electrosurgical generator g400
TRANSCRIPT
Electrosurgical GeneratorG400
ELECTROSURGICAL GENERATOR G400Multifunctional High Frequency Surgery Generator for safe, easy andefficient cutting and coagulation. Built-in Touchscreen-Monitor with clear image of all neccessary information. Unit detects and identifies connected instruments automatically by the use of SDS-plugs. Large memory locations and different user configurations complete aversatile and compact system.
FEATURES:
• Detects and identifies connected instrument automatically by the use of SDS-plugs
• Powerstart System simplifies the beginning of cutting process
• Automatic power regulation• 105 different memory locations in
7 groups• Various output configuration of the
sockets available• Footswitch (optional)• Available with Argon and / or theRZeal
TOUCHSCREEN
Order-No. Description
700-350-405 2-Button-Footswitch, length: 5m
700-350-402 3-Button-Footswitch, length: 5m, quick access key
Order-No. Description
700-350-400 Electrosurgical Generator G400 230V
700-350-410 Electrosurgical Generator G400 110V
700-350-420 with Argon 230V
700-350-430 with Argon 110V
700-350-460 with theRZeal 230V
700-350-470 with theRZeal 110V
700-350-450 with theRZeal and Argon 110V
700-350-440 with theRZeal and Argon 240V
10“ Touchscreen Easy readable interfacedesign
Tiltable display to provideoptimal view from everyposition
Instrument detecting sockets
Order-No. Description
700-503-003 Cable, 5m
700-503-000 Neutral Electrode,single use, pack of 50pcs.
SDS CODED CABLES
Order-No. Description
700-500-453 Bipolar, 4.5 m
Order-No. Description
700-501-453 Monopolar, 4.5m
SDS Plug, pre-coded.G400 Unit identifies Urology automatically.
UROLOGY CABLE FOR BIPOLAR RESECTOSCOPES
Order-No. Description
700-500-453 Bipolar, 4.5m
Order-No. Description
700-501-453 Monopolar, 4.5m
Order-No. Description
253-501-453 Monopolar, 4.5m
CABLE FOR MONOPOLAR COAGULATION ELECTRODES
HYSTEROSCOPY
CABLE FOR BIPOLAR COAGULATION ELECTRODES
Order-No. Description
700-500-300 Bipolar, 3m
700-500-500 Bipolar, 5m
Order-No. Description
700-501-453 Monopolar, 4.5m
SDS Plug, pre-coded.G400 Unit identifies Hysteroscopy automatically.
CABLE FOR BIPOLAR RESECTOSCOPES
CABLE FOR MONOPOLAR RESECTOSCOPES
CABLE FOR MONOPOLAR RESECTOSCOPES
CABLE FOR MONOPOLAR COAGULATION ELECTRODES
Order-No. Description
700-500-300 Bipolar, 3m
700-500-500 Bipolar, 5m
Order-No. Description
700-501-301 Monopolar, 3m
SDS Plug, pre-coded.G400 Unit identifies Arthroscopy automatically.
ARTHROSCOPY
Order-No. Description
700-501-300 Monopolar, 3m
700-501-500 Monopolar, 5mSDS Plug, pre-coded.G400 Unit identifies Laparoscopy automatically.
LAPAROSCOPY
CABLE FOR BIPOLAR RESECTOSCOPES
CABLE FOR MONOPOLAR RESECTOSCOPES
CABLE FOR MONOPOLAR ELECTRODES
REGULAR CABLES
Order-No. Description
700-501-303 Monopolar Cable, 3m
700-501-503 Monopolar Cable, 5mRZ HF Unit Standard Plug
CABLE FOR MONOPOLAR COAGULATION ELECTRODES
RZ / Valleylab / Lamidey / EMC
LAPAROSCOPY / ENT / ARTHROSCOPYUROLOGY / HYSTEROSCOPY
Order-No. Description
700-351-031 Bipolar, flat-plug, 3m
700-351-051 Bipolar, flat-plug, 5m
Order-No. Description
700-300-203 Bipolar, 2-pin plug, 3m
700-300-205 Bipolar, 2-pin plug, 5m
Order-No. Description
253-400-603 Bipolar, 4.5m
Order-No. Description
700-501-045 Monopolar, 4.5m
CABLE FOR BIPOLAR RESECTOSCOPES
CABLE FOR MONOPOLAR RESECTOSCOPESAND MONOPOLAR COAGULATION ELECTRODES
RZ HF Unit Standard Plug
RZ / Valleylab / Lamidey / EMC
CABLE FOR BIPOLAR COAGULATION ELECTRODES
UROLOGY / HYSTEROSCOPY
Safety features
Class / Grade I/CF
Low-frequency leakage currents acc. to IEC 60601-1
High-frequency leakage currents acc. to IEC 60601-2-2
Generator operation frequency 333 kHz
Defibrillation impulse resistance acc. to EN 60601-1
NEM Systemneutral electrode control, optical indication 7 levels, required resistance < 240 Ω
ARGON*
Gas Type pure Argon 4.8 (99.999%) or higher
Inlet gas pressure 0.25 - 0.4 [MPa]
Gas outflow0.1 - 10l/min, regulated 0.1l/min in whole range
Pressure range reducer (0.4 MPa) on argon cylinder
theRZeal**
Vessel sealing system 9 effects / 300W
AutoStopoutomatic stop of sealing process after achieving the optimal effect
Monopolar Cutting
Mono Cut 9 effects / 350W
Precise Cut 9 effects / 50W
Mixed Cut 9 effects / 150W
Polipo Cut 9 levels
Papillo Cut 9 levels
Arthro Cut 9 levels
Uro Cut 9 levels
Hystero CutCut** 9 levels9 le
Argon Cut** 9 effects / 350W
Monopolar Coagulation
Soft Coag 9 effects / 200W
Forced Coag 9 effects / 200W
Spray Coag 80W
Hybrid Coag 9 effects / 200W
Standard Argon* 80W
Endo Argon* 40W
Pulse Argon* 40W
Uro Coagstero Cut** 9 levels le
Arthro Coag 9 levels
Hystero Coag 9 levels
Bipolar Cutting
Bi-Cut 9 effects / 120W
Uro Bi-Cut 9 levels
Arthro Bi-Cut 9 levels
Weight and Dimensions
Weight 12.2kg
Dimensions 495 x 415 x 225mm (LxWxH)
Bipolar Coagulation
Soft Bi-Coag9 effects / 120WAutoStart/AutoStop
Forced Bi-Coag 9 effects / 120W AutoStop
Uro Bi-Coag 9 levels
Arthro Bi-Coag 9 levels
Sciss Bi-Coag 9 levels
Power Supply
Supply Voltage 230V +/- 10% 50Hzor 110V +/- 10% 60 Hz
Rated power input 500W
TECHNICAL DATA
YouTube setup and operation Video on the RZ YouTube Channel:https://youtu.be/MhNz01LMn-k
* available only in Argon-Version** available only in TheRZeal + Argon Version
RZ Medizintechnik GmbHUnter Hasslen 20 D-78532 Tuttlingen
Phone: +49 (0)7462/9470-0Fax: +49 (0)7462/9470-50
© 07/2017 Copyright by RZ Medizintechnik GmbH · Unter Hasslen 20 · D-78532 Tuttlingen. All rights reserved. Modifications of technical specification or design are subject to change without prior notice.
Media Code Number: 021450