CABINET• 20 gauge galvanized pre-painted steel corrosion resistant• Cabinet liner: Polythylene Foam Rated UL94 HF-1
ELECTRONIC COMPONENTS• Electrical Input Voltage: 120 VAC/60Hz / 1-Phase. • Electrical Input Current: 1.0 Amps Max• Circuit output voltage: 5VDC nominal• Integrated auxiliary furnace interlock relay• RoHs compliant
MOTORS• Two permanent sealed, lubricated variable speed
PSC Motors. (Maintenance free)• Maximum RPM 2695 / Horsepower; 3/32 HP.
Class F, thermally protected• CSA 22.2 #113-10, clause 8.3.5
– Backup protection – totally enclosed motor
POLYPROPYLENE HRV CORE• Dimensions 12"x 12"x 10" depth
(304.8 mm x 304.8 mm x 254 mm)• Corrugated cross-flow polypropylene layers,
rated UL94 HB & HF-1• Cross-flow that transfers sensible heat• Endure harsh temperatures; effective in cold climates• Water washable
DUOTROL™ BALANCING SYSTEM• The system is balanced by adjusting each
motor independently• No balancing dampers required• Connection terminals for optional wall controls• Quiet and energy efficient
DEFROST• Advanced 5th port damper defrost sequence• Defrost type: Recirculation Activated automatically
at -5°C (23°F)• Recirculation of warm ambient air throughout the home
DUCT CONNECTIONS• Insert Slide & Fix (ISF™), removable collars system • Five (5) 6" (152.5 mm) dia. round double collar.
MOUNTING• Adjustable mounting strap system
FILTERS• Two (2) Fiberbond washable - 1111⁄16"x 93⁄4"x 5⁄8"
(297 mm x 248 mm x 15.9 mm)• UL Class 2
WARRANTY• 10 year limited warranty on motors• 5 year limited warranty on parts• Lifetime limited warranty on Heat Recovery Core
AIRFLOW
XDH 7.15 HRV ModelHeat Recovery Ventilator with Recirculation30 CFM (14 L/s) to 150 CFM (71 L/s)Item No. 102610 (XDH 7.15 Greentek)
ENGINEERING DATA
PP1001/ JUNE2017
Imperial Air Technologies Inc. reserves the right to modify a product, without prior notice, whether in design, colour or specifications, in order to offer at all times a quality product that is highly competitive. Please consult your national and local building codes to find out whether the installation of electrical products requires the services of a certified technician or electrician. GreentekTM is a registered Trademark used under license by Imperial Sheet Metal Ltd. All rights reserved.
Imperial Air Technologies480 Ferdinand Blvd., Dieppe, NB Canada E1A 6V9
Toll free: 1 888 724-5211 Fax: 1 (506) 388-4633
Visit us at: www.greentek.ca / www.imperialgroup.ca
FEATURES• 5 operating modes
(Econo, Intermittent, Continuous, Recirculation* & High)• 100% variable speed• Integrated door pressure balancing taps• ISFTM 6" (152.5 mm) dia. collar system• Proportional defrost sequence• SPMTM Single Person Mounting system• Permanent lubrification PSC motors *Recirculation mode available with optional
Vectra EHC 1.5 Control
APPLICABLE REQUIREMENTS• HVI Certified• CSA C439 Standard - Packaged Heat/Energy Recovery
Ventilators (HRV/ERV)• CSA Standard CSA 22.2 NO.113 - Fans and ventilators• UL Standard 1812. Ducted Heat/Energy Recovery Ventilators
(HRV/ERV)• ENERGY STAR®, SRE, TRE and fan efficancy
minimum requirements
OPTIONAL ACCESSORIES• MERV 8 Inline 6" (152.5 mm) filter box• R-2 Style high performance supply & exhaust
ventilation hoods
Recirculation of warmambient air withoutunpleasant odors
Recirculatedwarm ambientair to home
Fresh airfrom outside
Exhaust airto outside
Exhaust airfrom home
Fresh airto home
Continuous Ventilation Mode
Advanced Defrost Sequence / Recirculating Mode
Recirculation of warmambient air withoutunpleasant odors
