electric headlight starter (ignition device)
DESCRIPTION
Dynamic headlight range control. The start-up characterisation has 4 phases 1. Ignition through high voltage impulse ( a few ms, about 12 to 20 kV ). 2. Starting light ( about 15 % ): Limitation of lamp's current and output to about 2.6 A or 75 Watt 3. Light changes colour - PowerPoint PPT PresentationTRANSCRIPT
Service TrainingK-VK-36 2
Electric headlight starter(ignition device)
The start-up characterisation has 4 phases
1. Ignition through high voltage impulse ( a few ms, about 12 to 20 kV ).2. Starting light ( about 15 % ): Limitation of lamp's current and output to about 2.6 A or 75 Watt3. Light changes colour4. Continuous operation ( about 35 Watt ): The electric arc attains its specification which is stabilised by the headlight starter (ballast). (Alternating current with a frequency of 400 Hz)
12 kV
2.6 A/75W
35 W
* The combustion chamber is a pea-sized glass cylinder filled with xenon gas and metallic halide salts. ( pressure about 100 bar )* Electric arc temperature about 700° C* 250 % more light efficient* 5 times the life span* Can be renewed only by trained personnel
ConverterRegulation range
Dynamic headlight range controlDynamic headlight range control
Service TrainingK-VK-36 3
20
19
15
16
Terminal 15Terminal 31Terminal 65b
V signalK wire
Failure warning lightin estate ( Audi only )
G 78
G 76 V 49 right
M
V 48 leftFunctional diagramHeadlight range control
3524
17 10 9
13 14 11 12
1
786
M
Headlight range control CUon left in
luggage compartment
J 431
CAN ( to be used later )
6
2
4
3
3
4
2
6
Dynamic headlight range controlDynamic headlight range control
Service TrainingK-VK-36 4
Vehicle attitude senderG 76 / G 78
Design NN
S
S
Angle of rotation 70°
4.5
2.5
0.50 V
Contactless attitude sender operating on Hall principleThe senders are identical to those of the static headlight range control( see also Trainer Information Audi A6 )
Ring magnet
Stator
Hall sender
High magnetic field density
Low magnetic field density
Dynamic headlight range controlDynamic headlight range control
Service TrainingK-VK-36 5
Headlight range control self-diagnosis
Address word 55
Coding 00007 for front wheel drive00008 for four-wheel drive
Final control diagnosis Lower/raise headlights
Measured value block Channel 001 1 = Voltage supply terminal 15 ( in Volt )2 = Light switch terminal 56b (light on/off )3 = Speed in km per hour4 = Vehicle acceleration in m/s²
Channel 002 1 = Front attitude sender in Volt ( 1.57 to 3.45 Volt )2 = Rear attitude sender in Volt ( 1.57 to 4.5 Volt )3 = Step motor actuation in % ( indicates what percent of the spindle is advanced from the zero position )4 = Time constant in seconds ( time required for 63 % of the adjustment to occur )
Basic setting Channel 01 Regulating mode is switched off Channel 02 Control unit learns the adjusted position
as regulation position
Dynamic headlight range controlDynamic headlight range control
Service TrainingK-VK-36 6
55 Headlight range control4B0 907 357CDynamic HRC D03
7
Voltage supply terminal 15
Light switch off/on
Vehicle speed
Vehicle acceleration in m/s2
12.1 V
0 / 1
0 km/h
0.00- 7.00 m/s2
Coding = 7 7 Front wheel drive
8 8 Four-wheel drive
1
Vehicle self-diagnosis
08 - Read measured value block
Read measured value block
Basic setting
Displaygroup
Coding 7Dealership number 1317
Service TrainingK-VK-36 7
55 Headlight range control4B0 907 357CDynamic HRC D03
7
Front vehicle attitude sender (1.57 to 3.45 V )
Step motor actuation in % ( 0 to 100% ) *
Time constant in seconds ( 0 to 2 seconds ) **
3.1 V
2.3 V
74 %
0.03 s
* indicates what percent of the spindle is advanced from zero postion of step motor
** indicates time required for headlights to attain 63% of their adjustment
2
Rear vehicle attitude sender (1.57 to 4.50 V )
Vehicle self-diagnosis
08 - Read measured value block
Read measured value block
Basic setting
Displaygroup
Coding 7Dealership number 1317
Service TrainingK-VK-36 8
55 Headlight range control4B0 907 357CDynamic HRC D03
7
12.1 V
0 / 1
0 km/h
0.00- 7.00 m/s2
Adjusting headlightsAdjusting headlights
1
For basic settingbasic setting, leave lights on and engine
running
For basic settingbasic setting, leave lights on and engine
running
Vehicle self-diagnosis
03 - Final control diagnosis
Read measured value block
Basic setting
Displaygroup
Coding 7Dealership number 1317
Service TrainingK-VK-36 9
55 Headlight range control4B0 907 357CDynamic HRC D03
7
3.1 V
2.3 V
74 %
0.03 s
2
For basic settingbasic setting, leave lights on and engine
running
For basic settingbasic setting, leave lights on and engine
running
Regulation position being learnt
Regulation position being learnt
Vehicle self-diagnosis
03 - Final control diagnosis
Read measured value block
Basic setting
Displaygroup
Coding 7Dealership number 1317
Service TrainingK-VK-36 10
55 Headlight range control4B0 907 357CDynamic HRC D03
7
3
Headlights will be lowered
Headlights will be raised
Signal wire to combi-instrument
Vehicle self-diagnosis
03 - Final control diagnosis
Read measured value block
Basic setting
Displaygroup
Coding 7Dealership number 1317