Test Certificate A sample of the following product received on April 3, 2008 and April 25, 2012 and tested on April 3, 4 and 5, 2008 and April 25, 2012 complied with the requirements of, EN 301 489-1 V1.8.1 “Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements”
EN 301 489-17 V2.1.1 “Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems”
given the measurement uncertainties as detailed in Elliott report R87501.
Summit Data Communications
Model 802.11a/g Compact Flash Module (Model: SDC-CF10AG) _____________________ _______________________ Mark E Hill Summit Data Communications Staff Engineer _______________________ Printed Name
Elliott Laboratories is accredited by the A2LA, certificate number 0214.26, to perform the test(s) listed in this report, except where noted otherwise. This report and the information contained herein represent the results of testing test articles identified and selected by the client performed to specifications and/or procedures selected by the client. National Technical Systems (NTS) makes no representations, expressed or implied, that such testing is adequate (or inadequate) to demonstrate efficiency, performance, reliability, or any other characteristic of the articles being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS of the equipment tested, nor does it represent any statement whatsoever as to its merchantability or fitness of the test article, or similar products, for a particular purpose. This report shall not be reproduced except in full
Elliott Laboratories, LLC an NTS Company 41039 Boyce Road 510-578-3500 Phone www.elliottlabs.com Fremont, CA. 94538 510-440-9525 Fax
EMC Test Report
EN 301 489-1 v1.8.1 EN 301 489-17 V2.1.1
Model: 802.11a/g Compact Flash Module (Model: SDC-CF10AG)
COMPANY: Summit Data Communications 526 South Main St. Suite 805 Akron, OH 44311 TEST SITE(S): Elliott Laboratories 684 West Maude Ave. Sunnyvale, CA. 94085 AND: 41039 Boyce Road. Fremont, CA. 94538-2435 REPORT DATE: May 24, 2012 FINAL TEST DATES: April 3, 4 and 5, 2008 and April 25, 2012 TOTAL NUMBER OF PAGES: 32 PROGRAM MGR / QUALITY ASSURANCE DELEGATE / TECHNICAL REVIEWER: FINAL REPORT PREPARER: ______________________________ ______________________________ Mark E Hill David Guidotti Staff Engineer Senior Technical Writer
Elliott Laboratories is accredited by the A2LA, certificate number 0214.26, to perform the test(s) listed in this report, except where noted otherwise. This report and the information contained herein represent the results of testing test articles identified and selected by the client performed to specifications and/or procedures selected by the client. National Technical Systems (NTS) makes no representations, expressed or implied, that such testing is adequate (or inadequate) to demonstrate efficiency, performance, reliability, or any other characteristic of the articles being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS of the equipment tested, nor does it represent any statement whatsoever as to its merchantability or fitness of the test article, or similar products, for a particular purpose. This report shall not be reproduced except in full
File: R87501 Page 2
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
REVISION HISTORY Rev# Date Comments Modified By
- 05-24-2012 First release
File: R87501 Page 3
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
TABLE OF CONTENTS
REVISION HISTORY ................................................................................................................................................ 3
TABLE OF CONTENTS ............................................................................................................................................ 4
SCOPE .......................................................................................................................................................................... 5
OBJECTIVE ................................................................................................................................................................ 5
STATEMENT OF COMPLIANCE ........................................................................................................................... 6
DEVIATIONS FROM THE STANDARD ................................................................................................................ 6
TEST RESULTS .......................................................................................................................................................... 7 EMISSIONS TESTING ............................................................................................................................................ 7 IMMUNITY TESTING ............................................................................................................................................ 8
MEASUREMENT UNCERTAINTIES ..................................................................................................................... 9
EQUIPMENT UNDER TEST (EUT) DETAILS .................................................................................................... 10 GENERAL .............................................................................................................................................................. 10 OTHER EUT DETAILS ......................................................................................................................................... 10 EUT CLASSIFICATION ....................................................................................................................................... 10 ENCLOSURE ......................................................................................................................................................... 10 MODIFICATIONS ................................................................................................................................................. 10 SUPPORT EQUIPMENT ....................................................................................................................................... 11 EUT INTERFACE PORTS .................................................................................................................................... 11 EUT OPERATION DURING IMMUNITY TESTING ......................................................................................... 11 EUT PERFORMANCE CRITERIA ....................................................................................................................... 11
