Page 1: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erINDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS

10KVA ~ 3.2KVA (3/3)

Ultimate PowerProtection for MissionCrit ical & I.T Grade UPS

ELEKTRA SERIES

Page 2: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erDeutsche Power Elektra LF Series UPS is the world’s mostadvance true On-Line Uninterruptable Power System. ElektraLF series adopts Digital Signal Processor (DSP) technology,comprises of high current & high voltage Intelligent PowerModule, High Speed IGBT drive IC and professional drivecircuit, so it provides 100% Pure Sine Wave output, and itguarantees full safety of your highly sophisticated equipments.This series totally isolates its connected load from everypower problem that arises from the mains supply. It ensures100% protection to the load from the full range of powerdisturbances including harmonics, common-mode noise andfault conditions on the input bus and vice versa.

E l e k t ra I n d u st r i a l D es i g n S e r i esComprises of output power factor 0.9

Elektra LF Series (3/3) 10KVA~3.2MVA

T h r e e P h a s e I n & T h r e e P h a s e O u t( 1 0 K V A ~ 8 0 0 K V A )

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 3: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erDP

Ele

ctro

nics

e.K

(Deu

tsch

e Po

wer

Co.

, Lim

ited)

1 + 1 / N + X

INPUT

FILTER RECTIFIER INVERTERTRANSFORMER

STATICSWITCH

FILTER

OUTPUT

BATTERY

The range of capacity for 3/3 is from 10KVA to 800KVA (StandAlone). It supports redundant parallel connected up to 8 sets.Each set of UPS wi l l share load automatically.Elektra series delivers an excellent integrated autonomy,reduced footprint, optimum input, output performances andguarantees reliable power by adapting its performances tomeet individual load requirements.

This UPS ensures full load protection by combining softwaresolutions, parallel redundancy, safety and disconnectingdevices, system bypass switches, and communicationsolutions, to deliver reliable high-quality AC power.Elektra Series due to its industrial grade nature is flexibleenough to meet any power, redundancy, harmonic controland battery backup time requirements and is fully compatiblewith real-time remote monitoring and diagnostic tools.

Controlled circuit of auxiliary power for each provide reliable,stable power protection so that ensure all the control circuit towork properly. To ensure the normal operation of UPS systemsplay a key role. Elektra Series UPS's auxiliary power adopt 1+1redundancy design, when one of the auxiliary power failure, canbe continued by another auxiliary power supply. UPS continueto operate normally, while the LCD screen displays this warningmessage. When N + X sets of UPS (up to 8 sets) are working inredundant parallel or capacity-expanded parallel working modes,each set of UPS will automatically share the load. If one set ofUPS does not work due to malfunction, the UPS will automaticallyexit from operation, and the other sets of UPS will share the load.If the system is overloaded, all the UPS system will turn to bypassoperation. Parallel working can be classified into many workingmodes such as normal working mode, battery working mode,bypass power supply mode, maintenance working mode,combined power supply mode, and so on.

N+X Redundant Design

Parallel ConnectivityParallel Connectivity is available up to 8 Units, which further improvethe reliability and compatibility of the UPS. This system ensuresmore sensitive and reliable operations of the UPS to continuefeeding the load through parallel connectivity even if one unit isout of order the other unit still operate and ensures a continoussupply with out any interruption.

Elektra series UPS replaces traditionally insert electric circuitprocessing with high precession SMD technology. Thisinnovation not only save the space but also drasticallyeliminate the distortion of insert components in traditionalUPS circuit. What’s more, it ensures the integrate circuit asafe operation and enhances its reliability & operationprecision.Elektra series UPS, widely using SMD technology, is heat-resistant, highly accurate and also has an excellent filter,which greatly improves the whole performance of the UPS.It is more durable and its lifetime is prolonged by 80%.

High Precision SMD Technology

An important consideration has been given to allow generousaccess to the units electronic cards and power components.All the boards are accessible by the front panel for easilymaintenance and replacement.

Front access Maintenance

Elektra Series is equipped with Class-C lightning-proof systemserves as a protection measurement for the alternative powerinput into the computer room to prevent external lightningstrike or electrical surge voltage from entering the computerroom and from any damage to the equipment installed therein.This accessory system should be selected if no Class-C or belowlightning proof system is set up in the low voltage powerdistribution system output terminals, the computer room isfar from low voltage power distribution output or it is thespecial area liable to lightning strikes. Class-C lightning-proofsystem is designed for a max 20 KA for current flow and 8/20µsfor impulse current wave form.

Class-C Lightning-Proof System

Elektra Series adopts DSP, MCU and DDC real time processingall digital vector Control technology which increases powercomponent performance and enable active conditioning ofthe load. Due to this technology UPS can bear unbalanceload and can distribute perfectly in parallel mode

Leading Technology

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 4: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

er

Batteries are connected with UPS by an external battery switch,the battery switch is a ''three-stage'' DC switch that can bemanually closed, and has a control circuit controlled by the UPSelectronic tripping device. Effectively reducing the past due tobattery leakage or short circuit caused the fire risk for the safeoperation of the UPS has provided a guarantee.

