......--------L. ----.l .l...- -...l... L-. ..J.... .---J

10 20

'rIME, sec0_ 5g TAFT

-162-

30 40

Page 177: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SHEAR

-20

-30

SEMI-RIGID FRAME

~

l-

I-

~.~ ~ ~ ~ ~I I ~

A 111 ~~AAf\Ao~,IIIVV' •~ IP IIi VI I VIJV

l-

I-

l I I ----L____L- I I10 20

TIME, seco 5g TAFT

SEMI-RIGID FRAME

30 40

LAT 2ERAL

DRI 0FT

inch -2es

-4

-6

10 20

TIME, seco .5g TAFT

-163-

30 40

Page 178: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

kiP8-10

-20

-30

SEMI-RIGID FRAME

0.16

-6 -4 -2

LATERAL DRIFT, inches0.5g TAFT

SEMI-RIGID FRAME

0.14

0.12

F

gRIER

AMPLIrUoE

.04

.02

0.0

10 20 30 40 50

FREQUF.:NCY, hertzO.Sg TAFT

60 70 80 90 100

Page 179: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

ItIN

-100

-200

-300

SEMI-RIGID FRAME

-0.06

15

10

-0.04 -0.02 0.0

ROTATION, radO. 35g MEXICO

SEMI-RIGID FRAME

0.02 0.04 0.06

5

SHEAR

k

pS

-5

-10

-0.06 -0.04 -0.02 0.0

ROTATION, radO. 35g MEXICO

-165-

0.02 0.04 0.06

Page 180: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

kiP5-10

-20

-30

SEMI-RIGID FRAME

-6

0.20

0.15 f--

FoURIER

A f-­MPLITUDE

0.05 f--

-4 -2

LATERAL DRIFT, inches0.359 MEXICO

SEMI-RIGID FRAME

0.0

FREQUENCY, hertzo . 359 MEXICO

-166-

Page 181: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10

ASE

SHEAR

-20

-30

SEMI-RIGID FRAME

8

TIME, sec0.35g MEXICO

SEMI-RIGID FRAME

10 11 12 13

6

LATERAL

DRIFT

nch -2e5

-4

-6

1 2

TIME, s~c

0.35g MEXICO

-167-

9 10 11 12 13

Page 182: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

100

MoMENT 0

kin

-100

-200

-300

-15 -10 -5 o 10 15

SHEAR, kips0.359 MEXICO

SEMI-RIGID FRAME

300

200

BASE:

PLATE

M 00MENT

K

IN

-200

13o-300 "------'------!.------'-----...L.. '--__-'- -'- -'-__--.J'--__-'-- ...L.. '--__-"

TIME, sec0.359 MEXICO

-168-

Page 183: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

300

200

--l100

MoMENT 0

KIN

-100

-200

- 300 '--- J-- ---l _ _______-----L_ J-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.5g Ml';XICO

SEMI-RIGID FRAME

15

10

5

SHEAR, 0

kips

-5

-10

'--- .L..... -.--L_~ _-15

-0.06 -0.04 -0.02 0.0

ROTATION, rad0.5g MEXICO

-169-

0.02 0.04 0.06

Page 184: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

SEMI-RIGID FRAME

---,.------_.. _------~-----------,

100

MoMENT 0

kin

-100

_______... ._ .1. _~-----~---

-15

300

200

BASE:

-10 -5

SHEAR, kipso ~)g MEXICO

SEMI-RIGID FRAME

10 15

PLATE

MoMENT

K

IN

-200

-300

2 4. 10

TIME, sec0_ 50g MEXICO

-170-

11 12 13

Page 185: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

kiPS-10

-20

-30

SEMI-RIGID FRAME

l-

I-

l-

n fI

An A

JA

A~ Af\ f\ f\A!\ ArJ\~V\

V \ v V ~ VVVVv~~

Vl-

I-

H- I I I I I I I I I I I I

5

TIME, secO.Sg MEXICO

SEMI-RIGID FRAME

11J 11 12 13

LATERAL

DI5pLACEMENT

i -2nches

-4

-6

TIME, sec0.5g MEXICO

-171-

10 11 12 13

Page 186: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

SEMI-RIGID FRAME

30

20

B 10A5E

5H

~0f----------------------;4R

-20

-30 =- -'-- --L ~__L_ __'_ ~ _

-6 -2

LATERAL DRIFT, incheso ~ 5g MEXICO

SEMI-RIGID FRAME

0.25

0.20

FoUR.IER

AMPL

~UDE

0.05

0.0

10 20 30 40 50

FREQUENCY, hertzo 50g MEXICO

-172-

60 70 80 90 100

Page 187: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

2

B1

ASE

SHE 0AR

kips -1

-2

-3

FIXED FRAME

r-

r-

.......

r-

AAAAAAAAAAAAVVI~~VVVVVVVVV~

r-

r-

l+- I I I I I I I I I I I I I I I I I I .--L.-Jo 10 11 12 13 15 16 17 18 19 20

0.2

0.1

LATERAL

DRIFT

inches

-0.1

-0.2

TIME, secFREE VIBRATION

FIXED FRAME

10 11 12 13 14 15 16 17 18 19 20

TIME, secFREE VIBRATION

-173-

Page 188: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

B1

ASE

SHE 0AR

kiPs -1

-2

-3

FIXED FRAME

.-'--------_._----'-----------_-'!

-0.2 -0. 0.0

LATERAL DRIFT, inchesFREE VIBRATION

-174-

0.1 0.2

Page 189: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

300

200

100

MoMENT

IN

-100

-200

-300

i-

i-

l-

I-

-

i- I I I I

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.15g ELCENTRO

FIXED FRAME

0.060.040.020.0-0.02-0.04

-

l-

I!

l-

i-

I I I I

-10

-5

Ii:iPs

SHEAR

5

10

-15

-0.06

15

ROTATION, rad0.15g ELCENTRO

-175-

Page 190: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT 0

k

in

-100

-200

-300

FIXED FRAME

-

f--

f--

//

f--

l-

f-- I I I I

-15 -10 -5 o

SHEAR, kips0.159" ELCENTRO

FIXED FRAME

5 10 15

300

200

BASE

pLATE

M 00MENT

tc

IN

-200

-300

o 10 20

TIME, sec0.15g ELCENTRO

-176-

30 40

Page 191: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

kiPS-10

-20

-30

FIXED FRp.ME

o

6

4 I-

LAT 2 -ERAL

DRI 0FT

inch -2 -es

-4 -

10 20

TIME, secO.IS,! ELCENTRO

FIXED FRAME

30 40

-6 I I I I I

10 20 30 40

TIME, secO.ISg ELCENTRO

-177-

Page 192: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0R

kiP5-10

-20

-30

FIXED FRAME

f.....

I-

~

V/

f.....

l-

f..... I 1 'I I

-6

0.05

0.04 f.....

F0Ull. ~l:ER

AMPL

; f.....

