evgc6a-a · discover ev traction dry cell - constant current iui. an indefinite float phase may be...

2
*CRANKING AMPS: Cranking Amps data is provided as a reference only. Specific application sizing and life factors must be considered when using deep cycle product in a starting application. **CAUTION: Extra considerations must be given to depths of discharge, operating voltages and currents when designing systems for use at maximum temperatures. EV Series Features & Benefits Electrical Specifications Maintenance Free Clean & Green ® choice of Original Equipment Manufacturers. Traction heavy duty grid design (PbCaSn) gives consistent active material adhesion and corrosion resistance. High impact reinforced copolymer and polypropylene cases with flat top designs. A recognized gas recombination efficiency of greater than 99.9%. Multiple terminal, configuration options and carrying handles available with most models. Classified as a non-spillable battery and is not restricted for transportation by: Air (IATA/ICAO provision 67) Surface (DOT-CFR-HMR49) Water (per IMDG amendment 27). Compatible with sensitive electronic equipment. Comprehensive design to conserve resources, improve safety and reduce waste. 98% recyclable. Discover® EV Series Industrial Batteries provide superior high integrity and reliability for commercial, industrial and private applications. The maintenance-free, thick plate construction, designed for tough applications and repeated deep discharging makes the EV Series the definitive choice for robust Traction applications including Home Medical Equipment (HME), Electric Vehicle, Automated Guided Vehicles (AGV), Aerial Lifts, Floor Cleaning Equipment, Robotics, Materials Handling, Renewable Energy and Marine / RV applications. EV Traction Dry Cell Industrial Battery Block Updated April 30 2014 ® ® Mechanical Specifications Electrical Specifications Certifications and Standards Contact Us Discover Energy Corp. Suite 880-999 West Broadway Vancouver BC V5Z 1K5 Canada Tel: 604.730.2877 Email: [email protected] www.discover-energy.com Industry Reference Length [A] Width [B] Height [C] Total Height [D] Weight Terminal (Opt’l) Terminal Torque NM Cells Electrolyte 1.2875 S.G. AGM Volts 80% DOD Voltage Cutoff RINT Short Circuit (68˚F / 20˚C) Self Discharge Cranking Amps* Standard Charge 50˚F / -10˚C to 122˚F / 50˚C Standard Discharge -4˚F / -20˚C to 122˚F / 50˚C Maximum Discharge** -40˚F / -40˚C to 140˚F / 60˚C Amp Hours (AH) Minutes of Discharge 100HR 20HR 10HR 5HR 3HR 1HR @25A @56A @75A @85A @100A Max Charge / Discharge Currents Peak (5 seconds) Peak (10 seconds) Max Continuous Recommended Max Continuous Charge 1C10Hr 0.75C10Hr 0.5C10Hr 0.3C10Hr Discharge 2C10Hr 1.5C10Hr 1C10Hr 0.5C10Hr Designed in accordance with and published in compliance with applicable BCI, IEC and BS EN standards, including: IEC60896-21/22 BS EN 60254-1:2005 AS/NZS 4029.2.2000 BS EN 60254- 1:2005 (MOD). Discover ® and its facilities and products are certified to multiple standards: ISO, UL, QS, and TUV standards ETTS Germany Euro Bat classification for Environmental Stewardship Standards. 16 M8 4 Optional Terminal (M8) Positive (+) Negative (-) 5/16” 17 17 2 20 2 20 1:9 1:9 5/16” 19.5 17.9 40 40 25 25 25 25 Terrminal (AM) GC6 10.3 in 262 mm 7.09 in 180 mm 10.0 in 254 mm 10.8 in 274 mm 66 lbs 30 kgs AM (M8) 7.0-8.5 (9.5-10.5) 3 cell 6 V 5.7 V 1.80 mOhms 3000A <3% of capacity month @ 68˚F / 20˚C 890 @ 32˚F / 0˚C 715 @ 0˚F / -18˚C 240 220 200 190 170 130 475 185 175 107 88 EVGC6A-A B A D C NEG POS

Upload: others

Post on 03-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EVGC6A-A · Discover EV Traction Dry Cell - Constant Current IUI. An indefinite float phase may be added at 2.27vpc. V. 2 = 2.60vpc U = 2.465 +/- .015vpc. Initial Charging Current

*CRANKING AMPS: Cranking Amps data is provided as a reference only. Specific application sizing and life factors must be considered when using deep cycle product in a starting application.

