File: NEGST1_D5 NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6 SUMMARY On-site evaluations of three solar thermal heating system concepts were carried out. These are the compact combisystem unit with gas auxiliary heater (REBUS-gas), the unit with pellets auxiliary heater (REBUS-pellet) and the integrated collector storage system ICS (Solior). The measurements followed the theoretical system evaluation which was also part of NEGST (/NEGST/). The theoretical evaluation of promising system concepts is described in /Vog06/, which also contains a des- cription of each of the systems. Besides these three system concepts which were field-evaluated in detail with measure- ments, other systems evaluated theoretically were very successful on the market before the end of the project. Two of these systems are the Compact heating unit for solar domestic hot water (SDHW) preparation (auroCOMPACT) and the solar heating system concept with water filled collector loop (AquaSystem). Thanks to the large number of installed systems, many experiences could be gained. This report summarizes the results of the field measurements taken on the three system concepts evaluated scientifically. Also it includes some of the experiences gained from the system types installed in large numbers and directs the reader to two separate reports where the experiences are described in more detail. This following section SELECTED RESULTS presents highlights of the evaluation. The complete information can be found in the documents mentioned below and listed in the section REFERENCES. As a general result it can be stated that: The system performance often exceeded the expectations. Secondary benefits turned out to be important (e.g.: the marketing of the system concept with water filled collector loop was particularly successful because the concept turned out to be well suited for retrofit installations; the reduction of circulation heat losses, enabled by the controller of the REBUS-gas system, contributed significantly to the gas savings observed in the demonstration house during the on- site evaluation). The main authors of the most important sections of this report are: Alexander Thür (reporting on REBUS-gas); Chris Bales (REBUS-pellet); Anton Schaap (ICS, Solior). WP1.D5 / RESULTS OF THE ON-SITE EVALUATION OF THE NEW SYSTEM GENERATION Dissemination level: public Authors: Peter Vogelsanger (editor), Chris Bales Alexander Thür, Anton Schaap Reviewer: Harald Drück August 2007 CONTENTS SUMMARY SELECTED RESULTS Combisystem unit with integrated gas auxiliary heater (REBUS-gas) Combisystem unit with integrated pellets auxiliary heater (REBUS-pellet) Integrated collector storage (ICS, Solior) System concept with water filled collector loop (AquaSystem) Compact heating unit for solar domestic hot water preparation (auroCOMPACT) DISSEMINATION OF THE RESULTS OF THE ON-SITE EVALUATION REFERENCES ACKNOWLEDGEMENTS

Upload: others

Post on 03-Feb-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

File: NEGST1_D5

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

SUMMARY

On-site evaluations of three solar thermal heating system concepts were carried out. These are the compact combisystem unit with gas auxiliary heater (REBUS-gas), the unit with pellets auxiliary heater (REBUS-pellet) and the integrated collector storage system ICS (Solior). The measurements followed the theoretical system evaluation which was also part of NEGST (/NEGST/). The theoretical evaluation of promising system concepts is described in /Vog06/, which also contains a des-cription of each of the systems. Besides these three system concepts which were field-evaluated in detail with measure-ments, other systems evaluated theoretically were very successful on the market before the end of the project. Two of these systems are the Compact heating unit for solar domestic hot water (SDHW) preparation (auroCOMPACT) and the solar heating system concept with water filled collector loop (AquaSystem). Thanks to the large number of installed systems, many experiences could be gained. This report summarizes the results of the field measurements taken on the three system concepts evaluated scientifically. Also it includes some of the experiences gained from the system types installed in large numbers and directs the reader to two separate reports where the experiences are described in more detail. This following section SELECTED RESULTS presents highlights of the evaluation. The complete information can be found in the documents mentioned below and listed in the section REFERENCES. As a general result it can be stated that:

The system performance often exceeded the expectations.

Secondary benefits turned out to be important (e.g.: the marketing of the system concept with water filled collector loop was particularly successful because the concept turned out to be well suited for retrofit installations; the reduction of circulation heat losses, enabled by the controller of the REBUS-gas system, contributed significantly to the gas savings observed in the demonstration house during the on-site evaluation).

The main authors of the most important sections of this report are: Alexander Thür (reporting on REBUS-gas); Chris Bales (REBUS-pellet); Anton Schaap (ICS, Solior).

WP1.D5 / RESULTS OF THE ON-SITE EVALUATION OF THE NEW SYSTEM

GENERATION

Dissemination level: public

Authors: Peter Vogelsanger (editor), Chris Bales

Alexander Thür, Anton Schaap

Reviewer: Harald Drück

August 2007

CONTENTS

SUMMARY

SELECTED RESULTS

Combisystem unit with integrated gas auxiliary heater (REBUS-gas)

Combisystem unit with integrated pellets auxiliary heater (REBUS-pellet)

Integrated collector storage (ICS, Solior)

System concept with water filled collector loop (AquaSystem)

Compact heating unit for solar domestic hot water preparation (auroCOMPACT)

DISSEMINATION OF THE RESULTS OF THE ON-SITE EVALUATION

REFERENCES

ACKNOWLEDGEMENTS

On-site evaluation August 2007 page 2 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

SELECTED RESULTS

Combisystem unit with integrated gas auxiliary heater (REBUS-gas)

Boundary conditions for a Danish/Swedish solar combisystem The Danish energy sources for heating residential buildings are mainly based on natural gas or district heating. This is why a concept of a solar combisystem in combination with a condensing natural gas boiler was developed in Denmark in close cooperation with the Danish main industry partner, Metro Therm A/S (/Thü06/, /Thü07/, /Fur07/). In Sweden, pellet heating is a common auxiliary heater in solar combisystems. In addition there are many electrically heated houses of which the space heating system will be converted to other energy sources in the next few years due to governmental incentive mechanisms. The REBUS concept shall be suited for both markets. Further main boundary conditions specific for the situation in Denmark are:

Till now, in Denmark solar combisystems are relatively small. Typical design figures are 8 m2

collector area and up to 300 litre domestic hot water storage volume, where the collector loop is directly connected to the space heating loop via a plate heat exchanger. This system design does not allow storage of solar heat in a water tank for space heating purposes, therefore the solar fraction is very low. In the last years, larger systems using several types of tank in tank concepts are used. Also due to the rising energy prices it is expected that the demand of competitive, advanced and compact solar combisystems is getting larger in future.

One-family houses in Denmark typically have no basement. Therefore, also no technical rooms exist where a lot of space is available to install the heating system. Due to this fact, heating systems are more or less integrated in the living area, which means that they are situated e.g. in the entrance room, the bathroom, the kitchen or a store room. Because the heating system is optically present in the living area, it is a strong need to have a nice design and to have all the pipes and other components hidden behind an optically nice façade. Also the space requirement for the installation should be minimized.