Recirculatedwarm ambientair to home
Fresh airfrom outside
Exhaust airto outside
Exhaust airfrom home
Fresh airto home
Continuous Ventilation Mode
Advanced Defrost Sequence / Recirculating Mode
DIMENSIONS DATA
MINIMUM CLEARANCE DATA
Dimension Data for DH 7.15
Minimum Clearance Data for DH 7.15
Front View
21.47"545.3 mm
6"152.5 mm
31.9"810.2 mm
2.8"72.4 mm
5"126 mm
15"381 mm
3"76.2 mm
12"305 mm
3"76.2 mm
15"381 mm
5.5"140.5 mm
11.3"287.9 mm
Top View
Front View
Minimum plugclearance
15"381 mm
Ceiling
Minimum clearance for drain fittingRecomended minimum clearancefor “P” trap of 10" (254 mm)
Wall
Wall Minimum door clearance
Top View
Dimension Data for DH 7.15
Minimum Clearance Data for DH 7.15
Front View
21.47"545.3 mm
6"152.5 mm
31.9"810.2 mm
2.8"72.4 mm
5"126 mm
15"381 mm
3"76.2 mm
12"305 mm
3"76.2 mm
15"381 mm
5.5"140.5 mm
11.3"287.9 mm
Top View
Front View
Minimum plugclearance
15"381 mm
Ceiling
Minimum clearance for drain fittingRecomended minimum clearancefor “P” trap of 10" (254 mm)
Wall
Wall Minimum door clearance
Top View
Front View
Front View
Top View
Top View
ENGINEERING DATA XDH 7.15 HRV
VENTILATION PERFORMANCE External Static Net Supply Gross Air Flow Gross Air Flow Pressure Air Flow Supply Exhaust Pa in. wg L/s CFM L/s CFM L/s CFM 25 0.1 77 163 78 165 85 180 50 0.2 70 148 71 150 80 170 75 0.3 64 136 65 138 73 155 100 0.4 57 121 58 123 67 142 125 0.5 50 106 50 106 59 125 150 0.6 44 93 44 93 51 108 175 0.7 36 76 36 76 44 93
cfm
(L/s
= n
x 0
.471
9)
External Static Pressurein wg (Pa = n x 248.36)
0
50
100
150
200
250
300ExhaustSupply
0.1 0.2 0.3 0.4 0.5 0.6 0.7
pcm
(L/s
= n
x 0
,471
9)
Pression statique externe(Pa = n x 248,36)
0
50
100
150
200
250
300ÉvacuationAlimentation
0.1 0.2 0.3 0.4 0.5 0.6 0.7
SPECIFICATIONS XDH 7.15 HRVDimensions 371⁄2" x 241⁄4" x 113⁄8" (952.5 mm x 616 mm x 287 mm)
Duct Connections Five (5) 6" (152.5 mm) dia. ISF double collar system
Airflow Rates 30 CFM (14 L/s) to 150 CFM (71 L/s)
Motor Two (2) PSC variable speed backward curved
Voltage 120 VAC @ 60 Hz / 1 Phase
Amperage 1.0 A / 100 watts
Type of heat exchanger Cross-flow Polypropylene
Exchange surface 85 ft2 (7.9 m2)
Defrost type Recirculation
Filters Two (2) Fiberbond washable
Drain Connection 1⁄2" (12.7 mm)
DuoTrol Integrated Balancing System
Actual Weight 50.5 lbs (22 Kg)
Shipping Weight 56 lbs (25 Kg)
Certification HVI, ENERGY STAR, CCSAUS, CSA 22.2 NO.113 Complies with UL 1812
OPTIONAL WALL CONTROLSDigital EHC1.0TC and EHC1.5DC
Mechanical RD-1, RD-2, RD-3P and RD-4P
Timers T3 (20, 40, 60 minutes)
WALL CONTROL DIMENSIONSEHC1.0 & EHC1.5
Mechanical
T3 Timer
Quoted by: Date:
Project: Remarks:
Quantity:
Model:
Site:
Architect:
Engineer:
Contractor:
ENERGY PERFORMANCE Supply Temperature Net Air Flow Power Consumed Sensible Recovery Efficiency Adjusted Sensible Recovery Efficiency °C °F L/s CFM Watts SRE % ASRE %
0 32 30 64 52 71 76
0 32 40 85 60 68 73
0 32 50 106 72 65 69
-25 -13 32 68 59 64 67HE
AT
ING
This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. It meets ENERGY STAR® requirements only when used in Canada.
2.75”(69.9 mm)
1.26”(32 mm)
2.64”(67 mm)
4.50”(114 mm)
0.62”(15.75 mm)
2.75 po(69.9 mm)
1.26 po(32 mm)
2.64 po(67 mm)
4.50 po(114 mm)
0.62 po(15.75 mm)
2.75”(69.9 mm)
1.26”(32 mm)
2.64”(67 mm)
4.50”(114 mm)
0.62”(15.75 mm)
2.75 po(69.9 mm)
1.26 po(32 mm)
2.64 po(67 mm)
4.50 po(114 mm)
0.62 po(15.75 mm)
6”(150mm)
1.73”(44mm)
1.46”(37mm)
4.07”(103.4mm)
6 po(150mm)
1.73 po(44mm)
1.46 po(37mm)
4.07 po(103.4mm)