Page 1: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

EternityQuick Start

Page 2: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB
Page 3: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

EternityEternityEternityEternityEternity

Integrated Enterprise Voice Switchwith Universal Connectivity

Quick Start

Page 4: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

IntroductionThank you for choosing the Matrix Eternity! Please read the instructions in this

quick start to install this feature reached System.

This Quick Start is meant to help you install the basic features and parameters

of the system. For advanced installation and detailed feature description,

please refer the Eternity System Manual provided to you on the CD-ROM.

It is possible to configure the Eternity using following interfaces:

Web interface (TCP/IP)

Telephonic interface (using SLT and DKP)

Serial Interface (RS-232)

Compared to the telephonic and serial interface, the Web interface is simpler

and more user friendly. Hence, we recommend the system engineer to use the

web interface to configure the Eternity.

* This Quick Start is applicable for software version V6R13 onwards.

Before You Start

Verify Package ContentUnpack the system. Make sure that your package contains all the below items.

If any item is missing or damaged, please contact the source from where you

have purchased the system.

Wall mounting nails

Mounting Template

MDF cable for Switch Card (provided with Eternity ME only)

Telephone Personality Guide

Matrix Logos

Eternity Platform 3 Pin AC Mains cable

CD containing Voice Messages, System Manual, Quick Start and User Card.

Quick Start and User Card

Support Card

Warranty Card

RJ-45 Cable

Page 5: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Installing the Eternity

Precautions Ensure proper electrical earth and telecom earth for safety of personnel as

well as of the System.

Always wear properly earthed anti static belts while handling the cards of

the System.

Use Primary Protection on the trunk and long distance extension lines to

protect the system from lightning and electrical surges.

It is advisable that the system should be installed away from any source of

electromagnetic noise such as any radio equipment, heavy transformers,

faulty electric chokes of tube-lights, any device having a faulty coil etc. This

will reduce any problem arising due to electromagnetic effect.

InstallationInstalling SLT, DKP and TWT Cards:

Unpack the SLT, TWT, DKP cards and insert them in the universal slots of

the Eternity.

Plug the MDF cable provided with each card in the MDF connector provided

on the front panel of the card.

Refer the cable connections given in the 'Appendix' to identify the ports and

terminate the open end of the cables in the main MDF.

Single Line Analog Telephone instruments can be connected to SLT port,

Digital Key phones viz. Eon45, Eon48, Eon42 and consoles viz. DSS64,

DSS72 and DSS16X4 can be connected to the DKP Port.

Two Wire Trunk (Analog Trunk) can be connected to TWT port.

Installing the BRI Card:

Refer below given information before inserting the BRI card in the system.

While installing the BRI Card in the Eternity ME

Use the MDF cable provided with the BRI card.

When the BRI port is to be used in the NT mode the Tx and Rx cable of BRI

port shall be crossed with Rx and Tx cables of the terminal respectively.

For using the BRI port in the TE mode, the cable connections shall need not

to be crossed.

While installing the BRI Card in the Eternity GE

While installing BRI card in the Eternity GE, you shall also set the Jumpers

given on the BRI Card as shown below to use them as NT/TE.

By default, all BRI ports are configured in TE Mode.

J1 J2 J3 J4 J6 J7 J8 J9

NT BC BC BC BC BC BC BC BC

TE AB AB AB AB AB AB AB AB

Jumper Position for Port1 Jumper Position for Port2Mode

Page 6: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

J10 J16 J17 J18 J14 J15 J19 J20

NT BC BC BC BC BC BC BC BC

TE AB AB AB AB AB AB AB AB

Jumper Position for Port3 Jumper Position for Port4Mode

Above jumpers are on the Main Board.

Common points for installing the BRI card in Eternity-ME and GE

Depending on the requirement, each BRI Port can be configured in TE/NT

mode. It is possible to feed power to the terminal equipments connected to

the BRI port (Orientation type configured as Network) from the Eternity.

To feed the power on Tx and Rx wires, set the jumpers J1 and J2 of BRI

module in AB position.

To feed the power on separate pairs of wires, set the jumpers J1 and J2 of

BRI module in BC position.

To power the ISDN terminal from external power source, keep the jumpers

J1 and J2 open.

The jumpers J1 and J2 as are provided on the BRI module (daughter

board).

Number of ISDN terminals that can be connected on the BRI port

configured in NT mode depends on the power consumed by the ISDN

terminals. Maximum power that can be provided on one BRI port is 50mA.

However, from signaling point of view max 8 terminals can be connected

on the BRI port configured in NT mode. Hence, if the terminal equipments

do not consume power from the BRI port (configured in NT mode) of the

Eternity, maximum 8 terminals can be connected to it

Termination Resistance on the BRI PortTermination of 100 Ohms should be inserted in following cases:

1. When the BRI port is configured in NT mode.

2. When the BRI port is configured in TE mode and connected in Point-to-

Point configuration as shown in figure1.

Figure 1:

Eternity

NT

BRILineISDN

Network

TE

Page 7: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

3. When the BRI port is configured in TE mode and connected as last

terminal on the S0 bus (Multi-point configuration) as shown in figure 2.

Figure 2:

NT

BRILineISDN

Network

Eternity

Other ISDN

Equipment

Other ISDN

Equipment

TETETE

4. Termination need not be inserted in case 2 and 3 above, if the S0 bus

itself supports Terminating resistors.

5. Termination need not be inserted if BRI port of Eternity (configured in TE

mode) is connected as any terminal other than the last terminal on the S0

bus (Multi-point configuration).

To set the 100 Ω termination on the BRI port set the Jumpers J3 and J4

(provided on the BRI module) in AB position.

To remove the 100 Ω termination from the BRI port set the Jumpers J3

and J4 (provided on the BRI module) in BC position.

While Installing E&M Card

The E&M Card supports Type-4 and Type-5 connection.

To select the Type-4 connection for the E&M Port, set Jumpers J1 and J2

(given on E&M module) in AB Position.

To select the Type-5 connection for the E&M Port, set Jumpers J1 and J2

(given on E&M module) in BC Position.

By default, all the E&M Ports are set to support Type-4 connection.

The E&M port can be set for the 2-wire speech interface or 4 wire speech

interface as required.

To select 2-wire speech interface for the E&M Port, set Jumpers J3 and J4

(given on E&M module) in BC Position.

To select 4-wire speech interface for the E&M Port, set Jumpers J3 and J4

(given on E&M module) in AB Position.

While Installing GSM (Mobile) Card

Unpack the Mobile Card.

Connect the antenna (provided with the Mobile card) to the splitter

connector provided on the front panel of the Mobile card.

Page 8: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Following figure shows location of Mobile port in Mobile card.

Eternity GE GSM 4 Card:

Euro Connector

Mobile3 Mobile4 Mobile1 Mobile2

SIM HolderSIM HolderSIM HolderSIM Holder

GSM Module GSM Module

Page 9: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Eternity ME GSM 8 Card

Euro Connector

Mobile7

GSM Module GSM Module

SIM Holder SIM Holder SIM Holder SIM Holder

GSM Module GSM Module

SIM Holder SIM Holder SIM Holder SIM Holder

Mobile8 Mobile5 Mobile6 Mobile3 Mobile4 Mobile2 Mobile1

Refer following steps before installing SIM cards in the Mobile Ports.

Installing SIM in GSM Mobile Port

If you want to use PIN Protection

If it is desired to use the PIN Protection, install the SIM card in

your Mobile handset and enable the PIN Protection.

From the Mobile handset change the PIN to 1234.

Remove the SIM from the Mobile handset and insert in the Mobile

Port of the Eternity.

Installing the SIM with PIN Value 1234, enables you to change

the SIM PIN from the Eternity later on.

If you don't want to use PIN Protection

Insert the SIM in the Mobile handset and make sure that the PIN

Protection is disabled.

