emission testing report ingal civil products, minto plant

14
This document is confidential and is prepared for the exclusive use of Ingal Civil Products and those granted permission by Ingal Civil Products. Report Number R004882 Emission Testing Report Ingal Civil Products, Minto Plant

Upload: others

Post on 18-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Emission Testing Report Ingal Civil Products, Minto Plant

This document is confidential and is prepared for the exclusive use of Ingal Civil Products

and those granted permission by Ingal Civil Products.

Report Number R004882

Emission Testing Report

Ingal Civil Products, Minto Plant

Page 2: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 2 of 8

Document Information

Client Name: Ingal Civil Products

Report Number: R004882

Date of Issue: 11 January 2018

Attention: Amit Gupta

Address: 57-65 Airds Road Minto NSW 2566 Testing Laboratory: Ektimo Pty Ltd, ABN 86 600 381 413

Report Status

Format Document Number Report Date Prepared By Reviewed By (1) Reviewed By (2)

Preliminary Report - - - - -

Draft Report R004882[DRAFT] 8/12/2017 JWe ADa SCo

Final Report R004882 11/01/2018 JWe ADa SCo

Amend Report - - - - -

Template Version: 021117

Amendment Record

Document Number Initiator Report Date Section Reason

Nil - - - -

Report Authorisation

Aaron Davis Client Manager

NATA Accredited Laboratory

No. 14601

Accredited for compliance with ISO/IEC 17025 - Testing. NATA is a signatory to the ILAC mutual recognition arrangement for the mutual

recognition of the equivalence of testing, calibration and inspection reports.

Page 3: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 3 of 8

Table of Contents

1 Executive Summary ....................................................................................................................... 4

2 Results Summary ........................................................................................................................... 4

3 Results ........................................................................................................................................... 5

3.1 EPA 1 - Baghouse Stack ............................................................................................................................................. 5

4 Plant Operating Conditions ........................................................................................................... 6

5 Test Methods ................................................................................................................................ 6

6 Quality Assurance/ Quality Control Information .......................................................................... 6

7 Definitions ..................................................................................................................................... 7

8 Appendix 1. Envirolab Ammonia Report ....................................................................................... 8

Page 4: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 4 of 8

1 EXECUTIVE SUMMARY

Ektimo was engaged by Ingal Civil Products to perform emission monitoring as part of the yearly requirement

stipulated in their NSW EPA Environment Protection Licence (12593).

Monitoring was performed as follows:

Location Test Date Test Parameters*

EPA 1 – Baghouse Stack 23 November 2017 Ammonia

* Flow rate, velocity, temperature and moisture were determined unless otherwise stated

The sampling methodologies chosen by Ektimo are those recommended by the NSW Office of Environment and Heritage (as specified in the Approved Methods for the Sampling and Analysis of Air Pollutants in New South Wales, January 2007).

All results are reported on a dry basis at STP. Unless otherwise indicated, the methods cited in this report have been performed without deviation.

Plant operating conditions have been noted in the report.

2 RESULTS SUMMARY

The following licence comparison table shows that all analytes highlighted in green are below the licence limit set by the NSW EPA as per licence 12593 (last amended on 5 July 2017).

EPA Parameter Units Licence limit Detected values Detected values

Test 1 Test 2

Ammonia and ammonium compounds mg/m3 2 0.67 1.8EPA 1 - Baghouse Stack

Page 5: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 5 of 8

3 RESULTS

3.1 EPA 1 - Baghouse Stack

Date Client

Report Stack ID

Licence No. Location

Ektimo Staff State

Process Conditions Please refer to client records.

space space space space space space space space

Sampling Plane Details

Sampling plane dimensions

Sampling plane area

Sampling port size, number

Access & height of ports Fixed ladder 10 m

Duct orientation & shape Vertical Circular

Downstream disturbance Exit >2 D

Upstream disturbance Bend >6 D

No. traverses & points sampled 2 12

Sample plane compliance to AS4323.1

space space space space space space space space

Stack Parameters

Moisture content, %v/v 1.7

Gas molecular weight, g/g mole 28.8 (wet) 29.0 (dry)

Gas density at STP, kg/m³ 1.29 (wet) 1.29 (dry)

