espan 340™ / 470™d1ki6btnkpblpf.cloudfront.net/1001/rrep_residential-roof... · 2015. 8....

29
RESIDENTIAL ROOFING Espan 340™ / 470™ 0800 ROOFNZ (0800 766 369) www.metalcraftroofing.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] RREP 00 / 00 COVER SHEET 01 / 24 ROOF RIDGE 01A / 24 RIDGE FLASHING ALTERNATIVE OPTION 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH INTERNAL GUTTER BRACKET 08 / 24 EAVE WITH SNOW STRAP 09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET 10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET 10A / 24 EAVE FLASHING ALTERNATIVE OPTION 11 / 24 BARGE WITH PROFILED CLADDING 12 / 24 BARGE OVERHANG 12A / 24 BARGE FLASHING ALTERNATIVE OPTIONS 13 / 24 PARAPET WITH TRANSVERSE APRON 14 / 24 TRANSVERSE APRON 14A / 24 TRANSVERSE APRON ALTERNATIVE OPTION 15 / 24 PARALLEL APRON 16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION 17 / 24 OVER 85mm DIAMETER PIPE PENETRATION 18 / 24 3D RIDGE TO BARGE JUCTION 19 / 24 3D DUTCH GABLE 20 / 24 3D APRON 21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION 22 / 24 3D CHIMNEY PENETRATION 23 / 24 3D RIDGE/BARGE FLASHINGS 24 / 24 3D DUTCH GABLE FLASHINGS DETAIL LIST

Upload: others

Post on 30-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • RESIDENTIAL ROOFING

    Espan 340™ / 470™

    0800 ROOFNZ (0800 766 369)www.metalcraftroofing.co.nz

    Architectural / Specification EnquiriesPh: 09 274 0408

    Mobile: 027 603 1096Email: [email protected]

    00 / 00 COVER SHEET01 / 24 ROOF RIDGE01A / 24 RIDGE FLASHING ALTERNATIVE OPTION02 / 24 SAWTOOTH RIDGE03 / 24 SAWTOOTH EAVE04 / 24 ROOF VALLEY05 / 24 ROOF - CHANGE PITCH06 / 24 EAVE WITH METALLINE FASCIA07 / 24 EAVE WITH INTERNAL GUTTER BRACKET08 / 24 EAVE WITH SNOW STRAP09 / 24 FLUSH EAVE WITH INTERNAL GUTTER BRACKET10 / 24 FLUSH EAVE WITH EXTERNAL GUTTER BRACKET10A / 24 EAVE FLASHING ALTERNATIVE OPTION11 / 24 BARGE WITH PROFILED CLADDING12 / 24 BARGE OVERHANG12A / 24 BARGE FLASHING ALTERNATIVE OPTIONS13 / 24 PARAPET WITH TRANSVERSE APRON14 / 24 TRANSVERSE APRON14A / 24 TRANSVERSE APRON ALTERNATIVE OPTION15 / 24 PARALLEL APRON16 / 24 MAX. 85mm DIAMETER PIPE PENETRATION17 / 24 OVER 85mm DIAMETER PIPE PENETRATION18 / 24 3D RIDGE TO BARGE JUCTION19 / 24 3D DUTCH GABLE20 / 24 3D APRON21 / 24 3D OVER 85mm DIAMETER PIPE PENETRATION22 / 24 3D CHIMNEY PENETRATION23 / 24 3D RIDGE/BARGE FLASHINGS24 / 24 3D DUTCH GABLE FLASHINGS

    DETAIL LIST

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    PRE-FINISHED RIDGE CAP FLASHING

    STOPENDS TO ROOF CLADDING

    ROOF FRAMING

    PURLIN

    METALCRAFT ESPAN™ROOFING

    PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mmSCREWS

    BUILDING PAPERSHOWN DASHED

    15.0

    X

    NOTCHED EDGE OVERESPAN™ RIBS. REFERTO SHEET NO. 01A/24FOR ALTERNATIVEOPTION.

    5mm

    GAP 5m

    m G

    AP

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    X

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 130mm

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    PRE-FINISHED RIDGE CAP FLASHING

    STOPENDS TO ROOF CLADDING

    ROOF FRAMING

    PURLIN

    METALCRAFTESPAN™ROOFING

    METALCRAFT ESPAN™CLIP SYSTEM WITH 12Gx 35mm SCREWS

    BUILDING PAPERSHOWN DASHED

    15.0

    PRE-FINISHED POP RIVETBEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW

    PRE-FINISHED 'T' SHAPEFLASHING. NOTCHEDOVER ESPAN™ RIBS

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    X

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 130mm

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°PRE-FINISHED

    SAWTOOTH RIDGE CAPFLASHING.

