Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. The client should not use it to claim product endorsement by A2LA or any government agencies. The test results in the report only apply to the tested sample
Rev.01 Page 1 of 16
ETSI EN 300 440-2 V1.4.1 TEST REPORT
For Product Name : WCDMA ANDROID SMART PHONE
Brand Name : thl Model No. : T5
Series Model : N/A Test Report Number : C131213R01-RT2
Issued for
SHENZHEN HONGJIAYUAN COMMUNICATION TECHNOLOGY CO.,LTD Rm2406, Block A of Electronic & Technology Building, 2070, Shenzhen Middle Road, Shenzhen
518000 P.R. China
Issued by
Compliance Certification Services Inc.
Kun shan Laboratory
No.10 Weiye Rd., Innovation park, Eco&Tec, Development Zone, Kunshan City, Jiangsu, China
TEL: 86-512-57355888
FAX: 86-512-57370818
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 2 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
TABLE OF CONTENTS
Revision History ................................................................................................................................... 3 1 TEST RESULT CERTIFICATION ................................................................................................. 4 2 EUT DESCRIPTION...................................................................................................................... 5 3 TEST METHODOLOGY ................................................................................................................ 6
3.1. GENERAL DESCRIPTION OF APPLIED STANDARDS ................................................... 6 3.2. DESCRIPTION OF TEST MODES .................................................................................... 6 3.3. SETUP OF EQUIPMENT UNDER TEST ........................................................................... 6
4 FACILITIES AND ACCREDITATIONS ......................................................................................... 7 4.1. FACILITIES ........................................................................................................................ 7 4.2. ACCREDITATIONS ........................................................................................................... 7 4.3. MEASUREMENT UNCERTAINTY ..................................................................................... 7 4.4. LIST OF MEASURING EQUIPMENT ................................................................................ 8
5 ETSI EN 300 440-1/-2 REQUIREMENTS ..................................................................................... 9 5.1. EQUIVALENT ISOTROPICALLY RADIATED POWER (EIRP) .......................................... 9 5.2. PERMITTED RANGE OF OPERATING FREQUENCIES ................................................ 11 5.3. TRANSIMITTER SPURIOUS EMISSIONS ...................................................................... 12 5.4. DUTY CYCLE .................................................................................................................. 14 5.5. RECEIVER SPURIOUS EMISSIONS .............................................................................. 15
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 3 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Revision History Rev. Issue Date Revisions Effect Page Revised By 00 December 23, 2013 Initial Issue ALL Jeff Fang
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 4 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
1 TEST RESULT CERTIFICATION Product Name: WCDMA ANDROID SMART PHONE
Brand Name: thl
Model Name: T5
Series Model: N/A
Application Discrepancy:
N/A
Device Category: Production unit
Applicant: Address:
SHENZHEN HONGJIAYUAN COMMUNICATION TECHNOLOGY CO.,LTD Rm2406, Block A of Electronic & Technology Building, 2070, Shenzhen
Middle Road, Shenzhen 518000 P.R. China
Manufacturer: Address:
SHENZHEN HONGJIAYUAN COMMUNICATION TECHNOLOGY CO.,LTD Rm2406, Block A of Electronic & Technology Building, 2070, Shenzhen
Middle Road, Shenzhen 518000 P.R. China
Date of test: December 19, 2013
Test Result : Conform
APPLICABLE STANDARDS
Standard TEST RESULT
ETSI EN 300 440 -2(V1.4.1: 2010-08) No non-compliance noted
The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in ETSI EN 300 440-2. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties.
Jeff.Fang RF Manager Compliance Certification Services Inc.
Blent.Wang Test Engineer Compliance Certification Services Inc.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 5 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
2 EUT DESCRIPTION Product Name: WCDMA ANDROID SMART PHONE
Brand Name: thl
Model Name: T5 Series Model: N/A
Model Discrepancy: N/A
Power Adapter Power Rating :
Power supply and ADP(rating): Model: UT-059E-698 INPUT: AC100-240V 50/60Hz 0.15A OUTPUT: DC 5V 500mA Battery(rating): Capacitance: 1950mAh 3.8V
Frequency Range: 1575.42 MHz
Number of Channels: 1 Channels
Temperature Range: -15 ~ 55°C
Remark: for more details, please refer to the User’s manual of the EUT.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 6 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
3 TEST METHODOLOGY 3.1. GENERAL DESCRIPTION OF APPLIED STANDARDS
According to its specifications, the EUT must comply with the requirements of the following standards:
ETSI EN 300 440-1: "Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 1: Technical characteristics and test methods".
