environmental monitoring

54
VOL 12.1 PRODUCTS AND SERVICES GUIDE ENVIRONMENTAL MONITORING • NON-DESTRUCTIVE TESTING REMOTE VISUAL INSPECTION • CEMS & SPECIALTY GAS Call Today! 800-242-3910

Upload: ashtead-technology

Post on 10-Mar-2016

238 views

Category:

Documents


8 download

DESCRIPTION

Ashtead Technology offers the most comprehensive fleet of environmental monitoring equipment in the industry. We specialize in carrying analyzers, detectors, monitors and samplers for environmental consultants as well as geologists performing field screening and testing. While consultants, hydrogeologists and engineers rely on us for all of their water monitoring equipment to help insure compliance with local and EPA storm water and groundwater monitoring regulations. Geologists and health and safety professionals come to Ashtead as well for our wide range of handheld meters and perimeter monitoring systems for field use at hazardous waste and construction sites when testing for pollutants and hazardous gases to protect people, processes and the environment, and to ensure appropriate regulatory compliance.

TRANSCRIPT

Page 1: Environmental Monitoring

VOL 12.1

PRODUCTS AND SERVICES GUIDEENVIRONMENTAL MONITORING • NON-DESTRUCTIVE TESTING

REMOTE VISUAL INSPECTION • CEMS & SPECIALTY GAS

Call Today!800-242-3910

Page 2: Environmental Monitoring

© 2

011,

Cas

ella

USA

, All

right

s re

serv

ed.

CASELLA BRAND SAMPLE PUMPS Intrinsically Safe

REAL TIME PARTICULATES Multi-Range Available

HEAT STRESS MONITOR Hand-Held WBGT

DATA MANAGEMENT SOFTWARE

CEL BRAND SOUND LEVEL METERS Octave & 1/3 Octave

NOISE DOSIMETERS Miniature Shoulder-Worn

CONSIDER casellausa.com800.366.2966

A Subsidiary of IDEAL INDUSTRIES, INC.

“Casella delivers easy to use instruments with exceptional

service... we should give them a call”

CEL

Page 3: Environmental Monitoring

CORPORATE HEADQUARTERS 10635 Richmond Ave., Suite 100 Houston, TX 77042 Phone 832 308 7600Fax 713 339 1823

UNITED STATES / CANADA

10201 McKalla Place, Suite EAustin, TX 78758 Phone 800 242 3910

14141 Airline Highway Oak Alley Bldg. #4, Suites P/Q Baton Rouge, LA 70817 Phone 225 610 1270 Fax 225 610 1271

If you would like more information on the product lines or services Ashtead Technology offers in addition to what you see in this catalog, please contact any of our offices listed below or visit our website at www.ashtead-technology.com.

3528-78 Avenue NW Edmonton, Alberta T6B 2X9 Phone 780 643 2680 Fax 780 468 3050

1450 Elmhurst Rd. Elk Grove Village, IL 60007 Phone 847 718 1246 Fax 847 718 1423

CEMs / Specialty Gases1474 Elmhurst Rd. Elk Grove Village, IL 60007 Toll Free 877 GAS RENT Phone 847 631 0002 Fax 847 758 2089

883 Airport Park Rd., Suite D Glen Burnie, MD 21061 Phone 410 766 2874Fax 410 766 2919

23575 Cabot Blvd., Suite 203 Hayward, CA 94545 Phone 510 732 6591 Fax 510 732 6595

10635 Richmond Ave., Suite 100 Houston, TX 77042 Phone 713 331 3924 Fax 713 331 3934

Park 100, 7144 Zionsville Rd., Bldg. 106 Indianapolis, IN 46268 Phone 317 238 3441 Fax 317 388 1124

18195 McDurmott E., Suites A/B Irvine, CA 92614 Phone 949 955 3930 Fax 949 955 3932

1016 West Eight Ave., Suite C King of Prussia, PA 19406 Phone 484 690 1001 Fax 484 690 1002

1395 S. Marietta Parkway Bldg. 100, Suite 122 Marietta, GA 30067 Phone 770 427 8533 Fax 770 427 8558

3505 Laird Rd., Unit 18 Mississauga, Ontario L5L 5Y7 Phone 905 607 9639 Fax 905 607 8592

3311 Preston Rd. Pasadena, TX 77505 Phone 281 991 1448 Fax 281 991 1449

1057 East Henrietta Rd. Rochester, NY 14623 Phone 585 424 2140 Fax 585 424 2166

2627 Metro Blvd. St. Louis, MO 63043 Phone 314 344 1079 Fax 314 344 5074

New locations are coming soon! Please check our website for more information.

Page 4: Environmental Monitoring

www.ashtead-technology.com

WHO WE ARE With offices spanning the globe, Ashtead Technology is one of the world’s leading providers of specialty inspection, testing and monitoring instrumentation. Our customers are found in industries as diverse as construction, power, manufacturing, survey, geotechnical, oil and gas and telecommunications, which means that we are accustomed to meeting tight deadlines and providing unique solutions to daily challenges.

As you will find in this Products and Services Guide, we specialize in Environmental Monitoring, Non-Destructive Testing (NDT), Remote Visual Inspection (RVI) and CEMS and Specialty Gas. We dedicate all of our resources to staying ahead of the ever advancing technologies these fields require for testing, sampling, monitoring, detecting or analyzing.

In June 2008 the management team, with backing from Phoenix Equity Partners (based London) successfully acquired the business in a management buyout from Ashtead Group plc., making Ashtead Technology a truly independent company. The Group is totally focused and committed to putting technical equipment into the hands of those who need it, either through short, medium or long term rental, as well as alternative financial offerings, including innovative programs such as our Rent To Own (RTO) and Perpetual Rental Program (PRP).

Throughout our development, we have invested heavily in our equipment – keeping the fleet up-to-date, in top condition and always ensuring that we have what you need available at short notice. Our commitment to the customer is simple – we provide technical advice on what to rent and how to use it; our availability of equipment is second to none and all our equipment is tested and ready for use.

Page 5: Environmental Monitoring

800-242-3910

THE ADVANTAGE OF RENTINGRenting is the most cost-effective way to utilize a piece of equipment without incurring all of the expenses associated with ownership, allowing your financial resources to be dedicated to your company’s core activities. Projects, deadlines and your requirements change, so it’s important to have all of the required equipment at hand. More and more organizations are switching to renting because of the economical advantages and convenience.

ASHTEAD TECHNOLOGY’S PERPETUAL RENTAL PROGRAMOur Perpetual Rental Program takes the benefits of renting even further by completely eliminating the return process. What is even better, this plan comes at a fraction of our standard monthly rate and still gives you continued access to our 24/7 technical support. Our PRP allows you to have all of the benefits of ownership and all of the advantages of renting.

RENT-TO-OWN AND SALESAshtead Technology now offers the option of rent-to-own as well as new and used equipment sales. Call us now to speak with a customer service representative about your equipment needs or visit our website for an updated list of instruments for sale.

REPAIR AND CALIBRATION SERVICEIn order for your equipment to function properly it requires routine calibration and maintenance. This process often requires your instrument to be sent back to the manufacturer, which can be expensive and cause you to be without your equipment for extended periods of time. Time you may not have. Let Ashtead Technology perform this service for you! Our factory trained technicians can diagnose and repair your equipment at our ISO: 9001 certified facility.

Page 6: Environmental Monitoring
Page 7: Environmental Monitoring

800-242-3910

2 Ambient Air Monitoring

3 Cleanroom Performance Testing

5 Confined Space Entry

8 Global Positioning

9 Hazardous Waste Investigation

11 HVAC Instruments

14 Indoor Air Quality

21 Industrial Hygiene

27 Positive Material Identification (PMI)

28 Sound, Noise & Vibration Monitoring

31 Toxic Gas Monitoring

36 Underground Location

37 Water Monitoring Instruments

43 Water Quality Instruments

44 Specialty Instruments

VTABLE OF CONTENTS

ENVIRONMENTAL MONITORING NON-DESTRUCTIVE TESTING

REMOTE VISUAL INSPECTION

CEMS

68 Videoprobes

69 Thermal Cameras

70 Pipe Inspection Cameras/Tractors

74 High Speed Video Cameras & RVI Accessories

48 Coating Inspection/Ultrasonic Thickness

50 Ultrasonic Flaw Detectors

55 ACFM

56 Eddy Current

58 Ground Penetrating Radar

59 Concrete Testing

60 Positive Material Identification (PMI)

62 Tank Inspection

63 Hardness Testers

65 Specialty Instruments

76 EPA Protocol Gases

78 Ambient Air Analyzers

81 EPA Source Analyzers NO/NO2/NOX

82 EPA Source Analyzers NO/NO2/NOX/O2/CO

83 EPA Source Analyzers NOX/SO2/CO/CO2/O2

84 EPA Source Analyzers O2/CO2

85 Total Hydrocarbon Analyzers (FID)

88 Combustion Analyzers

89 Probes, Conditioning Equipment & Accessories

APPENDIXi Metric Conversions

ii SapphIRe Library

v INNOV-X Library

vii Niton Library

x Niton XLt 898 Library

xi Glossary

xxi Category Index

xxiii Product Index Don’t miss our list of consumables on the last page of the catalog.

Page 8: Environmental Monitoring

ENV1

We specialize in renting a wide variety of analyzers, detectors, monitors and samplers for Environmental Protection and Industrial Hygiene applications.

The instruments in this section are ideal for performing clean room inspections, surveying confined space conditions, detecting and identifying potentially hazardous working environments, water quality analysis and ventilation studies.

As an added convenience to our customers, Ashtead now offers consumable items for sale as well. Should your sampling protocol require anything extra, visit our website or contact your Ashtead Technology representative for pricing details and availability.

ENVIRONMENTAL MONITORING

Page 9: Environmental Monitoring

800-242-3910

ENV 2

Samplers and Air Monitors • Tisch PM-10 Monitor, Models 6070 and 6070V• Tisch PUF High Volume Sampler Model 1000• Tisch TSP Air Sampler Models 5170 and 5170V• Met One E-Bam Mass Monitor• BGI PQ 100 The Tisch PM-10, Tisch TSP, Met One and BGI air samplers are ideal for analyzing pesticide particles, vapors and other air contaminants. Each sampler can be powered with a generator, meets EPA specifications and includes a seven day timer. Calibration kits are available. The 1000 PUF (polyurethane foam) is an easy to access sampling module with two chambers: upper for particle collection and lower for vapor entrapment. * Filters are not included with these units.

PM-10: 6070 6070V PUF 1000 TSP: 5170 5170V

Met One E-Bam BGI PQ 100

Flow Rate 36 to 44cfm 40 to 44cfm (fixed orifice) 8 to 12cfm 39 to 60cfm 42 to 44cfm (fixed orifice)

16.7 liters per minute 1.0 - 25.0 lpm

AMBIENT AIR MONITORING

Tisch PM-10, PUF 1000 ,TSP and PQ 100

Page 10: Environmental Monitoring

www.ashtead-technology.com

ENV3

Hach Particle Counters • Met One 237B, 2100, 2400, 3313, 3411, and 3445 The Hach Particle counters offer data-logging, built-in printers, six channel sizes, NIST-traceable calibration and the ability to perform Fed-Std-209E calculations. Model 237B offers six size channels and a built-in printer in one compact instrument.Use the 2100 for a rapid survey of multiple cleanroom points at a high flow rate, to test to filters in place, verify compliance of critical areas in electronic semiconductor applications and monitor LAF a benches and production tools. Model 2400 performs ISO 14644-1 calculations on all sizes (Model 3313 is a battery powered version of the 2400).Intuitive operating commands and test wizards enable the MET ONE 3445 and 3411 to reliably perform the fastest cleanroom validation testing and critical process monitoring.

