emc test r - falcom · the deviations as specified in 2.4 were ascertained in the course of the...

25
EUROFINS PRODUCT SERVICE GMBH EMC TEST - REPORT TEST REPORT NUMBER: G0M20904-2307-E-13 Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888 0 Germany Fax +49-33631-888 660

Upload: duongcong

Post on 30-May-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

EUROFINS PRODUCT SERVICE GMBH

EMC TEST - REPORT

TEST REPORT NUMBER: G0M20904-2307-E-13

Eurofins Product Service GmbH Storkower Str. 38c, 15526 Reichenwalde, Phone +49-33631-888 0 Germany Fax +49-33631-888 660

Page 2: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 4

TABLE OF CONTENTS

1 General Information 2

1.1 Notes 2

1.2 Operator 2

1.3 Testing laboratory 3

1.3.1 Location 3

1.3.2 Details of accreditation status 3

1.3.3 Test location, if different 3

1.4 Details of applicant 4

1.5 Application details 4

1.6 Test item 4

1.6.1 Description of test item 4

1.6.2 Manufacturer (if different from approval holder in point 1.4) 4

1.7 Test standards 4

2 Technical test 5

2.1 Summary of test results 5

2.2 Test environment 5

2.3 Test equipment utilized 6

2.4 Testresults acc. EN 301 489 - 7 /14/ 7

2.4.1 Carried out emission tests 8

2.4.2 Carried out immunity tests 10

2.4.3 Test protocols 14

3 Normative references 19

Annex A: Pictures

Annex B: Diagrams

Page 3: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP
Page 4: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 6

1.3 Testing laboratory 1.3.1 Location EUROFINS PRODUCT SERVICE GMBH STORKOWER STR. 38c D-15526 REICHENWALDE B. BERLIN GERMANY Telephone : + 49 33631 888-0 Telefax : + 49 33631 888-660 1.3.2 Details of accreditation status DAR ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: DAT-P-268/08 RECOGNIZED NOTIFIED BODY EMC REGISTRATION NUMBER: BNetzA-bS EMV-07/61 RECOGNIZED NOTIFIED BODY R&TTE REGISTRATION NUMBER: BNetzA-bS-02/51-53 FCC FILED TEST LABORATORY REG.-NO. 96970 A2LA ACCREDITED TESTING LABORATORY CERTIFICATE NO. 1983.01 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY BLUETOOTH QUALIFICATION REVIEW BOARD INDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 1.3.3 Test location, if different Name : ./. Street : ./. Town : ./. Country : ./. Telephone : ./. Fax : ./. Email : ./.

Page 5: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 7

1.4 Details of applicant Name : Falcom Wireless Communications GmbH Street : Gewerbering 6 Town : 98704 Langewiesen Country : Germany Telephone : +49 3677 8042-0 Fax : +49 3677 8042-215 Email : [email protected] Contact : Herr Ralf Leipoldt Telephone : +49 3677 8042-0 1.5 Application details Date of receipt of application : 06.04.2009

Date of receipt of test item : 06.04.2009

Date of test : 28.04.2009 1.6 Test item 1.6.1 Description of test item Description of test item : GSM/GPRS/GPS tracking unit

Type identification : FOX-LT-IP

Serial number : without

Voltage supply : 12 / 24 VDC

Operating Mode : GSM-link 1.6.2 Manufacturer (if different from approval holder in point 1.4) Name : --- Street : --- Town : --- Country : --- 1.7 Test standards

EN 301 489-1 V 1.8.1 EN 301 489-7 V 1.3.1

EN 55022: 2006 + A1: 2007

Page 6: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 8

2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. or The deviations as specified in 2.4 were ascertained in the course of the tests performed. 2.2 Test environment Temperature : 24,5 ° C Relative humidity content : 31 % Air pressure : 1005 hPa

