Prepurchase House Inspection

Sample Report

Executed by: THISNZ Total Home Inspection Services Ltd

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 2: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Inspector's DetailsNameTodd Russell

Mobile021 657 387

Persons in AttendanceInspector and agent

Customer's Details

Agent's Details

Note

· The purpose of the inspection is to identify major current deficiencies that are visuallyidentifiable at the time of the inspection. The report shall include: grounds, structure, exterior,roofs, plumbing, electrical, interior, and insulation/ventilation.· The property report does not include in depth testing of services such as, underfloorheating, specific and specialized heating systems, heat pumps, water pumps, functionality ofany solar power source, swimming pool heating or alike.

NameMr Smith

Street Address

Company Phone

Mobile

Location

Date30 Apr 2014

Time2:00 PM

WeatherFine

Date & Time

Mobile

eMail

Name

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 3: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

GlossaryElectrical / GeneralPlugs, switches and light fittings are sighted where possible for damage or poor fixing back tothe wall linings. Power points are not tested.GoodIs given when the item is believed to be in new or near new condition, or is better than wouldbe expected given the age of the property.Generally GoodUsed as an overall comment to summarise the general condition of the item being checked.Average / ReasonableWhen the condition is at the standard expected given the age of the house. Some wear andtear would be expected but is still in serviceable order.PoorThe condition is below the standard expected. There is damage or excessive wear.Replacement or maintenance is required.HardwareCat doors and window handles, hinges to windows, doors and cupboards.Deck Over LivingDeck built within the exterior wall line. Decked area is often the ceiling of a room or garagebelow.External DeckDeck built outside the exterior wall line. May be cantilevered or attached to the house andsupported on posts or piles.Header TankSmall tank which supplies water to low pressure hot water cylinders, normally located on theroof or in the ceiling space.CladdingExterior wall linings.Gully TrapCollection point outside the building line for waste water. Is connected to the seweragesystem.Water TobyTap or shut off valve usually at the point where the water supply enters the property.Soffit / EavesHorizontal or pitched linings under the roof overhang.FasciaTimber or pre-finished metal facings at the end of the roof line.

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 4: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Moisture Scanning

T.H.I.S Ltd has conducted moisture scanning of the home detailed in this report, whilstperforming a detailed building inspection.

This was NOT a full ingressive survey.

This is a non-invasive method of detecting moisture.

Areas of typical concern such as around windows, around external doors, and along theinterior of exterior walls where accessible, have been scanned with a non-invasive Protimetermoisture meter. This method, combined with the experience and training of our inspector canhelp to ascertain any levels of moisture within the wall cavity.

Levels over 20% are considered high for more modern homes, while older homes can have areading of around this level without concern. The fibre saturation point of older timbers(Rimu, etc.) are higher.

In our experience T.H.I.S Ltd has found that percentage readings can be inaccurate andmisleading.

Skirting boards or gib board linings can show a much higher moisture content than the timberframing behind these areas, giving a misleading indication.

When scanning for moisture T.H.I.S Ltd”s inspector is trained and experienced in looking forother signs of moisture.

These methods combined can give the inspector a good indication of the severity of anymoisture found.

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 5: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Council Property File

LIM REPORT”Land information Memorandum” is a computer generated print out of some of theinformation the council holds on file, mostly pertaining to the “land”. If there are any problemsor unusual important features, these should show up. For instance, the LIM might reveal theproperty is subject to flooding, or contains a council drain which may not be built over, or aprotected tree or building. It should also help you to figure out how the district plan applies tothe site. Sometimes the council will also supply pages of area plans showing the knownstorm water and sewage drains, zoning and other details.

PROPERTY FILEThis is a file that is held at council which contains documents relating to any buildings on thatsite. However, the council only has records of works it knows about. Frequently alterationshave been done to older houses without council knowledge.

RECOMMENDATIONChecking the Council property file for any property is recommended as part of due diligence.This can be done by anyone with an idea of what they are looking for. Alternatively, T.H.I.SLtd, can perform this service on your behalf.

FEESFee for T.H.I.S Ltd to view Council Property File on your behalf.Property Files held at Archives in Wellington require 24hrs notice to access the File and haveit ready for viewing by appointment.Archives Wellington charge a fee for this service.

COMMENT FOR THIS PROPERTYRecommend viewing of Council Building file.