CEPT/ERC Recommendation 70-03 (2007): "Relating to the use of Short Range Devices (SRD)".
ETSI EN 300 440-2: Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).
3.2. DESCRIPTION OF TEST MODES
The EUT had been tested under the operating condition.
Software used to control the EUT for staying in receiving mode is programmed. After the preliminary scan, the following test mode was found to produce the highest emission level.
Mode1: Receive Mode
3.3. SETUP OF EQUIPMENT UNDER TEST 3.3.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit along with the following necessary accessories or support units, which are adopted to form a representative test configuration.
No. Equipment Model No. Serial No. FCC ID Trade Name Data Cable Power Cord
1 N/A N/A N/A N/A N/A N/A N/A
Notes: 1) All the equipment/cables were placed in the worst-case configuration to maximize the emission
during the test. 2) Grounding was established in accordance with the manufacturer’s requirements and conditions for
the intended use.
3.3.2. CONFIGURATION OF SYSTEM UNDER TEST
See test photographs attached in Appendix I for the actual connections between EUT and support equipment.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 7 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
4 FACILITIES AND ACCREDITATIONS 4.1. FACILITIES All measurement facilities used to collect the measurement data are located at
No.10 Weiye Rd, Innovation park, Eco&Tec, Development Zone, Kunshan City, Jiangsu, China
The sites are constructed in conformance with the requirements of ANSI C63.4 and CISPR Publication
22. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus
and Measurement Methods.”
4.2. ACCREDITATIONS Our laboratories are accredited and approved by the following accreditation body according to ISO/IEC 17025.
USA A2LA China CNAS
The measuring facility of laboratories has been authorized or registered by the following approval agencies.
Canada Industry Canada Japan VCCI Taiwan BSMI USA FCC
Copies of granted accreditation certificates are available for downloading from our web site,
http://www.ccsrf.com
4.3. MEASUREMENT UNCERTAINTY
For the test methods, according to the present document (ETSI EN 300 440) the uncertainty figures shall
be calculated according to the methods described in the ETR 028 [4] and shall correspond to an
expansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95
% and 95,45 % in case where the distributions characterizing the actual measurement uncertainties are
normal (Gaussian)).
Table 3 is based on such expansion factors.
Table 3: Measurement uncertainty Parameter Uncertainty
Frequency +/-1 * 10-7
RF power, conducted +0.28dB/- 0.30 dB
Adjacent channel power +/- 1 dB
Conducted emission of transmitter, valid up to valid up to 12.75 GHz +1.2/- 1.1 dB
Conducted emission of receivers +1.2/- 1.1 dB
Radiated emission of transmitter, valid up to12.75 GHz +/- 3.84 dB Radiated emission of receiver, valid up to12.75 GH +/- 3.84 dB
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 8 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
4.4. LIST OF MEASURING EQUIPMENT Name of
Equipment Manufacturer Model Serial Number Calibration Due Remark
Spectrum
Analyzer Agilent E4446A MY44020154 2014-04-16 Conducted
Signal Generator Agilent E8257C MY43321570 2014-05-05 Radiation
Pre-Amplifier CCSRF AMP1277 SN:001 2014-11-06 Radiation
Pre-Amplifier Miteq AMF-6F-260400-40-8P 1037496 2014-04-26 Radiation
Bilog Antenna Sunol JB1 A110204-1 2014-05-02 Radiation
Horn-antenna Schwarzbeck BBHA9120D D:267 2014-04-28 Radiation
Horn Antenna Schwarzbeck BBHA9170 BBHA9170171 2014-5-11 Radiation
Oscilloscope Agilent DSO6104A MY44002585 2014-3-24 Conducted
AC Power
Source EXTECH 6605 1570106 N.C.R
Conducted
DC Power
Supply AGILENT E3632A MY50340053 N.C.R
Conducted
Power Sensor Agilent E9327A US40441788 2014-03-14 Conducted
Power Meter Agilent E4416A QB41292714 2014-04-16 Conducted
Bluetooth Tester R&S CBT 100189 N.C.R Conducted
Detector
Negative Agilent 8473B MY42240176 2014-5-12 Conducted
BIAS-TEE Mini-Circuits ZFBT-6G RF092100430 2014-5-12 Conducted
Notes: 1. Each of the above test instruments is calibrated every 12 months and the calibration is traceable to
NML/ROC and NIST/USA.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 9 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
5 ETSI EN 300 440-1/-2 REQUIREMENTS 5.1. EQUIVALENT ISOTROPICALLY RADIATED POWER (EIRP)
DEFINITION
ETSI EN 300 440-1 clause 7.1 The eirp is defined as the peak power of the transmitter and calculated according to the procedure given
in the following clause. See clause 5 for the test conditions.
