FOODSERVICE EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
TABLE OF CONTENTS
Introduction 2Inspection 2
Tools and Supplies Required 2General Precautions 2Selecting A Location 4Dimensions 4Specifications 4Installation 5
Grounding Instructions 5Placing the System In Position 5Parts Identification 5System Pneumatic Diagram 5Connections 5
Preventative Maintenance 6Six-(6) Month Maintenance Procedure - Service Kit #1 612-Month Maintenance Procedure - Service Kit #2 818-Month Maintenance Procedure - Service Kit #1 924-Month Maintenance Procedure - Service Kit #3 9
Troubleshooting 10Troubleshooting Procedure 1 - Test Air Dryer Function 12Troubleshooting Procedure 2 - Leaks at Quick-Connect Fittings 12
Gas Flow System Schematic 13Coalescing Filter Part Identification 13WACO2 Connections 13Pneumatic Diagram 14Electrical Diagram 14Replacement Parts 15
Cabinet 15Compressor 16Aftercooler and Filters 17Miscellaneous Replacement Parts 18 McDonald's Compressor Filter Kits 18
Limited Warranty 19Service Log 23
EverDri Compressed Air System
EVERPURE® EVERDRI™ HIGH CAPACITY COMPRESSED AIR SYSTEM OWNER'S MANUAL
2 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
INTRODUCTIONThis Everpure EverDri High Capacity Compressed Air System by Pentair is intended to be the primary driver for actuating the following types of equipment in a restaurant, which are currently being driven by CO2:
• Bag-in-Box (BIB) Syrup Pumps for Soft Drinks• Mechanics of the Automated Beverage System (ABS)• Product Pumps in the Blended Ice Machine (BIM)• Bulk Ketchup Pumps• Next Generation Iced Tea Brewers• Any additional equipment powered by CO2
The EverDri High Capacity Compressed Air System is designed to output a constant air pressure for operating restaurant equipment. During normal operation, the compressor will automatically cycle on and off as compressed air is needed. The compressor automatically turns on at the "cut-in" pressure, typically near 95 psig (6.5 bar). When the air pressure in the compressor tank reaches ~ 125 psig (8.6 bar), the compressor has reached "cut-out" pressure and will automatically turn off. Elevated noise levels are normal when the compressor switches off as pressure is relieved within the enclosure. The compressor system also has a cooling fan mounted to the enclosure that is designed to run continuously.
INSPECTIONInspect the box and skid for damage or tampering due to transportation. If damaged, immediately contact the transportation company.
NOTE: Do not cut the tape on the top of the box. This may damage the Compressor cabinet.
Cut and remove two band straps. Lift cardboard box straight up and remove protective cardboard on top and plastic bag. Check for any loose nuts or bolts inside the cabinet and on the legs. Tighten if necessary. Certify that all damaged parts are replaced and that all mechanical and electrical problems are solved before operating the equipment.
Before installing the Everpure EverDri Compressed Air System, inspect the parts. Use the table and illustration provided to verify the parts and quantities provided. If any parts are missing, contact Customer Service at 800.942.1153 (US only)/630.307.3000 or by email at [email protected].
Installation and
Operation Guide
1
2
Parts Qty
1. Cabinet with Compressor System 1
2. Installation and Operation Guide 1
Tools and Supplies Required• Safety Glasses• Cut-Resistant Gloves• Hearing Protection• Pliers• Carpenters Level• Large Flat Blade Screwdriver• Wrench (for tubing connection)• Utility Knife or Tube Cutter (for plastic tubing)• Oetiker Clamps• Barbed Tubing Connectors• Plumber's Tape• Approved Tubing• Compressed Air Tubing rated to 150 psig (10.3 bar)
NOTE: Not all tools listed may be necessary for installation. Read installation procedures before starting to determine required tools.
WARNING: Before installing the system, make certain your installation complies with the following operating specifications. Failure to do so may reduce the effectiveness of the system and will void the warranty.
GENERAL PRECAUTIONSWARNING: To avoid unpredictable system behavior that can
cause personal injury and property damage:• Disconnect electrical supply before
installation or servicing.• Release all pressure in the tank before
performing any maintenance.• Disconnect air supply and depressurize all
air lines connected to this product before installation or servicing.
3 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
• Operate within the specified pressure, temperature, and other conditions listed in these instructions.
• Do not operate below 41°F (5°C).• Service according to procedures listed in
these instructions.• Installation, service, and upgrades of
these products must be performed by knowledgeable, authorized personnel.
• After installation, servicing, or upgrades, air and electrical supplies should be connected and the product tested for proper function and leakage. If audible leakage is present or the product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered. If necessary, contact your local representative for replacement labels.
WARNING: This equipment, if used improperly, can cause physical and material damage. To avoid this, follow the instructions below:• This equipment must not be used by people
with physical, sensory, or mental handicaps, or without knowledge of use and training.
• People without the proper experience or knowledge may use this equipment only if supervised and instructed by someone who is responsible for his or her safety.
• This equipment must not be used by children under any circumstances.
• Do not service the equipment when tired, under the influence of medication, alcohol or drugs. Lack of attention during operation may result in serious personal injury.
• The equipment may cause mechanical or electrical interference on nearby sensitive equipment.
• The equipment must be installed and operated in places that are ventilated and protected against humidity and presence of water.
• While in use, the equipment has electrical components and hot moving parts.
• Do not alter the settings of the safety valve, pressure switch or other factory settings. They are preset at the factory. If some adjustment is necessary on the product, use the service of the nearest authorized Pentair Everpure Dealer.
• Never exceed the maximum pressure indicated on the compressor’s identification name plate/sticker.
• Verify condition of the product’s safety systems. In case of abnormalities, stop using the product and contact authorized Pentair Everpure Dealer for repairs.