237B 2100 2400/3313

3411

3445

Flow Rate Size Channels 0.1cfm 0.3, 0.5, 7.0, 1.0, 2.0, 5.0µm 1.0cfm 0.1, 0.2, 0.3, 0.5, 7.0, 1.0µm 1.0cmf 0.3, 0.5, 1.0, 3.0, 5.0, 10.0µm

1.0cmf 0.1, 0.2, 0.3, 0.5, 1.0, 5.0µm

100cmf 0.5, 1.0, 3.0, 5.0, 10.0µm

CLEANROOM PERFORMANCE TESTING

Hach Met One 3445 and 3411

Met One GT-521 and Hach Met One 227B

Handheld Particle Counters • Met One GT-521• Met One AEROCET 531• Hach Met One 227BThe GT-521 offers two simultaneous size channels and extended data storage for up to 4,000 data recordsThe AEROCET 531 provides both particle counts or mass PM measurements as stored datalogged values, real-time networked data, or printed results. The 227B offers the features and sensitivity of a larger instrument in a handheld unit. Weighing only two pounds, the 227 features a sensitivity of 0.3 microns, is fully self-contained and uses laser diode technology.

Particle Size Range: GT-521

AEROCET 531

227B

Concentration Range: Flow Rate:

Minimum Selectable: 0.3µm Maximum Selectable: 5.0µm in 0.1µm steps Two channels—0.5 and 5.0 μm

Channel 1: 00.3 µm Channel 2: from 0.5, 1.0, 3.0 or 5.0 µm

0 - 3,000,000 particles per cubic foot 0.1cfm (2.83 I/min)

Page 11: Environmental Monitoring

800-242-3910

ENV 4

Clean Air Trakker 2000 DI Water Fogger • Produces a highly visible fog using only DI water

and ultrasonic energy• Diagnose air disturbances• Delivers submicron-sized water particles at a speed

and fog density that are user-adjustable• Ideal for visualizing air flow patterns, verifying

toxic fume containment, identifying vortices and flow disturbances, verifying pressure differentials between clean zones, and tracing migration paths on walls and around furniture

• A non-contaminating fog generator is the recommended instrument for meeting the specifications of International 300mm Initiative (I300I), Semi S2-98, Semi S6-93 and Semi E44-95

Material Continuous Use Capacity

316L electro-polished stainless steel 1.5 hours at max output 2.0 liters DI water

CLEANROOM PERFORMANCE TESTING

Clean Air Trakker 2000 DI Water Fogger

BioTest RCS Plus Handheld Microbial Air Sampler

BioTest RCS Plus Handheld Microbial Air Sampler • Push-button operation, integrated display• Use this unit to evaluate the microbiological quality

of ambient air, the functionality of air treatment equipment and systems, and the effectiveness of decontamination measures

• Operation of the instrument is via a keypad with integrated, in-handle display or remote control

• Can be operated in either a vertical or horizontal position

• Simple to operate: fit an agar media strip around the rotor, turn on the sampler and send the strip to the laboratory for analysis

Collection Principle Range of Sample Air Flow Tolerance Memory Functions Power

Airborne microorganisms impact onto agar media strip by centrifugal force 1 to 1,999 liters, optimal range volumes 10 to 1,000 liters 50 I/min ± 5% 7 pre-set volumes 3 positions in memory individually selectable Rapid-charge NiCd batteries, up to one hour operation

Page 12: Environmental Monitoring

www.ashtead-technology.com

ENV5

Innova 2 and 4 Gas Monitor and Thermo GasTech Model GT208

2 and 4 Gas Monitors • Thermo GasTech GT201 and GT402• Thermo GasTech GT208• Innova Gas Monitors The Thermo GasTech GT201 and GT402 measure hydrocarbons, oxygen, carbon monoxide and hydrogen sulfide levels. These units are intrinsically safe and meet federal regulations for pre-testing confined spaces and other remote areas. These units feature datalogging and are PC connectable. The Thermo GasTech GT208 measures two gases: carbon dioxide and oxygen. It is suitable for a wide range of CO2 monitoring applications including breweries, wineries, bioremediation and worker protection at industrial sites. It has a detection range for CO2 of either 0 to 5.00% or 0 to 20.00%.The Innova Gas Monitors are designed to detect hydrocarbons, oxygen, carbon monoxide and hydrogen sulfide in order to protect workers. Units can be configured to monitor gases in several combinations including LEL and PPM levels.

CONFINED SPACE ENTRY

RKI Eagle 1 to 6 Gas Portable Monitor

RKI Eagle 1 to 6 Gas Portable Monitor • Monitor six gases simultaneously• Built-in Data-logging• Internal pump draws samples from remote areas

Detection Principle Accuracy Safety Design Detectable Gases

Catalytic combustion, electrochemical cell, galvanic cell and infrared Maximum variance ± 5% of full scale Intrinsically Safe, Class I, Division 1, Groups A, B, C and D Hydrocarbons, oxygen, carbon monoxide, hydrogen sulfide, ammonia, arsine, carbon dioxide, chlorine, flourine, hydrogen flourine, hydrogen chloride, hydrogen cyanide, methane, nitrogen dioxide, nitric oxide, ozone, phosphine, silane, sulfur dioxide

Page 13: Environmental Monitoring

800-242-3910

ENV 6

RAE Q-RAE 4 Gas Monitor and Multi-RAE Plus

Multi-Gas Monitors • Q-RAE 4 Gas Monitor and Q-RAE Plus • Multi-RAE Plus with PID• MSA SIRIUS 4 Gas Monitor with PID The RAE gas monitors provide protection for personnel in tight, confined spaces and are intrinsically safe. Please inquire about interchangeable toxic sensors as well as their ranges and specifications. The Multi-RAE Plus includes a VOC monitor which provides continuous display and alarms for airborne VOC levels. Alarms can also be set for Short Term Exposure Levels, Time Weighted Average, peaks and minimums. An integral pump enables remote sampling. Also available is the RAE Multi-RAE IR model which features CO2 (0 to 50,000ppm) as one of the two toxic sensors. Designed as a versatile PID, the MSA SIRIUS can be configured with up to 4 additional sensors. With its real one-hand operation, it is an ideal measuring instrument as well as a personal monitor.

ALL MODELS Oxygen Combustible Gas Carbon Monoxide Hydrogen Sulfide MULTI-RAE PLUS VOCs

Range Resolution 0 to 30% 0.1% 0 to 100% LEL 1% LEL 0 to 500ppm 1ppm 0 to 100ppm 1ppm 0 to 2000ppm 0.1ppm at 0 to 200ppm 1ppm at 200 to 2000ppm

Industrial Scientific ITX-6 Multi Gas Monitor • 50ppm resolution for hydrocarbons (HC) up to the

LEL alarm set point• The unit also includes STEL and TWA readings and

alarms as well as iButton® technology (allows the operator to input user data and site information)

Sensors Operating Temp Range Operating Humidity Range Sensors Measuring Ranges and Resolution Data-logging Capability

LEL, CO, H2S, SOs, NO2, O2 (simultaneous) -20° to 50° C (-4° to 122° F), typical toxic/O2 0° to +40° C (32° to 104° F), for LEL sensor 15 - 95: RH, typical 0 - 99: RH, intermittent, non-condensing Combustible Gases/Methane: Catalytic Diffusion Oxygen and Toxic Gases: Electrochemical CO: 999ppm 1ppm H2S: 499ppm 1ppm N02: 99.9ppm 0.1ppm S02: 99.9ppm 0.1ppm 02: 30% 0.1% Comb (% LEL) 100%LEL 1%LEL Comb (%vol) 100%LEL 0.1% Vol Comb (ppm) 10,000ppm 50ppm 300 hours log time at 1 minute intervals User can configure datalogging intervals and data overwrite capability

CONFINED SPACE ENTRY

Industrial Scientific ITX 6 Multi-Gas Monitor

Page 14: Environmental Monitoring

www.ashtead-technology.com

ENV7

VRAE Hand Held 5 Gas Detector

RAE Systems VRAE Handheld 5 Gas Detector • Internal sample draw pump for quick response and

remote sampling• 48 built in correction factors for LEL sensors• 4 toxic sensor version• Sensors include the RAE dual range 0-100% volume

and 0-100% LEL• Oxygen and three, smart interchangeable toxic gas

sensors • Monitors explosive gases in an oxygen free

environment at percent by volume levels

Detector Direct Readout Sampling Pump Intrinsically Safe

Catalytic sensor for combustible gas, Thermal conductivity sensor for % volume combustible gas, Electrochemical sensors for oxygen and toxic gases Instantaneous up to 5 values, Oxygen and combustible gas as % by volume or % of LEL, Toxic gases as part per million, STEL, TWA for toxic gases, high and low values of gases, battery voltage and elapsed time Internal pump, flow rate 400cc/min, automatic shut off at low flow condition UL & cUL Class I, Division I Group A, B, C D

CONFINED SPACE ENTRY

Industrial Scientific M40 Multi-Gas Monitor

Industrial Scientific M40 Multi-Gas Monitor • Durable, user-friendly multiple gas monitor• Capable of monitoring four gas levels

simultaneously• Utilizes Electrochemical sensors • Case is immune to radio frequency

interference (RFI)

Sensors Catalytic Diffusion Electrochemical Measuring Ranges Carbon Monoxide Oxygen Hydrogen Sulfide Methane Alarms Data-logging

Hydrogen Sulfide and Methane (Combustible Gases) Oxygen and Carbon Monoxide (Toxic Gases) 0 - 999ppm in 1ppm increments 0 - 39% in 0.1% increments 0 - 500ppm in 1ppm increments 0 - 100% in 1% increments 90db audible alarm LED visual alarm Vibrating alarm for alert conditions Internal memory with capacity for 75 hours of exposure data

Page 15: Environmental Monitoring

800-242-3910

ENV 8

Trimble Pro XH Receivers The ProXH receiver introduces a new era in GPS for GIS collection. A GPS receiver, antenna and all day battery in one, the ProXH receiver delivers subfoot (<30 cm) accuracy with the revolutionary Trimble H-Star™ technology. And when high accuracy is critical to your application, add a Tornado™ antenna to your ProXH receiver for decimeter (10 cm / 4 inch) postprocessed accuracy.

The all-in-one design of the ProXH receiver means it’s simple to set up and easy to use. With a Bluetooth® wireless connection you’re cable free between the ProXH receiver and your field computer. The receiver has an integrated battery, good for a full day’s work; simply charge the battery overnight and you’re ready to go again. The ProXH receiver will last the distance, and with a rugged, waterproof casing that’s built to work where you work. When accuracy is critical for your GIS, the ProXH receiver delivers reliable subfoot performance with greater consistency at longer baselines, in tougher environments, and with shorter occupations.

GLOBAL POSITIONING

Trimble Pro XH GPS

Handheld GPS Units • Trimble Geo XH • Magellan eXplorist 500 GPS• Garmin 60cs GPS Our handheld GPS systems are ideal for electric and gas utilities, water and wastewater services, land reform projects, and other applications where on-the-spot positioning is crucial. Excavate cables and pipes without wasted effort or risk of damage to nearby assets. The Trimble Geo XH delivers the subfoot accuracy required by electric and gas utilities, water and wastewater services, land reform projects, and other applications where on-the-spot positioning is crucial. The Magellan eXplorist 500 is superior in accuracy and reliability. It features a built-in barometer, altimeter, compass and thermometer. The eXplorist includes 8MB of maps and 8MB of memory. The Garmin 60cs is an all-purpose unit, packed with features and delivers exactly what is needed in a handheld GPS. This lightweight, rugged, waterproof unit raises the bar to offer a 256-color, highly reflective display that provides easy viewing in almost any lighting condition. The unit also offers an electronic compass and barometric altimeter for highland adventures. These sensors, when combined with GPS technology, provide enhanced bearing and elevation readings.

