energy conservation in gensets installed in comsats lahore
DESCRIPTION
This presentation is regarding 'Energy Conservation', presented to our respected teacher Prof. Dr. Moinuddin Ghauri. It is a small scale design of a heat recovery system made on gensets installed in CIIT Lahore Campus. This shows how heat lost to the environment can be saved. Although the quamtum of heat on a 50 kVA genset may not be significant, but it is a demo of bigger installations which, if installed in an industry with its own power generation system, can give huge monetary benefits.TRANSCRIPT
![Page 1: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/1.jpg)
![Page 2: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/2.jpg)
Energy Conservation in Gensets Installed in COMSATS Lahore
![Page 3: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/3.jpg)
Group Members
• Kashif Arif SP10-BEC-020• Muhammad Bin Abbas SP10-BEC-025• Muhammad Hamza SP10-BEC-027• Usman Ali SP10-BEC-034• Raheel Wasim SP10-BEC-038• Zaheer Mazhar SP10-BEC-052
![Page 4: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/4.jpg)
Intro
• Reason of Presentation– Energy Crisis– Energy Loss
![Page 5: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/5.jpg)
Presentation Overview
• Sankey diagram• System’s Specifications• Heat Losses In the System• Solutions to Heat Losses• Summary
![Page 6: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/6.jpg)
A Sankey Diagram
![Page 7: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/7.jpg)
![Page 8: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/8.jpg)
Genset Design Specifications
• Consists of a diesel engine coupled with an electric generator
• Specifications:– 6 in line cylinders– 6000 cc diesel engine– Engine Speed: 1500 rpm– Fuel consumption: 22.8 litres/hr
![Page 9: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/9.jpg)
Gas Flow Rates
• Radiator cooling air flow: 192 ft3/min• Combustion air flow: 6 ft3/min• Exhaust gas air flow: 17.6 ft3/min
![Page 10: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/10.jpg)
Exhaust gas temperature: 585 oC
![Page 11: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/11.jpg)
Heat Losses (kJ/hr)
• Heat rejected to:– Exhaust system: 249,000– Water & lube oil: 251,000– Radiation to room: 174,000
![Page 12: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/12.jpg)
![Page 13: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/13.jpg)
List of All Energy Losses
• Flue gas loss• Loss to coolant and lubricating oil• Radiation loss• Vibration loss• Sound loss
![Page 14: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/14.jpg)
Solutions to Energy Losses
Heat exchanger around the exhaust pipe
Employ an absorption refrigeration system
Install micro turbines for tapping the kinetic energy of flue gases
Buoyancy of flue gases can also be used
![Page 15: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/15.jpg)
Solutions (contd.)
Use the heat of engine body
![Page 16: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/16.jpg)
Heat Exchanger Around the Exhaust Pipe
![Page 17: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/17.jpg)
Heat Exchanger Around the Exhaust Pipe
![Page 18: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/18.jpg)
Heat Exchanger Around the Exhaust Pipe
• Double pipe heat exchanger• Can be used for making steam from water• This steam can be subsequently used for
generating electricity using steam turbine power plant on a small scale.
![Page 19: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/19.jpg)
Employ an absorption refrigeration system
• The relatively low heat content of flue gases leaving the exhaust pipe can be used for running a gas absorption refrigeration cycle.
![Page 20: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/20.jpg)
Install micro turbines for tapping the kinetic energy of flue gases
• If micro turbines are installed in the exhaust pipe, the kinetic energy of flue gases can be used for running that turbine.
• Buoyancy of flue gases.
![Page 21: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/21.jpg)
Heat of Engine Body
• Emits more heat than carried by flue gases– Employ a Stirling engine
![Page 22: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/22.jpg)
Stirling Engine
![Page 23: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/23.jpg)
Summary
• Rated power output: 100 kW (actual: 80 kW)• Heat rejected to environment (Energy
wasted): 69.2 + 69.8 + 48.3 = 187.3 kW
• Out of 287 kW, only 100 kW is used!!!– Which is only 35%– Equivalent to wasting Rs. 1,630 per hr of
operation of one genset
![Page 24: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/24.jpg)
Sankey Diagram
![Page 25: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/25.jpg)
After installing heat exchanger
![Page 26: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/26.jpg)
After employing heat exchanger and stirling engine
![Page 27: Energy conservation in gensets installed in comsats lahore](https://reader036.vdocuments.us/reader036/viewer/2022062514/558e4f2a1a28ab13318b4721/html5/thumbnails/27.jpg)
JazakAllah Khair