Remove the SIM Card from the Mobile handset and install in the

Mobile port of the Eternity.

Installing RUIM CDMA Mobile Port

It is strongly recommended to not to use PIN protection facility for the

Mobile port, used as CDMA.

Page 10: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Using CDMA Mobile Handset, make sure that PIN Protection is

disabled in RUIM.

Do not use PIN Protection enabled RUIM in Eternity, the RUIM might

get blocked.

LED indications for the Mobile Port would be as shown below:

Event ColourCadence in msec (1 cadence is of 3000

msec)

Port Disable - LED Off

Port Idle - LED Off

Port Active (All

states other than

Ring and Speech)

RED Continuous ON

Ring Event GREEN400ms ON-200 ms OFF-400ms ON-200 ms

OFF

Speech GREEN Continuous ON

Module Initialization ORANGE

200ms On-200ms Off-200ms On-200ms Off-

200ms On-200ms Off-200msOn-200ms Off-

200ms On-1200ms Off (5 Blinks)

PUK required ORANGE200ms On-200ms Off-200ms On-200ms Off-

200ms On-200ms Off-200msOn-1600ms Off

SIM PIN faulty ORANGE200ms On-200ms Off-200ms On-200ms Off-

200ms On-2000ms Off (3 Blinks)

SIM Absent ORANGE200ms On-200ms Off-200ms On- 2400ms

Off (2 Blinks)

Network Link Down

(absence of

Network)

ORANGE 200 ms On-2800 ms Off (1 Blink)

If the points related to the PIN protection are not followed, your SIM card

can get blocked and it will require Personal Unblocking Number (PUK) to

reactivate it again.

While Installing VoIP Card

Unpack VoIP Card.

Insert VoIP Card in the universal slot of the system.

Connect one end of the RJ45 cable (provided with the VoIP card) to

Ethernet port of VoIP card and the other end with the LAN switch or broad

band Modem.

Page 11: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

LED indications for the VoIP card would be as shown below:

VoIP Card supports 2 LEDs:

LED 1 Indicates the VoIP Card’s Status.

LED 2 Indicate the status of the SIP Trunk, for which the LED is

assigned.

Indication of LED1 shall be:

Event Colour Cadence

Booting up GREEN Continuous

Stack Construction in

progress

GREEN 200msON-200ms OFF-

200msON-200ms OFF

Stack Construction

Successful

GREEN 1 Sec ON-1 Sec OFF

VoPP Program Down Load

Fail

RED Continuous ON

Stack Construct Failure-

PPPoE Authentication Fail

RED 200ms ON-1sec OFF

Stack Construct Failure-IP

Address Invalid

RED 200ms ON-200ms OFF-

200ms ON-1sec OFF

Indication of LED2 shall be:

Event Colour Cadence

SIP Trunk-Disabled RED Continuous ON

Registration Fail-

Authentication Password

Invalid

RED 200ms ON-1 Sec OFF

(continuous)

Registration Fail-

Configuration Parameters

Invalid

RED 200ms ON-200 ms OFF-

200 ms ON-1 Sec OFF

(continuous)

Registration in Progress GREEN 200 ms ON-1 Sec OFF

(continuous)

Registration successful GREEN Continuous ON

While Installing the T1E1PRI Card

Unpack T1E1PRI Card.

By default, termination resistance of DS1 port set as 120Ω, which is

for E1 connectivity.

To use the DS1 port for T1 connectivity, termination resistance shall be

changed to 100Ω.

Page 12: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

In Eternity ME

DS1 Port -1’s termination resistance can be changed using DIP switch

SW5.

Set Pins of SW5 as shown below to set termination resistance.

Pin-1 Pin-2 Pin-3 Pin-4 Resistance

OFF OFF ON OFF 120 Ohms (for E1)

OFF ON OFF OFF 100 Ohms (for T1)

DS1 Port 2’s termination resistance can be changed using DIP Switch

SW2.

Set Pins of SW2 as shown below to set termination resistance.

Pin-1 Pin-2 Pin-3 Pin-4 Resistance

OFF OFF ON OFF 120 Ohms (for E1)

OFF ON OFF OFF 100 Ohms (for T1)

In Eternity GE

Termination resistance can be changed, using Jumper J5.

In default configuration Jumper J5 is set in AB Position to provide 120Ω

termination resistance, which is for E1 connectivity.

If you want to use the DS1 Port for T1 connectivity set Jumper J5 in BC

position, which shall provide termination resistance of 100Ω.

Connect one end of the RJ45 cable (provided with the T1E1PRI Card) to

the DS1 port and the other end to Modem provided by service provider.

LED indication of T1E1PRI Card of Eternity-ME and Eternity-GE are

shown below:

Eternity-ME

The Eternity ME T1E1PRI Card has four LEDs, viz . L1, L2, L3 and L4.

LED L1 and L2 are assigned to DS1 Port 1, while LED L3 and L4 are

assigned to DS1 Port 2.

LED L1 shows Card Heart Bit as well as status of the PORT1.

Eternity-GE

The Eternity-GE T1E1PRI Card has 2 LEDs, viz. LED1 and LED2.

LED patterns are defined as shown below for different state and signaling

as shown below.

1. Port Active Mode

Page 13: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Signaling Type: E1-PRI

LED1/LED3 Pattern:

PORT Status Colour Cadence

Layer 1 established

successfully

GREEN Continuous ON

CRC4 Alarm GREEN 100ms ON-100 ms OFF

BFA Alarm RED 500ms ON-500 ms OFF

LOS Alarm RED Continuous ON

LED2/LED4 Pattern:

PORT Status Colour Cadence

Layer 1 established

successfully

GREEN Continuous ON

RAI Alarm RED 500ms ON-500 ms OFF

AIS or LOS Alarm RED Continuous ON

Signaling Type: E1-CAS

LED1/LED3 Pattern:

PORT Status Colour Cadence

Layer 1 established

successfully

GREEN Continuous ON

CRC4 Alarm GREEN 100ms ON-100 ms OFF

MFA Alarm RED 100ms ON-100 ms OFF

BFA Alarm RED 500ms ON-500 ms OFF

LOS Alarm RED Continuous ON

LED2/LED4 Pattern:

PORT Status Colour Cadence

Layer 1 established

successfully

GREEN Continuous ON

Y-Bit Alarm GREEN 100ms ON-100 ms OFF

AIS16 Alarm RED 100ms ON-100 ms OFF

RAI Alarm RED 500ms ON-500 ms OFF

AIS or LOS Alarm RED Continuous ON

Page 14: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Signaling Type: T1-RBS or T1-PRI

LED1/LED3 Pattern:

PORT Status Colour Cadence

No Alarm GREEN Continuous ON

TFA Alarm or MFA

Alarm

RED 500ms ON-500 ms OFF

AIS Alarm RED 100ms ON-100 ms OFF

LOS Alarm RED Continuous ON

LED2/LED4 Pattern:

PORT Status Colour Cadence

Layer 1 established

successfully

GREEN Continuous ON

RAI or LOS Alarm RED Continuous ON

2. Port Maintenance Mode

LED1/LED3 Pattern:

PORT Status Colour Cadence

Maintenance Mode RED -

GREEN

500 ms RED-500 ms

GREEN

LED2/LED4 Pattern:

PORT Status Colour Cadence

Near end loop back wait

before activate

RED 100ms ON-100 ms OFF

Near end loop active RED Continuous ON

Near end loop back wait

before deactivate

RED 500ms ON-500 ms OFF

Far end loop back wait

after activate

GREEN 100ms ON-100 ms OFF

Far end loop active GREEN Continuous ON

Far end loop back wait

after deactivate

GREE 500ms ON-500 ms OFF

3. Port Disable Mode

LED1/LED3 Pattern:

PORT Status Colour Cadence

Port Disable RED Continuous ON

Page 15: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

LED2/LED4 Pattern:

PORT Status Colour Cadence

Port Disable Off Off

While Installing VMS Card

Unpack VMS Card.