U0E

0.01 -

-4 -2 o

LATERAL DRl:FT, inches0.15'1 ELCENTRO

FIXED FRAME

2

0.0 ~'l10 20 30 40 50

FREQUENCY, hertz0.15'3 ELCENTRO

-178-

160 70 80 90 100

Page 193: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

0.060.040.020.0-0.02-0.04

I-

-

-

l-

f-

r-' I J_ I I

100

200

300

K

1N

MoMENT

-300

-0.06

-200

-100

ROTATION, rad0.259 ELCENTRO

FIXED FRAME

-

-

/-

-

I I I I

15

10

5

SHEAR

kiP5

-s

-10

-15

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.25q ELCENTRO

-179-

Page 194: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

300

200

100

MoMENT

k

in

-100

-200

-300

-15

300

200

-10 -5 oSHEAR, kips

0.259 ELCENTRO

FIXED FRAME

10 15

BA5E

PLATE

MoMENT

IN

-200

-300 lL- -'-- -'-- l-__~ ~

10 20

TIME, seco 259 ELCENTRO

-180-

30 40

Page 195: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

30

20

B 10A5E

5HEAR

-20

-30 ~.__--"- --"- --"- L

LAT 2ERAL

DRI 0FT

inch -2es

10 20

TIME, sec0.25g ELCENTRO

FIXED FRAME

30 40

-4

-6 '"-----------''---------"---------L .J. L- ,_l- .....J

10 20

TIME, seco 25g ELCENTRO

-181-

30 40

Page 196: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

1<iP"-10

-20

-30 c·_- ---L.. _

-4

0.16

0.14 I-

0.12 I-

F

~ I-RIER

A ­ן

MpLITtJ I­oE

0.04 -

0.02 i-

__-.1 _

FIXED FRAME

----------l.--.- --'-- J

LATERAL DRIFT, inches0.25g ELCENTRO

FIXED FRAME

0.0 I

10 20 30 40 50

FREQUENCY, hertzO. 25g ELCENTRO

-182-

60 70 80 90 10C

Page 197: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

300

200

100

MoMENT

K

IN

-100

-200

-300

l-

I-

f-

l-

I-

l-·· I I I I

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.35g ELCENTRO

FIXED FRAME

0.060.040.020.0-0.02-0.04

f-

l- I

l-

I-

I I I I-15

-0.06

-10

-5

kips

5HEAR, 0

10

15

ROTATION, rad0.35g ELCENTRO

-183-

Page 198: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

300 c---------------------------,--------------------------,

200

100

HoHENT 0

k

in

-100

-200

-300

-15

300

200

BASE

pLATE

H 00HENT

II"

IN

-200

-300 l

-10

10

-5

SHEAR, kips0.35q ELCENTRO

FIXED FRAME

20

TIME, secO.35g ELCENTRO

-184-

30

10 15

40

Page 199: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10IISE

SH

: 0R

-20

-30

o 10

FIXED FRAME

20

TIME, sec0.35g ELCENTRO

FIXED FRAME

30 40

6

LAT 2ERAL

DRI 0FT

inch -2e5

-4

-6

10 20

TIME, sec0.35g ELCENTRO

-185-

30 40

Page 200: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5H

~ 0

R

-20

-30

-6

0.20

0.15 I-

FoURIER

A I­MpLITUDE

0.05 I-

-4 -2

FIXED FRAME

oLATERAL DRIFT, inches

O. 359 ELCENTRO

FIXED FRAME

0.0

10 20 30 40 50

FREQUENCY, hertz0.359 ELCENTRO

-186-

I

60 70 80 90 100

Page 201: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

0.060.040.020.0-0.02-0.04

e- -

'-

l-

I-

l-

I- I I I I

100

200

300

IN

MoMENT

-300

-0.06

-200

-100

ROTATION, rad0.15g TAFT

FIXED FRAME

0.060.040.020.0-0.02-0.04

-

1'-

-

l-

I --.-l I I-15

-0.06

-10

-5

kips

SHEAR, 0

10

15

ROTATION, rad0.15g TAFT

-187-

Page 202: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

300

200

100

MoMENT

k

in

-100

-200

-300

FIXED FRAME

-15 -10 -5 oSHEAR, kips0.159 TAFT

FIXED FRAME

5 10 15

300

200

BASI!:

pLATE

M 00MENT

IC

IN

-200

-300

10 20

TIME, sec0.15g TAFT

-188-

30 40

Page 203: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10ASE

SH

~ 0R

-20

-30

o 10

FIXED FRAME

20

TIME, sec0.15g TAFT

FIXED FRAME

30 40

6

LAT 2ERAL

0RI 0FT

inch -2es

-4

-6

10 20

TIME, seco 15g TAFT

-189-

30 40

Page 204: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

30

20

B 10A5E

5HEAIt

-20

-30

FIXED FRAME

f-

f--

f--

.--

f-

f-- I I I I

-6

0.14

0.12 I-

0.10 t-

F0UIt

~ f-It

AMP

" f-ITUDE

0.04 f-

0.02 t-

0.0

-4 -2 o

LATERAL DRIFT, inches0.15g TAFT

FIXED FRAME

I

6

o 10 20 30 40 50

FREOUENCY, hertz0.159 TAFT'

- 190-

60 70 80 90 100

Page 205: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

300

200

100

MoMENT a

J(

IN

-100

-200

-300

- lc-

I--

t-

;-

~ I I I I

-0.06 -0.04 -0.02 0.0 0.02 0.04 0.06

ROTATION, rad0.359 TAFT

FIXED FRAME

0.060.040.020.0-0.02-0.04

t-

I--

I--

~

I I I I-15

-0.06

-10

-5

Itip$

SHEAR, 0

10

15

ROTATION, rad0.359 TAFT

-191-

Page 206: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

300 c-----------------------;-----------------------

200

100

MoMENT 01---------------------7'''"

kin

-100

-200

-300 C ..L . --L .J- --l. -.l _

-15

300 I-

-10 -5

SHEAR. kips0.35g TAFT

FIXED FRAME

10 15

200 -

BASE I-

PLA

.dhAq~T

•E

M 0

~0 ~V~~V~VlMENT

IC l-

IN

-200 I-

-300~0:=--. ..1-' ..1-1 .-L- ....l1 ---l' ---lI l ----:

10 20

TIME, sec0.35g TAFT

-192-

30 40

Page 207: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

30

20

B 10A5E

5HEAR

-20

-30

I-

~

~

,dAdjW ~ AA ~AAAiY~VV ~VV IVVV

I-

~

l+- I I I I I I I

10 20

TIME, sec0.359 TAFT

FIXED FRAME

30 40

6

LATERA 2L

DI5p

LA 0CEMENT

i -2nche5

-4

-6 IL-~~-~---L~~~~_-L-~~~~---L~~~~~-L-~~__~~~~~~~..L_~_~~--'-~~~~---,

10 20

TIME, secO.35g TAF"r

-193-

30 40

Page 208: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

FIXED FRAME

30

20

B 10l\SE

SH

~ 0R

-20

-30 '----------'- -'-1. .1--.. --'-- -L- ----'

0.20

-6 -4 o

LATERAL DRIFT, inches0.359 TAFT

FIXED FRAME

2 6

0.15 r-

FoURIER

A e­MpLITUoE

0.05 -

0.0

o 10 20 30 40 50

FREQUENCY, hertz0.359 TAFT

-194-

60 70 80 90 100

Page 209: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

APPENDIXB

-195-

Page 210: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

COUPON TESTS

The stress-strain relation of different parts of the structure were developed,

using standard ASTM coupon specimens. The basic interest was to find the

stress-strain curve of the connection angles, since most of the yielding was in that

area. The behavior of the columns, in the areas near the connection, was also ine­

lastic. This inelastic behavior, made it necessary to find the stress-strain curve of

the column so as to understand the behavior of the structure.

Since it had been anticipated that the yield point for material In different

parts of the rolled sections would be different due to variation in rolling of web

and flanges, it was decided that the mechanical properties should be identified for

each pert of the sections.

As indicated in Figure B.l, a total of six coupon specimens, three for W4x13,

two for L2x3-1/2x3/16, and one for L2x2x3/16 were prepared for the uniaxial

monotonic axial tests. The tests were run by a 120 kip Baldwin machine, the out­

put of which was fed to the vertical input of an XY recorder. The strains were

monitored by extentiometers consisting of two LVDT's with a gage length of 1

inches, whose output served as horizantal input of the XY plot. The load rate

used was 20,000 =IF/min.

Typical Stress-strain curves are shown in Figure B.2. Table B.l summarizes

the findings.

