Portable ApplianceTestersPAT 400 seriesThree new PAT testers with full database functionality based onthe well received PAT300 series. The PAT 400 series introduces a

new level of convenience and speed to PAT testing usingon-board test results storage.

Testing to the latest edition of the Code of Practicefor the In-Service Inspection and Testing ofElectrical Equipment includes differential, touchand alternative or substitute earth leakage tests.

The PAT400 series offers sufficient memory for thetest results of 10,000 assets with the proven long duty

cycle, testing simplicity and speed of the PAT300 series.In use, the PAT400 series has a large bright colour

screen indentify test results and easynavigation through the menus.

The menus have been simplified to makeoperation faster. Five soft-keys give direct access

to frequently used functions making navigationthrough the menus quick and the tester more

productive, offering a greater return on investment.A new feature is the expert and novice modesmaking testing even faster for experienced user.

For corporate users, the PAT400 series now has anoptional security log-in for controlling access to testparameters and limits, and logging the active userwithin the results database.

The PAT400 series provides instant access to records inthe database and the data can be downloaded using astandard USB memory stick. For rapid data entry thePAT400 series has a full QWERTY keyboard, thishelping to reduce typing errors.

PAT410 perfect for those happy to bond test solely at 200 mA.The smallest, lightest of the PAT400 series weighs only 2.7 kg.

PAT420 offers bond testing at all three currents, 200 mA, 10 Aand 25 A as well as 230 V and 110 V operation. This tester is thechoice of those who are full-time industrial or commercial PATtesters.

PAT450 in addition to the three bond tests and 230 V and 110 Voperation this tester offers 1.5 kV and 3.0 kV flash testingmaking the perfect tool for hire and repair workshops.

20 PORTABLE APPLIANCE TESTERS

Special Features■ New Expert mode to speed up testing

■ New Secure user log-in option

■ Vast on-board memory to keep you on the joblonger

■ Continuous operation, no need to stop andwait for the tester to cool down

■ Instant re-start as you move from room toroom

■ Soft keys to speed you through the testingprocess

■ Automatic asset number generation

■ Quick test for instant access to single testfunctions

■ Most productive tester in its class

Nick
Rectangle

1000-767 415 V 4 pin adaptorlead to BS1363

1000-770 415 V 5 pin adaptorlead to BS1363 (16 A)

6220-639 110 V extension lead adaptor

PORTABLE APPLIANCE TESTERS 21

MFT1700 Series

MFT withcertification

Electricaltest kits

Part Pkits

Combinedloop & RCD

testers

Insulationtesters

Industrialinsulation

testers

Looptesters

RCDtesters

PATs

Certificationsoftware

Metertest box

Voltagedetector,

Solar tester

Accessories

Clamp andmultimeters

Specialistclampmeter,Earth testers

StructuredCable

Certifiers

Prices

■ 10,000 asset on-board data storage ■ Large easy to ready colour screen ■ Instant re-start ■ 25 A, 10 A and 200 mA “soft” bond test■ Test lead null ■ Repeated high current bond testing possible ■ Insulation testing at 250 V and 500 V ■ Functional VA load test for 110 V and 230 V appliances■ Extension and IEC lead testing including polarity, earth

continuity, L-N continuity and L-N-E insulation ■ Standard differential leakage test plus

■ Protective conductor or touch current leakage test ■ Substitute earth leakage test at 40 V a.c.

■ Simple RCD test or full 30 mA RCD testing ½ x I, I, 5 x I■ Integral fuse checker

For PAT420 Business in a box see page 19

Supply230 V ■ ■ ■

110 V ■ ■

Supply measurement ■ ■ ■

Earth bond/continuity200 mA ■ ■ ■

10 A ■ ■

25 A ■ ■

Bond lead null ■ ■ ■

Insulation test250 V ■ ■ ■

500 V ■ ■ ■

Alternative leakage testsSubstitute ■ ■ ■

Differential ■ ■ ■

Touch current ■ ■ ■

Functional testVA measurement ■ ■ ■

Extension lead testsEarth bond ■ ■ ■

Insulation ■ ■ ■

Polarity ■ ■ ■

Portable RCD tests ■ ■ ■

Flash test1.5 kV and 3.0 kV ■

Other features Low-profile light weight ■

110 V test connection ■ ■

Auto test routine ■ ■ ■

Manual testing ■ ■ ■

Configurable tests times ■ ■ ■

Selectable pass limits ■ ■ ■

Fuse check ■ ■ ■

Large colour display ■ ■ ■

Data handling10,000 record on-board storage ■ ■ ■

Download to USB memory stick ■ ■ ■

PowerSuite compatible ■ ■ ■

Supplied accessoriesCarry case with lead storage pouch ■ ■ ■

Combined continuity, earth bond and insulation test lead ■ ■ ■

Red extension lead adaptor ■ ■ ■

Flash test lead ■

FREE calibration certificate ■ ■ ■

PAT410 PAT420 PAT450

PAT400 series accessories

1000-766 110 V mains lead adaptor

1001-047 Barcode scanner

1001-227 Faillabel roll of 1000

1000-971Pass labelroll of 1000

1001-046 Pass / failbarcode printer

Scan with your smartphoneto see a demonstration ofthe PAT400 series