Insert VMS Card in the universal slot of the system.

LED indication of VMS card In Eternity-ME and Eternity-GE are

shown below:

Condition Colour Cadence

Normal Green 1 sec ON - 1 Sec Off

Disk Error RED 100ms ON - 100ms OFF

File System Error RED Continuous ON

4. Switching ON the system Switch ON the system, it takes 2 to 3 minutes for init.

On completion of the initialisation, LED L1 on master card/CPU card

will blink Green with cadence of 1Sec ON - 1 Sec OFF, continuously.

5. How to reach the Home Page of Web Server?

Connecting the Eternity with the computer

Connect the Ethernet Port of the Eternity to the Ethernet Port of the

Computer using the RJ-45 cable provided with the system.

The default IP Address of the Eternity is 192.168.1.1 and Subnet

Mask is 255.255.255.0.

To access the Eternity using computer, the Eternity and computer

shall be in the same subnet.

Follow below given steps to change the Eternity’s IP Address and

Subnet Mask.

1. Dial 1#91-1234 (1234 is default SE Password) to enter in SE

Mode (from any SLT/DKP).

2. Issue command 2110-<IP Address>, to change IP Address

For example, issue command 2110-192168050010, to change

the IP Address as (192.168.50.10).

3. Issue command 2111-<Subnet Mask>, to change Subnet Mask.

4. Dial 00 to exit from SE Mode.

To change the IP Address and Subnet Mask of the Ethernet port of the

computer go to: My Network Places → Properties → Local Area

Connection → Properties → Internet Protocol (TCP/IP) → Properties.

(For computers with windows 2000 and XP Operating Systems)

Page 16: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

You may also connect the Eternity in the LAN of the organisation. But

make sure that the Eternity and the computer you are using to access the

Eternity are in the same subnet.

Configuring the Eternity using the Web Jeeves

Enter IP address of the Eternity in browser’s address field.

The Eternity will prompt for login as shown below.

Log in as SE

Log in as SA

Log in as Front Desk User

Click on option to 'Log in as SE', if you are a System Engineer.

Feature Menu is displayed on the left side of Welcome page.

Click on Login button after entering valid User Password (default:

1234) for SE:

Page 17: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

On successful log in, you will get 'Home Page'.

Now you can configure the Eternity Using Jeeves.

The left most side of all the Jeeves Page, contains link list.

Click on the link and the respective webpage will get opened.

Make required changes and click on ‘Submit’ given on the bottom of

the webpage to affect the changes.

Page 18: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

6. Select the Country (Region Code)By default, the Country = India. Change the country code from the

webpage, ‘System General Parameters’, Parameter Name - ‘Country’.

Once you have selected the country, give SE command to default the

Eternity from the SLT/DKP as given below:

1. Dial 1#91-SE Password to enter in SE Mode (from any SLT/DKP)

2. Issue command 5302-Reverse SE Password, to load the default

settings for the selected country.

7. Program the Emergency Numbers

Click on the link 'Emergency Numbers'.

First 5 entries of Emergency Number table are non-editable, you can

only assign the OG Trunk Bundle Group to route these numbers. The

default setting of Emergency Number table depends on the Region

you have selected.

In default setting, if you don't find emergency numbers recognised in

your region, program the same at in any index from 6 to 10 and

assign OG Trunk Bundle Group to route this number.

Make sure that trunk lines programmed in OG Trunk Bundle Group

assigned for Emergency Number, are capable of routing the

emergency number, otherwise the emergency services will get

affected.

8. Enterprise Name

Enterprise name of up to 80 characters can be programmed.

Refer, ‘System General Parameters’ - ‘Customer Name’.

9. Time Zone - Automatic (Time Table), Manual Time Zone

By default, all the stations and trunks are assigned Time Table -1.

The default settings of the Time Table-1 is given below:

Working Hours 09:00 to 18:00

Break Hours 13:00 to 14:00

Non working hours: 18:00 to 09:00

Refer, ‘Time Tables’ to make changes in this time table.

Refer ‘Station Basic Feature Template’ to assign time table to station.

Refer ‘Trunk Feature Template’ to assign time table to trunk.

It is also possible to set the time zone for the stations and trunks

manually, refer System Manual for more details.

Page 19: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

10. Program flexible numbers

By default, stations are assigned flexible numbers as given below:

SLT : 2001 to 2512

DKP : 3001 to 3128

ISDN Terminal : 3201 to 3264

Refer ‘SLT Parameters’ to change the flexible numbers of SLTs.

Refer ‘DKP Parameters’ to change the flexible numbers of DKPs.

Refer ‘ISDN Terminal Parameters’ to change the flexible numbers of

ISDN terminals.

11. DSS Console Each Digital Key Phone can be assigned maximum 2 DSS Consoles

Refer, "DKP Parameters", to assign DSS console to DKP.

Hardware Slot - Port, to which DSS is connected, shall be assigned to

the desired DKP port as "DSS 1 H/w Slot - Port".

To attach second DSS console to same DKP Port, assign hardware

slot - port of other DSS console to the DKP port as "DSS 1 H/w Slot -

Port" parameters.

Example:

DKP Card is installed in slot 05.

Digital Key Phones are connected on 1st and 2nd port of the DKP Card.

One DSS is connected to 3rd port of DKP Card.

Second DSS is connected on 4th port of the DKP Card.

To assign one DSS to each DKP port following programming shall be

done in "DKP Parameters".

To assign both DSS to DKP -001 following programming shall be

done in "DKP Parameters".

Page 20: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

12. CLIP

CLI detection on TRK

By default for region code India, all TRK ports are configured to

etect the DTMF CLI, refer TWT Hardware Template-Rx CLI Type.

Know the CLI type supported by exchange and configure this

parameter accordingly.

CLI presentation on SLT

In default settings for India and other regions except United

States, Mexico, Namibia and Canada, all SLT ports are assigned

SLT Hardware Template -01.

By default, CLIP Type is set as DTMF, in SLT Hardware

Template - 01.

Refer, ‘SLT Hardware Template (01)’ - CLIP Type, to change

it if required.

In default settings for regions United States, Canada, Mexico and

Namibia all SLT ports are assigned SLT Hardware Template-06.

By default, CLIP Type is set as FSK Bellcore, in SLT

Hardware Template - 06.

Refer, ‘SLT Hardware Template (06) - CLIP Type, to change it

as required.

Know the CLIP protocol supported by the telephone instrument to

be connected on SLT Port and configure this parameter

accordingly.

You may assign different SLT Hardware Template to different SLT

Ports if required. Refer, ‘SLT Parameters’ to assign SLT

Hardware Template to SLT.

No configuration is required for CLI detection on Mobile, DS1, BRI and

SIP Trunks.

No configuration is required for presenting the CLI on DKP and ISDN

Terminals.

Page 21: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

13. Class of Service

Class of Service is part of Station Basic Feature Template, by default

all the stations are assigned Station Basic Feature Template-01, in

which COS group 03 is assigned for working hour, break hours and

non-working hours.

Refer ‘Class of Service’ to check the default settings of the CoS

group 03 and customise CoS group as required.

Refer Station Basic Feature Template to change the default CoS

group assigned to the station

Station can be assigned different COS group by assigning different

Station Basic Feature Templates.

Refer SLT Parameters to change Station Basic Feature Template

assigned to SLT Ports. Refer, ‘DKP Parameters’ to change Station

Basic Feature Template assigned to DKP Ports. Refer ‘ISDN

Terminal Parameters’ to change Station Basic Feature Templates

assigned to ISDN Terminals.

14. Toll Control

Toll control is part of Station Basic Feature Template, by default all the

stations are assigned Station Basic Feature Template - 01.