-196-

Page 211: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

L 2 x 3 1/2 X 3/16 11

"-1

2

COUPON\

3

L 2 x 2 X 3/16 11

~

1

W 4 x 13

12" 4" I 9"

Figure B.l. Coupon Specimens

-197-

Page 212: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

100

90

80

70

"... 60iii:.::'J

gJ 50wtt:(J) 40

.30

20

10

00

STRESS-STRAIN CURVESW4x13 COUPON 1

STRAIN (STRAINS)

STRESS-STRAIN CURVEL2x3-1!2x3!16 COUPON 1

100

90

80

70

e- 60(J):.::'J

(J) 50(J)Wtt:

Iii 40

30

20

10

0

0 0.04 0.08 0.12 0.16 0.2 0.24 0.28

STRAIN (STRAINS)

Figure B.2. Stress-Strain Relationship

-198-

Page 213: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

TABLE B.lo Coupon Test Results

STRESS-STRAIN RELATIONSHIP

Variable Column W4x13 L2x3-1/2x3/16 L2x2x3/16

Specimen # 1 2 3 1 2 1

Avg. Thickness (in) 0.312 0.329 0.338 0.190 0.191 0.188

Avg. Area (in2 ) 0.232 0.244 0.250 0.141 0.141 0.069

Mod. of Elasticity29.03 30.49 29.57

(103 ksi)29.20 28.70 29.04

Fy upper (ksi ) 56.55 50.08 48.00 61.90 52.70 52.03

Fy lower (ksi ) 53.86 47.20 47.00 59.~0 49.80 52.03

Cy (strain) 0.022 0.016 0.018 0.018 0.018 0.017

Estr.hard (ksi ) 48.00 45.00 41.00 37.00 44.00 50.00

F ult. (ksi) 73.52 70.00 68.40 74.02 69.40 NA

Cult (strain) 0.196 0.210 0.225 0.200 0.210 NA

NA = test was stopped before reaching ultimate strength due experimental problems

-199-

Page 214: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price
Page 215: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

EARTHQUAKE ENGINEERING RESEARCH CENTER REPORT SERIES

EERC reports are available from the National Information Service for Earthquake Engineering(NISEE) and from the National Technical InformationService(NTIS). Numbers in parentheses are Accession Numbers assigned by the National Technical Information Service; these are followed by a price code.Contact NTIS, 5285 Port Royal Road, Springfield Virginia, 22161 for more information. Reports without Accession Numbers were not available from NTISat the time of printing. For a current complete list of EERC reports (from EERC 67·1) and availablity information, please contact University of California,EERC, NISEE, 1301 South 46th Street, Richmond, California 94804.

UCB/EERC·80/01

UCB/EERC-80107

UCB/EERC-80/04

UCB/EERC-80/05

UCB/EERC-80106

'Earthquake Response of Concrete Gravity Dams Including Hydrodynamic and Foundation Interaction Effects: by Chopra, A.K.,Chakrabarti, P. and Gupta, S., January 1980, (AD-A087297)AI0.

-Rocking Response of Rigid Blocks to Earthquakes: by Yim, e.S., Chopra, A.K. and Penzien, J., January 1980, (PB80 166 002)A04.

-Optimum Inelastic Design of Seismic-Resistant Reinforced Concrete Frame Structures: by Zagajeski, S.W. and Bertero, V.V., January1980, (PB80 164 635)A06.

-Effects of Amount and Arrangement of Wall-Panel Reinforcement on Hysteretic Behavior of Reinforced Concrete Walls: by I1iya, R.and Bertero, V.V., February 1980, (PB81 122 525)A09.

"Shaking Table Research on Concrete Dam Models: by Niwa, A. and Clough, R.W., September 1980, (PB81 122368)A06.

-The Design of Steel Energy-Absorbing Restrainers and their Incorporation into Nuclear Power Plants for Enhanced Safety (VoIla):Piping with Energy Absorbing Restrainers: Parameter Study on Small Systems: by Powell, G.H., Oughourlian, e. and Simons, J., June1980.

"Inelastic Torsional Response of Structures SUbjected to Earthquake Ground Motions: by Yamazaki, Y., April 1980, (PB8 I 122327)A08.

UCB/EERC-80108 "Study of X-Braced Steel Frame Structures under Earthquake Simulation," by Ghanaat, Y., April 1980, (PB8 I 122 335)A I I.

UCB/EERC-80109 "Hybrid Modelling of Soil-Structure Interaction: by Gupta, S., Lin, T.W. and Penzien, J., May 1980, (PB81 122 319)A07.

UCB/EERC-80/10 "General Applicability of a Nonlinear Modcl of a One Story Steel Frame: by Sveinsson, B.I. and McNiven, RD., May 1980, (PB81124877)A06.

UCB/EERC-80102

UCB/EERC-80103

UCB/EERC-80/11

UCB/EERC-80112

UCB/EERC-80/13

UCB/EERC-80/14

"A Green-Function Method for Wave Interaction with a Submerged Body," by Kioka, W., April 1980, (PB81 122269)A07.

-Hydrodynamic Pressure and Added Mass for Axisymmetric Bodies.," by Nilrat, F., May 1980, (PB81 122343)A08.

"Treatment of Non-Linear Drag Forces Acting on Offshore Platforms: by Dao, B.V. and Penzien, J., May 1980, (PB81 153 413)A07.

"2D Plane/Axisymmetric Solid Element (Type 3-Elastic or Elastic-Perfectly Plastic)for the ANSR-IIProgram: by Mondkar, D.P. andPowell, G.H., July 1980, (PB81 122 350)A03.

UCB/EERC-801l5 -A Response Spectrum Method for Random Vibrations: by Ocr Kiureghian, A., June 1981, (PB81 122 301)A03.

UCB/EERC-80116 "Cyclic Inelastic Buckling of Tubular Steel Braces," by Zayas, V.A., Popov, E.P. and Mahin, SA., June 1981, (PB81 124 885)AIO.

UCB/EERC-8011 7 -Dynamic Response of Simple Arch Dams Including Hydrodynamic Interaction,- by Porter, e.s. and Chopra, A.K., July 1981, (PB8 I124000)AI3.

UCB/EERC-80/18 "Experimental Testing of a Friction Damped Aseismic Base Isolation System with Fail-Safe Characteristics: by. Kelly, J .M., Beucke,K.E. and Skinner, M.S., July 1980, (PB8l 148 595)A04.

UCB/EERC-80/19 "The Design of Steel Energy-Absorbing Restrainers and their Incorporation into Nuclear Power Plants for Enhanced Safety (VoUB):Stochastic Seismic Analyses of Nuclear Power Plant Structures and Piping Systems Subjected to Multiple Supported Excitations," byLee, M.e. and Penzien, J., June 1980, (PB82 201 872)A08.

UCB/EERC-80/20 -The Design of Stee! Energy-Absorbing Restrainers and their Incorporation into Nuclear Power Plants for Enhanced Safety (Vol IC):Numerical Method for Dynamic Substructure Analysis," by Dickens, J.M. and Wilson, E.L., June 1980.

UCB/EERC-80/21 "The Design of Steel Energy-Absorbing Restrainers and their Incorporation into Nuclear Power Plants for Enhanced Safety (Vol 2):Development and Testing of Restraints for Nuclear Piping Systems," by Kelly, J.M. and Skinner, M.S., June 1980.

UCB/EERC-80/22 "3D Solid Element (Type 4-Elastic or Elastic-Perfectly-Plastie) for the ANSR-II Program," by Mondkar, D.P. and Powell, G.H., July1980, (PB81 123 242)A03.

UCB/EERC-80123 "Gap-Friction Element (Type 5) for the Ansr-II Program," by Mondkar, D.P. and Powell, G.H., July 1980, (PB81 122285)A03.

UCB/EERC-80/24 "U-Bar Restraint Element (Type II) for the ANSR-II Program," by Oughourlian, C. and Powell, G.H., July 1980, (PB81 122 293)A03.

UCB/EERC-80/25 "Testing of a Natural Rubber Base Isolation System by an Explosively Simulated Earthquake," by Kelly, J.M., August 1980, (PB81 201360)A04.

UCB/EERC-80/26 "Input Identification from Structural Vibrational Response," by Hu, Y., August 1980, (PB81152 308)A05.

UCB/EERC-80127 "Cyclic Inelastic Behavior of Steel Offshore Structures," by Zayas, V.A., Mahin, S.A. and Popov, E.P., August 1980, (PB81 196180)AI5.