UPS is equipped with a emergency stop button, this emergencystop button can be used remotely to shutdown the UPS.

Unique Battery Protection Function & Management

Elektra series is equipped with Touch Screen LCD allowingenhanced features to be store and display with easy to view,the details of viewing features on the LCD are as follows:-

UPS Information-Rectifier Information-Inverter Information-Battery Information-Logging History-Alarms Information-Load Information

LCD Display

Industrial Machines, Large mainframe oriented data centers,Computer rooms; Small mainframe Mini computers, Centralizedor clustered servers, Tele communications applications, Medicalanalysis equipment such as MRI and CAT scanners, Laboratoryinstrumentation, Mission critical customized applications

Applications

For many years we have measured IT equipment loads withpower factors in the range 0.6 to 0.9 lagging. As a consequencewe have designed products with practical ratings in mind andwe have standardized on 0.9 power factor (pf) lag as a meansof determining nominal KVA/KW ratings. This rating conventionhas been adopted almost universally across the industry and so,for example, we have 90 KVA/80 KW as a standard frame rating.

Power Factor 0.9

The Elektra Series has an advance Battery managment functionincluding Battery malfunction test, prediction of backup timeafter battery discherge, Battery self test etc.

Elektra uses intelligent double conversion technology. Thisarchitecture combines the secure power provided bytraditional double conversion with the efficiency provided bydigital interactive technology. Up to eight Elektra units maybe connected in parallel, allowing you to customize and adaptour solution to yours changing load requirements.Elektra is available in the following configurations:Distributed Parallel; increasing power of the supply systemwhilst controlling costs, Centralized Parallel; using an additionalcommon output cubicle and providing a standby reserve linefor the whole system HFC (High Fault Clearance) Parallel;enabling simultaneous switching on of all available standbyreserve lines, with a downstream fault clearing capacity thatis four times higher.

Reliability

Safety: EN62040-1-1Conducted Emission: EN50091-2Radiated Emission: EN50091-2 - EMSEN61000-4-2(ESD)..... Level4EN61000-4-3 (RS)……………....................................................Level4EN61000-4-(EFT)…...............................................................Level4EN61000-4-5(Lightning surge)..............................................Level4EN61000-2-2 (Immunity to low Frequency signal)

Standard

DP E

lect

roni

cs e

.K (D

euts

che

Pow

er C

o., L

imite

d)

Set the maximum output power of the generator when asmaller one than needed is employed to extend the batteryduration time. in this case, the load is supplied by both thegenerator battery.

Generator Mode

LBS synchronizationSynchronize the output of the two independent UPS system(singal unit or parallel) even when the two systems areoperating on different modes (bypass / inverter) or on battery.

Multi-protectionSelf-diagnosis function will take placce before start-up forsafty.

Multi-protection: AC input under/over voltage, overload,short-circuit, over-current, over bus voltage, over temprature,fan failure, auxliary power failure, battery under voltage,battery over-charge and so on.

Optional FeaturesSpecial fetures available on demand. Harmonic filter, SNMPadopter, LBS cables, Battery temperature sensor, Bypasscurrent-sharing inductor.

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 5: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erDP

Ele

ctro

nics

e.K

(Deu

tsch

e Po

wer

Co.

, Lim

ited)

SNMP Card | Parallel Card | Dry Contact Card | C-Class LightingProtection | Battery Temperature Transmitter | JBUS /MODBUS Interface Cards | Telecommunication Port | RS232/ RS485 Environmental Card | GPRS Card | Standard ShutdownSoftware

Using user-friendly control panel modular in-line graphicdesign, to ensure reliable connection between the plug plates,the connection is configured with a connector lockingmechanical "locking" device. Users simply open the cabinetdoor that can be observed a glance at the control panel ofthe UPS "self-diagnosis".

Easy Maintenance of Structure Design

Front wiring terminationfor easy access

Front termination ofbreakersfor easy access

Communication

SNMP

SNMPTRAP

EntornatNetwork

WEBPAGE

SHUTDOWN

Server 2

Server 1

WindowsWorkstation

AdministratingWorkstation

RS232Terminal

RS232Link

AS400

MODBUS

EnvironmentalSensor

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 6: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erDP

Ele

ctro

nics

e.K

(Deu

tsch

e Po

wer

Co.