By default, all the stations are assigned Allowed List - 03 and Denied

List - 03 for working hour, break hours and non-working hours.

By default, all the stations are allowed to make Local, STD and ISD

calls.

Refer ‘External Number List’ to customise allowed and denied number

Lists as required.

Refer Station Basic Feature Template assigned to the station to

change number list assigned in default settings.

15. Trunk Access

Trunk Access is part of Station Basic Feature Template, by default all

the stations are assigned Station Basic Feature Template - 01.

By default all stations are assigned OG Trunk Bundle Group = 01.

By default members of the OG Trunk Bundle Group-01 are none,

means in default configuration the stations are not given access to

any trunks.

Refer OG Trunk Bundle to form the OG Trunk Bundles as desired.

Refer OG Trunk Bundle Group, program the OG Trunk Bundles as

members of the OG Trunk Bundle Group.

Refer Station Basic Feature Template assigned to the station, to

assign different OG Trunk Bundle Group for different Trunk Access

Codes.

Page 22: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

16. LCR

By default, LCR is disabled on all the OG Trunk Bundle Groups.

Refer ‘OG Trunk Bundle Group’ - LCR Type, to enable the required

LCR type.

Refer links of Least Cost Routing to program attributes of the LCR.

17. Trunk Landing

Routing the incoming call to Trunk Landing Group

By default all the trunks are assigned trunk landing group (routing

group) 01.

By default members of the routing group 01, are DKP 001 to 008

and SLT 001 to 008.

Refer ‘Routing Groups’ to program the routing groups with

desired members.

Refer Trunk Feature Template to assign the routing group to trunk

for working hours, break hours and non working hours.

DID

By default DID is disabled on all the trunks for working hours,

break hours and non working hours.

Refer Trunk Feature Template to enable DID for the working

hours, break hours and non working hours as desired.

Refer Voice Message Applications to assign voice modules for

the different messages of the DID.

CLI Based Routing

By default all the entries of the CLI Based Routing Table are

blank.

Refer ‘CLI Based Routing’ to program the desired destination for

particular calling number.

DDI (Direct Dialing In)

Refer DS1 Port Parameter, to assign IC Reference ID and OG

Reference ID to DS1 Port for working hours, break hours and non

working hours.

Refer links of the DDI Routing, viz. IC Reference Table, DDI

Routing Table and Outgoing Reference Table to program DDI

Routing.

For more details refer System Manual.

Trunk Auto Answer

By default Trunk Auto Answer is disabled on all the trunks for

working hours, break hours and non-working hours.

Refer Trunk Feature Template to enable Trunk Auto Answer for

Page 23: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

the working hours, break hours and non-working hours as

desired.

Refer Voice Message Applications to assign voice modules for

the Auto Answer Greeting message, Auto Answer RBT message

and Auto Answer Bye message.

DISA

By default DISA is disabled on all the trunks for working hours,

break hours and non-working hours.

Refer Trunk Feature Template to enable DISA for the working

hours, break hours and non-working hours as desired.

Refer system manual chapter “Incoming Call Management” for more

details and interactions of DID, DISA, Trunk Auto Answer, DDI and CLI

Based Routing.

18. Program the Operator Group

By default, all the stations and trunks are assigned operator-1.

By default routing group number 32 is programmed as operator-1 for

working hours, break hours and non-working hours.

By default, members of the Routing Group 32 are DKP001 to 008 and

SLT 001 to 008.

Made list of operator station for working hours, break hours and non

working hours.

Refer Routing Group to form routing groups with members which are

to be used as operator for working hours, break hours and non

working hours.

Refer Operators to assign the routing group as operators.

Refer Station Basic Feature Template to assign operator to the

station.

Refer Trunk Feature Template to assign operator for the trunk.

19. DS1 Port

By default, the orientation type of the DS1 port is Terminal.

To connect the DS1 port with the Public network, orientation type of

the DS1 port shall be Terminal (TE).

To connect the DS1 port for private networking, the orientation type

shall be set to Terminal/Network depending on the network scenario.

Refer DS1 Port Parameters to configure the basic attributes of the

DS1 port.

By default, the DS1 port is set to support “E1 PRI” signaling. Refer

‘DS1 Port Parameters’ - ‘Signal Type’ to change the signaling as T1

PRI/E1 CAS/T1 RBS as supported by the exchange (Network).

Page 24: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

E1 PRI Signaling

Know the PRI switch variant supported by exchange.

In case of private networking set the ISDN switch variant

supported by both the PBXs.

By default, the PRI Switch variant is ‘ETSI NET5’.

Refer ‘PRI Parameters’, to change the attributes of the PRI

signaling.

E1 CAS Signaling

To set E1 CAS signaling on DS1 port, go to ‘DS1 Port Parameter’

- ‘Signal Type’, configure it as ‘E1 CAS’.

By default the E1 Line Signaling Variant is ‘ITU T Q.400 – Q.490’

and E1 Registered Signaling variant is ‘MFC R2’.

Know the Line Signaling and Registered Signaling variant

supported by the exchange, while in case of private networking

use the signaling variant supported by both the PBXs.

Refer ‘E1 CAS Parameters’, to change the attributes of the E1

CAS signaling.

T1 RBS Signaling

To set T1 RBS signaling on DS1 port, go to ‘DS1 Port Parameter’

- ‘Signal Type’, configure it as ‘T1 RBS’.

By default the T1 Line Signaling Variant is ‘E&M Wink Start FGD’

and Registered Signaling variant is ‘DTMF’.

Know the T1 Line Signaling and Registered Signaling variant

supported by the exchange, while in case of private networking

set the signaling variant supported by both the PBXs.

Refer ‘T1 RBS Parameters’, to change the attributes of the T1

RBS signaling.

Each DS1 Port is assigned following templates in default

configuration:

Trunk Feature Template Number 01

Station Basic Feature Template Number 01

Station Advance Feature Template Number 01

The assigned templates can be changed or customised as required.

When DS1 port orientation type is Terminal, the Trunk Feature Template

assigned to it is of relevance.

When DS1 port orientation type is Network, the Station Basic Feature

Template and Station Advance Feature Template assigned to it are of

relevance.

Page 25: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

20. Mobile Port

SIM Card subscribed from the GSM Service Provider can be installed

in the GSM Mobile Port.

RUIM subscribed from the CDMA service provider can be installed in

the CDMA Mobile port.

Make sure that you are installing the Eternity where sufficient network

coverage is available.

Band Selection:

Select the Frequency Band which is used by your Service

Provider. In default configuration Mobile Port is set to operate at

900+1800 MHz. Refer parameter ‘Band Selection’ in “Mobile Port

Parameters” to change the Band for the Mobile Port.

Network Selection:

Important Points:

In GSM you can select and use network selection as 'Automatic'/

'Manual' as desired.

In CDMA, manual network selection is not supported; hence in

CDMA it is must to use Automatic network selection.

Refer ‘Mobile Network Selection’ for configuring the Network

related attributes.

By default, all Mobile ports are configured to select the

network automatically. The Network Selection Mode is

Automatic.

If the network is to be selected manually, set the ‘Network

Selection Mode’ as Manual. Program the Network Operator

code (MCC-MNC) in priorities for the Mobile Port.

Refer ‘Mobile Port Parameters’ and ‘Mobile Network Selection’ for

configuring the Mobile Port’s attributes.

By default Mobile ports are assigned Trunk Feature Template number

01.

21. BRI Port

By default, the orientation type of the BRI port is Terminal.

To connect the BRI port with public network, orientation type of the

BRI port shall be Terminal.

By default, the BRI Switch variant for the BRI port is ‘ETSI NET 3’.

Know the BRI switch variant supported by public network. Refer ‘BRI

Parameters’, to change the attributes of the BRI Port.

To connect the BRI port for private networking, orientation type can

be set as Network/Terminal depending on the private network

Page 26: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

scenario. Select the BRI Switch Variant which is supported by both

the PBXs.