IMMUNITY TEST DESCRIPTIONS ..................................................................................................................... 12 GENERAL INFORMATION ................................................................................................................................. 12
MEASUREMENT INSTRUMENTATION ............................................................................................................ 12 ELECTROSTATIC DISCHARGE TEST SYSTEM .............................................................................................. 12 ELECTROMAGNETIC FIELD TEST SYSTEM .................................................................................................. 12 INSTRUMENT CALIBRATION ........................................................................................................................... 12
IMMUNITY TEST PROCEDURES ....................................................................................................................... 13 EQUIPMENT PLACEMENT ................................................................................................................................ 13 APPLICATION OF ELECTROSTATIC DISCHARGES ..................................................................................... 13 APPLICATION OF ELECTROMAGNETIC FIELD ............................................................................................ 13
APPENDIX A TEST EQUIPMENT CALIBRATION DATA .............................................................................. 14
APPENDIX B TEST DATA LOG SHEETS ........................................................................................................... 16
END OF REPORT .................................................................................................................................................... 32
File: R87501 Page 4
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
SCOPE The European Committee for Electrotechnical Standardization (CENELEC), the European Telecommunications Standards Institute (ETSI) and the International Electrotechnical Commission (IEC) publish standards regarding the electromagnetic compatibility of electronic devices. Electromagnetic compatibility tests have been performed on the Summit Data Communications model 802.11a/g Compact Flash Module (Model: SDC-CF10AG) in accordance with these standards. The tests were performed in accordance with the current, published versions of the basic standards referenced in the following standards, as outlined in Elliott Laboratories test procedures. The test data has been provided as an appendix to this report for reference. Standard Title Date EN 301 489-1 Electromagnetic compatibility and Radio spectrum
Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements
2008-04 (V1.8.1)
EN 301 489-17 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems
2009-05 (V2.1.1)
Note, the 802.11a/g Compact Flash Module (Model: SDC-CF10AG) was tested previously against the requirements of EN 301 489-1, V1.6.1 and EN 301 489-17, V1.2.1. Refer to Elliott report R71331, dated April 10, 2008.
OBJECTIVE
The objective of the manufacturer is to declare conformity with one of the essential requirements of the R&TTE Directive 1999/5/EC. In order to demonstrate compliance, the manufacturer or a contracted laboratory makes measurements and takes the necessary steps to ensure that the equipment complies with the appropriate technical standards.
File: R87501 Page 5
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
STATEMENT OF COMPLIANCE The tested sample of Summit Data Communications model 802.11a/g Compact Flash Module (Model: SDC-CF10AG), given the performance criteria as specified by the manufacturer, complied with the requirements of the following standard(s):
Standard/Regulation Version Standard Date EN 301 489-1 1.8.1 2008-04 EN 301 489-17 2.1.1 2009-05
The test results recorded herein are based on a single type test of the Summit Data Communications model 802.11a/g Compact Flash Module (Model: SDC-CF10AG) and therefore apply only to the tested sample. The sample was selected and prepared by Sue White of Summit Data Communications Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product that could result in increased emissions should be checked to ensure compliance has been maintained (i.e., printed circuit board layout changes, different enclosure, different line filter or power supply, harnessing and/or interface cable changes, etc.).
DEVIATIONS FROM THE STANDARD
No deviations were made from the referenced standards.
File: R87501 Page 6
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
TEST RESULTS
The following tests were performed on the Summit Data Communications model 802.11a/g Compact Flash Module (Model: SDC-CF10AG). The results are based upon performance criteria defined by the manufacturer. The actual test results and associated performance criteria are contained within an appendix of this report.
EMISSIONS TESTING
Test Port Basic
Standard Level
(Margin) Status
Radiated Emissions 30MHz – 6GHz Enclosure EN 55022 -
N/A - Error! Reference source not
found.
Conducted Emissions 0.15 – 30MHz
AC Power
EN 55022 -
N/A - Error! Reference source not
found.
Harmonic Current Emissions EN 61000-3-2 -
N/A - Error! Reference source not
found.
Voltage Fluctuations EN 61000-3-3 -
N/A - Error! Reference source not
found.
Conducted Emissions 0.15 – 30MHz DC Power EN 55022 -
N/A - Error! Reference source not
found.
Conducted Emissions 0.15 – 30 MHz
Telecommunications Ports EN 55022 -
N/A - Error! Reference source not
found.Note 1 The EUT is a radio module. Compliance with the above requirements would be dependent on the
host system and would be covered when the host system is evaluated.