    STOPENDS TO ROOF CLADDING

    BUILDING PAPER SHOWNDASHED

    PURLIN

    PRE-FINISHED 8g WAFER-TEKSCREW BEDDED IN SILICONE

    METALCRAFT ESPAN™CLIP SYSTEM WITH 12Gx 35mm SCREWS

    ROOF OR WALLFRAMING

    TIMBER PACKER

    FASCIA BOARD

    WEATHERBOARDS ON CAVITY

    BUILDING PAPER SHOWN DASHED

    PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    METALCRAFT ESPAN™ ROOFING

    5 GAP

    20

    15

    ALTERNATIVE OPTIONBIRDS BEAK EDGE

    15.0

    Z

    X

    5mm

    GAP

    HEMMED EDGE

    NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO.01A/24 FOR ALTERNATIVE OPTION.

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    MIN. 50mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    MIN. 70mm

    X

    Z

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm

    MIN. 90mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 130mm

    MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    TIMBER FASCIA

    SOFFIT LINING

    METALCRAFT ESPAN™ ROOFING

    BUILDING PAPER SHOWN DASHED

    PURLIN

    PRE-FINISHED SAWTOOTHRIDGE CAP FLASHING

    METALCRAFT ESPAN™CLIP SYSTEM WITH12G x 35mm SCREWS

    ROOF FRAMING

    PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    15.0

    0°X

    Z

    PRE-FINISHED 8g WAFER-TEKSCREW BEDDED IN SILICONE

    5mm

    GAP

    5 GAP

    20

    15

    ALTERNATIVE OPTIONBIRDS BEAK EDGE

    HEMMED EDGE

    STOPENDS TO ROOFCLADDING

    NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO.01A/24 FOR ALTERNATIVE OPTION.

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    MIN. 50mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    MIN. 70mm

    X

    Z

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm

    MIN. 90mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 130mm

    MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • ROOF FRAMING

    PURLIN

    METALCRAFT ESPAN™ROOFING

    METALCRAFT ESPAN™CLIP SYSTEM WITH 12G x35mm SCREWS

    BUILDING PAPER CONTINUOUSUNDER GUTTER IF COPPER BASEDTREATMENTS ARE USED

    VALLEY BOARD

    PREFINISHED VALLEY GUTTER

    MIN

    . 50m

    m

    CC

    B : CLEARANCE BETWEEN ROOFING

    A : OVERALL VALLEY GUTTER WIDTH

    MIN

    . 20mm

    SITUATION 1

    MAX. CATCHMENT 25m²MIN. ROOF PITCH 8°

    MIN. 250mm

    MIN. 50mm

    MIN. 80mm

    SITUATION 2

    MAX. CATCHMENT 16m²MIN. ROOF PITCH 12.5°

    160mm - 249mm

    MIN. 40mm

    MIN. 60mm

    A

    B

    C

    PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012 AND E2 FORFURTHER INFORMATION.

    * ROOF PITCH FOR VALLEYS AS PER E2.

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    ROOF VALLEY

    04 / 242014

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    PURLIN

    METALCRAFT ESPAN™ROOFING

    METALCRAFT ESPAN™CLIP SYSTEM WITH 12G x35mm SCREWS

    PURLIN

    ROOF FRAMING

    PRE-FINISHED CHANGE OF ROOFPITCH FLASHING

    BUILDING PAPERCONTINUOUS OVERFLASHING SHOWN DASHED

    BUILDING PAPER CONTINUOUSUNDER FLASHING SHOWN DASHED

    45.0

    0°10

    .00°

    MIN. 250mm

    CLEARANCE

    MIN. 10mm

    X

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    STST OR GALV. FLAT HEADNAIL FOR FLASHING

    NOTCHED EDGE OVERESPAN™ RIBS. REFER TOSHEET NO.01A/24 FORALTERNATIVE OPTION.

    5mm

    GAP

    PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW

    METALCRAFT ESPAN™ ROOFING.STOPENDS TO ROOF CLADDING

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    X

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 200mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 130mm

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    STST OR GALV. FLAT HEAD NAIL

    METALCRAFT ESPAN™ROOFING

    PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.