• Never perform repairs or welding services on the tank, because they can affect its resistance or mask more serious problems. If there is any leak, crack or corrosive wear, immediately stop using the equipment and find an authorized Pentair Everpure Dealer.
• Use only plumber's tape without adhesive backing to seal joints. Do not use pipe compound (“pipe dope”), sticks, or similar compounds with this unit. They contain petroleum derivatives which can cause crazing and cracking of the plastic in the filter housing.
• Never operate the compressor without filters in place. The compressed air must be treated with filters suitable for the application and use.
• Never direct a high pressure air jet directly at another person or at the skin.
• Do not allow the compressor to come in contact with any flammable substances.
• Never clean the compressor with solvents or any other flammable products. Use a neutral detergent.
• In the presence of any change in noise or operation of the compressor, immediately stop using the equipment and contact the nearest authorized Pentair Everpure Dealer.
• The compressor automatically resumes operation after the power supply is interrupted and then reestablished. Make sure the equipment is not connected to the power supply before proceeding with any service or maintenance, even during a short power interruption.
• Make sure that the product’s maintenance and operation are performed by a properly trained and qualified professional.
WARNING: To reduce the risk of electrical shock, the following is recommended:• Install a residual current circuit breaker.
Consult an electrician to select and install this safety device.
• Do not use the equipment while you are barefoot, in wet or very humid places.
• Before cleaning or performing maintenance, disconnect the equipment from the electrical power supply.
• Do not make splices in the power cord. If required, ask for a power cord replacement through the nearest authorized Pentair Everpure Dealer. Costs of power cable replacement are the sole responsibility of the customer.
• Power outlet must be compatible with the equipment’s plug. To reduce the risk of shock, do not change the plug’s characteristics and do not use adapters. If required, replace the outlet with a suitable model.
• Do not use your electrical equipment in explosive atmospheres (gas, liquid or dust). The motor can generate sparks that may cause explosion.
• Make sure the breaker switch is in the OFF position before connecting the equipment to the power supply.
• Do not puncture power cords, gas or water pipes. Contact with water or electric wires may cause electric shock.
4 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
WARNING: To reduce the probability of an accident because of contact with rotating parts:• Do not operate the product, under any
circumstances, when the safety guards of the rotating parts are not installed.
• Do not wear long clothing, chains or jewelry that may come into contact with the moving parts of the product during service. If you have long hair, tie it back.
• Remove all adjustment tools before turning your equipment on. A key or tool stuck in rotating parts of the equipment may cause serious injuries.
NOTE: The user of this product must maintain the air tank's record book provided by the manufacturer until the equipment is no longer in service. The end user must follow the standards required locally regarding installation, maintenance, and operation of the compressed air tank.
NOTE: The hydrostatic test carried out during the product manufacturing does not replace the initial inspection, which must be carried out at the location where the product is installed, duly monitored by a certified professional, following local codes.
NOTE: All local codes and safety procedures must be followed.
SELECTING A LOCATION1. Give consideration to the weight of the unit when
operating. Operating weight of the Everpure EverDri Compressed Air System is approximately:• 195 lbs (88.5 kgs)
2. The location should allow for:• Six (6) inches of clearance on all sides for connections
and air flow.• Adequate space for the outlet air line connection on
the right side.• Be near a drain for removing coalesced water.• Use of the eight (8) foot power cord using standard
grounded wall plug rated for 15 amps minimum.3. Do not install the Everpure EverDri Compressed Air
System in an area with a high amount of dust, particulates or moisture. If this is unavoidable, review the maintenance cycles and decrease the time between filter changes.
4. The floor should be flat and level.
5. Install indoors.
DIMENSIONS6" (15 cm) Clearance Required
6" (15 cm) Clearance Required
24" (60 cm)
36" (91 cm)
24" (60 cm) 20.9"
(53 cm)
6" (15 cm)
Figure 1
SPECIFICATIONS
Weight: Approximately 195 lbs (88.5 kg)Electrical Connection: 115 VAC, single phase, 60 Hz; GFCI
or RCD protected 15 amp circuitOperating Environment Temperature:
41 - 105°F (5 - 40.5°C) continuous
Tank Capacity: 8 gallons (30 L)Maximum Tank Pressure Requirements:
150 psig (10.3 bar) maximum
Outlet Air Pressure: 90 - 95 psig (6.2 - 6.5 bar) regulated
Outlet Shut-off Valve: 1/4" FNPTPressure Relief Valves: Rated to 150 psig (10.3 bar)Air Quality Output: ISO 8573-1 Class 1 for particulates
ISO 8573-1 Class 3 for moisture content
ISO 8573-1 Class 0 for oil content, oil free
5 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
INSTALLATIONNOTE: Please read all instructions, specifications, and
precautions before installing and using your Everpure EverDri Compressed Air System.
Grounding InstructionsThis system must be grounded. This system is equipped with a power cord having an appliance-grounding conductor and a grounding plug. The plug must be inserted into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
WARNING: Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit in the outlet, have a proper outlet installed by a qualified technician.
Placing the System In PositionWARNING: The system weighs about 195 lbs ( 88.5 kg). Use
proper lifting equipment to move it and only place in a location that can support this weight to prevent injury and death.
1. Leave the protective cardboard on right side of system to protect outlet valve during movement to final installation site. Remove the cardboard before startup.
2. Take power cord out from underneath and behind system. Tape it to the top of the cabinet to protect it during installation.
3. Do not turn on the equipment if it is not in perfect working condition.
4. The installation location must have electrical power close enough to use the supplied electrical cord and a drain for the coalesced water that exits on the bottom right side.
5. The floor should be flat and level. Screw the levelers in/out to adjust the length of each leg. When finished, all legs should be in contact with the floor and the system cabinet should be level.
