evaluation of ist · • ibm still working on citc (current induced thermal cycling), which is...

27
CALCE Electronic Products and Systems Consortium University of Maryland o:\baden\ist\C99-51.ppt C99-51 Evaluation of IST D.B. Barker and M.D. Blattau, Kevin Cluff (Honeywell) Objective: To develop a finite element model to understand interconnect stress testing results and to relate them to oven chamber testing and field usage.

Upload: others

Post on 20-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

C99-51 Evaluation of IST

D.B. Barker and M.D. Blattau,

Kevin Cluff (Honeywell)

Objective: To develop a finite element model to understand interconnectstress testing results and to relate them to oven chamber testing and fieldusage.

Page 2: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

What is IST?

• IST is an acronym for the Interconnect Stress Testing procedure.• Uses current flow to thermally stress the PTH’s within a printed

wiring board assembly.– PTH’s (printed through holes) electrically connect one layer to another.– IST tests the integrity of these interconnects.

• Helps determine whether the printed wiring board assembly canwithstand the rigors of the manufacturing process and end useenvironment.

• Rapid assessment or comparison between various board manufacturersand/or plating.

Page 3: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Terminology Trendsre: IPC Technet Discussions

PTH PTV or PTH/PTV(Plated Through Hole) (Plated Through Via)

Post Separation IL Separation(innerlayer separation)

Page 4: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

IST - History/Background• PCT (Power Cycling Technique) developed by Northern Telecom in 1987• Research into the repeatability and reproducibility of PCT continued in a 1989

joint venture between Northern Telecom and Digital Equipment Corporation.• After poor results/correlations the project is dropped by Northern Telecom and

continued solely by Digital.• New principles are developed at DEC as well as new coupon designs and the

name changed to IST.• In September 1995 a patent is submitted for IST.

– Inventors: Stephen M. Birch, Gerald M. Gavrel, and Zaffer I. Memom– Assignee: Digital Equipment Corporation

• Licensed to PWB Interconnect Solutions, Inc.– Provides complete IST systems– Continues researching various coupon designs– web page: www.pwbcorp.com

• IBM still working on CITC (Current Induced Thermal Cycling), which issimilar to the PCT concept.

Page 5: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

IST vs. PCT

• PCT (Power Cycling Technique)– Uses ohmic heating to heat the holes, interconnects, and surrounding

substrate to a temperature above the boards glass transition temperature.– Cannot distinguish between post separation failures and barrel cracking.– Non-uniform board heating (hot spots).

• IST (Interconnect Stress Testing)– Includes separate post-interconnects and barrel circuit– Uses ohmic heating through the post-interconnects only, to heat the

substrate uniformly.– Continuously monitors resistance changes in both the post-interconnect

circuit and in the barrel test circuit.

Page 6: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

PCT Coupon DesignHeating Current is Passed Through Every PTH

Page 7: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Plated Areas of a 6 Layer IST Test Coupon(Recent Coupon Design from PWB Interconnect Solutions, Inc.)

IST Coupon Design• Distance between holes

0.1”• PWB thickness 60 mils -

93 mils• 6-16 layer PWBs• Plating thickness 0.5 mils -

2 mils• Electroless/Direct

metalization or other• Designer: PWB

Interconnect Solutions, Inc.

Page 8: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

PWB INC L1S

STD06TV1

Sample Detail of Vias and Traces

Page 9: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Example of 6 Layer Layout

Post-Interconnect Testing/Heating Circuit

PTH Interconnect Testing Circuit

Dummy PTH’sRequired for Symmetry

Page 10: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Interconnect Stress TestingCooling Chamber Design andCoupon Layout

Page 11: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Crack

Barrel Failurecircumference cracking of barrel

PWB

PTH

• More common in high aspect ratio holes • Dependent on plating quality

Page 12: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Post Crackingfoil pad-barrel interface cracking (IL - inner layer separation)

Cracks

PWB

PTH

• Separation of barrel from surrounding inner-layer• Corner cracks• Usually found in low aspect ratio holes • Highly dependent on plating quality

Page 13: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

IST Pre Cycling Test SequenceFrom IPC-TM-650

“DC Current Induced Thermal Cycling Test”

• Ambient Resistance: Auto ranging multi-meter measures the ambientresistance of the coupon’s heating circuit.

• Target Temperature Resistance: The system software calculates anddisplays the required “target” resistance (temperature).

• Rejection Resistance: The rejection resistance is calculated and displayed.This is added to the target resistance to establish the rejection criteria.

• Current: The system selects an initial current based on the ambientresistance of the coupon. During pre-cycling the initial current is adjustedso that the target resistance (temperature) is achieved in 3 minutes.

• Pre-cycling initiated by application of initial current. The system thenchecks the resistance after 3 minutes to see if the target resistance isachieved. If not the system adjusts the current and pre-cycles the couponagain.

Page 14: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

IST Stress Cycle Test Sequence From IPC-TM-650

“DC Current Induced Thermal Cycling Test”

• Initiation of stress test by applying current determined by pre-cycling for threeminutes. After three minutes the coupon is cooled for 2-3 minutes dependingon the thickness.

• Coupons are repeatedly cycled until one of the rejection criteria are achievedor the maximum number of cycles is completed.

• The coupon’s resistance increases as failure inception occurs. The rate ofchange in the resistance is analogous to the degree of mechanical failure.

• When the coupon’s resistance exceeds the rejection resistance the IST stresstesting is stopped. This rejection criteria prevents thermal runaway.

