electronic lock ‘multicode’ - nautasecurity · 2 general the lock operates with a numeric...

6
think safe USER INSTRUCTIONS Electronic lock ‘Multicode’

Upload: nguyennga

Post on 24-Jun-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

think safe

USER INSTRUCTIONSElectronic lock ‘Multicode’

2

GeneralThe lock operates with a numeric 6-digit or 7-digit code. Each key press is confirmed with an audio and light signal. After entry of a valid code a double signal follows. An invalid entry is followed by a long signal. After 10 seconds without entry, an already entered part of the code is cancelled.

Open in standard modeEnter code: i.e. 1-1-1-1-1-1Unlock door and open. If not opened within 3 seconds, the lock secures automatically.

Open in dual comboTwo users are required to open with dual combo. For example: 1-1-1-1-1-1 and 2-2-2-2-2-2unlock door and open. If not opened within 3 seconds, the lock secures automatically.

Open with time delayAfter code entry, time delay starts, recognizable on light signal flashes at two-second interval At the end of the delay period the open window starts, the light signal flashes and the lock beepsat 1-second interval alternately. To open the lock, a valid code has to be entered again during the open window. If the open window expires without the lock being opened, the lock issecured again with the time delay.

To Delete current action: press random key.To Extend delay time: enter valid code. The delay period will start again.

Open with time delay overrideEnter a code, the time delay will start, then enter code provided to user 9 (time delay overridecode). For example: user 1: 1-1-1-1-1-1 (time delay starts). user 9: 9-9-9-9-9-9. Unlock door and open. If not opened within 3 seconds, the lock secures automatically.

Change code (with safe door open!)Press and hold key “0” until double signal. The light remains on during the following actions.•Enter old code•Enter new code and repeat new code

For example: “0” till double signal and light stays on•old code 1-1-1-1-1-1 (double signal)•new code 9-8-7-6-5-4 (double signal)•new code 9-8-7-6-5-4 (double signal)

In case of entry errors (long signal ), the old code remains valid.

Activate silent alarmIn case of a hold up situation, a silent alarm can be sent by entering the last code digit +1.For example: valid Code 9-8-7-6-5-4, alarm will be sent by entering 9-8-7-6-5-5. This code works as a valid code.

User instructions electronic lock ‘Multicode’

3

think safe

GDK-v20042012

Activate userPress and hold key “1” until double signal. The light remains on during the following actions.1. Enter manager code2. Enter user ID 1-9 (only if more than 1 user is installed)3. Enter user code4. Repeat user code

For example: to activate user 1:“1” till double signal and light stays on1. Manager code 1-2-3-4-5-62. User ID 1 (only if more than 1 user is installed)3. User code 1-1-1-1-1-14. User code 1-1-1-1-1-1

Activate user in dual mode1. Enter user code2. Press and hold key “1” until double signal.3. Enter manager code4. Enter user ID 1-95. Enter user code and repeat user code

For example: activate user 2: user 1 is activated with: 1-1-1-1-1-1 and the managercode is 1-2-3-4-5-6.1. User code 1: 1-1-1-1-1-12. Press and hold key “1” until double signal3. Enter 1-2-3-4-5-64. Enter 2 5. Enter 2-2-2-2-2-2 and enter 2-2-2-2-2-2 again

Disable/enable users (not possible in dual mode!)Press and hold key “2” until double signal. The light remains on during the following actions.Enter manager code. All users are disabled. Repeat procedure to enable all users.

Delete usersPress and hold key “3” until double signal. The light remains on during the following actions.Enter manager code. Enter user ID. User is deleted.

For example: “3” till double signal and light stays on. 1. Manager code 1-2-3-4-5-62. User ID 1To activate user again please refer to function ‘activate user’. Please note that new user code differs from previous code.

US

ER

INS

TR

UC

TIO

NS

ELE

CT

RO

NIC

LOC

K “M

ULT

ICO

DE”

2

Time delay (max. 99 minutes) amd open window time (max. 19 minutes)Press and hold key “9” until double signal. The light remains on during the following actions.1. Enter manager code2. Enter time delay and open window time3. Repeat values

For example: “9” till double signal and light stays on1. Manager code 1-2-3-4-5-62. 2612 for 26 minutes time delay and 12 minutes open window.3. Repeat values Note: decreasing the time delay value can only be done in open window time. Increasing can be done at any time. If you want to delete the time delay, please repeat the above mentioned procedure and enter 0001 instead of 2612. (00 for Time delay and 01 for Open window)

Audit usersPress and hold key “7” until double signal. The light remains on during the following actions Listen to tone signals.1. Enter manager code2. Enter 1,2,3,4,5,6,7,8,9 and 0 to stop

•Double signal = User active with code•One signal = User active without code (or disabled)•Long signal = User not active

Questions / malfunctionsDo you have questions about your safe, the electronic lock or is there an unexpected malfunction? Please contact your local dealer.

User instructions electronic lock ‘Multicode’

3

think safe

GDK-v20042012

US

ER

INS

TR

UC

TIO

NS

ELE

CT

RO

NIC

LOC

K “M

ULT

ICO

DE”

Citysafe Wholesale [email protected] citysafe.co.uk

Unit 9, Southampton Trade ParkThird Avenue, HampshireSouthampton SO15 0LEUnited Kingdom

Hanzeweg 103771 NG Barneveld

The Netherlands

Nauta Security Storage [email protected] nautasecurity.com

Nauta [email protected] nauta.com