Parts Identification
Compressor Intake Filter
Heat Exchanger
Pressure Regulator
Compressed Air Outlet
Coalescing Filter
2-Cylinder Compressor
Membrane Air Dryer
Water Drain
Tank Drain
Levelers (4)Storage
Tank
Hour Meter
Air Intake Filter
Air Intake Fan
Circuit Breaker
Air Vent Filters
Figure 2
System Pneumatic DiagramTo provide clean compressed air, the Everpure EverDri High Capacity Compressed Air System uses an oil-less compressor, heat exchanger, coalescing filter and a membrane air dryer. The clean, compressed air is stored in a tank until used. A complete pneumatic diagram is provided at the back of this manual.
ConnectionsAn electrical diagram is provided at the back of this manual. Before making the electrical and tubing connections check the following:
• The shipping cardboard has been removed.• There is a minimum of six (6) inches (15 cm) clearance
on all sides. • The cabinet is level.
NOTE: If the cabinet needs to be opened for start up, use a coin or flat screwdriver to turn the lock screws on the door to the left (counterclockwise).
To complete the installation:
1. Connect the high-pressure compressor air line from the application crossover valve to the 1/4-inch female NPT fitting on the cabinet ball valve for high pressure air (Figure 3). Use a small amount of plumber's tape on the threads.
6 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Application
Air Compressor Inlet
Backup CO2 Inlet
BackupBIB Pressure
Normal Operation
Figure 3 Crossover Valve
2. CLOSE the ball valve on the cabinet lower right side.
3. The coalescer drain tube should be extended to reach a nearby drain. The tubing must have a constant downward slope for proper draining.
4. The Everpure EverDri High Capacity Compressed Air System is ready to be started.
WARNING: Use extreme caution when the cabinet door is open. The compressor may start unexpectedly. Contact with moving parts may cause personal injury or damage to the equipment.
NOTE: The operator is expected to keep and maintain a log sheet. Use a stopwatch to record the date and the time it takes to pressurize the system. A sample log sheet is available on the last page of this manual. Have a stopwatch ready to record the compressor run time.
5. Plug the electrical cord into the wall receptacle. The compressor will start. If the compressor does not start, check that the circuit breaker is in the up (on) position.
6. Record on the log sheet the amount of time it takes to pressurize the system from 0 psig to 125 psig (8.6 bar). The compressor will turn off.
NOTE: If the tank was pressurized prior to this startup, then remove power. The valve at the bottom of the tank should be opened. When tank pressure is zero (0), close the valve, plug the power cord back in and perform the test.
7. Record the date and the pump up time on the preventative maintenance log sheet that is stored on the inside of the door.
8. To complete the startup, check that the application crossover valves are in the correct positions. The application equipment should be ready to operate.
9. Slowly open the ball valve on the Everpure EverDri Compressed Air System to provide pressure to the applications. The valve is located on the cabinet's right side at the bottom rear of the panel.
10. To ensure efficient operation, be sure all restaurant compressed air tubing, fittings and equipment are leak free. Leaks will cause excessive compressor runtime and early wear.
PREVENTATIVE MAINTENANCEThe Everpure EverDri Compressed Air System requires periodic maintenance. The preventative maintenance program that follows describes the action items that must be performed every six (6) months. A log sheet is included at the back of this manual. Use the log sheet to record the results of each preventative maintenance event. Keep the log sheet in the holder mounted inside the door of the cabinet.
The maintenance procedures are based on a six-(6) month schedule. Refer to the service schedule table at the back of this document for dates and kit numbers. Order the kit required to receive all the replacement parts needed for the procedures.
CAUTION: Compressor may start unexpectedly if power is on. Be certain to turn off or remove power.
CAUTION: Compressor motor and head may be hot.CAUTION: Air tank contains air under pressure. CAUTION: Do not wear long clothing, chains or jewelry that
may come into contact with the moving parts of the product during service. If you have long hair, tie it back.
CAUTION: While in use, the equipment has electrical components and hot moving parts.
When diagnosing the EverDri Compressed Air System, the time it takes to "pump-up" the air storage tank may be measured. This time is expected to be two (2) minutes, 50 seconds when starting at 0 psig and turning off at 125 psig (8.6 bar)
To measure compressor pump-up time, follow this procedure:
1. Unplug compressor.
2. Close outlet ball valve.
3. Drain all air from tank using valve on bottom of tank. Close the valve when done.
4. Plug in compressor and measure the time from the startup to automatic shutoff.
Six-(6) Month Maintenance Procedure - Service Kit #1
Tools and Supplies• Safety Glasses• Hearing Protection• Flat Blade Screwdriver• Plumber's Tape• Service Kit #1:
One (1) New Cabinet Intake Filter Two (2) Compressor Air Intake Filters
1. Switch the compressed air switchover valve to the backup CO2 inlet. The backup system will power application equipment during this procedure. If a backup air pressure system is not available, the application equipment will not operate during this procedure.
7 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Application
Air Compressor Inlet
Backup CO2 Inlet
Normal Operation
Figure 4
2. Unplug the power cord.
3. CLOSE the compressed air outlet valve (Figure 5) so the blade is perpendicular to the valve body. OPEN cabinet door. Use a large flat blade screwdriver to unscrew the two (2) door lock screws.
Open
Closed
Figure 5
4. Replace the fan prefilter.• OPEN the left side cabinet vent cover by pulling out on
the top edge, Figure 6. The cover will swing down.• Remove the air prefilter and discard.• Place the new prefilter into the opening. The soft side
of the filter should be facing out, away from the cabinet.
• CLOSE the vent cover. It will snap closed.
Pull out on top edge
Figure 6
5. Replace the two (2) compressor intake filters.• Unscrew the filters on the left side by hand, (Figure 7)
(counterclockwise). A wrench may be used if needed.• Discard the old filters.• Remove any loose plumber's tape from fittings.• The new filters have "IN" and "OUT" moulded into the
ends. The fitting on the end marked "OUT" screws into the compressor head. Firmly hand tighten each one by turning clockwise. Do not tighten with wrench.