Since, due to the small market, the experience of installers in solar heating technology is typically rather low, a high degree of prefabrication of the solar combisystem is the best solution to avoid installation mistakes. Prefabrication typically also reduces the installation cost and increases the efficiency of the whole system.

The system design shall be flexible in order to be able to integrate boilers from different producers and different types of boiler (e.g. natural gas-, oil-, pellet boiler) as well. The system concept should also be easily usable for different system size which means solar heating systems with low to high solar fraction. A main focus shall be to develop a system concept including an advanced control algorithm which leads to best possible operating conditions for both the condensing natural gas boiler and the solar collector in order to get the highest possible overall system performance.

Description of the system Based on the boundary conditions described above, the following system concept was developed, which is shown in figure 1. The solar combisystem consists of two main units, the solar store unit and the technical unit. The solar store unit is integrated in a compact and nice looking cabinet with a ground area of 60 x 60 cm, as long as the volume is less than about 400 litres. For larger volumes, several such units can be connected in series and placed side by side. For reduced heat losses also a large single tank can be used which allows a hydraulic connection to the technical unit as it is needed according to the system concept (see also figure 2). The technical unit includes the controller and all hydraulic components (pumps, valves, expansion vessel, heat exchangers, etc.) which are needed to collect energy from the heat sources (boiler and solar collector) and to distribute it in the most efficient way directly to the demand (space heating loop or domestic hot water preparation) or to store the energy with a minimum of exergy losses according to the temperature level of the energy input and the actual stratification in the tank. This technical unit can be delivered to the installation site totally

On-site evaluation August 2007 page 3 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

prefabricated, also with the condensing natural gas boiler inside. Then the remaining installation work which needs to be done is only to connect the pipes between the technical unit and the solar store unit and between the technical unit and the piping in the house (space heating, domestic hot water, solar loop, natural gas and exhaust pipe) plus some small electrical work.

Solar Store Unit Technical Unit

HW

CW

Space Heating

Collector Loop

S

S

Radiators

Floor Heating

S

Domestic Hot Water

Boiler

11

22

33

44

55

(P4)

(V5)

(V4)(V3)

(V2)

(P3)

(V1)

(P1)

MM

MM

MM

(P2)

(P6)

Fig. 1: The compact solar combisystem as two units with 60 x 60 cm ground area: On the left side a solar tank and on the right side the prefabricated technical unit in which the condensing natural gas boiler, the controller and all the other components like pumps, switching valves, mixing valves, expansion vessels, plate heat exchanger, etc. are located.

Solar Store Unit Technical Unit

HW

CW

Space Heating

Collector Loop

S

S

Radiators

Floor Heating

S

Domestic Hot Water

Boiler

MM

MM

MM

Fig. 2: Hydraulic scheme of the solar combisystem.

On-site evaluation August 2007 page 4 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Due to the modular approach and the fact that the technical unit contains all parts necessary for a complete heating system, it can be sold on its own. It is then completely prepared for solar, which can be added at a later stage by installing the collector and connecting it to the technical unit and hydraulically connecting the technical unit to the solar store by 5 pipes. The main criteria when developing this system concept was to optimize the operating conditions for the two energy sources solar collector and condensing natural gas boiler. For high efficiency, both need lowest possible return temperatures. Unfortunately most of the condensing natural gas boilers have integrated bypass valves, which are raising the return flow temperature if the flow rate is lower than the allowed minimum flow rate. Typically, this minimum flow rate is between 450 and 600 litres per hour. But a radiator space heating system is operating with flow rates mostly between 100 and 400 litres. To make these different flow rates fit together, a buffer volume is needed. In combination with condensing natural gas boilers, which have sufficient high peak power (about 30 kW) for direct hot water preparation an advanced control concept can be used. The main difference of this concept is to use the auxiliary volume as a buffer, but NOT to keep the auxiliary volume at a high set temperature (typically 60-70°C) for domestic hot water prepa-ration. This is possible because the boiler is powerful enough to cover the domestic hot water demand directly. Therefore, the boiler is always operating at lowest possible forward tempe-rature including the possibility to use the auxiliary volume as a buffer. The advantage resulting from this approach is due to several effects:

Especially in wintertime, the average tank temperature in the top part is comparable low and therefore, also the heat loss of the tank is lower.

Since the average tank temperature in the top part is lower, this in fact is enlarging the heat capacity, which can be used by the solar collector to gain and store more solar energy into the same tank volume. Especially in small tanks (e.g. 90 litres auxiliary volume as part of a 300 litre tank) this can lead up to about 20% more effective useful heat capacity.

The average temperatures in the pipes connecting boiler and tank are lower and therefore again the heat losses are lower. This is also true for the hot forward flow pipe between the tank and the mixing valve.

Due to the lower temperature level the boiler in average is operated, higher condensation rates of a condensing natural gas boiler can be expected which is increasing the boiler efficiency.

Using an auxiliary buffer volume also is dramatically reducing the start/stop frequency of the boiler. This has positive effects on the reliability of the boiler components and the flue gas quality. Furthermore it leads to reduced emissions.

Furthermore, an advanced control strategy for the domestic hot water circulation pump was integrated, the so called circulation on demand . The circulation pump is not running all the time but switched (triggered) on when hot water is tapped. The pump continues to run for some time afterwards. Once the hot water circulation is activated, it takes about 20 seconds (in the demonstration house, which is described later) until hot water is available at the tap without continued tapping. If people are adapted to this system the short waiting time may be used for other activities and its disadvantage is small compared to the huge amount of energy saved.

Description of the demonstration house The demonstration house used for the REBUS-gas system is situated in the small town Helsinge, about 40 km north of Copenhagen (56°01' N, 012°12' E) and occupied by two adults and one teenager. The house shown in figure 3 has three floors: the basement with an entrance room, a bedroom, a bathroom and the technical room, the first floor with kitchen, living room and dining room and the second floor with two bedrooms and a bathroom. The house is about 9 m in length (east-west) and 7 m in width. Therefore, the gross area in the basement and the first floor is about 63 m2 and in the second floor 46 m2 which results in a total area of about 172 m2. The space heating distribution system mainly consists of several old cast iron radiators. The bedroom in the basement has floor heating with an extra pump with integrated mixing valve, which is controlled by a room temperature sensor. The other floor heating loops, each with a return temperature control thermostat valve, are in the entrance room and in the bathroom in the

On-site evaluation August 2007 page 5 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

basement as well as in the bathroom in the second floor. These floor heating loops are supplied with the same forward temperature as the radiators. The old heating system in this demonstration house was supplied with heat by a non condensing natural gas boiler. For domestic hot water preparation the natural gas boiler heated a hot water tank:

Natural gas boiler: Vaillant, nominal power: 22 kW; construction year: 1990

Domestic hot water tank volume: 50 litres

Number of pumps: 3; The main pump was integrated in the gas boiler, one extra pump for the floor heating in the bedroom in the basement and one hot water circulation pump.

