emission testing report ingal civil products, minto plant
TRANSCRIPT
This document is confidential and is prepared for the exclusive use of Ingal Civil Products
and those granted permission by Ingal Civil Products.
Report Number R004882
Emission Testing Report
Ingal Civil Products, Minto Plant
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 2 of 8
Document Information
Client Name: Ingal Civil Products
Report Number: R004882
Date of Issue: 11 January 2018
Attention: Amit Gupta
Address: 57-65 Airds Road Minto NSW 2566 Testing Laboratory: Ektimo Pty Ltd, ABN 86 600 381 413
Report Status
Format Document Number Report Date Prepared By Reviewed By (1) Reviewed By (2)
Preliminary Report - - - - -
Draft Report R004882[DRAFT] 8/12/2017 JWe ADa SCo
Final Report R004882 11/01/2018 JWe ADa SCo
Amend Report - - - - -
Template Version: 021117
Amendment Record
Document Number Initiator Report Date Section Reason
Nil - - - -
Report Authorisation
Aaron Davis Client Manager
NATA Accredited Laboratory
No. 14601
Accredited for compliance with ISO/IEC 17025 - Testing. NATA is a signatory to the ILAC mutual recognition arrangement for the mutual
recognition of the equivalence of testing, calibration and inspection reports.
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 3 of 8
Table of Contents
1 Executive Summary ....................................................................................................................... 4
2 Results Summary ........................................................................................................................... 4
3 Results ........................................................................................................................................... 5
3.1 EPA 1 - Baghouse Stack ............................................................................................................................................. 5
4 Plant Operating Conditions ........................................................................................................... 6
5 Test Methods ................................................................................................................................ 6
6 Quality Assurance/ Quality Control Information .......................................................................... 6
7 Definitions ..................................................................................................................................... 7
8 Appendix 1. Envirolab Ammonia Report ....................................................................................... 8
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 4 of 8
1 EXECUTIVE SUMMARY
Ektimo was engaged by Ingal Civil Products to perform emission monitoring as part of the yearly requirement
stipulated in their NSW EPA Environment Protection Licence (12593).
Monitoring was performed as follows:
Location Test Date Test Parameters*
EPA 1 – Baghouse Stack 23 November 2017 Ammonia
* Flow rate, velocity, temperature and moisture were determined unless otherwise stated
The sampling methodologies chosen by Ektimo are those recommended by the NSW Office of Environment and Heritage (as specified in the Approved Methods for the Sampling and Analysis of Air Pollutants in New South Wales, January 2007).
All results are reported on a dry basis at STP. Unless otherwise indicated, the methods cited in this report have been performed without deviation.
Plant operating conditions have been noted in the report.
2 RESULTS SUMMARY
The following licence comparison table shows that all analytes highlighted in green are below the licence limit set by the NSW EPA as per licence 12593 (last amended on 5 July 2017).
EPA Parameter Units Licence limit Detected values Detected values
Test 1 Test 2
Ammonia and ammonium compounds mg/m3 2 0.67 1.8EPA 1 - Baghouse Stack
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 5 of 8
3 RESULTS
3.1 EPA 1 - Baghouse Stack
Date Client
Report Stack ID
Licence No. Location
Ektimo Staff State
Process Conditions Please refer to client records.
