ENDo_0

Prepared by : Osama Ahmad Almasry ..

Level 7

Course Director : Dr . M. Altammimi

Page 2: endo-130123123958-phpapp02

Goals of Root canal instruments

• To provide biologic environment to healing

•To develop canal shape to healing

Page 3: endo-130123123958-phpapp02

Endo instruments ::

•1 Hand instruments

“mouth mirror , Endo Explorer , Endo excavator , Endo plugger , Locking pliers , plastic instrument , Spreader“

•2 Instruments for pulp space preparation

Group I Hand & finger operated instruments ( Barbed broach , Rasps , K files , Hedstrom file )

Group II Low speed instruments

Group III Engine driven instruments of similar to group one

Page 4: endo-130123123958-phpapp02

Types of files ::

• Traditional : carbon steel •Stainless steel

•Niti : nickel titanium

Page 5: endo-130123123958-phpapp02

Mouth mirror

Page 6: endo-130123123958-phpapp02

Endo Explorer

Two straight # very sharp endFor Exploration of canal orifices

Page 7: endo-130123123958-phpapp02

Endo Explorer

Page 8: endo-130123123958-phpapp02

Endo spreader ( Hand ) ( Finger )

For compaction of gutta percha during obturation -Pointed tip

-Hand or finger

Page 9: endo-130123123958-phpapp02

Endo Spreader

Page 10: endo-130123123958-phpapp02

Finger Spreaders

Finger size # 15 Finger size # 20Finger size # 25

Page 11: endo-130123123958-phpapp02

Explorer vs spreader

Explorer spreader

Page 12: endo-130123123958-phpapp02

Endo Excavator

-Much longer offset from long axis -Sharp to cut pulp tissue

Page 13: endo-130123123958-phpapp02

Locking pliers

Grooves to hold paper point And Gutta percha points

Page 14: endo-130123123958-phpapp02

College Pliers

Perry Pliers

Fine tip for work within small pulp chamber

Page 15: endo-130123123958-phpapp02

Plastic instrument

Page 16: endo-130123123958-phpapp02

Endo plugger (hand )

-Flat tip -Depth orientation grooves

-Hand or finger -Can be heated

Page 17: endo-130123123958-phpapp02

Finger pluggers can be precurved to facilitate condensation. They are generally used deeper in the canal.

Page 18: endo-130123123958-phpapp02

                                                                                                          Schilder Pluggers: Note that handles used

in the School are NOT color coordinated and vary quite a bit .

Page 19: endo-130123123958-phpapp02

Heat Transfer Instruments

•Spreader – like design •Designed for repeated heating

Page 20: endo-130123123958-phpapp02

                 

                            •Chamber roof is left in the the maxillary premolar

(L). The other image (R) demonstrates what the access looks like immediately after un-roofing the chamber. The access needs to be completed with a

tapered diamond.

Page 22: endo-130123123958-phpapp02
Page 23: endo-130123123958-phpapp02

Gates-Glidden Bur

Page 24: endo-130123123958-phpapp02

Pesso Reamers

•/

Page 25: endo-130123123958-phpapp02

Lentulo Spirals

Page 26: endo-130123123958-phpapp02

Endo File

Endodontic Filesk-file #15-40 25mm length k-file #15-40 31mm length K-file #45-80 25mm lengthK-file #10 25mm lengthK-file #10 31mm length

Hedstrom Files (H- file) #15-40

Page 27: endo-130123123958-phpapp02

Barbed broaches

Page 30: endo-130123123958-phpapp02

Paper point

Page 31: endo-130123123958-phpapp02

Sealer

Page 32: endo-130123123958-phpapp02
Page 33: endo-130123123958-phpapp02

REAMER

The angle between the long-axis and the cutting blade is small ,which is why preparation by reamer is effective only in rotating motion .

Page 34: endo-130123123958-phpapp02

REAMERA reamer is manufactured from a triangular or square steel wire

that is twisted to give the typical shape of a reamer.

Page 35: endo-130123123958-phpapp02

K-FILE K-files are manufactured from square or sometimes triangular steel wire that is twisted to give the typical shape of a K-file.

The angle The tip of the instrument is cutting which makes the K-file best suited

for the preparation of straight canals .

between the long-axis and the cutting blade is greater than in a reamer,

Page 36: endo-130123123958-phpapp02

FLEXOREAMER :Flexoreamers are manufactured from a triangular steel wire

that is twisted to give the typical shape of a reamer

The angle between the long-axis and the cutting blade is small ,

and therefore preparation by flexoreamer is effective only in rotatory motion .

Page 37: endo-130123123958-phpapp02

FLEXOFILEFlexofiles are manufactured from triangular (note!) steel wire that is

twisted to give the typical profile of a K-file.

The angle between the long-axis and the cutting

blade is bigger than in reamers ,which is why

preparation by flexofile is effective both in rotating motion and in filing motion

) up and down movement(

Page 38: endo-130123123958-phpapp02

HEDSTR0EM FILE

The angle between the long-axis and the cutting blade is close to right angle,

which is why preparation by Hedstroem files is effective only

when using a filing motion (up and down movement) .

Hedstroem files are manufactured from round steel wire by grinding .

Page 39: endo-130123123958-phpapp02

NITI NiTiflex-files are manufactured from nickel-titan wire that is ground to give the typical profile of a K-file .

The angle between the long-axis and the cutting blade

is bigger than in reamers ,and therefore preparation by NiTiflex-file is effective

both in rotating motion and in filing motion

) up and down movement .(

Page 40: endo-130123123958-phpapp02
Page 41: endo-130123123958-phpapp02
Page 42: endo-130123123958-phpapp02

Total of 6 radiographs will be taken and mounted for each case.

•Preoperative radiograph (without rubber dam).•Working length radiograph (with rubber dam).•Master apical file radiograph (with rubber dam).•Master cone radiograph (with rubber dam).•Intermediate radiograph (with rubber dam).•Final radiograph (without rubber dam).

A Diagnostic Endodontic Film requires that:The tooth is centered on the film.

At least 5mm of bone beyond the apex of the tooth is visible.The image is as anatomically correct as possible.