RemoveIN
Compressor Air Intake (2)
OutIn
Air Tank Valve
Figure 7
6. Check for water in air tank. • OPEN the valve located at the bottom of the air tank.
The compressed air will escape through the valve.• Observe the air. It must not contain any moisture.• CLOSE the valve located at the bottom of the air tank
after all air has been vented.CAUTION: If moisture is present, refer to the
Troubleshooting section in this manual. Do not vent air toward any body part.
7. Close and lock the cabinet door.
NOTE: Have a stopwatch ready to record the compressor runtime.
8. Restart the EverDri Compressed Air System.
NOTE: Measure and record the date, the hour meter time (upper left side) and the time it takes to pump up the system. If the pump up time is greater than two (2) minutes, 50 seconds, see Troubleshooting.
8 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
• Apply power. Allow the system to turn off using the automatic shut-off switch. Record the pump-up time.
• OPEN the compressed air outlet valve.• Position the crossover valve to use the EverDri
compressed air for the applications (Figure 8).• System is now operational.
Application
Air Compressor Inlet
Backup CO2 Inlet
Normal Operation
Figure 8
12-Month Maintenance Procedure - Service Kit #2
Tools and Supplies• Safety Glasses• Hearing Protection• Flat Blade Screwdriver• Plumber's Tape• Service Kit #2:
One (1) Cabinet Air Intake Filters Two (2) Cabinet Air Vent Filters Two (2) Compressor Air Intake Filters Coalescer Filter Element
The 12-Month Maintenance Procedure starts with performing the Six-(6) Month Maintenance Procedure. This is then followed by changing the coalescer filter element and the filter media for the cabinet air exhaust.
1. Refer to the "Six-(6) Month Maintenance Procedure - Service Kit #1". Perform steps 1 through 6. Do not restart the compressor.
2. Change the coalescing filter element. • Remove the bowl by turning it to the left
(counterclockwise). Lay it down with the drain tube still attached (Figure 9).
NOTE: There may be a small amount of water in the bowl. This is normal.
• Grasp the filter element and unscrew it to the left (counterclockwise). Discard the old filter.
NOTE: The threads are a fine pitch and will unscrew slowly.• Locate the plastic bag with the new filter element.
CAUTION: Do not handle the filter element with bare hands. Skin oils may damage the element. Use the plastic bag to handle the filter element.
• Inspect the threaded end of the filter element for the presence of the rubber gasket. Be certain that the gasket is properly located.
CAUTION: Do not install the filter element without the rubber gasket. Performance of the coalescing filter will be affected.
• Screw the coalescer filter element into the body by turning it to the right (clockwise). Tighten finger tight. Do not use tools. Throw away bag.
• Inspect the bowl's top edge for correct positioning of the sealing o-ring.
• Install the bowl by lining up the tabs with slots in the body and pushing up. Rotate the bowl to the right (clockwise) to engage and lock the bowl in place.
• The drain hose should be connected and have a straight downhill path to a drain.
• Ensure the coalescer drain tube is securely fastened.
Bowl
Coalescer Filter
Element
Gasket
O-Ring
Drain Tube
Clamp
Figure 9
3. Replace the cabinet air vent filters. • OPEN the two (2) cabinet vent covers on the right side
of the cabinet by pulling out on the top edge. The cover will swing down (Figure 10).
• Remove the filter media and discard.• Place the new filters into the openings. The soft side of
the filter should be facing out, away from the cabinet.• CLOSE the vent covers.
Air Vent Exhaust Filters
Figure 10
9 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
4. Close and lock cabinet door.
NOTE: Have a stopwatch ready to record the compressor runtime in the log sheet.
5. Restart the EverDri Compressed Air System.
NOTE: Measure and record the date, the hour meter time (upper left side) and the time it takes to pump up the system. If the pump up time is greater than two (2) minutes, 50 seconds, see Troubleshooting.
• Apply power. Allow the system to turn off using the shut-off switch. Record pump-up time.
• OPEN the compressed air outlet valve. • Position the crossover valve to use the EverDri
compressed air for the applications (Figure 11).• System is now operational.
Application
Air Compressor Inlet
Backup CO2 Inlet
Normal Operation
Figure 11
18-Month Maintenance Procedure - Service Kit #1The 18-Month Maintenance Procedure is the same as the Six-(6) Month Maintenance Procedure. Refer to "Six-(6) Month Maintenance Procedure - Service Kit #1".
24-Month Maintenance Procedure - Service Kit #3
Tools and Supplies• Safety Glasses• Hearing Protection• Flat Blade Screwdriver• Service Kit #3:
One (1) Cabinet Air Intake Filter Two (2) Cabinet Air Vent Filters Two (2) Compressor Air Intake Filters Coalescer Filter Element Membrane Air Dryer
• 10 mm Socket Wrench• Plumber's Tape
The 24-Month Maintenance Procedure starts by replacing the membrane air dryer, followed by the 12-Month Maintenance Procedure.
CAUTION: This procedure must be performed by trained, qualified personnel.
1. Replace the membrane air dryer.• The membrane air dryer and coalescing filter are
connected with a pipe fitting at the top. To replace either one, both are removed from the cabinet as a single unit, Figure 12.
• Locate the upper and lower tube connections. They are both quick-connect style fittings. Push in on the collar and pull the tube out.
• Remove the bowl on the coalescing filter by turning it to the left (counterclockwise). Set bowl with drain tube on cabinet floor.
• Locate the four (4) mounting studs, two (2) at the top of the coalescing filter and one (1) on each of the membrane air dryer brackets. Use a 10 mm socket to remove all four (4) nuts and washers and set aside.