Page 7: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 6 of 9

2.3 Test equipment utilized

No. Test Equipmen Type Manufacturer ETS 0001 ESD Gun SESD 30000 Schlöder ETS 0008 Antenna Loop antenna Siemens ETS 0012 Biconical Antenna HK 116 R & S ETS 0013 LPD Antenna HL 223 R & S ETS 0014 Log Periodical Antenna HL 025 R & S ETS 0038 RF amplifier 150L Amplifier Research ETS 0032 Controller HD 050 Heinrich Deisel ETS 0039 Absorbing clamp MDS 21 R & S ETS 0040 Artificial Mains Network ESH3-Z5 R & S ETS 0041 T-Artificial Mains Network ESH3-Z4 R & S ETS 0042 Artificial Mains ESH3-Z6 R & S ETS 0045 Vehicle LISN NNBM 8126D Schwarzbeck ETS 0052 Audio analyzer UPA 4 R & S ETS 0056 Ultra Compact Simulator UCS 500 M4 EM Test ETS 0057 Motor Variac MV 2616 EM Test ETS 0058 Capacitive coupling clamp E 502 B Keytek/ EMC ETS 0059 Kikusui amplifier PCR 2000L Keytek/ EMC ETS 0064 CDN IEC 61000-4-6 Keytek/ EMC ETS 0066 EM Injection Clamp FCC/ EMC ETS 0076 Feeding bridge A SBA 1000 ESP ETS 0082 PC system Esotronic ETS 0085 Shielded room SR 1 Frankonia ETS 0086 Semi-Anechoic chamber AC 1 Frankonia ETS 0088 Color TV pattern Generator PM 5518-TX VPS Philips ETS 0092 Power Amplifier 150W1000 AR Amplifier Research ETS 0102 CDN M3-801/6 MEB ETS 0103 Magnetic field test set MF1000 EMC-Partner ETS 0148 RF Current Probe F-65 FCC ETS 0155 Signal Generator SMG R & S ETS 0157 TV and Sat-Signalgenerator VTG 700 Grundig ETS 0161 Harmonic / Flicker Analyzer HFA 3000 Schlöder ETS 0178 Open area test side 10m ETS ETS 0233 Direction coupler RK 100 MEB ETS 0276 Audio Analyzer UPL 16 R & S ETS 0282 RF bridge 75 Ohm 86207 A HP ETS 0287 EMI Test receiver ESHS10 R & S ETS 0288 Artificial mains ESH2-Z5 R & S ETS 0292 RF Generator SMHU R & S ETS 0348 RF Millivolt meter URV 55 R & S ETS 0300 RF amplifier 75 A 250 Ar ETS 0348 RF Millivolt meter URV 55 R & S ETS 0401 MPEG2 Generator DVG R & S ETS 0402 TV Messender SFQ R & S ETS 0409 Stripline DC220 Schwarzbeck ETS 0428 4-WIRE ISN with B1 ENY41 R & S ETS 0448 RF Power Amplifier AR 60S1G3 AR Amplifier Research ETS 0472 Antenna BTA-H Frankonia ETS 0474 EMI Test Receiver ESCS 30 R&S ETS 0485 Radio Communication Tester CMU 200 R&S

Page 8: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 7 of 10

2.4 Testresults acc. EN 301 489 - 7 /14/ 1st test test after modification production test

Test Emission / Immunity Done Test

passed Test failed

EN 301 489-1 /1/ clause 8.3, 8.4, 8.7 Conducted Emission EN 55022 /13/

EN 301 489-1 /1/ clause 8.2 Radiated Emission EN 55022 /13/

EN 301 489-1 /1/ clause 9.3 Electrostatic Discharge EN 61000-4-2 /2/

EN 301 489-1 /1/ clause 9.2 Radiated Immunity EN 61000-4-3 /3/

EN 301 489-1 /1/ clause 9.4 Electrical Fast Transients EN 61000-4-4 /4/

EN 301 489-1 /1/ clause 9.8

Transients comm.& diff. mode EN 61000-4-5 /5/

EN 301 489-1 /1/ clause 9.5 RF continues conducted EN 61000-4-6 /6/

EN 301 489-1 /1/ clause 9.7 Voltage dips and Interruption EN 61000-4-11 /8/

EN 301 489-1 /1/ clause 9.6

Transient and surges in vehiculars

ISO 7637-1 /11/ ISO 7637-2 /12/

Comment:

Page 9: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 8 of 11

2.4.1 Carried out emission tests 2.4.1.1 Conducted Emission This test is in accordance to subclause 8.3; 8.4 and 8.7 of EN 301 489-1 /1/. Test Equipment

• ETS 0040 • ETS 0085 • ETS 0474 • Software: ES-K1, Vers. 1.6SP2

Test Procedures • Test configuration The test configuration is contained inside of a shielded chamber and corresponds to the standard EN 55022 /13/. The equipment under test is placed in the facility on a wooden table 0.8 m high. The equipment under test is connected with the artificial mains network (AMN) in a distance of 0,8 m and also 0,8 m from other subassembly and metallic area. The observation of the equipment under test is realized by 3 video cameras and by a microphone. • Test parameters and marginal conditions The test are carried out with a nominal impedance by 50 Ω / 50 μH of the AMN in a frequency range of 150 kHz to 30 MHz. Further information please find in test report. The equipment under test fulfils the requirement in accordance with the criteria of the standard.

Page 10: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 9 of 12

80 cmto thegroundtable

80 cm

10 cm

40 cmmin

Conducted Emission according toEN 55022

EUT

AMNAMN

ISN

AE

Non-conductive table

Bonded to horizontal ground planeBonded to horizontal ground

plane

Rear of EUT to flushed with rear of taple top

AMN = Artificial mains networkAE = Associated equipmentEUT = Equipment under testISN = Impedance stabiliyation network

Page 11: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 10 of 13

2.4.2 Carried out immunity tests 2.4.2.1 RF Electromagnetic Field This test is in accordance to subclause 9.2 of EN 301 489-1 /1/. Test Equipment

• ETS 0086 • ETS 0155 • ETS 0448 • ETS 0472 • Software: ETS RF-Field v.27.09.2005

Test Procedures • Test configuration The test configuration is contained inside of a shielded chamber and corresponds to the standard EN 61000-4-3 /3/. The equipment under test is placed in the facility on a wooden table 0.8 m high on the centre axis of the chamber. The power supply and the RF connection points are close to the equipment under test at the floor of the chamber inside a connection box. The cables to this connection box are shielded and below the double floor. The transmitting antenna is placed in a height of 1.5m, in a distance of 3.0 m. The RF-generators are placed in a special room adjacent to the chamber. The observation of the equipment under test is realized by 3 video cameras and by a microphone. • Test parameters and marginal conditions The tests are carried out with a field strength by 3 V/m (measured in the unmodulated field) with amplitude modulated signal by a depth of 80 % by a sinusoidal audio signal of 1 kHz. The logarithmic step was 1% and the dwell time was 1s dependent of the EUT cycle time. Further information please find in test protocol. The equipment under test fulfils the requirement in accordance with the criteria of the standard.

Page 12: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 11 of 14

RF - Field according to EN 61000 - 4 - 3

Field-generating antenna

Lines > 3 mor not definedIrradiated length has to be 1 m

0,8 m

Absorber elements placed as required in partly covered anechoice chambers to reduce the ground reflexion

Absorber or disturbance filter

Uniform area

Non-conductive table

Lines < 3 mon 1 m total length, low-induction bunched

Real cabling < 1 m

Page 13: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 12 of 15

2.4.2.2 Transients and Surges in vehicular enviroment These test are applicable to mobile radio and ancillary equipment intended for use in a vehicular enviroment. This test is in accordance to subclause 9.6 of EN 301 489- 1 /1/. Test equipment

• ETS 0244 • ETS 0245 • ETS 0246 • Software: ISMISO 4.11

Test Procedures • Test configuration The test configuration is in correspondence to the standard ISO 7637 - 1 / - 2 /11/, /12/. The test is carried out on a wooden table with a grounded metal plate on its top. The equipment under test is placed on an insulating support of 100 mm height above this metal plate. • Test parameters and marginal conditions The tests are carried out are the pulses according to subclause 9.6.2.1 and 9.6.2.2 of EN 301 489- 1 /1/ and the special requiremnets of EN 301 489-7 /2/ subclause 7.2.2. The overview please find in the test protocol.