    BUILDING PAPER SHOWNDASHED

    METALLINE™ FASCIA

    FASCIA BRACKET

    SOFFIT LINING

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mmSCREWS

    METALLINE™ QUAD GUTTER

    METALLINE™ QUAD GUTTEROVERSTRAP

    TIMBER ROOF FRAMING

    15.00°

    OVE

    RLA

    P

    MIN

    . 35m

    m

    OR AS REQU

    IREDMIN. 5

    0mm

    MIN. 125 mm

    SPRING CLIP

    EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    EAVE WITH METALLINE FASCIA

    06 / 242014

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    TIMBER FASCIA

    METALLINE™ QUAD GUTTER

    METALLINE™ QUAD GUTTERINTERNAL BRACKET

    15.00°

    SOFFIT LINING

    TIMBER ROOF FRAMING

    METALCRAFT ESPAN™ROOFING

    BUILDING PAPER SHOWNDASHED

    OR AS REQU

    IREDMIN. 5

    0mm

    MIN. 125 mm

    OVE

    RLA

    P

    MIN

    . 35m

    mTIMBER PURLIN

    PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    STST OR GALV. FLAT HEAD NAIL FORFLASHING

    PRE-FINISHED 8g WAFER-TEK SCREW

    EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    EAVE WITH INTERNAL GUTTER BRACKET

    07 / 242014

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    TIMBER FASCIA

    METALLINE™ QUAD GUTTER

    METALLINE™ QUAD GUTTERINTERNAL BRACKET

    15.00°

    SOFFIT LINING

    TIMBER ROOF FRAMING

    METALCRAFT ESPAN™ROOFING

    BUILDING PAPER SHOWNDASHED

    OVE

    RLA

    P

    MIN

    . 35m

    mTIMBER PURLIN

    REFER TO SHEET NO.10A/24FOR ALTERNATIVE FLASHINGOPTION.

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    STST OR GALV. FLAT HEAD NAIL FORFLASHING

    OR AS REQU

    IREDMIN. 5

    0mm

    MIN. 125 mm

    SNOW STRAP AS REQUIRED

    PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    PRE-FINISHED 8g WAFER-TEK SCREW

    EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    EAVE WITH SNOW STRAP

    08 / 242014

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    TIMBER PACKER

    FASCIA BOARD

    TIMBER PACKER

    WEATHERBOARDS ON CAVITY

    BUILDING PAPER SHOWN DASHED

    ROOF FRAMING

    15.00°

    METALCRAFT ESPAN™ROOFING

    BUILDING PAPER SHOWNDASHED

    OVE

    RLA

    P

    MIN

    . 35m

    mTIMBER PURLIN

    PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    STST OR GALV. FLAT HEAD NAIL FORFLASHING

    OR AS REQU

    IREDMIN. 5

    0mm

    MIN. 125 mm

    QUARTER ROUND GUTTER

    QUARTER ROUND GUTTERINTERNAL BRACKET

    PRE-FINISHED 8g WAFER-TEK SCREW

    EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    FLUSH EAVE WITH INTERNAL GUTTER BRACKET

    09 / 242014

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    TIMBER PURLIN

    PRE-FINISHED EAVE FLASHING.REFER TO SHEET NO.10A/24 FORALTERNATIVE FLASHING OPTION.

    QUARTER ROUND GUTTER

    QUARTER ROUND GUTTEREXTERNAL BRACKET METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    15.00°

    METALCRAFT ESPAN™ROOFING

    BUILDING PAPER SHOWNDASHED

    TIMBER PACKER

    FASCIA BOARD

    TIMBER PACKER

    WEATHERBOARDS ON CAVITY

    BUILDING PAPER SHOWN DASHED

    ROOF FRAMING

    OVE

    RLA

    P

    MIN

    . 35m

    m

    STST OR GALV. FLAT HEAD NAIL FORFLASHING

    OR AS REQU

    IREDMIN. 5

    0mm

    MIN. 125 mm

    PRE-FINISHED 8g WAFER-TEK SCREW

    EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    FLUSH EAVE WITH EXTERNAL GUTTER BRACKET