Fig. 3: View on the demonstration house from the south (left) and the installed REBUS-gas solar heating system in the basement (right).

The new solar combisystem was equipped with the following components: Collector: VELUX, 5 pieces of type: S08 (D2178) Collector area: 6.75 m2 (aperture area) Tilt angle of the roof: 45° Azimuth of the roof: 15° East Condensing natural gas boiler: Distributor: Milton A/S Type: Milton Smart Line HR24 Nominal power, space heating: 5.7 23.0 kW Nominal power, hot water: 5.7 28.5 kW Solar tank:

Total volume: 360 litres Auxiliary volume: 90 litres

In order to have an as large as possible tank volume within the 60 x 60 cm cabinet a new tank was designed and produced as a prototype for this demonstration system. Standard tanks of Metro Therm A/S, which fit into a 60 x 60 cm cabinet, have a diameter of 500 mm. This prototype tank has a diameter of 550 mm and also fits into the 60 x 60 cm cabinet. Due to the 10% larger diameter, the volume of the tank increased by about 20%. In order to keep the heat loss in the same range, on the four sides, where the insulation thickness would be only 25 mm, vacuum panels with a thickness of 20 mm were embedded into the foam. Measurements at SERC (Solar Energy Research Center) in Sweden resulted in a heat loss coefficient of about 2 W/K (see figure 4).

On-site evaluation August 2007 page 6 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Fig. 4: Heat loss rate of the REBUS solar storage measured at SERC (red diamond), compared to test results of other solar stores as measured at ITW, University of Stuttgart (black diamonds).

Monitoring results In order to show an overview on the typical natural gas consumption the house owner was asked for the yearly natural gas consumption in the last years. For the following accounting periods the natural gas consumption and the heating degree days were: 6/5-2001 till 5/5-2002: 2,524 m3 (26,931 kWh) 2973 Kd 5/5-2002 till 28/4-2003: 2,693 m3 (28,734 kWh) 3243 Kd 28/4-2003 till 10/5-2004: 2,927 m3 (31,231 kWh) 3090 Kd

1/1-2005 till 31/12-2005: 2,355 m3 (25,131 kWh) 3097 Kd Space heating demand: 17,974 kWh; Domestic hot water consumption: 3,279 kWh (9.0 kWh/d)

Detailed monitoring in the demonstration house was done from January 2005 until May 2007. In May and June 2006 the old heating system was replaced by the new solar combisystem. In this period domestic hot water was prepared by a small electric powered domestic hot water heater. From July until September 2006 for the new solar combisystem only the natural gas consumption could be measured. In October 2006 detailed monitoring with several energy meters was started.

The measured natural gas consumption for the old conventional heating system (Old) and the new solar combisystem (SCS) for equivalent summer and winter periods are: Summer consumption 7/07-05 30/9-06 (85 days) Old: 1,509 kWh Summer consumption 7/07-06 30/9-07 (85 days) SCS: 318 kWh Winter consumption 1/10-05 30/4-06 (212 days) Old: 24,435 kWh (2982 Kd) Winter consumption 1/10-06 30/4-07 (212 days) SCS: 14,719 kWh (2232 Kd)

For the winter period it must be considered that, on the one hand, the heating degree days of the winter 2006/07 were about 25% lower compared to the winter before. On the other hand, since summer 2006 the basement in this house is used as living area and therefore heated as well. Furthermore since October 2006 the thermostatic valves were used correctly following instruction of the users. Before that time the thermostatic valves were used as simple on/off valves. In figure 5 and table 1 the monitoring results of the new solar combisystem for the period October 2006 until May 2007 are presented:

On-site evaluation August 2007 page 7 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

REBUS project Demonstration House - HELSINGEEnergy Balance - 10-2006 till 05-2007 - Monthly Values

0

400

800

1200

1600

2000

2400

2800

3200

Oct 06 Nov 06 Dec 06 Jan 07 Feb 07 Mar 07 Apr 07 May 07

En

erg

y [k

Wh

]

0%10%

20%30%40%

50%

60%70%

80%90%100%

110%120%

130%

140%150%160%

Eff

icie

ncy

[%

]

Solar Gain [kWh] Natural Gas Consumption [kWh] Space Heating [kWh]

Domestic Hot Water-Consumption [kWh] Domestic Hot Water-Circulation [kWh] Electricity [kWh]

Boiler Efficiency [%] Natural Gas - COP [%]

Hydraulic Efficiency [%]

Fig. 5: Energy balance of the new installed solar combisystem. The bars Domestic Hot Water

Circulation are small (values see table 1).

Table 1: Energy data of the new installed solar combisystem:

Am

bie

nt

Tem

per

atu

re

A

vera

ge

So

urc

e: D

MI

Nat

ura

l Gas

C

on

sum

pti

on

Lo

w H

eati

ng

Val

ue

= 10

.67

kWh

/m3

So

lar

Gai

n

Sp

ace

Hea

tin

g

Sp

ace

Hea

tin

g

T

emp

erat

ure

Dif

fere

nce

Mo

nth

ly a

vera

ge

Do

mes

tic

Ho

t W

ater

-C

on

sum

pti

on

Do

mes

tic

Ho

t W

ater

-C

on

sum

pti

on

Ave

rag

e d

aily

co

nsu

mp

tio

n

Do

mes

tic

Ho

t W

ater

C

on

sum

pti

on

T

emp

erat

ure

Dif

fere

nce

Mo

nth

ly a

vera

ge

Do

mes

tic

Ho

t W

ater

-C

ircu

lati

on

(21

/11-

05 t

ill

20/1

2-05

;

d

aily

6-1

0 an

d 1

7-20

)

Ele

ctri

city

co

nsu

mp

tio

n

per

day

To

tal h

eati

ng

Sys

tem

(fro

m 2

1/11

-05)

Bo

iler

Eff

icie

ncy

(B

oile

r/G

as)

Nat

ura

l Gas

- C

OP

(D

HW

+SH

)/(G

as)

C

ircu

lati

on

as

Lo

ss

So

lar

Fra

ctio

n

(S

ola

r)/(

So

lar+

Bo

iler)

Hyd

rau

lic E

ffic

ien

cy

(DH

W+S

H)/

(Gas

*eta

_bo

il+

So

lar)

C

ircu

lati

on

as

Lo

ss

Ta Gas Solar SH DHW Circ Electr. eta_boil COP SF eta_hyd[°C] [kWh] [kWh] [kWh] [K] [kWh] [kWh/d] [K] [kWh] [kWh/d] [%] [%] [%] [%]

