(eq) relay and require no external eq relay. +eliminates ... · 7/14/2014  · zeftronics...

1
ZEFTRONICS Electrical Charging System Solutions CROSS REFERENCE VOLTAGE REGULATORS, ALTERNATOR & GENERATOR CONTROLLERS, STARTER GENERATOR CONTROLLERS. CURRENT &V CONTROLLER SENSORS. PARALLELING OVER CURRENT/VOLTAGE PROTECTION UNITS. LIGHT, MOTOR & TEMPERATURE CONTROLLERS, TESTERS, & TIMERS 1622 E. Whaley St, Longview, TX 75601. USA P: 888-309-3883 vvvVVV.zeftronics.com F: 903-236-9766 [email protected] 28V Twin Engine Generator Controller Units (GCU) Cross Reference Photo System Volt Amp Generator Engine Benefits / Features Approval Replacement For Aircraft Eligibility Zeftronics P/N GEN 24V 25A Delco Remy Generator Twin +Voltage Regulation: 28.4V +Current Limit: 25A +Trouble-shooting Light +Reverse Current Protection +G225EN 1 Requires separate Parallel Relay +G225KN2 Has built - in separate Parallel Relay +Prevents Regulator cycling at low RPM +Eliminates Regulator Noise FAA- PMA1 FAA- PMA2 FAA- STC2 Delco- Remy: 1118976,B, C, 1118799, 1119218, C, 1118951, 1118975 Electrodelta: VR300 - 28 - 25 Cessna: 0850460 - 8, 4, 6, 7 Beech: 35 - 380142 - 13 Lycoming: 71350, 68872 PFT/Lamar: DGR7 - 28 - 25 Cessna: 310, 310B, 310C, 310D, 310E, 310F, 310G, 310H, 3101, 310J, 310K, 320, 320A, 320B, 320 - 1. Beech: 95, B95, B95A, D95A, E95; 95 - 55, - A55, - B55, - B55A, - C55, - 055A, D55, D55A, E55, E55A. Piper: PA-23-150, PA-23- 160, PA-23-235, PA-23-250. 1 G225EN 2G225KN GEN 24V 40A Delco Remy Generator Twin +Voltage Regulation: 28.4V +Current Limit: 40A +Trouble-shooting Light +Reverse Current Protection G240EN 1 Requires separate Parallel Relay G240KN 2 Has built-in separate Parallel Relay +Prevents Regulator cycling at low RPM +Eliminates Regulator Noise FAA- PMA1 FAA- PmA: FAA-STC- Delco-Remy: 1119237 Electrodelta: VR300-28-40 PFT/Lamar: DGR7-28-40 Beech: 35-380142-15 Lycoming: 71979 Beech: 95, B95, B95A, D95A, E95; 95-55, -A55, - B55, -B55A, -055, -055A, D55, D55A, E55, E55A. Commander: 500, 500A, 500B 1 G240EN 2G240KN 1 a GEN 24V 50A Delco Remy Generator Twin +Voltage Regulation: 28.4V Current Limit: 50A +Trouble-shooting Light +Reverse Current Protection +G250EN 1 Requires separate Parallel Relay +G250KN 2 Has built-in separate Parallel Relay Prevents Regulator cycling at low RPM +Eliminates Regulator Noise FAA-PMA1 FAA- PmA: FAA-STC- Delco-Remy: 1119656 Electrodelta: VR300- 28-50 PFT/Lamar: DGR7-28- 50 Cessna: 0850460-9 Cessna: 310, 310B, 310C, 310D, 310E, 310F, 310G, 310H, 3101, 310J, 310K, 320, 320A, 320B, 320-1. Beech: 95, B95, B95A, D95A, E95; 95-55, -A55, -B55, -B55A, - C55, -055A, D55, D55A, E55, E55A. Commander: 500, 500A, 500B. Piper: PA- 23-150, PA-23-160, PA-23- 235, PA-23-250 1 G250EN 2G250KN 1 The G225EN, G240EN, G250EN are straight FAA-PMA units requiring only logbook entry when installed. They require an external paralleling (EQ) relay. 2 The G225KN, G240KN, G250KN are FAA-STC, FAA-PMA units requiring field approval with the use of FAA form 337 to install. They have built-in paralleling (EQ) relay and require no external EQ relay. Parts Cross Reference - Features, Specifications, Part Numbers, Eligibilities and Approvals may change with or without notice. Photos are for reference only, actual product may differ Date Issued 7/14/2014