    10 / 242014

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    TIMBER FASCIA

    BOX GUTTER 125 WITHEXTERNAL BRACKET

    15.00°

    SOFFIT LINING

    TIMBER ROOF FRAMING

    METALCRAFT ESPAN™ROOFING BUILDING PAPER SHOWNDASHED

    MIN. 125mm

    STST OR GALV. FLAT HEADNAIL FOR FLASHING

    PRE-FINISHED EAVE FLASHINGALTERNATIVE OPTION

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    TIMBER PURLIN

    PRE-FINISHED 8g WAFER-TEK SCREW

    OVE

    RLA

    P

    MIN

    . 35m

    m

    OR AS REQU

    IREDMIN. 5

    0mm

    EAVE FLASHING REQUIRED WHEN- ROOF PITCH ≤ 10°, OR- SOFFIT WIDTH ≤ 100mm, OR- WIND ZONES = VERY HIGH OR EXTRA HIGH OR- ENGINEER SPECIFIC DESIGN

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 2

    EAVE FLASHING ALTERNATIVE OPTION

    10A / 242014

  • TIMBER PACKER

    BARGE BOARD

    BUILDING PAPERSHOWN DASHED

    PURLIN

    WEATHERBOARDSON CAVITY

    BUILDING PAPER SHOWNDASHED

    PRE-FINISHED 12gx55mmWAFER-TEK WITH WASHER

    ROOF FRAMING

    TIMBER PACKER

    PRE-FINISHED BARGEFLASHING BRACKETSFIXED WITH PRE-FINISHED COUNTERSUNK 8g WAFER-TEKSCREW

    Z

    METALCRAFT ESPAN™ ROOFING

    PRE-FINISHED BARGE FLASHING WITH SECRETGUTTER. REFER SHEET NO.12A/24 & 12B/24 FORALTERNATIVE FLASHING OPTIONS

    PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW

    5mm

    GAP

    FOR SET OUT TO BE SYMMETRICAL

    THIS DIMENSION TO BE EQUAL ON BOTH SIDES OF ROOF BARGE

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 50mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 70mmZ

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 90mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • METALCRAFT ESPAN™ ROOFING

    FLY RAFTER

    PRE-FINISHED BARGEFLASHING BRACKETS FIXEDWITH PRE-FINISHEDCOUNTER SUNK 8g WAFER-TEK SCREW

    BARGE BOARD

    BUILDING PAPER SHOWNDASHED

    PURLIN

    SOFFIT LINING

    PRE-FINISHED BARGE FLASHING WITH SECRETGUTTER. REFER SHEET NO.12A/24 & 12B/24 FORALTERNATIVE FLASHING OPTIONS

    PRE-FINISHED 12gx55mmWAFER-TEK WITH WASHER

    5mm

    GAP

    Z

    PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

    FOR SET OUT TO BE SYMMETRICAL

    THIS DIMENSION TO BE EQUAL ON BOTH SIDES OF ROOF BARGE

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 50mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 70mmZ

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 90mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • 5mm

    GAP

    25 mm

    METALCRAFT ESPAN™ ROOFING

    FLY RAFTER

    PRE-FINISHED BARGEFLASHING BRACKETS FIXEDWITH PRE-FINISHED COUNTERSUNK 8g WAFER-TEK SCREW

    BARGE BOARD

    BUILDING PAPER SHOWN DASHED

    PURLIN

    SOFFIT LINING

    PRE-FINISHED 12gx55mmWAFER-TEK WITH WASHER

    PRE-FINISHED POP RIVET BEDDED IN SILICONE ORPRE-FINISHED 8g WAFER-TEK SCREW

    Z

    FOR SET OUT TO BE SYMMETRICAL

    THIS DIMENSION TO BE EQUAL ON BOTH SIDES OF ROOF BARGE

    PRE-FINISHED BARGE FLASHING WITHSECRET GUTTER. REFER SHEET NO.12/24 &12B/24 FOR ALTERNATIVE FLASHING OPTIONS

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 50mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 70mmZ

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 90mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    TIMBER PACKER

    FASCIA BOARD

    WEATHER-BOARDON CAVITY

    BUILDING PAPERSHOWN DASHED

    PRE-FINISHED PARAPETCAP FLASHING

    TIMBER PACKER

    BUILDING PAPER TO PROVIDESEPARATION OF METAL CAPPINGAND TIMBER SHOWN DASHED

    PURLIN

    PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    METALCRAFT ESPAN™ ROOFING

