SINCE 1989Electric Actuated Flow Control ValvesLIAONING SJD TRADING CO. LTD.

Annual Exported Sales Revenue

6/30/2016 [email protected]

Main Products

3730 Electro-Hydraulic Actuator

3610 Rotary Stroke Explosion Proof Actuator

3720 Non-invasive Electric Actuator

6/30/2016 [email protected]

3730 Electro-Hydraulic Actuator

Rotary Stem Motion Type

Max. Output: 120000Nm

Power Source: 380VAC

Max Angle: 90°

Eviroment Temp.: -10℃~+60℃

Deadband: 0.6%

Positioning accuracy: <1.0%

Repeatability: <1.0%

Enclosure type: ExdllBT4 IP65

6/30/2016 [email protected]

3730 Electro-Hydraulic Actuator

Swing cylinder drive, compact structure, stronger output torque

Automatically action memory function, cumulating time and numbers for control and maintenance.

Non-invasive remote control operation, manually setting parameter without opening enclosure

6/30/2016 [email protected]

3610 Explosion Proof Actuator

6/30/2016 [email protected]

Stem Motion Type: Linear and Rotary

Max. Output: 16000Nm & 2500Nm

Power Source: 220VAC

Control Signal: 4-20mADC/1-5VDC

Deadband: 0.8%

Positioning accuracy: ≤1.0%

Response Time: ≤0.8S

Environment Rating: IP55

3730 Electro-Hydraulic Actuator

Widely used automation and control

6/30/2016 [email protected]

Reliability, easy operation and maintenance

Enclosure type: ExdllBT4

3720 Non-invasive Electric Actuator

6/30/2016 [email protected]

Stem Motion Type: Linear and Rotary

Max. Output: 10000Nm & 600Nm

Power Source: 220VAC

Control Signal: 4-20mADC

Deadband: 0.8%

Positioning accuracy: ≤1.0%

Response Time: ≤0.8S

Environment Rating: IP65

3720 Non-invasive Electric Actuator

Advanced hybrid integrated circuits

Output point feedback, self-diagnostic and alarm functions

Non-invasive remote control operation, manually setting parameter without opening enclosure

6/30/2016 [email protected]

Order Notice-necessary

6/30/2016 [email protected]

Actuator type (If unclear, provide: action mode, output power

or way of control)

Supply Voltage

Stroke

Installation place and temperature (Temperature is lower

than -10℃, “heating element” shall be noted; when lower

than -30℃, relative insulation protection shall be added

according to the circumstance.)

Order Notice-support

6/30/2016 [email protected]

Related Valve Type

Pipe Installation Direction

Contact Information

Contact: Susan Yao LIAONING SJD TRADING CO., LTD.Email: [email protected]://www.valve4s.com/en/https://plus.google.com/u/0/105474428703289057133https://www.facebook.com/valvepipefittinghttps://www.linkedin.com/company/liaoning-sjd-trading-co--ltd-https://www.pinterest.com/oilandgasvalve/

6/30/2016 [email protected]

THANKS

6/30/2016 [email protected]