electronics-line.com do’s and dont’s - how to prevent troubles iconnect / commpact
TRANSCRIPT
electronics-line.com electronics-line.com
Do’s and Dont’s -How to Prevent Troubles
iConnect/ CommPact
electronics-line.com
iConnect – Installation and Location
• The location of the control panel is critical for the installation’s success.
˗ The location in basement or concrete room is not recommended!
˗ RF RSSI level (noises) should be as low as possible.To take into consideration the RF signal strength of the wireless devices
2
electronics-line.com
iConnect – Installation and Location
• Do not locate the control panel close to Electro-magnetic sources (computers, fax machine, Electrical cabinet, Routers and etc).
3
electronics-line.com
iConnect – Installation and Location
• In case of electric power outage for few days, back up battery becomes totally empty.
• Rarely, the battery becomes totally empty.• In order to wake the battery up, it’s required
to insert and remove the battery connector a few times (10-15 times) to the main board.
4
electronics-line.com
iConnect – Installation and Location
• Fuse for AC power and fuse for battery can be damaged because of lightning.
• Those fuses can be easily replaced.
5
electronics-line.com
The Wireless devices – Location and Installation
• Minimum of one meter between devices or between device to the control panel.
6
electronics-line.com
The Wireless devices – Location and Installation
• Do not locate the Wireless devices close to Electro-magnetic sources(computers, fax machine, Electrical cabinet, Routers and etc).
7
electronics-line.com
The Wireless devices – Location and Installation
• Wireless devices BatteriesDue to the occurrence of voltage delay in lithium batteries that have been in storage,the batteries may initially appear to be dead. In this case, leave the unit in Test mode for a few minutes OR press on the tamper switch a number of times until the battery voltage level is stabilized.
8
electronics-line.com
The Wireless devices – Location and Installation
• Battery - Date of production is something that installer must pay attention to.
• Battery with a date of production which is more than 2 years isn’t recommended for installation.
9
May of 2011
electronics-line.com
The Wireless devices – Location and Installation
• The Signal strength level of the wireless device, must be with level 5 and above.
• When installing the detector on the wall, make sure that the screw isn’t sticking out.
10
electronics-line.com
The Wireless devices – Location and Installation
• If there is a suspicion of transmissions’ loss from the device OR supervision loss event occurs in panel, radio test needs be performed.
• Every 8 seconds, signal will send to panel. Each signal will be heard by number of tones
11
electronics-line.com
The Wireless devices – Location and Installation
Why can’t the Wireless device be registered in the control panel?
1. The device had already been registered.2. The zone is defined as ‘Use Repeater’.3. The battery is empty.4. The battery is inverted.5. The back tamper of the device is opened.6. Noisy area (RF RSSI Level=9).7. The RF frequency is different (868/433MHz).
12
electronics-line.com
Curtain detector – EL2650XL
• Avoid placing the detector in an area exposed tosunlight coming in through the window.
• For night arming make sure that the user will keep a distance from the detector’s coverage:
13
electronics-line.com
Curtain detector – EL2650XL• By quickly reaching out the hand into the coverage
area and pulling it back, may cause a false alarm.• Distance from the window/wall: at least 5cm:
14
electronics-line.com
Magnetic Contact EL-2601
• The detector on the frameThe magnetic on the window
15
Wrong installation – Supervision loss may occur.Wrong installation – Supervision loss may occur.
electronics-line.com
Magnetic Contact EL-2601
• On massive steel frame, it is recommended to add a spacer to the detector .
16
electronics-line.com
PIR Motion detector - EL2645/EL2745
• Height: 1.80m - 2.20m.• PI version - To take into consideration the pets
and to install in appropriate place.
17
electronics-line.com
Communication Troubles
18Presentation name
Trouble MessageReason for the troubleSolution
No MessageAccount 1 Protocol[95112] ≠ IP interface[95113] ≠ LAN or GPRS
Protocol[95112] = IPInterface[95113] = LAN or GPRS
Device Trouble LAN/GPRS module
Communication module is faulty
Replace the module
Media Loss – LAN/GPRSNo internet connection- Check the cable network/SIM card.- SIM card with low signal - Check with the service provider
DHCP ErrorPanel doesn't get DHCP from the network
Check with the IT manager regarding the DHCP settings. If required insert the relevant parameters at address [95771], [95772] and [95773]
XML fail1.1.Problems at the service provider network2.2. Firewall3.3. Wrong parameters had been configured (IP address, CP ID, CP Password
1. Check with the service provider the connection2. Check that port 33000 is opened with the IT manager3. Check that the parameters are correct
Program Correct interface1.one or more of the interfaces (of accounts, RP, speed dials and service call) are configured with interface which doesn't exist
Change the interface/s of according to the insttaled module