10.2006 11.7 1266 143 1040 11.9 216 7.0 35.3 18 2.9 96.5% 99.2% 10.5% 92.0%11.2006 7.4 2146 66 1830 12.7 238 7.9 37.4 14 3.1 99.1% 96.4% 3.0% 94.3%12.2006 6.6 2244 27 1853 12.5 274 8.8 39.2 10 3.2 99.5% 94.8% 1.2% 94.1%01.2007 4.3 2828 30 2421 12.3 214 6.9 39.6 14 3.2 97.8% 93.2% 1.1% 94.2%02.2007 1.5 2953 59 2579 13.1 203 6.5 41.3 12 3.2 97.4% 94.2% 2.0% 94.8%03.2007 6.2 2116 312 1999 9.6 227 7.3 41.6 15 3.3 97.3% 105.2% 13.2% 93.9%04.2007 9 1166 472 1226 10.8 219 7.1 39.8 15 3.0 95.3% 123.9% 29.8% 91.2%05.2007 12.3 575 357 592 15.5 183 5.9 35.5 14 2.2 91.4% 134.9% 40.5% 87.8%

Total 15295 1466 13540 1774 7.3 112

The conditions (heating degree days, additional use of the basement, different operation of the thermostatic valves of the radiators, etc.) which occurred in the periods before and after the installation of the REBUS combisystem varied considerably. In order to be able to compare the old heating system and the new solar combisystem a coefficient of performance (COP) was defined. The COP is the domestic hot water plus space heating loads divided by the natural gas consumption. Figure 6 shows the COP for both the new and the old heating systems. In the case of the old heating system there is a clear dependency of the COP from the heat load. This dependency is not clear in the case of the new system because of the important contribution of solar energy. Also, a hydraulic efficiency was defined. It is the energy output from the heating unit (domestic hot water and space heating) divided by the heat input to the unit (solar and boiler). These definitions imply that the heat used for domestic hot water circulation is considered lost rather than utilized, which explains the remark Circulation as Loss in the columns COP and eta hyd of table 1.

On-site evaluation August 2007 page 8 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

50%

60%

70%

80%

90%

100%

110%

120%

130%

140%

0 500 1000 1500 2000 2500 3000 3500 4000

Monthly Load for Space Heating + Domestic Hot Water [kWh]

CO

P [

%]

Solar CombisystemOld Heating SystemPolynomisch (Old Heating System)

Fig. 6: Comparison of the coefficient of performance (COP) of the old heating system and the new solar combisystem.

With the dependency of the coefficient of performance (COP) from the total monthly heat load the natural gas consumption of the old heating system can be estimated for the period when the new REBUS system was in operation. Figure 7 and table 2 show the gas consumption of the old and the new system. Also the energy savings resulting from these figures are presented. 2482 kWh gas was saved during the 8 months period. The specific energy savings (per collector area) were 368 kWh/m2. The specific solar gain of the same period amounted to 217 kWh per square metre collector area.

Energy Savings per Month

0

500

1000

1500

2000

2500

3000

3500

10.2

006

11.2

006

12.2

006

01.2

007

02.2

007

03.2

007

04.2

007

05.2

007

Tot

al

[1

0 kW

h]

Ene

rgy

[kW

h],

Tot

al E

ner

gy

[10k

Wh]

0

20

40

60

80

100

120

140

CO

P [

%]

Natural Gas Consumption old [kWh] Heat Load [kWh]

Natural Gas Consumption SCS [kWh] Energy Savings [kWh]

COP SCS [%] COP old [%]

Fig. 7: Monthly energy consumption and energy savings of the new solar combisystem (SCS) compared to the old heating system.

October 2006

May 2007

February 2007

On-site evaluation August 2007 page 9 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Table 2: Energy savings of the new solar combisystem compared to the old heating system: Month

Heat Load (SH+DHW)

COP old

COP SCS

Natural Gas Consumption old

Natural Gas Consumption SCS

Energy Savings

Energy Savings

Solar Gain

[kWh] [%] [%] [kWh] [kWh] [kWh] [kWh/m2] [kWh/m2]10.2006 1256 88,2 99,2 1424 1266 158 23 21

11.2006 2068 86,5 96,4 2388 2146 242 36 10

12.2006 2127 86,4 94,8 2461 2244 217 32 4

01.2007 2635 85,4 93,2 3086 2828 258 38 4

02.2007 2782 85,1 94,2 3268 2953 315 47 9

03.2007 2226 86,2 105,2 2582 2116 466 69 46

04.2007 1445 87,8 123,9 1646 1166 480 71 70

05.2007 775 84,1 134,9 922 575 347 51 53

Total 15313 86,1 100,1 17776 15294 2482 368 217

In the months October 2006 to February 2007 the energy savings can be explained mainly by the higher efficiency of the condensing natural gas boiler compared to the old non condensing natural gas boiler (see also table 4). Detailed investigations showed that the boiler efficiency during this period is higher than expected (in comparison to typical installations). This improve-ment is due to the advantageous hydraulic integration inherent with the new system. During the 3 months March, April and May 2007 the solar collectors contributed significantly to the heating system, resulting in COP values clearly above 100%. In table 3 estimated figures for the complete year are presented. It is expected that the new solar combisystem (6.75 m2 collector area and 360 litre solar tank) will lead to energy savings of about 3750 kWh (20%). The specific savings (per square metre of collector area) are about 555 kWh/m2. The specific collector gain is expected to be about 433 kWh/m2.

Table 3: Estimated energy savings of the new solar combisystem (SCS) compared to the old heating system for one year (for June till September 2007 estimated values were used):

MonthHeat Load (SH+DHW)

COP old

COP SCS

Natural Gas Consumption old

Natural Gas Consumption SCS

Energy Savings

Energy Savings

Solar Gain

[kWh] [%] [%] [kWh] [kWh] [kWh] [kWh/m2] [kWh/m2]10.2006 1256 88,2 99,2 1424 1266 158 23 21

11.2006 2068 86,5 96,4 2388 2146 242 36 10

12.2006 2127 86,4 94,8 2461 2244 217 32 4

01.2007 2635 85,4 93,2 3086 2828 258 38 4

02.2007 2782 85,1 94,2 3268 2953 315 47 9

03.2007 2226 86,2 105,2 2582 2116 466 69 46

04.2007 1445 87,8 123,9 1646 1166 480 71 70

05.2007 775 84,1 134,9 922 575 347 51 53

06.2007 300 62,0 230,8 484 130 354 52 56

07.2007 160 50,0 800,0 320 20 300 44 55

08.2007 180 56,0 720,0 321 25 296 44 55

09.2007 500 75,0 142,9 667 350 317 47 50

Total 16453 84,1 104,0 19568 15819 3749 555 433

Table 4 shows an overview of the main monitoring data of the old heating system (January 2005 till April 2006) and the new solar combisystem (October 2006 till May 2007).