To connect the ISDN Terminals with the BRI Port, orientation type of

BRI port shall be set as Network. Check the BRI Switch Variant

supported by the BRI port and the ISDN terminals; choose the

common switch variants supported by them.

Each BRI Port is assigned following templates in default

configuration:

Trunk Feature Template-01

Station Basic Feature Template -01

Station Advance Feature Template -01

The assigned templates can be changed or customised as required.

When BRI port is configured as Terminal, the Trunk Feature Template

assigned to it is of relevance.

When BRI port is configured as Network, the Station Basic Feature

Template and Station Advance Feature Template assigned to it is of

relevance.

Refer ‘ISDN Terminal Parameters’ for configuration of ISDN Terminal

interfaced with the BRI Port.

22. E&M Trunk

By default, E&M Port is assigned following templates in default

configuration.

E&M Feature Template - 01

Trunk Feature Template - 01

Station Basic Feature Template - 01

Station Advance Feature Template - 01

Refer, “E&M Parameters”, to assign different template to the E&M

Port.

By default Seizure Type for the E&M port is Immediate, refer E&M

Feature Template to change the Seizure Type as required.

By default Release Type for the E&M port is Status Change, refer

E&M Feature Template to change the Release Type as required.

By default Orientation Type for the E&M port is Station, refer E&M

Feature Template to change the Orientation Type as required.

By default the Dial Type for the E&M port is Pulse, with Pulse Dial

Ratio 10PPS 1:2, refer E&M Feature Template to change the Dial

Type to Tone if required.

Station Advance Feature Template and Station Basic Feature Template is

of significance when E&M Port orientation type is Station.

Page 27: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Trunk Feature Template is of significance when E&M Port orientation type

is Trunk.

23. VoIP Ethernet Port

To make VoIP calls you must have,

Broadband Internet Connection to make/receive calls through Public

Internet. If you wish to make calls within your network, you do not

need an Internet connection.

A SIP Account with an Internet Telephony Service Provider (ITSP). If

you want to make peer-to-peer calls (i.e. calls made without

intervention of SIP Server or Proxy Server) you do not need the

service of ITSP.

Configuring the VoIP Ethernet Port

To configure VoIP Ethernet Port, refer “VoIP Ethernet Port

Parameters”.

Know the Connection Type of the LAN from Administrator and

configure the ‘Connection Type’ for the VoIP Ethernet Port

accordingly.

If Connection Type = Static

The default connection type is set as Static for all the VoIP

Ethernet Ports.

Default IP Address of the VoIP Ethernet Port is

192.168.1.116, and Network Mask is 255.255.255.0, change

the IP address and Network Mask as per your LAN

Addressing scheme.

Program the Router’s LAN interface IP Address as a

‘Gateway IP Address’ for the VoIP Ethernet Port.

Program the DNS Address/Domain Name as provided by

your Internet Service Provider.

If Connection Type = DHCP

Change the Connection Type to DHCP.

The VoIP Ethernet Port IP Address, Network Mask and

Gateway Address will be provided by dynamically by the

DHCP server on LAN. You have to set the DNS address only.

If DHCP server provides DNS address, set the ‘DNS

Connection Type’ to Auto

If DHCP server does not provide DNS address, program the

DNS server address/DNS Name as provided by your Internet

Service Provider.

Page 28: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

If Connection Type = PPPoE

Change the Connection Type to PPPoE.

The PPPoE server will automatically assign the VoIP

Ethernet Port IP Address, Network Mask and Gateway

Address.

Program the PPPoE User name and Password as provided

by the Internet Service Provider.

If PPPoE server doesn’t provide the DNS address, program

the DNS Address/DNS Name as provided by your Internet

Service Provider.

If DNS address is provided by the PPPoE server, set the

‘DNS Connection Type’ to Auto.

24. SIP Trunk

To configure SIP Trunk refer, ‘SIP Trunk Parameters’

Configure Proxy SIP Trunk as shown below:

Assign the VoIP Port to be used for the SIP Trunk.

Enable the SIP Trunk.

Program the SIP ID, Registrar Server Address, Registrar

Server Port, Authentication ID, Authentication Password as

provided by your ITSP.

If your ITSP uses Outbound Proxy, Enable the Outbound

Proxy for the SIP Trunk and also program the Outbound

Proxy Server Address and Port as provided by your ITSP.

25. VMS Card

The Eternity automatically assigns un-used SLT software ports (i.e.

SLT ports which are not assigned any hardware slot-port) as VMS

port.

The SLT software ports used by VMS card are automatically gets

configured in Routing Group number 33.

The Eternity automatically assigns Routing Group number 33 as VMS

Group.

Default access code of VMS group is 3931, refer ‘Access Codes’ -

VMS Group, to change default access code.

To land incoming calls at VMS, program Routing Group 33 as TLG in

the trunk feature template assigned to the respective trunk.

By default there is no Message Wait Notification for all stations.

Message wait notification is part of Station Advance Feature template,

hence refer Station Advance Feature Template assigned to the station

to set Message Wait Notification Type as required.

VMS is also referred as ‘CadencePro’ in Eternity.

Page 29: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Configuring the VMS Card

Collect following information:

Decide to which extension numbers, mailbox has to be assigned.

If Ethernet port of CadencePro is going to be connected in the

network, consult LAN administrator and get the IP Address and

Subnet mask to be assigned to the Candencepro.

How to reach the Home Page of Web Server of VMS?

Connecting the VMS card with the computer

Connect the Ethernet Port of the VMS Card to the Ethernet Port of

the Computer using the RJ-45 cable provided with the card.

The default IP Address of the VMS card is 192.168.1.131 and Subnet

Mask is 255.255.255.0.

To access the web server of VMS card using computer, the VMS

Ethernet port and computer shall be in the same subnet.

Follow below given steps to change the VMS Ethernet port IP

Address and Subnet Mask:

Step 1: Entering into the Programming mode

Dial VMS Group access code (Default 3931) from any station

VMS will answer the call and greet with Welcome Message.

Dial *19-1234 (1234 is the default SE Password of VMS) during

the Welcome message.

VMS will greet with “Enter the Programming Command”.

Step 2: Assigning an IP Address

Enter into the programming mode by following the step 1 i.e.

“Entering into the Programming mode”.

Dial the SE command 1501-IP Address-#*.

For example, if the IP address 192.168.1.182 is to be

programmed, the SE command shall be given as,

1501-192168001182-#*.

VMS card will restart once you enter this command.

Step 3: Assigning an Subnet Mask

Enter into the programming mode by following the step 1. i.e

“Entering into the Programming mode”.

Dial the SE command 1502-Subnet Mask-#*.

For example, if the subnet mask 255.255.255.0 is to be

programmed, the SE command shall be given as, 1502-

Page 30: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

255255255000-#*.

VMS will restart once you enter this command.

You may also connect the VMS card port in LAN of the organization. But

make sure that the VMS card and the computer you are using to access it

are in the same subnet.

Configuring the VMS using the Web Interface

Access the Webjeeves of the CadencePro

Open the Web browser/Internet Explorer.

Enter the IP address of the CadencePro Network Port in the URL field of

the Web browser/Internet Explorer and press Enter key.

The CadencePro will prompt for login as shown below:

You can enter the User name of your choice. (Entering the user name is

not mandatory for login.)

Enter the SE Password (default: 1234) in the ‘Password’ field.

Click on the ‘Login’ button.

On successful login, you will be taken to the Home Page.

Page 31: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Now, you can configure the CadencePro using Web Jeeves.

The left most side displays the link for different web pages for configuring.

Click on the link and the respective webpage will get opened.

Make required changes and click on ‘Submit’ button given on the bottom

of the webpage to affect the changes.

Configuring the Region Code:

By default, Region Code = ‘India’.