Flow measurement time(s) (hhmm) 1054, 1230, 1410 & 1532

Temperature, °C 39

Velocity at sampling plane, m/s 8.3

Volumetric flow rate, discharge, m³/s 9.4

Volumetric flow rate (wet STP), m³/s 8.2

Volumetric flow rate (dry STP), m³/s 8.1

Mass flow rate (wet basis), kg/hour 38000

space space space space space space space space

Isokinetic Results

Sampling time

Mass Rate Mass Rate Mass Rate

mg/m³ g/min mg/m³ g/min mg/m³ g/min

Ammonia 1.2 0.6 0.67 0.33 1.8 0.88

Isokinetic Sampling Parameters

Sampling time, min 60 60

Isokinetic rate, % 103 102

Velocity difference, % -2 1

Gas Flow Parameters

Test 1

1103-1208

Average

Concentration Concentration

2" BSP (x2)

Ideal

23/11/2017

R004882

12593

1420-1525

Concentration

Test 2

Ingal Civil Products

EPA 1 - Baghouse Stack

Minto

NSWDavid Hill & Ryan Collins

1200 mm

1.13 m²

Page 6: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 6 of 8

4 PLANT OPERATING CONDITIONS

Unless otherwise stated, the plant operating conditions were normal at the time of testing. See Ingal Civil

Products’s records for complete process conditions.

5 TEST METHODS

All sampling and analysis was performed by Ektimo unless otherwise specified. Specific details of the

methods are available upon request.

1. Analysis performed by Envirolab, NATA accreditation number 2901. Results were reported to Ektimo on 5 December 2017 in report

number 180796.

6 QUALITY ASSURANCE/ QUALITY CONTROL INFORMATION

Ektimo are accredited by the National Association of Testing Authorities (NATA) for the sampling and analysis

of air pollutants from industrial sources. Unless otherwise stated test methods used are accredited with the

National Association of Testing Authorities. For full details, search for Ektimo at NATA’s website

www.nata.com.au.

Ektimo are accredited by NATA (National Association of Testing Authorities) to ISO/IEC 17025 - Testing.

ISO/IEC 17025 - Testing requires that a laboratory have adequate equipment to perform the testing, as well as

laboratory personnel with the competence to perform the testing. This quality assurance system is

administered and maintained by the Quality Director.

NATA is a member of APLAC (Asia Pacific Laboratory Accreditation Co-operation) and of ILAC (International

Laboratory Accreditation Co-operation). Through the mutual recognition arrangements with both of these

organisations, NATA accreditation is recognised world –wide.

A formal Quality Control program is in place at Ektimo to monitor analyses performed in the laboratory and

sampling conducted in the field. The program is designed to check where appropriate; the sampling

reproducibility, analytical method, accuracy, precision and the performance of the analyst. The Laboratory

Manager is responsible for the administration and maintenance of this program.

Sampling Method Analysis Method Uncertainty*

Sampling Analysis

NSW TM-1 NA - ✓ NA

NSW TM-22 NSW TM-22 8% ✓ ✓

NSW TM-2 NA 2% ✓ NA

NSW TM-2 NA 8% ✓ NA

NSW TM-2 NA 7% ✓ NA

USEPA CTM - 027 APHA 4500-NH3 not specified ✓ ✓1

Parameter NATA Accredited

Velocity

Temperature

Flow rate

Sample plane criteria

Moisture content

Ammonia

* Uncertainty values cited in this table are calculated at the 95% confidence level (coverage factor = 2)

Page 7: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 7 of 8

7 DEFINITIONS

The following symbols and abbreviations may be used in this test report:

~ Approximately < Less than > Greater than ≥ Greater than or equal to APHA American public health association, Standard Methods for the Examination of Water and

Waste Water AS Australian Standard BSP British standard pipe CARB Californian Air Resources Board CEM Continuous Emission Monitoring CEMS Continuous Emission Monitoring System CTM Conditional test method D Duct diameter or equivalent duct diameter for rectangular ducts D50 ‘Cut size’ of a cyclone defined as the particle diameter at which the cyclone achieves a 50%

collection efficiency ie. half of the particles are retained by the cyclone and half are not and pass through it to the next stage. The D50 method simplifies the capture efficiency distribution by assuming that a given cyclone stage captures all of the particles with a diameter equal to or greater than the D50 of that cyclone and less than the D50 of the preceding cyclone.

DECC Department of Environment & Climate Change (NSW) Disturbance A flow obstruction or instability in the direction of the flow which may impede accurate flow

determination. This includes centrifugal fans, axial fans, partially closed or closed dampers, louvres, bends, connections, junctions, direction changes or changes in pipe diameter.

