Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 6-8 6 ENCLOSED CIRCUIT BREAKERS Product Category MCCB Enclosed Circuit Breakers Enclosures — Type 1 Selection For inches / millimeters conversion, see Application Data section. All above enclosures are suitable for use as service entrance devices n Built to order. Allow 2–3 weeks for delivery. a Surface mounted, indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”. b Neutral not included. Order as separate item from table on next page. c Neutral included in enclosure. d Surface mounted, indoor. If outdoor model is required, use prefix “W” instead of “E”. Not available in flush (“F”) model. e Use for 110-125 ampere ED4, ED6, or HED4 circuit breakers. f Will not accept breaker with shunt trip. g Will not accept 2-pole GFP or breaker with shunt trip. h Includes 100% rated breakers. i Enclosure will accept shunt trip and other internal accessories except GFP. Figure 1 Figure 2 Figure 3 Type 1 Number Maximum Weight K.O. Dimensions Fig. Breaker of Current Catalog Lb./Ship. Dimensions (inches) 6 Plcs. 2 Plcs. No. Frame Poles Rating Number Package A B C D E F G H QP, QPH, 1 HQP 1–2 0060 E0204ML1060S acg 016 07 1 8 05 1 8 03 3 8 05 3 4 03 3 4 1 1 16 1 QP, QPH, 3 0 100 E0303ML3100S acf 00 8 17 1 8 0 7 1 8 0 4 1 4 14 1 8 0 4 1 2 1 5 16 HQP 1 BQ, BQH, 3 0 100 EB3100S cf 0 32 17 1 8 0 7 1 8 0 4 3 4 14 1 8 0 4 1 2 1 5 16 HBQ 1 NGG 2-3 125 GG0121FN/SN 12 20 8 3 4 4 16 6 1 3 16 2 ED2, ED4, ED6, 2–3 0 100 E2N1S ci 008 16 23 32 07 1 2 05 1 16 13 45 64 05 1 4 1 7 8, 1 1 8, 7 8, 1 1 8, HED4 E2N1F ci 008 17 1 2 08 1 2 05 1 16 13 45 64 05 1 4 1 1 3 8, 1 3 8, 2 ED4, ED6, HED4, 2–3 0 125 CED6N1S cei 014 21 15 32 07 19 32 05 7 64 18 1 4 05 1 4 1 1 3 4, 2 1 3 4, 2 CED6 CED6N1F cei 014 22 1 4 08 1 2 05 7 64 18 1 4 05 1 4 1 FXD6, FD6, FXD6, 1 1 8, 1 3 8, 1 1 8, 1 3 8, 2 FD6, HFD6, HFXD6, 2–3 0250 F6N1S b 033 38 13 32 11 15 32 05 1 16 33 08 1 33 64 1 3 4, 2, 1 3 4, 20, HHFD6, CFD6 F6N1F b 2 1 2, 3 2 1 2, 3 JXD2, JD6, h JXD6, HJD6, 3 HJXD6, HHJD6, 2–3 0400 J6N1 b 120 41 3 16 22 27 64 10 45 64 37 18 1 4 2 5 64 HHJXD6, SJD6, SHJD6 LD6, LXD6, h HLD6, HLXD6, 3 HHLD6, HHLXD6, 2–3 0600 LD6N1 b 101 46 22 27 64 10 45 64 42 18 1 4 2 5 64 SLD6, SHLD6, SCJD6, SCLD6, CJD6, CLD6 3 LMXD6, LMD6, 2–3 0 800 LMD1 b 202 60 22 27 64 10 55 7 8 18 1 4 2 5 64 HLMXD6, HLMD6 MD6, MXD6, SMD6, h HMD6, HMXD6, SHMD6, ND6, NXD6, 3 SND6, HND6, HNXD6, 2–3 1200 MND61 b 202 60 22 27 64 10 55 7 8 18 1 4 2 5 64 SHND6, CMD6, SCMD6, CND6, SCND6 PD6, PXD6, HPD6, h HPXD6, CPD6, RD6, SPD6, SHPD6, RXD6, 3 2000 PRD6N1 n 350 90 32 28 HRD6, HRXD6 Dimensions

Upload: phungdung

Post on 15-Mar-2018

221 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog6-8

6EN

CLOS

ED

CIRC

UIT

BREA

KERS

Siemens / Speedfax Previous folio: 5-8 Updated by TA 03/22/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Type 1 Selection