To change the Region code, click on the link “System Parameters” and

refer Region Code options.

Select the Region code from the list and Submit the page.

Following parameters would be changed as per the Region code

programmed:

Operator code for Home Node

DST type

Welcome Messages for Port

Configuring the Date & Time Settings:

Click on the link “Date & Time Settings” and Date & Time Settings

webpage will open as given below:

Page 32: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Current Date & Time:

Program the Current Date and Current Time.

Current date & time is required in the system because certain

features like Time table, holidays, Greetings, etc. relates to date & time.

Time Table:

Program the start time and end time of working hours for weekdays in the

Time Table. Remaining time would be considered as Non-working hours.

Welcome messages are played according to the time table programmed.

For example:

For Monday, Start time is programmed as 09:00 and End time is

programmed as 18:00 for working hours.

Thus, 00:00 to 08:59 and 18:00 to 23:59 would be considered as Non-

working hours.

Holidays:

Program the date and month of holidays.

On holidays, time table would not be applicable and Welcome message is

played according to the holidays.

Configuring the Station Parameters:

Click on the link “Station Parameters” and Station Parameters webpage

will open as given below:

Page 33: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Extension Number:

Program the Extension numbers of the PBX which are to be

allowed.

Mailbox Number:

By default, no Mailbox is assigned to any Station number.

Assign the Mailbox number (001-512) to the Station Number if

mailbox facility is to be given. Use 000 for not assigning a

mailbox number.

Same mailbox number should not be assigned to two different

station numbers.

For changing the Mailbox related parameters, refer topic

“Configuring the Mailbox Parameters”.

Abbreviated Name:

By default, blank for all station number.

Assign abbreviated name if dial by name feature is to be used

Only 3 alphabets of the station user name can be programmed in

Abbreviated name and it should be enter in capital letters i.e for

example: program ‘RAK’ for Rakesh.

Mode:

Mode for each station is used for transfer type.

Different Modes supported are Manual and Scheduled.

Program Manual mode for Station if Transfer type is to be kept

fixed through out the day.

Program Scheduled mode for Station if Transfer type is to be kept

different at different time of the day.

By default, Mode = Manual.

Page 34: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

If Manual Mode is programmed:

Program the Transfer type in the field “Manual Mode Transfer

Type” for the station.

By default, Manual Mode Transfer Type = Wait for Answer.

For different transfer types refer “Transfer Types”.

If Scheduled Mode is programmed:

Program Start Time and Transfer Type for Time Zone 1 - Time

Zone 4 in Scheduled Mode.

Start Time for Time Zone 1-Time Zone 4:

By default, Start Time = 00.00.

Start time of Time Zone 2 is the End time of Time Zone 1 and

so on. Thus, program the Start time accordingly.

Transfer Type for Time Zone 1-Time Zone 4:

By default, Transfer Type = Wait for Answer

For different transfer types refer “Transfer Types”.

Transfer Types:

Different transfer type which can be set is as given below:

None - Directly transfers the caller to the mailbox if assigned.

Blind - Directly transfers the caller to the extension number

dialed by the caller without knowing the status of the extension i.e

whether it is busy or not.

Wait for Ring - Transfers the caller to the extension number

dialed by the caller if the extension is ringing i.e ring is detected

by the CadencePro.

Wait for Answer - Transfers the caller to the extension number

dialed by the caller only if it is answered.

Screen - CadencePro asks the caller to record its name and the

recorded name is played to the extension number dialed by the

caller if it answers. If extension user accepts the call it is

transferred otherwise takes the caller to the home node.

Configuring the Mailbox Parameters:

Click on the link “Mailbox Parameters” and Mailbox Parameters webpage

will open as given below:

Page 35: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Mailbox Size:

Default Mailbox size = 5 minutes for each mailbox. Maximum size

of mailbox can be of 999 minutes for each mailbox.

Change the Mailbox size for mailbox depending upon who is the

Station user.

Maximum Message Length:

Default Maximum Message Length = 15 seconds for each

mailbox. Maximum message length can be of 999 seconds.

Change the Message length of the mailbox depending upon who

is the Station user.

Ask Mailbox Password at Login:

Default = Yes.

You can also programmed it as ‘No’ i.e password will not be

asked from the station user while accessing the mailbox.

Message Notification:

Default = No.

Program it as ‘Yes’ for the mailbox depending upon the station

user.

Checking the VMS installation

Dial the VMS group number (default 3931) form station. The call shall be

automatically answered by the VMS and you shall hear the voice

message programmed in the VMS.

Page 36: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

26. Disconnect tone Detection

If you are using TRK and using DID (Auto Attendant) on the same,

enable Disconnect Tone Detection and program Disconnect Tone

Cadence in TWT hardware Template assigned to TRK.

For more detail refer, Eternity System manual - Disconnect Tone

Detection.

27. Change the SE password

Once you finish installation, you are advised to change the SE

password to prevent unauthorised access.

Refer “Change Password” to change the SE password.

Appendix

Cable Diagram for cards of Eternity-ME

Port Color Port Color Port Color PORT COLOR

SLT01 Blue-White SLT01 Blue-White SLT01 Blue-White SLT17 Blue-White

SLT02 Orange-White SLT02 Orange-White SLT02 Orange-White SLT18 Orange-White

SLT03 Green-White SLT03 Green-White SLT03 Green-White SLT19 Green-White

SLT04 Brown-White SLT04 Brown-White SLT04 Brown-White SLT20 Brown-White

SLT05 Grey-White SLT05 Grey-White SLT05 Grey-White SLT21 Grey-White

SLT06 Blue-Red SLT06 Blue-Red SLT06 Blue-Red SLT22 Blue-Red

SLT07 Orange-Red SLT07 Orange-Red SLT07 Orange-Red SLT23 Orange-Red

SLT08 Green-Red SLT08 Green-Red SLT08 Green-Red SLT24 Green-Red

SLT09 Brown-Red SLT09 Brown-Red SLT25 Brown-Red

SLT10 Grey-Red SLT10 Grey-Red SLT26 Grey-Red

SLT11 Blue-Black SLT11 Blue-Black SLT27 Blue-Black

SLT12 Orange-Black SLT12 Orange-Black SLT28 Orange-Black

SLT13 Green-Black SLT13 Green-Black SLT29 Green-Black

SLT14 Brown-Black SLT14 Brown-Black SLT30 Brown-Black

SLT15 Grey-Black SLT15 Grey-Black SLT31 Grey-Black

SLT16 Blue-Yellow SLT16 Blue-Yellow SLT32 Blue-Yellow

SLT32

(Upper MDF Connector)SLT08 SLT16

SLT32

(Lower MDF Connector)

Port Color Port Color

TWT01 Grey-Black TWT05 Grey-Black

TWT02 Blue-Yellow TWT06 Blue-Yellow

TWT03 Orange-Yellow TWT07 Orange-Yellow

TWT04 Green-Yellow TWT08 Green-Yellow

TWT08

(Lower MDF Connector)

TWT08

(Upper MDF Connector)

Page 37: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Port Color

SLT01 Blue-White

SLT02 Orange-White

SLT03 Green-White

SLT04 Brow n-White

SLT05 Grey-White

SLT06 Blue-Red

SLT07 Orange-Red

SLT08 Green-Red

SLT09 Brow n-Red

SLT10 Grey-Red

SLT11 Blue-Black

SLT12 Orange-Black

TWT01 Green-Black

TWT02 Brow n-Black

TWT03 Grey-Black

TWT04 Blue-Yellow

TWT04+SLT12

Port Color PORT COLOR

SLT01 Blue-White SLT13 Blue-White

SLT02 Orange-White SLT14 Orange-White

SLT03 Green-White SLT15 Green-White

SLT04 Brown-White SLT16 Brown-White

SLT05 Grey-White SLT17 Grey-White

SLT06 Blue-Red SLT18 Blue-Red

SLT07 Orange-Red SLT19 Orange-Red

SLT08 Green-Red SLT20 Green-Red

SLT09 Brown-Red SLT21 Brown-Red

SLT10 Grey-Red SLT22 Grey-Red

SLT11 Blue-Black SLT23 Blue-Black

SLT12 Orange-Black SLT24 Orange-Black

TWT01 Green-Black TWT05 Green-Black

TWT02 Brown-Black TWT06 Brown-Black

TWT03 Grey-Black TWT07 Grey-Black

TWT04 Blue-Yellow TWT08 Blue-Yellow

TWT08+SLT24

(Lower MDF Connector)

