Page 1: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 1

601-000149 Rev. C Arch. 5389 16/02/2017

User Manual

Coaxial Adapter card

EK-CDP/2

Page 2: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 2

601-000149 Rev. C Arch. 5389 16/02/2017

The present design is property of Eurotek s.r.l. and is protected by Copyright.

Its reproduction, distribution and disclosure to third-parties without written authorisation is forbidden

Every reproduction, re-distribution or disclosure without prior written authorisation

is expressly forbidden by the law and can lead to serious civil and penal sanctions.

Page 3: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 3

601-000149 Rev. C Arch. 5389 16/02/2017

Warning!

The socket utilized for the unit supply must have the appropriate ground conductor.

The connection of the unit , to a socket without the ground conductor, will make the whole

equipment dangerous for people safety.

About the repairing of the units please refer to specialized personnel only .

Inside the devices there are voltages which could be dangerous to people.

Before opening the cover switch off the unit, disconnect the connection and

the supply cables.

In case of electrical shock please follow the instructions

of first aid listed on page 4

Substitute the fuses interrupted with others of the same type and voltage.

The waste disposal of the devices must be executed in the respect of the enforced laws in

the country uses.

Eurotek not assumed responsibility for waste disposal in contrast with enforced laws.

LIFE SUPPORT APPLICATIONS.

Eurotek’s products are not designed for use as critical components in life support devices or system

without the express written approval of the Eurotek S.r.l. As used herein.

- Life support devices or system are devices or system which, (a) are intended for surgical

implant into the body, or (b) support or sustain life, and whose failure to perform, when

properly used in accordance with instructions for use provided in the labeling, can be

reasonably expected to result in a significant injury to the user.

- A critical component is any component of a life support device or system whose failure to

perform can be reasonably expected to cause the failure of the life support device or system,

or to affect its safety or effectiveness.

The information given in this documentation could have variations without forewarning.

The firm Eurotek S.r.l. does not give any guaranty about this documentation.

The firm Eurotek S.r.l. does not consider itself responsible for possible mistakes which could be

found in this documentation.

Page 4: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 4

601-000149 Rev. C Arch. 5389 16/02/2017

First aid: artificial breathing(mouth to mouth)

1

In case of electric shock you have to ensure the first aids to

the patient, but to do this you have to consider two very

important things:

- interrupt immediately the electric circuit;

- if the circuit has not been interrupted, do not touch

the patient with bare hands;

After doing this, without delay contact the nearest mobile

unit of first aid and practice to the patient, in case of loss of

consciousness, the breathing mouth to mouth as described

below.

2

Put the patient lying on his back with the arms parallel to

the body, ensure that he does not have the breathing tracts

obstructed (chewing-gum, dental prosthesis, etc.),

otherwise set him free from foreign bodies.

Kneel near the patient’s head and putting a hand under his

neck, incline as possible his/her head backwards.

3

Going on with keeping the patient’s head inclined with one

hand, use the other one to occlude the nostrils, if you are

going to practise the breathing through the oral cavity, or

occlude the mouth if you want to do it through the nasal

cavity.

While doing this begin the auto-oxygenation, with deep

breathing.

Then practice the artificial breathing blowing in the chosen

cavity beginning with ten expirations each minute to go on

them with twelve and fifteen.

4

During the breathing procedure you have to control that the

patient’s chest dilates, otherwise change cavity where to

blow the air because the previous one could be obstructed.

5 Do not ever stop the artificial breathing until the patient

has recovered or the first aid unit has come.