Trimble Geo XH and Garmin 60cs

Call 800-242-3910 to request a rate schedule for any equipment seen in this catalog!Want to

know more?

Page 16: Environmental Monitoring

www.ashtead-technology.com

ENV9

UltraRAE, MiniRAE 3000 and UltraRAE 3000

RAE Systems Monitors • MiniRAE 2000 Handheld VOC Monitor• MiniRAE 3000 Handheld VOC Monitor• UltraRAE PGM-7200 Benzene Monitor• UltraRAE 3000 Benzene Monitor These intrinsically safe RAE handheld monitors are ideal for applications in industrial hygiene such as hazardous material response, confined space entry and personnel/workplace monitoring. The MiniRAE 2000 with correction factors for more than 100 chemicals. The MiniRAE 3000 PID is the most advanced handheld VOC (volatile organic compound) detector with a list of 350 compounds correction factors- more than any other PID. The UltraRAE is used to provide highly specific measurements of benzene. The UltraRAE 3000 is ideal for applications from pre-screening during refinery and plant maintenance to hazardous material response. Includes a minimum detection limit of 0.05ppm

MiniRAE 2000 MiniRAE 3000 UltraRAE

UltraRAE 3000

Range 0 to 999ppm 100 to 10,000ppm 0 to 15,000ppm 0 to 200ppm

0 to 99.99ppm

HAZARDOUS WASTE INVESTIGATION

Thermo Environmental TVA-1000B and 580B

Thermo Scientific Organic Vapor Analyzer • 580B Organic Vapor Meter• TVA-1000B Organic Vapor Analyzer These intrinsically safe vapor meters by Thermo Scientific provide fast and accurate readings of organic and inorganic vapors. Use these analyzers in applications such as detecting soil contaminants and industrial leaks or locating spills in underground storage tanks.

580B ORGANIC VAPOR METER PID TVA-1000B VAPOR ANALYZER PID FID

Range 0 to 200ppm, 200 to 2000ppm 0 to 2000ppm 0 to 50,000ppm

Page 17: Environmental Monitoring

800-242-3910

ENV 10HAZARDOUS WASTE INVESTIGATION

Photovac MicroFID

GasCheck 5000is

Ion Science Leak Detectors • GasCheck 3000• GasCheck 5000is These leak detectors are ideal for search and location of nonflammable gases such as helium, CFC’s, argon, butane, hydrogen SF6 and refrigerants. The GasCheck 5000is is intrinsically safe. The following specifications are for both the GasCheck 3000 and 5000is.

Detector Sensitivity (cc/sec) Accuracy Datalogging

Micro thermal conductivity detector (TCD) He 2x10(-5), CH4 1x10(-4), R12 1x10(-4), Ar 2x10(-4) ±5% displayed reading ± one digit 36,000 data points with date and time stamp

Flame Ionization Detectors (FID) • Photovac MicroFID• Photovac DataFID

These portable FIDs can be used to measure total VOCs (including methane) and both have either built in or Bluetooth datalogging available.

Range

Accuracy

Detection Limit Response Time Hydrogen Cylinder Discharge Time Approvals Battery Life

MicroFID DataFID 0.1 to 50,000ppm 0.1 to 100,000 ppmmethane equivalent

Within ± 0.5ppm or ± 10% actual methane concentration (0.1 to 2000ppm range)

0.5ppm methane .1 ppm methane

< 3 seconds to 90% < 3 seconds to 90%

>12 hours 70 hours

Intrinsically safe Class I, Division 1, Groups A, B, C, D

Up to 15 hours Up to 15 hours

Page 18: Environmental Monitoring

www.ashtead-technology.com

ENV11

TSI 8330 and 8340 VelociCheck®

TSI VelociCheck® Models 8330 and 8340 • Small & lightweight Air Velocity Meter• NIST traceable calibration

Air Velocity Range Instrument Operating Temp. Range Probe Operating Temp. Range Probe Dimension Battery Life Approvals Time Constant Air Velocity Accuracy

Model 8330 Model 8342 25 to 4000’/min 25 to 2000’/min 32° to 149°F 32° to 122°F 0° to 200°F 32° to 122°F 37” x .395” diameter 3.1” x .25” diameter 10hrs at 100’/min 20hrs at 100’/min Ul listed intrinsically safe for Class I, Divisions 1 and 2, Groups C and D; Class II, Groups E, F and G; and Class III when used with alkaline batteries Fast mode 3-second average, slow mode 12-second average 5.0% of reading or ±5 ft/min, whichever is greater

HVAC INSTRUMENTS

TSI 9555 VelociCalc®

TSI 9555 VelociCalc®Multi-Parameter Ventilation Meters The TSI 9555 VelociCalc® is ideal for HVAC commissioning and troubleshooting, cleanroom certification, thermal comfort studies, IAQ investigations and process air flow testing.Also available, the TSI 8386 VelociCalc® simultaneously measures and logs velocity, temperature, static pressure. Calculates volumetric flow rate, dew point, wet bulb temperature and heat flow. Multiple sensors but one easy-to-use forty-inch telescoping probe.

Measurements Air Velocity Range

Static/Differential Pressure Range

Barometric Pressure Range

Instrument Temperature Range

Data Storage Capabilities

Air Velocity Accuracy

Air velocity, temperature and relative humidity 250 to 15,500 ft/min

-15 to +15 in. H2O

20.36 to 36.648 in. Hg

40 to 113°F

26,500+ samples and 100 test IDs

±1.5% at 2,000 ft/min

TSI 9555 VELOCICALC®

Page 19: Environmental Monitoring

800-242-3910

ENV 12

TSI VelociCalc® Model 5725 Rotating Vane Anemometer • Reversible 4” (100mm) head to read supply and

exhaust flows• Calculates volumetric flow rate when user inputs

duct shape and size, or area• Sampling function records multiple point

measurements• Automatic averaging of air velocity• Simultaneously displays velocity and temperature• Sweep mode for one overall measurement• Applications include heating and cooling coil

analysis, diffuser and grille measurements, fume hood face velocity tests, indoor air quality tests, filter face velocity measurements

Velocity Range Accuracy Duct Size Range Volumetric Flow Rate Range

50 to 6,000’/min (0.25 to 30m/s) ±1.0% of reading ±4’/min (±0.02m/s) 0 to 173.6’2 (0 to 16 m2) Actual range is a function of velocity and duct area

HVAC INSTRUMENTS

TSI VelociCalc® Model 5725 Rotating Vane Anemometer

TSI AccuBalance® Model 8371

TSI AccuBalance® Model 8371 • Measures the air volume flowing through registers,

diffusers and grills• Ideal to balance an HVAC system or spot check

environments as part of indoor air quality studies• NIST traceable calibration• Input temperature and barometric pressure to

obtain an automatic conversion between actual and standard flows

Flow Range Accuracy Hood Sizes

30 to 2000cfm ± 5% of reading and ± 5cfm 24” x 24” 24” x 48” 12” x 48” 12” x 60” 36” x 36”

Page 20: Environmental Monitoring

www.ashtead-technology.com

ENV13

Shortridge ADM-870 Electronic Micromanometer

Shortridge ADM-870 Electronic Micromanometer • Designed specifically for applications with demanding air distribution requirements

such as hospitals, pharmaceutical, biological and medical research laboratories and semiconductor manufacturing cleanrooms

• 16-point averaging VelGrid provides accurate velocity readings at HEPA filters, laminar flow work stations, chemical exhaust hoods and coil banks

• Can be used in ducts as small as 2” in diameter • As accurate and sensitive as the best laboratory micromanometer• Battery powered, 2000 readings per charge

Air Velocity Range Differential Pressure Temperature Absolute Pressure Memory

25 to 3000fpm with Pitot tube 25 to 8000fpm with Pitot tube, (accuracy ± 3% of reading) 25 to 5000fpm with AirFoil probe 25 to 2500fpm with VelGrid ± 2% of reading ± 0.001 in wc from 0.0500 to 50.00 in wc, (0.0001 to 60 in wc FS); 20psid safe pressure -67.0° to 250°F, resolution 0.1°F -67.0° to 32°F, (accuracy ±1°F) 32° to 158°F, (accuracy ±0.5°F) 158° to 250°F, (accuracy ±1°F) 10 to 40 in Hg, (accuracy ±2% of reading from 14 to 40 in Hg) 100 readings, sequence labeled, sum and average

HVAC INSTRUMENTS

Page 21: Environmental Monitoring

800-242-3910

ENV 14

TSI Aerosol Monitors • TSI 8520 DustTrak®• TSI 8530 DustTrak® II• TSI 8532 DustTrak® II• TSI 8533 DustTrak® DRX• TSI SidePak®AM510 Personal Aerosol Monitor These laser photometers are ideal for indoor air quality studies, industrial workplace monitoring, evaluation of filters and engineering controls, environmental and perimeter monitoring. The 8520 DustTrak®, 8530 DustTrak®II, 8532 DustTrak®II and 8533 DustTrak® DRX are portable and battery operated. They assess aerosol concentrations of contaminants such as dust, smoke, fumes and mists by measuring particle concentrations to PM-10, PM-2.5 and PM1.0 or respirable size fractions. The TSI 8533 DustTrak DRX simultaneously measures all three. The SidePak®AM510 is a belt mounted, compact and quiet personal aerosol monitor. The AM510 is intrinsically safe, making it ideal for hazardous environments. Environmental enclosures are available for outdoor use

8520 DUSTTRAK® 8530 DUSTTRAK® II8532 DUSTTRAK® II

8533 DUSTTRAK®DRX SIDEPAK®AM510

Aerosol Concentration Range 0.001 to 20mg/m3 0.001 to 150mg/m3

0.001 to 150mg/m3

0.001 to 150 mg/m3

0.001 to 20mg/m3

INDOOR AIR QUALITY

TSI 8530 DustTrak® II and SidePak®AM510

Casella MicroDust Pro

Casella MicroDust Pro • Instantly displays dust levels and trends of airborne

fumes and aerosols• Real-time graphical display• Ideal for applications in construction/demolition,

pharmaceutical manufacturing, bakeries and mills as well as general occupational health surveys

Range Sensitivity Zero Stability Logging Intervals Operating Time

- 2.5, 0 - 25, 0 - 250, 0 - 2,500mg/m3 0.001mg/m3 +/- 0.002mg/m3 Adjustable from 1 to 600 seconds About 9hrs or 20hrs with Alkaline cells

Page 22: Environmental Monitoring

www.ashtead-technology.com

ENV15

IN USA Model AET-030 and Aeroqual 500

Ozone Monitors • Aeroqual 500• IN USA Handheld Model AET-030 These highly ozone specific monitors are ideal for applications in IAQ surveys, building investigations and monitoring plant emissions. The Aeroqual 500 includes a choice of high or low level detachable ozone sensors. This instrument is capable of datalogging up to 8,000 points. The IN USA AET-030 uses a state-of-the-art thin film semiconductor sensor. The resistance of the heated semiconductor film varies significantly in the presence of ozone due to decomposition and gas absorption.