On-site evaluation August 2007 page 10 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Table 4: Overview of the main monitoring data of the old heating system and the new solar combisystem:

Am

bie

nt

Te

mp

era

ture

Ave

rag

e

S

ou

rce

: D

MI

Nat

ura

l G

as

Co

ns

um

pti

on

Lo

w H

eat

ing

Va

lue

= 1

0.67

kW

h/m

3

So

lar

Gai

n

Sp

ace

Hea

tin

g

Sp

ace

Hea

tin

g

T

emp

era

ture

Dif

fere

nce

Mo

nth

ly a

ver

age

Do

mes

tic

Ho

t W

ater

-C

on

sum

pti

on

Do

mes

tic

Ho

t W

ate

r-C

on

su

mp

tio

n

A

ver

age

dai

ly

con

sum

pti

on

Do

mes

tic

Ho

t W

ate

r C

on

su

mp

tio

n

Tem

pe

ratu

re D

iffe

ren

ce

Mo

nth

ly a

vera

ge

Do

mes

tic

Ho

t W

ate

r-C

ircu

lati

on

(21

/11-

05 t

ill

20/

12-0

5;

dai

ly 6

-10

and

17-

20)

Ele

ctr

icit

y co

nsu

mp

tio

n

per

da

y

T

ota

l hea

tin

g S

yste

m

(f

rom

21

/11-

05)

Bo

iler

Eff

icie

nc

y

(B

oile

r/G

as)

Nat

ura

l G

as

- C

OP

(D

HW

+SH

)/(G

as)

C

ircu

lati

on

as

Lo

ss

So

lar

Fra

ctio

n

(S

ola

r)/(

So

lar+

Bo

iler)

Hyd

rau

lic

Eff

icie

ncy

(D

HW

+S

H)/

(Ga

s*e

ta_

bo

il+

So

lar)

C

irc

ula

tio

n a

s L

os

s

Ta Gas Solar SH DHW Circ Electr. eta_boil COP SF eta_hyd[°C] [kWh] [kWh] [kWh] [K] [kWh] [kWh/d] [K] [kWh] [kWh/d] [%] [%] [%] [%]

01.2005 2,6 3055 0 2322 8,2 315 10,2 55,8 0 - 88,8% 86,3% - 97,2%02.2005 -0,3 3477 0 2665 10,3 350 12,5 57,1 0 - 89,1% 86,7% - 97,3%03.2005 0,9 3602 0 2822 10,4 324 10,5 57,0 0 - 89,9% 87,3% - 97,1%04.2005 7,8 2224 0 1685 6,6 292 9,7 54,6 0 - 92,5% 88,9% - 96,1%05.2005 11,0 1655 0 1207 5,7 257 8,3 52,6 0 - 93,6% 88,5% - 94,5%06.2005 14,1 1038 0 663 6,3 229 7,6 50,6 0 - 93,1% 85,9% - 92,2%07.2005 17,2 400 0 15 13,8 220 7,1 48,1 0 - 83,8% 58,8% - 70,1%08.2005 15,2 401 0 77 4,0 183 5,9 30,3 0 - 90,4% 64,9% - 71,8%09.2005 13,9 808 0 424 3,4 241 8,0 54,5 0 - 94,5% 82,3% - 87,0%10.2005 10,3 1890 0 1378 5,2 281 9,1 57,0 0 - 93,6% 87,8% - 93,8%11.2005 5,2 2926 0 2124 7,1 292 9,7 59,2 91 3,5 89,3% 82,6% - 92,5%12.2005 1,9 3654 0 2593 10,2 295 9,5 59,4 206 3,2 88,6% 79,0% - 89,2%

2005 25131 0 17974 7,7 3279 9,0 52,8 - - 90,4% 84,6% - 93,6%

01.2006 -1,6 4639 0 3693 11,2 247 8,0 59,6 0 3,4 87,4% 84,9% - 97,1%02.2006 -0,2 3871 0 2978 10,1 267 9,5 61,9 0 3,3 87,2% 83,8% - 96,1%03.2006 -1,1 4257 0 3243 10,8 300 9,7 62,6 0 3,4 86,4% 83,2% - 96,4%04.2006 5,9 2928 0 2210 7,0 259 8,6 61,5 0 3,3 89,1% 84,3% - 94,7%05.2006 11,506.2006 15,8 Installation of the new solar combisystem.07.2006 20,308.2006 16,9 Installation of the new measurement equipment.09.2006 16,010.2006 11,7 1266 143 1040 11,9 216 7,0 35,3 18 2,9 96,5% 99,2% 10,5% 92,0%11.2006 7,4 2146 66 1830 12,7 238 7,9 37,4 14 3,1 99,1% 96,4% 3,0% 94,3%12.2006 6,6 2244 27 1853 12,5 274 8,8 39,2 10 3,2 99,5% 94,8% 1,2% 94,1%01.2007 4,3 2828 30 2421 12,3 214 6,9 39,6 14 3,2 97,8% 93,2% 1,1% 94,2%02.2007 1,5 2953 59 2579 13,1 203 6,5 41,3 12 3,2 97,4% 94,2% 2,0% 94,8%03.2007 6,2 2116 312 1999 9,6 227 7,3 41,6 15 3,3 97,3% 105,2% 13,2% 93,9%04.2007 9 1166 472 1226 10,8 219 7,1 39,8 15 3,0 95,3% 123,9% 29,8% 91,2%05.2007 12,3 575 357 592 15,5 183 5,9 35,5 14 2,2 91,4% 134,9% 40,5% 87,8%

Conclusions

Major improvements could be achieved by significantly reducing the domestic hot water energy consumption of about 20%, mainly due to a reduced hot water set temperature of 50°C instead of almost 70°C before. This smaller temperature reduced quite strong the heat losses of the pipes due to a 40% lower temperature difference (50/20 instead of 70/20).

The efficient concept of circulation on demand could be demonstrated very successfully. The hot water circulation losses of the newly installed solar combisystem are less than 10% relative to the whole domestic hot water consumption. In several studies circulation heat losses of 50 to 100% are reported as typical values. Also, in this demonstration house the circulation losses from November 21st till December 21st, 2005 were in total 297 kWh representing almost exactly 100% of the domestic hot water consumption which was at that time period 292 and 295 kWh respectively.

The electricity consumption in the new solar combisystem during the heating period was about 5% lower compared to the old heating system even though that in total 3 pumps more were installed. A major reduction could be realized by the possibility to adapt the space heating pump speed to the real demand using the integrated pump speed controller.

The hydraulic efficiency of the new solar combisystem could be demonstrated to be comparable very high. Despite the fact that the solar storage tank has an about 7 times larger volume (360 litres of the solar storage tank compared to 50 litres of the domestic hot water tank of the old system) and the effort of piping and the number of components is naturally somewhat higher, the hydraulic efficiency of 90 to 95% during the core heating season is a quite high value if compared to results from other field measurements (/Wol04/).