For inches / millimeters conversion, see Application Data section.All above enclosures are suitable for use as service entrance devices n Built to order. Allow 2–3 weeks for delivery.

a�Surface mounted, indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”.

b�Neutral not included. Order as separate item from table on next page.

c�Neutral included in enclosure.d�Surface mounted, indoor. If outdoor model is required,

use prefix “W” instead of “E”. Not available in flush (“F”) model.

e�Use for 110-125 ampere ED4, ED6, or HED4 circuit breakers.

f�Will not accept breaker with shunt trip.g�Will not accept 2-pole GFP or breaker with shunt trip.h�Includes 100% rated breakers.i��Enclosure will accept shunt trip and other internal

accessories except GFP.

Figure 1 Figure 2 Figure 3

Type 1

Number Maximum Weight K.O. Dimensions

Fig. Breaker of Current Catalog Lb./Ship. Dimensions (inches) 6 Plcs. 2 Plcs.

No. Frame Poles Rating Number Package A B C D E F G H

QP, QPH, 1 HQP 1–2 0060 E0204ML1060Sacg 016 071⁄8 051⁄8 033⁄8 053⁄4 033⁄4 11⁄16 — —

1 QP, QPH, 3 0100 E0303ML3100Sacf 008 171⁄8 071⁄8 041⁄4 141⁄8 041⁄2 15⁄16 — — HQP

1 BQ, BQH, 3 0100 EB3100Scf 032 171⁄8 071⁄8 043⁄4 141⁄8 041⁄2 15⁄16 — — HBQ

1 NGG 2-3 125 GG0121FN/SN 12 20 83⁄4 4 16 6 13⁄16 — —

2 ED2, ED4, ED6, 2–3 0100 E2N1Sci 008 1623⁄32 071⁄2 051⁄16 1345⁄64 051⁄4 1 7⁄8, 11⁄8, 7⁄8, 1

1⁄8, HED4 E2N1Fci 008 171⁄2 081⁄2 051⁄16 1345⁄64 051⁄4 1 13⁄8, 13⁄8,

2 ED4, ED6, HED4, 2–3 0125 CED6N1Scei 014 2115⁄32 0719⁄32 057⁄64 181⁄4 051⁄4 1 13⁄4, 2 13⁄4, 2 CED6 CED6N1Fcei 014 221⁄4 081⁄2 057⁄64 181⁄4 051⁄4 1

FXD6, FD6, FXD6, 1 1⁄8, 13⁄8, 11⁄8, 13⁄8,2 FD6, HFD6, HFXD6, 2–3 0250 F6N1Sb

033 3813⁄32 1115⁄32 051⁄16 33 08 133⁄64 13⁄4, 2, 13⁄4, 20, HHFD6, CFD6 F6N1Fb

21⁄2, 3 21⁄2, 3

JXD2, JD6, h

JXD6, HJD6, 3 HJXD6, HHJD6, 2–3 0400 J6N1b 120 413⁄16 2227⁄64 1045⁄64 37 181⁄4 25⁄64 — — HHJXD6, SJD6, SHJD6

LD6, LXD6, h

HLD6, HLXD6, 3 HHLD6, HHLXD6, 2–3 0600 LD6N1b 101 46 2227⁄64 1045⁄64 42 181⁄4 25⁄64 — — SLD6, SHLD6, SCJD6, SCLD6, CJD6, CLD6

3 LMXD6, LMD6, 2–3 0800 LMD1b 202 60 2227⁄64 10 557⁄8 181⁄4 25⁄64 — — HLMXD6, HLMD6

MD6, MXD6, SMD6, h

HMD6, HMXD6, SHMD6, ND6, NXD6, 3 SND6, HND6, HNXD6, 2–3 1200 MND61b 202 60 2227⁄64 10 557⁄8 181⁄4 25⁄64 — —

SHND6, CMD6, SCMD6, CND6, SCND6

PD6, PXD6, HPD6, h

HPXD6, CPD6, RD6, — SPD6, SHPD6, RXD6, 3 2000 PRD6N1 n 350 90 32 28 — — — — —

HRD6, HRXD6

Dimensions

Page 2: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

6-9Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

6ENCLOSED CIRCUIT BREAKERS

Siemens / Speedfax Previous folio: 5-9 Updated by TA 03/22/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Type 1 Selection

For inches / millimeters conversion, see Application Data section.a�Surface mounted, indoor. If flush mounting is required,

replace suffix “S” in catalog number with suffix “F”. Also, if outdoor model required, use prefix “W” instead of “E”.