AEROQUAL 500 Range Accuracy Response Time

0 - 2ppm (25ppm recommended maximum) <± 10% (0 - 5ppm) <± 15% (2 - 20ppm) <35 seconds

IN USA MODEL AET-030

Range Accuracy Response Time

0.01 to 10ppmv ± 0.03ppmv between 0 and 0.5ppmv, ± 30% between 0.5 and 10ppmv ~ 1 minute to 79% of value, ~ 3 minutes to 90% of value

INDOOR AIR QUALITY

N6 Microbial Sampler

Microbial Samplers • N6 Single Stage Microbial Sampler• Bioscience International SAS 180 Microbial Sampler These microbial samplers are ideal for indoor air quality studies, cleanroom efficiency studies, pharmaceutical production, animal care laboratories, food processing areas or in any environment in which contamination must be controlled. The N6 Microbial Sampler meets ACGIH specifications for bioaerosol sampling and analysis. The instrument draws an air sample into a petri dish which can be forwarded to a laboratory where microorganisms can be identified. The SAS 180 Microbial Sampler samples particles as small as 1 micron. A wide range of sample volumes can be tested over 7 hours of battery life.

Page 23: Environmental Monitoring

800-242-3910

ENV 16

TSI 8525 P-Trak Ultrafine Particle Counter • Track a particulate problem to its source• Counts particles smaller than 0.1 micrometer• Will not overload unlike conventional

particle counters• Data-logging capability

Concentration Range Particle Size Range Sample Flow Rate Battery Life Output

0.01 - 5x10° particles/cm³ 0.02 to greater than 1 micrometer 100cm³/min up to 6hrs operation at 70°F RS-232 port

INDOOR AIR QUALITY

TSI 8525 P-Trak

TSI 9306 AEROTRAK™ V2Handheld Particle Counter • Complies with all requirements of ISO 21501-4• Measures six channels of simultaneous data

6 Size Channels

Flow Rate Sample Time Data-logging Output Size Resolution Concentration Limit

6 user selectable size channels with ranges from 0.3 to 10 μm 0.1cfm 1 second to 99 hours 10,000 sample records USB and Ethernet <15% @ 0.5 μm

>2,000,000 particles/ft3 at 5% coincidence loss

TSI 9306 AEROTRAK™ V2

Page 24: Environmental Monitoring

www.ashtead-technology.com

ENV17

TSI Q-Trak Model 7565 with Optional 964 VelocityProbe

TSI Q-Trak Model 7565 with Optional 964 Velocity Probe • Real-Time simultaneous display of CO2,

temperature, relative humidity and CO• Stores 38.9 days of data at one-minute intervals• Displays 5 measurements simultaneously• User-selectable logging intervals and

start/stop times• Perform single point tests for quick building surveys

CO2 Sensor Range Accuracy CO Sensor Range Accuracy Temperature Sensor Range Accuracy Humidity Sensor Range Accuracy

Non-Dispersive Infrared (NDIR) 0 to 5000ppm ± 3% of reading and ± 50ppm Electro-chemical 0 to 500ppm ± 3% of reading or 3ppm, whichever is greater Thermometer 32° to 140°F ± 1.0°F Thin-Film Capacitive 5 to 95% RH ± 3%

INDOOR AIR QUALITY

TSI Q-Trak Model 8551 and Q-Trak Plus Model 8554

TSI Q-Trak Model 8551 and Q-Trak Plus Model 8554 • IAQ Portable Monitor with CO• Monitors Four IAQ Parameters (Carbon Dioxide,

Carbon Monoxide, Temperature and RH)• Survey and Data-logging Modes• Model 8554 Q-Trak Plus has 33 days of data-logging

memory at one-minute intervals

CO2 Sensor Range Accuracy CO Sensor Range Accuracy Temperature Sensor Range Accuracy Humidity Sensor Range Accuracy

Non-Dispersive Infrared (NDIR) 0 to 5000ppm ± 3% of reading and ± 50ppm Electro-chemical 0 to 500ppm ± 3% of reading or 3ppm, whichever is greater Thermistor 32° to 122°F ± 1.0°F Thin-Film Capacitive 5 to 95% RH ± 3%

Page 25: Environmental Monitoring

800-242-3910

ENV 18

Delmhorst Model BD 2100 and Tramex Survey Encounter

Moisture Meters • Delmhorst Model BD 2100• Tramex Survey Encounter Moisture Meter• Tramex Professional Pin-Type Moisture Meter The Delmhorst Model BD 2100 will help trace leaks, find exterior moisture intrusion and locate dry rot. Resistance technology and a clear digital readout make this instrument accurate and easy to use.The Tramex Survey Encounter Moisture Meter uses the principal of non-destructive electrical impedance to find moisture behind and underneath wood, plaster, brick, carpeting, vinyl flooring, ceramic tile and even behind drywall. This instrument contains a library of 32 wood species, three roofing types and more. The Tramex Professional Pin-Type Moisture Meter is designed to use on wood and wood products. This meter works on the principle of DC resistance to take a clear and accurate reading.

DELMHORST MODEL BD 2100 TRAMEX SURVEY ENCOUNTER TRAMEX PROFESSIONAL PIN-TYPE

Range Wood: 6 to 40% Gypsum: 0.2 to 50% Wood: 5 to 30% (Relative readings for walls, roofing and other materials) Wood: 6 to 44% (Readings above 27% are indicative only)

Vaisala Humidity and Temperature Meter Model HM34 • Accurately check temperature and relative humidity

in applications such as indoor air quality surveys and industrial monitoring and inspections

• Easy to use and fast response

Range Accuracy Resolution Response Time Battery Life

Temperature Relative Humidity -4° to 140°F 0 to 100% RH ± 0.5°F ±2% of 0 to 90% RH, ±3% at 90 to 100% RH 0.1°F 0.1% 15 seconds up to 50hrs operation

INDOOR AIR QUALITY

Vaisala Humidity and Temperature Meter Model HM34

Page 26: Environmental Monitoring

www.ashtead-technology.com

ENV19

Tramex Concrete Moisture Encounter for Flooring

Tramex Concrete Moisture Encounter for Flooring • Non-invasive meter that measures moisture in

concrete, sand/cement or gypsum screed• Operates on the principle of non-destructive

impedance measurement• During operation, a low frequency signal is

transmitted into the concrete or floor screed to measure the change in impedance caused by the presence of moisture

Range

Concrete: 2 to 6% Gypsum Floor Screed: 0 to 10%

INDOOR AIR QUALITY

ppbRAE PGM 7240 and ppbRAE 3000

RAE Systems Parts-Per-Billion PID’s • ppb PID Model PGM 7240• ppb 3000 The RAE ppb PID Model PGM 7240 uses true parts per billion detection of extremely low level, low vapor pressure and highly toxic volatile organic compounds (VOCs). This PID is perfect for the measurement of pesticide residues, low level permeation breakthrough detection, hypo-allergenic cleanroom studies or outgassing of new building materials such as carpets, fabrics or furniture. The RAE ppb 3000 is ideal for applications in HazMat detection, Homeland Security and other military protection or industrial hygiene and indoor air quality studies.

RAE ppb PID MODEL PGM 7240

Measurement Range Approvals RAE ppb 3000 Measurement Range

Approvals

0 to 999ppb at 1ppb resolution 10.0 to 9.99ppm at 0.01ppm resolution 100 to 199ppm at 1ppm resolution Intrinsically safe, UL and cUL Class I, Division 1, Groups A, B, C, D, EEx ia IIC T4 0 to 9999ppb at 1ppb resolution 10.0 to 99ppm at 0.01ppm resolution 100 to 999.9ppm at 0.1ppm resolution 1000 to 9999ppm at 1ppm resolution Intrinsically safe, UL and cUL Class I, Division 1, Groups A, B, C, D, EEx ia IIC T4

Page 27: Environmental Monitoring

800-242-3910

ENV 20

RAE Systems IAQRAE Indoor Air Quality Monitor Model PGM 5210

RAE Systems IAQRAE Indoor Air Quality Monitor Model PGM 5210 • Combines a PID with IAQ parameters (Temp, RH,

CO2 and user selected toxic gas sensor)• Built in diaphragm pump for sampling• Continuous measurement of temperature and

relative humidity

DETECTOR SPECIFICATIONS

Sampling Pump Temperature Humidity

Internal integrated diaphragm pump with programmable “duty-cycle” for PID self cleaning during long continuous run time 32° to 104°F (0 to 40°C) 0% to 95% relative humidity (non-condensing)

SENSOR SPECIFICATIONS

Gas Monitor VOCs Carbon Dioxide Carbon Monoxide Hydrogen Sulfide Sulfur Dioxide Nitric Oxide Nitrogen Dioxide Chlorine Hydrogen Cyanide Ammonia Phosphine

Range (ppm) Resolution (ppm) 0.01 to 9.99 0.01 10.0 to 99.9 0.1 100 to 500 1 0 to 20,000 10 0 to 500 1 0 to 100 1 0 to 20.0 0.1 0 to 250 1 0 to 20.0 0.1 1 to 10.0 0.1 0 to 100 1 0 to 50 1 0 to 5.0 0.1

RAE Systems AreaRAE Wireless Gas Detection System • Five-Sensor System with Built-In Modem• LEL, O2, CO, H2S, plus a PID for VOCs• Wireless communication range as far as two miles• Works with any personal computer as the

base station• Excellent for perimeter or in-plant monitoring

Sensors Oxygen Combustible gas Carbon monoxide Hydrogen sulfide Photoionization detector With 10.6 eV lamp Approvals Alarm

Range Resolution Response Time 0 to 30% 0.1% 15sec 0 to 100% LEL 1% 15sec 0 to 500ppm 1ppm 20sec 0 to 100ppm 1ppm 15sec 0 to 200ppm 0.1ppm 10sec 200 to 2000ppm 1ppm 10sec Intrinsically safe Model 5020: UL, class 1 Division II, Groups A, B, C, D Model 5010: UL, Class 1 Division 1, Groups, A, B, C, D, Class 2 Groups E, F, G hazardous locations, Temp Code T3C 100dB buzzer and flashing red LED cluster indicate exceeded preset limits, low battery or sensor failure. Separate alarm limit settings for TWA, STEL, low and high

INDOOR AIR QUALITY

RAE Systems AreaRAE Wireless Gas Detection System

Page 28: Environmental Monitoring

www.ashtead-technology.com

ENV21

Zefon Bio-Pump

Zefon Bio-Pump • Easy sampling with Air-O-Cell® and

Via-Cell® cassettes• Quiet operation and easy to read LCD screen

Flow Rate Accuracy Battery Life

15LPM ±5% About 30, 5 minute samples

INDUSTRIAL HYGIENE

Dawson 1-300, Sensidyne GilAir 5RC and SKC AirChek 52

Sampling Pumps • Sensidyne GilAir 5RC• Dawson 1-300• SKC AirChek 52 and Leland Legacy Personal Sampling These sampling pumps are ideal for sampling airborne particulates, aerosols and toxic gases and vapors.

