EMBEDDABLE REFERENCE ELECTRODEFOR CONCRETE APPLICATIONS
Application
Silvion silver/silver chloride reference electrodes have, since 1985, been recognised by many as the highest quality silver chloride electrodes available. Constructed using advanced techniques which result in a porous silver matrix around a wire skeleton they provide a significantly higher electrode surface area than traditional electrodes constructed of silver wire which enhances both life and stability.
Silvion embeddable reference electrodes are designed specifically for installing in high alkaline and possibly chloride contaminated reinforced concrete structures. A predetermined chloride ion concentration is maintained in an inert electrolyte compatible with the silver/silver chloride element. Ionic continuity to the environment is ensured via a micro-porous sintered disc.
Availability
Three basic models of electrode are available depending upon the life required.
General Characteristics
Ref: CTS-MDS-03-01-Rev0
Stee
l in
Con
cret
e
[email protected] www.ctsonline.com Azerbaijan l Bahrain l Georgia l India l Kingdom of Saudi Arabia l Qatar l United Arab Emirates l United Kingdom l Malaysia
Electrolyte
20 mA
± 1mV (24 hours) @ 5µA load
-5mV ± 5mV
-0.65mV/ º C
-5 to+70º C
ACETAL
99.90% pure
1x2.5 mm2 multistrand (other cable typesavailable on request)
Inert Electrolyte with 0.5M KCl
Short Circuit Current (<1 min)
Stability (Potential drift at constanttemperature and environment)
Accuracy (Vs SCE in 3% NaCl@20º C)
Temperature Coefficient
Temperature Range
Casing Material
Silver Base Material
Standard Cable
Quality Assurance
All Silvion reference electrodes are fully tested, calibrated and supplied complete with a calibration certificate. They are individually identified with a unique number to ensure full traceability. All dimensions ±1 mm unless otherwise stated.
Ref: CTS-MDS-03-01-Rev0
Stee
l in
Con
cret
e
Overall
Length (mm)
Diameter (mm)
Sintered disc diameter (mm)
Silver Chloride Element
Length (mm)
Diameter (mm)
Geometric surface area (cm2)
Real aurface area (cm2)
Design Life (years) @ 0.1µA load
WE10
60
18
15
15 ± 2
5x5
10
500
3
WE50
80
20
15
20 ± 2
6
4
200
25
WE100
110
22
20
50 ± 2
5x5
10
500
30
Performance Data
Disclaimer
The information provided in this document was accurate at the time it was published, however, we reserve the right to revise this document without prior warning.
[email protected] www.ctsonline.com Azerbaijan l Bahrain l Georgia l India l Kingdom of Saudi Arabia l Qatar l United Arab Emirates l United Kingdom l Malaysia