**CAUTION: Extra considerations must be given to depths of discharge, operating voltages and currents when designing systems for use at maximum temperatures.

EV Series Features & Benefits

Electrical Specifications

• Maintenance Free Clean & Green® choice of Original Equipment Manufacturers.

• Traction heavy duty grid design (PbCaSn) gives consistent active material adhesion and corrosion resistance.

• High impact reinforced copolymer and polypropylene cases with flat top designs.

• A recognized gas recombination efficiency of greater than 99.9%.

• Multiple terminal, configuration options and carrying handles available with most models.

• Classified as a non-spillable battery and is not restricted for transportation by: • Air (IATA/ICAO provision 67) • Surface (DOT-CFR-HMR49) • Water (per IMDG amendment 27).

• Compatible with sensitive electronic equipment.

• Comprehensive design to conserve resources, improve safety and reduce waste. 98% recyclable.

Discover® EV Series Industrial Batteries provide superior high integrity and reliability for commercial, industrial and private applications. The maintenance-free, thick plate construction, designed for tough applications and repeated deep discharging makes the EV Series the definitive choice for robust Traction applications including Home Medical Equipment (HME), Electric Vehicle, Automated Guided Vehicles (AGV), Aerial Lifts, Floor Cleaning Equipment, Robotics, Materials Handling, Renewable Energy and Marine / RV applications.

EV Traction Dry Cell Industrial Battery Block

Updated April 30 2014

®

®

Mechanical Specifications Electrical Specifications

Certifications and Standards

Contact UsDiscover Energy Corp. Suite 880-999 West Broadway Vancouver BC V5Z 1K5 CanadaTel: 604.730.2877 Email: [email protected]

Industry Reference

Length [A]

Width [B]

Height [C]

Total Height [D]

Weight

Terminal (Opt’l)

Terminal Torque NM

Cells

Electrolyte 1.2875 S.G. AGM

Volts

80% DOD Voltage Cutoff

RINT

Short Circuit (68˚F / 20˚C)

Self Discharge

Cranking Amps*

Standard Charge 50˚F / -10˚C to 122˚F / 50˚C

Standard Discharge -4˚F / -20˚C to 122˚F / 50˚C

Maximum Discharge** -40˚F / -40˚C to 140˚F / 60˚C

Amp Hours (AH) Minutes of Discharge

100HR 20HR 10HR 5HR 3HR 1HR @25A @56A @75A @85A @100A

Max Charge / Discharge Currents Peak (5 seconds) Peak (10 seconds) Max Continuous Recommended Max Continuous

Charge 1C10Hr 0.75C10Hr 0.5C10Hr 0.3C10Hr

Discharge 2C10Hr 1.5C10Hr 1C10Hr 0.5C10Hr

Designed in accordance with and published in compliance with applicable BCI, IEC and BS EN standards, including: • IEC60896-21/22 • BS EN 60254-1:2005 • AS/NZS 4029.2.2000 BS EN 60254- 1:2005 (MOD).

Discover® and its facilities and products are certified to multiple standards: • ISO, UL, QS, and TUV standards • ETTS Germany • Euro Bat classification for Environmental Stewardship Standards.

NEG

POS

NEG

POS

16

M8

4

Optional Terminal (M8)

Positive (+) Negative (-)

5/16”

17 17 2 202 20

1:9

1:9 5/16”19.5 17.9

40 40

252525 25 Terrminal (AM)

GC6

10.3 in 262 mm

7.09 in 180 mm

10.0 in 254 mm

10.8 in 274 mm

66 lbs 30 kgs

AM (M8)

7.0-8.5 (9.5-10.5)

3 cell

6 V

5.7 V

1.80 mOhms

3000A

<3% of capacity month @ 68˚F / 20˚C

890 @ 32˚F / 0˚C 715 @ 0˚F / -18˚C

240 220 200 190 170 130 475 185 175 107 88

EVGC6A-A

BA

DC

NEG

POS

Page 2: EVGC6A-A · Discover EV Traction Dry Cell - Constant Current IUI. An indefinite float phase may be added at 2.27vpc. V. 2 = 2.60vpc U = 2.465 +/- .015vpc. Initial Charging Current

Graphs

®

®

www.discover-energy.com

Charging is not necessary unless 100% of capacity is required.