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 6: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Property Landscape and Fixtures

FixturesGarageDouble garage with internal accessCarportNo carport

Clothes LinesExtenda line

Letter BoxFree standing

ShedNo shed

Other

LandscapeDrivewayConcretePathsConcrete

Lawns / GardensGenerally in good conditionRetaining WallsAppear in good condition

Stairs (External)Various types

Outside TapsAll in working order

Retaining walls sold and sound,very little to no movement noted

Older, original rear sectionshowing some age related wearand tear

No concerns

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 7: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Roofing / Roof AreasRoof MaterialTypeTrough section ironFinishPrefinished

Method of InspectionBy getting onto

ConditionGenerally good

CommentComplex junctions well detailed

FasciaTypeTimberConditionAverage

TypeUPVC SpoutingConditionIn average condition

Roof areas solid and sound,very simple, low risk roof design

Small amount of greenery inguttering should be cleared

Penetrations well detailed

Spouting / Guttering

Soffits / EavesTypeHardies Sheet

ConditionAverage

ChimneyTypeSteel flue

CommentAppears sound

Roof AerialTypeAerial/Dish sighted

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 8: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Exterior Cladding / Construction / Wall Cladding1st TypeWeatherboardsFinishPaintConditionGenerally goodCommentWell maintained, better than averageWindow TypePainted timber

Window ConditionGenerally good

Window Head FlashingsAppear to be fitted to all windows

Window CommentWindows appear well detailed and sealed

Minor paint flaking Older original part if home, paintbubbling, still a full membrane,monitor

New joinery installed into olderpart of house, all proper tapeand flashing sighted

Scribers and general weathertightness detailing to a goodstandard

Very low risk single leveldesign, eves all around

Head flashings well detailed

2nd Type

Finish

Condition

Comment

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 9: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Foundations

Perimeter FoundationsTypeConcrete slabConditionAverage

TypeSlatsConditionAverage

Base Cladding

Internal FoundationsTypeConcrete pilesConditionAverage

TypeTimber slatsGround ConditionDry

Ventilation

FlooringTypeConcrete and T&GConditionAverage

PositionOn side of houseCommentGood access

Access Doors

Only common shrinkage andsettlement cracking noted, noconcerns

Good pile to bearer connectionsnoted

Block walls in great condition,no sign of any tanking failures

Type / ConditionNot applicable

CommentsFoundations appear in good order

Bearers / Joists Foundations

30 Apr 2014 | Copyright 2013 THISNZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 10: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Decks

Construction TypeTimber construction

ConditionGenerally good

Handrail ConditionAppears in sound condition

CommentAll appears of solid construction

Timber deck over membrane,no sign of any failure here orunderside. Well protected

Ballastrade guard rail solid andsound, very low risk scenario

Deck over living

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 11: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Services: Security

SecurityBurglar Alarm SystemNone sightedAlarm Control PanelNone sighted

Smoke SensorsYes but not testedSecurity Door LocksPart of hardware

Exterior LightsExterior lights noted

Secutity Window LocksNone sighted

Security LightsSecurity lights noted

Recommend regular testing ofall smoke detectors

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 12: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Services: Electrical

ElectricalPower ConnectionUnder groundMeter Board PositionOutside on wall

Switch Board PositionIn laundry areaSwitch Board TypeCircuit breaker board

Meter Board ConditionAverage for age

No concerns Comms hub. Recommendinstruction from current owner

Board well detailed, well sealedand in good order

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 13: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Services: Plumbing / Drainage

ExternalDrainage Under FloorAppears well supportedGully TrapsIn average condition

Down PipesUPVC systemDriveway / Paving SumpFalls to kerbside drain

Section Run OffNo significiant concerns were visible

Gas Meter (Position)None sighted

Storm WaterAll appears to be working well

Significant plumbing upgradingnoted no undesirable plumbingtypes sighted

Some original copper feeds andwastes in good order

Toby (Position)Front of property

InternalGeneral ConditionCommon condition for age

TypeCombination of Copper and polybutalene

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 14: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Water Heating

Hi capacity system, wellrestrained

Solar water heating system. Recommended discussing withcurrent owner of installingplumber

Water Heating SystemHeader TankNot applicable

Header Tank TrayNot applicable

Water Heating UnitConditionGood condition

Age of Unit2009

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 15: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Kitchen