space space space space space space space space
Sampling Plane Details
Sampling plane dimensions
Sampling plane area
Sampling port size, number
Access & height of ports Fixed ladder 10 m
Duct orientation & shape Vertical Circular
Downstream disturbance Exit >2 D
Upstream disturbance Bend >6 D
No. traverses & points sampled 2 12
Sample plane compliance to AS4323.1
space space space space space space space space
Stack Parameters
Moisture content, %v/v 1.7
Gas molecular weight, g/g mole 28.8 (wet) 29.0 (dry)
Gas density at STP, kg/m³ 1.29 (wet) 1.29 (dry)
Flow measurement time(s) (hhmm) 1054, 1230, 1410 & 1532
Temperature, °C 39
Velocity at sampling plane, m/s 8.3
Volumetric flow rate, discharge, m³/s 9.4
Volumetric flow rate (wet STP), m³/s 8.2
Volumetric flow rate (dry STP), m³/s 8.1
Mass flow rate (wet basis), kg/hour 38000
space space space space space space space space
Isokinetic Results
Sampling time
Mass Rate Mass Rate Mass Rate
mg/m³ g/min mg/m³ g/min mg/m³ g/min
Ammonia 1.2 0.6 0.67 0.33 1.8 0.88
Isokinetic Sampling Parameters
Sampling time, min 60 60
Isokinetic rate, % 103 102
Velocity difference, % -2 1
Gas Flow Parameters
Test 1
1103-1208
Average
Concentration Concentration
2" BSP (x2)
Ideal
23/11/2017
R004882
12593
1420-1525
Concentration
Test 2
Ingal Civil Products
EPA 1 - Baghouse Stack
Minto
NSWDavid Hill & Ryan Collins
1200 mm
1.13 m²
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 6 of 8
4 PLANT OPERATING CONDITIONS
Unless otherwise stated, the plant operating conditions were normal at the time of testing. See Ingal Civil
Products’s records for complete process conditions.
5 TEST METHODS
All sampling and analysis was performed by Ektimo unless otherwise specified. Specific details of the
methods are available upon request.
1. Analysis performed by Envirolab, NATA accreditation number 2901. Results were reported to Ektimo on 5 December 2017 in report
number 180796.
6 QUALITY ASSURANCE/ QUALITY CONTROL INFORMATION
Ektimo are accredited by the National Association of Testing Authorities (NATA) for the sampling and analysis
of air pollutants from industrial sources. Unless otherwise stated test methods used are accredited with the
National Association of Testing Authorities. For full details, search for Ektimo at NATA’s website
www.nata.com.au.
Ektimo are accredited by NATA (National Association of Testing Authorities) to ISO/IEC 17025 - Testing.
ISO/IEC 17025 - Testing requires that a laboratory have adequate equipment to perform the testing, as well as
laboratory personnel with the competence to perform the testing. This quality assurance system is
administered and maintained by the Quality Director.
NATA is a member of APLAC (Asia Pacific Laboratory Accreditation Co-operation) and of ILAC (International
Laboratory Accreditation Co-operation). Through the mutual recognition arrangements with both of these
organisations, NATA accreditation is recognised world –wide.
A formal Quality Control program is in place at Ektimo to monitor analyses performed in the laboratory and
sampling conducted in the field. The program is designed to check where appropriate; the sampling
reproducibility, analytical method, accuracy, precision and the performance of the analyst. The Laboratory
Manager is responsible for the administration and maintenance of this program.
Sampling Method Analysis Method Uncertainty*
Sampling Analysis
NSW TM-1 NA - ✓ NA
NSW TM-22 NSW TM-22 8% ✓ ✓
NSW TM-2 NA 2% ✓ NA
NSW TM-2 NA 8% ✓ NA
NSW TM-2 NA 7% ✓ NA
USEPA CTM - 027 APHA 4500-NH3 not specified ✓ ✓1
Parameter NATA Accredited
Velocity
Temperature
Flow rate
Sample plane criteria
Moisture content
Ammonia
* Uncertainty values cited in this table are calculated at the 95% confidence level (coverage factor = 2)
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 7 of 8
7 DEFINITIONS
The following symbols and abbreviations may be used in this test report:
~ Approximately < Less than > Greater than ≥ Greater than or equal to APHA American public health association, Standard Methods for the Examination of Water and
Waste Water AS Australian Standard BSP British standard pipe CARB Californian Air Resources Board CEM Continuous Emission Monitoring CEMS Continuous Emission Monitoring System CTM Conditional test method D Duct diameter or equivalent duct diameter for rectangular ducts D50 ‘Cut size’ of a cyclone defined as the particle diameter at which the cyclone achieves a 50%
collection efficiency ie. half of the particles are retained by the cyclone and half are not and pass through it to the next stage. The D50 method simplifies the capture efficiency distribution by assuming that a given cyclone stage captures all of the particles with a diameter equal to or greater than the D50 of that cyclone and less than the D50 of the preceding cyclone.