UCB/EERC-80/28 -Shaking Table Testing of a Reinforced Concrete Frame with Biaxial Response: by Oliva, M.G., October 1980, (PB81 154 304)AI0.

UCB/EERC-80/29 "Dynamic Properties of a Twelve-Story Prefabricated Panel Building," by Bouwkamp, J.G., Kollegger, J.P. and Stephen, R.M., October1980, (PB82 138 777)A07.

UCB/EERC-80/30 "Dynamic Properties of an Eight-Story Prefabricated Panel Building," by Bouwkamp, J.G., Kollegger, J.P. and Stephen, R.M., October1980, (PB81 200 313)A05.

UCB/EERC-80/31 "Predictive Dynamic Response of Panel Type Structures under Earthquakes," by Kollegger, J.P. aI)d Bouwkamp, J.G., October 1980,(PB81 152 316)A04.

UCB/EERC-80/32 -The Design of Steel Energy-Absorbing Restrainers and their Incorporation into Nuclear Power Plants for Enhanced Safety (Vol 3):Testing of Commercial Steels in Low-Cycle Torsional Fatigue," by Spanner, 1'., Parker, E.R., Jongewaard, E. and Dory, M., 1980.

Preceding page blank -201-

Page 216: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

UCB/EERC-SI1I0

UCB/EERC-SI/05

UCB/EERC-SO/41

UCB/EERC-80/36

UCB/EERC-SO/35

UCB/EERC-SO/33

UCB/EERC-80/42

UCB/EERC-SO/34

UCB/EERC-81!07

UCB/EERC-S1!04

UCB/EERC-SI/03

UCB/EERC-SO/37

UCB/EERC-SO/3S

UCB/EERC-80/39

UCB/EERC-81/02

UCB/EERC-SO/40

UCB/EERC-SO/43

UC'B/EERC-SI/OI

UCB/EERC-SI/06

"The Design of Steel Energy-Absorbing Restrainers and their Incorporation into Nuclear Power Plants for Enhanced Safcty (Vol 4):Shaking Table Tests of Piping Systcms with Energy-Absorbing Restrainers," by Stiemer, S.F. and Godden, W.G., September 19S0,(PBS2 201 SSO)/\05.

"The Design of Steel Energy-Absorbing Restrainers and thcir Incorporation into Nuclear Power Plants for Enhanced Safety (Vol 5):Summary Report," by Spencer, 1'., 19S0.

"Experimental Testing of an Encrgy-Absorbing Base Isolation System," by Kelly, J.M., Skinner, M.S. and Beucke, K.E., Oetober 19S0,(PBS I 154 On)A04.

"Simulating and Analyzing ArtifIcial Non-Stationary Earth Ground Motions," by Nau, R.F., Oliver, R.M. and Pister, K.S., October19S0, (PBS I 153 397)A04.

"Earthquake Engineering at Berkeley - 19S0," by , September 19S0, (PBS I 205 674)A09.

"Inelastic Seismic Analysis of Large Panel Buildings," by Schricker, V. and Powell, G.H., September 19S0, (PBSI 154 33S)AI3.

"Dynamic Response of Embankment, Concrete-Gavity and Arch Dams Including Hydrodynamic Interation,- by Hall, J.F. and Chopra,A.K., October 19S0, (PBS I 152 324)Al1.

"Inelastic Buckling of Steel Struts undcr Cyclic Load Reversal.: by Black, R.G., Wenger, W.A. and Popov, E.P., October 19S0, (PBSI154312)A08.

"Influence of Site Characteristics on Buildings Damage during the October 3,1974 Lima Earthquake: by Repetto, 1'., Arango, I. andSeed, H.B., September 1980, (PB81 161 739)A05.

"Evaluation of a Shaking Table Test Program on Response Behavior of a Two Story Reinforced Concrete Frame." by Blondet, J.M.,Clough, R.W. and Mahin, SA, December 1980, (I'B82 196 544)AII.

"Modelling of Soil-Structure Interaction by Finite and Infinite Elements," by Medina, F., December 1980, (PB81 229 270)A04.

"Control of Seismic Response of Piping Systems and Other Structures by Base Isolation," by Kelly, J.M., January 1981, (PB81 200735)A05.

,"OPTNSR- An Interactive Software System for Optimal Design of Statically and Dynamically Loaded Structures with NonlinearResponse,- by Bhatti, M.A., Ciampi, V. and Pister, K.S., January 1981, (PB81 218 851)A09.

"Analysis of Local Variations in Free Field Seismic Ground Motions," by Chen, J.-c., Lysmer, J. and Seed, RB., January 1981, (AD­A099508)A13.

"Inelastic Structural Modeling of Braced Offshore Platforms for Seismic Loading," by Zayas, V.A., Shing, P.-S.B., Mahin, S.A. andPopov, E.I'., January 1981, (I'B82 138 777)A07.

"Dynamic Response of Light Equipment in Structures," by Der Kiureghian, A., Sackman, J.L. and Nour-Omid, B., April 1981, (PB81218497)A04.

"Preliminary Experimental Investigation of a Broad Base Liquid Storage Tank: by Bouwkamp, J.G., Kollegger, J.P. and Stephen, R.M.,May 1981, (I'B82 140 385)A03.

"The Seismic Resistant Design of Reinforced Concrete Coupled Structural Walls: by Aktan, A.E. and Bertero, V.V., June 1981, (PB82113358)AII.

"Unassigned," by Unassigned, 1981.

-Experimental Behavior of a Spatial Piping System with Steel Energy Absorbers Subjected to a Simulated Differential Seismic Input," byStiemer, S.F., Godden, W.G. and Kelly, J.M., July 1981, (PB82 201 898)A04.

"Evaluation of Seismic Design Provisions for Masonry in the United States," by Sveinsson, RI., Mayes, R,L. and McNiven, H,D.,August 1981, (I'B82 166 075)A08.

"Two-Dimensional Hybrid Modelling of Soil-Structure Interaction," by Tzong, T.-J., Gupta, S. and Penzien, J., August 1981, (PB82 142118)A04.

UCB/EERC-81/12 "Studies on Effects of InfIlIs in Seismic Resistant RIC Construction: by Brokken, S. and Bertero, V.V., October 1981, (PBS2 166190)A09. .

UCB/EERC-SI/08

UCB/EERC-SI/09

UCB/EERC-Sl/11

UCB/EERC-SI/13 "Linear Models to Prcdict the Nonlinear Seismic Behavior of a One-Story Steel Frame," by Valdimarsson, H., Shah, A.R andMcNiven, H.D., September 1981, (PBS2 13S 793)A07.

UCB/EERC-SI/14 "TLUSH: A Computer Program for the Three-Dimensional Dynamic Analysis of Earth Dams," by Kagawa, T., Mejia, L.R, Seed, RB.and Lysmer, J., September 19SI, (PBS2 139 940)A06.

UCB/EERC-81/15 "Three Dimensional Dynamic Response Analysis of Earth Dams," by Mejia, L.H. and Seed, RB., September 1981, (PB82 137 274)AI2.

UCB/EERC-81!16 "Experimental Study of Lead and Elastomeric Dampers for Base isolation Systems," by Kelly, J.M. and Hodder, S.B., October 1981,(PB82 166 IS2)A05.

UCB/EERC-81/17 "The Influence of Base Isolation on the Seismic Response of Light Secondary Equipment," by Kelly, J.M., April 1981, (PB82 255266)A04.

UCB/EERC-81!18 "Studies on Evaluation of Shaking Table Response Analysis Procedures," by Blondet, J. M., November 1981, (PB82 197 278)AI0.

UCB/EERC-81/19 "DELIGHT.STRUCT: A Computer-Aided Design Environment for Structural Engineering," by Balling, RJ., Pister, K.S. and Polak, E.,December 1981, (PB82 218 496)A07. .

UCB/EERC-81/20 "Optimal Design of Seismic-Resistant Planar Steel Frames,- by Balling, R.J., Ciampi, V. and Pister, KS., December 1981, (PB82 220179)A07.