b�Neutral not included. Order as separate item from table on next page.

c�Surface mounted, indoor. If outdoor model is required, use prefix “W” instead of “E”. Not available in flush (“F”) model.

d�Use for 110-125 ampere ED4, ED6, or HED4 circuit breakers.

e�Will not accept breaker with shunt trip.f�Also for use with Type 3R, 12, 12K & 4X enclosures

(Catalog numbers F6N3R, F6N12, F6N12K & FD6SS4).

g�Also for use with Type 3R, 12 & 4X enclosures (Catalog numbers J6N3R, J6N12, & LD6SS4).

h�Also for use with Types 3R and 12 enclosures (Catalog numbers LD6N3R & LD6N12).

i�For 600 MCM neutral cable (3) in, (3) out (#4–600 kcmil Cu/Al) use catalog number W411239

Figure 4

Number Maximum WeightFigure Breaker of Current Catalog Lb./Ship. Dimensions (inches)

Number Frame Poles Rating Number Package A B C D E F G H J K L M N P

4 QJ2, QJH2, 2–3 225 EB3225S 15 27 101⁄8 27 101⁄8 51⁄4 213⁄16 213⁄8 23⁄8 3 20 51⁄16 23⁄4 23⁄4 41⁄2 QH2-H EB3225F 27 101⁄8 281⁄8 111⁄4 51⁄4 213⁄16 213⁄8 23⁄8 3 20 51⁄16 23⁄4 23⁄4 41⁄2

NeutralsNeutral Enclosure Catalog Catalog Neutral Cable Capacity Number Number and Wire Range

(1 pc.) #4 - 2/0 Cu/Al

N225QJ EB3225(S)(F) (1 pc.) #1 - 300 kcmil Cu/Al

Gnd. Lug (1pc.) #14 - #4 & (3 pcs.) #14 - #10 Cu or (1 pc.) #12 - #4 & (3 pcs.) #12 - #10 Al

(1 pc.) #14-2/0 Cu/Al, (1 pc.) #1-300 kcmil Cu/AlN125GG GG0121SN/FN Grd. Lug (1 pc.) #12 - #4 Cu/Al (3 pcs.)#12 - #10 Cu/Al

W53045 �E2N1(S)(F) (1 pc.) #14–2 Cu/Al

CED6N1(S)(F)d Grd. Lug (1 pc.) #14–8 Cu/Al

N250 F6N1(S)(F) (1 pc.) #6–350 kcmil Cu/Al Grd. Lug (1 pc.) #14–2/0 Cu/Al

(1 pc.) #1/0–750 kcmil Cu/Al orW60992 J6N1 (2 pcs.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

W60993 LD6N1 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

W63623 LMD1 (4 pcs.) 250 kcmil–500 kcmil Cu/Ali

MND61 Grd. Lug (1 pc.) #6–300 kcmil Cu/Al

N2000 PRD6N1 (6 pcs.) #3/0–750 kcmil Cu/Al Grd. Lug (2 pcs.) #3/0–750 Cu/Al

200% Neutrals (For Type 1, 3R, 4/4X and 12 Enclosures)Neutral Enclosure Catalog Catalog Neutral Cable Capacity Number Number and Wire Range

N2250 F6N1(S)(F)f (2 pcs.) #4–350 kcmil Cu/Al Grd. Lug (1 pc.) #14–2/0 Cu/Al

W60993 J6N1g (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6-250 kcmil Cu/Al

W63623 LD6N1h (4 pcs.) 250 kcmil–500 kcmil Cu/Al Grd. Lug (1 pc.) #6–300 kcmil Cu/Al

Dimensions

Page 3: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog6-10

6EN

CLOS

ED

CIRC

UIT

BREA

KERS

Siemens / Speedfax Previous folio: 5-10 Updated by TA 03/22/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Type 3R Selection

Figure 1 Figure 2 Figure 3

For inches / millimeters conversion, see Application Data section.Note: All above enclosures are suitable for use as service enterance equipment.a�Does not include circuit breaker.

Order circuit breaker separately.

b�Neutral not included. Order as separate item from table on next page.

c�Neutral included in enclosure.d�Will not accept breaker with shunt trip.e�Will not accept 2 pole GFP or breaker with shunt trip.f�Includes 100% rated breakers.