• Pull the assembly out of the cabinet. Hold the membrane air dryer and unscrew the coalescing filter body.
NOTE: The membrane air dryer is plastic. The nipple fitting will most likely stay in the coalescing filter body. If it does not, then remove the nipple from the dryer and screw it into the coalescing filter body. Use plumber's tape on the threads.
Lower Tube Connection
Upper Tube Connection
Top Mounting Nuts
Lower Mounting
NutsFlow
Nipple (must stay in
coalescing filter)
Membrane Air Dryer
Figure 12 • Remove old plumber's tape from pipe nipple thread.
Use plumber's tape on the pipe nipple installed in the coalescing filter. Screw the new membrane air dryer (in correct flow orientation, Figure 12) and the filter together until hand tight. Make adjustments for mounting positions.
• Unscrew the lower tube connection fitting from the membrane air dryer. Remove old plumber's tape from the lower tube connection fitting. Apply three (3) wraps of new plumber's tape to the lower tube connection fitting. Install lower tube connection fitting into new membrane air dryer.
• Position the membrane air dryer into the original clamps. Then place the coalescing filter bracket onto the top mounting studs.
10 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
• Move the clamps for the membrane air dryer onto the studs. Install the two (2) washers and finger start the nuts. Install the two (2) washers over the two (2) studs for the coalescing filter body. Finger start the nuts on the filter bracket studs. Tighten all four (4) nuts.
• Connect the tubing to the upper and lower tube connections. Push the tubing into the fitting until it stops (bottoms).
2. Complete the 12-Month Maintenance Procedure on page 8.
TROUBLESHOOTINGSymptom Probable Cause Solution
Unit transmits electric current (electric shock)
Installation not according to local technical standardsShut down and call for service
Damage to electrical components
Excessive starts or greater than 500 hours runtime in six (6)
months
Leaks in restaurant plumbing downstream of compressor system Find leaks and repair to reduce compressed air demand
Pump-up time exceeds two (2) minutes, 50 secondsConsult Troubleshooting Section Pump-up time of Everpure
EverDri Compressed Air System greater than two (2) minutes, 50 seconds
Water in tank Consult Troubleshooting section "Water in tank"Air bypasses check valve Confirm function, clean or replace check valve
Restaurant airflow demand exceeds compressor capacity Call Pentair Technical Support
Pump-up time of Everpure EverDri Compressed Air System greater
than two (2) minutes, 50 seconds (follow pump-up procedure)
Leakage in fittings Tighten fittings to eliminate leakage or replace damaged parts
Cut-out pressure above specifications Adjust the pressure switch to meet specified cut-in and cut-out pressures
Leakage around pressure regulator knob Damaged pressure regulator Replace pressure regulator
Leakage from pop-safety valve Damaged pop-safety valve Replace pop-safety valveLeakage from pressure switch Damaged pressure switch Replace pressure switch
Plugged compressor inlet filters Replace compressor inlet filtersAir leakage through water drain tube
while compressor is running Coalescer drain stuck open Replace coalescer filter assembly
Coalescer leak between body and bowl O-ring seal is damaged or missing Replace coalescer filter assembly
Membrane air dryer defect Follow Troubleshooting procedure 1Piston rings are worn Replace piston rings and reed valves after eliminating other
potential causes as the source of high pump-up timeReed valves do not sealLeakage from compressor head gaskets/piston sleeve seal/crossover tube
seals Replace leaking seals/gaskets
Water in tank(Contact Technical Support)
Coalescing filter fails to remove liquid water from compressed air
Filter or drain failure Replace coalescer filter assemblyCoalescing filter water drain tube kinked or plugged Remove kink or obstruction
Improper extension of water drain tube
Remove drain tube extension and drain directly under enclosure
Membrane air dryer not functioning properly
Membrane air dryer defect Follow Troubleshooting procedure 1Membrane air dryer plumbed in reverse
Reverse orientation of membrane air dryer to confirm airflow direction matches flow arrow
Encloser cooling fan not functioning Replace enclosure cooling fan
11 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Symptom Probable Cause Solution
Insufficient air pressure
Pressure regulator is not adjusted properly Adjust pressure regulator to achieve specified outlet pressure
Compressor runs continuously and is unable to reach cut-out pressure
Restaurant airflow demand exceeds compressor capacity Call Pentair Technical Support
Tank pop-safety valve opens and relieves pressure Replace pop-safety valve
Pump-up time exceeds two (2) minutes, 50 seconds
Consult Troubleshooting Section Pump-up time of Everpure EverDri Compressed Air System greater than two (2)
minutes, 50 secondsLeaks in restaurant plumbing downstream of compressor system
Find leaks and repair to reduce compressor air demand
Excessive pressure drop between the Everpure EverDri compressed air system
and the application
Air leakage or obstruction Eliminate leakage or obstructionTubing is the wrong dimensions (tubing diameter is too small) Replace tubing with proper size tubing
Pressure gauge does not indicate correct pressure Replace pressure gauge
Cabinet ball valve not completely open Open the valve
Motor does not start or does not restart
Voltage drop or no power to unit Wait for the power to go back on
Circuit breaker turned off
Circuit breaker was turned off manually Turn on circuit breaker
Circuit breaker tripped due to circuit overload Call for service
Damaged electric motorReplace compressor pump assemblyCompressor pump assembly seized
Thermal protector not functional
Electric motor overheats, thermal protection trips
Temperature too high Wait for the temperature to stabilize and automatic reset to engage
Stator covered with dust Clean dust and debris off electric motor, check enclosure fan filter, replace compressor pump assembly if necessary
Vent filter plugged, poor airflow Replace fan and vent filters
Vent filters blocked, poor airflow Allow 6" clearance on left and right side of enclosure
Enclosure cooling fan not functioning Replace enclosure cooling fan
Working pressure too high Adjust the pressure switch to meet specified cut-in and cut-out pressures
Rotation direction of motor is incorrect. Call for service
Pressure relief valve not functioning, compressed air is retained upstream of check valve Replace pressure switch
Damaged pressure switchUse of underrated power supply Use power supply rated for 15AUnderrated extension cord in use Ensure power cable is rated for 15A
Damaged or faulty capacitor Replace capacitorLoose electrical connections Check and rewire electrical connections
Air bypasses check valve Test check valve, clean it or replace valveRestart attempted within one (1) minute of manual shutoff/unplugging Wait more than 60 seconds for pressure to escape
Tank pressure is above cut-in pressure Normal operation, no action is required. Compressor will automatically cycle between cut-in and cut-out pressure
12 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Symptom Probable Cause Solution
Unusual noise
Compressor's internal parts are worn out Confirm function, replace compressor pump assemblyCheck valve is making noise Confirm function, clean or replace check valve
Loose items vibrating inside enclosure Tighten or replace loose itemsBroken items vibrating inside enclosure Replace broken items
Broken or loose compressor foot/leg Tighten bolts holding compressor or tighten legs on enclosure
Motor does not shut off at or above cut-out pressure
Tank pop-safety valve opens and relieves pressure
Damaged pressure switch Replace pressure switchPressure switch settings adjusted incorrectly
Adjust the pressure switch to meet specified cut-in and cut-out pressures
NOTE: If leaks persist, or if there are other leaks in the system, remove power and call Technical Support 800.942.1153 (US only)/630.307.3000.