SENSIDYNE GILAIR 5RC

Operating Ranges: Constant High Flow Constant Low Flow Constant Pressure Approvals: SKC AIRCHEK 52 Range: Compensation Range: DAWSON 1-300 Flow Rate:

SKC LELAND LEGACY Flow Range: Compensation Range:

750 to 5000cc/min up to 38” of water 5 to 500cc/min up to 20” of water 5 to 500cc/min up to 20” of water Intrinsically safe 5 to 3000ml/min 5 to 500ml/min with constant pressure controller 1000ml/min up to 25” of water 2500ml/min up to 25” of water 300ml/min up to 15” of water 3 to 20IPM

5000 to 15,000 ml/min 15,000 ml/min at 5 inches water back pressure 10,000 ml/min at 12 inches water back pressure 5000 ml/min at 20 inches water back pressure

Page 29: Environmental Monitoring

800-242-3910

ENV 22

BIOS Defender and BIOS DryCal DC-Lite Calibrator • Dry Primary Standard Calibrator• Used for accurate calibration of all commercially

available industrial hygiene and environmental air sampling pumps

• NIST traceable calibration• Simple push-button operation

DC-Lite: DCL 12k: DCL 20k: DCL 40k: Defender: 510 Low Flow: 520 Medium Flow: 510 High Flow:

DC-Lite:

Defender:

Flow Range

10ml/min to 12 Ipm20ml/min to 20 Ipm 1 to 40 Ipm

5 to 500 ml/min50 to 5,000 ml/min 300 to 30,000 ml/min Air Flow Accuracy

±2% single reading ±1% averaged reading

±1.0% (Volumetric) ±1.2% (Standardized)

INDUSTRIAL HYGIENE

BIOS DryCal DC-Lite and BIOS Defender

Quest Temp 34 Area Heat Stress Monitor

Quest Temp 34 Area Heat Stress Monitor • Datalogging Thermal Environment Monitor• NIST traceable calibration

Temperature Accuracy Relative Humidity User Programmable Data-logging Intervals Data-logging Capacity Output Approvals

23° to 212°F (-5° to 100° C) ± 0.9°F (± 0.5°C) 0 to 100% RH / Accuracy ±5% Degrees C or F 1,2,5,10,15,30 or 60min 11 days at 1 minute intervals RS-232 port UL/CSA intrinsically safe for Class I, Groups, A, B, C, D, and Class III, Groups E, F, G, Temperature Code T3

Page 30: Environmental Monitoring

www.ashtead-technology.com

ENV23

Thermo MIE Personal DataRAM PDR 1000 AN and PDR 1500

Thermo MIE PDR 1000 AN and PDR 1500 Personal DataRAM • Direct-Read Personal Aerosol Monitor• Measures concentrations of dust, smoke, mists

and fumes in real time• Audible alarm if user defined level is exceeded (1000 model) • Integral data-logging

Concentration Measurement Range Resolution

Accuracy Particle Size Range of Max. Response

PDR 1000 AN PDR 1500

0.001 to 400mg/m³ 0.001 to 400mg/m³ range

0.1% of reading .1% of reading or 0.001mg/m³ or 0.001mg/m³ whichever is greater whichever is greater

± 5% of reading ± 5% of reading 0.1 to 10µm 0.1 to 10µm

INDUSTRIAL HYGIENE

Thermo MIE DataRAM 4 DR-4000

Thermo MIE DataRAM 4 DR-4000 • With appropriate particle discriminators, the

DataRAM provides measurements correlated with PM10, PM2.5 and respirable fractions

• Volume median particle sizes measured to 0.05µm • Continuously monitors the real-time concentration

and median particle size of airborne dust, smoke, mist, and fumes

• Patented two-wavelength particle detection system provides the volume median particle diameter of the sampled aerosol, over a concentration range of up to 400mg/m3

• Monitors the concentrations of fine particulates in ambient air by a combination of aerodynamic size preselection, two-wavelength nephelometry and concurrent sensing/correction for relative humidity

Range Accuracy Particle Size Range Maximum Response (Concentration Measurements) Sample Flow Rate Datalogging Output

0.0001 to 400mg/m³ (autoranging) +/-2% of reading 0.08 to 10µm 1.0 to 3.0 liters/minute 50,000 data points in up to 9 data groups RS-232/RS-485 port

Page 31: Environmental Monitoring

800-242-3910

ENV 24

Holaday Industries Electric and Magnetic Field Monitors • Holaday Industries Low Frequency EMF System HI

3603, HI 3604 and HI 3616• Holaday Industries ELF Magnetic Field Meter

HI 3627• Holaday Industries DC Magnetic Field Meter

HI 3550

The HI 3604 evaluates electric and magnetic fields associated with 50/6- Hertz power lines and electrically operated equipment and appliances. The HI 3603 radiation survey meter is designed for measuring the complex electromagnetic field emissions from computers, video display terminals, any CRT or similar devices. The HI 3627 gathers isotropic measurements from any ELF source such as electrical circuits, VDT’s, household wiring and appliances. The HI 3550 is a portable device used to monitor static (DC) magnetic fields from medical diagnostic instruments.

HI 3603 HI 3604 HI 3627 HI 3550

Range E-Field: 1 to 2000V/m H-Field: 1V/M to 200 kV/m E-Field: 1 to 200kV/m H-Field: 0.1m gauss to 20 gauss 2, 20, 200m gauss, 2, 20 gauss full scale 0.1 mT to 0.3T

INDUSTRIAL HYGIENE

Holiday Industries HI 3550, HI 3603 and HI 3627

Holaday Industries Broadband RF Field Strength Meter Model HI 4012

Holaday Industries Broadband RF Field Strength Meter HI 4012 • Automatic self-zeroing circuit• Accurate in any RF/microwave field environment• Designed for maximum accuracy and ease of

operation

Frequency Response E-Field H-Field Dynamic Range E-Field H-Field Accuracy at Calibration Frequencies Power Probe Length

0.5MHz to 5GHz, ± 2dB 5MHz to 300MHz ± 2dB Probe 10² to 106V²/M² Probe .001 to 10A²/M² 0.5dB 14 C-size batteries 30” with 60” cable

Page 32: Environmental Monitoring

www.ashtead-technology.com

ENV25

International Light Radiometer/Photometer Model 1400A

International Light Radiometer/Photometer Model 1400A • Ideal for use in phototherapy, health hazard,

environmental and R&D applications

UV Actinic Detector IR Hazard Detector Illuminance Detector UVA Hazard Detector Dynamic Range Linearity

SEL 240/T2 ACTS- Spectrally matches the new extended UV hazard band established by ACGIH and recommended by NIOSH from 190 to 400nm, For TLV UV hazard exposure and atmospheric ozone depletion measurements SEL 623/SCS 695/W- For ACGIH IR Hazard measurements, Spectra range is 675 to 3200nm SCL 110-Measures the extremes of photometric illuminance from starlight to sunlight, Dynamic range of 200mlux to 700klux, Direct readout in foot-candles SEL 033/UVA/W- Provides fast and accurate irradiance measurements of any UVA type source (including phototherapy, NDT and entertainment- blacklight), Spectral range of 315 to 390nm 10pA to 350mA ±0.2%, ±1 digit on the low end

Holaday Industries Microwave Survey Meter Model 1600

Holaday Industries Microwave Survey Meter Model 1600 • Measures microwave leakage from ovens operating

at 2450MHz and 915MHz• Three survey ranges• Easy-to-read front panel analog

Ranges Accuracy Response Time Maximum Power Density

0 to 10mW/cm² at 2450 MHz 0 to 10 and 0 to 20mW/cm² at 915 MHz ± 1 dB 1 second fast, 2.5 seconds slow, to 90% of final value for a step input 2.0W/cm²

INDUSTRIAL HYGIENE

Page 33: Environmental Monitoring

800-242-3910

ENV 26

Alpha, Beta, Gamma, X-Ray Radiation Survey • S.E. International Radiation Monitor Model 4EC• Ludlum M-3 Survey meter with 44-2 Probe• Ludlum 2241 Digital Survey Meter with 44-9 Pancake Probe• Victoreen 190 Survey and Count Rate Meter with 489-110D Probe• Victoreen ASM 990 Kit Our variety of detectors from S.E. International, Ludlum and Victoreen are ideal for measuring radiation levels in many health and medical applications such as nuclear and radiation therapy, diagnostic x-rays and research labs. Other uses outside of the medical field include observation of mines, power plants, geological surveys, HazMat and scrap metal yards.

S.E. INTERNATIONAL 4EC LUDLUM M-3 WITH 44-2 PROBE LUDLUM 2241 WITH 44-9 PROBE VICTOREEN 190WITH 489-110D PROBE VICTOREEN ASM 990 KIT

Radiation Detected Range Sensitivity Alpha, beta, gamma, X-ray 0 to 0.5, 0 to 5, 0 to 50mR/hr Detects alpha to 2.5MeV, >80% efficiency 0 to 500, 0 to 5,000, 0 to 50,000CPM Detects beta at 50keV with 35% efficiency 0 to 5, 0 to 50 0 to 500µ Sv/hr Detects beta at 150keV with 75% efficiency Detects gamma and X-rays to 10keV through the end window, 40keV minimum through the case Gamma 60keV to 1.25MeV Typically 175cpm/µR/hr (137Cs gamma) Alpha, beta, gamma Typically 3300cpm, mR/hr (137Cs gamma) Alpha, beta, gamma, X-ray 1µR/h to 1R/h or 1CPM to 1,000,000CPM

Alpha, beta, gamma, neutron, X-ray 1µR/h to 1R/h or 1CPM to 5,000,000CPM

INDUSTRIAL HYGIENE

S.E. International Radiation Monitor Model 4EC

Ludlum M-3 Survey Meter with 44-2 Probe

Victoreen ASM 990 Kit

Victoreen 190 Survey and Count Rate Meter with 489-110D Probe

Ludlum 2241 Digital Survey Meter with 44-9 Pancake Probe

Page 34: Environmental Monitoring

www.ashtead-technology.com

ENV27 POSITIVE MATERIAL IDENTIFICATION (PMI)

• RMD XRF LPA-1 Lead Paint Analyzer Quickly quantify lead content on painted substrates including wood and metal from 0.25 to 0.375” thick. The unit’s “Quick Mode” setting automatically adjusts the measurement time to the least time needed to make a definitive measurement.

• Thermo Scientific Niton XLp Series 700 Multi-Element This high-resolution silicon PIN diode detector system will identify many metallic components, including steel, brass, copper and titanium alloys. Ergonomic design includes touch screen data entry RS-232 port for PC integration.

• Thermo Scientific Niton XLT 898D The 898 XLT features patented high-speed electronics for unequaled performance. It is capable of analyzing multiple elements via X-ray fluorescence spectroscopy.

• Thermo Scientific Niton XL3T GOLDD+ The XL3t handheld x-ray fluorescence (XRF) analyzer combines purpose-built, proprietary electronics with an ergonomic design and easy-to-use software, transforming XRF analysis. Includes a consumer product testing mode.

This XRF analyzer utilizes a rugged x-ray tube instead of radioactive isotopes, drastically reducing radiation licensing issues and may be carried and shipped without hazardous materials restrictions. Regulatory requirements for PMI instruments vary widely from state to state and certification or licensing may be required prior to rental, contact us for details. This item is available in the U.S. only.

Customers must possess a user license with Canadian Nuclear Safety Commission prior to shipment of the Niton Xlp radioactive source-based analyzers. License applications may be attained from the CNSC. This item is available in Canada only.

Standard grade libraries available in the Appendix for Innov-X: pg. v-vi, Niton: pg. vii-x.

Our RMD, Thermo Niton and Innov-XRF analyzers are capable of undertaking a variety of both industrial and environmental monitoring applications. Whether your job requires the analysis of alloy chemistry, grade ID, metal concentration in soil or screening of electronics and consumer goods we have an analyzer to fit your needs.

Positive Material Identification

Thermo XLp Series 700

Thermo XLT 898D

RMD LPA-1

Thermo XL3T GOLDD+

Page 35: Environmental Monitoring

800-242-3910

ENV 28

Sound Level Meters • Casella CEL-254 Type 2 with Model 282 Calibrator• Casella CEL-480 Type 1 and 2 with 1/3 Octave Band• Casella CEL-490 Type 1 with 1/3 octave band• Quest Impulse 1800 Type 1 and 2800 Type 2• Quest 2100, 2700, 2800, 2900• Quest Sound Pro Type 1 and Type 2 with 1/3 Octave Band• Larson Davis 820 Type 1 These sound level meters are ideal for use in environmental and community research, noise control analysis, industrial site noise levels and traffic and transportation studies.