Page 5: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 5

601-000149 Rev. C Arch. 5389 16/02/2017

INDEX

INDEX ............................................................................................................................................... 5

1. GENERAL DESCRIPTION ............................................................................................. 6

2. BOARD PANEL .................................................................................................................... 7

2.1 BOARD PANEL REPRESENTATION ........................................................................................7

2.2 BOARD PANEL DESCRIPTION ................................................................................................7

3. BOARD MENU ...................................................................................................................... 8

3.1 MENU REPRESENTATION .....................................................................................................8

3.2 MENU DESCRIPTION AND KEYBOARD GUIDE ......................................................9

4. REMOTE CONTROL ....................................................................................................... 14

Page 6: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 6

601-000149 Rev. C Arch. 5389 16/02/2017

1. GENERAL DESCRIPTION

The EK-CDP/2 board allows to connect the EK-MFR/1 or EK-MFR/2 unit to the SHF parts inserted

into the Eurotek Out Door Units (ODU)* and allows the use of every frequency band, at present,

available.

Thanks to the use of two N type connectors every single board can control simultaneously two

external sections (ODU) in completely independent way one from the other.

We can therefore connect simultaneously a transmission section and receiver section in order to

obtain a bi-directional connection simply using only one Mo-demodulator for every single

emplacements.

The board has also two auxiliary IF 70 MHz input that can be used as possible reserve signals in

both transmission and receiver sites.

From the menu of the EK-MFR/1 or EK-MFR/2 we will be able to read several information on the

operation of the ODU (OUT DOOR UNIT) like for example the power transmitted, the received

field or if there are active alarms. Through the keyboard we will always to decide which ODU we

can qualify, send to the transmitting ODU the auxiliary IF eventually at disposal at the input of the

board (IF IN TX), set the manual control gain of conversion gain, receive the signal by the ODU

receiver or choose an external IF (IF OUT RX) and in presence of ODU synthesized change the

channel of the radio link.

The board is moreover equipped with a protection circuit that in present of a short circuit on the

coaxial cable or in the ODU , to disable the power supply in order to protect the board from ulterior

damaging.

*The ODU models that are supported by the EK-CDP/2 board are:

TRANSMITTER VERSION

A4D-ExT/1 (single-channel)

A4D-ESxT/1 (multi-channel)

x = frequency (GHz)

RECEIVER VERSION

A4D-ExR/1 (single-channel)

A4D-ESxR/1 (multi-channel)

x = frequency (GHz)

The model version is reported on the Eurotek label

Page 7: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 7

601-000149 Rev. C Arch. 5389 16/02/2017

2. BOARD PANEL

2.1 BOARD PANEL REPRESENTATION

2.2 BOARD PANEL DESCRIPTION

A) N type connector (connected with the TX ODU).

B) IF frequency transmission input connector.

C) IF frequency received input connector.

D) N type connector (connected with the RX ODU).

E) No function.

F) Yellow led: indicates, if it is on, that the IF signal to transmit, present on the BNC connector

(B), is selected.

Page 8: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 8

601-000149 Rev. C Arch. 5389 16/02/2017

3. BOARD MENU

3.1 MENU REPRESENTATION

The complete menu of the EK-CDP/2 board is reported below:

Variable name Variable number

EK-CDP/2 1

>Status

>>ODU Rx Model 3

>>ODU Tx Model 4

>>Power Rx 5

>>Power Tx 6

>>Rx Alarm 7

>>Tx Alarm 8

>>Idu Alarm 9

>>Rx Volt o/p 10

>>Tx Volt o/p 11

>>Board Temp 12

>>ODU RX Temp 13

>>ODU TX Temp 14

>ODU RX Set

>>Ch Rx 15

>>Freq Rx 16

>>Enable Rx 17

>>IF BW 18

>>Rx 19

>ODU TX Set

>>Ch Tx 20

>>Freq Tx 21

>>Power Out 22

>>Enable Tx 23

>>IF2 Tx 24

>>Cable Length 25

>Revision

>>DSP 26

>>FPGA 27

>>CPLD 28

>>RamDisk 29

Page 9: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 9

601-000149 Rev. C Arch. 5389 16/02/2017

3.2 MENU DESCRIPTION AND KEYBOARD GUIDE

The user can enter every menu and sub-menu using the “explore menu” key to set the value of any

variables, using the “modify variable” key and to confirm the modify, pressing the “enter” key (EK-

MFR/1 pr EK-MFR/2 user ‘s handbook, front panel description paragraph).