UCB/EERC-S2/01 "Dynamic Behavior of Ground for Seismic Analysis of Lifeline Systems,- by Sato, T. and Der Kiureghian, A., January 1982, (PB82 218926)A05.

UCB/EERC-82/02 "Shaking Table Tests of a Tubular Steel Frame Model," by Ghanaat, Y. and Clough, RW., January 1982, (PB82 220 161)A07.

UCB/EERC-82/03 "Behavior of a Piping System under Seismic Excitation: Experimental Investigations of a Spatial Piping System supported by Mechani­cal Shock Arrestors," by Schneider, S., Lee, H."M. and Godden, W. G., May 1982, (PB83 In 544)A09.

-202-

Page 217: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

UCB/EERC-82/04

UCB/EERC-82/05

UCB/EERC-82/06

UCB/EERC-82/07

UCB/EERC-82/08

UCB/EERC-82109

UCB/EERC-82/ to

UCB/EERC-82/11

UCB/EERC-82/12

UCB/EERC-82/13

UCB/EERC-82/14

UCB/EERC-82/15

UCB/EERC-82/16

UCB/EERC-821l7

UCB/EERC-82/IB

UCB/EERC-82/19

UCB/EERC·82120

UCB/EERC·B2/21

UCB/EERC·82122

UCB/EERC·82/23

UCB/EERC-82/24

UCB/EERC-82/25

UCB/EERC-82/26

UCB/EERC-82/27

UCBIEERC-83101

UCBIEERC-83/02

UCB/EERC-83/03

UCBIEERC-83/04

UCB/EERC-83105

UCBIEERC·83/06

UCB/EERC-83/07

UCB/EERC-83108

UCB/EERC-83/09

UCB/EERC-83/tO

UCB/EERC-B3/11

UCB/EERC-B3/12

UCB/EERC·B3/13

UCBIEERC-83/14

'New Approaches for the Dynamic Analysis ofL,rge Structural Systems: by Wilson, E.L., June 1982, (PB83 148 080)A05.

"Model Study of Effects of Damage on the Vibration Properties of Steel Offshore Platforms," by Shahrivar, F. and Bouwkamp, J.G.,June 1982, (PB83 148 742)AtO.

'States of the Art and Pratice in the Optimum Seismic Design and Analytical Response Prediction of RIC Frame Wall Structures," byAktan, A.E. and Bertero, V.V., July 1982, (PB83 147 736}A05.

"Further Study of the Earthquake Rcsponse of a Broad Cylindrical Liquid-Storage Tank Model: by Manos, G.C. and Clough, R.W.,July 1982, (PB83 147 744}AII.

"An Evaluation of the Design and Analytical Seismic Response of a Seven Story Reinforced Concrete Frame: by Charney, F.A. andBertero, V.V., July 1982, (PB83 157 628)A09.

"Fluid-Structure Interactions: Added Mass Computations for Incompressible Fluid: by Kuo, J.S.-H., August 1982, (PB83 156 281)A07.

"Joint-Opening Nonlinear Mechanism: Interface Smeared Crack Model: by Kuo, J.S.-H., August 1982, (PB83 149 195)A05.

"Dynamic Response Analysis of Techi Dam," by Clough, R.W., Stephen, R.M. and Kuo, J.S.-H., August 1982, (PBB3 147 496)A06.

"Prediction of the Seismic Response of RIC Frame-Coupled Wall Structures: by Aktan, A.E" Bertero, V.V. and Piazzo, M., August1982, (PB83 149 203)A09.

"Preliminary Report on the Smart I Strong Motion Array in Taiwan: by Bolt, B.A., Loh, C.H., Penzien, J. and Tsai, Y.B., August1982, (PB83 159 400}AtO.

"Shaking-Table Studies of an Eccentrically X-Braced Steel Structure," by Yang, M.S., September 1982, (PB83 260 778)AI2.

'The Performance of Stairways in Earthquakes: by Roha, c., Axley, J.W. and Bertero, V.V., September 1982, (PB83 157 693)A07.

"The Behavior of Submerged MUltiple Bodies in Earthquakes," by Liao, W.-G., September 1982, (PB83 158 709)A07.

"Effects of Concrete Types and Loading Conditions on Local Bond-Slip Relationships: by Cowell, A.D., Popov, E.P. and Bertero, V.V.,September 1982, (PB83 153 577)A04.

-Mechanical Behavior of Shear Wall Vertical Boundary Members: An Experimental Investigation: by Wagner, M.T. and Bertero, V.V.,October 1982, (PB83 159 764)A05.

"Experimental Studies of Multi-support Seismic Loading on Piping Systems;' by Kelly, J.M. and Cowell, A.D., November 1982.

-Generalized Plastic Hinge Concepts for 3D Beam-Column Elements," by Chen, P. F.-S. and Powell, G.H., November 1982, (PB83 247981)AI3.

-ANSR-ll: General Computer Program for Nonlinear Structural Analysis: by Oughourlian, COV. and Powell, G.H., November 1982,(PB83 251 330)AI2.

"Solution Strategies for Statically Loaded Nonlinear Structures," by Simons, J.W. and Powell, G.H., November 1982, (PB83 197970)A06.

"Analytical Model of Deformed Bar Anchorages under Generalized Excitations; by Ciampi, V., Eligehausen, R., Bertero, V,V. andPopov, E.P., November 1982, (PB83 169 532)A06.

"A Mathematical Model for the Response of Masonry Walls to Dynamic Excitations: by Sucuog!u, H., Mengi, Y. and McNiven, H.D.,November 1982, (PB83 169011 )A07.

"Earthquake Response Considerations of Broad Liquid Storage Tanks: by Cambra, F.J., November 1982, (PB83 251 215)A09.

"Computational Models for Cyclic Plasticity, Rate Dcpendence and Creep," by Mosaddad, B. and Powell, G.H., November 1982, (PB83245 829)A08.

"Inelastic Analysis of Piping and Tubular Structures, - by Mahasuverachai, M. and Powell, G.H., November 1982, (PB83 249 987)A07.

"The Economic Feasibility of Seismic Rehabilitation of Buildings by Base Isolation: by Kelly, J.M., January 1983, (PB83 197 988)A05.

"Seismic Moment Connections for Moment-Resisting Steel Frames.: by Popov, E.P., January 1983, (PB83 195 412)A04.

"Design of Links and Beam-to-Column Connections for Eccentrically Braced Steel Frames," by Popov, E.P. and Malley, J.O., January1983, (PB83 194 811 )A04.

"Numerical Techniques for the Evaluation of Soil-Structure Interaction Effccts in the Time Domain: by Bayo, E. and Wilson, E,L.,February 1983, (PB83 245 605)A09.

"A Transducer for Measuring the Internal Forces in the Columns of a Frame-Wall Reinforced Concrete Structure: by Sause, R. andBertero, V. V., May 1983, (PB84 119 494)A06.

"Dynamic Interactions Between Floating Ice and Offshore Structures," by Croteau, P., May 1983, (PB84 119 486}A16.

"Dynamic Analysis of Multiply Tuned and Arbitrarily Supported Secondary Systems: by Igusa, T. and Der Kiureghian, A., July 1983,(PB84 118 272)AII.

"A Laboratory Study of Submerged Multi-body Systems in Earthquakes," by Ansari, G.R., June 1983, (PB83 261 842)AI7.

"Effects of Transient Foundation Uplift on Earthquake Response of Structures: by Yim, c.-S. and Chopra, AX., June 1983, (PB83 261396)A07.

"Optimal Design of Friction-Braced Frames under Seismic Loading: by Austin, M.A. and Pister, K.S., June 1983, (PB84 119 288)A06.

"Shaking Table Study of Single-Story Masonry Houses: Dynamic Performance under Three Component Seismic Input and Recommen­dations: by Manos, G.c., Clough, R.W. and Mayes, R.L., July 1983, (UCB/EERC-83/11)A08.

"Experimental Error Propagation in Pseudodynamic Testing," by Shiing, P.B. and Mahin, S.A., June 1983, (PB84 119 270)A09.