Type 3R Number Maximum WeightFigure Breaker of Current Catalog Lb./Ship. Dimensions (inches)

Number Frame Poles Rating Number Package A B C D E F G H

2 QP, QPH 1–2 0060 W0204ML1060e 0 28 081⁄8 051⁄8 043⁄8 — — — — —

2 QPP, QPPH, HQPP 1–4 0225 W0406ML1225CUd 024 231⁄8 101⁄2 045⁄16 20 071⁄2 115⁄16 051⁄4 —

2 QP, QPH, 3 0100 W0303ML3100d 00 9 171⁄8 073⁄8 045⁄16 141⁄8 041⁄2 11⁄8 0311⁄16 — HQP

2 BQ, BQH, 3 0050 WB3100d 00 9 171⁄8 073⁄8 045⁄16 141⁄8 041⁄2 11⁄8 0311⁄16 — HBQ 3 100

2 NGG 2-3 125 GG0123RN 15 193⁄4 09 05 169⁄16 06 11⁄4 041⁄2 —

5 ED2, ED4, ED6, 2–3 0100 E2N3Rc 0 12 179⁄16 071⁄4 051⁄4 1239⁄64 051⁄4 1 03 — HED4, HED6

5 CED6, ED2, ED4, ED6 2–3 0125 CED6N3Rc 0 16 2221⁄64 071⁄4 051⁄4 173⁄8 051⁄4 1 03 —

FXD6, FD6, FXD6, 1 FD6, HFD6, HFXD6, 2–3 0250 F6N3Rb 0 45 381⁄8 141⁄16 073⁄4 339⁄32 08 513⁄16 131⁄2 513⁄16

HHFD6, CFD6

JXD2, JD6, f JXD6, HJD6, 1 HJXD6, HHJD6, 2–3 0400 J6N3Rb 126 4063⁄64 263⁄4 1123⁄32 353⁄4 181⁄4 21⁄8 241⁄2 11⁄8 HHJXD6, SJD6, SHJD6

LD6, LXD6, f LXD6H, HLD6,

1 HLXD6, HHLD6, 2–3 0600 LD6N3Rb 137 4563⁄64 263⁄4 1123⁄32 403⁄4 181⁄4 21⁄8 241⁄2 11⁄8 HHLXD6, CJD6, CLD6, SCJD6, SLD6, SHLD6

4 LMXD6, LMD6, 2–3 0800 LMD3Rb 210 619⁄64 263⁄4 1123⁄32 5717⁄32 181⁄4 21⁄8 245⁄8 11⁄16 HLMXD6, HLMD6

MD6, MXD6, SMD6, f HMD6, HMXD6, SHMD6, ND6, NXD6, 1 SND6, HND6, HNXD6, 2–3 1200 MND63b 210 619⁄64 263⁄4 1123⁄32 5717⁄32 181⁄4 21⁄8 245⁄8 11⁄16

SHND6, CMD6, SCMD6, CND6,SCND6

Page 4: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

6-11Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

6ENCLOSED CIRCUIT BREAKERS

Siemens / Speedfax Previous folio: 5-11 Updated by TA 03/22/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Type 3R Selection / Dimension

For inches / millimeters conversion, see Application Data section.a�Neutral not included. Order as separate item from table

on next page.

b�Neutral included in enclosure.c��Use CED enclosure for all ED-frame 110-125

ampere units.d�200% neutrals are also available. See listing on page 6-9.

e�For applications requiring 600MCM neutral conductors (3) in, (3) out (#4-600 kcmil Cu/Al) use neutral catalog number W41123.

Figure 4 Figure 5

Neutralsd

Neutral Enclosure Catalog Catalog Neutral Cable Capacity Number Number and Wire Range

(1 PC.) #14-2/0 Cu/Al, (1 pc.) #1-300 kcmil Cu/AlN125GG GG0123RN Grd. Lug (1 pc.) #12 - #4 Cu/Al (3 pcs.)#12 - #10 Cu/Al

(1 pc.) #4 - 2/0 Cu/Al

N225QJ WB2225 (1 pc.) #1 - 300 kcmil Cu/Al

WB3225

Gnd. Lug (1pc.) #14 - #4 & (3 pcs.) #14 - #10 Cu or (1 pc.) #12 - #4 & (3 pcs.) #12 - #10 Al

W53045b E2N3R (1 pc.) #14–2 Cu/Al

CED6N3Rc Grd. Lug (1 pc.) #14–8 Cu/Al

N250d F6N3R (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al

(1 pc.) #1/0–750 kcmil Cu/Al orW60992d J6N3R (2 pcs.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

W60993d LD6N3R (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

W63623 LMD3R (4 pcs.) 250 kcmil–500 kcmil Cu/Ale

MND63 Grd. Lug (1 pc.) #6–300 kcmil Cu/Al

Hubs — see page 6-14.