DECC Department of Environment & Climate Change (NSW) Disturbance A flow obstruction or instability in the direction of the flow which may impede accurate flow
determination. This includes centrifugal fans, axial fans, partially closed or closed dampers, louvres, bends, connections, junctions, direction changes or changes in pipe diameter.
DWER Department of Water and Environmental Regulation EPA Environment Protection Authority FTIR Fourier Transform Infra Red ISC Intersociety committee, Methods of Air Sampling and Analysis ISO International Organisation for Standardisation NA Not applicable NATA National Association of Testing Authorities NIOSH National Institute of Occupational Safety and Health NT Not tested or results not required OM Other approved method OU The number of odour units per unit of volume. The numerical value of the odour
concentration is equal to the number of dilutions to arrive at the odour threshold (50% panel response).
PM10 Atmospheric suspended particulate matter having an equivalent aerodynamic diameter of less than approximately 10 microns (µm).
PM2.5 Atmospheric suspended particulate matter having an equivalent aerodynamic diameter of less than approximately 2.5 microns (µm).
PSA Particle size analysis RATA Relative Accuracy Test Audit STP Standard temperature and pressure. Gas volumes and concentrations are expressed on a dry
basis at 0°C, at discharge oxygen concentration and an absolute pressure of 101.325 kPa, unless otherwise specified.
TM Test Method TOC The sum of all compounds of carbon which contain at least one carbon to carbon bond, plus
methane and its derivatives. USEPA United States Environmental Protection Agency VDI Verein Deutscher Ingenieure (Association of German Engineers) Vic EPA Victorian Environment Protection Authority VOC Any chemical compound based on carbon with a vapour pressure of at least 0.010 kPa at 25°C
or having a corresponding volatility under the particular conditions of use. These compounds may contain oxygen, nitrogen and other elements, but specifically excluded are carbon monoxide, carbon dioxide, carbonic acid, metallic carbides and carbonate salts.
XRD X-ray Diffractometry
Ektimo 11 January 2018
Report R004882 prepared for Ingal Civil Products, Minto Page 8 of 8
8 APPENDIX 1. ENVIROLAB AMMONIA REPORT
Envirolab Services Pty Ltd
ABN 37 112 535 645
12 Ashley St Chatswood NSW 2067
ph 02 9910 6200 fax 02 9910 6201
www.envirolab.com.au
CERTIFICATE OF ANALYSIS 180796
1/251 Princes Hwy, Unanderra, NSW, 2526Address
D HillAttention
Ektimo (Unanderra)Client
Client Details
08/11/2017Date completed instructions received
08/11/2017Date samples received
7 LiquidsNumber of Samples
R004882Your Reference
Sample Details
Results are reported on a dry weight basis for solids and on an as received basis for other matrices.
Samples were analysed as received from the client. Results relate specifically to the samples as received.
Please refer to the following pages for results, methodology summary and quality control data.
Analysis Details
Tests not covered by NATA are denoted with *Accredited for compliance with ISO/IEC 17025 - Testing.
NATA Accreditation Number 2901. This document shall not be reproduced except in full.
05/12/2017Date of Issue
05/12/2017Date results requested by
Report Details
David Springer, General Manager
Authorised By
Nick Sarlamis, Inorganics Supervisor
Results Approved By
Revision No: R00
180796Envirolab Reference: Page | 1 of 6
Client Reference: R004882
0.0180.050mg/LAmmonia as N in water
<1010µgAmmonia as N in impinger
240200mLVolume
29/11/201729/11/2017-Date analysed
29/11/201729/11/2017-Date prepared
LiquidLiquidType of sample
N5907N5906UNITSYour Reference
180796-7180796-6Our Reference
Miscellaneous Inorganics
9.91.90.0503.60.32mg/LAmmonia as N in water
1,700320<1073041µgAmmonia as N in impinger
170170140200130mLVolume
29/11/201729/11/201729/11/201729/11/201729/11/2017-Date analysed
29/11/201729/11/201729/11/201729/11/201729/11/2017-Date prepared
LiquidLiquidLiquidLiquidLiquidType of sample
N5905N5904N5903N5902N5901UNITSYour Reference
180796-5180796-4180796-3180796-2180796-1Our Reference
Miscellaneous Inorganics
Envirolab Reference: 180796
R00Revision No:
Page | 2 of 6
Client Reference: R004882
Ammonia in impingers/filter pads using Discrete Analyser. Inorg-093
Ammonia - determined colourimetrically, based on APHA latest edition 4500-NH3 F. Soils are analysed following a KCl extraction.