LIMIT ETSI EN 300 440-1 clause 7.1.3 The effective radiated power shall not exceeded the power class value given in the following this table:
Power Class (Remark 1) Power level (Conducted or radiated)
*8 *10 mW
9 25 mW
11 100 mW
12 500mW (see Remark 2)
13 1 W
14 2 W
14a 4W (see Remark 2) Remark 1: Class designation is based on CEPT/ERC Recommendation 70-03 [1]. Remark 2: For RFID applications, see annex C of the present document.
For equipment with an integral antenna and no RF connector, measurements under extreme conditions
are not required.
Test Configuration
Below 1GHz
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 10 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Above 1GHz
Substituted Method Test Set-up
For the in situ test setup, refer to “Photographs of the Test Configuration.”
TEST PROCEDURE
1. Please refer to ETSI EN 300 440-1 clause 5 for the test conditions, power sources and ambient.
2. Please refer to ETSI EN 300 440-1 clause 7.1.2 for the measurement method.
TEST RESULTS
Since the EUT is a RX unit, no test was done.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 11 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
5.2. PERMITTED RANGE OF OPERATING FREQUENCIES
DEFINITION
ETSI EN 300 440-1 clause 7.2.1 The permitted range of operating frequencies includes all frequencies on which the equipment may operate within an assigned frequency band. The operating frequency range shall be declared by the manufacturer.
The range of frequencies, determined by clause 7.2, shall be specified in the test report.
LIMIT ETSI EN 300 440-1 clause 7.2.4 The width of the power envelope is fH -fL for a given operating frequency. In equipment that allows adjustment or selection of different operating frequencies, the power envelope takes up different positions in the allowed band. The frequency range is determined by the lowest value of f L and the highest value of fH resulting from the adjustment of the equipment to the lowest and highest operating frequencies. For all equipment the frequency range shall lie within the frequency band allocated for use as recommended in CEPT/ERC Recommendation 70-03 [1] and ERC Decisions. For non-harmonized frequency bands the available frequency range may differ between national administrations.
Test Configuration
Temperature and Voltage Measurement (under normal and extreme test conditions)
TEST PROCEDURE TEST PROCEDURE 1. Please refer to ETSI EN 300 440-1 clause 5 for the test conditions, power sources and
ambient. 2. Please refer to ETSI EN 300 440-1 clause 7.2.2 for the method of measurement and clause 7.2.3 for
the Method of measurement for equipment using FHSS modulation.
TEST RESULTS Since the EUT is a RX unit, no test was done.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 12 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
5.3. TRANSIMITTER SPURIOUS EMISSIONS
DEFINITION ETSI EN 300 440-1 clause 7.3.1 Spurious emissions are emissions at frequencies, other than those of the carrier and sidebands
associated with normal modulation. The level of spurious emissions shall be measured as either:
a)
i) their power level in a specified load (conducted emission); and
ii) their effective radiated power when radiated by the cabinet and structure of the equipment (cabinet
radiation);
b) their effective radiated power when radiated by the cabinet and the integral or dedicated antenna, in
the case of equipment fitted with such an antenna and no permanent RF connector.
LIMIT The power of any spurious emission shall not exceed the following values given in table:
Radiated spurious emissions
State
47 MHz to 74 MHz 87.5 MHz to 118 MHz174 MHz to 230 MHz 470 MHz to 862 MHz
Other frequencies 1000 MHz≦
Frequencies > 1000 MHz
Operating 4 nW
-54dBm 250 nW -36 dBm
1 µW -30dBm
Standby 2 nW -57dBm
2 nW -57dBm
20 nW -47dBm
Test Configuration
Below 1GHz
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 13 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Above 1GHz
Substituted Method Test Set-up
For the in situ test setup, refer to “Photographs of the Test Configuration.”