Troubleshooting Procedure 1 - Test Air Dryer FunctionTo determine if the membrane air dryer is functioning properly:
Step 1 Measure the regular pump-up time of the compressor according to procedure. Note the pump-up time (in seconds) for future reference.
Step 2 Unplug compressor system. Reroute tubing to bypass the coalescing filter and membrane air dryer. To do this, connect the aftercooler outlet to the tank inlet. The coalescing filter inlet and air dryer outlet tubing should not be connected to any fittings.
Step 3 Measure the modified pump-up time of the compressor according to procedure. Note the pump-up time (in seconds) for future reference.
Step 4 Unplug compressor system.Step 5 Divide the regular pump-up time by the modified
pump-up time. If the result is greater than 1.25, the membrane air dryer is damaged. Replace membrane air dryer. e.g. Regular pump-up time (149 seconds)
Modified pump-up time (111 seconds)
Step 6 Drain all air from the compressor tank.Step 7 Return all tubing to correct connections.
Call Pentair Technical Support for assistance if needed.
= 1.34
Troubleshooting Procedure 2 - Leaks at Quick-Connect Fittings
1. Remove power.
2. CLOSE the pressure side ball valve to the applications.
NOTE: If needed, change the position of the crossover valve to use back-up CO2.
3. OPEN the valve at the bottom of the storage tank to relieve pressure.
4. Press collar around the quick-connect fitting while pulling the tubing with your other hand.
5. Tubing should be cut squarely. Internal and external burrs should be removed. Place a mark on tubing 5/8" (1.6 cm) from end on 1/4" tubing or 3/4" (1.0 cm) from end on 3/8" tubing.
6. Wet the end and insert tubing until it stops (bottoms out) and the mark is flush with the quick-connect fitting.
7. CLOSE the tank valve.
8. Apply power and bring the system up to pressure. Check for leaks.
13 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
GAS FLOW SYSTEM SCHEMATIC
For an Everpure EverDri Compressed Air System
AIR/CO2 Flow Chart and Pressure Settings
Cut in 95 psiCut out 125 psi
95 psi
3/8" ID 3/8" ID
3/8" ID
3/8" ID
3/8" ID 3/8" ID 1/4" ID
Multiplex or Backroom package95 psi Multiplex
105 psi Backroom packageAir to All Equipment Only
ABS in Drive Thru
90 psi
Ketchup SystemSSBB 25 psi
Prep Line 30 psiair
Blended Ice
90 psiair
BIB System65 psi
Air
Bulk Sweet Tea
60 psiAir
Crossover
Compressed Air System
Everpure
air
Back up CompressedGas
COALESCING FILTER PART IDENTIFICATION
Body
Gasket
Filter Element
O-Ring
Automatic Piston Drain Seat
Automatic Piston Drain
Metal Bowl
Drain TubingOetiker Hose Clamp
WACO2 CONNECTIONS
Appl
icat
ions
Backup CO2 Tank Inlet
Compressed Air Inlet
TeaBIB
14 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
PNEUMATIC DIAGRAM
PressureVessel
Aftercooler MembraneAir Dryer
Check Valve
Emergency PressureRelief Valve
Vessel DrainBall Valve
PressureGauge
Pressure Switch
InletFilter
Outlet BallValve
Enclosure
Pressure Regulator
M
Compressor and Motor Assembly
ExhaustFilters
PressureRelief Valve
Inlet Filterand Fan
Coalescing Filter with Automatic Drain
WaterDrain
PressureGauge
Outlet
ELECTRICAL DIAGRAM
15 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
REPLACEMENT PARTS
CabinetContact your local Pentair® Everpure® Dealer for filter cartridges or system replacement parts.