Dimensions

Number Maximum WeightFigure Breaker of Current Catalog Lb./Ship. Dimensions (inches)

Number Frame Poles Rating Number Package A B C D E F G H J K L M QJ2, QJH2, 2 225 WB2225 17 27 5 0711⁄16 21⁄4 2 27⁄8 20 41⁄8 35⁄8 23⁄4 23⁄4 —6 QJ2-H 3 225 WB3225 17 27 55⁄8 103⁄8 21⁄4 2 27⁄8 20 41⁄8 51⁄8 23⁄4 23⁄4 41⁄2

Page 5: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog6-12

6EN

CLOS

ED

CIRC

UIT

BREA

KERS

Siemens / Speedfax Previous folio: 5-12 Updated by TA 03/23/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Types 4, 4X, 7, and 9 Selection / Dimensions

NeutralsNeutral Enclosure Neutral Cable Capacity Catalog Number Catalog Numberb and Wire Range

W53045c ED6SS4 (1 pc.) #14–2 Cu/Al Grd. Lug (1 pc.) #14–8 Cu/Al

N250df FD6SS4 (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al

W60993df LD6SS4 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

Figure 2 Types 7 and 9e

Number Maximum Weight

Dimensions (inches) Knockouts

Breaker of Current Catalog Lb./Ship. Mounting Inside Outside Conduit Size

Frame Poles Rating Numberdf Package A B C D E F G H K Std. Max

ED2, ED4, 015–60 EA n 027 051⁄2 131⁄8 0515⁄16 103⁄4 57⁄16 097⁄16 141⁄4 65⁄8 15⁄8 11⁄4 11⁄4ED6, 2–3 070–100 EB n 032 06 18 061⁄2 16 59⁄16 097⁄8 193⁄8 611⁄16 2 2 2 HED4

CED6 2–3 100 N/A

FXD6, FD6, HFD6, 2–3 250 EC2  n 085 101⁄4 225⁄8 113⁄4 20 61⁄2 153⁄8 237⁄8 81⁄4 23⁄4 21⁄2 2HFXD6, CFD6

JXD2, JXD6, JD6, SJD6, 2–3 200–350 EC4  n 085 101⁄4 225⁄8 113⁄4 20 61⁄2 153⁄8 237⁄8 81⁄4 23⁄4 21⁄2 3HJD6, HJXD6, 300–400 EE  n 093 081⁄2 271⁄8 103⁄4 241⁄8 73⁄4 137⁄8 271⁄4 99⁄16 4 3 4HHJD6, HHJXD6, SHJD6

LXD6, LD6, SLD6, HLD6, 2–3 600 ED6  n 190 117⁄8 403⁄4 133⁄8 377⁄8 77⁄8 181⁄8 425⁄8 97⁄8 35⁄8 4 4HLXD6, HHLD6, HHLXD6, SHLD6

Dimensions

Figure 2Figure 1A Figure 1B

For inches / millimeters conversion, see Application Data selection.Note: Above enclosures are suitable for use as service entrance equipment.n Built to order. Allow 2–3 weeks for delivery.a�Does not include circuit breaker.

Order circuit breaker separately.

b�Enclosures shipped with handle and breaker hardware packaged within enclosure.

c�Neutral included.d�Neutral not included. Order as separate item.e�Breather and drain option is by SPECIAL ORDER only —

add $70.00 to list price.

f�For 400A max. 4/4x applications which require a 200% Neutral. See listing on page 6-9.

g��Suitable for use as Service Entrance device.h��Includes 100% rated breakers.i��Non-metallic enclosure.j��304 Stainless Steel enclosures.��316 Stainless Steel enclosures.