    BUILDING PAPER SHOWN DASHED

    15.0

    0°WALL FRAMING ROOF FRAMING

    TIMBER NOG FORFIXING APRONFLASHING

    CONTINUOUS TIMBER PACKING

    MIN

    . 5.0

    Z

    GN

    L

    STST OR GALV.FLAT HEAD NAILFOR FLASHING

    PRE-FINISHEDSELFDRILLING/TAPPINGSCREW WITHRUBBER WASHER

    PRE-FINISHED 8gWAFER-TEK SCREWBEDDED INSILICONE

    5mm

    GAP

    PRE-FINISHED APRON FLASHING.NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO. 01A/24FOR ALTERNATIVE OPTION.

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 35mm

    MIN. 75mm

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    MIN. 50mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    MIN. 70mm

    G

    N

    L

    Z

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    MIN. 200mm

    MIN. 90mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    25mm

    MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

    MIN. 150mm

    MIN. 50mm(VERTICALLY DOWN FACE - SMOOTH)MIN. 75mm(VERTICALLY DOWN FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    15.0

    GN

    L

    5mm

    GAP

    STOPENDS TO ROOF CLADDING

    ROOF FRAMING

    BUILDING PAPER SHOWNDASHED

    PVC CAVITY CLOSER

    WALL CLADDING ON CAVITY

    CANT STRIP PACKER

    NOG FOR FIXING APRONFLASHING

    STST OR GALV. FLAT HEADNAIL FOR FLASHING

    METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 35mm SCREWS METALCRAFT ESPAN™ ROOFING

    PRE-FINISHED POP RIVETBEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    PRE-FINISHED APRONFLASHING

    EXTRA BUILDING PAPER OVERFLASHING SHOWN DASHED

    PURLIN NOTCHED EDGE OVER ESPAN™RIBS. REFER TO SHEET NO. 14A/24FOR ALTERNATIVE OPTION.

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 35mm

    MIN. 75mm

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    G

    N

    L

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    MIN. 200mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    25mm

    MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

    MIN. 150mm

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • * ESPAN™ 340 MIN. ROOF PITCH = 3°

    15.0

    GN

    STOPENDS TO ROOF CLADDING

    ROOF FRAMING

    BUILDING PAPER SHOWNDASHED

    PVC CAVITY CLOSER

    WALL CLADDING ON CAVITY

    CANT STRIP PACKER

    NOG FOR FIXING APRONFLASHING

    STST OR GALV. FLAT HEADNAIL FOR FLASHING

    METALCRAFT ESPAN™ CLIPSYSTEM WITH 12G x 35mm SCREWS

    METALCRAFT ESPAN™ ROOFING

    PRE-FINISHED SECONDARYFLASHING NOTCHED OVERESPAN™ RIBS

    PRE-FINISHED APRON FLASHINGALTERNATIVE OPTION

    EXTRA BUILDING PAPER OVERFLASHING SHOWN DASHED

    PURLIN

    PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

    L

    5mm

    GAP

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 35mm

    MIN. 75mm

    MIN. 130mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    MIN. 200mm(EXCLUDDING ANY SOFT EDGE ORTURN-DOWN TO ROOFING)

    G

    N

    L

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    MIN. 200mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    25mm

    MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

    MIN. 150mm

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • PRE-FINISHED 12gx55mm WAFER-TEK WITH WASHER

    PRE-FINISHED APRON SECRETGUTTER FLASHING PRE-FINISHED POP RIVET

    BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    PURLIN

    GN

    PRE-FINISHEDAPRON FLASHING

    WEATHERBOARDS WALLCLADDING ON CAVITY

    CANT STRIP PACKER

    BUILDING PAPER OVERFLASHING SHOWN DASHED

    STST OR GALV. FLATHEAD NAIL FORFLASHING

    NOG FOR FIXINGAPRON FLASHING

    PVC CAVITY CLOSER

    METALCRAFT ESPAN™ROOFING

    HEM PRE-FINISHEDFLASHING TO EDGE

    BUILDING PAPER SHOWNDASHED

    5mm

    GAP

    ROOF FRAMING

    REFER SHEET NO.12B/24 FORALTERNATIVE FLASHING OPTIONS

    SITUATION 1

    1. LOW, MEDIUM, HIGH WIND ZONES2. ROOF PITCH ≥ 10°

    MIN. 35mm

    MIN. 75mm

    SITUATION 2

    1. VERY HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    G

    N

    SITUATION 3

    1. EXTRA HIGH WIND ZONE2. ALL ROOF PITCHES

    MIN. 35mm

    MIN. 75mm

    PLEASE REFER TO E2 FOR FURTHER INFORMATION ON FLASHING COVER WIDTHS.