>Status

>>ODU Rx Model

The box displays the receiver ODU Model connected to the EK-CDP/2 board.

NOTE: the display return one of the following value:

EK-DCT/n where n is the frequency number (5,6,10….etc).

>>ODU Tx Model

The box displays the transmitter ODU Model connected to the EK-CDP/2 board.

NOTE: the display return one of the following value:

EK-UCT/n where n is the frequency number (5,6,10….etc)

>>Power Rx

The user can read the power rx level of the EK-DCT/n with the relative unit of

measurement. The value of this parameter can be included between –127dBm and

–10dBm.

>>Power Tx

It is possible to read the power tx level of the EK-UCT/n. The limits of this parameter

can be included between –40dB and +1dB with a step of 0.1dB.

>>Rx Alarm

Rx Alarm supplies information about the EK-DCT/n revealed alarm. There are

different alarm condition reported below in according with the priority:

Rxvolt => The EK-DCT/n power supply is out of limit (25V<Vcc<29V)

FDMlev => The carrier of the EK-DCT/n receiver telemetry data is missing.

FDMdat => The carrier of the EK-DCT/n receiver telemetry data is present but is

not moduleted.

FDMerr => FDM receiver telemetry data error.

FDMcks => Checksum error on the FDM receiver telemetry data.

Rxtemp => The EK-DCT/n temperature is out of limits (-30°C<Temp<+80°C)

PLL => the PLL of the EK-DCT/n is unlock.

No => no alarm, normal working condition.

>>Idu Alarm

Only for EK-ST/4 and EK-ST/6 system.

>>Tx Alarm

Tx Alarm supplies information about the EK-UCT/n revealed alarm. There are

different alarm condition reported below in according with the priority:

Page 10: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 10

601-000149 Rev. C Arch. 5389 16/02/2017

Txvolt => The EK-UCT/n power supply is out of limit (25V<Vcc<29V)

FDMlev => The carrier of the EK-UCT/n receiver telemetry data is missing.

FDMdat => The carrier of the EK-UCT/n receiver telemetry data is present but is

not moduleted.

FDMerr => FDM receiver telemetry data error.

FDMcks => Checksum error on the FDM receiver telemetry data.

Rxtemp => The EK-UCT/n temperature is out of limits (-30°C<Temp<+80°C)

PLL => the PLL of the EK-UCT/n is unlock.

No => no alarm, normal working condition.

>>Rx Volt o/p

The user can read the value of the voltage on the receiver cable. This value can be

included between a minimum value of 0 Volt and a maximum value of 30 Volt.

>>Tx Volt o/p

The user can read the value of the voltage on the transmitter cable. This value can be

included between a minimum value of 0 Volt and a maximum value of 30 Volt.

>>ODU RX Temp

Allows to read the ODU receiver temperature. The value is reported in °C.

>>ODU TX Temp

Allows to read the ODU transmitter temperature. The value is reported in °C

>>Board Temp

The Board Temp menu allows to read the temperature of the board.

>ODU RX Set

>>Ch Rx

NOT AVAILABLE

>>Freq Rx

It is possible to set the receiver frequency value [MHz] with a 100 kHz step.

>>Enable Rx

This menu allows to enable the receiving ODU (out door unit). If the variable “yes”

is set, the ODU is enabled, while if the variable “no” is set, the ODU is disabled.

>>IF BW

It is possible to set the receiver IF bandwidth in respect of ODU characteristics.

>>Rx

The Rx menu allows to set the gain control of the board. There are two possibilities:

“agc”, allows an automatic gain control while “mgc” allows a manual gain control.

Page 11: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 11

601-000149 Rev. C Arch. 5389 16/02/2017

>ODU TX Set

>>Ch Tx

NOT AVAILABLE.

>>Freq Tx

It is possible to set the transmitter frequency value [MHz] with a 100 kHz step.

>>Power Out

Allows to set the ODU output power. The software loaded in the transmitter board

inserted in the ODU regulates the gain in according with the output power set.