Kitchen 1

OvenFree standing electricElementsPart of oven electric

Bench TopsFormicaSinksStainless steel

Rangehood / ExtractorNone

TapwareAverage for age

DishwasherYes but not tested

All visible feeds and wastes ingood order. Hot water boilernoted, untested

Very little wear and tear noted

UnitsMelteca

Waste DisposalNo waste disposal

General CommentsGenerally good condition

Moisture Scanning ResultsFluctuations normal

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 16: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Bathroom

Bathroom 1

ShowerOver bathBathAcrylic

TapwareGood conditionHeatingNo heating

Vanity UnitPrefinished type

VentilationNo ventilation

ToiletNo toilet

Good quality finishing anddetailing

All common failure areasexamined, no concerns

General CommentsGenerally good

Moisture Scanning ResultsFluctuations normal

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 17: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Bathroom

Bathroom 2

ShowerUnit typeBathNo bath

TapwareAverage for ageHeatingHeated towel rail

Vanity UnitPrefinished type

VentilationMechanical ventilation to exterior

ToiletDual flush china/acrylic

Whole room in "as new"condition

No concerns

General CommentsGenerally good

Moisture Scanning ResultsFluctuations normal

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 18: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Laundry

Laundry 1Laundry TubSuper tub typeWashing Machine WasteIntegrated into tub

Other FittingsNo other fittings sightedHeatingNo heating

TapwareAverage for age

VentilationPassive window ventilation

Dryer VentVented to exterior

Area in good order Cat door from laundry,magnetic code type?

Tub sealed as per current coderequirements, no concerns

General CommentsGood condition

Moisture Scanning ResultsFluctuations normal

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 19: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Ensuite

Ensuite 1

General Comments<Unrelated Table>

Moisture Scanning Results<Unrelated Table>

ShowerUnit typeBathAcrylic

TapwareGood conditionHeatingElectric wall heater, heated towel rail

Vanity UnitWall mounted custom

VentilationMechanical ventilation to the exterior

ToiletDual flush china/acrylic

Common failure areasexamined, no unusual moisturereadings taken

Wet area junctions well sealed No concerns

General CommentsGenerally good

Moisture Scanning ResultsFluctuations normal

Reference Photos

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 20: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Toilets

Toilet 1

ToiletDual flush china/acrylicVanity UnitNo unit

HeatingNot applicableVentilationPassive window ventilation

TapwareNot applicable

Room in excellent condition.

General CommentsGood condition

Moisture Scanning ResultsFluctuations normal

Reference Photos

<<CheckList_Inspection Date>> | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 21: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Ceiling Cavity

TypeTrussesConditionAverage

TypeFibreglass battsCommentCeiling well covered

Ceiling well covered Truss framing in good order Truss and purlins examined, nomoisture staining noted

Roof StructureNo visible sign

TrimsNo visible sign

Borer

Roof Construction Insulation

Access Hatch VerminTypeTimber lidLocationLaundry

TypeNone sightedCommentNone sighted

Exterior CladdingNone sighted

Sub FloorNo live borer activity noted

Borer CommentsRecommend periodic borer treatment

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 22: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsCarpetCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

Exterior wall scanned for moisture, nounusual fluctuations noted

External DoorsNo external doors

Ventilation / DuctingPassive window ventilation

HeatingNo heating

CommentGenerally good

Moisture ScanningFluctuations normal

Quaility joinery, keep condensation trays andweep holes clear

Picture hooks?, superficial temp repairs

Office

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 23: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsParticle boardCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

Exterior wall scanned for moisture, nounusual fluctuations noted

External DoorsAluminium with glass

Ventilation / DuctingPassive window ventilation

HeatingNo heating

CommentGenerally good

Moisture ScanningFluctuations normal

Protectowrap and foam. Unit properly installed,no concerns. Some small amount of finishingrequired

Rumpus Room

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 24: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsCarpetCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

Log burner in good order, recommendperiodic clean

External DoorsAluminium with glass

Ventilation / DuctingPassive window ventilation

HeatingWood burner

CommentGenerally good

Moisture ScanningFluctuations normal

High weather areas free of any sign of moistureingress or condensation staining

Exterior wall scanned for moisture, nounusual fluctuations noted

Living Area 1

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 25: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsTimber T&GCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsNo internal doors

Common sheet join cracking noted, noconcerns

External DoorsAluminium with glass

Ventilation / DuctingPassive window ventilation

HeatingNo heating

CommentGenerally good

Moisture ScanningFluctuations normal

Exterior wall scanned for moisture, no unusualfluctuations noted

Dining Room

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 26: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsCarpetCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

