emerson flow product up-date. · emerson flow ‘unlimited’ precision flow data management &...
TRANSCRIPT
Emerson Flow Product
Up-date.
[File Name or Event] Emerson Confidential 27-Jun-01, Slide 2
FY15 Emerson Flow Europe Solving Problems – Delivering Value
Flow Technologies – Recommending the best “fit for purpose” technology,
leveraging field-proven best practices and utilizing inherent device data to gain early insight and enhance critical process units in your facility.
Flow Systems – Utilizing hardware integration, intelligent operations, turnkey
/ automation systems to enhance standardization and operational effectiveness and capital efficiency.
Flow Services – Applying maintenance, commissioning, consulting and asset
health services for long-term asset sustainability and assurance.
Emerson FLOW ‘Unlimited’
Precision
Flow
Data Management &
Control
Orifice
Fittings Ultrasonic Coriolis
Software RTU FC SCADA Systems Lifecycle care
Metrology service
Turbine
STRONGEST FLOW SOLUTIONS PORTFOLIO IN THE INDUSTRY
Optimize accuracy and reliability of the
complete measurement system VALUE:
Fluid
Characteristics
Gas composition
Gas sampler Pressure Temperature
Operating data
GC Viscosity Density
Vortex Mag meter
CMFS series
Scalable platform, compact,
lightweight, drainable
CMF350 to CMFHC4
High capacity platform (4-in to 12-in),
best two-phase performances
5700 transmitter
Enhanced meter health
diagnostics, 3mA outputs,
intuitive LOI
D&V new generation
Universal Features & Functionality,
innovative health diagnostics
ISO 17025 gas& liquid
calibration stands
@Slough
8800 Super Duplex
Higher corrosion
resistance
8700M platform
Stronger, smarter &
easier to use
IS output, SST housing
Differentiated
products &
services for
O&G
Product
Maximum
Flowrate
(kg/hr)
Maximum
Working
Pressure
% Liquid
Acc.
Flat Spec
Turndown
CMFS010 110 414 bar
0.1% 30:1
CMFS015 330
CMFS025 1770
250 bar CMFS050 5130
CMFS100 23,500
CMFS150 49,100
F050P 8160 345 bar 0.1% 20:1
F025P 2720 160 bar
D100S 10,896 340 bar 0.75%
10:1 D150S 38,136 330 bar 0.86%
D300S 190,680 214 bar 0.57%
F100P 10,000 431 bar 0.2%
10:1
HPC010 100 1034 bar
MMI Coriolis Meters deliver measurement confidence at extreme pressures
The Next Generation of Process Insight is here
Productivity Through Simplified Solutions
– Conserving time and energy
Repeatable, Reliable, Accurate Measurements
– Total Confidence
A Window Into Your Process
– Helping You Meet your Goals
SD Card Details
•The 5700 Transmitter contains a SD Card
•This card is the “personality of the meter”
•Contains a backup of:
•Transmitter Configurations
•Meter Verification Baseline, history
•Data log
•Other
•Also Contains “Feature Key” License
SD Card Details
•The new transmitter now has all the configuration,
features, history etc. of the old transmitter.
•If a transmitter needs to be replaced, the SD card can be
transferred to a new transmitter
Smart Meter Verification
•5700 will be available with SMV in all configurations
•Including 9-wire remote for the first time (9-wire cable distance
limited to 60 feet)
#1 Meter Health Verification tool is
available for all configurations
Checks the drive coil, pickoff coils, RTD, electronics, and tube stiffness
Values are stored as the meter’s Smart Meter Verification Signature
SMV delivers complete meter and transmitter functional assurance
A complete check of the flow meter’s health to ensure confidence
Event and Data Historian 5700 transmitter continuously stores process data in memory
– Provides proactive approach to troubleshooting and insight
into production
– Short Term Data Historian: 1-second data (30 Days)
– Long term Data Historian: 5-minute Min, Max, Ave, Std Dev
(25 years)
Full and Partial data file downloads to get exactly the
information needed
– Data is in non proprietary .CSV format, can be analyzed
through many common programs
Variables:
• Time
• Status
• Mass Flow
• Density
• Line Temp
• Case Temp
• Vol Flow
• Tube Freq
• Drive Gain
• LPO
(Filtered)
• RPO
(Filtered)
• Elec Temp
• Input Voltage
0.74
0.75
0.76
0.77
0.78
0.79
0.8
0.81
0
20
40
60
80
100
120
140
160
1
12
23
34
45
56
67
78
89
10
0
11
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
21
0
22
1
23
2
24
3
25
4
26
5
27
6
28
7
29
8
30
9
32
0
33
1
34
2
35
3
36
4
37
5
38
6
39
7
40
8
41
9
43
0
44
1
45
2
46
3
47
4
48
5
49
6
50
7
51
8
52
9
MassFlow kg/s Max
MassFlow kg/s Min
MassFlow kg/s Avg
DrvGain % Max
Density g/cc Avg
More Actionable Information
No more cryptic alert codes!
Succinct notification of the problem and cause, with recommended actions to resolve the issue
Two-Phase flow indication A new software feature aimed at bringing clear,
concise information to users about the condition of their fluid
Provides notification of fluid being in one of three regimes:
– Single Phase – Accurate and Repeatable measurement
– Moderate Entrainment – Meter may be outside Accuracy specification, but measurements are repeatable
– Severe entrainment – Measurement is likely neither accurate or repeatable
Notification available via display, digital registers, or can be mapped to an analog output
The Next Generation of Process Insight is here
Productivity Through Simplified Solutions
– Conserving time and energy
Repeatable, Reliable, Accurate Measurements
– Total Confidence
A Window Into Your Process
– Helping You Meet your Goals