TWT08+SLT24

(Upper MDF Connector)

Page 38: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Port Color

DKP01 Blue-White

DKP02 Orange-White

DKP03 Green-White

DKP04 Brown-White

DKP05 Grey-White

DKP06 Blue-Red

DKP07 Orange-Red

DKP08 Green-Red

DKP09 Brown-Red

DKP10 Grey-Red

DKP11 Blue-Black

DKP12 Orange-Black

DKP13 Green-Black

DKP14 Brown-Black

DKP15 Grey-Black

DKP16 Blue-Yellow

DLC08/DLC16 CARD

Port Color

E&M01-M, SB Blue-White

E&M01-E, SG Orange-White

E&M01-SP(RxA), SP(RxB) Green-White

E&M01-SP(A), SP(B) Brown-White

E&M01-02 CCS Grey-White

E&M02-M, SB Blue-Red

E&M02-E, SG Orange-Red

E&M02-SP(RxA), SP(RxB) Green-Red

E&M02-SP(A), SP(B) Brown-Red

E&M03-M, SB Grey-Red

E&M03-E, SG Blue-Black

E&M03-SP(RxA), SP(RxB) Orange-Black

E&M03-04 CCS Green-Black

E&M04-M, SB Brown-Black

E&M04-E, SG Grey-Black

E&M04-SP(RxA), SP(RxB) Blue-Yellow

E&M04-SP(A), SP(B) Orange-Yellow

E&M04 CARD

Page 39: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Port Color Port Color

E&M01-M, SB Blue-White E&M05-M, SB Blue-White

E&M01-E, SG Orange-White E&M05-E, SG Orange-White

E&M01-SP(RxA), SP(RxB) Green-White E&M05-SP(RxA), SP(RxB) Green-White

E&M01-SP(A), SP(B) Brown-White E&M05-SP(A), SP(B) Brown-White

E&M01-02 CCS Grey-White E&M05-06 CCS Grey-White

E&M02-M, SB Blue-Red E&M06-M, SB Blue-Red

E&M02-E, SG Orange-Red E&M06-E, SG Orange-Red

E&M02-SP(RxA), SP(RxB) Green-Red E&M06-SP(RxA), SP(RxB) Green-Red

E&M02-SP(A), SP(B) Brown-Red E&M06-SP(A), SP(B) Brown-Red

E&M03-M, SB Grey-Red E&M07-M, SB Grey-Red

E&M03-E, SG Blue-Black E&M07-E, SG Blue-Black

E&M03-SP(RxA), SP(RxB) Orange-Black E&M07-SP(RxA), SP(RxB) Orange-Black

E&M03-04 CCS Green-Black E&M07-08 CCS Green-Black

E&M04-M, SB Brown-Black E&M08-M, SB Brown-Black

E&M04-E, SG Grey-Black E&M08-E, SG Grey-Black

E&M04-SP(RxA), SP(RxB) Blue-Yellow E&M08-SP(RxA), SP(RxB) Blue-Yellow

E&M04-SP(A), SP(B) Orange-Yellow E&M08-SP(A), SP(B) Orange-Yellow

E&M08 CARD

(Lower MDF Connector)

E&M08 CARD

(Upper MDF Connector)

Port Port Port Color

BRI01 TxA, TxB Blue-White BRI05 TxA, TxB Blue-White

BRI01 RxA, RxB Orange-White BRI05 RxA, RxB Orange-White

BRI01 V-, V+ Green-White BRI05 V-, V+ Green-White

BRI02 TxA, TxB Brown-White BRI06 TxA, TxB Brown-White

BRI02 RxA, RxB Grey-White BRI06 RxA, RxB Grey-White

BRI02 V-, V+ Blue-Red BRI06 V-, V+ Blue-Red

BRI03 TxA, TxB Orange-Red BRI07 TxA, TxB Orange-Red

BRI03 RxA, RxB Green-Red BRI07 RxA, RxB Green-Red

BRI03 V-, V+ Brown-Red BRI07 V-, V+ Brown-Red

BRI04 TxA, TxB Grey-Red BRI08 TxA, TxB Grey-Red

BRI04 RxA, RxB Blue-Black BRI08 RxA, RxB Blue-Black

BRI04 V-, V+ Orange-Black BRI08 V-, V+ Orange-Black

BRI04/BRI08 CARD

(Lower MDF Connector)

BRI04/BRI08 CARD

(Lower MDF Connector)

Page 40: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Cable Diagram for cards of Eternity-GE

Port Color Port Color

SLT01 Blue-White SLT01 Blue-White

SLT02 Orange-White SLT02 Orange-White

SLT03 Green-White SLT03 Green-White

SLT04 Brown-White SLT04 Brown-White

SLT05 Grey-White SLT05 Grey-White

SLT06 Blue-Red SLT06 Blue-Red

SLT07 Orange-Red SLT07 Orange-Red

SLT08 Green-Red SLT08 Green-Red

SLT09 Brown-Red

SLT10 Grey-Red

SLT11 Blue-Black

SLT12 Orange-Black

SLT13 Green-Black

SLT14 Brown-Black

SLT15 Grey-Black

SLT16 Blue-Yellow

SLT08 SLT16

Port Color Port Color

TWT01 Blue-White SLT01 Blue-White

TWT02 Orange-White SLT02 Orange-White

NC Green-White SLT03 Green-White

NC Brown-White SLT04 Brown-White

SLT01 Grey-White NC Grey-White

SLT02 Blue-Red NC Blue-Red

SLT03 Orange-Red TWT01 Orange-Red

SLT04 Green-Red TWT02 Green-Red

SLT05 Brown-Red TWT03 Brown-Red

SLT06 Grey-Red TWT04 Grey-Red

SLT07 Blue-Black NC Blue-Black

SLT08 Orange-Black NC Orange-Black

SLT09 Green-Black

SLT10 Brown-Black

SLT11 Grey-Black

SLT12 Blue-Yellow

SLT13 Orange-Yellow

SLT14 Green-Yellow

TWT02 + SLT14 TWT04+SLT04

Page 41: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Port Color

DKP01 Blue-White

DKP02 Orange-White

DKP03 Green-White

DKP04 Brown-White

DKP05 Grey-White

DKP06 Blue-Red

DKP07 Orange-Red

DKP08 Green-Red

DLC04 / DLC08 CARD

Port Color

SLT01 Blue-White

SLT02 Orange-White

SLT03 Green-White

SLT04 Brown-White

SLT05 Grey-White

SLT06 Blue-Red

SLT07 Orange-Red

SLT08 Green-Red

SLT09 Brown-Red

SLT10 Grey-Red

SLT11 Blue-Black

SLT12 Orange-Black

DKP01 Green-Black

DKP02 Brown-Black

DKP03 Grey-Black

DKP04 Blue-Yellow

DLC04+SLT12

DLC02+SLT06

Page 42: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Port Color

E&M01-M, SB Blue-White

E&M01-E, SG Orange-White

E&M01-SP(RxA), SP(RxB) Green-White

E&M01-SP(A), SP(B) Brown-White

E&M01-02 CCS Grey-White

E&M02-M, SB Blue-Red

E&M02-E, SG Orange-Red

E&M02-SP(RxA), SP(RxB) Green-Red

E&M02-SP(A), SP(B) Brown-Red

E&M03-M, SB Grey-Red

E&M03-E, SG Blue-Black

E&M03-SP(RxA), SP(RxB) Orange-Black

E&M03-04 CCS Green-Black

E&M04-M, SB Brown-Black

E&M04-E, SG Grey-Black

E&M04-SP(RxA), SP(RxB) Blue-Yellow

E&M04-SP(A), SP(B) Orange-Yellow

E&M02/E&M04 CARD

Connector Port Colour

RJ45-1 SLT 01 Blue - (Blue & White)(Blue) SLT 02 Orange - (Orange & White)