"Experimental and Analytical Predictions of the Mechanical Characteristics of a 1/5-scale Model of a 7-story RIC Frame-Wall BuildingStructure: by Aktan, A.E., Bertcro, V.V., Chowdhury, A.A. and Nagashima, T., June, 1983, (PB84 119 213)A07.

·Shaking Table Tests of Largc·Panel Prceast Concrcte Building Systcm Asscmblages," by Oliva, M.G. and Clough, R.W., June 1983,(PB86 110 210IAS)AII.

-203-

Page 218: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

UCB/EERC-83/15 "Seismic Behavior of Active Beam Links in Eccentrically Braced Frames," by Hjelmstad, K.D. and Popov, E.P., July 1983, (PB84 119676)A09.

UCB/EERC-83/16 "System Identification of Structures with Joint Rotation," by Dimsdale, J.S., July 1983, (PB84 192 2IO)A06.

UCB/EERC-83/17 "Construction of Inelastic Response Spectra for Single-Degree-of-Freedom Systems," by Mahin, S. and Lin, J., June 1983, (PB84 208834)A05.

UCB/EERC-83/18 -Interactive Computer An~lysis Methods for Predicting the Inelastic Cyclic Behaviour of Structural Sections: by Kaba, S. and Mahin,S., July 1983, (PB84 192 012)A06.

UCB/EERC-83/19 -Effects of Bond Deterioration on Hysteretic Behavior of Reinforced Concrete Joints," by Filippou, F.e., Popov, E.P. and Bertero, V.V.,August 1983, (PB84 192 020)AIO.

UCB/EERC-83/20 -Correlation of Analytical and Experimental Responses of Large-Panel Precast Building Systems," by Oliva, M.G., Clough, R.W., Vel­kov, M. and Gavrilovic, P., May 1988.

UCB/EERC-83/21 "Mechanical Characteristics of Materials Used in a 1/5 Scale Model of a 7-Story Reinforced Concrete Test Structure;' by Bertero, V.V.,Aktan, A.E., Harris, H.G. and Chowdhury, A.A., October 1983, (PB84 193 697)A05.

UCB/EERC-83/22 "Hybrid Modelling of Soil-Structure Interaction in Layered Media," by Tzong, T.-J. and Penzien, J., October 1983, (PB84 192 I78)A08.

UCB/EERC-83/23 "Local Bond Stress-Slip Relationships of Deformed Bars' under Generalized Excitations: by Eligehausen, R., Popov, E.P. and Bertero,V.V., October 1983, (PB84 192 848)A09.

UCB/EERC-83/24 "Design Considerations for Shear Links in Eccentrically Braced Frames;' by Malley, J.O. and Popov, E.P., November 1983, (PB84 192I86)A07.

UCB/EERC-84/01 -Pseudodynamic Test Method for Seismic Performance Evaluation: Theory and Implementation," by Shing, P.-S.B. and Mahin, S.A.,January 1984, (PB84 190 644)A08.

UCB/EERC-84/02 "Dynamic Response Behavior of Kiang Hong Dian Dam," by Clough, R.W., Chang, K.-T., Chen, H.-Q. and Stephen, R.M., April 1984,(PB84 209 402)A08.

UCB/EERC-84/03 "Refined Modelling of Reinforced Concrete Columns for Seismic Analysis:' by Kaba, S.A. and Mahin, SA, April 1984, (PB84 234384)A06.

UCB/EERC-84/04 "A New Floor Response Spectrum Method for Seismic Analysis of Multiply Supported Secondary Systems," by Asfura, A. and DerKiureghian, A.. June 1984, (I'B84 239 417)A06.

UCB/EERC-84/05 "Earthquake Simulation Tests and Associated Studies of a I/Sth-scale Model of a 7-Story RIC Frame-Wall Test Structure," by Bertero,V.V., Aktan, A.E., Charney, F.A. and Sause, R., June 1984, (PB84 239 409)A09.

UCB/EERC-84/06 "RIC Structural Walls: Seismic Design for Shear:' by Aktan, A.E. and Bertero, V.V., 1984.

UCB/EERC-84/07 "Behavior of Interior and Exterior Flat-Plate Connections subjected to Inelastic Load Reversals," by Zee, H.L. and Moehle, J.P., August1984, (PB86 117 629/AS)A07.

UCB/EERC-84/08 "Experimental Study of the Seismic Behavior of a Two-Story Flat-Plate Structure," by Moehle, J.P. and Diebold, J.W., August 1984,(PB86 122 S53/AS)AI2.

UCB/EERC-84/09 "Phenomenological Modeling of Steel Braces under Cyclic Loading," by Ikeda, K., Mahin, SA and Dermitzakis, S.N., May 1984, (PB86132 198/AS)A08.

UCB/EERC-84/1O "Earthquake Analysis and Response of Concrete Gravity Dams," by Fcnves, G. and Chopra, A.K., August 1984, (PB8S 193902/AS)A II.

UCB/EERC-84/11 "EAGD-84: A Computer Program for Earthquake Analysis of Concrete Gravity Dams," by Fenves, G. and Chopra, A.K., August 1984,(pB85 193 613/AS)A05.

UCB/EERC-841l2 "A Refined Physical Theory Model for Predicting the Seismic Behavior of Braced Steel Frames: by Ikeda, K. and Mahin, S.A., JUly1984, (PB85 191 450/AS)A09.

UCB/EERC-84/13 "Earthquake Engineering Research at Berkeley - 1984," by, August 1984, (PB8S 197 341/AS)AI0.

UCB/EERC-84/14 "Moduli and Damping Factors for Dynamic Analyses of Cohesionlcss Soils;' by Seed, H.B., Wong, R.T., Idriss, I.M. and Tokimatsu, K.,September 1984, (PB85 191 468/AS)A04.

UCB/EERC-84115 "The Influence of SPT Procedures in Soil Liquefaction Resistance Evaluations," by Seed, H.B., Tokimatsu, K., Harder, L.F. and Chung,R.M., October 1984, (PB85 191 732/AS)A04.

UCB/EERC-84/16 "Simplified Procedures for the Evaluation of Settlements in Sands Due to Earthquake Shaking: by Tokimatsu, K. and Seed, H.B.,October 1984, (PB85 197 887/AS)A03.

UCB/EERC-84117 -Evaluation of Energy Ahsorption Charactcristics of Highway Bridges Under Seismic Conditions - Volume I and Volume II(Appendices)," by Imbsen, R.A. and I'enzien, J., September 1986.

UCB/EERC-84118 "Structure-Foundation Interactions under Dynamic Loads," by Liu, W.D. and Pcnzien, J., November 1984. (PB87 124 889/AS)AII.

UCBfEERC-84/19 "Seismic Modelling of Deep Foundations," by Chen, C.-H. and Penzien, J., November 1984, (PB87 124 798/AS)A07.

UCBfEERC-84/20 "Dynamic Response Behavior of Quan Shui Dam," by Clough, R.W., Chang, K.-T., Chen, H.-Q., Stephen, R.M., Ghanaat, Y. and Qi,J.-H., November 1984, (I'B86 115177/AS)A07.

UCB/EERC-85101 "Simplified Methods of Analysis for Earthquake Resistant Design of Buildings," by Cruz, E.F. and Chopra, A.K., February 1985, (PB86II2299/AS)AI2.

UCB/EERC-8SI02 "Estimation of Seismic Wave Coherency and Rupture Velocity using the SMART I Strong-Motion Array Recordings," by Abrahamson,N.A., March 1985, (PB86 214 343)A07.

UCB/EERC-8S/03 "Dynamic Properties of a Thirty Story Condominium Tower Building." by Stephen, R.M., Wilson, E.L. and Stander, N" April 1985,(PB86 II 896SfAS)A06.

UCB/EERC-85104 "Development of Substructuring Techniqucs for On-Line Computer Control/cd Seismic Performance Testing," by Dcrmitzakis, S. andMahin, S., February 1985, (PB86 1329411~S)A08.