(automatic gain control).

>>Enable Tx

This menu allows to enable the transmitting ODU (out door unit). If the variable

“Yes” is set, the ODU is enabled, while if the variable “No” is set, the ODU is

disabled.

>>IF2 Tx

It is possible to transmit the IF frequency present on the input board when the

variable “Yes” is on. This procedure is disabled if the variable “No” is selected When

the “Yes” value is active the yellow led located on the board panel (board panel

description, F) is light.

>>Cable Length

NOT AVAILABLE.

>Revision

This menu allows to read the software revision implemented on the programmable devices of the

board. The software configuration of the board is realized to obtain the release of the following

programmable devices (DSP, FPGA, CPLD, RamDisk).

The release version of the FPGA is not available because the device is not present on the board.

>>DSP

It is possible to read the software release implemented on the DSP device, on the EK-

MFR/1 display.

>>FPGA

The software release does not exist.

>>CPLD

It is possible to read the software release implemented on the CPLD device, on the

EK-MFR/1 display.

>>RamDisk

It is possible to read the software release implemented on the RamDisk device, on the

EK-MFR/1 display.

Page 12: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 12

601-000149 Rev. C Arch. 5389 16/02/2017

The example below explains how to set the frequency value of the gain control of the board (Rx

menu).

When the EK-MFR/1 or EK-MFR/2 is configured (EK-MFR/1 or EK-MFR/2 user ‘s handbook,

display and keyboard description paragraph), it is possible, using the “explore menu” keys (EK-

MFR/1 or EK-MFR/2 user ‘s handbook, front panel description paragraph), to see the boards that

are inserted in the system. We suppose to insert the EK-CDP/2 board in the slot number three. The

following view appears on the display of the EK-MFR/1 or EK-MFR/2:

Pressing the “enter” key, (EK-MFR/1 or EK-MFR/2 user ‘s handbook, front panel description

paragraph) the user can enter to the EK-CDP/2 menu and using the “explore menu” keys it is

possible to see the four main menu of the board: Status, ODU RX Set, ODU TX Set and Revision.

Page 13: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 13

601-000149 Rev. C Arch. 5389 16/02/2017

When the ODU RX Set menu is selected (above view), pressing the “enter” key it is possible to

enter in the sub-menu of the ODU RX Set menu and, using the “explore menu” keys, to run until the

Rx menu as follow:

Entering in the Rx menu, it is possible to see the actual value of the board gain control (in the above

view: agc). To change the value, push the “enter” key first, with the “modifying variable” keys it is

possible to set the new value (in the below view: mgc) and confirm it pressing again the “enter” key.

If, after the change, the “escape” key (EK-MFR/1 or EK-MFR/2 user ‘s handbook, front panel

description paragraph) is pushed, the display returns the previous value.

Page 14: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 14

601-000149 Rev. C Arch. 5389 16/02/2017

4. REMOTE CONTROL

The board can be controlled using two different ways:

Eurotek MST, an application that permits to manage and monitor all the board functionalities (Parameter settings, Internal connections, Log analysis, Software upgrade,

etc…), for more information see the Eurotek MST user manual.

Web Pages, using a standard web browser it is possible to see the web pages showing all the board parameters (see EK-MFR/2 user manual, web interface chapter), with limited

functionalities respect to the Eurotek MST.

Page 15: EK-CDP/2 - Eurotek · 2020-03-09 · EK-CDP/2 3 601-000149 Rev. C Arch. 5389 16/02/2017 Warning! The socket utilized for the unit supply must have the appropriate ground conductor

EK-CDP/2 15

601-000149 Rev. C Arch. 5389 16/02/2017

Eurotek S.r.l. c/o Parco Scientifico Tecnologico e delle

Telecomunicazioni in Valle Scrivia

Strada Comunale Savonesa, 9

15050 RIVALTA SCRIVIA (AL)

ITALY

tel. +39 (0)131 860205 r.a. fax +39 (0)131 860993

http://www.eurotektel.com

e-mail: [email protected]