File: R87501 Page 7
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
IMMUNITY TESTING
Test Basic Standard Level Required Level Tested Criterion
Met Status ElectroStatic Discharge EN 61000-4-2 4 kV CD,
8 kV AD 4 kV CD, 8 kV AD A / TT / TR Complied
Radio frequency Electromagnetic Field EN 61000-4-3
80-1000 MHz 1400-2700 MHz
3 V/m 80% 1 kHz AM
80-1000 MHz 1400-2700 MHz 3
V/m 80% 1 kHz AM
A / CT / CR Complied
Fast Transients AC Power Ports EN 61000-4-4 1 kV N/A – Note 1
Fast Transients DC Power Ports EN 61000-4-4 1kV N/A – Note 1
Fast Transients Telecommunications / Signal / Control Ports
EN 61000-4-4 0.5kV N/A – Note 2
Surge, AC Power Port EN 61000-4-5 2kV CM / 1kV DM N/A – Note 1 Surge Transients Telecommunications Ports ( indoor cables)
EN 61000-4-5 0.5kV N/A – Note 2
Surge Transients Telecommunications Ports (outdoor cables)
EN 61000-4-5 1.0kV N/A – Note 2
Vehicular Surges ISO 7637-1, ISO 7637-2 N/A - Note 3
Radio Frequency Common Mode AC Power Ports
EN 61000-4-6
0.15-80 MHz, 3 Vrms
80% 1 kHz AM
N/A – Note 1
Radio Frequency Common Mode DC Power Ports
EN 61000-4-6 N/A – Note 1
Radio Frequency Common Mode Telecommunications/ Signal / Control Ports
EN 61000-4-6 N/A – Note 2
Voltage Dips and Interrupts EN 61000-4-11
100%/ ½-cycle 100%/ 1-cycle 30% /25-cycles
100%/250-cycles
N/A – Note 1
Note 1 The EUT is powered directly from a host system. Testing not performed. Note 2 The EUT does not have any signal ports that are intended to connect to cables longer than 3m in length,
or connect to outdoor cables. Note 3 The EUT is not intended to be used in a vehicular environment
File: R87501 Page 8
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
MEASUREMENT UNCERTAINTIES ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the test results be included in the report. The measurement uncertainties given below are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a 95% confidence level and were calculated in accordance with NAMAS document LAB 34. For emissions tests, the uncertainties were calculated using the approach described in CISPR 16-4-2:2003 and the levels were found to be below levels of Ucispr and therefore no adjustment of the data for measurement uncertainty is required.
Measurement Type Measurement Unit Frequency Range Expanded Uncertainty
Conducted Emissions dBuV 0.15 to 30 MHz ± 2.4 dB Radiated Emissions dBuV/m 30 to 1000 MHz ± 3.6 dB AC Current Harmonics Amps 50 to 2,000 Hz ± 0.12 %
AC Voltage Flicker Voltage N/A ± 0.12 % Pst, Plt N/A ± 3.46 %
Radiated Immunity V/m 80 – 2500 MHz - 26.3%, + 29.97% ESD KV N/A ± 8.6%
Fast Transients Voltage N/A ± 5.98 % Timing N/A ± 8.60 %
Surge Voltage N/A ± 4.92 % RF Common Mode (CDN method) Vrms 0.15 –80 MHz -12.64 %, +13.33 % RF Common Mode (BCI method) Vrms 0.15 –80 MHz -13.45 %, +15.32 %
Voltage Dips Voltage N/A ± 2.32 % Timing N/A ± 0.08mS
File: R87501 Page 9
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
EQUIPMENT UNDER TEST (EUT) DETAILS GENERAL
The Summit Data Communications model 802.11a/g Compact Flash Module (Model: SDC-CF10AG) is a wireless local area network (802.11 or Wi-Fi) module that is designed to provide wireless communications to a handheld computer. Since the EUT would be placed on a table top during operation, the EUT was treated as table-top equipment during testing to simulate the end-user environment. The EUT power is normally supplied by a host system. The sample was received on April 3, 2008 and April 25, 2012 and tested on April 3, 4 and 5, 2008 and April 25, 2012. The EUT consisted of the following component(s):
Company Model Description Serial Number FCC ID
Summit Data Communication
s
802.11a/g Compact Flash
Module (Model:SDC-
CF10AG)
module CF10AG07122- 0000376
(tested in 2008)
TWG-SDCCF1AG
Summit Data Communication
s
802.11a/g Compact Flash
Module (Model:SDC-
CF10AG)
module CF10AG1011010073
(Tested in 2012)
TWG-SDCCF1AG
OTHER EUT DETAILS
The following EUT details should be noted: The EUT was tested in the transmit and non-transmit modes.
EUT CLASSIFICATION
The radio module is designed to be installed into hosts systems that could be classified as either portable or fixed.
ENCLOSURE
The EUT does not have an enclosure as it is designed to be installed within the enclosure of a host computer or system.
MODIFICATIONS
The EUT did not require modifications during testing in order to comply with the immunity specification.