Charging before use is necessary to recover full capacity.

Charge may fail to restore full capacity. Do not let battery reach this state.

1 2 4 6 8 10 12 14 16 18 20

100

80

60

40

40˚C / 104˚F 30˚C / 86˚F 20˚C / 68˚F

5˚C / 41˚F

Capa

city (

%)

Self - Discharge Characteristics

Storage Time (months)

Discover Energy Corp. attempts to ensure the correctness of the product description and data contained herein. We reserve the right to change designs, specifications and pricing at any time without notice or obligation. It is the responsibility of the reader of this information to verify any and all information presented herein.

Temperature Effects on Capacity

Temperature (˚C)

Capa

city (

%)

0.1 ˚C0.2 ˚C

1.0 ˚C

2.0 ˚C

6.75

6.5

6.25

6

5.75

5.5

Relationship of OCV and State of Charge (20˚C)Relationship of OCV and State of Charge (20˚C)

Relative State of Charge (%)

Batte

ry V

oltag

e (V

)

Capa

city (

%)

80% D.O.D 50% D.O.D 20% D.O.D

Number of Cycles

Cycle Service Life in Relation to Depth of Discharge

Volts Per Cell (VPC)

Max 14 Hrs Max 5 Hrs Max 4 HrsMaximum Charge Time Must be Limited to 24 Hours

Absorption Balance/TerminationBulk

Discover EV Traction Dry Cell - Constant Current IUIAn indefinite float phase may be added at 2.27vpc

V2 = 2.60vpc

U = 2.465 +/- .015vpc108% - 112% recharge

Initia

l Cha

rging

Cur

rent

I = X

C20

Rat

ing

Discover EV Traction Dry Cell - Voltage Regulated IUU

Bulk Absorption Float

Initia

l Cha

rging

Cur

rent

I = X

C20

Rat

ing

Volts Per Cell (VPC)

U = 2.45 +/- .015vpc

U2 = 2.27vpc

Max 14 Hrs Max 8 Hrs No Time Limit

Relationship Between ChargingVoltage and Temperature

Cycle Use

Standby Use

Ambient Temperature (˚C)

V/ 8

V

V/ 6

V

V/ 4

V

V/ C

ell

V/ 1

2V

Bulk Absorption Balance/Termination

Maximum Charge Time Must be Limited to 24 Hours

Discover EV Traction Dry Cell - Constant Current IUI with Pulse Termination

Initia

l Cha

rging

Cur

rent

I = X

C20

Rat

ing

Volts Per Cell (VPC)

U = 2.435 +/- .015vpc

I1 = .25 x C20 Capacity +/- .05 x C20 (minimum I1 =0.10 x C20)

Temperature Coef. +/- .005vpc/C, 0.003vpc /F from 25˚C (77˚F)

Max 18 Hrs Max 5 Hrs Max 4 Hrs

V2 = 2.60vpc

V3 = 2.35vpcI2 = .01 x C20 Capacity

NOTE: This algorithm uses a pulse termination criterion. As a safety precaution during the Finish phase, if the average cell voltage, or volts per cell (vpc), exceeds V2 and the charger output has been on for more than 30 seconds, the output is shut off until the vpc falls to V3. The finish phase then resumes and this “pulsing” continues until the target overcharge (108% - 112%) is reached.

Contact Discover Energy Corp. for OEM specific charging algorithms. [email protected]

I1 = .25 x C20 Capacity +/- .05 x C20 (minimum I1 =0.10 x C20)

Temperature Coef. +/- .005vpc/C, .003vpc /F from 25˚C (77˚F) Max 16% I1

I1 = .25 x C20 Capacity +/- .05 x C20 (minimum I1 =0.10 x C20)

Temperature Coef. +/- .005vpc/C, .003vpc /F from 25˚C (77˚F)

Dv/Dt = 2.5mV/Cell/Hror 108% - 112% recharge