    CATEGORY A

    1. NORMAL EXPOSURE2. ROOF PITCH >10°

    25mm

    MIN. 50mm + HEM OR 75mm(VERTICALLY UP FACE - SMOOTH)MIN. 75mm + HEM OR 100mm(VERTICALLY UP FACE - PROFILED)

    CATEGORY B

    1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH

  • METALCRAFT ESPAN™ ROOFING

    EPDM FLEXIBLE CONE SLEEVE

    MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.

    TIMBER PURLIN

    BUILDING PAPER SHOWN DASHED

    THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.10°and MAX. 45°- PIPE DIAMETER MAX. 85mm

    METALCRAFT ESPAN™ ROOFING

    PIPE (PIPE DIAMETER ≤ 85mm)

    EPDM FLEXIBLE CONE SLEEVE

    BUILDING PAPER SHOWN DASHED

    MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN.REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.

    TIMBER PURLIN

    15.00°

    * MIN. 10° FOR PIPE PENETRATION

    ROOF FRAMING

    ROOF FRAMING

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 5

    MAX. 85mm DIAMETER PIPE PENETRATION

    16 / 242014

  • PRE-FINISHED SOAKER FLASHING UNDERPRE-FINISHED ROOF RIDGE FLASHING.REFER SHEET NO.12/24 & 12B/24 FORALTERNATIVE FLASHING OPTIONS.

    PIPE (85mm > PIPE DIAMETER ≤ 500mm)

    EPDM FLEXIBLE CONE SLEEVE

    MALLEABLE FLANGE, SCREW OR RIVET FIXED,AND SEALED TO ROOFING PROFILE. FITNEOPRENE WASHERS TO ALL SCREW FIXINGS.FITTED ON 45° ANGLE IN PLAN. REFER TO MRMCODE OF PRACTICE VERSION 2 2/2012.

    PRE-FINISHED SOAKER FLASHING WITHESPAN SECRETE GUTTER FLASHING.REFER SHEET NO.12,12A&12B/24 FORALTERNATIVE FLASHING OPTIONS.

    PURLIN

    BUILDING PAPER SHOWN DASHED

    THIS DETAIL IS APPLIED ONLY WHEN- ROOF PITCH MIN.10°- PIPE DIAMETER OVER 85mm AND MAX. 500mm- PIPE TO BE POSITIONED AS CLOSE TO ROOF RIDGEAS POSSIBLE

    PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

    PURLIN

    ROOF FRAMING

    ROOF FRAMING

    PRE-FINISHEDROOF RIDGEFLASHING

    METALCRAFTESPAN™ROOFING

    X

    L

    5mm

    GAP

    5mm

    GAP

    NOGS BETWEEN PURLINS FOR PENETRATION

    15.00°* MIN. 10° FOR PIPE PENETRATION

    REFER TO SHEET NO. 14/24 TRANSVERSE APRON

    REFER TO SHEET NO. 16/24 PARALLEL APRON

    REFER TO SHEET NO. 01/24 ROOF RIDGE

    L

    M

    X

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP

    - BUILDING PAPER IS THE COMMON GENERIC NAME FOR PERMEABLEROOF AND WALL UNDERLAYS. PLEASE REFER TO NZBC E2/AS1 ANDMRM CODE OF PRACTICE VERSION 2.2 /2012.

    * - PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2 /2012 AS MINIMUM PITCH WILL INCREASE DEPENDING ON SHEET LENGTH.