Page 14: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 13 of 16

Transients and Surges in vehicular enviroment

ISO 7637

Pulse injection (prinzipe schemata)

Page 15: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 14 of 17

2.4.3 Test protocols

Conducted emission 15

RF-Field 16

RF-common mode 17

Transients and Surges in vehicular environment 18

Page 16: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 15 of 17

Conducted Emission

Emission

Standard : EN 301 489-1 /1/ (EN 55022 /13/)

Reg. no. : G0M20904-2307-E-13

Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP

Date : 29.04.2009

Class : B

Frequency range Network Passed Failed Number of rechecks

150 kHz - 30 MHz R S 0

Operating Mode: GSM-link Instrumentation uncertainty: Ulab(cond) = 3.8 dB Comment: See attached diagrams.

Page 17: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 16 of 17

Radiofrequency Electromagnetic Field Immunity

RF Field

Standard : EN 301 489-1 /1/ subclause 9.2 (EN 61000-4-3 /3/)

Reg. no. : G0M20904-2307-E-13

Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP

Date : 29.04.2009

Test equipment : Anechoic chamber, amplifier: ar, antenna (BTA-H)

Frequency Range Voltage (RMS) Modulation Frequency Opinion

80 - 1000 MHz 3 V/m 1 kHz (80 % AM) A

1400 - 2700 MHz 3 V/m 1 kHz (80 % AM) A

Operating Mode: GSM-link Opinion: A : No loss of performance or function.

B : Temporary loss of function or performance which is self-recoverable.

C : Temporary loss of function or perform, which req. operat. intervention or system reset.

D : Loss of function which is not recoverable. Passed: yes / no

Page 18: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 17 of 17

Conducted Immunity

RF - common mode

Standard : EN 301 489-1 /1/ subclause 9.5 (EN 61000-4-6 /6/)

Reg. no. : G0M20904-2307-E-13

Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP

Date : 29.04.2009

Test port Voltage (rms)

Modulation Frequency Frequency Range Opinion

12 VDC 3 1 kHz 150 kHz - 80 MHz A

24 VDC 3 1 kHz 150 kHz - 80 MHz A

Operating Mode: GSM-link Opinion: A : No loss of performance or function.

B : Temporary loss of function or performance which is self-recoverable.

C : Temporary loss of function or perform, which req. operat. intervention or system reset.

D : Loss of function which is not recoverable.

Passed: yes / no

Page 19: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 18 of 18

Transients and surges in vehicular environment

Standard : EN 301 489-1 /1/ subclause 9.6 (ISO 7637-1 /-2 /11/, /12/)

Reg. no. : G0M20904-2307-E-13

Model no. : GSM/GPRS/GPS TRACKING UNIT / FOX-LT-IP

Date : 29.04.2009

Testport Pulse Level ISO 7637-2 Test requirements Criteria

DC-Power line (12V) 1 III 10 times C

DC-Power line (12V) 2a III 10 times A

DC-Power line (12V) 2b III 10 times C

DC-Power line (12V) 3a III 20 minutes A

DC-Power line (12V ) 3b III 20 minutes A

DC-Power line (12V ) 4 III 10 times C

Testport Pulse Level ISO 7637-2 Test requirements Criteria

DC-Power line (24V) 1 III 10 times C

DC-Power line (24V) 2a III 10 times A

DC-Power line (24V) 2b III 10 times C

DC-Power line (24V) 3a III 20 minutes A

DC-Power line (24V ) 3b III 20 minutes A

DC-Power line (24V ) 4 III 10 times C

Opinion: A : No loss of performance or function.

B : Temporary loss of function or performance which is self-recoverable.

C : Temporary loss of function or perform. which req. operat. intervention or system reset.