File: R87501 Page 10
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
SUPPORT EQUIPMENT
The following equipment was used as local support equipment for immunity testing:
Tested in 2008 Manufacturer Model Description Serial Number
Hp iPAQ PDA 00039-146-717-467 Sycard CFextend160B Compact Flash Extender C169B-6283
Tested in 2012
Manufacturer Model Description Serial Number FCC ID HP iPaq handheld computer - -
The following equipment was used as remote support equipment for immunity testing:
Tested in 2008 Manufacturer Model Description Serial Number
Cisco 1130AG WiFi Wireless AP FTX1040T17J
Tested in 2012 Manufacturer Model Description Serial Number FCC ID
Airlink AR430W wireless router 30008256167 RRK-AR430W
EUT INTERFACE PORTS
The I/O cabling configuration during immunity testing was as follows:
Port Connected To Cable(s) Description Shielded or Unshielded Length(m)
AC Power (host) AC Mains 2 wire unshielded 2
EUT OPERATION DURING IMMUNITY TESTING
During immunity test the EUT was exercised by pinging a wireless access point. Normal operation is indicated by continuous ping return and shall be monitored by computer screen via video camera. During testing in transceiver mode:
EUT PERFORMANCE CRITERIA
Criterion A /CT / CR: During and after testing the EUT shall continue to ping in TX mode and not to unintentionally transmit in Standby mode.
File: R87501 Page 11
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
IMMUNITY TEST DESCRIPTIONS GENERAL INFORMATION
Final tests were performed at the Elliott Laboratories Test Sites located at 684 West Maude Ave. Sunnyvale, CA 94085 and 41039 Boyce Road, Fremont, CA 94538-2435. Considerable engineering effort has been expended to ensure that the facilities conform to all pertinent CENELEC and IEC standards.
MEASUREMENT INSTRUMENTATION ELECTROSTATIC DISCHARGE TEST SYSTEM
An ESD generator is used for all testing. It is capable of applying electrostatic discharges in both contact discharge mode to 8 kV and air discharge mode to 16.5 kV in both positive and negative polarities in accordance with the EN 61000-4-2 basic EMC publication.
ELECTROMAGNETIC FIELD TEST SYSTEM
A signal generator and power amplifiers are used to provide a signal at the appropriate power and frequency to an antenna to obtain the required electromagnetic field at the position of the EUT in accordance with the EN 61000-4-3 basic EMC publication.
INSTRUMENT CALIBRATION
All test equipment is regularly checked to ensure that performance is maintained in accordance with the company's specifications. An appendix of this report contains the list of test equipment used and calibration information.
File: R87501 Page 12
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
IMMUNITY TEST PROCEDURES EQUIPMENT PLACEMENT
EN 61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement. For tabletop equipment, a 1.6 by 0.8 meter metal sheet is placed on the table and connected to the ground plane via a metal strap with two 470 kOhm resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5 millimeter thick insulating material. EN 61000-4-3 specifies that a tabletop EUT be placed on a non-conducting table 80 centimeters above a ground reference plane and that floor-mounted equipment shall be placed on an insulating support approximately 10 centimeters above a ground plane. During the EN 61000-4-3 tests, the EUT is positioned in a shielded anechoic test chamber to reduce reflections from the internal surfaces of the chamber. During the EN 61000-4-4 tests, the EUT is positioned over a ground reference plane or in a shielded chamber in conformance with this requirement.
APPLICATION OF ELECTROSTATIC DISCHARGES
The points of application of the test discharges directly to the EUT are determined after consideration of the parts of the EUT that are accessible to the operator during normal operation. Contact and air discharges are applied to the EUT, contact discharges to conducting surfaces and air-gap discharges to insulating surfaces. Contact discharges are also applied to the coupling planes to simulate nearby ESD events.
APPLICATION OF ELECTROMAGNETIC FIELD
The electromagnetic field is established at the front edge of the EUT. The frequency range is swept through the frequency range of the test using a power level necessary to obtain the required field strength at the EUT. The field is amplitude modulated using a 1 kHz or 400Hz sine wave to a depth of 80% for the swept frequency test in accordance with EN 61000-4-3. The test is repeated with each of the four sides of the EUT facing the field generating antenna. For small, portable products the test is also performed with the top and bottom sides of the EUT facing the antenna.