Casella CEL-254 Casella CEL-480

Casella CEL-490

Quest 1800 Quest 2100

Quest 2800

Quest 2900

Quest Sound Pro Type 1 and Type 2

Range Frequency Weighting 30 to 135 dB(A) A, C

10 to 140dB in seven A, C, Z 60 dB ranges Single 140 dB A, C, Zdynamic range

35 to 140 dBA A, B, C, Linear 30 to 140 dBA, A,C 40 to 140 dBC

35 to 140 dBA A, B, C, Linear

20 to 140 dB in seven A, C, Linear60 dB ranges

0 to 140 dB in eight A, C, Z, F (Flat)80 dB ranges

SOUND, NOISE & VIBRATION MONITORING

Quest 2900, Quest 2100 and Casella CEL-480

Quest OB-100 and OB-300 Octave Band Filter Sets

Quest OB-100 and OB-300 Octave Band Filter Sets • Use with 1800/2800 or 1900/2900 sound level

meters to expand capabilities to octave band analysis

• Auto and manual modes

Frequency Selection Power Source Standards Ranges

Full manual control or automatic sequential stepping through each frequency band Sound level meter ANSI S1.11 order 3 and IEC R225 OB-100 10 ranges with center frequencies from 31.5 Hz to 16 kHz in full octave bands OB-300 33 ranges from 12.5 Hz to 20 kHz in one-third octave bands, plus 11 full-band ranges from 16 Hz to 16 kHz

Page 36: Environmental Monitoring

www.ashtead-technology.com

ENV29

Instantel Minimate Plus

Instantel Minimate Plus • A perfect vibration monitor for construction/

demolition activity, blast-monitoring for compliance, pile driving, bridge and heavy transportation monitoring or structural monitoring and analysis

• Captures full waveform records while recording in histogram mode

• 8 user-programmable channels available for advanced monitoring applications

Sample Rates Datalogging

1,024 S/s to 16,384 S/s per channel, selectable up to 65,536 S/s for 8 channels 300 events

Quest Noise Pro DLX, Casella CEL-360 and Casella CEL-350 dBadge

Noise Dosimeters • Casella CEL-360 and CEL-460• Quest Noise Pro DLX Type 1 and Type 2• Quest Q300 • Casella CEL-350 IS dBadge The Casella and Quest noise dosimeters are an excellent choice for occupational hygienists to measure worker noise exposure. These dosimeters feature datalogging capabilities, a variety of available measurements and can be configured to meet specific regulatory standards such as OSHA or ISO. The Quest Noise Pro DLX and Casella CEL-350 IS dBadge are intrinsically safe.

CASELLA CEL-360 AND CEL-460 QUEST NOISE PRO DLX

QUEST Q300

CASELLA CEL-350 IS dBADGE

Range 35 to 140dBA 40 to 110dB RMS 70 to 140dB RMS 115 to 143dB Peak

40 to 110 dB RMS 70 to 140 Peak

65.0 to 140.3dB RMS 95.0 to 143.3dB Peak

SOUND, NOISE & VIBRATION MONITORING

Page 37: Environmental Monitoring

800-242-3910

ENV 30

Quest Vibration Meter Model VI 100 • Basic wideband vibration meter designed for use

in industrial or environmental applications such as shock or pulsation checks, basic machinery condition monitoring, quality specification checks or general engineering work

• Direct readings of acceleration, velocity, displacement

Acceleration Velocity Displacement Frequency Battery Life

0.01 to 19.99, 0.1 to 199.9 g’s 0.01 to 19.99, 0.1 to 199.0cm/sec 0.01 to 19.99, 0.1to 199.9 meters x 10 -5 5 to 10,000Hz 40 hours operation

SOUND, NOISE & VIBRATION MONITORING

Quest Vibration Meter Model VI 100

Quest Havpro Vibration Monitor

Quest Havpro Vibration Monitor • Excellent screening tool for quickly and simply

determining the presence and magnitude of hazardous hand-arm and whole-body vibration levels

• Up to three simultaneous measurement channels• Comprehensive summary and time history data• Conforms to the requirements of the human

vibration standards

Dynamic Range Frequency Range Interface Standards

60dB 0.5 to 3000Hz ± 5%, 0.3 to 5000Hz ± 10% RS-232 serial interface on 8-pin DIN, up to 115kbps CE compliant, ISO 8041: 1990 and 1:1999, 2631, 5349, ANSI S3.34, ANSI 3.18

Call 800-242-3910 to request a rate schedule for any equipment seen in this catalog!Want to

know more?

Page 38: Environmental Monitoring

www.ashtead-technology.com

ENV31

Interscan Toxic Gas Analyzers 4000 Series Portables

Interscan Toxic Gas Analyzers 4000 Series Portables • Highly acute sample-draw sensor• Features include: no cell rupture or acid damage,

the elimination of undesirable sensor noise (particularly when high amplifier gain is required for low concentration measurements) and no reference electrode contamination

Accuracy Minimum Detectable Concentration Linearity Analog Output Approvals

±2% of reading 1.0% of full scale ± 1% of full scale 0 to 100mV full scale UL Classified Intrinsically Safe for use in hazardous locations, Class I, Groups A, B, C, D

4000 Series Analyzers are available for detecting:

Nitrogen Dioxide Formaldehyde Ethylene Oxide

Chlorine Dioxide Chlorine Hydrogen Chloride

TOXIC GAS MONITORING

Industrial Scientific T82, MSA Pulsar +H2S and National Draeger PAC III

Single Gas Monitors • Industrial Scientific T82• National Drager PAC III • MSA Pulsar + H2S Our selection of single gas monitors are perfect for use in confined space monitoring and a variety of industrial applications, even in the harshest conditions such as underground mines and oil rigs. The Industrial Scientific T82 and National Drager PAC III are intrinsically safe instruments

INDUSTRIAL SCIENTIFIC T82 Carbon Monoxide Hydrogen Sulfide NATIONAL DRAGER PAC III Carbon Monoxide Hydrogen Sulfide Ammonia Sulfur Dioxide Hydrogen Cyanide Chlorine MSA PULSAR + H2S Oxygen Carbon Monoxide Hydrogen Sulfide

Range Resolution 0 to 1500ppm 1pmm 0 to 500ppm 1ppm 0 to 200ppm 1ppm 0 to 100ppm 1ppm 0 to 300ppm 1ppm 0 to 50ppm 0.01ppm 0 to 50ppm 0.1 ppm 0 to 20ppm 0.01 ppm 0 to 25% 0.1% 0 to 500ppm 1ppm 0 to 200ppm 1ppm

Page 39: Environmental Monitoring

800-242-3910

ENV 32

Mercury Vapor Analyzers • Jerome J405• Jerome 431-X and 431-XC• Ohio Lumex RA-915 Light • Ohio Lumex RA-915+ The mercury vapor analyzers form Jerome and Ohio Lumex are ideal for use in a wide variety of mercury-related applications such as mercury surveys and spill response, industrial hygiene monitoring, hazardous waste site and landfill monitoring, indoor/outdoor air quality testing, mercury exclusion tests and exhaust duct monitoring.

JEROME J405 JEROME 431-X AND 431-XC OHIO LUMEX RA-915+ OHIO LUMEX RA-915 LIGHT

Range 0.5 to 999 µg/m3 .003 to 0.999 mg/m3 0.00001 to 0.1mg/m³

0.1 to 100 μg/m3

TOXIC GAS MONITORING

Jerome 431 and Ohio Lumex RA-915 Light

Jerome Hydrogen Sulfide Analyzer J605

Jerome Hydrogen Sulfide Analyzers • 631-X, 631-XC, and J605• Appropriate for odor nuisance monitoring, scrubber

efficiency testing, leak detection, regulatory compliance, corrosion control and as an accuracy check for other hydrogen sulfide monitors.

• Offers a survey mode to pinpoint an H2S source detection

• J605 offers datalogging

Range: 631-X/631-XC J605 Accuracy: 631-X/631-XC

J605 Flow Rate 631-X/631-XC J605

0.003ppm to 50ppm 0.003ppm to 10ppm

± 0.003ppm at 0.050ppm, ± 0.03ppm at 0.50ppm, ± 0.3ppm at 5.0ppm, ± 2ppm at 25ppm ±1ppb at 5ppb±3ppb at 50ppb±0.03ppm at 0.5ppm±0.3ppm at 5ppm

150 cc/min 150ml/min or 0.15l/min

Resolution: 631-X/631-XC J605

0.001ppm0.02ppb

Page 40: Environmental Monitoring

www.ashtead-technology.com

ENV33

Honeywell TLD

Toxic Gas Monitors • Honeywell TLD• PPM Technology Formaldemeter htV-m• Scott GMD NextStep

These toxic gas monitors from Honeywell and Scott are ideal for temporary facility monitoring, R&D projects, spill remediation and emergency response. By utilizing chemically sensitive casettes, these instruments are able to detect a wide variety of gases in concentrations of ppm or ppb.

HONEYWELL CHEM KEY TLD FORMALDEMETER HTV-M

SCOTT GMD NEXTSTEP

Detectable Gases Ammonia, fluorine, hydrogen chloride, hydrogen fluoride, hydrogen selenide, nitric acid, sulfuric acid Airborne formaldehyde

Isocyanide (HDI, HMDI, IPDI, MDI)

TOXIC GAS MONITORING

Thermo Scientific Miran SapphlRe Ambient Air Analyzer

Thermo Scientific SapphlRe Ambient Air Analyzer • Model XL & SL Portable Gas Detection Systems

(formerly Foxboro 100E & SE30 Models)• Infrared spectrophotometer system• Applications include ventilation studies, leak

detection, IAQ assessments, unknown gas detection, monitoring medical air and anesthetic gases, process maintenance, and workplace monitoring for toxic vapors

• On-board datalogging• The operator selects a compound from a library of

100 factory installed gases • Automatically references the appropriate

calibration information the configures itself to measure the target compound and delivers concentration readings in about 10 seconds

• SapphIRe Library located on Appendix pg. ii-iv

Measurement Range Display Pump Flow Rate Response Time Output

Any compound in infrared wavelength region from 7.7 to 14.1 microns ppm, ppb or percent, user selectable 22 1/min 10 sec 0 to 1V, parallel printer, RS-232

Page 41: Environmental Monitoring

800-242-3910

ENV 34TOXIC GAS MONITORING

Diversified Research Alpha II Radon Detector • Real-time measurement of radon concentration for

1 hour to 7 years• Displays average concentration on built in LCD

display or printed through the stand alone printer or your PC printer

• Designed for environmental surveyors, building contractors, real estate professionals and researchers

• The stability of the solid state detector design does not require frequent re-calibration

• Background noise (due to electrical interference) is filtered out by the unique design of the instrument and software

• Exceeds EPA Accuracy requirements

Measurement Sensitivity Maximum Total Error Lower Limit of Detection Measurement Interval Continuous Measurement Range

Radon concentration in pico Curies per liter of air (pCi/I) Bq/m3 4.5 ± 1 alpha counts/hour (pCi/I) Less than ±3% <0.1 pCi/I 1 to 999 hours 1 hour to 2664 days

Diversified Research Alpha II Radon Detector

Radiodetection MGD-2002 Multi-Gas Leak Detector

Radiodetection MGD-2002 Helium Leak Locator • Excellent for use during soil vapor sampling

using helium as a tracer• Wide dynamic range

Humidity Range Sensitivity Tracer Gases Resolution Battery Life

10% rH to 50% rH Min = 25ppm Max = 1,000,000ppm (100%) Helium (He), Hydrogen (H) Low range = +/ -25ppm High range = +/ -0.2% 6 to 9hrs

Page 42: Environmental Monitoring
Page 43: Environmental Monitoring

800-242-3910

ENV 36

Underground Location Systems • Mala Geoscience CX-11 Concrete Radar• Mala Geoscience Easy Locator GPR• Proceq Profometer 5 Rebar Locator• JRC Concrete Radar The Mala Geoxcience CX-11 combines radar and Electro-Magnetic (EM) technology to locate and identify energized power cables, rebar and post-tension cables. Rapidly scan areas for 2D locating and to mark targets or collect data on a grid mat supplied with the system for “in the box” 3D imaging.The Mala Geoxcience Easy Locator is easy to operate and highly effective at locating sub-surface material types. In addition to metallic objects, plastics, concrete, ceramics, asphalt composites plus many more can all be located. Featuring a rechargeable, long life Lithium-Ion battery, the Easy Locator is capable of operating up to 16 hours and can scan at various depths. We also offer two optional antenna sizes. The Proceq Profometer 5 utilizes the eddy current measuring method with pulse induction to ensure a high measuring stability. The Profometer 5 is ideal for locating reinforcing bars and welded wire meshes in up to 10” of cover.The JRC Concrete Radar is a portable light weight ground penetrating radar. Can sense the depth of up to 30cm. Ideal for quality assurance inspection of concrete. The JRC radar system enables you to locate and identify energized power cables, rebar, post-tension cables and many other metallic and non-metallic objects.

