englefield nz - installation instructi ons...kohler nz ltd free ph: 0800 100 382 free fax: 0800 664...
TRANSCRIPT
![Page 1: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/1.jpg)
1265059-A2-D June 2016
INSTALLATIONINSTRUCTIONS
TOILET EVORATM
Back-to-Wall
09/08/2016 11295690-A02-B
With an Englefield toilet suiteyou can be sure of havingexcellence, comfort, durabilityand style.
It’s the details that Englefieldcares about - from pioneeringthe latest technology, to innovative design.
NOTE: The Evora Back-to-Wall toilet suite is suitable for both a rear & side entry water inlet.
TM
![Page 2: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/2.jpg)
CAUTION: Risk of personal injury or product damage. Handlewith care. Vitreous china can break or chip if the product is handled carelessly.
Observe all local plumbing and building codes. Installation shall be inaccordance with AS/NZS 3500 and AS/NZS 6400.
Carefully inspect the new toilet for damage.
If the existing toilet does not have a supply shut-off valve below thecistern, install one before installing the new toilet.
Install sufficient backing behind the finished wall to provide a securematerial for the anchoring devices.
Water supply hose not supplied. Your plumber can provide a suitablehose of sufficient length from the shut-off valve to the tank inlet.
WARNING: Ensure that no part of the cistern inlet hose is submerged in water.
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD
BEFORE YOU BEGIN
ENGLEFIELD2
Before proceeding with installation, please read these instructions carefully to familiarise yourself with the required tools, materials and installation sequences. Please leave these instructions for the consumer after installation.
Prior to installation, inspect the toilet to ensure that no damage has occurred in transit. If damage has occurred, or a visible defect exists, do not proceed with installation, and advise your supplier immediately.
![Page 3: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/3.jpg)
250mm hose forTop/Rear install
(supplied with cistern)
Side Inlet Valve(for Top Rear Entry.
Supplied with cistern)
Caulking Gun
Adjustable PliersMetal File1/2” SocketHacksawSilicone SealantPencilScrewdriver
Safety Glasses
Tape MeasureAdjustableSpanner
Level Pipe Wrench
Tube Cutter
Sponge
Drill & Bits
Side EntryCapping Plug
Pan Fixing Kit(supplied)Water Supply Hose(not supplied)
Cistern Bung(supplied with cistern)
Shut-off Valve(not supplied)
Vario Connector(supplied)
Bottom Inlet Valve(supplied with cistern)
INSTALLATION INSTRUCTIONS
ENGLEFIELD2
TOOLS AND MATERIALS REQUIRED
Back-to-Wall Toilet Suite
ENGLEFIELD3
PARTS IDENTIFICATION
EVORATM
![Page 4: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/4.jpg)
3
1 Remove the existing toilet: Turn off the water supply and flush the toilet,then sponge out all remaining water from the cistern. Disconnect the supplyhose from the shut-off valve and remove the old pan and cistern.CAUTION: Risk of hazardous gases. Temporarily stuff a rag in the closetflange. Ensure this is removed before installing the new toilet. Identify the type of toilet installation:A) Side Entry with Bottom Inlet or B) Top Rear Entry with Side Inlet Valve.For Side Entry toilets, the bottom inlet valve is supplied with the cistern.
BottomInletValve
BottomInlet
SideInletValve
2
For Side Entry/Bottom Inlet installations, check the shut-off valve position.
Left-handvalve position
Right-handvalve position
Shut-offvalve
Shut-offvalve
Side entry hole
For Top Rear Entry installations, skip to Pan Installation on page 6.For Side Entry/Bottom Inlet installations, proceed with instructions, below.
B) Top Rear Entrycistern configuration
CisternInlet Hose
Top RearEntry
Bung
Side entry hole
NOTE: For shut-off valves positioned on the right-hand side,a longer water supply hose may be required (not supplied).
WARNING: Ensure that no part of the cistern inlet hose is submerged in water.
CaptiveNut(in pan)
CaptiveNut(in pan)A) Bottom inlet
cistern configuration
ENGLEFIELD4
INSTALLATION INSTRUCTIONSBack-to-Wall Toilet Suite
PREPARING TO INSTALL
EVORATM
![Page 5: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/5.jpg)
3 Position the cistern on the panby centering the gasket on thepan inlet. Securely tighten thescrews so the cistern is level.
4 Connect the supply hose tothe cistern inlet and feed thehose through the appropriateside hole in the pan.
5 Connect the supply hose to the shut-off valve to test the systemfor leaks. Shut off the water supply and disconnect the hose. Insert a capping plug into the unused hole.
1 Remove the Side Inlet valve and 250mm hose.
2 Install the Bottom Inlet valve to the cistern. Discard the bung. Placethe washers over the fixing screws and locate in cistern fixing holes.
