Type:ZSVInfraredGasAnalyzerInfraredGasAnalyzer
For exhaust gas measurement and R&D
ECNO:333b
A maximum 5 components out of NOX, SO2, CO, CO2, CH4, and O2 can be measured simultaneously.The large LCD screen with clear display assures simple operation.Single-beam infrared gas analyzer having excellent stability is adopted.The O2 sensor is available in 2 types: Paramagnetic type and Zirconia type.The separate structure allows the analyzer unit and the pretreatment unit to be placed separately.Measurement can be taken continuously for up to 5 days.
Compact size with excellent functionality and operabilityPortable gas analyzer with great mobility
Analyzer unit Pretreatment unit
CompactTypeCompactType
-
Simple probe or probe with primary filter
CO2: 0 to 200ppm
100%CO: 0 to 200ppm
100%NO: 0 to 500ppm
5000ppmSO2: 0 to 500ppm
1%CH4: 0 to 1000ppm
100%O2: 0 to 5% 25%Maximum range ratio 1:5 Switching between 3 ranges allowed.
Analogoutput
4 to 20mA DC or 0 to 1V DCConcentration of each component, Instantaneous value after O2 correctionOne-hour average value after O2 correction, Four-hour average value after O2 correction
Communicationfunction
RS232C (MODBUS protocol)
Repeatability 0.5%FSPower supply voltage 100 to 115V AC or 200 to 240V AC, 50/60Hz
Weight Analyzer unit: About 12kg, Pretreatment unit: About 18kg
Outsidedimensions
Analyzer unit: 204(H)x365(W)x514(D)mmPretreatment unit: 370(H)x365(W)x514(D)mm
Tests for R&D such as combustion, biogas generation, and plant photosynthesis testsSimple measurement for control of exhaust gas from businesses placeControl and check of CA storage atmosphereCombustion exhaust gas measurement controlComparison with gas analyzers installed at site and backup
Specifications Example configuration
Major applications
Zero gascalibration inlet
Gas extractor
Span gascalibration inlet
Outputsignal
Control signal (Cable connection)
NOX/SO2
Drainoutlet
Analyzerunit
Sampling unit
Supplywaterinlet
Bubbler
Mistfilter
Needlevalve
Filter
Filter Flowmeter
Detector
O2
Measurementcell
Measurementcell
FilterFilter
Power supply Power supply
NOxconverter
Flowmeter
Detector
Purgeinlet
ExhaustgasoutletSample
Pipingconnection
SamplePipingconnection
Electroniccooler
Samplegas inlet
P
P
P
CO/CO2
to us.Leave the measurement of
Display unit(LCD with backlight)
Operation key
Flow checker (for checking sample gas ow rate)
Power switch
Drain outlet
Gas extractor (option)
Sampling gas inletStandard gas inlet
Membrane lter
Bubbler(Supply water inlet)
Range select screen
Zero span screen
Menu screen
Paperless recorder for storage of measurement data and analysis
Associated equipment
Type
Number of recording points
Input signal
Storage medium
PHF3 or 64 to 20mA DC, 1 to 5V DC,thermocouple, resistance bulbCompact flash (2GB max.)
Simple probe Probe with primary filter
Simple operation assuredby clear displaySimple operation assuredby clear display
Measuredcomponent/measurementrange
Gas extractor(option)
Printed in Japan 2011-4/20FOLS
International Sales Div.Sales GroupGate City Ohsaki, East Tower, 11-2, Osaki 1-chome,Shinagawa-ku, Tokyo 141-0032, Japanhttp://www.fujielectric.comPhone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425http://www.fujielectric.com/products/instruments/
Information in this catalog is subject to change without notice.