File: R87501 Page 13
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
Appendix A Test Equipment Calibration Data T71257 ESD, 03-Apr-08 Manufacturer Description Model Asset # Cal Due
Hewlett Packard EMC Spectrum Analyzer, 9 kHz - 6.5 GHz
8595EM 787 2/19/2009
Schaffner ESD Gun NSG-435 1491 8/13/2008 Radiated Immunity, 80 - 1000 MHz, 05-Apr-08 Manufacturer Description Model Asset # Cal Due
Rohde & Schwarz Power Meter, Dual Channel NRVD 1071 6/11/2008 Rohde & Schwarz Signal Generator, 9 kHz-2.080
GHz SMY02 1302 10/29/2008
Werlatone Directional Coupler, 0.1-1000 MHz, 40dB, 500w
C6021 1533 N/A
ETS Lindgren Biconlilog Antenna 26 MHz - 3 GHz, Radiated Immunity Only
3140B 1775 N/A
Rohde & Schwarz Power Sensor, 1 uW-100 mW, DC-18 GHz, 50ohms
NRV-Z51 1797 8/21/2008
Amplifier Research Amplifier, 250W, 1000 Amps 250W1000A 1809 N/A Radiated Immunity, 80 - 2500 MHz, 5-Apr-08 Manufacturer Description Model Asset # Cal Due
Rohde & Schwarz Power Meter, Dual Channel NRVD 1071 6/11/2008 Hughes Amplifier, 2 - 4 GHz (TWT) 8020H01 1259 N/A Comtech Amplifier, 1-2 GHz (TWT) AR1929-50 1281 N/A Werlatone Directional Coupler, 1000-3000
MHz, 30dB, 100w C6710 1532 N/A
Werlatone Directional Coupler, 0.1-1000 MHz, 40dB, 500w
C6021 1533 N/A
Rohde & Schwarz Power Sensor 100 uW - 2 Watts (w/ 20 dB pad, SN BJ5155)
NRV-Z32 1536 7/12/2008
Elliott Laboratories RI, 61000-4-3 (3rd Ed.), 80MHz-2.7 GHz
Chamber #5 Verification
1560 4/15/2008
ETS Lindgren Biconlilog Antenna 26 MHz - 3 GHz, Radiated Immunity Only
3140B 1775 N/A
EMCO Antenna, Horn, 1-18 GHz (SA40-Purple)
3115 1779 4/7/2008
Anritsu Signal Generator, 100MHz-20GHz
68347C 1785 N/A
Amplifier Research Amplifier, 250W, 1000 Amps 250W1000A 1809 N/A
File: R87501 Page 14
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
T87378 Radiated Immunity, 2,500 - 2,700 MHz, 25-Apr-12 Manufacturer Description Model Asset # Cal Due
Rohde & Schwarz Power Sensor, 1 uW-100 mW, DC-18 GHz, 50ohms
NRV-Z51 1070 5/25/2012
EMCO Antenna, Horn, 1-18 GHz (SA40-Purple)
3115 1779 4/17/2014
Rohde & Schwarz Power Meter, Dual Channel, DC to 40 GHz, 100 pW to 30 W, 9 kHz to 3 GHz, 200µV to 1000V
NRVD 1787 1/5/2013
Amplifier Research Amplifier, 25w, 0.8-4.2GHz 25S1G4AM3 1805 N/A Holaday Industries Field Probe, RF, 10 kHz-1000
MHz HI-4422 1821 1/11/2013
Agilent MXG Analog Signal Generator N5181A 2146 1/27/2013 Advanced Technical Materials Inc. (ATM)
Directional Coupler, 1.0-11.0GHz, 35dB, 50w
CHP223G-35FNF 2521 N/A
Hewlett Packard EMC Spectrum Analyzer, 9 KHz-26.5 GHz
8593EM 1141 12/14/2012
File: R87501 Page 15
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
File: R87501 Page 16
Appendix B Test Data Log Sheets
ELECTROMAGNETIC EMISSIONS
TEST LOG SHEETS
AND
MEASUREMENT DATA
T71257 Pages 17 – 26 T87378 Pages 27 – 31
EMC Test Data
EN 301 489-17 v1.2.1 Class: -
SDC-CF10AG
EMC Test DataFor The
Summit Data CommunicationsModel
SDC-CF10AG T-Log Number: T71257Account Manager:
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09) Environment: WirelessEmissions Standard(s):
Dean Eriksen
Client: Summit Data Communications Job Number: J71248
Contact: Ron Seide -
Model:
Date of Last Test: 4/7/2008
R87501 Cover Page 17
EMC Test Data
Test Specific Details
General Test Configuration
4/3/2008 8:11 Config. Used:
For table-top equipment, the EUT was placed into a host system and all local support equipment were located on a 0.5-mm thick insulating layer above a horizontal coupling plane, 80 cm above a ground reference plane.
Unless otherwise stated, ten discharges at each voltage, and polarity, were applied to each test point listed. Contact discharges were applied to coupling planes and conductive surfaces of the EUT and host system. Air discharges were applied to any non-conductive surfaces of the EUT and host system. The VCP was located on the table top for table top devices and 80cm above the ground plane for floor standing equipment.The determination as to the test point being a part of a conductive or non-conductive surface was based on testing the surface for conductivity using an ohmmeter.
Test Location: ESD Lab Host Unit Voltage 120VTest Engineer: Joe What Config Change: None
ElectroStatic Discharge (EN 61000-4-2)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test:
Account Manager: Dean Eriksen
1
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09) Environment: WirelessContact: Ron Seide
Client: Summit Data Communications Job Number: J71248Model: SDC-CF10AG T-Log Number: T71257
Ambient Conditions: 21 °C38 %
1026 mb
Summary of Results
Deviations From The StandardNo deviations were made from the requirements of the standard.