SLT 03 Green - (Green & White)SLT 04 Brown - (Brown & White)

RJ45-2 SLT 05 (Orange) SLT 06

SLT 07SLT 08

RJ45-3 SLT 09 (Green) SLT 10

SLT 11SLT 12

RJ45-4 SLT 13 (Brown) SLT 14

SLT 15SLT 16

Blue - (Blue & White)Orange - (Orange & White)Green - (Green & White)Brown - (Brown & White)

Blue - (Blue & White)Orange - (Orange & White)Green - (Green & White)Brown - (Brown & White)

Blue - (Blue & White)Orange - (Orange & White)Green - (Green & White)Brown - (Brown & White)

SLT16 Card

L1 L2

1

2

3

4

Page 43: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

L1 L2

1

2

3

4

TRK16 Card

Connector Port Colour

RJ45-1 TRK 01 Blue - (Blue & White)(Blue) 02 Orange - (Orange & White)

03 Green - (Green & White) 04 Brown - (Brown & White)

RJ45-2 05 (Orange) 06

07 08

RJ45-3 09 (Green) 10

11 12

RJ45-4 13 (Brown) 14

15 16

TRKTRKTRK

TRK Blue - (Blue & White)TRK Orange - (Orange & White)TRK Green - (Green & White)TRK Brown - (Brown & White)

TRK Blue - (Blue & White)TRK Orange - (Orange & White)TRK Green - (Green & White)TRK Brown - (Brown & White)

TRK Blue - (Blue & White)TRK Orange - (Orange & White)TRK Green - (Green & White)TRK Brown - (Brown & White)

L1 L2

1

2

3

4

TWT8 Card

Connector Port Colour

RJ45-1 TWT 01 Blue - (Blue & White) 02 Orange - (Orange & White) 03 Green - (Green & White) 04 Brown - (Brown & White)

RJ45-2 05 06 07 08

RJ45-3

RJ45-4

TWTTWTTWT

TWT Blue - (Blue & White)TWT Orange - (Orange & White)TWT Green - (Green & White)TWT Brown - (Brown & White)

Blue - (Blue & White)Orange - (Orange & White)Green - (Green & White)Brown - (Brown & White)

Blue - (Blue & White)Orange - (Orange & White)Green - (Green & White)Brown - (Brown & White)

Page 44: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

L1 L2

1

2

3

4

DKP16 Card

Connector Port Colour

RJ45-1 DKP 01 Blue - (Blue & White)(Blue) 02 Orange - (Orange & White)

03 Green - (Green & White) 04 Brown - (Brown & White)

RJ45-2 05 (Orange) 06

07 08

RJ45-3 09 (Green) 10

11 12

RJ45-4 13 (Brown) 14

15 16

DKPDKPDKP

DKP Blue - (Blue & White)DKP Orange - (Orange & White)DKP Green - (Green & White)DKP Brown - (Brown & White)

DKP Blue - (Blue & White)DKP Orange - (Orange & White)DKP Green - (Green & White)DKP Brown - (Brown & White)

DKP Blue - (Blue & White)DKP Orange - (Orange & White)DKP Green - (Green & White)DKP Brown - (Brown & White)

L1 L2

1

2

3

4

Connector Port Colour

RJ45-1 SLT 01 (Blue) 02

03 04

RJ45-2 05 (Orange) 06

07 08

RJ45-3 09 (Green) 10

11 12

RJ45-4 13 (Brown) 14

15 16

Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

RJ45-5 DKP 01 Blue - (Blue & White)(Gray) DKP 02 Orange - (Orange & White)

RJ45-6 TRK 01 Blue - (Blue & White)(Red) TRK 02 Orange - (Orange & White)

TRK2, DKP2, SLT16 Card

5

6

Page 45: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

L1 L2

1

2

3

4

TRK4, SLT16 Card

5

6

Connector Port Colour

RJ45-1 SLT 01 (Blue) 02

03 04

RJ45-2 05 (Orange) 06

07 08

RJ45-3 09 (Green) 10

11 12

RJ45-4 13 (Brown) 14

15 16

Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

RJ45-5 TRK 01 Blue - (Blue & White)(Gray) TRK 02 Orange - (Orange & White)

RJ45-6 TRK 03 Blue - (Blue & White)(Red) TRK 04 Orange - (Orange & White)

L1 L2

1

2

3

4

DKP4, SLT16 Card

5

6

Connector Port Colour

RJ45-1 SLT 01 (Blue) 02

03 04

RJ45-2 05 (Orange) 06

07 08

RJ45-3 09 (Green) 10

11 12

RJ45-4 13 (Brown) 14

15 16

Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

RJ45-5 DKP 01 Blue - (Blue & White)(Gray) DKP 02 Orange - (Orange & White)

RJ45-6 DKP 03 Blue - (Blue & White)(Red) DKP 04 Orange - (Orange & White)

Page 46: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

L1 L2

1

2

3

4

SLT20 Card

5

6

Connector Port Colour

RJ45-1 SLT 01 02 03 04

RJ45-2 05 06 07 08

RJ45-3 09 10 11 12

RJ45-4 13 14 15 16

Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

SLT Blue - (Blue & White)SLT Orange - (Orange & White)SLT Green - (Green & White)SLT Brown - (Brown & White)

RJ45-5 SLT 17 Blue - (Blue & White)SLT 18 Orange - (Orange & White)

RJ45-6 SLT 19 Blue - (Blue & White)SLT 20 Orange - (Orange & White)

Page 47: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Following are the connection details of the 2-wire/4-wire, Type-4/Type-5

configuration:

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

One E&M Port of PBX-A One E&M Port of PBX-B

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCSNC

NC

NC

NC

NC

NC

2 Wire / Type 4 E&M Connection

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

One E&M Port of PBX-A One E&M Port of PBX-B

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

CCS Connection should be made as shown below for any of the above four combination

PLCCPanel

PLCCPanel

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

One E&M Port of PBX-A One E&M Port of PBX-B

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

4 Wire / Type 5 E&M Connection

NC

NC

NC

NC

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

One E&M Port of PBX-A One E&M Port of PBX-B

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

4 Wire / Type 4 E&M Connection

NC NC

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

One E&M Port of PBX-A One E&M Port of PBX-B

M

SB

E

SG

SP(RxA)

SP(RxB)

SP(A)

SP(B)

CCS

2 Wire / Type 5 E&M Connection

NC

NC

NC

NC

NC

NC

NC

NC

Page 48: Eternity V8 Quick Start€¦ · MDF cable for Switch Card (provided with Eternity ME only) Telephone Personality Guide Matrix Logos ... NT BC BC BC BC BC BC BC BC TE AB AB AB AB AB

Ve

rsio

n 8

, M

arc

h 2

00

9

MATRIX TELECOM PVT. LTD.

Corporate Office:

394-GIDC, Makarpura, Vadodara - 390010, India.

Tel.:+91 265 2630555, Fax: +91 265 2636598

E-mail: [email protected]

Factory:

39-GIDC, Waghodia - 391760, Dist. Vadodara, India.

Tel.: +91 2668 262056/57

Technical Support:

Tel.: +91 2668 263172/73, Fax: +91 2668 262631

E-mail: [email protected]

www.MatrixTeleSol.com