DWER Department of Water and Environmental Regulation EPA Environment Protection Authority FTIR Fourier Transform Infra Red ISC Intersociety committee, Methods of Air Sampling and Analysis ISO International Organisation for Standardisation NA Not applicable NATA National Association of Testing Authorities NIOSH National Institute of Occupational Safety and Health NT Not tested or results not required OM Other approved method OU The number of odour units per unit of volume. The numerical value of the odour

concentration is equal to the number of dilutions to arrive at the odour threshold (50% panel response).

PM10 Atmospheric suspended particulate matter having an equivalent aerodynamic diameter of less than approximately 10 microns (µm).

PM2.5 Atmospheric suspended particulate matter having an equivalent aerodynamic diameter of less than approximately 2.5 microns (µm).

PSA Particle size analysis RATA Relative Accuracy Test Audit STP Standard temperature and pressure. Gas volumes and concentrations are expressed on a dry

basis at 0°C, at discharge oxygen concentration and an absolute pressure of 101.325 kPa, unless otherwise specified.

TM Test Method TOC The sum of all compounds of carbon which contain at least one carbon to carbon bond, plus

methane and its derivatives. USEPA United States Environmental Protection Agency VDI Verein Deutscher Ingenieure (Association of German Engineers) Vic EPA Victorian Environment Protection Authority VOC Any chemical compound based on carbon with a vapour pressure of at least 0.010 kPa at 25°C

or having a corresponding volatility under the particular conditions of use. These compounds may contain oxygen, nitrogen and other elements, but specifically excluded are carbon monoxide, carbon dioxide, carbonic acid, metallic carbides and carbonate salts.

XRD X-ray Diffractometry

Page 8: Emission Testing Report Ingal Civil Products, Minto Plant

Ektimo 11 January 2018

Report R004882 prepared for Ingal Civil Products, Minto Page 8 of 8

8 APPENDIX 1. ENVIROLAB AMMONIA REPORT

Page 9: Emission Testing Report Ingal Civil Products, Minto Plant

Envirolab Services Pty Ltd

ABN 37 112 535 645

12 Ashley St Chatswood NSW 2067

ph 02 9910 6200 fax 02 9910 6201

[email protected]

www.envirolab.com.au

CERTIFICATE OF ANALYSIS 180796

1/251 Princes Hwy, Unanderra, NSW, 2526Address

D HillAttention

Ektimo (Unanderra)Client

Client Details

08/11/2017Date completed instructions received

08/11/2017Date samples received

7 LiquidsNumber of Samples

R004882Your Reference

Sample Details

Results are reported on a dry weight basis for solids and on an as received basis for other matrices.

Samples were analysed as received from the client. Results relate specifically to the samples as received.

Please refer to the following pages for results, methodology summary and quality control data.

Analysis Details

Tests not covered by NATA are denoted with *Accredited for compliance with ISO/IEC 17025 - Testing.

NATA Accreditation Number 2901. This document shall not be reproduced except in full.

05/12/2017Date of Issue

05/12/2017Date results requested by

Report Details

David Springer, General Manager

Authorised By

Nick Sarlamis, Inorganics Supervisor

Results Approved By

Revision No: R00

180796Envirolab Reference: Page | 1 of 6

Page 10: Emission Testing Report Ingal Civil Products, Minto Plant

Client Reference: R004882

0.0180.050mg/LAmmonia as N in water

<1010µgAmmonia as N in impinger

240200mLVolume

29/11/201729/11/2017-Date analysed

29/11/201729/11/2017-Date prepared

LiquidLiquidType of sample

N5907N5906UNITSYour Reference

180796-7180796-6Our Reference

Miscellaneous Inorganics

9.91.90.0503.60.32mg/LAmmonia as N in water

1,700320<1073041µgAmmonia as N in impinger

170170140200130mLVolume

29/11/201729/11/201729/11/201729/11/201729/11/2017-Date analysed

29/11/201729/11/201729/11/201729/11/201729/11/2017-Date prepared

LiquidLiquidLiquidLiquidLiquidType of sample

N5905N5904N5903N5902N5901UNITSYour Reference

180796-5180796-4180796-3180796-2180796-1Our Reference

Miscellaneous Inorganics

Envirolab Reference: 180796

R00Revision No:

Page | 2 of 6

Page 11: Emission Testing Report Ingal Civil Products, Minto Plant

Client Reference: R004882

Ammonia in impingers/filter pads using Discrete Analyser. Inorg-093

Ammonia - determined colourimetrically, based on APHA latest edition 4500-NH3 F. Soils are analysed following a KCl extraction.