Exterior wall scanned for moisture, nounusual fluctuations noted

External DoorsNo external doors

Ventilation / DuctingPassive window ventilation

HeatingElectric wall heater

CommentGenerally good

Moisture ScanningFluctuations normal

Filler popping at a few fixing areas, no concerns

Bedroom 1

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 27: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsCarpetCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

If decals are removed, some markings maybe left behind. Info only

External DoorsNo external doors

Ventilation / DuctingPassive window ventilation

HeatingElectric wall heater

CommentGenerally good

Moisture ScanningFluctuations normal

Exterior wall scanned for moisture, no unusualfluctuations noted

Bedroom 2

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 28: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsCarpetCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

Exterior wall scanned for moisture, nounusual fluctuations noted

External DoorsNo external doors

Ventilation / DuctingPassive window ventilation

HeatingElectric wall heater

CommentGenerally good

Moisture ScanningFluctuations normal

House wide. Very good quaility plaster and paintfinish

Bedroom 3

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 29: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

LIVING

Floor CoveringsCarpetCeiling LiningsPainted plaster board

Wall LiningsPainted plaster boardWindow ConstructionAluminium

Internal DoorsHollow core

Unable to determine state if tanking behindthis wall.Note, no damp smells or and evidence oftanking failure

External DoorsNo external doors

Ventilation / DuctingPassive window ventilation

HeatingNo heating

CommentIn average condition

Moisture ScanningFluctuations normal

Scanned whole perimeter, no unusualfluctuations

Bedroom 4

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 30: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Findings / Image Gallery

Large garage, workshop area, very solidlyconstructed, partially lined

Auto door tested ok

Kitchen benchtop should be better sealed to wall Some minor wear and tear noted

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 31: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Findings / Image Gallery

Partial underfloor insulation, under bedrooms,new areas of home solidly constructed, noconcerns

Retrofitted aluminium joinery into existingconcrete area. Joinery well sealed, thoroughlyexamined, inside and out

Pic taken in garage. Gib linings incompleteplastering, no concerns

Store room at rear of garage.Structural retaining wall here appears welltanked, no sign of any moisture leaching frombeyond

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 32: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Findings / Image Gallery

Underside of deck above, can clearly see theformed slopes and falls, no concerns, no sign ofany failure

Good inside to exterior threshold created here,very low risk design, finished well

Small leak at this junction noted at time ofinspection, appears to have been leaking forsome time. Recommed engaging plumber toresolve. Heated water can cause prematuredecay to iron

Retaining walls solid and sound

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 33: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Findings / Image Gallery

Roof area very well detailed and in goodcondition

Some exellent workmanship on display here

Valley and ridge cap flashings in good order Leak dripping from this junction, repair needed

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 34: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Inspection Summary

The inspection summary is not intended to replace details shown throughout the report. Please read the entiredocument as there may be issues throughout the report that the client may consider significant which may nothave been included in the inspection summary above.

InternalThe interior of this home is in exellent condition, very little wear and tear noted. It could be described as innear new condition.No unusual moisture readings were taken from any of the perceived risk or target areas.The remodelling and renovation that has taken place here has been completed to a very high standard.

ExternalThe roof areas are in good order, no concerns.Foundations are in exellent condition, solid and sound.Timer weatherboards and paint are generally in good condition, some bubbling of paint noted and someearly stage paint flaking noted. General rule of thumb is that exposed timber should be sealed. Followingthis rule, some touch up painting from time to time will certainly defer having to repaint. Exterior coatinghere is regarded as well above average.Joinery installations and detailing is very good, no concerns.

OverviewA very good example of what can be achieved with the right vision and energy.This home was a pleasure to inspect.

Visual Structural AssessmentGenerally good

Todd Russell

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 35: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Certificate

Certificate Of InspectionIn Accordance with NZS 4306:2005

ClientSite AddressInspectorCompanyQualificationDate of Inspection

Mr SmithSampleTodd RussellTotal Home Inspection Services Ltd Qualified Builder / Experienced Inspector 30 April 2014

The following areas of the property have been inspected:Site InspectedSubfloor InspectedExterior InspectedRoof Exterior InspectedRoof Space InspectedInterior InspectedServices Partially inspectedAccessory Units, etc Briefed over

Any limitations to the coverage of the inspection are detailed in the written report.