Figure 1 Types 4 and 4X

Breaker Frame

See Figure Drawing

Number of Poles

Maximum CurrentRating

Catalog Numbera

WeightLb./ShipPackage

Dimensions (inches)

A B C D E F G

NGGi 1A 2–3 125 GG0124XN 19¼ 17¼ 09½ — 035⁄8 35⁄8 18¾ED2, ED4, ED6, j

HED4 1A 3 125 ED6SS4g 44 20 16 06 075⁄32 09¾ 3 —

ED2, ED4, ED6, HED4 1B 3 125 ED6S4j 19 16.27 17.46 — 09.17 — 5.33 6.12ED2, ED4, ED6, HED4 1B 3 125 ED6S4316 19 16.27 17.46 — 09.17 — 5.33 6.12FXD6, FD6, j

HFD6, FXD6, FD6 1A 2–3 250 FD6SS4g 106 36 24 08 095⁄32 11¾ 3 —

JXD2, JXD6, JD6, hj

HJD6, HJXD6, HHJD6,HHJXD6, SJD6, SHJD6, LXD6, LD6, HLD6, HLXD6, HHLD6, HHLXD6, SLD6, SHLD6

1A 2–3 600 LD6SS4 ng 145 42 30 10 115⁄32 13¾ 3 —

• Revised •06/06/14

Page 6: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

6-13Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

6ENCLOSED CIRCUIT BREAKERS

Siemens / Speedfax Previous folio: 5-13 Updated by TA 03/23/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Types 5, 12 and 12K Selection / Dimensions

Figure 1

Figure 2 Figure 3

Figure 4

NeutralsNeutral Enclosure Catalog Catalog Neutral Cable Capacity Number Number and Wire Range

W53045d E2N12 (1 pc.) #14–2 Cu/Al

CED6N12e (1 pc.) #14–2 Cu/Al

N250cf F6N12 (1 pc.) #6–350 kcmil Grd. Lug (1 pc.) #14–2/0 Cu/Al

(1 pc.) #1/0–750 kcmil Cu/Al orW60992cf J6N12 (2 pc.) #1/0–300 kcmil Cu/Al Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

W60993cf L6N12 (2 pcs.) #1/0–600 kcmil Grd. Lug (1 pc.) #6–250 kcmil Cu/Al

W63623c LMD612 (4 pcs.) 250 kcmil–500 kcmil Cu/Al

MND612 Grd. Lug (1 pc.) #6–300 kcmil Cu/Al

Dimensions

Types 5, 12 and 12K Number Maximum WeightFigure Breaker of Current Catalog Lb./Ship. Dimensions (inches)

Number Frame Poles Rating Numberb Package A B C D E F

2 ED2, ED4, ED6, 2–3 0100 E2N12ad 012 185⁄8 0811⁄32 071⁄16 18 061⁄16 1⁄2 HED4

1 CED6, ED2, ED4, ED6 2–3 0125 CED6N12adn 016 233⁄8 0811⁄32 071⁄16 223⁄4 061⁄16 1⁄2

2 FXD6, FD6, FXD6, 2–3 0250 F6N12ac 040 3819⁄32 1429⁄64 081⁄8 34 13 23⁄32 FD6, HFD6, CFD6

JXD2, JD6, JXD6,

3 HJD6, HJXD6, 2–3 0400 J6N12 104 411⁄2 215⁄8 117⁄8 375⁄32 203⁄8 5⁄8 HHJD6, HHJXD6, SJD6, SHJD6

LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6,3 SLD6, SHLD6, CJD6,

2–3 0600 LD6N12  n 104 461⁄2 215⁄8 117⁄8 425⁄32 203⁄8 5⁄8 CLD6, SCJD6, SCLD6

4 LMXD6, LMD6, 2–3 0800 LMD12  n 220 60 373⁄8 10 3⁄8 3 2 HLMXD6, HLMD6

MD6, MXD6, SMD6, h

HMD6, HMXD6, SHMD6,4 ND6, NXD6, SND6, HND6, 2–3 1200 MND612cn 220 60 373⁄8 10 005⁄8 3 2 HNXD6, SHND6, CMD6, SCMD6, CND6, SCND6

For inches/millimeters conversion, see Application Data section.n Built to order. Allow 2–3 weeks for delivery.Note: All above enclosures are suitable for use as service entrance devices.

a�Catalog Number is for Type 12. If Type 12K with knockouts is required, add suffix “K” to catalog number.

b�Does not include circuit breaker.Order circuit breaker separately.

c�Neutral not included. Order as separate item.d�Neutral included in enclosure.

e�Use CED enclosure for all ED-frame 110–125 ampere units.

f�200% neutrals are also available. See listing on page 6-9.g�For 600 MCM neutral cable (3) in, (3) out (#4-600 kcmil Cu/

Al) use catalog number W411239h �Includes 100% rated breakers.