Inorg-057

Methodology SummaryMethod ID

Envirolab Reference: 180796

R00Revision No:

Page | 3 of 6

Page 12: Emission Testing Report Ingal Civil Products, Minto Plant

Client Reference: R004882

10710730.330.321<0.005Inorg-0570.005mg/LAmmonia as N in water

107107543411<10Inorg-09310µgAmmonia as N in impinger

29/11/201729/11/201729/11/201729/11/2017129/11/2017-Date analysed

29/11/201729/11/201729/11/201729/11/2017129/11/2017-Date prepared

180796-2LCS-W1RPDDup.Base#BlankMethodPQLUnitsTest Description

Spike Recovery %DuplicateQUALITY CONTROL: Miscellaneous Inorganics

Envirolab Reference: 180796

R00Revision No:

Page | 4 of 6

Page 13: Emission Testing Report Ingal Civil Products, Minto Plant

Client Reference: R004882

Not ReportedNR

National Environmental Protection MeasureNEPM

Not specifiedNS

Laboratory Control SampleLCS

Relative Percent DifferenceRPD

Greater than>

Less than<

Practical Quantitation LimitPQL

Insufficient sample for this testINS

Test not requiredNA

Not testedNT

Result Definitions

Australian Drinking Water Guidelines recommend that Thermotolerant Coliform, Faecal Enterococci, & E.Coli levels are less than1cfu/100mL. The recommended maximums are taken from "Australian Drinking Water Guidelines", published by NHMRC & ARMC2011.

Surrogates are known additions to each sample, blank, matrix spike and LCS in a batch, of compounds whichare similar to the analyte of interest, however are not expected to be found in real samples.

Surrogate Spike

This comprises either a standard reference material or a control matrix (such as a blank sand or water) fortifiedwith analytes representative of the analyte class. It is simply a check sample.

LCS (LaboratoryControl Sample)

A portion of the sample is spiked with a known concentration of target analyte. The purpose of the matrix spikeis to monitor the performance of the analytical method used and to determine whether matrix interferencesexist.

Matrix Spike

This is the complete duplicate analysis of a sample from the process batch. If possible, the sample selectedshould be one where the analyte concentration is easily measurable.

Duplicate

This is the component of the analytical signal which is not derived from the sample but from reagents,glassware etc, can be determined by processing solvents and reagents in exactly the same manner as forsamples.

Blank

Quality Control Definitions

Envirolab Reference: 180796

R00Revision No:

Page | 5 of 6

Page 14: Emission Testing Report Ingal Civil Products, Minto Plant

Client Reference: R004882

Measurement Uncertainty estimates are available for most tests upon request.

Where sampling dates are not provided, Envirolab are not in a position to comment on the validity of the analysis whererecommended technical holding times may have been breached.

When samples are received where certain analytes are outside of recommended technical holding times (THTs), the analysis hasproceeded. Where analytes are on the verge of breaching THTs, every effort will be made to analyse within the THT or as soon aspracticable.

In circumstances where no duplicate and/or sample spike has been reported at 1 in 10 and/or 1 in 20 samples respectively, thesample volume submitted was insufficient in order to satisfy laboratory QA/QC protocols.

Matrix Spikes, LCS and Surrogate recoveries: Generally 70-130% for inorganics/metals; 60-140% for organics (+/-50% surrogates)and 10-140% for labile SVOCs (including labile surrogates), ultra trace organics and speciated phenols is acceptable.

Duplicates: <5xPQL - any RPD is acceptable; >5xPQL - 0-50% RPD is acceptable.

For VOCs in water samples, three vials are required for duplicate or spike analysis.

Spikes for Physical and Aggregate Tests are not applicable.

Filters, swabs, wipes, tubes and badges will not have duplicate data as the whole sample is generally extracted during sampleextraction.

Duplicate sample and matrix spike recoveries may not be reported on smaller jobs, however, were analysed at a frequency to meetor exceed NEPM requirements. All samples are tested in batches of 20. The duplicate sample RPD and matrix spike recoveries forthe batch were within the laboratory acceptance criteria.

Laboratory Acceptance Criteria

Envirolab Reference: 180796

R00Revision No:

Page | 6 of 6