eucard wp 7 – high field magnets task 7.2 – support study status report eucard wp 7 – high...
TRANSCRIPT
![Page 1: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/1.jpg)
EuCARD WP 7 – High Field MagnetsEuCARD WP 7 – High Field Magnets Task 2 – Support studies
Task 7.2 – Task 7.2 – Support StudySupport Study Status reportStatus report
EuCARD WP7 Collaboration Meeting – 18.09.2012 INFN-LASA Milano
Maciej Chorowski, Jaroslaw Polinski, Piotr Bogdan
Faculty of Mechanical and Power Engineering
![Page 2: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/2.jpg)
2
Outline
• Sample irradiation• Cryostat for electrical test• Mechanical tests• Thermal test at PWR• Task 7.2 planning
![Page 3: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/3.jpg)
3
Material burning during the irradiation
![Page 4: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/4.jpg)
4
Material burning during the irradiation
Pt 1000 sensor
1st possible reason: Lack of LN2 during irradiation?
The samples holder is equipped with Pt1000 T sensor. In case of temperature exceed 80K the accelerator control system stops the accelerator
![Page 5: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/5.jpg)
5
Material burning during the irradiation
2nd possible reason:
Heat deposited in the irradiated sample creates LN2 vapor bubbles around the heated area. Due of that the cooling capacity of the coolant drastically decrease and temperature of the sample increase over the material melting or flash point
Decision: reduction of the dose rate by 1/2 and see if the material is still burning for 50MGy of total dose
Beam
LN2
LN2 vapors
Irradiated sample
![Page 6: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/6.jpg)
6
Methods of the dose rate reduction
4s
6,67 ms
N electrons/s
4s
13,33 ms
2s
6,67 ms
N electrons/s
N electrons/s
4s
6,67 ms
1/2N electrons/s
Original beam scheme
Decrease of impulse frequency
Decrease of impulse time
Decrease of impulse intensity
![Page 7: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/7.jpg)
7
Material burning during the irradiation
Mix 71
Mix 237
LARP
Lonza CE
1st package – irradiated with 16 kGy/min 2nd package – irradiated with 10.8 kGy/min
![Page 8: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/8.jpg)
8
Irradiation plan prediction (based on the present irradiation procedure knowledge)
End
of
EuC
AR
D
![Page 9: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/9.jpg)
9
Toward to complete the irradiation certification program in the EuCARD time frame
• Determination/confirmation of the maximum dose rate which not cause the sample burning
• Change of thermal properties test method – thermal conductivity and heat capacity in 4-300K temperature range can
be determined on very small material sample by Institute of Low Temperature and Structure Research (ILTSR) in Wroclaw
– the samples for this tests can be extracted from the electrical or mechanical samples after them tests
– preparation of separated samples for the thermal tests, irradiated with 1 spot, can be considered
• Change of number of the irradiation spots on the mechanical samples from 4 to 1
![Page 10: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/10.jpg)
10
Patterns for thermal samples - 4 spots, d=17.5 mm
![Page 11: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/11.jpg)
11
Preliminary mechanical testsMech. sample preparation
![Page 12: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/12.jpg)
12
Preliminary mechanical testsMech. tests – irradiated samples
Burned Normal (Total dose: 0.5 – 0.7 MGy)
![Page 13: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/13.jpg)
13
Outline
• Sample irradiation• Cryostat for electrical test• Mechanical tests• Thermal test at PWR• Task 7.2 planning
![Page 14: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/14.jpg)
14
Electrical certification test cryostat
Voltage source – up to 60kV
![Page 15: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/15.jpg)
15
Electrical certification test cryostat stsus
• Cryostat was delivered at the end of August 2012
• Instrumentation - ongoing
• Commissioning, determination of the test procedure and first tests – mid. of Oct. 2012
![Page 16: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/16.jpg)
16
Outline
• Sample irradiation• Cryostat for electrical test• Mechanical tests• Thermal test at PWR• Task 7.2 planning
![Page 17: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/17.jpg)
17
Mechanical tests status
• Update of existing mechanical set-up with elements allow measurements in LN2 is undergoing in collaboration with PWR MechLab
• The possibility and quality of the mechanical sample cut-off with WaterJet technique will be tested next weeks
• The PWR MechLab has possibility to test the sample with Fourier Transform Infrared Spectroscopy (FTIS) and with Thermal Gravimetric Analysis (TGA), what can provide more information about the samples destruction origin (thermal/radiation)
![Page 18: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/18.jpg)
18
Outline
• Sample irradiation• Cryostat for electrical test• Mechanical tests• Thermal test at PWR• Task 7.2 planning
![Page 19: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/19.jpg)
19
Thermal tests – test parameters
• Material: unirradiated Mix 71 (NED insulation)• Thicknesses: 145.4 m, 253.7 m, 368.2 m, 501.8 m• Bath temperature levels: 1.5K, 1.55K, 1.6K. 1.7K, 1.8K,
1.9K, 2.0K, 2.1K• Dissipated heat range: 0÷125mW/sample = 0÷12 W/m2
• Heat step: 2mW• Heat step time: min. 4 min• Temperature increase range considered in post-test
analysis: 10÷35mK • Bath temperature stabilization: ±0.25mK
![Page 20: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/20.jpg)
20
Thermal tests – set-up view
![Page 21: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/21.jpg)
21
Thermal tests – test resultsThermal conductivity
0,02
0,025
0,03
0,035
0,04
0,045
1,5 1,6 1,7 1,8 1,9 2 2,1 2,2
Temperature
Th
erm
al c
on
du
ctiv
ity,
W/m
K
Meas 2012
NED equ.
![Page 22: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/22.jpg)
22
Thermal tests – test resultsKapitza resistance
0
0,0001
0,0002
0,0003
0,0004
0,0005
0,0006
0,0007
0,0008
1,5 1,6 1,7 1,8 1,9 2 2,1 2,2
Temperature
Kap
itza
Res
ista
nce
, m2K
/W
Meas 2012
NED equ.
![Page 23: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/23.jpg)
23
Outline
• Sample irradiation• Cryostat for electrical test• Mechanical tests• Thermal test at PWR• Task 7.2 planning
![Page 24: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/24.jpg)
24
WP7.2 Plan
![Page 25: EuCARD WP 7 – High Field Magnets Task 7.2 – Support Study Status report EuCARD WP 7 – High Field Magnets Task 2 – Support studies Task 7.2 – Support Study](https://reader035.vdocuments.us/reader035/viewer/2022062718/56649e9f5503460f94ba1ca9/html5/thumbnails/25.jpg)
25
Summary
• The sample burning during irradiation has been found• Decrease of the irradiation dose rate from 16.0 to 10.8
kGy/min avoided this problem, nevertheless the max allowed dose rate need to be found/confirmed
• To keep the EuCARD time scale the modification in the thermal property certification test as well as in the mechanical and the thermal sample irradiation pattern is proposed
• Cryostat for electrical certification tests has been delivered and is currently under instrumentation on PWr. First certification tests are foreseen for mid of Oct.
• Preparation of the mechanical certification test in the LN2 conditions is ongoing
• Thermal conductivity and Kapitza resistance values of Mix 71 (NED) insulation has been confirmed on the PWr HEII cryostat experiment