    ScaleDate Sheet 1 : 5

    OVER 85mm DIAMETER PIPE PENETRATION

    17 / 242014

  • PRE-FINISHED RIDGE CAPFLASHING

    METALCRAFT ESPAN™ROOFING

    METALCRAFT ESPAN™ROOFING BARGE FLASHINGWITH SECRET GUTTER. REFERTO SHEET NO.12/24

    PURLIN

    ROOF FRAMING

    FASCIA BOARD

    WALL CLADDING ON CAVITY

    WALL FRAMING

    * PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D RIDGE TO BARGE JUCTION

    18 / 242014

  • PRE-FINISHED RIDGE FLASHING

    METALCRAFT ESPAN™ ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

    PRE-FINISHED BARGE FLASHING

    PRE-FINISHED APRONFLASHING

    PRE-FINISHED HIP FLASHING

    GUTTER

    FASCIA BOARD

    * PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

    WALL CLADDING ON CAVITY

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D DUTCH GABLE

    19 / 242014

  • GUTTER

    METALCRAFT ESPAN™ ROOFINGTURN DOWN INTO GUTTERREFER TO EAVE DETAILS FORMINIMUM ROOF OVERHANG

    WALL CLADDING ON CAVITY

    PRE-FINISHED APRON FLASHINGWITH SECRET GUTTER. REFERTO SHEET NO.15/24

    PRE-FINISHED APRON DIVERTER

    WALL CLADDING ON CAVITY

    * PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHER INFORMATIONON FLASHING COVER WIDTHS.

    FASCIA BOARD

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D APRON

    20 / 242014

  • PRE-FINISHED SOAKER FLASHING

    EPDM FLEXIBLE CONE SLEEVE

    MALLEABLE FLANGE, SCREW ORRIVET FIXED, AND SEALED TOROOFING PROFILE. FIT NEOPRENEWASHERS TO ALL SCREWFIXINGS. FITTED ON 45° ANGLE INPLAN. REFER TO MRM CODE OFPRACTICE VERSION 2 2/2012.

    PRE-FINISHED ROOF RIDGEFLASHING

    PIPE(85mm < PIPE DIAMETER ≤ 500mm)

    METALCRAFT ESPAN™ ROOFING

    METALCRAFT ESPAN™ ROOFINGBARGE FLASHING WITH SECRETGUTTER. REFER TO SHEETNO.12/24

    PRE-FINISHED SOAKER FLASHINGUNDER PRE-FINISHED ROOF RIDGEFLASHING

    * PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 ANDRANZ HOW TO ON-SITE GUIDE METALROOF FLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D OVER 85mm DIAMETER PIPE PENETRATION

    21 / 242014

  • METALCRAFT ESPAN™ROOFING TURN DOWN INTOGUTTER

    PRE-FINISHED APRONSECRET GUTTER FLASHING.REFER TO SHEET NO.15/24

    WALL CLADDING ON CAVITY

    PREFINISHED VALLEY GUTTER

    PURLINPRE-FINISHED SOAKERFLASHING

    VALLEY BOARD

    ROOF FRAMING

    MIN

    . 110

    mm

    UPS

    TAN

    D

    MIN. 110mm UPSTANDPRE-FINISHED 1.6mmALUMINIUM WELDEDSOAKER FLASHING

    * PLEASE REFER TO MRM CODE OF PRACTICE VERSION 2.2/2012AND RANZ HOW TO ON-SITE GUIDE METAL ROOF FLASHINGS FORFURTHER INFORMATION ON FLASHING COVER WIDTHS.

    DIVERTER FLASHING ONUPPER SIDE OF CHIMNEY

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D CHIMNEY PENETRATION

    22 / 242014

  • Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D RIDGE/BARGE FLASHINGS

    23 / 242014

    OPTION 1

    RIDGE CAPFLASHING

    ADDITIONALSADDLEFLASHING

    BARGEFLASHING

    RIDGE CAPFLASHING

    ADDITIONALSADDLEFLASHING

    BARGEFLASHING

    OPTION 2

    * PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.

  • (3) PRE-FINISHEDSADDLE FLASHING

    (4) PRE-FINISHEDBARGE FLASHING

    (2) PRE-FINISHEDAPRON FLASHING

    (1) PRE-FINISHED HIPFLASHING

    Reference

    DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRM codeof practice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanisms is theresponsibility of the designer. Construction detail can vary for wall cladding. The underlay is detailed as asingle line for simplicity and is indicative only. Building paper type and method of installation should complywith underlay manufacturers recommendations and NZBC regulations.

    RESIDENTIAL ROOFINGEspan 340™ / 470™

    RREP ScaleDate Sheet

    3D DUTCH GABLE FLASHINGS

    24 / 242014

    * PLEASE REFER TO MRM CODE OFPRACTICE VERSION 2.2/2012 AND RANZHOW TO ON-SITE GUIDE METAL ROOFFLASHINGS FOR FURTHERINFORMATION ON FLASHING COVERWIDTHS.