Modifications Made During TestingNo modifications were made to the EUT during testing
Criteria/Result Comments
1 ESD - Enclosure 4KV Direct8KV Air
A / Pass Transmit and Receive Mode
Relative Humidity:Pressure:
Run # Test Performed Level
y g
Temperature:
R87501 ESD 03-Apr-08 Page 18
EMC Test Data
Account Manager: Dean Eriksen
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09) Environment: WirelessContact: Ron Seide
Client: Summit Data Communications Job Number: J71248Model: SDC-CF10AG T-Log Number: T71257
Run #1: Electrostatic DischargeTransmit Mode
Level 1 Level 2 Level 3 Level 4 Level 1 Level 2 Level 3 Level 42KV 4KV 6KV 8KV -2KV -4KV -6KV -8KV
X X - - X X - -
X X - - X X - -
Note 1:
Note 2:
Run #2: Electrostatic DischargeNon-Transmit Mode
ModeVCP located 10cm from the front, rear, left and right sides of the EUTHCP located 10cm from the front, rear, left and right sides of the EUT
An "X" indicates that the unit continued to operate as intended. The host system was pinging to a remote AP and the host system reported there were no data errors or loss of data.There was no direct or air discharges to the EUT because it is normally inserted into a host system and would be inaccessible while in operation.
(To Coupling Planes) (kV) (kV)
Contact
Indirect Discharges Positive Polarity Negative Polarity
o a s t ode
Level 1 Level 2 Level 3 Level 4 Level 1 Level 2 Level 3 Level 42KV 4KV 6KV 8KV -2KV -4KV -6KV -8KV
X X - - X X - -
X X - - X X - -
Note 1:
Note 2: There was no direct or air discharges to the EUT because it is normally inserted into a host system and would be inaccessible while in operation.
Positive Polarity Negative Polarity(kV) (kV)
An "X" indicates that the unit continued to operate as intended. The EUT did not unintentionally transmit, as monitored by a spectrum analyzer.
ModeVCP located 10cm from the front, rear, left and right sides of the EUTHCP located 10cm from the front, rear, left and right sides of the EUT
Indirect Discharges(To Coupling Planes)
Contact
R87501 ESD 03-Apr-08 Page 19
EMC Test Data
Account Manager: Dean Eriksen
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09) Environment: WirelessContact: Ron Seide
Client: Summit Data Communications Job Number: J71248Model: SDC-CF10AG T-Log Number: T71257
Test Configuration Photograph #1
R87501 ESD 03-Apr-08 Page 20
EMC Test Data
Account Manager: Dean Eriksen
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09) Environment: WirelessContact: Ron Seide
Client: Summit Data Communications Job Number: J71248Model: SDC-CF10AG T-Log Number: T71257
Test Configuration Photograph #2
R87501 ESD 03-Apr-08 Page 21
EMC Test Data
Test Specific Details
General Test Configuration
Ambient Conditions: 20 °C42 %
Summary of Results
The EUT and all local support equipment were located on a turntable in an anechoic chamber.
Temperature:Rel. Humidity:
EUT Voltage: 230V/50Hz
Test Engineer: Vishal Narayan Chris Groat
Config Change: None
Environment: Wireless
Radiated Immunity (EN 61000-4-3)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test: 4/4-5/2008 11:00:00 PM Config. Used: 1
T-Log Number: T71257Account Manager: Dean Eriksen
Contact: Ron Seide
Job Number: J71248Model: SDC-CF10AGClient: Summit Data Communications
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09)
Test Location: Fremont Chamber #5
A/Pass Receive Mode1 80 - 1000 MHz1kHz 80% AM
3 V/m1kHz 80% AM
Deviations From The StandardNo deviations were made from the requirements of the standard.
No modifications were made to the EUT during testing
Receive Mode1 1000 - 2500 MHz1kHz 80% AM
3 V/m1kHz 80% AM A/Pass
Transmit ModeA/Pass
Run # Test Performed Level Criteria/Result Comments
2 80 - 1000 MHz1kHz 80% AM
3 V/m1kHz 80% AM A/Pass Transmit Mode
2 1000 - 2500 MHz1kHz 80% AM
3 V/m1kHz 80% AM
Modifications Made During Testing
R87501 RI Receive & Transmit 04-Apr-08 Page 22
EMC Test Data
Environment: Wireless
T-Log Number: T71257Account Manager: Dean Eriksen
Contact: Ron Seide
Job Number: J71248Model: SDC-CF10AGClient: Summit Data Communications
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09)
Run #1: Radiated Immunity, 80 - 2500 MHz (EN61000-4-3)Receive Mode
1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A3 X X X X X X X X N/A N/A N/A N/A
Test files used for this run:
1000 - 2500
Depth / Deviation: 80%
80 - 1000
Modulation Details
Right Top BottomRange (MHz)Frequency Front Left Side Rear
The following calibration files from O:\EMC Stuff\Radiated Immunity Cal\CH5\CH5 0080 1000 MHz Nov 2006\03 Vm 80 1000 MHz\
Modulating Frequency: 1 kHzModulation: AM
Test Distance: 3
Step Size:Dwell time:
Field Uniformity: 1.5m x 1.5m
Frequency: 80 - 1000 MHz
1.55m High - centerline, 3m from tip 80 MHz - 1000 MHz H 3Vm.crf1.55m High - centerline, 3m from tip 80 MHz - 1000 MHz V 3Vm.crf
Tip 2m from uniform field, boom arm 1.55m high, 1-2GHz H 3Vm.crfTip 2m from uniform field, boom arm 1.55m high, 1-2GHz V 3Vm.crfTip 2m from uniform field, boom arm 1.55m high, 2-2.5GHz H 3Vm.crfTip 2m from uniform field, boom arm 1.55m high, 2-2.5GHz V 3Vm.crf
Note: An "X" indicates that the unit continued to operate as intended. Occasionally signal's were observed on the analyzer. Turned off the RF and the signals were still observed every couple of minutes. These signals did not seem to be transmit signals as they were occasionally seen and when the problem frequencies were test again signals were not repeatable therefore the EUT passes.