More detailed information on the system and its on-site evaluation is available in /Fur07/ which covers both the compact heating unit (REBUS) with gas and pellets auxiliary heater.

On-site evaluation August 2007 page 11 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Combisystem unit with integrated pellets auxiliary heater (REBUS-pellet)

Demonstration Site Initial field testing of the compact solar heating unit with a pellets auxiliary heater (/Fie05/, /Fie07/) was carried out on one installed system. A number of different potential sites for the demonstration system were checked to select a well suited test site. The house was built around 1910 and has been refurbished a couple of times since then. Until the beginning of 2006 the house was heated by electric heater panels and for domestic hot water preparation an electrically heated store was used. The owner was very interested in converting to a pellets and solar heating system due to the high heating costs with electricity. The house is quite typical for houses of that age. There are approximately 40.000 houses of this house type of the roughly 500.000 electrically heated houses in Sweden in total. There is also a garage/workshop on the property that is also heated electrically. Before the installation of the REBUS solar thermal system, approx. 23.000 kWh/a electricity was used in the main house and the garage/workshop as well as small amounts of log wood for heating in the main house.

Installation During the spring of 2006 a number of water based radiators were installed in the main house and the electrical panel heaters were removed. The panel heaters have been kept in the garage, although it is planned to make a culvert to the garage and supply heat from the REBUS system at a later date. The REBUS system was installed in the middle of July 2006 without the pellet stove because of technical problems with the chimney. The stove was installed in the middle of October 2006. Up until this date a 6 kW electrical heater in the 80 litre standby store in the technical unit was used as auxiliary heater. The pellets stove is situated in the middle of the living room and is fed manually by the owners (see figure 9, below, middle). The technical and store units were installed in a small room/cupboard under the stairs requiring the technical unit to be lower than standard height (see figure 10, right). To match these requirements, it was possible with the chosen system variant with separate pellet stove. The collector field of 10 m2

(figure 8, left) consists of four modules of Svesol premium AR with a standard rated output of 465 kWh/a for Stockholm weather conditions at a constant temperature of 50°C. The collector was placed on the main roof facing 40°E with a slope of 40°.

Fig. 8 - 10: The demonstration site in Borlänge, with (8, left) view of the 10 m2 collector array on the roof; (9, middle) water jacketed pellets stove and (10, right) technical and store units in a cupboard under the stairs.

Monitoring Results Monitoring started at the end of July 2006, thus detailed results are presented for August 2006 onwards. The owner has kept good records of bought energy for the year previous to the

On-site evaluation August 2007 page 12 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

installation, and these values are presented in some of the figures. The amount of log wood used was estimated by the user and the tiled stove using log wood was assumed to have an efficiency of 50%. Figure 11 shows the REBUS system schematic with sensor positions for the REBUS controller (blue with subscript c) and the monitoring system (red with subscript d). A simple pyranometer has been used to measure the global solar radiation (not shown). The data were logged using a Campbell CR10 data logger with attached multiplexers. Average data values were stored with an interval of one minute.

Fig. 11: REBUS system schematic with sensor positions for the REBUS controller (blue with subscript c) and the monitoring system (red with subscript d).

Figure 12 shows the monthly energy supply to the demonstration house. Autumn 2007 was very mild, with higher ambient temperatures than normal. This is reflected in the relatively low energy supply figures. The electricity supply to the REBUS system was high until the middle of October due to the fact that all auxiliary heat was supplied by electricity as the stove was not yet installed. In all following months, the REBUS system required very little electricity. Almost no auxiliary heat was required during August and September (see more details later).

Monitoring Demosystem 2006-10-10

Td25 = Toutside

Sensors monitoring data logger

Sensors controller

Td29 = Thr (heating room)

Solar Store Unit

Pellet stove

4

1

2

3

(Tc1)

Tc2

Tc3

Tc45

Combustionair

Fluegas

Standby

store

Td14.1

Td27

Td1

Td2

Td3

Td4Td26

Td1.1

Td18.1

Tc1

Pel

Collector loop

Tc5

(P4)

S

DI1

S

S

(P3)

HW

CW

Radiators

Tc11

Td13.2

Td10

Td14.2

Td11

Tc10

Tc12

Tc14

Fd2

Fd3

Tc18

Tc8

Td8

Td24Fd1

(V2)

(V4)

(V3)

(V1)

(V7)

(P1)

(P2)

Td18.2

Td23

Td12

Fd4

Tc13

(V5)

AAB

B

A

B

AB

A

AB

B

B

AB

A

Technical Unit

Buffer

store

Tc19 = Troom

Tc20 = Toutside

Td13.1

Tc9

A

AB

B

A

AB

B

On-site evaluation August 2007 page 13 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

0

500

1000

1500

2000

2500

3000

3500

Jan-

06

Feb

-06

Mar

-06

Apr

-06

May

-06

Jun-

06

Jul-0

6

Aug

-06

Sep

-06

Oct

-06

Nov

-06

Dec

-06

Jan-

07

Feb

-07

Mar

-07

Apr

-07

May

-07

Jun-

07

En

erg

y su

pp

ly [k

Wh

]

Wood [kWh]

Electr. REBUS heater [kWh]

Pellet [kWh]

Solar [kWh]

Electricity SH + DHW [kWh]*

Fig. 12: Monthly energy supply to the demonstration house (not including the garage) of the REBUS pellet and solar heating system during 2006.

0

500

1000

1500

2000

2500

3000

3500

Jan-

06

Feb

-06

Mar

-06

Apr

-06

May

-06

Jun-

06

Jul-0

6

Aug

-06

Sep

-06

Oct

-06

Nov

-06

Dec

-06

Jan-

07

Feb

-07

Mar

-07

Apr

-07

May

-07

Jun-

07

En

erg

y u

se [k

Wh

]

Flue gas losses wood [kWh]

SH convection wood [kWh]

Flue gas losses stove [kWh]

Store and pipe losses [kWh]

SH radiators + pipes [kWh]

SH convective stove [kWh]

Electricity SH + DHW [kWh]*

DHW [kWh]

Fig. 13: Monthly energy use for the demonstration house. Wood refers to the log wood tiled oven, and stove to the pellet stove. The first six months are before the SCS was installed. For this period store losses are included in the electricity for SH and DHW.