Page 7: Enclosed Circuit Breakers - Intelligent Infrastructure - … Neutral included in enclosure. d Will not accept breaker with shunt trip. e Will not accept 2 pole GFP or breaker with

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog6-14

6EN

CLOS

ED

CIRC

UIT

BREA

KERS

Siemens / Speedfax Previous folio: 5-14 Updated by TA 02/10/11

Product Category MCCB

Enclosed Circuit BreakersEnclosures — Knockout and Hub Data Dimensions

Hubs (Type 3R) Conduit Breaker Size Catalog Frame (inches) Number

03⁄4 ECHS075

QP, QPH, HQP, 1 ECHS100

BQ, BQH, HBQ, 11⁄4 ECHS125

NGG 11⁄2 ECHS150 2 ECHS200

11⁄4 ECHS125QPP, QPPH, HQPP, 11⁄2 ECHS150QJ2, QJH2, QJ2-H 2 ECHS200 21⁄2 ECHS250

03⁄4 ECHR075ED2, ED4, ED6, 1 ECHR100HED4, HED6, HHED6, 11⁄4 ECHR125CED6 11⁄2 ECHR150 2 ECHR200

FXD6, FD6, HFD6, HFXD6, 2 ECHV200CFD6, JXD2, JD6, 21⁄2 ECHV250JXD6, HJD6, HJXD6, 3 ECHV300LD6, LXD6, HLD6, 31⁄2 ECHV350HLXD6(A) 4 ECHV400

For inches / millimeters conversion, see Application Data section.a�Type 12K only.b�Type 12K enclosure has no knockouts this location.

c�171⁄8" high enclosure provides sufficient wire bending space for all available CB lugs.

d�Sufficient wire bending space is provided for all available mechanical type CB lugs.

e�The use of cables larger than those listed below may violate NEC & UL wire bending space requirements.

f�The use of compression type connectors will violate NEC and UL wire bending space requirements.

Knockouts & Wire Bending Space Types 1, 12 and 12K Type 3R

Number of Knockouts Per Panel (Type 4, 4X, 12 have no KO’s)

Conduit Range Maximum Maximum Cable Sizes Per Knockout Hub Size Recommended (Cu/Al) Breaker Outside Dimensions (inches) for Type 1, 3R, 4, 4X, Frame (inches) Top Bottom Side Back Bottom Side Back Type 3R 12 & 12K Enclosurese f

QP, QPH, HQP 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2 4 4 4 4 3 1 1 2 71⁄8" high encl. #6c

15–125

BQ, BQH, HBP 3⁄4, 1, 11⁄4 1 1 2 2 8 1 3 2 d

70–100

QPP, QPPH, HQPP 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2 — — — — 4 1 1 21⁄2 250 kcmil125–225

QJ 11⁄2, 2, 21⁄2, 3 2 2 2 2 3 1 1 21⁄2 d

NGG 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2 — — — — — — — —

ED2, ED4, ED6, 7⁄8, 11⁄8, 13⁄8, 13⁄4, 2 2 2 2 2 2 1 1 2 d

HED4

CED6 7⁄8, 11⁄8, 13⁄8, 13⁄4, 2 2a 2a — — 2 — —

2 d(CFD6 only 300 kcmil) 7⁄8, 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2 2 2 2b 2b — 1 1

FXD6, FD6, FXD6, FD6 11⁄8, 13⁄8, 13⁄4, 2, 21⁄2, 3

1 1 2b 2b 1 1 — 4 d

HFD6, CFD6 1 1 — — 1 — —

JXD2, JXD6, JD6, HJD6, HJXD6, HHJD6, 11⁄2, 2, 21⁄2, 3, 31⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmilHHJXD6, SJD6, SHJD6

LXD6, LD6, HLXD6, HLD6, HHLD6, HHLXD6, 11⁄2, 2, 21⁄2, 3, 31⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmilSLD6, SHLD6

LMXD6, LMD6 — — — — — — — — 4 (3) 600 kcmilHLMXD6, HMLD6

MD6, SMD6, HMD6 — — — — — — — — 4 (3) 600 kcmil or

ND6, SND6, HND6 (4) 500 kcmil

Note: Enclosures for 250A max breakers have a hub provision on the rainshed. Enclosures for larger breakers (J, L, M & N frame) have blank top rainsheds. Drill or punch hole in the field to accommodate hub size desired.