The following calibration files from O:\EMC Stuff\Radiated Immunity Cal\CH5\CH5, 0080-1000 MHz, Nov 2006\03 Vm, 80-1000 MHz\ were used:
The following calibration files from O:\EMC Stuff\Radiated Immunity Cal\Chamber #5\CH5, 1000-2500 MHz, December 2006\03 Vm, 1000-2700 MHz\ were used:
R87501 RI Receive & Transmit 04-Apr-08 Page 23
EMC Test Data
Environment: Wireless
T-Log Number: T71257Account Manager: Dean Eriksen
Contact: Ron Seide
Job Number: J71248Model: SDC-CF10AGClient: Summit Data Communications
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09)
Run #2: Radiated Immunity, 80 - 2500 MHz (EN61000-4-3)Transmit Mode
1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A3 X X X X X X X X N/A N/A N/A N/A
Test files used for this run:
Frequency: 80 - 1000 MHz
3
Modulation DetailsModulating Frequency: 1 kHz
Range (MHz)Frequency Front Left Side
Step Size:Dwell time:
AM
Field Uniformity: 1.5m x 1.5mTest Distance:
1000 - 2500
The following calibration files from O:\EMC Stuff\Radiated Immunity Cal\CH5\CH5 0080 1000 MHz Nov 2006\03 Vm 80 1000 MHz\
Depth / Deviation: 80%Modulation:
Right Top BottomRear
80 - 1000
1.55m High - centerline, 3m from tip 80 MHz - 1000 MHz H 3Vm.crf1.55m High - centerline, 3m from tip 80 MHz - 1000 MHz V 3Vm.crf
Tip 2m from uniform field, boom arm 1.55m high, 1-2GHz H 3Vm.crfTip 2m from uniform field, boom arm 1.55m high, 1-2GHz V 3Vm.crfTip 2m from uniform field, boom arm 1.55m high, 2-2.5GHz H 3Vm.crfTip 2m from uniform field, boom arm 1.55m high, 2-2.5GHz V 3Vm.crf
Note:
The following calibration files from O:\EMC Stuff\Radiated Immunity Cal\CH5\CH5, 0080-1000 MHz, Nov 2006\03 Vm, 80-1000 MHz\ were used:
An "X" indicates that the unit continued to operate as intended. The EUT continued to transmit to a communication link(Access Point) and the ping tests continued before, after and during testing.
The following calibration files from O:\EMC Stuff\Radiated Immunity Cal\Chamber #5\CH5, 1000-2500 MHz, December 2006\03 Vm, 1000-2700 MHz\ were used:
R87501 RI Receive & Transmit 04-Apr-08 Page 24
EMC Test Data
Environment: Wireless
T-Log Number: T71257Account Manager: Dean Eriksen
Contact: Ron Seide
Job Number: J71248Model: SDC-CF10AGClient: Summit Data Communications
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09)
Test Configuration Photograph #1
R87501 RI Receive & Transmit 04-Apr-08 Page 25
EMC Test Data
Environment: Wireless
T-Log Number: T71257Account Manager: Dean Eriksen
Contact: Ron Seide
Job Number: J71248Model: SDC-CF10AGClient: Summit Data Communications
Immunity Standard(s): EN301 489-1 V1.6.1 (2005-09)
Test Configuration Photograph #2
R87501 RI Receive & Transmit 04-Apr-08 Page 26
EMC Test Data
Emissions Standard(s): EN 301 489-17 v2.1.1,EN301 489-1 v1.8.1 Class: -
Client: Summit Data Communications Job Number: J87009Model: 802.11a/g Compact Flash Module (Model:SDC-
CF10AG)T-Log Number: T87378
Account Manager:
EMC Test DataFor The
Summit Data Communications
Christine KrebillContact: Sue White -
Model
Immunity Standard(s): EN 301 489-17 v2.1.1,EN301 489-1 v1.8.1 Environment: -
802.11a/g Compact Flash Module (Model:SDC-CF10AG)
Date of Last Test: 5/8/2012
R87501 Cover Page 27
EMC Test Data
Test Specific Details
General Test Configuration
Ambient Conditions: 25 °C36 %
Summary of Results-Radiated Immunity
Client: Summit Data Communications Job Number: J87009Model: 802.11a/g Compact Flash Module (Model:SDC-
CF10AG)T-Log Number: T87378
Account Manager: Christine KrebillContact: Sue White
Immunity Standard(s): EN 301 489-17 v2.1.1,EN301 489-1 v1.8.1 Environment: -
Radiated Immunity (EN 61000-4-3)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test: 4/25/2012 15:06 Config. Used: 1
230V/50Hz (host)Test Engineer: Jay Dickinson Config Change: noneTest Location: Fremont Chamber #6 EUT Voltage:
The EUT and all local support equipment were located on a turntable in an anechoic chamber. All remote support equipment was located outside the chamber. Interface cabling to the remote support equipment was routed along the floor and, where possible, passed through ferrite clamps at the exit point from the chamber.