D : Loss of function which is not recoverable. Passed: yes / no

Page 20: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 19 of 19

3 Normative references /1/ EN 301 489-1 V1.8.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements /2/ EN 61000-4-2 : 1995 + A1 : 1998 + A2 : 2001 „Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 2:

Electrostatic discharge immunity test. Basic EMC publication“. /3/ EN 61000-4-3 : 2006 + A1: 2008 „Electromagnetic Compatibility - Basic immunity standard - Radiated, radio-frequency

electromagnetic field. Immunity test“. /4/ EN 61000-4-4 : 2004 „Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 4:

Electrical fast transient/burst immunity test. Basic EMC publication“. /5/ EN 61000-4-5 : 2007 „Electromagnetic Compatibility - Basic immunity standard. Surge immunity Test“. /6/ EN 61000-4-6 : 2007 „Electromagnetic Compatibility - Basic immunity standard - Conducted disturbances induced by

radio-frequency fields. Immunity test. /7/ EN 61000-4-8: 1993 + A1: 2001 „Electromagnetic Compatibility - Testing and measurements techniques Power frequency magnetic field immunity test”. /8/ EN 61000-4-11: 2004

„Electromagnetic Compatibility (EMC); Part 4: Testing and measurements techniques - Section 11: Voltage dips, short interruptions and voltage variations immunity tests - Basic EMC publication“.

/11/ ISO 7637-1 : 2002 „Road vehicles - Electrical disturbance by conducting and coupling Part 1: Definitions and general /12/ ISO 7637-2 : 2004 + A1: 2008 „Road vehicles - Electrical disturbance by conducting and coupling Part 2: Vehicles with nominal 12V or 24V supply voltage – Electrical transient conduction along supply lines only /13/ EN 55022 : 2006 + A1: 2007 „Limits and methods of measurement of radio interference characteristics of information technology

equipment“. /14/ EN 301 489-7 : V1.3.1 Specific conditions for mobile and portable radio and ancillary equipment of digital cellular

radio telecommunications systems (GSM and DCS)

Page 21: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

Test Report No.: G0M20904-2307-E-13 Eurofins Product Service GmbH

Storkower Str. 38c, D-15526 Reichenwalde, Germany Annex A Page 1 of 1

Annex A: Pictures

Page 22: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

EMI voltage test in the dc-mains according to EN 55022

ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 13.5 VDCTest Specification: V-Network: ESH3-Z5 (L)Comment 1: mode: GSM1900 linkComment 2: mode:

-20

-10

0

10

20

30

40

50

60

70

Level [dBµV]

150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]

MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit

Page 1/1 28.04.2009 09:36 EN 55022 Vdc

Annex B Page 1/4

Page 23: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

EMI voltage test in the dc-mains according to EN 55022

ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 13.5 VDCTest Specification: V-Network: ESH3-Z5 (N)Comment 1: mode: GSM1900 linkComment 2: mode:

-20

-10

0

10

20

30

40

50

60

70

Level [dBµV]

150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]

MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit

Page 1/1 28.04.2009 09:24 EN 55022 Vdc

Annex B Page 2/4

Page 24: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

EMI voltage test in the dc-mains according to EN 55022

ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 27 VDCTest Specification: V-Network: ESH3-Z5 (L)Comment 1: mode: GSM1900 linkComment 2: mode:

-20

-10

0

10

20

30

40

50

60

70

Level [dBµV]

150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]

MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit

Page 1/1 28.04.2009 10:00 EN 55022 Vdc

Annex B Page 3/4

Page 25: EMC TEST R - Falcom · The deviations as specified in 2.4 were ascertained in the course of the tests ... ETS 0014 Log Periodical Antenna ... ETS 0076 Feeding bridge A SBA 1000 ESP

EMI voltage test in the dc-mains according to EN 55022

ORDER NO: G0M20904-2307Approval Holder: Falcom Wireless Communication GmbHEUT: GSM/GPRS/GPS-tracking unitModel: FOX-LT-IPTest Site / Operator: Eurofins Product Service GmbH / Mr. KleinTest Conditions: Tnom: 23°C, Unom: 27 VDCTest Specification: V-Network: ESH3-Z5 (N)Comment 1: mode: GSM1900 linkComment 2: mode:

-20

-10

0

10

20

30

40

50

60

70

Level [dBµV]

150k 300k 500k 700k 1M 2M 3M 4M 6M 10M 30MFrequency [Hz]

MES EN 55022 Vdc_pre PK MES EN 55022 Vdc_pre AV LIM EN 55022 V QP Voltage QP LimitLIM EN 55022 V AV Voltage AV Limit

Page 1/1 28.04.2009 09:49 EN 55022 Vdc

Annex B Page 4/4