UNDERGROUND LOCATION

Mala Geoscience CX-11 and Proceq Profometer 5

Schonstedt Pipe and Cable Locator Model MAC51BX

Schonstedt Pipe and Cable Locator Model MAC51BX • Two active frequencies for pipe, cable and

line tracking and a magnetic mode for finding underground ferrous pipes, water meters and valves, property and survey markers or anything with a magnetic field.

• Passive operation for finding iron and steel targets, energized power lines

Audio Output RF Output Mode

Receiver Transmitter 40 Hz idling tone from 2.58 kHz pulsed speaker, pulsing tone at 4.4Hz increases or decreases with signal intensity 82.5kHz modulated at 382Hz, pulsed at 404Hz Lo and High Mode The receiver’s audio signal provides a sharp null when its tip is directly over the target Mag Mode does not use the transmitter, the audio signal peaks when the receiver’s tip is over the target.

Page 44: Environmental Monitoring

www.ashtead-technology.com

ENV37

Masterflex 0757100, Geotech Series II, Solinst Peristaltic Pump 410 and ProActiveTM Stainless Steel Mega Monsoon

Sampling Pumps• Masterflex 0757100 Environmental Sampling Pump• Geotech Series II Peristaltic Pump• Gundfos Redi-Flo2 Submersible Pump• ProActiveTM Stainless Steel Mega Monsoon • Waterra Hydrolift II Pump • Solinst Peristaltic Pump 410 The Masterflex 0757100 is a battery operated, portable sampling drive. This unit features easy to control pump speed, a quick load pump head and has a flow rate of 10 to 1000ml/min, depending on tubing. The Geotech Series II is for single and multi-stage vacuum pumping. The Series II is able to operate at a depth of 27’ at sea level, it is ideal for sample removal from shallow wells or any surface water source. The Grundfos Redi-Flo2 is ideal for a variety of environmental applications including groundwater sampling and conducting aquifer tests to a depth of 250’. Adjustable flow rate from 100ml/min to 9gal/min allows for uninterrupted sampling and pumping.The ProActiveTM Stainless Steel Mega Monsoon is appropriate for low flow sampling or ground water purging of monitoring wells. Its small probe design fits easily into 2” spaces or larger. The Solinst 410 is designed for field use, and is ideal for vapor sampling or water sampling from shallow wells and surface water. The Waterra Hydrolift II is a portable, electrically operated device that is used to automate the operation of the Inertial Pump.

WATER MONITORING INSTRUMENTS

QED Sample Pro Consultant Kit

QED MicroPurge® Systems • Sample Pro bladder pump (available in 1.75” and .75” )• 12 V DC compressor• MP10 and MP10 H Controller• MP15 MicroPurge® BackpackMP• MP20 D and MP 20 DT Flow Cell• MP30 Drawdown/Water Level Meter• MP40 Direct Drive Air Compressor• MP 50 Controller/Compressor

Sample Pro 1.75” Flow Rates Maximum Lift Pump Volume Sample Pro 0.75” Maximum Lift Pump Volume Maximum Pump Depth: MP10 Controller MP10H Controller

(.25” x .25” OD Tubing) 1.2IMP at 25’, 400ml/min at 150’ max 250’ 100ml 200’ 10ml 250’ 600’

Page 45: Environmental Monitoring

800-242-3910

ENV 38

QED MicroPurge® Systems • Sample Pro bladder pump (available in 1.75” and .75” )• 12 V DC compressor• MP10 and MP10 H Controller• MP15 MicroPurge® BackpackMP• MP20 D and MP 20 DT Flow Cell• MP30 Drawdown/Water Level Meter• MP40 Direct Drive Air Compressor• MP 50 Controller/Compressor

Sample Pro 1.75” Flow Rates Maximum Lift Pump Volume Sample Pro 0.75” Maximum Lift Pump Volume Maximum Pump Depth: MP10 Controller MP10H Controller

(.25” x .25” OD Tubing) 1.2IMP at 25’, 400ml/min at 150’ max 250’ 100ml 200’ 10ml 250’ 600’

Flow Cell Water Quality Systems • YSI Multiprobe 556 (4m, 10m, 20m)• YSI 600QS and 600XL (25m,50m)• YSI 6920• QED MP20D and MP20DT (1.83 m) Our flow cell water quality systems from YSI and QED are ideal for measuring the water quality in lakes and rivers, around industrial waste water plants or factories and in other environmental applications. The integrated flow cell technology provides thorough mixing of samples so no “dead spots” will interfere with parameter measurements.These systems measure a variety of parameters, including:

QED MP20D AND MP20DT

YSI Multiprobe 556 YSI 600QS and 600XL

YSI 6920

pH, dissolved oxygen, conductivity, ORP, temperature, salinity, turbidity

pH, dissolved oxygen, conductivity, salinity, ORP, temperature pH, dissolved oxygen, conductivity, salinity, ORP, air saturation, temperature

pH, dissolved oxygen, conductivity, salinity, ORP, temperature, depth, turbidity, ammonium, nitrogen, chloride, rhodamine

WATER MONITORING INSTRUMENTS

QED MP20D Water Quality Flow Cell

Horiba U-22 and YSI Multiprobe 556

Water Quality Systems • Horiba U-53G / U-53 (2m, 10m)• Horiba U-22 (2m, 10m 30m)• Horiba U-10 (2m, 10m) These water quality systems are perfect for use in applications such as factory effluent and urban drainage testing, lake and river monitoring and aquatic culture tank or agricultural water supply testing. Monitor sea, fresh, brackish, polluted or ground water with ease. These systems measure a variety of parameters, including:

Horiba U-22 Horiba U-10 HORIBA U-53/53G

pH, dissolved oxygen, conductivity, salinity, TDS, seawater specific gravity, turbidity, ORP pH, dissolved oxygen, conductivity, salinity, turbidity, temperature pH, dissolved oxygen, conductivity, ORP, temperature, salinity, specific gravity of seawater, TDS, turbidity, water depth

Page 46: Environmental Monitoring

www.ashtead-technology.com

ENV39

Myron 6P Water Quality Meter with Six Parameters

Myron 6P Six Parameter Water Quality Meter • Easy sampling: fill built-in cup with sample and

select parameter key• Memory stores and recalls up to 20 readings• Appropriate for environmental groundwater

testing, use in boilers and cooling towers, reverse osmosis, plating and parts washing, fountain solutions for printing, irrigation water, hydroponics, process verification, de-ionization and more

• Waterproof to 3’

pH ORP Conductivity TDS Resistivity Protection Rating

Range Resolution Accuracy 0 to 14pH 0.01pH ±0.01pH ±999mV ±1mV ±1mV 0 to 9,999mS, 0.01 < 100µS ±1% 10 to 200mS 0.1 < 1000µS in 5 autoranges 1.0 > 1000µS 0 to 9999ppm, 0.01 < 100ppm ±1% 10 to 200ppt 0.1 < 1000ppm in 5 autoranges 1.0 > 1000ppm 10KΩ to 30MΩ 0.01 < 100KΩ ±1% 0.1 < 1,000KΩ 0.01 > 1MΩ IP67/NEMA 6

WATER MONITORING INSTRUMENTS

Teledyne ISCO 6712 Full-Size Portable Sampler

Teledyne ISCO 6712 Full-Size Portable Sampler • Suitable for applications in wastewater effluent,

stormwater monitoring, CSO monitoring, permit compliance and pretreatment compliance

• Advanced 6712 Controller allows selection of different program modules

• Features vacuum formed ABS plastic shell to withstand harsh exposure

• 4MB for datalogging • Choice of 11 different glass and plastic bottle

configurations ranging from 24 x 1liter to 1 x 5.5 gallon (consumables available upon request)

• Pump revolution counter and patented liquid detection sensor ensure accurate sample volumes and tells you when tubing should be replaced

Maximum Lift Sample Frequency Sampling Modes

28’ (8.5m) 1min to 99hrs 59mins, in 1min increments, Non-uniform times in minutes or clock times 1 to 9,999 flow pulses

Uniform time, non-uniform time, flow, event (flow mode is controlled by external flow meter pulses)

Page 47: Environmental Monitoring

800-242-3910

ENV 40

Water Level Dataloggers • Solinst 3001 Levelogger Gold• In-Situ Troll 700 and 9500 with optical DO• In-Situ miniTroll Water Level Meter The Solinst Levelogger Gold is a self contained, high-accuracy water level and temperature datalogger. It features 0.05% FS accuracy, 10-year battery and memory for 40,000 sets of readings. This instrument is user-friendly, with intuitive software, direct read or wireline deployment and upgradeable firmware. Maintenance-free design makes this instrument ideal for long-term water level monitoring. Please ask about the Leveloader Gold, a rugged data transfer device designed for use with Solinst Leveloggers. The In-Situ Troll 700 is appropriate for precision river gauging, tidal influence studies or geothermal research. This instrument takes quick samples (0.25 seconds) and up to 4MB of datalogging.The In-Situ miniTroll monitors rivers, lakes and wells in long or short term projects. It features small diameter (0.72”) and datalogging. The In-Situ 9500 offers quick-Calibrations, automated Low-Flow sampling, field-replaceable sensors, long lasting internal power, and more, while Our field proven Optical D.O. sensor (RDO) reduces maintenance and the need to visit the site.

WATER MONITORING INSTRUMENTS

Solinst Levelogger Gold and Barologger and In-Situ Troll 700

Geotech ORS, Heron and Solinst Oil/Water Interface Meters

Interface and Water Level Meters • Heron Oil/Water Interface Meter (100’, 200’, 300’)• Heron Water Level Meter (100’, 200’, 300’, 500’)• Solinst Oil/Water Interface Meter (100’, 200’)• Solinst Water Level Meter• Geotech ORS Oil/Water Interface Probe (100’)• Geotech ORS Water Level Meter (100’, 200’) The oil and water interface meters by Heron, Solinst and Geotech are appropriate for monitoring and remediating oil-contaminated groundwater, wells and tanks. These instruments are intrinsically safe, portable and feature rugged narrow probes (5/8”) to fit into many narrow-gauge spaces. Water level meters are also available.

The Heron Oil/Water Interface Meter is used to measure the thickness of floating or sinking hydrocarbon products in groundwater accurately, reliably, safely and economically.The Solinst Oil/Water Interface Meter gives clear and accurate measurements of product level and thickness in wells and tanks. It has a sensor accuracy to 1/200 ft.The Geotech ORS Oil/Water Interface Probe rapidly and accurately measures depth to hydrocarbons and water in monitoring wells and tanks. It is lightweight, battery operated and exceptionally rugged.