1
2
3
6
5
4
Number Part Number Description
1 ACS-M017 Vent Filter Housing
2 FBSVM02FO2 Outlet Ball Valve
3 ACS-M022 Enclosure Door
4 ACS-M016 Stainless Legs
5 E-BREAKER-15A Circuit Breaker
6 ACS-M018 Inlet Fan
16 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Compressor
7
8
9
18
12
10
17
16
15
14
12
13
11
19
Number Part Number Description
7 ACS-M015 Compressor Assembly
8 ACS-M004 Compressor Pump Assembly
9 DFC0644M03P Compressor Inlet Filter
10 FBSNM04NM02 Nipple, 1/4" NPT x 1/2" NPT
11 SSHOSE-NO4-15 Hose, Stainless Steel
12 FPLNM02TF039SW Elbow, Push-To-Connect
13 FBSNF02CF03 Fitting, 3/8" Compression x 3/8" Push-To-Connect
14 ACS-M007 Check Valve
15 ACS-M008 Pressure Switch
16 ACS-M010 Pressure Gauge
17 ACS-M009 Regulator
18 ACS-M012 Drain Valve
19 ACS-M013 Vibration Isolators (pack of 4)
17 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Aftercooler and Filters
12
28
252726
23
24
22
20
1221
Number Part Number Description
20 FALNM02HNS Aluminum Nipple, 1/4" NPT
21 CLAMP-32-PIPE Dryer Pipe Clamp
22 AHD100721-1A-B Membrane Air Dryer
23 ACS-M021 Neoprene Tubing
24 H-HSCLMP-11.3MM Hose Clamp
25 ACS-M019 Coalescer Filter Assembly
26 FPLNM02TF03 Fitting, Push-To-Connect Straight
27 ACS-M020 Nylon Tubing, 3/8" OD
12 FPLNM02TF039SW Fitting, Push-To-Connect Elbow
28 ACS-M014 Aftercooler Assembly
18 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
Miscellaneous Replacement Parts
Number Part Number Description
* ACS151201-6MO Six (6) Month Maintenance Kit (Service Kit #1)
* ACS151201-12MO 12-Month Maintenance Kit (Service Kit #2)
* ACS151201-24MO 24-Month Maintenance Kit (Service Kit #3)
* ACS-M001 Fan Inlet Filter
* ACS-M002 Vent Filter
* PFH0011-EY Coalescer Filter Element
* ACS-M003 Capacitor
* ACS-M005 Piston Ring Kit (both cylinders)
* ACS-M006 Reed Valve Kit (both cylinders)
* ACS-M011 Pop-Safety Valve
* E-HBL5266C Electrical Plug
* ACS-HARNESS Wiring Harness
* Not Shown
McDonald's Compressor Filter Kits
NOTE: Sequence of kit installation is Kit #1, #2, #1, #3, RepeatMcDonalds Compressor Filter Kits
Description
Kit #1 (6 mo, 18 mo, 30 mo, 42 mo, 54 mo)
ACS151201-6MO Compressor Intake Air Filter- Qty 2
Fan Filter
Kit #2 (12 mo, 36 mo, 60 mo) ACS151201-12MO Coalescing Filter
Compressor Intake Air Filter - Qty 2
Fan Filter
Air Vent Filter - Qty 2
Kit #3 (24 mo, 48 mo, 72 mo) ACS151201-24MO Membrane Air Dryer
Coalescing Filter
Compressor Intake Air Filter - Qty 2
Fan Filter
Air Vent Filter - Qty 2
19 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
LIMITED WARRANTYEVERDRI COMPRESSED AIR SYSTEM WARRANTY
Pentair Filtration Solutions, LLC (“PFS”) offers the following product warranty for its EverDri Compressed Air System (the “Product”). This Product (excluding replaceable elements) is warranted against defects in materials and workmanship to the original end-user when installed in accordance with the PFS’ specifications. The warranty period commences on the date of purchase from PFS and continues for a period of:
Twenty-five (25) months or two thousand (2,000) hours of operation, as evidenced by the counter on the side of the Product, whichever occurs first.Replacement parts (“Parts”) shall be warrantied for the remainder of the original warranty period, or thirty days, whichever is longer.
Exclusions From This Limited WarrantyThis warranty does not cover the following instances:
1. Damage caused by careless handling, improper repackaging, or shipping
2. Damage due to misapplication, misuse, abuse or failure to operate or install Products as specified in owner’s manual
3. Any parts manufactured by a third party, including, but not limited to, repair and service parts, repair kits, motors, pistons, seal kits, and devices, or any other non-PFS parts. Incorporation of any parts manufactured by a third party into a PFS Product shall completely void the limited warranty for such Product.
4. Damage due to unauthorized Product modifications or failure to use our original replacement Parts
5. Damage caused by negligence, or failure to properly maintain Products as specified in the owner’s manual
6. Due to environmental or air conditions, some Products or Parts may require maintenance or cleaning during the warranty period. Products or Parts returned due to debris build up, including, but not limited to, plugged filters, are not covered under this warranty.
7. Noncompliance with applicable codes and ordinances.
8. Damage due to impacts, corrosive liquids, gases, or chemicals.
9. Damage caused by incorrect or improper determination of the proper Product necessary for the application
10. Damage caused by water freezing inside the Product
11. Accidental damage, fire, acts of God, or other circumstances outside of our control
12. Freight, transportation and labor expenses
13. Wear Parts Consumables, including but not limited to pistons, piston rods and rings, crankshaft, bearings and bearing retainers, valves, and parts requiring replacement under recommended maintenance procedures, such as filters.
Our Warranty Obligations Should a defect in workmanship and/or materials in Products or Parts covered by this warranty become evident during the applicable warranty period, then upon your compliance with the procedures below, we will, at our sole option, repair, or replace such Product or Part, or issue a credit of equal value, in lieu of repair.
We are not, however, responsible under this warranty for any cost of shipping or transportation of the Product or parts thereof to or from our facility. Also, we are not liable for any loss of time, inconvenience, incidental expenses such as telephone calls, labor, travel or material charges incurred in connection with the removal or replacement of the Product or Part, or any other incidental or consequential damages.
The above mentioned warranties are void if the product is repaired or altered in any way by any persons, agents or representatives other than those authorized by us.
20 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
NOTE: Pentair reserves the right to alter its product without prior notice. Figures, dimensions and photos are only for orientation. Use Pentair original parts only for service.