CertificationI hereby certify that I have carried out the inspection of the property site at the above address inaccordance with NZS 4306:2005 Residential Property Inspection - and I am competent toundertake this inspection.

Inspector: Todd RussellDate: 30/04/2014

An inspection carried out in accordance with NZS 4306:2005 is not a statement that a propertycomplies with requirements of any Act, regulation or bylaw, nor is the report a warranty against anyproblems developing after the date of the property report. Refer to NZS 4306:2005 for full details.

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 36: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Common Features

Common featuresThese are some common features that can be risk areas on monolithic/textured homes:1. Parapets and flat roofs2. Roof to wall junctions3. Pergola fixings4. Handrail fixings5. Lack of flashings to windows and penetrations6. Decks over living areas7. Balustrade to deck or balustrade to wall junctions8. Clearances at bottom of claddings9. Level of ground outside is above interior floor level

Figure 1If your house has some or all of these features it does not necessarily mean that you have aleaky home. This is why you need a reputable inspection company such as Total HomeInspection Services Ltd to survey the home you are purchasing or the home you are selling.In our experience, if these areas are detailed, sealed and flashed correctly, their risk can besignificantly minimized .Regular checking and maintenance of these areas is highly recommended to ensure theyremain issue free.

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 37: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Monotlithic / Textured HomesMaintaining your home is very important, and for monolithic homes this is extremelyimportant. As with any type of home, if maintenance is ignored issues will arise.

Outlined above and below are areas that need to be regularly maintained. The two largeareas that should be scheduled regularly are:

1. A regular inspection of the exterior looking for hairline cracks etc. followed by a regularapplication of the correct paint system to ensure an impervious coating. Exterior paintsystems intervals can vary from 6-8 year intervals. Check with manufacturer or professional.

2. Any deck over living that has an emulsion type membrane requires a regular application ofthat emulsion. Varies 4-8year intervals. Check with manufacturer or professional.• Clearing all gutters, downpipes and balcony drains of blockages so that rainwater can drainaway quickly.

• Inspecting roofs for areas of corroded roofing material that could allow water to enter.

• Keeping the dirt level in gardens below the bottom edges of cladding to prevent moisturesoaking up inside the cladding.

• Regular checking/sealing of all penetrations through exterior cladding.

• Regular checking/sealing around windows, flashings, exterior doors etc.

To wash, use a soft brush and low-pressure hose, concentrating on areas rain doesn't reach,like walls sheltered by eaves. For sea spray, moss and lichen, you might have to use specificcleaning products or a one part bleach to four parts water solution and soft brush.

Hose off residue with plenty of water and avoid using ladders around wet areas as much aspossible. Check with the manufacturer of your cladding and your local hardware store if youare unsure.

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT

Page 38: Executed by: THISNZ Total Home Inspection Services Ltd ...thisnz.co.nz/wp-content/uploads/2014/09/sample.pdf · Council Property File LIM REPORT ”Land information Memorandum”

Feedback

Thank you!Mr Smith

We, at T.H.I.S Ltd, trust you have found this Inspection report both helpful and informative.Our goal is to ensure that your dealings with T.H.I.S Ltd have exceeded your expectations.We are dedicated to supplying you, our client, with friendly, informative and timely service.

If we have met or exceeded your expectations we would like to hear about it, if for anyreason we have failed to meet your expectations, we would like to hear about it.This client feedback will help us to continually improve our service.Please note that this inspection has been a visual inspection only as stated in our Terms &Conditions. Whilst I have taken every care to comment on all aspects of the house, I mayhave had to make some assumptions for areas of the property that cannot be sighted. Thiswill have been stated in the report.

SERVICESPrepurchase Home InspectionsRoof, Cladding, Foundations, Interior, Moisture scanning to exterior walls.Electrical, Plumbing, Drainage.Energy Efficiency ReportsExterior walls (Insulation), Heating systems (space and water), Glazing, Under floor& concrete slabs.Safe and Sanitary InspectionsThermal Imaging inspectionsExterior walls, Leak detection, Electrical wiring hotpoints, Risk Area Investigation. Monolithic(textured) Cladding risk assessment. (Ideal for vendor)Annual Monolithic Cladding Insp.Window & door head flashings, cracking and subsidence, Surface & substrate deterioration.Full Ingressive SurveyRemoval of claddings interior or exterior for in depth substrate or services assessment.

30 Apr 2014 | Copyright 2013 THINZ Total Home Inspection Services Ltd

SAMPLE

REPORT