On-site evaluation August 2007 page 14 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Figure 13 shows the monthly energy use. The flue gas losses have been estimated based on data from measurements in the lab. The pellets supply was measured manually by the owner. The store heat losses have been calculated based on an energy balance for the store. The hot water use has been more or less constant during the monitoring period, averaging 8-10 kWh/day, although it is slightly larger in winter. The cold water supply temperature to the house varies from 4 to 16°C over the year. The store heat losses are greater in summer than winter, and increased somewhat after December due to a change in control strategy. Before this date the store was only used for solar. After this date a small volume at the top was also heated by the pellet stove in order to give longer running times for the stove. This results in a greater proportion of heat supplied via the radiators than directly from the stove via convection, as can be seen in figure 13. This proportion is still far below the nominal proportion of 65-85% heat supplied to the water, as measured in laboratory tests.

During August the losses were estimated to be on average 100 W (2.4 kWh/day), although this figure has a relatively high degree of uncertainty as it is calculated from the differences of much larger energy quantities.

Fig. 14: Daily energy values for September 2006.

Figure 14 shows the daily energy values for September 2006. The daily DHW load varied from 5.5 kWh to nearly 15 kWh, but was often around 7 kWh. The solar gain was relatively high for most of the month apart from short periods at the start and end of the month. It was only in these periods that any auxiliary heat was required, and this only after several days with low solar gains. This shows a very good function for the whole system and especially the solar heat store, which has a volume of only 360 litres.

0

2

4

6

8

10

12

14

16

18

20

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Ener

gy

[kW

h]

0

2

4

6

8

10

12

14

16

18

20

Ener

gy

[kW

h]

Solar gains

Auxiliary Heat

DHW

On-site evaluation August 2007 page 15 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Space heating radiators November 2006

0

5

10

15

20

25

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30-8°C

-6°C

-4°C

-2°C

0°C

2°C

4°C

6°C

8°C

10°C

Heat radiators [kWh]Outside temparature [°C]

Fig. 15: Daily energy values for November 2006, solar gains and radiation (upper) and heat delivered from radiators and ambient temperature (lower).

Figure 15 shows the daily solar gains as well as the heat delivered from the radiators. Despite the late period of the year a significant amount of solar gain was achieved, especially at the start of the month. The heat flow delivered by the radiators is small, less than 1 kW average for an ambient temperature of -6°C. This is due to the fact that only a third of the total heat delivered to the house comes from the radiators (see figure 16), the majority is coming directly from the stove. Roughly half of the heat generated by the stove goes is transferred to the water circuit, the rest to the room. This is far less than the nominal value of 80% that is typically determined

Solar gain and irradiation November 2006

0.0

3.5

0.0 0.0 0.0

7.2

5.0

6.76.5

7.0

0.0 0.0

1.0

0.0

5.1

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

4.6

0.0 0.0 0.00

2

4

6

8

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

So

lar

gai

ns

[kW

h]

0

5

10

15

20

25

30

35

40

45

50

To

tal I

rrad

iati

on

[kW

h]

Solar gainsIrradiation on collector

On-site evaluation August 2007 page 16 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

for the stove in the lab under constant operating conditions. A detailed analysis of the data revealed that the running time for the stove was very short due to a relatively small standby storage volume and the settings of the wood pellets stove and main controllers. By connecting the standby store slightly differently and by moving one sensor, a reduced number of starts/stops was achieved, resulting in a higher proportion of heat transferred by the radiators and less by convection/radiation. This can be seen from January 2007 onwards.

Fig. 16: Monthly energy balance (values in kWh) for the system in November 2006

Outlook The demonstration system has been monitored for one full year. Monitoring will carry on for some time to come. Solentek AB and Metro Therm A/S will discuss how to proceed with the further development and commercialisation of the REBUS pellet systems. Relatively little effort is required in terms of development of the system with the separate pellet stove apart from a further analysis and possible changes in the control algorithms for reducing starts/stops. The exact design of the technical unit will also have to be finalised, as there is the possibility of either increasing the standby store, decreasing the height, or using the unused volume as some sort of warm cupboard.

More detailed information on the system and its on-site evaluation is available in /Fur07/ which covers both the compact heating unit (REBUS) with gas and pellets auxiliary heater.

Solar collector

Pellet stove

Elecical heater

Storage unit

Pellet

46

5

606

641 SHdir

302 DHW

321 SHind

34 diff / loss

On-site evaluation August 2007 page 17 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Integrated Collector Storage (ICS, Solior)

Also the approach of an Integrated Collector Storage (ICS) systems had been identified as a promising system concept. This type of concept combines the hot water store and the solar collector in one element.

Fig. 17: Picture of the evaluated ICS (with flat roof support)

Based on this system concept, a product was developed at ECOFYS (figure 17). It consists of a few parts only, many of which are made of polymer material. The essential parts are: A polymer dome which covers a cylindrical tank made of stainless steel and a reflector behind the tank. The system is marketed under the product name Solior. Both a laboratory performance test and several on-site measurements were carried out (/Sch07/). On-site testing includes a long term test on reliability carried out by ECOFYS, one-year monitoring of two systems installed in Spain and eight installed in the Netherlands. As a result of the various tests of the newly developed system, minor changes were made to the system design. Highlights from the testing are:

Performance test An official performance test of a prototype according to the European Standard was performed by INETI in Portugal. This outdoor laboratory test was performed according to the European Standard EN 12976-2

Thermal solar systems and components - Custom built systems - Part 2: Test methods). Table 5 gives some results of the test.

Table 5: Results of the standardised performance test for 140 litre/day hot water demand Location Yield (GJ/a) Yield (kWh/a) Stockholm (global irradiation: 3.9 GJ/a) 3.081 866 Wuerzburg (global irradiation: 3.3 GJ/a) 2.640 733 Davos (global irradiation: 6.0 GJ/a) 4.762 1322

With the improvements made for the production model, a 10% higher yield is expected. This has to be confirmed by another performance test which is currently being carried out (summer 2007).

Demonstration project (on-site tests) Demonstration projects were performed with ten prototype systems. Eight systems were installed in the Netherlands and two in Spain. The project was supported by the EOS-DEMO programme of SenterNovem in the Netherlands. All systems performed well and no repairs were

On-site evaluation August 2007 page 18 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

necessary, only the inner ventilation of the systems was improved during the monitoring year. The hot water demand and the yield of the systems were measured. Figure 18 gives the yield from the monitoring as well as the yield for the systems determined by simulations. For simulations the weather data of the Dutch meteo station the Bilt (2006) was used. On three of the seven systems there was significant shadowing over part of the day. The measured yield shown in figure 18 was corrected to make it comparable with the simulated values. The correction accounts for the differences in irradiation, hot water consumption and shadowing.

-

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

- 20 40 60 80 100 120 140

Hot Water demand [l/day]

Yie

ld [G

J/ye

ar]

Corrected yield

ICS simulation

Fig. 18: Yield over the monitoring year (2006) as a function of the hot water demand as well as the results determined by simulation (for the Netherlands boundary conditions.).