TEST PROCEDURE 1. Please refer to ETSI EN 300 440-1 clause 6 for the test conditions. 2. Please refer to ETSI EN 300 440-1 clause 7.3.2 / 7.3.3 / 7.3.4 / 7.3.5for the measurement method.
TEST RESULTS Since the EUT is a RX unit, no test was done.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 14 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
5.4. DUTY CYCLE
LIMIT ETSI EN 300 440-1 clause 7.4.1 For the purpose of the present document the term duty cycle refers to the ratio of the total on time of the "message" to the total off-time in any one hour period. The device may be triggered either automatically or manually and depending on how the device is triggered will also depend on whether the duty cycle is fixed or random.In a period of 1 hour the duty cycle shall not exceed the class values given below:.
Duty cycle class Duty cycle ratio
1 (%)
2 <0.1%
*3 <1.0%
4 *<10%
TEST PROCEDURE Please refer to ETSI EN 300 440-1 Subclause 6 for the test conditions.
TEST RESULTS Since the EUT is a RX unit, no test was done.
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 15 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
5.5. RECEIVER SPURIOUS EMISSIONS
LIMIT ETSI EN 300 440-1 clause 8.4.5 The power of any spurious emission shall not exceed 2 nW in the range 25 MHz to 1 GHz and shall not exceed 20 nW on frequencies above 1 GHz.
Mode 25 MHz - 1 GHz Above 1 GHz
Operating 2 nW -57dBm
20nW -47dBm
Remark: The limits are applicable to all receiver classes.
TEST INSTRUMENTS
(Same as section 5.3 in this test report)
Test Configuration
Conducted Spurious Emissions:
(Same as section 5.3 in this test report)
Radiated Spurious Emissions:
(Same as section 5.3 in this test report)
TEST PROCEDURE 1. Please refer to ETSI EN 300 440-1 clause 6 for the test conditions. 2. Please refer to ETSI EN 300 440-1 clause 8.4.2 / 8.4.3 / 8.4.4 for the measurement method.
TEST RESULTS No non-compliance noted
Compliance Certification Services Inc. Date of Issue: December 23, 2013 Report No .: C131213R01-RT2
Page 16 of 16 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Below 1GHz
EUT Mode : RX / GPS Mode Temperature: 20℃
Description: Continuous Receive Relative Humidity : 45~48%
Test By: Lily.Wang Test Date: 2013-12-19
Frequency Reading level Antenna Correction Factor Emission level Limit Margin(MHz) (dBm) Polarization (dB) (dBm) (dBm) (dB)
149.7955 -75.96 V -11.34 -87.30 -57.00 -30.30409.3449 -76.63 V -7.35 -83.98 -57.00 -26.98477.7923 -76.96 V -5.97 -82.93 -57.00 -25.93533.6629 -76.41 V -5.53 -81.94 -57.00 -24.94675.1369 -76.56 V -3.18 -79.74 -57.00 -22.74936.3269 -76.55 V -0.49 -77.04 -57.00 -20.04
129.5624 -76.85 H -8.11 -84.96 -57.00 -27.96269.3928 -76.96 H -10.13 -87.09 -57.00 -30.09317.5839 -75.84 H -9.82 -85.66 -57.00 -28.66549.2987 -76.69 H -5.22 -81.91 -57.00 -24.91699.9637 -76.55 H -2.80 -79.35 -57.00 -22.35874.1287 -76.63 H -1.09 -77.72 -57.00 -20.72
Remark: 1. The emission behaviour belongs to narrowband spurious emission. 2. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with “ N/A ” remark, if no
specific emissions from the EUT are recorded (ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor.
Above 1GHz EUT Mode : RX / GPS Mode Temperature: 20℃
Description: Continuous Receive Relative Humidity : 45~48%
Test By: Lily.Wang Test Date: 2013-12-19
FrequencyReading level Antenna Correction Factor Emission level Limit Margin(MHz) (dBm) Polarization (dB) (dBm) (dBm) (dB)
2177.961 -62.53 V 2.15 -60.38 -47.00 -13.38
3096.754 -60.96 H 4.59 -56.37 -47.00 -9.37 Remark: 1. The emission behaviour belongs to narrowband spurious emission. 2. Measurements above show only up to maximum emissions noted, if no specific emissions from the EUT are
recorded (ie: margin>20dB from the applicable limit) and considered that's already beyond the background noise floor.
END OF REPORT