elevator control r1 · configure number of floors being controlled in system options enable the isc...
TRANSCRIPT
![Page 1: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/1.jpg)
1Training Services
B.A.S.I.S. Elevator Control
Quick Reference Guide
![Page 2: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/2.jpg)
2Training Services
Configuration Checklist
Configure number of floors being controlled in System Options
Enable the ISC for Elevator Support
Enable the card reader for Elevator and Track Floors (optional) on the readers tab
Configure the necessary BAS-1200 outputs on the elevator hardware tab of the reader
Optional: Configure the necessary BAS-1100 inputs on the elevator hardware tab of the reader
Configure the desired elevator access levels
Assign elevator access levels to cardholders
![Page 3: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/3.jpg)
3Training Services
System Options
• Select hardware options tab
• Modify number of elevator floors if needed
![Page 4: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/4.jpg)
4Training Services
• Modify Floors
• 128 Floors available
![Page 5: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/5.jpg)
5Training Services
ISC Configuration
• Select access panel
• Options tab
• Elevator support option
![Page 6: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/6.jpg)
6Training Services
Reader Setup
Add elevator reader
• Select elevator option
• Track floors requires BAS-1100 boards
![Page 7: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/7.jpg)
7Training Services
Add Elevator Hardware
• Elevator hardware tab
• Add BAS-1200 board(s)
• Floors will be added in blocks of 16
Elevator Hardware
![Page 8: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/8.jpg)
8Training Services
![Page 9: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/9.jpg)
9Training Services
Configure Access Levels
• Elevator Control Tab
• Access Levels for ElevatorsConsist of Floors and Times
Access Levels
![Page 10: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/10.jpg)
10Training Services
Configure Floor Outputs
• Assign each output relay to a specific floor
• Each floor may have different access times if required
• If the same time for each floor is used, select “Use one time..”
Floor Outputs
![Page 11: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/11.jpg)
11Training Services
• Daymode setting hasno effect on Stanleyreaders
• Facility code has noeffect on Stanleyreaders
Option Settings
![Page 12: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/12.jpg)
12Training Services
Floors are added individually
![Page 13: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/13.jpg)
13Training Services
![Page 14: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/14.jpg)
14Training Services
![Page 15: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/15.jpg)
15Training Services
Add Access Level
• Add access level that contains elevator control level
• Select elevator reader
• Select time zone
Access Level
![Page 16: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/16.jpg)
16Training Services
![Page 17: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/17.jpg)
17Training Services
Access level may now be assigned to cardholders
![Page 18: Elevator Control R1 · Configure number of floors being controlled in System Options Enable the ISC for Elevator Support Enable the card reader for Elevator and Track Floors (optional)](https://reader035.vdocuments.us/reader035/viewer/2022063018/5fdc851c17b10821ea131086/html5/thumbnails/18.jpg)
18Training Services
Online Facility Code:Valid facility code(s)will be allowed accessto controlled floorsduring valid time zones
• Hardware must be online with the ISC
Additional Features