Enviro Technology Services plc

www.et.co.uk

With the largest stock of state-of-the-art environmental

monitoring equipment for hire in the UK, we can offer

just about any item from individual analysers,

portable air samplers and dust monitoring equipment

to meteorological stations and remote sensing air

pollution monitoring systems and networks.

With no capital outlay and a choice of long, medium or short-term agreements

available, it can, under certain circumstances, make sound economic sense to hire

rather than purchase. All instruments are certified to National Standard calibrations

and, from initial enquiry to delivery, you will have the confidence of dealing with

one of the most highly qualified service teams in the world.

Whether the location is a major city centre or a remote highland hill top, our

installation engineers are equipped with the latest technology, including 4-wheel

drive vehicles, to get the equipment where you want it, when you want it, set-up

and running – fast!

EnviroHire

APPLICATIONS

• Consultants

• Private industry

• Local Authorities

• Research

establishments

NEW – Enviro Technology can provide clients with a unique vehicle emissionsmonitoring survey using the Accuscan 4600 remote sensing system

Z Accuscan RSD System

Page 2: Et enviro hire leaflet

Real-time Particulate Samplers

SM200 Real-time Dust Analyser/40 filter SamplerThe SM200 can be used for both automatic dustsampling and filter sampling (up to 40 filters). The analyser conforms to both UK and EUspecifications for particulate measurement (CEN12341 approved). Available with inlet heads forTSP, PM10 and PM2.5, the SM200 is the mostflexible dust monitor available providing maximumperformance with minimal maintenance.

Specialist applications: TSP, PM10 and PM2.5.

BAM 1020 Real-time Dust AnalyserAdvanced real-time beta-attenuation particulatemonitor suitable for urban, roadside and backgroundmonitoring. Features automatic calibration checking

system, large internal data storage facility andintegral 8-channel data logger for logging othersensors, e.g. wind speed and direction. US-EPA,UK Equivalent Method*.

Specialist applications: TSP, PM10 and PM2.5.

E-SamplerThe E-Sampler is the most feature-packed light-scatter Aerosol Monitor available. Whatever yourmonitoring need the E-Sampler will provideaccurate, dependable and relevant data.

The E-Sampler is a dual technology instrument thatcombines the unequalled real-time measurement oflight scatter with the accuracy standard of filtermethods. The simple filter loading process testifiesto the seamless blending of both technologies.

Air Quality Monitoring

ET Stand-alone AnalysersContinuous gas analysers for measuring criteriapollutants, VOCs and BTX. On-line diagnostics anddata recovery with large internal storage facility.

US-EPA, MCERTS and TÜV approved. CE marked.

Specialist applications: SO2, NO, NO2, NOX, CO, O3, VOCs,Benzene, 1.3 Butadiene, H2S, N2O, NH3 and others.

ET Systems and NetworksET digital Air Quality Systems and Networks are the most advanced and flexible systems available.Utilising Integrated Digital Technology (IDT), dataretrieval is redefined and the standard for airquality monitoring systems reset.

Designed with the user in mind, ET’s systems arecompact, simple to operate, easy to maintain andare guaranteed "future-proof". A wide range ofcontinuous gas, dust and meteorological sensors isavailable and analysers and sensors can either beused together as an integrated system or as stand-alone units. Adding a new analyser is simple – justplug in to the digital RS232 switch and make aquick change in the EnviMan software.

Specialist applications: SO2, NO, NO2, NOX, CO, O3, VOCs,Benzene, 1.3 Butadiene, H2S, N2O, NH3 and others. PM10,PM2.5, TSP and meteorological sensors.

VOC AnalyserCompact design, continuous gas chromatograph PID for measuring VOCs including benzene, toluene,xylene, BTX and 1.3 butadiene. An ideal VOC analyserfor urban, roadside and background monitoring.

Specialist applications: Vinyl chloride and ethylene oxide.

EnviroHire

*Shown to meet equivalence criteria set out in the report on ‘UK equivalence programme for monitoring of particulate matter’. (See www.airquality.co.uk/archive/reports/cat05/0606130952_UKPMEquivalence.pdf)

Z BAM 1020

Z SM 200

X M200E NOx Analyser

C Aerocet 531

ET Project VManagement& Installation

Team

Page 3: Et enviro hire leaflet

Industrial Health andSafety Equipment

AerocetParticulate Mass Monitor and Particle counting in asingle unit. The 531 combines hand-held portabilitywith highly precise measurements. Data records arestored in memory and may be transferred to a PCusing the supplied software or printed using theoptional portable printer.

A remarkably flexible, higher performanceinstrument featuring:

• Operates as either a particulate counter or mass monitor

• Battery-operated, hand-held

• Two channel particle counter

• PM1, PM2.5, PM7, PM10 or Total Suspended Particulates

As a mass particular monitor, particles are detected,sized and counted in multiple size ranges. Massconversion is made using standard conversionfactors, or by using user-programmable factorsbased on unique conditions. The particle mass canbe displayed as PM1, PM2.5, PM7, PM10 or TotalSuspended Particulates.

When configured as a particle counter, size-basedparticle counts are displayed as cumulative (countsabove threshold) above 0.5 and 5.0 microns, thetwo most popular size ranges.