UCBfEERC-8S/OS "A Simple Model for Reinforcing Bar Anchorages under Cyclic Excitations:' by Filippou, Fe., March 1985, (I'B86 112 919/AS)A05.

-204-

Page 219: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

UCB/EERC-85/06

UCB/EERC-85/07

UCB/EERC-85/08

UCB/EERC-85/09

UCB/EERC-85/1O

UCB/EERC-85/11

UCB/EERC-85/12

UCB/EERC-85/13

UCB/EERC-85/14

UCB/EERC-85/15

UCB/EERC-85/16

UCB/EERC-86/01

UCB/EERC-86/02

UCB/EERC-86/03

UCB/EERC-86/04

UCB/EERC-86/05

UCB/EERC-86/06

UCB/EERC-86/07

UCB/EERC-86/08

UCB/EERC-86/09

UCB/EERC-86/IO

UCB/EERC-86/ll

UCB/EERC-86/12

UCB/EERC-87/O I

UCB/EERC-87/02

UCB/EERC-87/03

UCB/EERC-87/04

UCB/EERC-87/05

UCB/EERC-87/06

UCB/EERC-87/07

UCB/EERC-87/08

UCB/EERC-87109

UCB/EERC-87/1 0

UCB/EERC-87/11

UCB/EERC-87/12

UCB/EERC-87/13

UCB/EERC-87/14

UCB/EERC-87/15

"Racking Behavior of Wood-framed Gypsum Panels under Dynamic Load," by Oliva, M.G., June 1985.

"Earthquake Analysis and Response of Concrete Arch Dams," by Fok, K.-L. and Chopra, A.K., June 1985, (PB86 I39672/AS)AIO.

"Effect of Inelastic Behavior on the Analysis and Design of Earthquake Resistant Structures, - by Lin, J.P. and Mahin, S.A., June 1985,(PB86 135340/AS)A08.

-Earthquake Simulator Testing of a Base-Isolated Bridge Deck," by Kelly, J.M., Buckle, LG. and Tsai, H.-C., January 1986, (PB87 124152/AS)A06.

"Simplified Analysis for Earthquake Resistant Design of Concrete Gravity Dams," by Fenves, G. and Chopra, A.K., June 1986, (PB87124 160/AS)A08.

"Dynamic Interaction Effects in Arch Dams," by Clough, R.W., Chang, K.-T., Chen, H.-Q. and Ghanaat, Y., October 1985, (PB86135027/AS)A05.

"Dynamic Response of Long Valley Dam in the Mammoth Lake Earthquake Series of May 25-27, 1980," by Lai, S. and Seed, H.B.,November 1985, (PB86 142304/AS)A05.

"A Methodology for Computer-Aided Design of Earthquake-Resistant Steel Structures: by Austin, M.A., Pister, K.S. and Mahin, S.A.,December 1985, (PB86 I59480/AS)AIO .

"Response of Tension-Leg Platforms to Vertical Seismic Excitations," by Liou, G.-S., Penzien, J. and Yeung, R.W., December 1985,(PB87 12487I/AS)A08.

"Cyelic Loading Tests of Masonry Single Piers: Volume 4 - Additional Tests with Height to Width Ratio of I," by Sveinsson, B.,McNiven, H.D. and Sucuoglu, H., December 1985.

"An Experimental Program for Studying the Dynamic Response of a Steel Frame with a Variety of Infill Partitions," by Yaney, B. andMeNiven, H.D., December 1985.

"A Study of Seismically Resistant Eccentrically Braccd Steel Frame Systems," by Kasai, K. and Popov, E.!'., January 1986. (PB87 124178/AS)AI4.

"Design Problems in Soil Liquefaction," by Seed, H.B., Fcbruary 1986, (PB87 124 I86/AS)A03.

"Implications of Recent Earthquakes and Research on Earthquake-Resistant Design and Construction of Buildings," by Bcrtero, V.V.,March 1986, (PB87 124 194/AS)A05.

"The Use of Load Dependent Vectors for Dynamic and Earthquake Analyses: by Leger, P., Wilson, E.L. and Clough, R.W., March1986, (PB87 124 202/AS)AI2.

"Two Beam-To-Column Web Connections," by Tsai, K.-e. and Popov, E.P., April 1986, (PB87 124 301/AS)A04.

"Dctermination of Penetration Resistance for Coarsc-Grained Soils using the Becker Hammer Drill: by Harder, L.F. and Seed, H.B.,May 1986, (PB87 124 210/AS)A07.

"A Mathematical Model for Predicting the Nonlinear Response of Unreinforced Masonry Walls to In-Plane Earthquake Excitations: byMengi, Y. and McNiven, HD.. May 1986, (PB87 124 780/AS)A06.

"The 19 September 1985 Mexico Earthquake: Building Behavior," by Bertero, V.V., July 1986.

"EACD-3D: A Computer Program for Three-Dimensional Earthquake Analysis of Concrete Dams: by Fok, K.-L., Hall, J.F. andChopra, AX., July 1986, (PB87 124 228/AS)A08.

"Earthquake Simulation Tests and Associated Studies of a 0.3-Scale Model of a Six-Story Concentrically Braccd Steel Structure," byUang, C.-M. and Bertero, V.V., December 1986, (PB87 163 564/AS)AI7.

"Mechanical Characteristics of Base Isolation Bearings for a Bridge Deck Model Test," by Kelly, J.M., Buckle, I.G. and Koh, c.-G.,November 1987.

"Effects of Axial Load on Elastomeric Isolation Bearings," by Koh, c.-G. and Kelly, J.M., November 1987.

"The FPS Earthquake Resisting System: Experimental Report," by Zayas, V.A., Low, S.S. and Mahin, SA., June 1987.

"Earthquake Simulator Tests and Associated Studies of a 0.3-Scale Model of a Six-Story Eccentrically Braced Steel Structure," by Whit­taker, A., Uang, e.-M. and Bertero, V.V.. July 1987.

"A Displacement Control and Uplift Restraint Device for Base-Isolated Structures: by Kelly, J.M.. Griffith, M.e. and Aiken, I.D., April1987.

"Earthquake Simulator Testing of a Combincd Sliding Bearing and Rubber Bearing Isolation System: by Kelly, J.M. and Chalhoub,M.S., 1987.

'Three-Dimensional Inelastic Analysis of Reinforced Concrete Frame-Wall Structures," by Moazzami, S. and Bertero, V.V., May 1987.

"Experiments on Eccentrically Braced Frames with Composite Floors," by Rieles, J. and Popov, E., June 1987.

-Dynamic Analysis of Seismically Resistant Eccentrically Braced Frames: by Rieles, J. and Popov, E., June 1987.

"Undrained Cyelie Triaxial Testing of Gravels-The Effect of Membrane Compliance," by Evans, M.D. and Seed, H.B., July 1987.

"Hybrid Solution Techniqucs for Generalized Pseudo-Dynamic Testing." by Thewalt, C. and Mahin, S.A., July 1987.

"Ultimate Behavior of Butt Welded Splices in Heavy Rolled Steel Sections," by Bruneau, M., Mahin, S.A. and Popov, E.P., July 1987.

"Residual Strength of Sand from Dam Failures in the Chilean Earthquake of March 3, 1985," by De Alba, 1'.. Seed, 1-1.1l., Retamal, E.and Seed, R.B., September 1987.

"Inelastic Seismic Response of Structures with Mass or Stiffness Eccentricities in Plan," by Bruneau, M. and Mahin, S.A.. September1987.

"CSTRUCT: An Interactive Computer Environment for the Design and Analysis of Earthquake Resistant Steel Structures," by Austin,M.A., Mahin, SA. and Pister, K.S., September 1987.

"Experimental Study of Reinforced Concrete Columns Subjected to Multi-Axial Loading," by Low, S.S. and Moehle, J.I' .. September1987.

"Relationships between Soil Conditions and Earthquake Ground Motions in Mexico City in the Earthquake of Sept. 19, 1985," by Seed,H.B.. Romo. M.P.. Sun, J., Jaime.. A. and Lysmer, J., October 1987.