• The IST systems continuously monitors at multiple points in both circuits ofeach coupon and records the data.

Page 15: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Example of Resulting Data Analysis

Post interconnection failure that starts to occur at 70 cycles whilethe barrel doesn’t show signs of failure until 250 cycles.

PWB Interconnect Solutions, Inc.

Page 16: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Axisymmetric Electro-Thermal FEA of IST Coupon(Current is equivalent to 9 Amps in Barrel Between Layers 2 and 3)

Layer 2

Layer 3

9 Amps

Page 17: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

PWB INC L1S

STD06TV1

Section Taken for 3-D FEM (Current Induced Heating Phase & Forced Convection Cooling Phase)

Area used in 3-D FEM

Page 18: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

0.0135” Diameter PTH0.045” Diameter PTH

0.02” Copper Trace

Temperatures After 3 Minutes Heating, 6 Layer PWB

PWB

Barrel TestPTH

Heat/PostPTH

Page 19: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Temperature Gradients After 2 Minutes of Forced Air Cooling

Air Flow

Page 20: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

0 50 100 150 200 250 300

Time (seconds)

Tem

per

atu

re (

°C)

Post/HeatPWBBarrel

Temperature Cycle Profile3 Minutes Heating 2 Minutes Cooling

IST TEMPERATURE CYCLEBetween 25°C and 150°C

020406080

100120140160

0 200 400 600 800 1000

TIME (Seconds)

TE

MP

ER

AT

UR

E (

°C)

Page 21: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Conclusions From FEA

• Axisymmetric model is inadequate– more current required to heat the board using only vias– heating is primarily due to current in traces

• Board heating is thorough with small temperature gradients.• Temperature increase is linear during heating phase.

Page 22: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Delphi Delco IST vs Oven Cycling Test*(samples from same panel)

• IST test temperature ranges (3 minutes heating and 2 minutes cooling per cycle)

· 25°C to 150°C· 25°C to 170°C· 25°C to 190°C

• Oven test temperature ranges (Dwell time of 20 minutes at each extreme) (50 minutes per cycle)

· -40°C to 125°C· -40°C to 145°C· -40°C to 165°C

* Available for download on web

Page 23: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Delphi Delco IST Failure DataNOTE: Data analyzed and presented wrt Tmax not ∆T

IST Failure Data on Weibull Probability Paper

Time-to-Fail t

Per

cent

Fai

lure

log(

log(

100/

(100

-Per

cent

Fai

lure

)))

-5

-4

-3

-2

-1

0

1

2

1.

5.

10.10.

20.

30.

40.50.60.70.80.90.95.

99.

99.9

200.400.

600.800.

1000.1200.

1400.1600.

1800.

150oC

170oC190oC

Page 24: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Delphi Delco Oven Cycling Failure DataNOTE: Data analyzed and presented wrt Tmax not ∆T

Thermal Oven Failure Data on Weibull Probability Paper

Time-to-Fail t

Per

cent

Fai

lure

log(

log(

100/

(100

-Per

cent

Fai

lure

)))

-5

-4

-3

-2

-1

0

1

2

1.

5.

10.10.

20.

30.

40.50.60.70.80.

90.95.

99.

99.9

200. 400. 600. 800. 1000. 1500 2000

150oC

170oC190oC

Page 25: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

y = 9.2003x - 9.0579@ AF = 1 DT_oven/DT_IST = 1.093

0

0.5

1

1.5

2

2.5

3

3.5

4

1 1.05 1.1 1.15 1.2 1.25 1.3 1.35

Ratio of DT_oven/DT_IST

Acc

eler

atio

n Fa

ctor

New Interpretation of Delphi Delco Data(temperatures expressed in terms of ∆T)

y = 9.2003x - 9.0579

0

2

4

6

8

10

12

14

16

18

20

1 1.1 1.2 1.3 1.4 1.5 1.6 1.7

Ratio of DT_oven/DT_IST

Acc

eler

atio

n Fa

ctor

For AF=1 (same number of cycles to failure), oven cycling requires 1.1 times higher ∆T,i.e. IST test is slightly more severe.

AF= NIST / Noven

Page 26: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

Work Accomplished– FEA model of IST coupon– IST thermal transients and gradients not significant– Preliminary Analysis of correlation data between IST and oven

cycling imply that CALCE PTH model can be easily used topredict both IST test and field life using ∆T.

Work Remaining– Locate additional IST and oven data for correlation studies– Additional correlation studies using the CALCE PTH model with

IST and oven cycling data– Investigate resin rich areas and correlation with IL separation

using FEA

Page 27: Evaluation of IST · • IBM still working on CITC (Current Induced Thermal Cycling), which is similar to the PCT concept. CALCE Electronic Products and Systems Consortium University

CALCE Electronic Products and Systems Consortium University of Marylando:\baden\ist\C99-51.ppt

PTV Interconnect Reliability Concerns(in hierarchical order)

• Thermal Cycle - (CALCE)• Copper plating thickness/quality, (uniformity, ductility, elongation,

tensile strength).• Material Tg, CTE, board thickness, hole diameter, number of layers

(glass to resin ratio).• Surface finish, PTH metallization, foil thickness, construction, grid

size).• Design (pads Vs no pads, annular ring, anti-pad clearance).

RE: Bill Birch, PWB Interconnect Solutions Inc.(from personal and IPC Technet discussions)