Temperature:Rel. Humidity:
Summary of Results-Radiated Immunity
1
Required Applied Required Met / ResultRun # Port Test Level Performance Criteria Comments
EN 301 489-1 V1.8.1 Requirements
Enclosure
80-1000 MHz2.5GHz-2.7GHz1kHz 80% AM
3 V/m
80-1000 MHz2.5GHz-2.7GHz1kHz 80% AM
3 V/m
A A / Pass
Deviations From The StandardNo deviations were made from the requirements of the standard.
Modifications Made During TestingNo modifications were made to the EUT during testing
R87501 RI 25-Apr-12 Page 28
EMC Test DataClient: Summit Data Communications Job Number: J87009Model: 802.11a/g Compact Flash Module (Model:SDC-
CF10AG)T-Log Number: T87378
Account Manager: Christine KrebillContact: Sue White
Immunity Standard(s): EN 301 489-17 v2.1.1,EN301 489-1 v1.8.1 Environment: -
Run #1: Radiated Immunity, 2500-2700 MHz (EN61000-4-3)
1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A
Run #2: Radiated Immunity, 2500-2700 MHz (EN61000-4-3)
1 %Frequency: 2.5-2.7 GHz
Frequency: 2.5-2.7 GHzStep Size:
Dwell time:Field Uniformity: 1.0m x 1.0m
Test Distance: 1.25
Modulation DetailsModulating Frequency: 1 kHz
Modulation: AMDepth / Deviation: 80%
Frequency
2500-2700
Right Top BottomRange (MHz)
Front Left Side Rear
Transmit
Standby Step Size: 1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A
Test files used for Runs#1 and #2:The following calibration files from U:\EMC Stuff\RI Playback Files FT\CH6\Current\1-2.7 GHz (March 2012)\3 Vm\ were used:
1.25m from UFA, 1.25m High 1000 MHz - 2700 MHz H 3Vm.crf1.25m from UFA, 1.25m High 1000 MHz - 2700 MHz V 3Vm.crf
Note:
Test Distance: 1.251.0m x 1.0m
Right Top BottomRange (MHz)
An "X" indicates that the unit continued to operate as intended. In Transmit mode, the unit continued to ping without data errors reported by the monitoring software. While in Standby, the unit did not transmit unintentionally.
2500-2700
Modulating Frequency: 1 kHzModulation: AM
Frequency Front
Depth / Deviation: 80%
Left Side Rear
Standby Step Size:Dwell time:
Field Uniformity:
Modulation Details
R87501 RI 25-Apr-12 Page 29
EMC Test DataClient: Summit Data Communications Job Number: J87009Model: 802.11a/g Compact Flash Module (Model:SDC-
CF10AG)T-Log Number: T87378
Account Manager: Christine KrebillContact: Sue White
Immunity Standard(s): EN 301 489-17 v2.1.1,EN301 489-1 v1.8.1 Environment: -
Test Configuration Photograph #1(Radiated Immunity, EN 61000-4-3)
R87501 RI 25-Apr-12 Page 30
EMC Test DataClient: Summit Data Communications Job Number: J87009Model: 802.11a/g Compact Flash Module (Model:SDC-
CF10AG)T-Log Number: T87378
Account Manager: Christine KrebillContact: Sue White
Immunity Standard(s): EN 301 489-17 v2.1.1,EN301 489-1 v1.8.1 Environment: -
Test Configuration Photograph #2(Radiated Immunity, EN 61000-4-3)
R87501 RI 25-Apr-12 Page 31
Elliott Laboratories -- EMC Department Test Report . Report Date: May 24, 2012
End of Report
This page is intentionally blank and marks the last page of this test report.