-205-

Page 220: EXPERIMENTAL STUDIES OF A SINGLE STORY …Release Unlimited 19. Security Class (This Report) unclassified 20. Security Class (This Page) unclassified 21. No. of Pages 217 22. Price

UCB/EERC-87fl6

UCB/EERC-87117

UCB/EERC-87/18

UCB/EERC-87/19

UCB/EERC-87/20

UCB/EERC-87/21

UCB/EERC-87/22

UCB/EERC-88/0 I

UCB/EERC-88/02

UCB/EERC-88/03

UCB/EERC-88/04

UCB/EERC-88/05

UCB/EERC-88/06

UCB/EERC-88/07

UCB/EERC-88/08

VCB/EERC-88/09

UCB/EERC-88/10

UCB/EERC-88111

UCB/EERC-88112

VCB/EERC-88/13

UCB/EERC-88114

UCB/EERC-881l5

VCB/EERC-88/16

VCB/EERC-88/17

VCB/EERe-88118

UCB/EERC-88/19

UCB/EERC-88/20

VCB/EERC-89101

UCB/EERC·89/02

VCB/EERC·89/03

UCB/EERC-89/04

VCB/EERC-89/05

VCB/EERC-89106

VCB/EERC-89/07

VCB/EERC-89/08

UCB/EERC-89/09

VCB/EERC-89/IO

UCB/EERC-89/11

VCBlEERC-89/12

VCB/EERC-89/13

VCB/EERC-89/14

VCB/EERC-89/15

"Experimental Study of Seismic Response of R. e. Setback Buildings,- by Shahrooz, B.M. and Moehle, J.P., Oetober 1987.

"The Effect of Slabs on the Flexural Bchavior of Beams," by Pantazopoulou, SJ. and Moehle, J.P., October 1987.

"Design Procedure for R-FBI Bearings," by Mostaghel, N. and Kelly, J.M., November 1987.

"Analytical Models for Predicting the Lateral Response of R C Shear Walls: Evaluation of their Reliability'- by Vulcano, A. and Ber­tero, V.V., November 1987.

"Earthquake Response of Torsionally-Coupled Buildings," by Hejal, R. and Chopra, A.K., December 1987.

"Dynamic Reservoir Interaction with Monticcllo Dam," by Clough, R.W., Ghanaat, Y. and Qiu, X-F., December 1987.

-Strength Evaluation of Coarse-Grained Soils," by Siddiqi, F.H., Seed, R.B., Chan, e.K., Seed, H.B. and Pyke, R.M., December 1987.

"Seismic Bchavior of ConcentricallY Braccd Steel Frames,- by Khatib, I., Mnhin, S.A. and Pister, K.S., January 1988.

"Experimental Evaluation of Seismic Isolation of Medium-Rise Structures Subject to Uplift.- by Griffith, M.e., Kelly, J.M., Coveney,V.A. and Koh, CG., January 1988.

"Cyclic Behavior of Steel Double Angle Connections," by Astaneh-AsI, A. and Nader, M.N., January 1988.

"Re-evaluation of the Slide in the Lower San Fernando Dam in the Earthqunke of Feb. 9, 1971'- by Seed, H.B., Seed, R.B., Harder,L.F. and long, Il.-L., April 1988.

"Experimental Evaluation of Seismic Isolation of a Nine-Story Braced Steel Frame Suhject to Uplift.- by Griffith, M.C, Kelly, J.M. andAiken, I.D., May 1988.

-DRAIN-2DX User Guide.: by Allahabadi, R. and Powell, G.H., March 1988.

"Cylindrical Fluid Containers in Base-Isolated Structures," by Chalhoub, M.S. and Kelly, J.M. , April 1988.

"Analysis of Near-Source Waves: Separation of Wave Types using Strong Motion Array Recordings,- by Darragh, R.B., June 1988.

"Alternatives to Standard Mode Superposition for Analysis of Non-Classically Damped Systems.- by Kusainov, A.A. and Clough, R.W.,June 1988.

"The Landslide at the Port of Nice on October 16, 1979," by Seed, H.B., Seed, R.B., Schlosser, F., Blondeau, F. and Juran, I., June'1988.

"Liquefaction Potential of Sand Deposits Under Low Levels of Excitation," by Carter, D.P. and Seed, H.B., August 1988.

"Nonlinear Analysis of Reinforced Concrete Frames Under Cyclic Load Reversals'- by Filippou, F.C. and Issa, A., September 1988.

-Implications of Recorded Earthquake Ground Motions on Seismic Design of Building Structures,- by Uang, CoM. and Bertero, V.V.,November 1988.

"An Experimental Study of the Behavior of Dual Steel Systems," by Whittaker, A.S. , Uang, CoM. and Bertero, V.V., September 1988.

"Dynamic Moduli and Damping Ratios for Cohesive Soils,- by Sun, J.I., Golcsorkhi, R. and Seed, RB., August 1988.

"Reinforced Concrete Flat Plates Under Lateral load: An Experimental Study InclUding Biaxial Effects'- by Pan, A. and Moehle, J.,October 1988.

-Earthquake Engineering Research at Berkeley - 1988'- by EERC, November 1988.

"Use of Energy as a Design Criterion in Earthquake-Resistant Design,- by Uang, C.-M. and Bertero, V,V., November 1988.

"Steel Beam-Column Joints in Seismic Moment Resisting Frames," by Tsai, K.-C. and Popov, E.P., November 1988.

"Base Isolation in Japan, 1988," by Kelly, J.M., December 1988.

"Behavior of Long Links in Eccentrically Braced Frames," by Engelhardt, M.D. and Popov, E.P., January 1989.

"Earthquake Simulator Testing of Steel Plate Added Damping and Stiffness Elements: by Whittaker, A., Bertero, V. V., Alonso, J. andThompson, c., January 1989.

"Implications of Site Effects in the Mexico City Earthquake of Sept. 19, 1985 for Earthquake-Resistant Design Criteria in the San Fran­cisco Bay Area of California, " by Seed, H.B. and Sun, J.I., March 1989.

"Earthquake Analysis and Response of Intake-Outlet Towers," by Goyal, A. and Chopra, A.K., JUly 1989.

-The 1985 Chile Earthquake: An Evaluation of Structural Requirements for Bearing Wall Buildings'- by Wallace, J.W. and Moehle,J.P., July 1989.

"Effects of Spatial Variation of Ground Motions On Largc Multiply-Supported Structures," by Hao, H., July 1989.

"EADAP - Enhanced Arch Dam Analysis Program: Users's Manual: by Ghanaat, Y. and Clough, R.W., August 1989.

-Seismic Performance of Steel Moment Frames Plastically Designed by Least Squares Stress Fields," by Ohi, K. and Mahin, S.A.,August 1989.

"Feasibility and Performance Studies on Improving the Earthquake Resistance of New and Existing Buildings Using the Friction Pendu­lum System," by Zayas, V., Low, S., Mahin, S.A. and Bozzo, L., July 1989.

"Measurement and Elimination of Membrane Compliance Elfects in Undrained Triaxial Testing,- by Seed, R.B., Anwar, R and Nichol­son, P.G., September 1989.

-Static Tilt Behavior ofVnanchored Cylindrical Tanks: by Lau, D.T. and Clough, R.W., September 1989.

"ADAp-88: A Computer Program for Nonlinear Earthquake Analysis of Concrete Arch Dams,- by Fenves, G.L., Mojtahedi, S. and Rei­mer, R.B., September 1989.

"Mechanics of Low Shape Factor Elastomcric Seismic Isolation Bearings," by Aiken, 1.0., Kelly, J .M. and Tajirian, F., December 1989.

"Preliminary Report on the Seismological and Engineering Aspects of the October 17, 1989 Santa Cruz (Lorna Prieta) Earthquake.- byEERC, October 1989.

"Experimental Studies of Single Steel Structure Tested with Flexible, Semi-Rigid and Fixed Connections.- by Nader, M.N. and Astaneh,-Asl, A., August 1989. .

-206-