(100’, 200’, 60m, 80m, 100m)

Page 48: Environmental Monitoring

www.ashtead-technology.com

ENV41

Hanna Instruments pH/Temperature/ Conductivity Meter HI 9828

Hanna Instruments pH/Temperature/Conductivity Meter HI 9828 • Capable of measuring up to 13 critical water quality

parameters (6 measured and 7 calculated) • Includes auto recognition of pH/ORP probe, auto-

ranging adjustments for EC/TDS readings, and measurement check - to eliminate erroneous readings - and more, our design actually simplifies operations and handling

• Designed for demanding outdoor environments. The meter is impact resistant and waterproof to IP67 standards (30 minutes immersion under 1 m of water), and the multi-sensor probe, HI 769828, with an IP68 rating, can be left underwater for an extended period of time.

Range Resolution

Accuracy Temperature Compensation

pH Temperature Conductivity 0.00 to 23 to 131.00°F 0 to 200 mS/cm 14.00pH (-5° to 55°C) 0.01pH 0.01° F (0.01°C)

±0.02 pH ±0.27°F (±0.15°C) ±1% of reading Automatic from 23 to 131°F (-5 to 55°C)

WATER MONITORING INSTRUMENTS

YSI Model 550A Handheld Dissolved Oxygen Instrument

Handheld Dissolved Oxygen Instruments • YSI 550A, YSI 63 and YSI 85

Accuracy

YSI 550A

YSI 63

YSI 85

Temperature Specifications

YSI 550A

YSI 63

YSI 85

0 to 20mg/L; ±0.3mg/L or ±2% of reading, whichever is greater 20 to 50mg/L; ±6% of reading 0 to 200%; ±2% air saturation or ±2% of reading, whichever is greater 200 to 500%; ±6% of reading

±0.1 unit within 10°C of calibration±0.2 unit within 20°C

±2% saturation±0.3 mg/L

Accuracy Range Resolution

±3° C -5° to 45° C 0.1°C

±1°C -5 to +75°C 0.1°C

±1° C -5 to +65°C 0.1°C -5 to 45°C for oxygen

1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm

Page 49: Environmental Monitoring

800-242-3910

ENV 42

Turbidity Meters • Hach 2100-P • LaMotte 2020 The Hach 2100-P combines microprocessor-controlled operation and Hach’s patented Ratio™ optics to bring greater accuracy, sensitivity and reliability to field testing. The LaMotte 2020 is a small turbidity meter with lab accuracy measurements for regulatory monitoring, process water testing and environmental water analysis. An EPA compliance mode rounds readings to EPA reporting requirements.

HACH 2100-P

Range Accuracy Resolution LAMOTTE 2020

Range Accuracy Resolution

0 to 1000 NTU ±2% of reading plus stray light 0.01% on lowest range

0 to 1100 NTU 0.01 (0 to 11) 0.1 (11 to 110) 1 at (110 to 1100) ±2% of reading below 100 NTU ±3% above 100 NTU

WATER MONITORING INSTRUMENTS

LaMotte 2020

Turner Designs Aquafluor™ Handheld Fluorometer/ Turbidimeter

Turner Designs Aquafluor™ Handheld Fluorometer/ Turbidimeter • Dedicated dual channels: The press of one button

easily toggles between the two applications• Floating capability and watertight design: No need

to worry when measuring samples in the field

Minimum Detection Limit: Dynamic Range Detector Internal Datalogging

• Ammonium: 0.10µM • Extracted chlorophyll a: 0.50µgL • in vivo chlorophyll a: 0.30 µg/L• • Cyanobacteria: 150 cells/mL• • Rhodamine WT: 0.4ppb • Fluoresein: 0.4ppb • Turbidity: 0.5 NTU 3 orders of magnitude Photodiodes with measurement capability from 300 nm to 1,000 nm Up to 1,000 data points

Page 50: Environmental Monitoring

www.ashtead-technology.com

ENV43

Global Flow Probe, Peek DCT 7088 and Marsh McBirney Flo-Mate 2000

Velocity and Flow Meters • Global Flow Probe Digital Water Velocity Meter• Marsh McBirney Flo-Mate 2000 Portable Flowmeter• Peek DCT 7088 Digital Correlation Transit Time

Flowmeter The Global Flow Probe measures flow in open channels and partially filled pipes and is ideal for stormwater runoff studies. The probe can be placed directly on the bottom of the channel to measure flow to 1.5” in depth. The Marsh McBirney Flo-Mate 2000 features instantaneous readout of flow velocity which is ideal for calibrating flumes, weirs, streams, sewers or mining and irrigation canals. This instrument includes two user selectable data averaging features (fixed period averaging or time constant mode) and memory storage of up to 19 points. The Peek DCT 7088 is designed for clean liquid applications. This flowmeter tolerates high concentrations of entrained solids or gas bubbles and features bidirectional flow measurements. Its flexibility makes it appropriate for HVAC, potable water, ultrapure liquids, de-ionized water, petroleum products or water and waste management studies.

WATER QUALITY INSTRUMENTS

Call 800-242-3910 to request a rate schedule for any equipment seen in this catalog!Want to

know more?

Colorimeters • Lamotte SMART 2• Hach DR/890 The Lamotte SMART 2 is the direct reading colorimeter for complete on-site water analyses. All of the 50 pre-programmed tests can be run on this compact instrument and each test features automatic wavelength selection. The unit includes 85 pre-programmed tests along with 10 user tests. The Hach DR/890 combines ease of use, multiple testing capabilities and field rediness. They are designed specifically for the rigors of on-site testing, with rugged components and waterproof, dustproof, chemical-resistant housings. The DR/890 offers simple, push-button program selection and step-by-step prompts that guide users through the testing procedure. These instruments are equally appreciated by experienced analysts who value test efficiency and by operators who require ease of use with accurate results.

Page 51: Environmental Monitoring

800-242-3910

ENV 44

Wireless Transmitters • RAE Systems RAELink2• RAE Systems RAELink3

The RAELink2 allows real-time data transmission between the TSI 8520 DustTrak® and your computer or laptop (base station), which can be located up to two miles away. Each ProRAE Remote Base Station can communicate with and can be configured to allow data from up to 32 remote monitors.The RAELink3 modem allows integration of many RAE Systems gas and radiation monitors, and select third-party devices into an wireless detection system. Monitors linked with a RAELink3 modem can communicate sensor data and GPS coordinates to a command center’s PC running ProRAE Remote Software up to 2 miles away. Bluetooth connectivity simplifies use with handheld monitors, while a user-friendly display and interface simplify configuration and status checking of the RAELink3.

SPECIALTY INSTRUMENTS

RAE Systems RAELink3

Kestrel® 4500, Davis Vantage Pro2 and Casella Nomad

Weather Stations • Davis Vantage Pro2• Kestrel® 4500 Pocket Weather Tracker• Casella Nomad Portable Weather Station The Davis Vantage Pro2 provides forecasting, on screen graphing, radiation protected temperature and humidity sensors and datalogging.The Kestrel® 4500 is built for wind direction and speed. It also calculates crosswind and headwind/tailwind and stores the information along with all the other environmental readings in its 1400 data point memory.The Casella Nomad is an automatic weather system which outputs data directly back to an incident command vehicle, where it can run in conjunction with the Aloha and CAMEO software packages, allowing appropriate evaluation measures to be undertaken.

DAVIS VANTAGE PRO2 KESTREL® 4500

CASELLA NOMAD

Weather Information Includes: Inside/outside temperature, rainfall amount, humidity levels, wind speed, wind direction/wind chill factor, barometric pressure trend, heat index, dew point, time of sunrise and sunset, moon phase forecasting icons Wind speed, wind direction, crosswind, altitude, barometric pressure, relative humidity in %, heat stress index, dewpoint, wet bulb temperature, density altitude, wind chill, temperature, air velocityWind speed, direction, air pressure, air temperature, sunshine, relative humidity, rainfall

Page 52: Environmental Monitoring

www.ashtead-technology.com

ENV45

Engineering Solutions OMNIGUARD 4 Differential Pressure Recorder

Engineering Solutions OMNIGUARD 4 Differential Pressure Recorder • Not position sensitive: continuous measurements if

unit is moved• Includes built-in printer and software

Operating Ranges Resolution Accuracy Pressure Calibration Burst Pressure Datalogging Alarms

±/-0.250” Water Column ( -6.35mm WC, +/-62.5 Pascals) 0.001 inches Water Column (+/-0.05mm WC, +/-0.5 Pascals) +/-0.003 inches Water Column or +-1% of reading whichever is greater “WC (inches Water Column), mmWC Zero Cal function, temperature compensated 3psi 128,000 character, 30+ days of readings (over 4000 logged events) Two programmable alarm set points, 95db audible alarm with flashing LED and on-screen warning indicate alarm condition

SPECIALTY INSTRUMENTS

Landtec GEM 500 and GEM 2000

Landtec GEM Landfill Gas Monitors • GEM 2000 and GEM 2000 Plus*• GEM 500 The GEM 2000 and 2000 Plus were designed to monitor landfill gas extraction systems, flares and migration control systems by sampling and analyzing the methane, carbon dioxide and oxygen content of landfill gas (the plus model also monitors CO and H2S). These intrinsically safe instruments measure gas flow rate, BTU content, relative and atmospheric pressures and CH4 LEL. The GEM 500 is used to monitor landfill gas (LFG) migration control systems, gas extraction systems, flares, migration probes, LEL levels and subsurface lines. Measurements are gathered by a self-compensating infrared gas analyzer and an internal sample pump.

GEM 2000, 2000 PLUS* Methane Carbon Dioxide Oxygen Carbon Monoxide* Hydrogen Sulfide* GEM 500 Methane Carbon Dioxide Oxygen

Sensor Range Resolution 0 to 100% 0.1% 0 to 60% 0.1% 0 to 25% 0.1% 0 to 2000ppm 0.1% 0 to 200ppm 0.1% 0 to 70% 0.1% 0 to 50% 0.1% 0 to 25% 0.1%

Page 53: Environmental Monitoring

800-242-3910

ENV 46

AMS Basic Soil Kit • This kit gives you the ability to auger in most

materials up to 12’ and then collect a soil core sample

Tools Included in the Kit

1 Regular Auger 1 Mud Auger 1 Sand Auger 1 Rubber Coated Cross Handle 1 2” x 6” Core Sampler* 1 1/2” x 6 1 Slide Hammer 1 AMS 2” x 12” Nylon Brush 2 Crescent Wrenches 1 Universal Slip Wrench 1 AMS Deluxe Poly Reinforced Case 3 4’ Extensions *Patent Pending, USA & Foreign

TSI PortaCount Plus Fit Tester Model 8020 and N95-Companion Kit

AMS Basic Soil Kit

Generators • Honda 2000I• Multiquip 3600 Power anything with our generators from Honda and Multiquip. Please ask about other available models and power ranges.

Multiquip 3600 Generator

TSI PortaCount Plus Fit Tester Model 8020 and N95-Companion Kit • Quantitative fit tester• OSHA-accepted for all fit testing regulations• Includes software and optional printer available• N-95 Companion kit rents separately

Fit Factor Range Concentration Range Particle Size Range Fit Factor Accuracy Output Compatible With:

1 to greater than 10,000 0.01 to 5 x 105 particles/cm³ 0.02 to greater than 1µm ±10% of reading RS-232 port Almost any respirator, including elastometric half and full-face mask, PAPRs, Scba and Class-100 and Class-99 disposable (filter face-piece) respirators

SPECIALTY INSTRUMENTS