Particulate Sampling

MiniVol Portable Air SamplerPortable sampling device weighing less than 10kgand measuring only 50cm high, the MiniVol iscompact, rugged, battery operated and can behung from trees, poles, street lights or supportedon its own tripod.

Specialist applications: TSP, PM10 and PM2.5.

CEN 12341 Gravimetric SamplersThe single filter LVS3 (Kleinfilter) is the EU referencemethod for particulate sampling in accordance withCouncil Directive CEN EN12341. Also available, the15 filter sequential sampler is suitable for longperiods of unattended operation whilst also meetingCEN 12341. Rugged, reliable and fully EU approved,these samplers can be used for a multitude of urbanand industrial applications.

Specialist applications: Ambient air quality monitoring.

Continuous EmissionsMonitoring

ET Multi-gas Cross Duct Monitoring SystemsUsing differential optical absorption spectroscopy(DOAS), ET systems can simultaneously measure awide range of industrial pollutants in stacks, ductsor flues with no part of the system coming intophysical contact with the sample.

Specialist applications: SO2, NO, NO2, CO, CO2, NH3,VOCs, HCL and HF.

ET Compact Analysers and LD500For simple, single gas monitoring, ET CompactAnalysers represent excellent value and can be upand running within a few hours. Based on thereliable and time-proven dilution extractiontechnique, no complicated heated sample systemsare required, meaning operator maintenance andsample conditioning is kept to an absolute minimum.

The LD500 Laser Diode Analyser is a simple, cost-effective and reliable monitor using tuneablewavelength laser technology.

Specialist applications: HF, H2O, HCI, NH3, CO, CO2, H2S, O2, CH4.

ECA 450 AnalyserThe ECA 450 determines the burner efficiency offurnaces, boilers and other industrial combustionequipment helping plants reduce fuel costs whilstmonitoring and analysing pollutant levels. EPA/ETVtest verified for NOx emissions, the ECA 450 has themost user-friendly interface currently available andprovides accurate measurements of O2, CO, NO,NO2, SO2, and calculates combustion efficiency,excess air, carbon dioxide and NOx.

Specialist applications: Plant maintenance, industrialboiler/furnace servicing, energy co-ordination,compliance studies, and environmentaland Health & Safety audits.

ECA 450 Analyser V

Page 4: Et enviro hire leaflet

Vehicle EmissionMonitoring

Remote Sensing Device (RSD) -AccuscanThis quick, unobtrusive drive-by measurementsystem enables vehicle emissions to be tested “in-situ”. The main benefit of this technology isthat the motorist is not required to stop for amanual exhaust pipe test, which is labourintensive and often requires a police presence.The system's digital camera photographs eachvehicle's registration plate and advanced softwaremerges vehicle registration information with theemissions result and registration plate image. The entire process is accomplished in a fraction ofa second. RSD measures fine particulate matter(PM and PM2.5) - the most harmful pollutants indiesel exhaust with greater accuracy than basicopacity testing. RSD also measure carbonmonoxide, hydrocarbons and nitrogen in dieselexhaust.

Housings andEnclosures

Mobile and StaticA wide range of systems housings, from roadsidecabinets and mobile trailers to permanent, fully-air conditioned enclosures is offered.

Housings can be customised to meet individualoperational requirements including anti-vandal,high security features; structures designed toblend with existing surroundings and/or complywith local planning restrictions; and units tosatisfy specific Health and Safety regulations.

Indoor Air Quality

GraywolfGraywolf's DirectSense provides Indoor Air Qualityusing software, interface and sensor technologythat unleashes the power of Microsoft MobileWindows Pocket PCs, as well as Notebook, Tabletand Laptop computers for accurate, easy, efficient,upgradeable, thoroughly documented monitoring.Application tips, industry documents and anextremely intuitive user interface are loaded on themobile PC. Detailed data collection and reportinghas never been easier. Graywolf also manufacturesClassical Line Instruments for IAQ, IH, HVAC, ∆Pand other applications.

The DirectSense IAQ monitor from Graywolf makesproactive indoor air quality surveys efficient andeasy to conduct. Optimise the balance betweenfacility energy efficiency and occupant health andcomfort. Identify potential IAQ issues before theybecome problems and respond immediately tocomplaints with the most advanced, most accurateand most intuitive portable IAQ monitors and testinstrumentation available today.

• Measure Carbon Dioxide (dilution ventilation),Carbon Monoxide, %RH, temperature,DewPoint and more

• Options for TVOCs, particle counts, toxicgases, airflow, differential pressure and more

• Store enhanced survey information on site;data and text, drawings, audio notes andphotographs

• On-board “hand holding”: IAQ educationalmaterials, IAQ and sensor tips, governmentand industry guidelines, health effects, typicalbackground levels and more

• Add your own IAQ related procedures,documents and Word field forms for on-site use

• Extremely easy to use

• Desktop data analysis and reporting software is included

• Optional “Advanced Report Generator: IAQEdition” software makes comprehensive IAQreport generation easy and efficient.

EnviroHire

www.et.co.uk

Monitoring for Life

EnviroTechnology Services plcAdvanced Environmental Systems - Sales, Hire and Services

Kingfisher Business Park, London Road, Stroud, Gloucestershire, GL5 2BYTel: +44 (0)1453 733200 Fax: +44 (0)1453 733201 Email: [email protected]