PLEASE NOTE: Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local environmental and air conditions and consumption. The quality of air supplies may vary seasonally or over a period of time. Air characteristics can also differ considerably if this product is moved to a new location. For these reasons, we assume no liability for the determination of the proper equipment necessary to meet your requirements, and we do not authorize others to assume such obligations for us.
No Other WarrantiesTO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, WE DISCLAIM ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT(S),PART(S) AND/OR ANY ACCOMPANYING WRITTEN MATERIALS.
Procedure for Obtaining WarrantyThe Product manual requires service to be performed on the Product every six (6) months from date of installation. The Product manual includes a service log, on which service which has been performed can be documented. In all instances of a Product or Part warranty claim, and prior to providing any warranty remedy, written documentation of all service performed on the Product must be submitted to PFS. A copy of the service log found in the manual, or receipts evidencing service performed (including dates and services performed) are acceptable forms of documentation.
In order to obtain the benefits of this warranty, the original purchaser must contact the Customer Care Department as soon as possible after discovery of the product or part related issue, but in no event later than the expiration date of the respective warranty periods provided herein. Upon receipt of this communication, we will promptly notify you of the address to which the Product or part may be shipped. You shall then ship the Product or Part, freight prepaid, to the address indicated, together with a “RETURN GOODS AUTHORIZATION” form obtained from Customer Care and a brief description of the problems encountered. Unauthorized returns will not be accepted. Freight must be prepaid by you.
Warranties or Representations by OthersNo third party has any authority to make any warranties or representation concerning us or our Products and Parts. Accordingly, we are not responsible for any such warranties or representations.
Other Rights
This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.
Sole WarrantyThis warranty supersedes all previous warranty publications.
Pentair Filtration Solutions, LLC.1040 Muirfield Drive Hanover Park, IL 60133 United States
Pentair Everpure Technical Service:
800.942.1153 / 630.307.3000
21 EVERPURE® EVERDRI™ COMPRESSED AIR SYSTEM INSTALLATION AND OPERATION GUIDE
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.
© 2016 Pentair Filtration Solutions, LLC. All Rights Reserved. EV3148-67 RevB OC16
WATER QUALITY SYSTEMS EVERPURE-SHURFLO WORLD HEADQUARTERS, 1040 MUIRFIELD DRIVE, HANOVER PARK, IL 60133 USA • FOODSERVICE.PENTAIR.COM 800.942.1153 (US ONLY) • 630.307.3000 MAIN • 630.307.3030 FAX • [email protected] EMAILEVERPURE-SHURFLO AUSTRALIA, 1-21 MONASH DRIVE, DANDENONG SOUTH, VIC 3175, AUSTRALIA 011.1300 576 190 TEL • 011.61.39.562.7237 FAX • [email protected] EMAILEVERPURE-SHURFLO CHINA, 21F CLOUD 9 PLAZA, NO 1118, SHANGHAI, 200052, CHINA 86.21.3211.4588 TEL • 86.21.3211.4580 FAX • [email protected] EMAILEVERPURE-SHURFLO INDIA, GREEN BOULEVARD, B-9/A, 7TH FLOOR - TOWER B SECTOR 62, NOIDA - 201301 91.120.419.9444 TEL • 91.120.419.9400 FAX • [email protected] EMAILEVERPURE-SHURFLO EUROPE, PENTAIR WATER BELGIUM BVBA, INDUSTRIEPARK WOLFSTEE, TOEKOMSTLAAN 30, B-2200 HERENTALS, BELGIUM +32.(0).14.283.504 TEL • +32.(0).14.283.505 FAX • [email protected] EMAILEVERPURE-SHURFLO JAPAN INC., HASHIMOTO MN BLDG. 7F, 3-25-1 HASHIMOTO, MIDORI-KU, SAGAMIHARA-SHI KANAGAWA 252-0143, JAPAN 81.(0)42.775.3011 TEL • 81.(0)42.775.3015 FAX • [email protected] EMAILEVERPURE-SHURFLO SOUTHEAST ASIA, SOUTHEAST ASIA, 390 HAVELOCK ROAD, #04-01 KING’S CENTRE, SINGAPORE 169662 65.6768.5800 TEL • 65.6737.5149 FAX • [email protected] EMAIL
Installation Site
Installer
Manufac-ture
InstallationServiceKit #1
ServiceKit #2
ServiceKit #1
ServiceKit #3
ServiceKit #1
ServiceKit #2
ServiceKit #1
ServiceKit #3
Hour-M
eterReading
hrs
New
Fan IntakeFilter
New
Compressor
Intake Filters (X2)
New
VentFilters (X2)
New
CoalescerFilter
New
Mem
braneAir Dryer
Pump up tim
e(0 - ~125psi)
min &
sec#' #"
Other Maintenance Com
pleted (piston rings, reed valves etc.)
Today's Date
SERVICE MUST BE COM
PLETED EVERY SIX MON
THS
Compressor
Serial Num
ber
Everpure EVERDRI High Capacity Compressed Air System
Services Log
Installation Site
Installer
Manufac-ture
InstallationServiceKit #1
ServiceKit #2
ServiceKit #1
ServiceKit #3
ServiceKit #1
ServiceKit #2
ServiceKit #1
ServiceKit #3
Hour-M
eterReading
hrs
New
Fan IntakeFilter
New
Compressor
Intake Filters (X2)
New
VentFilters (X2)
New
CoalescerFilter
New
Mem
braneAir Dryer
Pump up tim
e(0 - ~125psi)
min &
sec#' #"
Other Maintenance Com
pleted (piston rings, reed valves etc.)
Today's Date
SERVICE MUST BE COM
PLETED EVERY SIX MON
THS
Compressor
Serial Num
ber
Everpure EVERDRI High Capacity Compressed Air System
Services Log