The two systems in Spain were also placed at individual houses. These systems functioned well too. At one of the two sites the occupant even decided to shut off the (natural gas) auxiliary heater from April to October. The heater was switched on again in October because there was a demand for space heating. Apart from this demonstration project there is also a field test running in the Netherlands with a previous prototype. This prototype monitored by ECOFYS is working properly until now. Other standardised tests (of reliability and durability) are running.

On-site evaluation August 2007 page 19 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

System concept with water filled collector loop (AquaSystem)

The promising system concepts with water filled collector loop have been introduced success-fully into the market during the NEGST project. There are two types which serve different applications:

Hot water heating (evaluated in the specific report / Abr06-1/, figure 19).

Water and space heating (combisystem, evaluated in the specific report /Abr06-2/, figures 20 and 21).

Experiences were gained from a large number of systems of both types. Both types were evaluated theoretically which is reported in /Vog06/. The two types of concepts are marketed as AquaSystem .

Fig. 19: Hydraulic scheme of the solar system concept with water filled collector loop for DHW-heating. This system concept has been developed by the German company Paradigma. It is introduced to the German market as AquaSystem.

Fig. 20: Solar combi-system concept with water filled collector loop. In this configu-ration, solar energy is charged into the supply line of the existing heating system.

On-site evaluation August 2007 page 20 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Fig. 21: Solar combisystem concept with water filled collector loop. In this configuration, solar energy is charged into the return line of the existing heating system.

The most important experiences gained from the installation and the operation of the systems are:

the marketing advantage due to retrofit compatibility

the elimination of glycol and its decomposition

the enhancement of the system availability through auto-diagnostics and stringent problem correction.

These findings were derived from the installation and operation of more than 15 000 systems. They are described in more detail in /Abr07/.

On-site evaluation August 2007 page 21 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

Compact heating unit for solar domestic hot water preparation (auroCOMPACT)

The compact heating unit, which serves water and space heating and covers an important part of the energy required for water heating from solar collectors had been evaluated theoretically. The evaluation and the system is described in /Vog06/ and a specific report on the theoretical evaluation of the system concept is given in /Ima06/. This system concept was transferred into a product which was installed in large numbers during the NEGST project. Figure 22 shows the unit. It includes the hot water store, the gas heater, pumps, valves and all control equipment required for space and water heating and the connection of solar collectors.

Fig. 22: The compact heating unit marketed as auroCOMPCT is designed to be placed in the living area. © Vaillant

The most important findings from more than 10 000 systems in operation at the end of the NEGST project are:

the benefits of prefabrication (for easy and safe installation)

the advantage of the aesthetic design (for marketing)

performance and comfort gain through the innovative strategy for hot water preparation with the auxiliary heater

reduced maintenance and improved problem solving through remote surveillance.

These issues are described in more detail in /Ima07/.

On-site evaluation August 2007 page 22 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

DISSEMINATION OF THE RESULTS OF THE ON-SITE EVALUATION

The results of on-site evaluation were presented and discussed at several workshops, con-ferences and congresses. These events are listed in the NEGST deliverable WP1.D4 (/Vog07/). Results were also disseminated by means of the written documents listed below in the section REFERENCES.

REFERENCES

/Vog06/ Vogelsanger, P., C. Wilhelms (2006): WP1.D2 / Report about theoretical system evaluation. (/NEGST/).

/Vog07/ Vogelsanger, P. (2007): WP1.D4 / Design and installation guidelines for the new system generation. (/NEGST/).

/Fur07/ Furbo, S., A. Thür, et al. (2006): Competitive Solar Heating Systems for Residential Buildings (REBUS) Copenhagen, Denmark, DTU: pp. 134. http://www.physics.uio.no/energy/rebus/downloads/REBUS_final_01-2007.pdf

/Thü06/ Thür, A., S. Furbo, et al. (2006): Development of a Compact Solar Combisystem. Eurosun 2006, Glasgow, UK.

/Thü07/ Thür, A. (2007): Compact Solar Combisystem High Efficiency by Minimizing Temperatures, PhD-Thesis, Department of Civil Engineering, Technical University of Denmark, Rapport R-160, ISBN 97-88778-772-343. http://www.aee-intec.at/0uploads/dateien437.pdf

/Wol04/ Wolff, D., P. Teuber, J. Budde, K. Jagnow (2004): Felduntersuchung: Betriebsverhalten von Heizungsanlagen mit Gas-Brennwertkesseln, Fachhochschule Braunschweig Wolfenbüttel, Wolfenbüttel, Germany, http://www.delta-q.de/servlet/PB/show/1024790/bericht%20cd.pdf

/Fie05/ Fiedler, F., C. Bales, et al. (2005): The Actual Status Of The Development Of A Danish/Swedish System Concept For A Solar Combisystem. North Sun 2005, Vilnius, Lithuania.

/Fie07/ Fiedler, F., C. Bales, et. Al. (2007): Monitoring results of two combined pellet and solar heating systems. Abstract accepted to ISES SWC, Beijing, China, Sept. 2007.

/Sch07/ Schaap, A., M.A. Koper (2007): Development of the Solior FL150 solar water heater (presented at ESTEC, Freiburg 2007).

/Abr06-1/ Abrecht S., H. Drück, E. Streicher (2006): WP1.E1 / THEORETICAL EVALUATION OF PROMISING SYSTEM: solar system concept with water filled collector loop for hot water preparation. (/NEGST/).

/Abr06-2/ Abrecht S., H. Drück, E. Streicher (2006): WP1.E2 / THEORETICAL EVALUATION OF PROMISING SYSTEM: solar combisystem concept with water filled collector loop. (/NEGST/).

/Abr07/ Abrecht, S. (2007): WP1.F1 / Experiences from the installation and the operation of the new system generation: solar system concept with water filled collector loop. (/NEGST/).

/Ima07/ Imann, M. (2007): WP1.F2 / Experiences from the installation and the operation of the new system generation: compact heating unit for solar domestic hot water (SDHW) preparation. (/NEGST/).

On-site evaluation August 2007 page 23 of 23 pages

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6

/Ima06/ Imann, M., H. Drück, E. Streicher (2006): WP1.E4 / Theoretical evaluation of promising system: compact heating unit for solar domestic hot water (SDHW) preparation. (/NEGST/).

/NEGST/ New generation of solar systems. Project description and public deliverables: http://www.swt-technologie.de/html/negst.html

Further information is available on Project website: http://www.swt-technologie.de/html/negst.html

ACKNOWLEGDEMENTS

The authors thank Simon Furbo, Frank Fiedler, Bart van der Ree, Stefan Abrecht and Marc Imann for their contributions.

NEGST NEW GENERATION OF SOLAR THERMAL SYSTEMS is a project financed by the European Commission DGTREN within FP6 and the Swiss Federal Office for Education and Science.