, Lim

ited)

MODEL

RANGE

INPUT

BYPASS OUTPUT

AC OUTPUT

Principal of workingPhaseVoltagePower FactorFrequencySoft Start

PhaseVoltageFrequencyTransfer Time

DC VoltageFloat Chg. Voltage.End VoltageMax. Dischg. CurrentChg. Current

PhaseVoltageFrequencyPower FactorWave FormTHDDynamic Respond rangeDynamic Respond timeVoltage. UndulationOver LoadWorking efficiencyCommunicationTemperatureHumidityNoiseDimension (L x W x H)Weight (Kg)

ES1033 E S 8 0 3 3E S 6 0 3 3E S 4 0 3 3E S 3 0 3 3E S 2 0 3 3E S 1 5 3 3

1 0 K VA /9 K W 8 0 K V A /7 2 K W6 0 K V A / 5 4 K W4 0 K VA / /3 6 K W3 0 K VA /2 7 K W2 0 K V A / 1 8 K W15KVA/13.5KW

True On-l ine, Double Conversion, Static Bypass Switch, Output with transformerThree phase + N + G380/400/415V±20%

50/60Hz±10%0-100% 5 Secs

Three Phase + N + G380/400/415V+20-40% (Adjustable)

±10% (Adjustable)0ms (When Overload)

10-25A (Adjustable)

Three Phase + N + G380/400/415V±1% (Balance load)

50/60Hz±0.05% (Battery)0.9 LaggingSine wave

Linear load<3%, Non-l inear load<5%±5% (From 0 to 100%)

<10ms (±5%)<±3% (Unbalance Load) <±1% (Balance Load)110% /60mins; 125% /10mins; >150% /1mins

>91%, 95%, ECORS232/RS485, SNMP (Optional) Dry Contact

0-50°C0-90%

50dB 60dB 63dB 65dB 68dB

DC SYSTEM

>0.98 (with f i l ter)

384V (12V X 32 Cells)432 V336V

396V (12V X 33 Cells)446V347V

25 13310271554033

8 0 0 x 5 7 0 x 1 1 9 5 m m 7 6 0 x 8 8 0 x 1 6 0 0217 525483330316273273

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics e.K(Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 7: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erDP

Ele

ctro

nics

e.K

(Deu

tsch

e Po

wer

Co.

, Lim

ited)

MODEL

RANGE

INPUT

BYPASS OUTPUT

AC OUTPUT

Principal of workingPhaseVoltagePower FactorFrequencySoft Start

PhaseVoltageFrequencyTransfer Time

DC VoltageFloat Chg. Voltage.End VoltageBattery TypeChg. Current

PhaseVoltageMax. Output currentFrequencyPower FactorWave FormTHDDynamic Respond rangeDynamic Respond timeVoltage. UndulationOver LoadWorking efficiencyCommunicationTemperatureHumidityNoiseDimension (L x W x H)Weight (Kg)

ES10033 ES50033ES40033ES30033ES20033ES16033ES12033

100KV/90KW 500KV/450KW400KV/360KW300KV//270KW200KV/180KW160KV/144KW120KV/108KW

True On-line, Double Conversion, Static Bypass Switch, Output with transformerThree phase + N + G380/400/415V±20%

50/60Hz±10%0-100% 5 Secs

Three Phase + N + G380/400/415V+20-40% (Adjustable)

±10% (Adjustable)0ms (When Overload)

10-25A (Adjustable)

Three Phase + N + G380/400/415V±1% (Balance load)

50/60Hz±0.05% (Battery)0.9 LaggingSine wave

Linear load<2%, Non-linear load<5%±5% (From 0 to 100%)

<10ms (±5%)<±3% (Unbalance Load) <±1% (Balance Load)110% /60mins; 125% /10mins; >150% /1mins

>91%, 96%, ECORS232/RS485, SNMP (Optional) Dry Contact

0-50°C0-95%

65db

DC SYSTEM

>0.98 (with f i l ter)

3 8 4 V ( 1 2 V X 3 2 C e l l s )4 3 2 V3 3 6 V

4 8 0 V ( 1 2 V X 4 0 C e l l s )5 6 4 V4 1 2 V

Seald Led Acid Mentenance Free/ Gel Type

8 0 5 x 1 1 6 0 x 1 6 0 0 m m 1040x2800x1900800 45002050180014251219903

TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT

DP Electronics e.K(Deutsche Power Co. L imited) has a pol icy of continuous product development and improvement and therefore reserve the r ight to vary any information without pr ior notes.

ES60033 ES80033

>0.85 (with f i l ter)

600KV/540KW 800KV/720KW

945x1400x1900mm 1040x1640x1900 1100x3900x19503700 6400

70dB

INDUSTRIAL GRADE ONLINE DOUBLE CONVERSION UPS (Elektra Series)

Page 8: ELEKTRA SERIES - DP Electronics Deutsche Power | …...digital interactive technology. Up to eight Elektra units may be connected in parallel, allowing you to customize and adapt our

Deutsc

he Pow

erDP ELECTRONICS E.K (DEUTSCHE POWER CO., LIMITED)

Germany Head Office

DP electronics e.K (Deutsche Power Co., Limited) Klon, Germany.Phone: +49-221-26016266

Fax: +49-221-26016267Email: [email protected]

Hong Kong Office

RM 1701(057), 17/F, HeNan Building No90, Wan Chai, Hong Kong.Phone: +86-755-82610239

Fax: [email protected]