Inorg-057
Methodology SummaryMethod ID
Envirolab Reference: 180796
R00Revision No:
Page | 3 of 6
Client Reference: R004882
10710730.330.321<0.005Inorg-0570.005mg/LAmmonia as N in water
107107543411<10Inorg-09310µgAmmonia as N in impinger
29/11/201729/11/201729/11/201729/11/2017129/11/2017-Date analysed
29/11/201729/11/201729/11/201729/11/2017129/11/2017-Date prepared
180796-2LCS-W1RPDDup.Base#BlankMethodPQLUnitsTest Description
Spike Recovery %DuplicateQUALITY CONTROL: Miscellaneous Inorganics
Envirolab Reference: 180796
R00Revision No:
Page | 4 of 6
Client Reference: R004882
Not ReportedNR
National Environmental Protection MeasureNEPM
Not specifiedNS
Laboratory Control SampleLCS
Relative Percent DifferenceRPD
Greater than>
Less than<
Practical Quantitation LimitPQL
Insufficient sample for this testINS
Test not requiredNA
Not testedNT
Result Definitions
Australian Drinking Water Guidelines recommend that Thermotolerant Coliform, Faecal Enterococci, & E.Coli levels are less than1cfu/100mL. The recommended maximums are taken from "Australian Drinking Water Guidelines", published by NHMRC & ARMC2011.
Surrogates are known additions to each sample, blank, matrix spike and LCS in a batch, of compounds whichare similar to the analyte of interest, however are not expected to be found in real samples.
Surrogate Spike
This comprises either a standard reference material or a control matrix (such as a blank sand or water) fortifiedwith analytes representative of the analyte class. It is simply a check sample.
LCS (LaboratoryControl Sample)
A portion of the sample is spiked with a known concentration of target analyte. The purpose of the matrix spikeis to monitor the performance of the analytical method used and to determine whether matrix interferencesexist.
Matrix Spike
This is the complete duplicate analysis of a sample from the process batch. If possible, the sample selectedshould be one where the analyte concentration is easily measurable.
Duplicate
This is the component of the analytical signal which is not derived from the sample but from reagents,glassware etc, can be determined by processing solvents and reagents in exactly the same manner as forsamples.
Blank
Quality Control Definitions
Envirolab Reference: 180796
R00Revision No:
Page | 5 of 6
Client Reference: R004882
Measurement Uncertainty estimates are available for most tests upon request.
Where sampling dates are not provided, Envirolab are not in a position to comment on the validity of the analysis whererecommended technical holding times may have been breached.
When samples are received where certain analytes are outside of recommended technical holding times (THTs), the analysis hasproceeded. Where analytes are on the verge of breaching THTs, every effort will be made to analyse within the THT or as soon aspracticable.
In circumstances where no duplicate and/or sample spike has been reported at 1 in 10 and/or 1 in 20 samples respectively, thesample volume submitted was insufficient in order to satisfy laboratory QA/QC protocols.
Matrix Spikes, LCS and Surrogate recoveries: Generally 70-130% for inorganics/metals; 60-140% for organics (+/-50% surrogates)and 10-140% for labile SVOCs (including labile surrogates), ultra trace organics and speciated phenols is acceptable.
Duplicates: <5xPQL - any RPD is acceptable; >5xPQL - 0-50% RPD is acceptable.
For VOCs in water samples, three vials are required for duplicate or spike analysis.
Spikes for Physical and Aggregate Tests are not applicable.
Filters, swabs, wipes, tubes and badges will not have duplicate data as the whole sample is generally extracted during sampleextraction.
Duplicate sample and matrix spike recoveries may not be reported on smaller jobs, however, were analysed at a frequency to meetor exceed NEPM requirements. All samples are tested in batches of 20. The duplicate sample RPD and matrix spike recoveries forthe batch were within the laboratory acceptance criteria.
Laboratory Acceptance Criteria
Envirolab Reference: 180796
R00Revision No:
Page | 6 of 6