Capping Plug
Water Supply Hose(Not supplied)
Gasket
Screw
Pan Inlet
NOTE: Bottom Inlet Valve has been preset to deliver a full flush volume of 4.5L.
Side Entry Holes
BottomInletValve
Washer
Seal
NutCaptivated Nut(in pan)
Rubber SealWasher
Fixing Screw
CISTERN INSTALLATION - BOTTOM INLET
ENGLEFIELD4
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD5
Skip this page if installing aTop Rear Entry cistern configuration.
![Page 6: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/6.jpg)
1 Define the position of the connector: Place the connector onto the pan,and position the connector between the outlet and waste pipe. Installation instructions are supplied with each respective pan connector.
Case 1 Finished Wall
Pan
Waste Pipe Connector
Setout
2 Using the template, mark the positions of the floor fixing kit holes.
Case 2 Finished Wall
Vario Connector
Pan
Offset Pan Collar
Setout
Wall
VarioConnector
Case 3 Finished
Setout
Pan
Offset Pan Collar
PAN INSTALLATION
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD6
Template
Fixing holelocations
Wall
![Page 7: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/7.jpg)
3
4
5
6
Drill fixing holes at the marked locations on the floor and insert theanchors where required.
Place a washer onto each of the hexagon screws and fix the bracketsto the floor.
Position the toilet in the marked location, while ensuring an effectiveconnection is made with the pan connector.
Install the plastic screw sleeves and use the screws to fix thetoilet to the brackets. Attached the chromed caps to the screw heads.
Anchor
ScrewSleeve
Hole
Cap
HexagonLag Screw
Bracket
WasherAnchor
For Side Entry/Bottom inlet installations, skip to Push Button Installation on page 9.For Top Rear entry installations, proceed to Cistern Installation on page 8.
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD7
![Page 8: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/8.jpg)
4 Insert capping plugs into the side entry holes in the pan.
1 Securely install the bung into the bottom inlet of the cistern. Placethe washers over the fixing screws and locate in cistern fixing holes.
2
Skip this page if installing abottom inlet cistern configuration.
Bung
Seal
Washer
Nut
Captivated Nut(in pan)
Seal
Washer
Fixing Screw
Position the cistern on the panby centering the gasket on thepan inlet. Securely tighten thescrews so the cistern is level.
3 Connect the supply hose tothe cistern inlet and connect thehose to the water supplyshut-off valve.
Gasket
Screw
Pan Inlet
5 Connect the supply hose to the shut-off valve to test the systemfor leaks. Shut off the water supply and disconnect the hose.
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD8
CISTERN INSTALLATION - TOP REAR ENTRY
Cistern InletHose(supplied)
Side Entry Holes
![Page 9: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/9.jpg)
1 Disassemble the push rods. 2 Using the push rod, measurethe distance between the flushvalve and the top of the cisternlid. Mark this length and cut thepush rod to length.
3 Reassemble the push rods. 4 Fit the lid and test the buttons.Adjust the rods as required.
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD9
PUSH BUTTON INSTALLATION
![Page 10: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/10.jpg)
2
Flush Valve B1
2
Flush Valve A1
1
2
1
2
Release flush valve by turninganti-clockwise and pulling straightup on the canister.
Release flush valve bysqueezing the tabs on bothsides of the canister and pullingstraight up out of the flushvalve.
Assemble flush valve by pushingstraight down into the canisterand turning clockwise.
Assemble flush valve bypressing it into the flush valve soit snaps into place.
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD7 ENGLEFIELD10
FLUSH VALVE REMOVAL AND INSTALLATION
![Page 11: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/11.jpg)
1 Install the seat as per the supplied seat instructions.
2 Make final connection of water supply hose to shut-off valve. Test thesystem for leaks.
Your toilet suite is now installed.
Please refer to the Homeowner’s Guide for care & cleaning instructions.
3 Apply a suitable sealant between the pan and adjacent surfaces.
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD11
FINALISING INSTALLATION
2
3
1
![Page 12: Englefield NZ - INSTALLATION INSTRUCTI ONS...KOHLER NZ LTD Free Ph: 0800 100 382 Free Fax: 0800 664 488 (1 800 364 533) field.co.nz For warranty information, please visit our website](https://reader034.vdocuments.us/reader034/viewer/2022050523/5fa6ed147528ae7234180bc7/html5/thumbnails/12.jpg)
INSTALLATION INSTRUCTIONSEVORATM Back-to-Wall Toilet Suite
ENGLEFIELD7 ENGLEFIELD12
CONTACT AND WARRANTY INFORMATION
NEW ZEALAND KOHLER NZ LTDFree Ph: 0800 100 382Free Fax: 0800 664 488 (1 800 364 533)www.englefield.co.nz
For warranty information, please visit our website
AUSTRALIA KOHLER CO.
Free Ph: 1 800 ENGLEFIELD
www.englefield.com
09/08/20161295690-A02-B