Upload: others

Post on 24-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: (EQ) relay and require no external EQ relay. +Eliminates ... · 7/14/2014  · ZEFTRONICS Electrical Charging System Solutions CROSS REFERENCE VOLTAGE REGULATORS, ALTERNATOR & GENERATOR

ZEFTRONICS Electrical Charging System Solutions

CROSS REFERENCE VOLTAGE REGULATORS, ALTERNATOR & GENERATOR CONTROLLERS, STARTER GENERATOR CONTROLLERS. CURRENT &V CONTROLLER SENSORS. PARALLELING OVER

CURRENT/VOLTAGE PROTECTION UNITS. LIGHT, MOTOR & TEMPERATURE CONTROLLERS, TESTERS, & TIMERS

1622 E. Whaley St, Longview, TX 75601. USA

P: 888-309-3883 vvvVVV.zeftronics.com

F: 903-236-9766 [email protected]

28V Twin Engine Generator Controller Units (GCU) Cross Reference

Photo System Volt Amp Generator Engine Benefits / Features Approval Replacement For Aircraft Eligibility Zeftronics P/N

GEN 24V 25A Delco Remy Generator

Twin +Voltage Regulation: 28.4V +Current Limit: 25A +Trouble-shooting Light +Reverse Current Protection +G225EN 1 Requires

separate Parallel Relay +G225KN2 Has built- in

separate Parallel Relay +Prevents Regulator cycling

at low RPM +Eliminates Regulator Noise

FAA- PMA1

FAA- PMA2 FAA-STC2

Delco- Remy: 1118976,B, C, 1118799, 1119218, C, 1118951, 1118975 Electrodelta: VR300 -28-25 Cessna: 0850460-8, 4, 6, 7 Beech: 35 -380142 - 13 Lycoming: 71350, 68872 PFT/Lamar: DGR7 -28 -25

Cessna: 310, 310B, 310C, 310D, 310E, 310F, 310G, 310H, 3101, 310J, 310K, 320, 320A, 320B, 320 - 1. Beech: 95, B95, B95A, D95A, E95; 95 -55, -A55, -B55, -B55A, - C55, -055A, D55, D55A, E55, E55A. Piper: PA-23-150, PA-23- 160, PA-23-235, PA-23-250.

1 G225EN

2G225KN

GEN 24V 40A Delco Remy Generator

Twin +Voltage Regulation: 28.4V +Current Limit: 40A +Trouble-shooting Light +Reverse Current Protection • G240EN 1 Requires

separate Parallel Relay • G240KN 2 Has built-in

separate Parallel Relay +Prevents Regulator cycling

at low RPM +Eliminates Regulator Noise

FAA- PMA1

FAA- PmA: FAA-STC-

Delco-Remy: 1119237 Electrodelta: VR300-28-40 PFT/Lamar: DGR7-28-40 Beech: 35-380142-15 Lycoming: 71979

Beech: 95, B95, B95A, D95A, E95; 95-55, -A55, - B55, -B55A, -055, -055A, D55, D55A, E55, E55A. Commander: 500, 500A, 500B

1 G240EN

2G240KN

1 a

GEN 24V 50A Delco Remy Generator

Twin +Voltage Regulation: 28.4V • Current Limit: 50A +Trouble-shooting Light +Reverse Current Protection +G250EN 1 Requires

separate Parallel Relay +G250KN2 Has built-in

separate Parallel Relay • Prevents Regulator cycling

at low RPM +Eliminates Regulator Noise

FAA-PMA1

FAA- PmA: FAA-STC-

Delco-Remy: 1119656 Electrodelta: VR300- 28-50 PFT/Lamar: DGR7-28- 50 Cessna: 0850460-9

Cessna: 310, 310B, 310C, 310D, 310E, 310F, 310G, 310H, 3101, 310J, 310K, 320, 320A, 320B, 320-1. Beech: 95, B95, B95A, D95A, E95; 95-55, -A55, -B55, -B55A, - C55, -055A, D55, D55A, E55, E55A. Commander: 500, 500A, 500B. Piper: PA-23-150, PA-23-160, PA-23- 235, PA-23-250

1 G250EN

2G250KN

1 The G225EN, G240EN, G250EN are straight FAA-PMA units requiring only logbook entry when installed. They require an external paralleling (EQ) relay. 2 The G225KN, G240KN, G250KN are FAA-STC, FAA-PMA units requiring field approval with the use of FAA form 337 to install. They have built-in paralleling (EQ) relay and require no external EQ relay.

Parts Cross Reference - Features, Specifications, Part Numbers, Eligibilities and Approvals may change with or without notice. Photos are for reference only, actual product may differ Date Issued 7/14/2014